Records |
Author |
Gjorgievska, E.; Van Tendeloo, G.; Nicholson, J.W.; Coleman, N.J.; Slipper, I.J.; Booth, S. |
Title |
The incorporation of nanoparticles into conventional glass-ionomer dental restorative cements |
Type |
A1 Journal article |
Year |
2015 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
Volume |
21 |
Issue |
21 |
Pages |
392-406 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
Conventional glass-ionomer cements (GICs) are popular restorative materials, but their use is limited by their relatively low mechanical strength. This paper reports an attempt to improve these materials by incorporation of 10 wt% of three different types of nanoparticles, aluminum oxide, zirconium oxide, and titanium dioxide, into two commercial GICs (ChemFil((R)) Rock and EQUIA (TM) Fil). The results indicate that the nanoparticles readily dispersed into the cement matrix by hand mixing and reduced the porosity of set cements by filling the empty spaces between the glass particles. Both cements showed no significant difference in compressive strength with added alumina, and ChemFil((R)) Rock also showed no significant difference with zirconia. By contrast, ChemFil((R)) Rock showed significantly higher compressive strength with added titania, and EQUIA (TM) Fil showed significantly higher compressive strength with both zirconia and titania. Fewer air voids were observed in all nanoparticle-containing cements and this, in turn, reduced the development of cracks within the matrix of the cements. These changes in microstructure provide a likely reason for the observed increases in compressive strength, and overall the addition of nanoparticles appears to be a promising strategy for improving the physical properties of GICs. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Cambridge, Mass. |
Editor |
|
Language |
|
Wos |
000353514700014 |
Publication Date |
2015-02-18 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
1.891 |
Times cited |
15 |
Open Access |
|
Notes |
|
Approved |
Most recent IF: 1.891; 2015 IF: 1.877 |
Call Number |
UA @ lucian @ c:irua:132523 |
Serial |
4194 |
Permanent link to this record |
|
|
|
Author |
Heidari, H.; Rivero, G.; Idrissi, H.; Ramachandran, D.; Cakir, S.; Egoavil, R.; Kurttepeli, M.; Crabbé, A.C.; Hauffman, T.; Terryn, H.; Du Prez, F.; Schryvers, D. |
Title |
Melamine–Formaldehyde Microcapsules: Micro- and Nanostructural Characterization with Electron Microscopy |
Type |
A1 Journal article |
Year |
2016 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
Volume |
22 |
Issue |
22 |
Pages |
1222-1232 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
A systematic study has been carried out to compare the surface morphology, shell thickness, mechanical properties, and binding behavior of melamine–formaldehyde microcapsules of 5–30 μm diameter size with various amounts of core content by using scanning and transmission electron microscopy including electron tomography, in situ nanomechanical tensile testing, and electron energy-loss spectroscopy. It is found that porosities are present on the outside surface of the capsule shell, but not on the inner surface of the shell. Nanomechanical tensile tests on the capsule shells reveal that Young’s modulus of the shell material is higher than that of bulk melamine–formaldehyde and that the shells exhibit a larger fracture strain compared with the bulk. Core-loss elemental analysis of microcapsules embedded in epoxy indicates that during the curing process, the microcapsule-matrix interface remains uniform and the epoxy matrix penetrates into the surface micro-porosities of the capsule shells. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000393853100011 |
Publication Date |
2016-12-21 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
1.891 |
Times cited |
2 |
Open Access |
|
Notes |
This work was supported by SIM vzw, Technologiepark 935, BE-9052 Zwijnaarde, Belgium, within the InterPoCo project of the H-INT-S horizontal program. The authors are also thankful to Stijn Van den Broeck and Dr. Frederic Leroux for help in sample preparation and to S. Bals and J. Verbeeck for valuable discussions. H.I. acknowledges the IAP program of the Belgian State Federal Office for Scientific, Technical and Cultural Affairs, under Contract No. P7/21. |
Approved |
Most recent IF: 1.891 |
Call Number |
EMAT @ emat @ c:irua:138980 |
Serial |
4333 |
Permanent link to this record |
|
|
|
Author |
Jones, L.; Martinez, G.T.; Béché, A.; Van Aert, S.; Nellist, P.D. |
Title |
Getting the best from an imperfect detector : an alternative normalisation procedure for quantitative HAADF STEM |
Type |
A1 Journal article |
Year |
2014 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
Volume |
20 |
Issue |
S3 |
Pages |
126-127 |
Keywords |
A1 Journal article; Engineering Management (ENM); Electron microscopy for materials research (EMAT) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Cambridge, Mass. |
Editor |
|
Language |
|
Wos |
|
Publication Date |
2014-08-27 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
UA library record |
Impact Factor |
1.891 |
Times cited |
|
Open Access |
|
Notes |
|
Approved |
Most recent IF: 1.891; 2014 IF: 1.877 |
Call Number |
UA @ lucian @ c:irua:136445 |
Serial |
4500 |
Permanent link to this record |
|
|
|
Author |
Nord, M.; Verbeeck, J. |
Title |
Open Source Development Tools for Robust and Reproducible Electron Microscopy Data Analysis |
Type |
P3 |
Year |
2019 |
Publication |
Microscopy And Microanalysis |
Abbreviated Journal |
Microsc Microanal |
Volume |
25 |
Issue |
S2 |
Pages |
138-139 |
Keywords |
P3; Electron Microscopy for Materials Science (EMAT) ; |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
|
Publication Date |
2019-08-05 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
|
Impact Factor |
1.891 |
Times cited |
|
Open Access |
|
Notes |
|
Approved |
Most recent IF: 1.891 |
Call Number |
EMAT @ emat @ |
Serial |
5378 |
Permanent link to this record |
|
|
|
Author |
Pennycook, T.J.; Martinez, G.T.; O'Leary, C.M.; Yang, H.; Nellist, P.D. |
Title |
Efficient Phase Contrast Imaging via Electron Ptychography, a Tutorial |
Type |
A1 Journal article |
Year |
2019 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
Volume |
25 |
Issue |
S2 |
Pages |
2684-2685 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
|
Publication Date |
2019-08-06 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
UA library record |
Impact Factor |
|
Times cited |
|
Open Access |
|
Notes |
|
Approved |
no |
Call Number |
EMAT @ emat @c:irua:172444 |
Serial |
6424 |
Permanent link to this record |
|
|
|
Author |
Nord, M.; Webster, R.W.H.; Paton, K.A.; McVitie, S.; McGrouther, D.; MacLaren, I.; Paterson, G.W. |
Title |
Fast pixelated detectors in scanning transmission electron microscopy. Part I: data acquisition, live processing, and storage |
Type |
A1 Journal article |
Year |
2020 |
Publication |
Microscopy And Microanalysis |
Abbreviated Journal |
Microsc Microanal |
Volume |
26 |
Issue |
4 |
Pages |
Pii S1431927620001713-666 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
The use of fast pixelated detectors and direct electron detection technology is revolutionizing many aspects of scanning transmission electron microscopy (STEM). The widespread adoption of these new technologies is impeded by the technical challenges associated with them. These include issues related to hardware control, and the acquisition, real-time processing and visualization, and storage of data from such detectors. We discuss these problems and present software solutions for them, with a view to making the benefits of new detectors in the context of STEM more accessible. Throughout, we provide examples of the application of the technologies presented, using data from a Medipix3 direct electron detector. Most of our software are available under an open source licence, permitting transparency of the implemented algorithms, and allowing the community to freely use and further improve upon them. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000555537900004 |
Publication Date |
2020-07-06 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.8 |
Times cited |
4 |
Open Access |
OpenAccess |
Notes |
; The performance of this work was mainly supported by the Engineering and Physical Sciences Research Council (EPSRC) of the UK via the project “Fast Pixel Detectors: a paradigm shift in STEM imaging” (grant no. EP/M009963/1). G.W.P. received additional support from the EPSRC under grant no. EP/M024423/1. M.N. received additional support for this work from the European Union's Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie grant agreement no. 838001. The studentship of R.W.H.W. was supported by the EPSRC Doctoral Training Partnership grant no. EP/N509668/1. S.McV. was supported by EPSRC grant no. EP/M024423/1. I.M. was supported by EPSRC grant no. EP/M009963/1. The studentship of K.A.P. was funded entirely by the UK Science and Technology Facilities Council (STFC) Industrial CASE studentship “Next2 TEM Detection” (no. ST/P002471/1) with Quantum Detectors Ltd. as the industrial partner. D.McG. was also supported by EPSRC grant no. EP/M009963/1. As an inventor of intellectual property related to the MERLIN detector hardware, he is a beneficiary of the license agreement between the University of Glasgow and Quantum Detectors Ltd. The development of the integration of TopSpin with the Merlin readout of the Medipix3 camera has been performed with the aid of financial assistance from the EPSRC under grant no. EP/R511705/1 and through direct collaboration between NanoMEGAS and Quantum Detectors Ltd. ; |
Approved |
Most recent IF: 2.8; 2020 IF: 1.891 |
Call Number |
UA @ admin @ c:irua:171185 |
Serial |
6518 |
Permanent link to this record |
|
|
|
Author |
Paterson, G.W.; Webster, R.W.H.; Ross, A.; Paton, K.A.; Macgregor, T.A.; McGrouther, D.; MacLaren, I.; Nord, M. |
Title |
Fast pixelated detectors in scanning transmission electron microscopy. part II : post-acquisition data processing, visualization, and structural characterization |
Type |
A1 Journal article |
Year |
2020 |
Publication |
Microscopy And Microanalysis |
Abbreviated Journal |
Microsc Microanal |
Volume |
26 |
Issue |
5 |
Pages |
944-963 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
Fast pixelated detectors incorporating direct electron detection (DED) technology are increasingly being regarded as universal detectors for scanning transmission electron microscopy (STEM), capable of imaging under multiple modes of operation. However, several issues remain around the post-acquisition processing and visualization of the often very large multidimensional STEM datasets produced by them. We discuss these issues and present open source software libraries to enable efficient processing and visualization of such datasets. Throughout, we provide examples of the analysis methodologies presented, utilizing data from a 256 x 256 pixel Medipix3 hybrid DED detector, with a particular focus on the STEM characterization of the structural properties of materials. These include the techniques of virtual detector imaging; higher-order Laue zone analysis; nanobeam electron diffraction; and scanning precession electron diffraction. In the latter, we demonstrate a nanoscale lattice parameter mapping with a fractional precision <= 6 x 10(-4) (0.06%). |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000576859800011 |
Publication Date |
2020-09-04 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.8 |
Times cited |
3 |
Open Access |
OpenAccess |
Notes |
; G.W.P. and M.N. were the principal authors of the fpd and pixStem libraries reported herein (details of all contributions are documented in the repositories) and have made all of these available under open source licence GPLv3 for the benefit of the community. R.W.H.W., A.R., and K.A.P. have also made contributions to the source codes in these libraries. G.W.P and M.N. have led the data acquisition and analysis, and the drafting of this manuscript. The performance of this work was mainly supported by Engineering and Physical Sciences Research Council (EPSRC) of the UK via the project “Fast Pixel Detectors: a paradigm shift in STEM imaging” (Grant No. EP/M009963/1). G.W.P. received additional support from the EPSRC under Grant No. EP/M024423/1. M.N. received additional support for this work from the European Union's Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie grant agreement No. 838001. R.W.H.W., A.R., K.A.P., T.A.M., D.McG., and I.M. have all contributed either through acquisition and analysis of data or through participation in the revision of the manuscript. The studentships of R.W.H.W. and T.A.M. were supported by the EPSRC Doctoral Training Partnership Grant No. EP/N509668/1. I.M. and D.McG. were supported by EPSRC Grant No. EP/M009963/1. The studentship of K.A.P. was funded entirely by the UK Science and Technology Facilities Council (STFC) Industrial CASE studentship “Next2 TEM Detection” (No. ST/ P002471/1) with Quantum Detectors Ltd. as the industrial partner. As an inventor of intellectual property related to the MERLIN detector hardware, D.McG. is a beneficiary of the license agreement between the University of Glasgow and Quantum Detectors Ltd. We thank Diamond Quantum Detectors Ltd. for Medipix3 detector support; Dr. Bruno Humbel from Okinawa Institute of Science and Technology; and Dr. Caroline Kizilyaprak from the University of Lausanne for providing the liver sample; Dr. Ingrid Hallsteinsen and Prof. Thomas Tybell from the Norwegian University of Science and Technology (NTNU) for providing the La0.7Sr0.3MnO3/LaFeO3/SrTiO3 sample shown in Figure 4; and NanoMEGAS for the loan of the DigiSTAR precession system and TopSpin acquisition software. The development of the integration of TopSpin with the Merlin readout of the Medipix3 camera has been performed with the aid of financial assistance from the EPSRC under Grant No. EP/R511705/1 and through direct collaboration between NanoMEGAS and Quantum Detectors Ltd. ; |
Approved |
Most recent IF: 2.8; 2020 IF: 1.891 |
Call Number |
UA @ admin @ c:irua:172695 |
Serial |
6519 |
Permanent link to this record |
|
|
|
Author |
MacArthur, K.E.; Yankovich, A.B.; Béché, A.; Luysberg, M.; Brown, H.G.; Findlay, S.D.; Heggen, M.; Allen, L.J. |
Title |
Optimizing Experimental Conditions for Accurate Quantitative Energy-Dispersive X-ray Analysis of Interfaces at the Atomic Scale |
Type |
A1 Journal article |
Year |
2021 |
Publication |
Microscopy And Microanalysis |
Abbreviated Journal |
Microsc Microanal |
Volume |
|
Issue |
|
Pages |
1-15 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
The invention of silicon drift detectors has resulted in an unprecedented improvement in detection efficiency for energy-dispersive X-ray (EDX) spectroscopy in the scanning transmission electron microscope. The result is numerous beautiful atomic-scale maps, which provide insights into the internal structure of a variety of materials. However, the task still remains to understand exactly where the X-ray signal comes from and how accurately it can be quantified. Unfortunately, when crystals are aligned with a low-order zone axis parallel to the incident beam direction, as is necessary for atomic-resolution imaging, the electron beam channels. When the beam becomes localized in this way, the relationship between the concentration of a particular element and its spectroscopic X-ray signal is generally nonlinear. Here, we discuss the combined effect of both spatial integration and sample tilt for ameliorating the effects of channeling and improving the accuracy of EDX quantification. Both simulations and experimental results will be presented for a perovskite-based oxide interface. We examine how the scattering and spreading of the electron beam can lead to erroneous interpretation of interface compositions, and what approaches can be made to improve our understanding of the underlying atomic structure. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000664532400007 |
Publication Date |
2021-04-12 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
1.891 |
Times cited |
|
Open Access |
OpenAccess |
Notes |
The authors would like to thank Jürgen Schubert for helping to supply the sample and valuable discussions on the topic. K. E. MacArthur and M. Heggen acknowledge the Helmholtz Funding agency and the DFG (grant number HE 7192/1-2) for their financial support of this work. L. J. Allen acknowledges the support of the Alexander von Humboldt Foundation. This research was supported under the Discovery Projects funding scheme of the Australian Research Council (Projects DP140102538 and FT190100619). K.E. MacArthur, A.B. Yankovich and A. Béché acknowledge support from the European Union’s Horizon 2020 research innovation program under grant agreement No. 823717 – ESTEEM3. A.B. Yankovich also acknowledges support from the Materials Science Area of Advance at Chalmers and the Swedish Research Council (VR, under grant No: 2020-04986).; esteem3TA; esteem3reported |
Approved |
Most recent IF: 1.891 |
Call Number |
EMAT @ emat @c:irua:178129 |
Serial |
6760 |
Permanent link to this record |
|
|
|
Author |
Esteban, D.A.; Vanrompay, H.; Skorikov, A.; Béché, A.; Verbeeck, J.; Freitag, B.; Bals, S. |
Title |
Fast electron low dose tomography for beam sensitive materials |
Type |
A1 Journal article |
Year |
2021 |
Publication |
Microscopy And Microanalysis |
Abbreviated Journal |
Microsc Microanal |
Volume |
27 |
Issue |
S1 |
Pages |
2116-2118 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
|
Publication Date |
2021-07-30 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
UA library record |
Impact Factor |
1.891 |
Times cited |
|
Open Access |
OpenAccess |
Notes |
|
Approved |
Most recent IF: 1.891 |
Call Number |
EMAT @ emat @c:irua:183278 |
Serial |
6813 |
Permanent link to this record |
|
|
|
Author |
Neelisetty, K.K.; Kumar C.N., S.; Kashiwar, A.; Scherer, T.; Chakravadhanula, V.S.K.; Kuebel, C. |
Title |
Novel thin film lift-off process for in situ TEM tensile characterization |
Type |
A1 Journal article |
Year |
2021 |
Publication |
Microscopy And Microanalysis |
Abbreviated Journal |
Microsc Microanal |
Volume |
27 |
Issue |
S1 |
Pages |
216-217 |
Keywords |
A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
|
Publication Date |
2021-07-30 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
UA library record |
Impact Factor |
1.891 |
Times cited |
|
Open Access |
Not_Open_Access |
Notes |
|
Approved |
Most recent IF: 1.891 |
Call Number |
UA @ admin @ c:irua:183617 |
Serial |
6873 |
Permanent link to this record |
|
|
|
Author |
Ning, S.; Xu, W.; Ma, Y.; Loh, L.; Pennycook, T.J.; Zhou, W.; Zhang, F.; Bosman, M.; Pennycook, S.J.; He, Q.; Loh, N.D. |
Title |
Accurate and Robust Calibration of the Uniform Affine Transformation Between Scan-Camera Coordinates for Atom-Resolved In-Focus 4D-STEM Datasets |
Type |
A1 Journal article |
Year |
2022 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
Volume |
|
Issue |
|
Pages |
1-11 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
Accurate geometrical calibration between the scan coordinates and the camera coordinates is critical in four-dimensional scanning transmission electron microscopy (4D-STEM) for both quantitative imaging and ptychographic reconstructions. For atomic-resolved, in-focus 4D-STEM datasets, we propose a hybrid method incorporating two sub-routines, namely a J-matrix method and a Fourier method, which can calibrate the uniform affine transformation between the scan-camera coordinates using raw data, without a priori knowledge about the crystal structure of the specimen. The hybrid method is found robust against scan distortions and residual probe aberrations. It is also effective even when defects are present in the specimen, or the specimen becomes relatively thick. We will demonstrate that a successful geometrical calibration with the hybrid method will lead to a more reliable recovery of both the specimen and the electron probe in a ptychographic reconstruction. We will also show that, although the elimination of local scan position errors still requires an iterative approach, the rate of convergence can be improved, and the residual errors can be further reduced if the hybrid method can be firstly applied for initial calibration. The code is made available as a simple-to-use tool to correct affine transformations of the scan-camera coordinates in 4D-STEM experiments. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000767045700001 |
Publication Date |
2022-03-09 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.8 |
Times cited |
|
Open Access |
OpenAccess |
Notes |
N. D. Loh kindly acknowledges support from NUS Early Career Research Award (R-154-000-B35-133), MOE’s AcRF Tier 1 grant nr. R-284-000-172-114 and NRF CRP grant number NRF-CRP16-2015-05. Q. He would also like to acknowledge the support of the National Research Foundation (NRF) Singapore, under its NRF Fellowship (NRF-NRFF11-2019-0002). W. Zhou acknowledges the support from Beijing Outstanding Young Scientist Program (BJJWZYJH01201914430039). F. Zhang acknowledges the support of the National Natural Science Foundation of China (11775105, 12074167). T. J. Pennycook acknowledges funding under the European Union’s Horizon 2020 research and innovation programme from the European Research Council (ERC) Grant agreement No. 802123-HDEM. |
Approved |
Most recent IF: 2.8 |
Call Number |
EMAT @ emat @c:irua:186958 |
Serial |
6957 |
Permanent link to this record |
|
|
|
Author |
Yu, C.-P.; Friedrich, T.; Jannis, D.; Van Aert, S.; Verbeeck, J. |
Title |
Real-Time Integration Center of Mass (riCOM) Reconstruction for 4D STEM |
Type |
A1 Journal article |
Year |
2022 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
Volume |
|
Issue |
|
Pages |
1-12 |
Keywords |
A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT) |
Abstract |
A real-time image reconstruction method for scanning transmission electron microscopy (STEM) is proposed. With an algorithm requiring only the center of mass of the diffraction pattern at one probe position at a time, it is able to update the resulting image each time a new probe position is visited without storing any intermediate diffraction patterns. The results show clear features at high spatial frequency, such as atomic column positions. It is also demonstrated that some common post-processing methods, such as band-pass filtering, can be directly integrated in the real-time processing flow. Compared with other reconstruction methods, the proposed method produces high-quality reconstructions with good noise robustness at extremely low memory and computational requirements. An efficient, interactive open source implementation of the concept is further presented, which is compatible with frame-based, as well as event-based camera/file types. This method provides the attractive feature of immediate feedback that microscope operators have become used to, for example, conventional high-angle annular dark field STEM imaging, allowing for rapid decision-making and fine-tuning to obtain the best possible images for beam-sensitive samples at the lowest possible dose. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000792176100001 |
Publication Date |
2022-04-25 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.8 |
Times cited |
7 |
Open Access |
OpenAccess |
Notes |
Bijzonder Onderzoeksfonds UGent; H2020 European Research Council, 770887 ; H2020 European Research Council, 823717 ; H2020 European Research Council, ESTEEM3 / 823717 ; H2020 European Research Council, PICOMETRICS / 770887 ; Fonds Wetenschappelijk Onderzoek, 30489208 ; Herculesstichting; esteem3reported; esteem3jra |
Approved |
Most recent IF: 2.8 |
Call Number |
EMAT @ emat @c:irua:188538 |
Serial |
7068 |
Permanent link to this record |
|
|
|
Author |
De wael, A.; De Backer, A.; Yu, C.-P.; Sentürk, D.G.; Lobato, I.; Faes, C.; Van Aert, S. |
Title |
Three Approaches for Representing the Statistical Uncertainty on Atom-Counting Results in Quantitative ADF STEM |
Type |
A1 Journal article |
Year |
2022 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
Volume |
|
Issue |
|
Pages |
1-9 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
A decade ago, a statistics-based method was introduced to count the number of atoms from annular dark-field scanning transmission electron microscopy (ADF STEM) images. In the past years, this method was successfully applied to nanocrystals of arbitrary shape, size, and composition (and its high accuracy and precision has been demonstrated). However, the counting results obtained from this statistical framework are so far presented without a visualization of the actual uncertainty about this estimate. In this paper, we present three approaches that can be used to represent counting results together with their statistical error, and discuss which approach is most suited for further use based on simulations and an experimental ADF STEM image. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000854930500001 |
Publication Date |
2022-09-19 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
UA library record; WoS full record |
Impact Factor |
2.8 |
Times cited |
|
Open Access |
OpenAccess |
Notes |
This project has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (Grant Agreement No. 770887 and No. 823717 ESTEEM3). The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through grants to A.D.w. and A.D.B. and projects G.0502.18N, G.0267.18N, and EOS 30489208. S.V.A. acknowledges TOP BOF funding from the University of Antwerp. The authors are grateful to L.M. Liz-Marzán (CIC biomaGUNE and Ikerbasque) for providing the samples. esteem3reported; esteem3jra |
Approved |
Most recent IF: 2.8 |
Call Number |
EMAT @ emat @c:irua:190585 |
Serial |
7119 |
Permanent link to this record |
|
|
|
Author |
Vega Ibañez, F.; Béché, A.; Verbeeck, J. |
Title |
Can a programmable phase plate serve as an aberration corrector in the transmission electron microscope (TEM)? |
Type |
A1 Journal article |
Year |
2022 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
Volume |
|
Issue |
|
Pages |
Pii S1431927622012260-10 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
Current progress in programmable electrostatic phase plates raises questions about their usefulness for specific applications. Here, we explore different designs for such phase plates with the specific goal of correcting spherical aberration in the transmission electron microscope (TEM). We numerically investigate whether a phase plate could provide down to 1 angstrom ngstrom spatial resolution on a conventional uncorrected TEM. Different design aspects (fill factor, pixel pattern, symmetry) were evaluated to understand their effect on the electron probe size and current density. Some proposed designs show a probe size () down to 0.66 angstrom, proving that it should be possible to correct spherical aberration well past the 1 angstrom limit using a programmable phase plate consisting of an array of electrostatic phase-shifting elements. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000849975400001 |
Publication Date |
2022-09-21 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.8 |
Times cited |
3 |
Open Access |
OpenAccess |
Notes |
All authors acknowledge funding from the Flemish Research Fund under contract G042820N “Exploring adaptive optics in transmission electron microscopy”. J.V. acknowledges funding from the European Union’s Horizon 2020 Research Infrastructure – Integrating Activities for Advanced Communities under grant agreement No 823717 – ESTEEM3 and from the University of Antwerp through a TOP BOF project.; esteem3reported; esteem3jra |
Approved |
Most recent IF: 2.8 |
Call Number |
UA @ admin @ c:irua:190627 |
Serial |
7134 |
Permanent link to this record |
|
|
|
Author |
Friedrich, T.; Yu, C.-P.; Verbeeck, J.; Van Aert, S. |
Title |
Phase object reconstruction for 4D-STEM using deep learning |
Type |
A1 Journal article |
Year |
2023 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
|
Volume |
29 |
Issue |
1 |
Pages |
395-407 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
In this study, we explore the possibility to use deep learning for the reconstruction of phase images from 4D scanning transmission electron microscopy (4D-STEM) data. The process can be divided into two main steps. First, the complex electron wave function is recovered for a convergent beam electron diffraction pattern (CBED) using a convolutional neural network (CNN). Subsequently, a corresponding patch of the phase object is recovered using the phase object approximation. Repeating this for each scan position in a 4D-STEM dataset and combining the patches by complex summation yields the full-phase object. Each patch is recovered from a kernel of 3x3 adjacent CBEDs only, which eliminates common, large memory requirements and enables live processing during an experiment. The machine learning pipeline, data generation, and the reconstruction algorithm are presented. We demonstrate that the CNN can retrieve phase information beyond the aperture angle, enabling super-resolution imaging. The image contrast formation is evaluated showing a dependence on the thickness and atomic column type. Columns containing light and heavy elements can be imaged simultaneously and are distinguishable. The combination of super-resolution, good noise robustness, and intuitive image contrast characteristics makes the approach unique among live imaging methods in 4D-STEM. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
001033590800038 |
Publication Date |
2023-01-12 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.8 |
Times cited |
1 |
Open Access |
OpenAccess |
Notes |
We acknowledge funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation program (grant agreement no. 770887 PICOMETRICS) and funding from the European Union's Horizon 2020 research and innovation program under grant agreement No. 823717 ESTEEM3. J.V. and S.V.A acknowledge funding from the University of Antwerp through a TOP BOF project. The direct electron detector (Merlin, Medipix3, Quantum Detectors) was funded by the Hercules fund from the Flemish Government. This work was supported by the FWO and FNRS within the 2Dto3D project of the EOS program (grant number 30489208). |
Approved |
Most recent IF: 2.8; 2023 IF: 1.891 |
Call Number |
UA @ admin @ c:irua:198221 |
Serial |
8912 |
Permanent link to this record |
|
|
|
Author |
Müller, E.; Kruse, P.; Gerthsen, D.; Schowalter, M.; Rosenauer, A.; Lamoen, D.; Kling, R. |
Title |
Measurement of the mean inner potential of ZnO nanorods by transmission electron holography |
Type |
A1 Journal article |
Year |
2005 |
Publication |
Microscopy of Semiconducting Materials |
Abbreviated Journal |
|
Volume |
107 |
Issue |
|
Pages |
303-306 |
Keywords |
A1 Journal article; Electron Microscopy for Materials Science (EMAT) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Berlin |
Editor |
|
Language |
|
Wos |
|
Publication Date |
0000-00-00 |
Series Editor |
|
Series Title |
SPRINGER PROCEEDINGS IN PHYSICS |
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0930-8989 |
ISBN |
|
Additional Links |
UA library record; WoS full record; |
Impact Factor |
|
Times cited |
|
Open Access |
|
Notes |
|
Approved |
Most recent IF: NA |
Call Number |
UA @ lucian @ c:irua:72914 |
Serial |
1962 |
Permanent link to this record |
|
|
|
Author |
Schryvers, D.; Goessens, C.; Safran, G.; Toth, L. |
Title |
Internal calibration technique for HREM studies of nanoscale particles |
Type |
A1 Journal article |
Year |
1993 |
Publication |
Microscopy research and technique
T2 – JOINT MEETING OF DUTCH SOC FOR ELECTRON MICROSCOPY / BELGIAN SOC FOR, ELECTRON MICROSCOPY / BELGIAN SOC FOR CELL BIOLOGY, DEC 10-11, 1992, ANTWERP, BELGIUM |
Abbreviated Journal |
Microsc Res Techniq |
Volume |
25 |
Issue |
2 |
Pages |
185-186 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
New York, N.Y. |
Editor |
|
Language |
|
Wos |
A1993LB60700015 |
Publication Date |
2005-02-23 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1059-910X;1097-0029; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
1.154 |
Times cited |
1 |
Open Access |
|
Notes |
|
Approved |
no |
Call Number |
UA @ lucian @ c:irua:104488 |
Serial |
1700 |
Permanent link to this record |
|
|
|
Author |
Montoya, E.; Bals, S.; Rossell, M.D.; Schryvers, D.; Van Tendeloo, G. |
Title |
Evaluation of top, angle, and side cleaned FIB samples for TEM analysis |
Type |
A1 Journal article |
Year |
2007 |
Publication |
Microscopy research and technique |
Abbreviated Journal |
Microsc Res Techniq |
Volume |
70 |
Issue |
12 |
Pages |
1060-1071 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
ITEM specimens of a LaAlO3/SrTiO3 multilayer are prepared by FIB with internal lift out. Using a Ga+1 beam of 5 kV, a final cleaning step yielding top, top-angle, side, and bottom-angle cleaning is performed. Different cleaning procedures, which can be easily implemented in a dual beam FIB system, are described and compared; all cleaning types produce thin lamellae, useful for HRTEM and HAADF-STEM work up to atomic resolution. However, the top cleaned lamellae are strongly affected by the curtain effect. Top-angle cleaned specimens show an amorphous layer of around 5 nm at the specimen surfaces, due to damage and redeposition. Furthermore, it is observed that the LaAlO3 layers are preferentially destroyed and transformed into amorphous material, during the thinning process. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
New York, N.Y. |
Editor |
|
Language |
|
Wos |
000251868200008 |
Publication Date |
2007-08-25 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1059-910X;1097-0029; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
1.147 |
Times cited |
36 |
Open Access |
|
Notes |
Aip; Fwo |
Approved |
Most recent IF: 1.147; 2007 IF: 1.644 |
Call Number |
UA @ lucian @ c:irua:67282 |
Serial |
1090 |
Permanent link to this record |
|
|
|
Author |
Bertoni, G.; Verbeeck, J.; Brosens, F. |
Title |
Fitting the momentum dependent loss function in EELS |
Type |
A1 Journal article |
Year |
2011 |
Publication |
Microscopy research and technique |
Abbreviated Journal |
Microsc Res Techniq |
Volume |
74 |
Issue |
3 |
Pages |
212-218 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Theory of quantum systems and complex systems |
Abstract |
Momentum dependent inelastic plasmon scattering can be measured by electron energy loss in a transmission electron microscope. From energy filtered diffraction, the characteristic angle of scattering and the cutoff angle are measured, using a thin film of aluminum as a model test. Rather than deconvolving the data (as done in previous works), a fitting technique is used to extract the loss function from angular resolved spectra, starting from a simple model simulation. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
New York, N.Y. |
Editor |
|
Language |
|
Wos |
000288095200002 |
Publication Date |
2010-07-06 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1059-910X; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
1.147 |
Times cited |
6 |
Open Access |
|
Notes |
Fwo; Esteem; Iap; Goa |
Approved |
Most recent IF: 1.147; 2011 IF: 1.792 |
Call Number |
UA @ lucian @ c:irua:88782UA @ admin @ c:irua:88782 |
Serial |
1222 |
Permanent link to this record |
|
|
|
Author |
Zelaya, E.; Schryvers, D. |
Title |
Reducing the formation of FIB-induced FCC layers on Cu-Zn-Al austenite |
Type |
A1 Journal article |
Year |
2011 |
Publication |
Microscopy research and technique |
Abbreviated Journal |
Microsc Res Techniq |
Volume |
74 |
Issue |
1 |
Pages |
84-91 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
The irradiation effects of thinning a sample of a Cu-Zn-Al shape memory alloy to electron transparency by a Ga+ focused ion beam were investigated. This thinning method was compared with conventional electropolishing and Ar+ ion milling. No implanted Ga was detected but surface FCC precipitation was found as a result of the focused ion beam sample preparation. Decreasing the irradiation dose by lowering the energy and current of the Ga+ ions did not lead to a complete disappearance of the FCC structure. The latter could only be removed after gentle Ar+ ion milling of the sample. It was further concluded that the precipitation of the FCC is independent of the crystallographic orientation of the surface. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
New York, N.Y. |
Editor |
|
Language |
|
Wos |
000285976000012 |
Publication Date |
2010-05-25 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1059-910X; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
1.147 |
Times cited |
2 |
Open Access |
|
Notes |
|
Approved |
Most recent IF: 1.147; 2011 IF: 1.792 |
Call Number |
UA @ lucian @ c:irua:85994 |
Serial |
2852 |
Permanent link to this record |
|
|
|
Author |
Van Tendeloo, G.; Krekels, T.; Amelinckx, S.; Babu, T.G.N.; Greaves, C.; Hervieu, M.; Michel, C.; Raveau, B. |
Title |
Structural investigations of recently discovered high Tc superconductors |
Type |
A1 Journal article |
Year |
1995 |
Publication |
Microscopy research and technique |
Abbreviated Journal |
Microsc Res Techniq |
Volume |
30 |
Issue |
|
Pages |
102-122 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
New York, N.Y. |
Editor |
|
Language |
|
Wos |
A1995QH52800002 |
Publication Date |
2005-02-23 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1059-910X;1097-0029; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
1.154 |
Times cited |
4 |
Open Access |
|
Notes |
|
Approved |
MATERIALS SCIENCE, MULTIDISCIPLINARY 135/271 Q2 # PHYSICS, APPLIED 70/145 Q2 # PHYSICS, CONDENSED MATTER 40/67 Q3 # |
Call Number |
UA @ lucian @ c:irua:13307 |
Serial |
3241 |
Permanent link to this record |
|
|
|
Author |
De Meulenaere, P.; Van Tendeloo, G.; van Landuyt, J. |
Title |
The study of partially ordered 11/20 alloys by HREM |
Type |
A1 Journal article |
Year |
1993 |
Publication |
Microscopy research and technique |
Abbreviated Journal |
Microsc Res Techniq |
Volume |
25 |
Issue |
|
Pages |
169-170 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
New York, N.Y. |
Editor |
|
Language |
|
Wos |
A1993LB60700007 |
Publication Date |
2005-02-23 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1059-910X;1097-0029; |
ISBN |
|
Additional Links |
UA library record; WoS full record |
Impact Factor |
1.154 |
Times cited |
|
Open Access |
|
Notes |
|
Approved |
PHYSICS, APPLIED 28/145 Q1 # |
Call Number |
UA @ lucian @ c:irua:6785 |
Serial |
3331 |
Permanent link to this record |
|
|
|
Author |
Goessens, C.; Schryvers, D.; van Landuyt, J. |
Title |
Transmission electron microscopy studies of (111) twinned silver halide microcrystals |
Type |
A1 Journal article |
Year |
1998 |
Publication |
Microscopy research and technique |
Abbreviated Journal |
Microsc Res Techniq |
Volume |
42 |
Issue |
|
Pages |
85-99 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
New York, N.Y. |
Editor |
|
Language |
|
Wos |
000075521300003 |
Publication Date |
2002-08-25 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1059-910X;1097-0029; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
1.147 |
Times cited |
8 |
Open Access |
|
Notes |
|
Approved |
Most recent IF: 1.147; 1998 IF: 0.765 |
Call Number |
UA @ lucian @ c:irua:29676 |
Serial |
3713 |
Permanent link to this record |
|
|
|
Author |
Pourbabak, S.; Orekhov, A.; Schryvers, D. |
Title |
Twin-jet electropolishing for damage-free transmission electron microscopy specimen preparation of metallic microwires |
Type |
A1 Journal article |
Year |
2020 |
Publication |
Microscopy Research And Technique |
Abbreviated Journal |
Microsc Res Techniq |
Volume |
|
Issue |
|
Pages |
1-7 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
A method to prepare TEM specimens from metallic microwires and based on conventional twin-jet electropolishing is introduced. The wire is embedded in an opaque epoxy resin medium and the hardened resin is mechanically polished to reveal the wire on both sides. The resin containing wire is then cut into discs of the appropriate size. The obtained embedded wire is electropolished in a conventional twin-jet electropolishing machine until electron transparency in large areas without radiation damage is achieved. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000567944200001 |
Publication Date |
2020-09-28 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1059-910x |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.5 |
Times cited |
|
Open Access |
OpenAccess |
Notes |
; Fonds Wetenschappelijk Onderzoek, Grant/Award Number: G.0366.15N ; |
Approved |
Most recent IF: 2.5; 2020 IF: 1.147 |
Call Number |
UA @ admin @ c:irua:171969 |
Serial |
6642 |
Permanent link to this record |
|
|
|
Author |
Verbist, K.; Van Tendeloo, G.; Ye, M.; Schroeder, J.; Mehbod, M.; Deltour, R. |
Title |
Inclusions in magnetron sputtered YBa2Cu3-x MxO7-d thin films: a study by means of electron microscopy |
Type |
A1 Journal article |
Year |
1996 |
Publication |
Microscopy, microanalysis, microstructures |
Abbreviated Journal |
|
Volume |
7 |
Issue |
|
Pages |
17-25 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Ivry |
Editor |
|
Language |
|
Wos |
A1996UD94200002 |
Publication Date |
2003-08-13 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1154-2799; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
|
Times cited |
6 |
Open Access |
|
Notes |
|
Approved |
no |
Call Number |
UA @ lucian @ c:irua:15463 |
Serial |
1592 |
Permanent link to this record |
|
|
|
Author |
Hervieu; Van Tendeloo, G.; Michel; Pelloquin; Raveau |
Title |
Mixed layers in copper based superconducting materials |
Type |
A1 Journal article |
Year |
1996 |
Publication |
Microscopy, microanalysis, microstructures |
Abbreviated Journal |
|
Volume |
7 |
Issue |
2 |
Pages |
107-141 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
Recently discovered series of high Tc superconductors, characterized by the existence of two types of cations within the same layer, are presented. The first family concerns the mercury based cuprates, Hg(1-x)M(x)A(2)Ca(m-1)Cu(m)O(2m+2+delta), with A = Ba and/or Sr, which exhibit structures closely related to that of the thallium cuprates TlBa2Cam-1CumO2m+3. They differ from the thallium cuprates by a high oxygen deficiency at the level of the mercury layer. It is shown that cations such as M = Cu, Pb, Tl, Bi, Ce, Pr, Cr, V, Mo, W, Ti, Sr, Ca,... can partially substitute for mercury ions, stabilizing the structures. The cationic composition of the layer depends indeed on the nature of the M cation but also on that of the alkaline earth A. For given A and M cations, the a: value remains unchanged even when the number of copper layers varies. M and Hg cations are either statistically distributed over the same site or ordered. Different types of ordering have been detected. Another way of generating mixed layers is to shear periodically the structure, leading to the formation of the so called ''collapsed phase''. In the collapsed bismuth cuprates, bismuth and copper segments, a few octahedra long, alternate in strongly waving layers. In the collapsed oxycarbonates, carbonate groups and M cations are ordered within the intermediate layer so that they can be simply described from a partial and ordered substitution of carbon for Hg,TI, Bi and other M cations building the intermediate layer. The oxycarbonitrates (Y1-xCax)(n)Ba2nCu3n-1(C,N)O3O7n-3 can also be described as an ordered substitution of carbon for copper in the 123 matrix. The different families of superconducting materials which are generated by such mechanisms are described as well as the way the different species are distributed within the mixed layers. Their influence on the physical properties are discussed. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Ivry |
Editor |
|
Language |
|
Wos |
A1996VA22000004 |
Publication Date |
2003-08-13 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1154-2799; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
|
Times cited |
2 |
Open Access |
|
Notes |
|
Approved |
no |
Call Number |
UA @ lucian @ c:irua:95287 |
Serial |
2088 |
Permanent link to this record |
|
|
|
Author |
van Dyck, D.; Van Aert, S.; Croitoru, M.D. |
Title |
Obstacles on the road towards atomic resolution tomography |
Type |
A3 Journal article |
Year |
2005 |
Publication |
Microscoy and microanalysis |
Abbreviated Journal |
|
Volume |
11 |
Issue |
S2 |
Pages |
238-239 |
Keywords |
A3 Journal article; Electron microscopy for materials research (EMAT); Condensed Matter Theory (CMT); Vision lab |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
|
Publication Date |
0000-00-00 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Additional Links |
UA library record |
Impact Factor |
|
Times cited |
|
Open Access |
|
Notes |
|
Approved |
Most recent IF: NA |
Call Number |
UA @ lucian @ c:irua:57129 |
Serial |
2426 |
Permanent link to this record |
|
|
|
Author |
Van Tendeloo, G. |
Title |
TEM of phase transitions in tridymite and cristobalite based materials |
Type |
A3 Journal article |
Year |
2000 |
Publication |
Microscoy and microanalysis |
Abbreviated Journal |
|
Volume |
6 |
Issue |
S2 |
Pages |
|
Keywords |
A3 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
|
Publication Date |
0000-00-00 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Additional Links |
UA library record |
Impact Factor |
|
Times cited |
|
Open Access |
|
Notes |
|
Approved |
Most recent IF: NA |
Call Number |
UA @ lucian @ c:irua:54726 |
Serial |
3483 |
Permanent link to this record |
|
|
|
Author |
Giorgio, S.; Henry, C.R.; Pauwels, B.; Van Tendeloo, G. |
Title |
Au particles supported on (110) anatase-TiO2 |
Type |
A1 Journal article |
Year |
2001 |
Publication |
Microstructure And Processing |
Abbreviated Journal |
Mat Sci Eng A-Struct |
Volume |
297 |
Issue |
1-2 |
Pages |
197-202 |
Keywords |
A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT) |
Abstract |
Au particles were prepared by evaporation in ultra high vacuum at high temperature, on the surfaces of TiO2 micro-spheres with the anatase structure. The morphology and the structural deformation in Au deposits were studied by high resolution transmission electron microscopy and image simulations by the multislice technique. The particles were polyhedral, limited by (100) and (111) faces. Patches with a hexagonal lattice were found around the particles, which was interpreted as thin Au islands on the surface. In these islands the Au lattice was deformed and perfectly accommodated to the (110) surface of TiO2. (C) 2001 Elsevier Science B.V. All rights reserved. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Lausanne |
Editor |
|
Language |
|
Wos |
000166241400026 |
Publication Date |
2002-07-25 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0921-5093; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
3.094 |
Times cited |
40 |
Open Access |
|
Notes |
|
Approved |
Most recent IF: 3.094; 2001 IF: 0.978 |
Call Number |
UA @ lucian @ c:irua:104204 |
Serial |
206 |
Permanent link to this record |
|
|
|
Author |
Weng, Y.; Jia, Z.; Ding, L.; Muraishi, S.; Liu, Q. |
Title |
Clustering behavior during natural aging and artificial aging in Al-Mg-Si alloys with different Ag and Cu addition |
Type |
A1 Journal article |
Year |
2018 |
Publication |
Microstructure And Processing |
Abbreviated Journal |
Mat Sci Eng A-Struct |
Volume |
732 |
Issue |
732 |
Pages |
273-283 |
Keywords |
A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT) |
Abstract |
The effect of Ag and Cu addition on clustering behavior of Al-Mg-Si alloys during natural aging (NA) and artificial aging (AA) was investigated by hardness measurement, tensile test and atom probe tomography analysis. The results show that both Ag and Cu atoms could enter clusters and GP-zones, change the Mg/Si ratio and increase their volume fractions. Compared with the Al base alloy, the clusters in the Ag/Cu-added alloys more easily transform to beta" phases for size and compositional similarity, and the strengthening ability of these particles is enhanced by the increased volume fraction and shear modulus. In NA condition, Cu is greater in improving the volume fraction of clusters than Ag and thus produces higher T4 temper hardness. In AA condition, in contrary, Ag is more effective in facilitating the formation and growth of particles than Cu due to the stronger Ag-Mg interaction and the high diffusivity of Ag atoms in Al matrix, leading to highest hardening response. Compared to the Cu-added alloy, the Ag-added alloy shows higher precipitation kinetics during AA treatment and maintains a lower T4 temper hardness. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Lausanne |
Editor |
|
Language |
|
Wos |
000441486100032 |
Publication Date |
2018-07-07 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0921-5093 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
3.094 |
Times cited |
11 |
Open Access |
OpenAccess |
Notes |
; This work was supported by the Special major R & D Projects for Key Technology Innovation of Key Industries in Chongqing (Grant no. cstc2017zdcy-zdzxX0006), the Fundamental Research Funds for the Central Universities of China (Grant no. 106112016CDJXZ338825 and 106112017CDJQJ308822) and the program of China Scholarships Council (No. 201706050125). ; |
Approved |
Most recent IF: 3.094 |
Call Number |
UA @ lucian @ c:irua:153107 |
Serial |
5083 |
Permanent link to this record |