“Scanning transmission electron microscopy under controlled low-pressure atmospheres”. Leuthner GT, Hummel S, Mangler C, Pennycook TJ, Susi T, Meyer JC, Kotakoski J, Ultramicroscopy 203, 76 (2019). http://doi.org/10.1016/J.ULTRAMIC.2019.02.002
Abstract: Transmission electron microscopy (TEM) is carried out in vacuum to minimize the interaction of the imaging electrons with gas molecules while passing through the microscope column. Nevertheless, in typical devices, the pressure remains at 10(-7) mbar or above, providing a large number of gas molecules for the electron beam to crack, which can lead to structural changes in the sample. Here, we describe experiments carried out in a modified scanning TEM (STEM) instrument, based on the Nion UltraSTEM 100. In this instrument, the base pressure at the sample is around 2 x 10(-10 )mbar, and can be varied up to 10(-6) mbar through introduction of gases directly into the objective area while maintaining atomic resolution imaging conditions. We show that air leaked into the microscope column during the experiment is efficient in cleaning graphene samples from contamination, but ineffective in damaging the pristine lattice. Our experiments also show that exposure to O(2 )and H2O lead to a similar result, oxygen providing an etching effect nearly twice as efficient as water, presumably due to the two 0 atoms per molecule. H(2 )and N-2 environments have no influence on etching. These results show that the residual gas environment in typical TEM instruments can have a large influence on the observations, and show that chemical etching of carbon-based structures can be effectively carried out with oxygen.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 4
DOI: 10.1016/J.ULTRAMIC.2019.02.002
|
|
|
“Evaluation of different rectangular scan strategies for STEM imaging”. Velazco A, Nord M, Béché, A, Verbeeck J, Ultramicroscopy , 113021 (2020). http://doi.org/10.1016/j.ultramic.2020.113021
Abstract: STEM imaging is typically performed by raster scanning a focused electron probe over a sample. Here we investigate and compare three different scan patterns, making use of a programmable scan engine that allows to arbitrarily set the sequence of probe positions that are consecutively visited on the sample. We compare the typical raster scan with a so-called ‘snake’ pattern where the scan direction is reversed after each row and a novel Hilbert scan pattern that changes scan direction rapidly and provides an homogeneous treatment of both scan directions. We experimentally evaluate the imaging performance on a single crystal test sample by varying dwell time and evaluating behaviour with respect to sample drift. We demonstrate the ability of the Hilbert scan pattern to more faithfully represent the high frequency content of the image in the presence of sample drift. It is also shown that Hilbert scanning provides reduced bias when measuring lattice parameters from the obtained scanned images while maintaining similar precision in both scan directions which is especially important when e.g. performing strain analysis. Compared to raster scanning with flyback correction, both snake and Hilbert scanning benefit from dose reduction as only small probe movement steps occur.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.2
Times cited: 13
DOI: 10.1016/j.ultramic.2020.113021
|
|
|
“Atom column detection from simultaneously acquired ABF and ADF STEM images”. Fatermans J, den Dekker Aj, Müller-Caspary K, Gauquelin N, Verbeeck J, Van Aert S, Ultramicroscopy 219, 113046 (2020). http://doi.org/10.1016/j.ultramic.2020.113046
Abstract: In electron microscopy, the maximum a posteriori (MAP) probability rule has been introduced as a tool to determine the most probable atomic structure from high-resolution annular dark-field (ADF) scanning transmission electron microscopy (STEM) images exhibiting low contrast-to-noise ratio (CNR). Besides ADF imaging, STEM can also be applied in the annular bright-field (ABF) regime. The ABF STEM mode allows to directly visualize light-element atomic columns in the presence of heavy columns. Typically, light-element nanomaterials are sensitive to the electron beam, limiting the incoming electron dose in order to avoid beam damage and leading to images exhibiting low CNR. Therefore, it is of interest to apply the MAP probability rule not only to ADF STEM images, but to ABF STEM images as well. In this work, the methodology of the MAP rule, which combines statistical parameter estimation theory and model-order selection, is extended to be applied to simultaneously acquired ABF and ADF STEM images. For this, an extension of the commonly used parametric models in STEM is proposed. Hereby, the effect of specimen tilt has been taken into account, since small tilts from the crystal zone axis affect, especially, ABF STEM intensities. Using simulations as well as experimental data, it is shown that the proposed methodology can be successfully used to detect light elements in the presence of heavy elements.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.2
Times cited: 9
DOI: 10.1016/j.ultramic.2020.113046
|
|
|
“HAADF-STEM block-scanning strategy for local measurement of strain at the nanoscale”. Prabhakara V, Jannis D, Guzzinati G, Béché, A, Bender H, Verbeeck J, Ultramicroscopy 219, 113099 (2020). http://doi.org/10.1016/j.ultramic.2020.113099
Abstract: Lattice strain measurement of nanoscale semiconductor devices is crucial for the semiconductor industry as strain substantially improves the electrical performance of transistors. High resolution scanning transmission electron microscopy (HR-STEM) imaging is an excellent tool that provides spatial resolution at the atomic scale and strain information by applying Geometric Phase Analysis or image fitting procedures. However, HR-STEM images regularly suffer from scanning distortions and sample drift during image acquisition. In this paper, we propose a new scanning strategy that drastically reduces artefacts due to drift and scanning distortion, along with extending the field of view. It consists of the acquisition of a series of independent small subimages containing an atomic resolution image of the local lattice. All subimages are then analysed individually for strain by fitting a nonlinear model to the lattice images. The method allows flexible tuning of spatial resolution and the field of view within the limits of the dynamic range of the scan engine while maintaining atomic resolution sampling within the subimages. The obtained experimental strain maps are quantitatively benchmarked against the Bessel diffraction technique. We demonstrate that the proposed scanning strategy approaches the performance of the diffraction technique while having the advantage that it does not require specialized diffraction cameras.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.2
Times cited: 4
DOI: 10.1016/j.ultramic.2020.113099
|
|
|
“Fast versus conventional HAADF-STEM tomography of nanoparticles: advantages and challenges”. Vanrompay H, Skorikov A, Bladt E, Béché, A, Freitag B, Verbeeck J, Bals S, Ultramicroscopy 221, 113191 (2021). http://doi.org/10.1016/j.ultramic.2020.113191
Abstract: HAADF-STEM tomography is a widely used experimental technique for analyzing nanometer-scale crystalline structures of a large variety of materials in three dimensions. Unfortunately, the acquisition of conventional HAADF-STEM tilt series can easily take up one hour or more, depending on the complexity of the experiment. It is therefore far from straightforward to investigate samples that do not withstand long acquisition or to acquire large amounts of tilt series during a single TEM experiment. The latter would lead to the ability to obtain statistically meaningful 3D data, or to perform in situ 3D characterizations with a much shorter time resolution. Various HAADF-STEM acquisition strategies have been proposed to accelerate the tomographic acquisition and reduce the required electron dose. These methods include tilting the holder continuously while acquiring a projection “movie” and a hybrid, incremental, methodology which combines the benefits of the conventional and continuous technique. However, until now an experimental evaluation has been lacking. In this paper, the different acquisition strategies will be experimentally compared in terms of speed, resolution and electron dose. This evaluation will be performed based on experimental tilt series acquired for various metallic nanoparticles with different shapes and sizes. We discuss the data processing involved with the fast HAADF-STEM tilt series and provide a general guideline when which acquisition strategy should be preferentially used.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 15
DOI: 10.1016/j.ultramic.2020.113191
|
|
|
“Hidden Markov model for atom-counting from sequential ADF STEM images: Methodology, possibilities and limitations”. De wael A, De Backer A, Van Aert S, Ultramicroscopy 219, 113131 (2020). http://doi.org/10.1016/j.ultramic.2020.113131
Abstract: We present a quantitative method which allows us to reliably measure dynamic changes in the atomic structure of monatomic crystalline nanomaterials from a time series of atomic resolution annular dark field scanning transmission electron microscopy images. The approach is based on the so-called hidden Markov model and estimates the number of atoms in each atomic column of the nanomaterial in each frame of the time series. We discuss the origin of the improved performance for time series atom-counting as compared to the current state-of-the-art atom-counting procedures, and show that the so-called transition probabilities that describe the probability for an atomic column to lose or gain one or more atoms from frame to frame are particularly important. Using these transition probabilities, we show that the method can also be used to estimate the probability and cross section related to structural changes. Furthermore, we explore the possibilities for applying the method to time series recorded under variable environmental conditions. The method is shown to be promising for a reliable quantitative analysis of dynamic processes such as surface diffusion, adatom dynamics, beam effects, or in situ experiments.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.2
DOI: 10.1016/j.ultramic.2020.113131
|
|
|
“A simple method to clean ligand contamination on TEM grids”. Li C, Tardajos AP, Wang D, Choukroun D, Van Daele K, Breugelmans T, Bals S, Ultramicroscopy 221, 113195 (2021). http://doi.org/10.1016/j.ultramic.2020.113195
Abstract: Colloidal nanoparticles (NPs) including nanowires and nanosheets made by chemical methods involve many organic ligands. When the structure of NPs is investigated via transmission electron microscopy (TEM), the organic ligands act as a source for e-beam induced deposition and this causes substantial build-up of carbon layers in the investigated areas, which is typically referred to as “contamination” in the eld of electron mi- croscopy. This contamination is often more severe for scanning TEM, a technique that is based on a focused electron beam and hence higher electron dose rate. In this paper, we report a simple and effective method to clean drop-cast TEM grids that contain NPs with ligands. Using a combination of activated carbon and ethanol, this method effectively reduces the amount of ligands on TEM grids, and therefore greatly improves the quality of electron microscopy images and subsequent analytical measurements. This ef cient and facile method can be helpful during electron microscopy investigation of different kinds of nanomaterials that suffer from ligand- induced contamination.
Keywords: A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT); Applied Electrochemistry & Catalysis (ELCAT)
Impact Factor: 2.843
Times cited: 10
DOI: 10.1016/j.ultramic.2020.113195
|
|
|
“Modelling ADF STEM images using elliptical Gaussian peaks and its effects on the quantification of structure parameters in the presence of sample tilt”. De wael A, De Backer A, Lobato I, Van Aert S, Ultramicroscopy , 113391 (2021). http://doi.org/10.1016/j.ultramic.2021.113391
Abstract: A small sample tilt away from a main zone axis orientation results in an elongation of the atomic columns in ADF STEM images. An often posed research question is therefore whether the ADF STEM image intensities of tilted nanomaterials should be quantified using a parametric imaging model consisting of elliptical rather than the currently used symmetrical peaks. To this purpose, simulated ADF STEM images corresponding to different amounts of sample tilt are studied using a parametric imaging model that consists of superimposed 2D elliptical Gaussian peaks on the one hand and symmetrical Gaussian peaks on the other hand. We investigate the quantification of structural parameters such as atomic column positions and scattering cross sections using both parametric imaging models. In this manner, we quantitatively study what can be gained from this elliptical model for quantitative ADF STEM, despite the increased parameter space and computational effort. Although a qualitative improvement can be achieved, no significant quantitative improvement in the estimated structure parameters is achieved by the elliptical model as compared to the symmetrical model. The decrease in scattering cross sections with increasing sample tilt is even identical for both types of parametric imaging models. This impedes direct comparison with zone axis image simulations. Nonetheless, we demonstrate how reliable atom-counting can still be achieved in the presence of small sample tilt.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
DOI: 10.1016/j.ultramic.2021.113391
|
|
|
“Reducing electron beam damage through alternative STEM scanning strategies, Part I: Experimental findings”. Velazco A, Béché, A, Jannis D, Verbeeck J, Ultramicroscopy 232, 113398 (2022). http://doi.org/10.1016/j.ultramic.2021.113398
Abstract: The highly energetic electrons in a transmission electron microscope (TEM) can alter or even completely destroy the structure of samples before sufficient information can be obtained. This is especially problematic in the case of zeolites, organic and biological materials. As this effect depends on both the electron beam and the sample and can involve multiple damage pathways, its study remained difficult and is plagued with irreproducibility issues, circumstantial evidence, rumors, and a general lack of solid data. Here we take on the experimental challenge to investigate the role of the STEM scan pattern on the damage behavior of a commercially available zeolite sample with the clear aim to make our observations as reproducible as possible. We make use of a freely programmable scan engine that gives full control over the tempospatial distribution of the electron probe on the sample and we use its flexibility to obtain multiple repeated experiments under identical conditions comparing the difference in beam damage between a conventional raster scan pattern and a newly proposed interleaved scan pattern that provides exactly the same dose and dose rate and visits exactly the same scan points. We observe a significant difference in beam damage for both patterns with up to 11 % reduction in damage (measured from mass loss). These observations demonstrate without doubt that electron dose, dose rate and acceleration voltage are not the only parameters affecting beam damage in (S)TEM experiments and invite the community to rethink beam damage as an unavoidable consequence of applied electron dose.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.2
Times cited: 18
DOI: 10.1016/j.ultramic.2021.113398
|
|
|
“Shape from projections via differentiable forward projector for computed tomography”. Koo J, Dahl AB, Bærentzen JA, Chen Q, Bals S, Dahl VA, Ultramicroscopy 224, 113239 (2021). http://doi.org/10.1016/j.ultramic.2021.113239
Abstract: In computed tomography, the reconstruction is typically obtained on a voxel grid. In this work, however, we propose a mesh-based reconstruction method. For tomographic problems, 3D meshes have mostly been studied to simulate data acquisition, but not for reconstruction, for which a 3D mesh means the inverse process of estimating shapes from projections. In this paper, we propose a differentiable forward model for 3D meshes that bridge the gap between the forward model for 3D surfaces and optimization. We view the forward projection as a rendering process, and make it differentiable by extending recent work in differentiable rendering. We use the proposed forward model to reconstruct 3D shapes directly from projections. Experimental results for single-object problems show that the proposed method outperforms traditional voxel-based methods on noisy simulated data. We also apply the proposed method on electron tomography images of nanoparticles to demonstrate the applicability of the method on real data.
Keywords: A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 3
DOI: 10.1016/j.ultramic.2021.113239
|
|
|
“Event driven 4D STEM acquisition with a Timepix3 detector: Microsecond dwell time and faster scans for high precision and low dose applications”. Jannis D, Hofer C, Gao C, Xie X, Béché, A, Pennycook Tj, Verbeeck J, Ultramicroscopy 233, 113423 (2022). http://doi.org/10.1016/j.ultramic.2021.113423
Abstract: Four dimensional scanning transmission electron microscopy (4D STEM) records the scattering of electrons in a material in great detail. The benefits offered by 4D STEM are substantial, with the wealth of data it provides facilitating for instance high precision, high electron dose efficiency phase imaging via centre of mass or ptychography based analysis. However the requirement for a 2D image of the scattering to be recorded at each probe position has long placed a severe bottleneck on the speed at which 4D STEM can be performed. Recent advances in camera technology have greatly reduced this bottleneck, with the detection efficiency of direct electron detectors being especially well suited to the technique. However even the fastest frame driven pixelated detectors still significantly limit the scan speed which can be used in 4D STEM, making the resulting data susceptible to drift and hampering its use for low dose beam sensitive applications. Here we report the development of the use of an event driven Timepix3 direct electron camera that allows us to overcome this bottleneck and achieve 4D STEM dwell times down to 100 ns; orders of magnitude faster than what has been possible with frame based readout. We characterize the detector for different acceleration voltages and show that the method is especially well suited for low dose imaging and promises rich datasets without compromising dwell time when compared to conventional STEM imaging.
Keywords: A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT)
Impact Factor: 2.2
Times cited: 31
DOI: 10.1016/j.ultramic.2021.113423
|
|
|
“ab initio description of bonding for transmission electron microscopy”. Madsen J, Pennycook TJ, Susi T, Ultramicroscopy 231 (2021). http://doi.org/10.1016/J.ULTRAMIC.2021.113253
Abstract: The simulation of transmission electron microscopy (TEM) images or diffraction patterns is often required to interpret their contrast and extract specimen features. This is especially true for high-resolution phase-contrast imaging of materials, but electron scattering simulations based on atomistic models are widely used in materials science and structural biology. Since electron scattering is dominated by the nuclear cores, the scattering potential is typically described by the widely applied independent atom model. This approximation is fast and fairly accurate, especially for scanning TEM (STEM) annular dark-field contrast, but it completely neglects valence bonding and its effect on the transmitting electrons. However, an emerging trend in electron microscopy is to use new instrumentation and methods to extract the maximum amount of information from each electron. This is evident in the increasing popularity of techniques such as 4D-STEM combined with ptychography in materials science, and cryogenic microcrystal electron diffraction in structural biology, where subtle differences in the scattering potential may be both measurable and contain additional insights. Thus, there is increasing interest in electron scattering simulations based on electrostatic potentials obtained from first principles, mainly via density functional theory, which was previously mainly required for holography. In this Review, we discuss the motivation and basis for these developments, survey the pioneering work that has been published thus far, and give our outlook for the future. We argue that a physically better justified ab initio description of the scattering potential is both useful and viable for an increasing number of systems, and we expect such simulations to steadily gain in popularity and importance.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
DOI: 10.1016/J.ULTRAMIC.2021.113253
|
|
|
“Reliable phase quantification in focused probe electron ptychography of thin materials”. Hofer C, Pennycook TJ, Ultramicroscopy 254, 113829 (2023). http://doi.org/10.1016/j.ultramic.2023.113829
Abstract: Electron ptychography provides highly sensitive, dose efficient phase images which can be corrected for aberrations after the data has been acquired. This is crucial when very precise quantification is required, such as with sensitivity to charge transfer due to bonding. Drift can now be essentially eliminated as a major impediment to focused probe ptychography, which benefits from the availability of easily interpretable simultaneous Z-contrast imaging. However challenges have remained when quantifying the ptychographic phases of atomic sites. The phase response of a single atom has a negative halo which can cause atoms to reduce in phase when brought closer together. When unaccounted for, as in integrating methods of quantification, this effect can completely obscure the effects of charge transfer. Here we provide a new method of quantification that overcomes this challenge, at least for 2D materials, and is robust to experimental parameters such as noise, sample tilt.
Keywords: A1 Journal Article; Electron Microscopy for Materials Science (EMAT) ;
Impact Factor: 2.2
DOI: 10.1016/j.ultramic.2023.113829
|
|
|
“Nanowire facilitated transfer of sensitive TEM samples in a FIB”. Gorji S, Kashiwar A, Mantha LS, Kruk R, Witte R, Marek P, Hahn H, Kübel C, Scherer T, Ultramicroscopy 219, 113075 (2020). http://doi.org/10.1016/J.ULTRAMIC.2020.113075
Abstract: We introduce a facile approach to transfer thin films and other mechanically sensitive TEM samples inside a FIB with minimal introduction of stress and bending. The method is making use of a pre-synthetized flexible freestanding Ag nanowire attached to the tip of a typical tungsten micromanipulator inside the FIB. The main advantages of this approach are the significantly reduced stress-induced bending during transfer and attachment of the TEM sample, the very short time required to attach and cut the nanowire, the operation at very low dose and ion current, and only using the e-beam for Pt deposition during the transfer of sensitive TEM samples. This results in a reduced sample preparation time and reduced exposure to the ion beam or e-beam for Pt deposition during the sample preparation and thus also reduced contamination and beam damage. The method was applied to a number of thin films and different TEM samples in order to illustrate the advantageous benefits of the concept. In particular, the technique has been successfully tested for the transfer of a thin film onto a MEMS heating chip for in situ TEM experiments.
Keywords: A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT)
Impact Factor: 2.2
DOI: 10.1016/J.ULTRAMIC.2020.113075
|
|
|
“Dynamical diffraction of high-energy electrons investigated by focal series momentum-resolved scanning transmission electron microscopy at atomic resolution”. Robert Hl, Lobato I, Lyu Fj, Chen Q, Van Aert S, Van Dyck D, Müller-Caspary K, Ultramicroscopy 233, 113425 (2022). http://doi.org/10.1016/j.ultramic.2021.113425
Abstract: We report a study of scattering dynamics in crystals employing momentum-resolved scanning transmission
electron microscopy under varying illumination conditions. As we perform successive changes of the probe
focus, multiple real-space signals are obtained in dependence of the shape of the incident electron wave.
With support from extensive simulations, each signal is shown to be characterised by an optimum focus for
which the contrast is maximum and which differs among different signals. For instance, a systematic focus
mismatch is found between images formed by high-angle scattering, being sensitive to thickness and chemical
composition, and the first moment in diffraction space, being sensitive to electric fields. It follows that a single
recording at one specific probe focus is usually insufficient to characterise materials comprehensively. Most
importantly, we demonstrate in experiment and simulation that the second moment (
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.2
DOI: 10.1016/j.ultramic.2021.113425
|
|
|
“Reducing electron beam damage through alternative STEM scanning strategies, Part II: Attempt towards an empirical model describing the damage process”. Jannis D, Velazco A, Béché, A, Verbeeck J, Ultramicroscopy , 113568 (2022). http://doi.org/10.1016/j.ultramic.2022.113568
Abstract: In this second part of a series we attempt to construct an empirical model that can mimick all experimental observations made regarding the role of an alternative interleaved scan pattern in STEM imaging on the beam damage in a specific zeolite sample. We make use of a 2D diffusion model that describes the dissipation of the deposited beam energy in the sequence of probe positions that are visited during the scan pattern. The diffusion process allows for the concept of trying to ‘outrun’ the beam damage by carefully tuning the dwell time and distance between consecutively visited probe positions. We add a non linear function to include a threshold effect and evaluate the accumulated damage in each part of the image as a function of scan pattern details. Together, these ingredients are able to describe qualitatively all aspects of the experimental data and provide us with a model that could guide a further optimisation towards even lower beam damage without lowering the applied electron dose. We deliberately remain vague on what is diffusing here which avoids introducing too many sample specific details. This provides hope that the model can be applied also in sample classes that were not yet studied in such great detail by adjusting higher level parameters: a sample dependent diffusion constant and damage threshold.
Keywords: A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT)
Impact Factor: 2.2
Times cited: 4
DOI: 10.1016/j.ultramic.2022.113568
|
|
|
“Phase offset method of ptychographic contrast reversal correction”. Hofer C, Gao C, Chennit T, Yuan B, Pennycook TJ, Ultramicroscopy , 113922 (2024). http://doi.org/10.1016/j.ultramic.2024.113922
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.2
DOI: 10.1016/j.ultramic.2024.113922
|
|
|
“Optimal experiment design for element specific atom counting using multiple annular dark field scanning transmission electron microscopy detectors”. Sentürk DG, De Backer A, Friedrich T, Van Aert S, Ultramicroscopy 242, 113626 (2022). http://doi.org/10.1016/j.ultramic.2022.113626
Abstract: This paper investigates the possible benefits for counting atoms of different chemical nature when analysing multiple 2D scanning transmission electron microscopy (STEM) images resulting from independent annular dark field (ADF) detector regimes. To reach this goal, the principles of statistical detection theory are used to quantify the probability of error when determining the number of atoms in atomic columns consisting of multiple types of elements. In order to apply this theory, atom-counting is formulated as a statistical hypothesis test, where each hypothesis corresponds to a specific number of atoms of each atom type in an atomic column. The probability of error, which is limited by the unavoidable presence of electron counting noise, can then be computed from scattering-cross sections extracted from multiple ADF STEM images. Minimisation of the probability of error as a function of the inner and outer angles of a specified number of independent ADF collection regimes results in optimal experimental designs. Based on simulations of spherical Au@Ag and Au@Pt core–shell nanoparticles, we investigate how the combination of two non-overlapping detector regimes helps to improve the probability of error when unscrambling two types of atoms. In particular, the combination of a narrow low angle ADF detector with a detector formed by the remaining annular collection regime is found to be optimal. The benefit is more significant if the atomic number Z difference becomes larger. In
addition, we show the benefit of subdividing the detector regime into three collection areas for heterogeneous nanostructures based on a structure consisting of three types of elements, e.g., a mixture of Au, Ag and Al atoms. Finally, these results are compared with the probability of error resulting when one would ultimately use a pixelated 4D STEM detector and how this could help to further reduce the incident electron dose.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.2
DOI: 10.1016/j.ultramic.2022.113626
|
|
|
“Real-time simulations of ADF STEM probe position-integrated scattering cross-sections for single element fcc crystals in zone axis orientation using a densely connected neural network”. Lobato I, De Backer A, Van Aert S, Ultramicroscopy 251, 113769 (2023). http://doi.org/10.1016/j.ultramic.2023.113769
Abstract: Quantification of annular dark field (ADF) scanning transmission electron microscopy (STEM) images in terms
of composition or thickness often relies on probe-position integrated scattering cross sections (PPISCS). In
order to compare experimental PPISCS with theoretically predicted ones, expensive simulations are needed for
a given specimen, zone axis orientation, and a variety of microscope settings. The computation time of such
simulations can be in the order of hours using a single GPU card. ADF STEM simulations can be efficiently
parallelized using multiple GPUs, as the calculation of each pixel is independent of other pixels. However, most
research groups do not have the necessary hardware, and, in the best-case scenario, the simulation time will
only be reduced proportionally to the number of GPUs used. In this manuscript, we use a learning approach and
present a densely connected neural network that is able to perform real-time ADF STEM PPISCS predictions as
a function of atomic column thickness for most common face-centered cubic (fcc) crystals (i.e., Al, Cu, Pd, Ag,
Pt, Au and Pb) along [100] and [111] zone axis orientations, root-mean-square displacements, and microscope
parameters. The proposed architecture is parameter efficient and yields accurate predictions for the PPISCS
values for a wide range of input parameters that are commonly used for aberration-corrected transmission
electron microscopes.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.2
DOI: 10.1016/j.ultramic.2023.113769
|
|
|
“Characterization of a Timepix detector for use in SEM acceleration voltage range”. Denisov N, Jannis D, Orekhov A, Müller-Caspary K, Verbeeck J, Ultramicroscopy 253, 113777 (2023). http://doi.org/10.1016/j.ultramic.2023.113777
Abstract: Hybrid pixel direct electron detectors are gaining popularity in electron microscopy due to their excellent properties. Some commercial cameras based on this technology are relatively affordable which makes them attractive tools for experimentation especially in combination with an SEM setup. To support this, a detector characterization (Modulation Transfer Function, Detective Quantum Efficiency) of an Advacam Minipix and Advacam Advapix detector in the 15–30 keV range was made. In the current work we present images of Point Spread Function, plots of MTF/DQE curves and values of DQE(0) for these detectors. At low beam currents, the silicon detector layer behaviour should be dominant, which could make these findings transferable to any other available detector based on either Medipix2, Timepix or Timepix3 provided the same detector layer is used.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.2
DOI: 10.1016/j.ultramic.2023.113777
|
|
|
“Atom counting from a combination of two ADF STEM images”. Şentürk DG, Yu CP, De Backer A, Van Aert S, Ultramicroscopy 255, 113859 (2024). http://doi.org/10.1016/j.ultramic.2023.113859
Abstract: To understand the structure–property relationship of nanostructures, reliably quantifying parameters, such as the number of atoms along the projection direction, is important. Advanced statistical methodologies have made it possible to count the number of atoms for monotype crystalline nanoparticles from a single ADF STEM image. Recent developments enable one to simultaneously acquire multiple ADF STEM images. Here, we present an extended statistics-based method for atom counting from a combination of multiple statistically independent ADF STEM images reconstructed from non-overlapping annular detector collection regions which improves the accuracy and allows one to retrieve precise atom-counts, especially for images acquired with low electron doses and multiple element structures.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.2
DOI: 10.1016/j.ultramic.2023.113859
|
|
|
“Convexity constraints on linear background models for electron energy-loss spectra”. Van den Broek W, Jannis D, Verbeeck J, Ultramicroscopy 254, 113830 (2023). http://doi.org/10.1016/j.ultramic.2023.113830
Abstract: In this paper convexity constraints are derived for a background model of electron energy loss spectra (EELS) that is linear in the fitting parameters. The model outperforms a power-law both on experimental and simulated backgrounds, especially for wide energy ranges, and thus improves elemental quantification results. Owing to the model’s linearity, the constraints can be imposed through fitting by quadratic programming. This has important advantages over conventional nonlinear power-law fitting such as high speed and a guaranteed unique solution without need for initial parameters. As such, the need for user input is significantly reduced, which is essential for unsupervised treatment of large datasets. This is demonstrated on a demanding spectrum image of a semiconductor device sample with a high number of elements over a wide energy range.
Keywords: A1 Journal Article; Electron Microscopy for Materials Science (EMAT) ;
Impact Factor: 2.2
DOI: 10.1016/j.ultramic.2023.113830
|
|
|
“Element specific atom counting for heterogeneous nanostructures: Combining multiple ADF STEM images for simultaneous thickness and composition determination”. Şentürk DG, De Backer A, Van Aert S, Ultramicroscopy 259, 113941 (2024). http://doi.org/10.1016/j.ultramic.2024.113941
Abstract: In this paper, a methodology is presented to count the number of atoms in heterogeneous nanoparticles based on the combination of multiple annular dark field scanning transmission electron microscopy (ADF STEM) images. The different non-overlapping annular detector collection regions are selected based on the principles of optimal statistical experiment design for the atom-counting problem. To count the number of atoms, the total intensities of scattered electrons for each atomic column, the so-called scattering cross-sections, are simultaneously compared with simulated library values for the different detector regions by minimising the squared differences. The performance of the method is evaluated for simulated Ni@Pt and Au@Ag core-shell nanoparticles. Our approach turns out to be a dose efficient alternative for the investigation of beam-sensitive heterogeneous materials as compared to the combination of ADF STEM and energy dispersive X-ray spectroscopy.
Keywords: A1 Journal Article; Electron Microscopy for Materials Science (EMAT) ;
Impact Factor: 2.2
DOI: 10.1016/j.ultramic.2024.113941
|
|
|
“RSV frequency in children below 2 years hospitalized for lower respiratory tract infections”. Hacimustafaoglu M, Celebi S, Bozdemir SE, Ozgur T, Ozcan I, Guray A, Çakir D, Turkish Journal Of Pediatrics 55, 130 (2013)
Abstract: Respiratory syncytial virus (RSV) is the most frequent agent of acute lower respiratory diseases and creates a significant burden of disease in children under 5 years all over the world. RSV causes severe lower respiratory tract infections (LRTI) that require hospitalization, especially in children <= 2 years. The aim of this study was to determine the incidence of RSV in children <= 2 years of age hospitalized for LRTI. Children <= 2 years of age hospitalized for one year for LRTI in the three largest hospitals of Bursa City Center, Turkey were evaluated. These three hospitals comprise 67.5% of all child beds in central Bursa, so this study allows us to evaluate the total disease burden and hospitalization incidence in central Bursa. Nasal swabs of the children were evaluated with RSV RespiStrip (Coris Bioconcept Organization). A total of 671 children were hospitalized for LRTI, and 254 (37.9%) had at least one hospitalization that was positive for RSV. Of all patients with LRTI, 54.8% (368/671) were hospitalized for acute bronchiolitis, while 45.2% (303/671) were hospitalized for pneumonia. Of patients with acute bronchiolitis or pneumonia, 41% (151/368) and 34% (103/303) were RSV+, respectively. Of RSV+ hospitalized children, 59.5% (151/254) were diagnosed as acute bronchiolitis and 40.5% (103/254) as pneumonia. The annual incidences of hospitalization due to LRTI, acute bronchiolitis and pneumonia were 20.5/1000, 11.2/1000 and 9.3/1000, respectively, in children <= 2 years of age. The annual incidences of hospitalization due to RSV+ LRTI, acute bronchiolitis and pneumonia were found as 7.8/1000, 4.6/1000 and 3.2/1000, respectively, in children <= 2 years of age. More than one-third of all children hospitalized with LRTI (38.3%, n=257) were in the 0-3 months age group. Compared to other age groups, RSV positivity was highest in that age group for acute bronchiolitis (57%), pneumonia (39.5%) and also total children with LRTI (47.9%). RSV is a very important cause of lower respiratory infections in children <= 2 years of age and occurred most frequently in those 0-3 months of age in our study. Since there is no other study assessing the annual hospitalization incidence of RSV+ LRTIs in one city in Turkey, our study has unique importance for providing valuable statistical data about RSV+ LRTIs.
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 0.32
|
|
|
“Nanodiamond-based nanolubricants : investigation of friction surfaces”. Shenderova O, Vargas A, Turner S, Ivanov DM, Ivanov MG, Tribology transactions 57, 1051 (2014). http://doi.org/10.1080/10402004.2014.933933
Abstract: Synergistic compositions of detonation nanodiamond (DND) particles with polytetrafluoroethylene and molybdenum dialkyldithiophosphate were used in ring-on-ring, four-ball, and block-on-ring tests as an additive to polyalphaolefins and engine oils. Modest to significant reductions in the friction coefficients, wear, or both were observed. In the wear scars produced in the block-on-ring tests, the friction surfaces were characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), and profilometry. Significant polishing effects of the friction surfaces in lubricants containing DND were revealed in SEM observations and roughness measurements. The roughness of the scar surfaces produced in the presence of DND additives was about 35% lower than the roughness of the scars observed in pure oil experiments.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 1.685
Times cited: 23
DOI: 10.1080/10402004.2014.933933
|
|
|
“Mitigation strategies for radiation damage in the analysis of ancient materials”. Bertrand L, Schoeeder S, Anglos D, Breese MBH, Janssens K, Moini M, Simon A, Trends in analytical chemistry 66, 128 (2015). http://doi.org/10.1016/J.TRAC.2014.10.005
Abstract: The study of materials in cultural heritage artifacts and micro-samples benefits from diagnostic techniques based on intense radiation sources, such as synchrotrons, ion-beam accelerators and lasers. While most of the corresponding techniques are classified as non-destructive, investigation with photons or charged particles entails a number of fundamental processes that may induce changes in materials. These changes depend on irradiation parameters, properties of materials and environmental factors. In some cases, radiation-induced damage may be detected by visual inspection. When it is not, irradiation may still lead to atomic and molecular changes resulting in immediate or delayed alteration and bias of future analyses. Here we review the effects of radiation reported on a variety of cultural heritage materials and describe the usual practice for assessing short-term and long-term effects. This review aims to raise awareness and encourage subsequent research activities to limit radiation side effects.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 8.442
Times cited: 35
DOI: 10.1016/J.TRAC.2014.10.005
|
|
|
“Recent trends in quantitative aspects of microscopic X-ray fluorescence analysis”. Janssens K, de Nolf W, van der Snickt G, Vincze L, Vekemans B, Terzano R, Brenker FE, Trends in analytical chemistry 29, 464 (2010). http://doi.org/10.1016/J.TRAC.2010.03.003
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 8.442
Times cited: 48
DOI: 10.1016/J.TRAC.2010.03.003
|
|
|
“Analytical techniques for the detection of amphetamine-type substances in different matrices : a comprehensive review”. Drăgan A-M, Parrilla M, Feier B, Oprean R, Cristea C, De Wael K, Trac-Trends In Analytical Chemistry 145, 116447 (2021). http://doi.org/10.1016/J.TRAC.2021.116447
Abstract: This current review focuses on contributions to amphetamine-type substances (ATS) analysis. This type of synthetic illicit drugs has been increasingly present worldwide reaching 5% of the market on illicit drugs in 2019. The increment of their production in many clandestine laboratories and easy distribution among society are two of the main concerns towards the battle against synthetic drugs. Therefore, the first part of this review details the classification and mechanism of action of ATS in the human body. Second, the pharmacological and toxicological effects of ATS on human health are described to motivate the need of early detection of ATS. Subsequently, the most used laboratory-based and portable methods are presented and critically discussed along the review. Finally, a careful discussion on the advantages and disadvantages of portable techniques employed on the field are addressed as potential tools for on-site ATS detection by law enforcement officers.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 8.442
DOI: 10.1016/J.TRAC.2021.116447
|
|
|
“Mapping the gaps in chemical analysis for the characterisation of aptamer-target interactions”. Daems E, Moro G, Campos R, De Wael K, Trac-Trends In Analytical Chemistry 142, 116311 (2021). http://doi.org/10.1016/J.TRAC.2021.116311
Abstract: Aptamers are promising biorecognition elements with a wide applicability from therapeutics to bio-sensing. However, to successfully use these biomolecules, a complete characterisation of their bindingperformance in the presence of the target is crucial. Several multi-analytical approaches have been re-ported including techniques to describe kinetic and thermodynamic aspects of the aptamer-targetinteraction, and techniques which allow an in-depth understanding of the aptamer-target structures.Recent literature shows the need of a critical data interpretation, a combination of characterisationtechniques and suggests the key role of the characterisation protocol design. Indeed, thefinal applicationof the aptamer should be considered before choosing the characterisation method. All the limitations andcapabilities of the analytical tools in use for aptamer characterisation should be taken into account. Here,we present a critical overview of the current methods and multi-analytical approaches to study aptamer-target binding, aiming to provide researchers with guidelines for the design of characterisation protocols.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 8.442
DOI: 10.1016/J.TRAC.2021.116311
|
|
|
“Non-invasive and non-destructive examination of artistic pigments, paints, and paintings by means of X-Ray methods”. Janssens K, van der Snickt G, Vanmeert F, Legrand S, Nuyts G, Alfeld M, Monico L, Anaf W, de Nolf W, Vermeulen M, Verbeeck J, De Wael K, Topics in Current Chemistry 374, 81 (2016). http://doi.org/10.1007/S41061-016-0079-2
Abstract: Recent studies are concisely reviewed, in which X-ray beams of (sub)micrometre to millimetre dimensions have been used for non-destructive analysis and characterization of pigments, minute paint samples, and/or entire paintings from the seventeenth to the early twentieth century painters. The overview presented encompasses the use of laboratory and synchrotron radiation-based instrumentation and deals with the use of several variants of X-ray fluorescence (XRF) as a method of elemental analysis and imaging, as well as with the combined use of X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS). Microscopic XRF is a variant of the method that is well suited to visualize the elemental distribution of key elements, mostly metals, present in paint multi-layers, on the length scale from 1 to 100 μm inside micro-samples taken from paintings. In the context of the characterization of artists pigments subjected to natural degradation, the use of methods limited to elemental analysis or imaging usually is not sufficient to elucidate the chemical transformations that have taken place. However, at synchrotron facilities, combinations of μ-XRF with related methods such as μ-XAS and μ-XRD have proven themselves to be very suitable for such studies. Their use is often combined with microscopic Fourier transform infra-red spectroscopy and/or Raman microscopy since these methods deliver complementary information of high molecular specificity at more or less the same length scale as the X-ray microprobe techniques. Since microscopic investigation of a relatively limited number of minute paint samples, taken from a given work of art, may not yield representative information about the entire artefact, several methods for macroscopic, non-invasive imaging have recently been developed. Those based on XRF scanning and full-field hyperspectral imaging appear very promising; some recent published results are discussed.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.033
Times cited: 50
DOI: 10.1007/S41061-016-0079-2
|
|