|
“Resolution of coherent and incoherent imaging systems reconsidered: classical criteria and a statistical alternative”. Van Aert S, van Dyck D, den Dekker AJ, Optics express 14, 3830 (2006). http://doi.org/10.1364/OE.14.003830
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 3.307
Times cited: 45
DOI: 10.1364/OE.14.003830
|
|
|
“Ni cluster formation in low temperature annealed Ni50.6Ti49.4”. Pourbabak S, Wang X, Van Dyck D, Verlinden B, Schryvers D, Functional materials letters 10, 1740005 (2017). http://doi.org/10.1142/S1793604717400057
Abstract: Various low temperature treatments of Ni50.6Ti49.4 have shown an unexpected effect on the martensitic start temperature. Periodic diffuse intensity distributions in reciprocal space indicate the formation of short pure Ni strings along the <111> directions in the B2 ordered lattice, precursing the formation of Ni4Ti3 precipitates formed at higher annealing temperatures.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 1.234
Times cited: 4
DOI: 10.1142/S1793604717400057
|
|
|
“An accurate parameterization for scattering factors, electron densities and electrostatic potentials for neutral atoms that obey all physical constraints”. Lobato Hoyos IP, van Dyck D, Acta crystallographica: section A: foundations of crystallography 70, 636 (2014). http://doi.org/10.1107/S205327331401643X
Abstract: An efficient procedure and computer program are outlined for fitting numerical X-ray and electron scattering factors with the correct inclusion of all physical constraints. The numerical electron scattering factors have been parameterized using five analytic non-relativistic hydrogen electron scattering factors as basis functions for 103 neutral atoms of the periodic table. The inclusion of the correct physical constraints in the electron scattering factor and its derived quantities allows the use of the new parameterization in different fields. In terms of quality of the fit, the proposed parameterization of the electron scattering factor is one order of magnitude better than the previous analytic fittings.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 5.725
Times cited: 19
DOI: 10.1107/S205327331401643X
|
|
|
“Advanced electron crystallography through model-based imaging”. Van Aert S, De Backer A, Martinez GT, den Dekker AJ, Van Dyck D, Bals S, Van Tendeloo G, IUCrJ 3, 71 (2016). http://doi.org/10.1107/S2052252515019727
Abstract: The increasing need for precise determination of the atomic arrangement of non-periodic structures in materials design and the control of nanostructures explains the growing interest in quantitative transmission electron microscopy. The aim is to extract precise and accurate numbers for unknown structure parameters including atomic positions, chemical concentrations and atomic numbers. For this purpose, statistical parameter estimation theory has been shown to provide reliable results. In this theory, observations are considered purely as data planes, from which structure parameters have to be determined using a parametric model describing the images. As such, the positions of atom columns can be measured with a precision of the order of a few picometres, even though the resolution of the electron microscope is still one or two orders of magnitude larger. Moreover, small differences in average atomic number, which cannot be distinguished visually, can be quantified using high-angle annular dark-field scanning transmission electron microscopy images. In addition, this theory allows one to measure compositional changes at interfaces, to count atoms with single-atom sensitivity, and to reconstruct atomic structures in three dimensions. This feature article brings the reader up to date, summarizing the underlying theory and highlighting some of the recent applications of quantitative model-based transmisson electron microscopy.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab; Engineering Management (ENM)
Impact Factor: 5.793
Times cited: 30
DOI: 10.1107/S2052252515019727
|
|
|
“Statistical method for thickness measurement of amorphous objects”. van Dyck D, Croitoru MD, Applied physics letters 90, 241911 (2007). http://doi.org/10.1063/1.2749184
Abstract: The authors propose a nondestructive method for the determination of the thickness of an amorphous sample. This method is based on the statistics of the phase of the electron exit wave function, which depend on the number of atoms traversed by the incident electron which itself is a function of the thickness of the object. The accuracy of this method has been checked numerically by the multislice method and compared with that based on the mean inner potential. (c) 2007 American Institute of Physics.
Keywords: A1 Journal article; Condensed Matter Theory (CMT); Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 3.411
Times cited: 4
DOI: 10.1063/1.2749184
|
|
|
“Hollow Cone Electron Imaging for Single Particle 3D Reconstruction of Proteins”. Tsai C-Y, Chang Y-C, Lobato I, Van Dyck D, Chen F-R, Scientific reports 6, 27701 (2016). http://doi.org/10.1038/srep27701
Abstract: The main bottlenecks for high-resolution biological imaging in electron microscopy are radiation sensitivity and low contrast. The phase contrast at low spatial frequencies can be enhanced by using a large defocus but this strongly reduces the resolution. Recently, phase plates have been developed to enhance the contrast at small defocus but electrical charging remains a problem. Single particle cryo-electron microscopy is mostly used to minimize the radiation damage and to enhance the resolution of the 3D reconstructions but it requires averaging images of a massive number of individual particles. Here we present a new route to achieve the same goals by hollow cone dark field imaging using thermal diffuse scattered electrons giving about a 4 times contrast increase as compared to bright field imaging. We demonstrate the 3D reconstruction of a stained GroEL particle can yield about 13.5 A resolution but using a strongly reduced number of images.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 4.259
DOI: 10.1038/srep27701
|
|
|
“Atomic resolution mapping using quantitative high-angle annular dark field scanning transmission electron microscopy”. Van Aert S, Verbeeck J, Bals S, Erni R, van Dyck D, Van Tendeloo G, Microscopy and microanalysis 15, 464 (2009). http://doi.org/10.1017/S1431927609093957
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 1.891
Times cited: 1
DOI: 10.1017/S1431927609093957
|
|
|
“Dynamical diffraction of high-energy electrons investigated by focal series momentum-resolved scanning transmission electron microscopy at atomic resolution”. Robert Hl, Lobato I, Lyu Fj, Chen Q, Van Aert S, Van Dyck D, Müller-Caspary K, Ultramicroscopy 233, 113425 (2022). http://doi.org/10.1016/j.ultramic.2021.113425
Abstract: We report a study of scattering dynamics in crystals employing momentum-resolved scanning transmission
electron microscopy under varying illumination conditions. As we perform successive changes of the probe
focus, multiple real-space signals are obtained in dependence of the shape of the incident electron wave.
With support from extensive simulations, each signal is shown to be characterised by an optimum focus for
which the contrast is maximum and which differs among different signals. For instance, a systematic focus
mismatch is found between images formed by high-angle scattering, being sensitive to thickness and chemical
composition, and the first moment in diffraction space, being sensitive to electric fields. It follows that a single
recording at one specific probe focus is usually insufficient to characterise materials comprehensively. Most
importantly, we demonstrate in experiment and simulation that the second moment (
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.2
DOI: 10.1016/j.ultramic.2021.113425
|
|
|
“How precise can atoms of a nanocluster be located in 3D using a tilt series of scanning transmission electron microscopy images?”.Alania M, De Backer A, Lobato I, Krause FF, Van Dyck D, Rosenauer A, Van Aert S, Ultramicroscopy 181, 134 (2017). http://doi.org/10.1016/j.ultramic.2016.12.013
Abstract: In this paper, we investigate how precise atoms of a small nanocluster can ultimately be located in three dimensions (3D) from a tilt series of images acquired using annular dark field (ADF) scanning transmission electron microscopy (STEM). Therefore, we derive an expression for the statistical precision with which the 3D atomic position coordinates can be estimated in a quantitative analysis. Evaluating this statistical precision as a function of the microscope settings also allows us to derive the optimal experimental design. In this manner, the optimal angular tilt range, required electron dose, optimal detector angles, and number of projection images can be determined.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 3
DOI: 10.1016/j.ultramic.2016.12.013
|
|
|
“A memory efficient method for fully three-dimensional object reconstruction with HAADF STEM”. Van den Broek W, Rosenauer A, Van Aert S, Sijbers J, van Dyck D, Ultramicroscopy 141, 22 (2014). http://doi.org/10.1016/j.ultramic.2014.03.008
Abstract: The conventional approach to object reconstruction through electron tomography is to reduce the three-dimensional problem to a series of independent two-dimensional slice-by-slice reconstructions. However, at atomic resolution the image of a single atom extends over many such slices and incorporating this image as prior knowledge in tomography or depth sectioning therefore requires a fully three-dimensional treatment. Unfortunately, the size of the three-dimensional projection operator scales highly unfavorably with object size and readily exceeds the available computer memory. In this paper, it is shown that for incoherent image formation the memory requirement can be reduced to the fundamental lower limit of the object size, both for tomography and depth sectioning. Furthermore, it is shown through multislice calculations that high angle annular dark field scanning transmission electron microscopy can be sufficiently incoherent for the reconstruction of single element nanocrystals, but that dynamical diffraction effects can cause classification problems if more than one element is present. (C) 2014 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 6
DOI: 10.1016/j.ultramic.2014.03.008
|
|
|
“An alternative approach to determine attainable resolution directly from HREM images”. Wang A, Turner S, Van Aert S, van Dyck D, Ultramicroscopy 133, 50 (2013). http://doi.org/10.1016/j.ultramic.2013.05.008
Abstract: The concept of resolution in high-resolution electron microscopy (HREM) is the power to resolve neighboring atoms. Since the resolution is related to the width of the point spread function of the microscope, it could in principle be determined from the image of a point object. However, in electron microscopy there are no ideal point objects. The smallest object is an individual atom. If the width of an atom is much smaller than the resolution of the microscope, this atom can still be considered as a point object. As the resolution of the microscope enters the sub-Å regime, information about the microscope is strongly entangled with the information about the atoms in HREM images. Therefore, we need to find an alternative method to determine the resolution in an object-independent way. In this work we propose to use the image wave of a crystalline object in zone axis orientation. Under this condition, the atoms of a column act as small lenses so that the electron beam channels through the atom column periodically. Because of this focusing, the image wave of the column can be much more peaked than the constituting atoms and can thus be a much more sensitive probe to measure the resolution. Our approach is to use the peakiness of the image wave of the atom column to determine the resolution. We will show that the resolution can be directly linked to the total curvature of the atom column wave. Moreover, we can then directly obtain the resolution of the microscope given that the contribution from the object is known, which is related to the bounding energy of the atom. The method is applied on an experimental CaTiO3 image wave.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
DOI: 10.1016/j.ultramic.2013.05.008
|
|
|
“High precision measurements of atom column positions using model-based exit wave reconstruction”. de Backer A, Van Aert S, van Dyck D, Ultramicroscopy 111, 1475 (2011). http://doi.org/10.1016/j.ultramic.2011.07.002
Abstract: In this paper, it has been investigated how to measure atom column positions as accurately and precisely as possible using a focal series of images. In theory, it is expected that the precision would considerably improve using a maximum likelihood estimator based on the full series of focal images. As such, the theoretical lower bound on the variances of the unknown atom column positions can be attained. However, this approach is numerically demanding. Therefore, maximum likelihood estimation has been compared with the results obtained by fitting a model to a reconstructed exit wave rather than to the full series of focal images. Hence, a real space model-based exit wave reconstruction technique based on the channelling theory is introduced. Simulations show that the reconstructed complex exit wave contains the same amount of information concerning the atom column positions as the full series of focal images. Only for thin samples, which act as weak phase objects, this information can be retrieved from the phase of the reconstructed complex exit wave.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 8
DOI: 10.1016/j.ultramic.2011.07.002
|
|
|
“Artifact Reduction Based on Sinogram Interpolation for the 3D Reconstruction of Nanoparticles Using Electron Tomography”. Sentosun K, Lobato I, Bladt E, Zhang Y, Palenstijn WJ, Batenburg KJ, Van Dyck D, Bals S, Particle and particle systems characterization 34, 1700287 (2017). http://doi.org/10.1002/ppsc.201700287
Abstract: Electron tomography is a well-known technique providing a 3D characterization of the morphology and chemical composition of nanoparticles. However, several reasons hamper the acquisition of tilt series with a large number of projection images, which deteriorate the quality of the 3D reconstruction. Here, an inpainting method that is based on sinogram interpolation is proposed, which enables one to reduce artifacts in the reconstruction related to a limited tilt series of projection images. The advantages of the approach will be demonstrated for the 3D characterization of nanoparticles using phantoms and several case studies.
Keywords: A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT); Vision lab
Times cited: 2
DOI: 10.1002/ppsc.201700287
|
|
|
“Advanced electron microscopy for advanced materials”. Van Tendeloo G, Bals S, Van Aert S, Verbeeck J, van Dyck D, Advanced materials 24, 5655 (2012). http://doi.org/10.1002/adma.201202107
Abstract: The idea of this Review is to introduce newly developed possibilities of advanced electron microscopy to the materials science community. Over the last decade, electron microscopy has evolved into a full analytical tool, able to provide atomic scale information on the position, nature, and even the valency atoms. This information is classically obtained in two dimensions (2D), but can now also be obtained in 3D. We show examples of applications in the field of nanoparticles and interfaces.
Keywords: A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 19.791
Times cited: 107
DOI: 10.1002/adma.201202107
|
|
|
“MULTEM : a new multislice program to perform accurate and fast electron diffraction and imaging simulations using graphics processing units with CUDA”. Lobato I, Van Dyck D, Ultramicroscopy 156, 9 (2015). http://doi.org/10.1016/j.ultramic.2015.04.016
Abstract: The main features and the GPU implementation of the MULTEM program are presented and described. This new program performs accurate and fast multislice simulations by including higher order expansion of the multislice solution of the high energy Schrodinger equation, the correct subslicing of the three-dimensional potential and top-bottom surfaces. The program implements different kinds of simulation for CTEM, STEM, ED, PED, CBED, ADF-TEM and ABF-HC with proper treatment of the spatial and temporal incoherences. The multislice approach described here treats the specimen as amorphous material which allows a straightforward implementation of the frozen phonon approximation. The generalized transmission function for each slice is calculated when is needed and then discarded. This allows us to perform large simulations that can include millions of atoms and keep the computer memory requirements to a reasonable level. (C) 2015 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 32
DOI: 10.1016/j.ultramic.2015.04.016
|
|
|
“Correction of non-linear thickness effects in HAADF STEM electron tomography”. van den Broek W, Rosenauer A, Goris B, Martinez GT, Bals S, Van Aert S, van Dyck D, Ultramicroscopy 116, 8 (2012). http://doi.org/10.1016/j.ultramic.2012.03.005
Abstract: In materials science, high angle annular dark field scanning transmission electron microscopy is often used for tomography at the nanometer scale. In this work, it is shown that a thickness dependent, non-linear damping of the recorded intensities occurs. This results in an underestimated intensity in the interior of reconstructions of homogeneous particles, which is known as the cupping artifact. In this paper, this non-linear effect is demonstrated in experimental images taken under common conditions and is reproduced with a numerical simulation. Furthermore, an analytical derivation shows that these non-linearities can be inverted if the imaging is done quantitatively, thus preventing cupping in the reconstruction.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 67
DOI: 10.1016/j.ultramic.2012.03.005
|
|
|
“Statistical estimation of oxygen atomic positions eith sub Ångstrom precision from exit wave reconstruction”. Bals S, Van Aert S, Van Tendeloo G, van Dyck D, Avila-Brande D, Microscopy and microanalysis 11, 556 (2005)
Keywords: A3 Journal article; Electron microscopy for materials research (EMAT); Vision lab
|
|
|
“Atomic resolution electron tomography: a dream?”.van Dyck D, Van Aert S, Croitoru M, International journal of materials research 97, 872 (2006). http://doi.org/10.3139/146.101314
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Condensed Matter Theory (CMT); Vision lab
Impact Factor: 0.681
Times cited: 6
DOI: 10.3139/146.101314
|
|
|
“High-resolution electron microscopy : from imaging toward measuring”. Van Aert S, den Dekker AJ, van den Bos A, van Dyck D, IEEE transactions on instrumentation and measurement 51, 611 (2002). http://doi.org/10.1109/TIM.2002.802250
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.456
Times cited: 13
DOI: 10.1109/TIM.2002.802250
|
|
|
“High resolution electron microscopy from imaging towards measuring”. Van Aert S, den Dekker AJ, van den Bos A, Van Dyck D ... IEEE International Instrumentation and Measurement Technology Conference
T2 – Rediscovering measurement in the age of informatics : proceedings of the 18th IEEE Instrumentation and Measurement Technology Conference (IMTC), 2001: vol 3. Ieee, page 2081 (2001).
Keywords: H2 Book chapter; Electron microscopy for materials research (EMAT); Vision lab
DOI: 10.1109/IMTC.2001.929564
|
|
|
“Do smaller probes in a scanning transmission electron microscope result in more precise measurement of the distances between atom columns?”.Van Aert S, van Dyck D, Philosophical magazine: B: physics of condensed matter: electronic, optical and magnetic properties 81, 1833 (2001). http://doi.org/10.1080/13642810108223121
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Times cited: 11
DOI: 10.1080/13642810108223121
|
|
|
“Holotomography: quantitative phase tomography with micrometer resolution using hard synchrotron radiation X-rays”. Cloetens P, Ludwig W, Baruchel J, van Dyck D, van Landuyt J, Guigay JP, Schlenker M, Applied physics letters 75, 2912 (1999). http://doi.org/10.1063/1.125225
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 3.411
Times cited: 481
DOI: 10.1063/1.125225
|
|
|
“An electron microscopic study of highly oriented undoped and FeCl3-doped poly (p-phenylenevinylene)”. Zhang XB, Van Tendeloo G, van Landuyt J, van Dyck D, Briers J, Bao Y, Geise HJ, Macromolecules 29, 1554 (1996). http://doi.org/10.1021/ma9513067
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 5.8
Times cited: 10
DOI: 10.1021/ma9513067
|
|
|
“Fully automated measurement of the modulation transfer function of charge-coupled devices above the Nyquist frequency”. van den Broek W, Van Aert S, van Dyck D, Microscopy and microanalysis 18, 336 (2012). http://doi.org/10.1017/S1431927611012633
Abstract: The charge-coupled devices used in electron microscopy are coated with a scintillating crystal that gives rise to a severe modulation transfer function (MTF). Exact knowledge of the MTF is imperative for a good correspondence between image simulation and experiment. We present a practical method to measure the MTF above the Nyquist frequency from the beam blocker's shadow image. The image processing has been fully automated and the program is made public. The method is successfully tested on three cameras with various beam blocker shapes.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 1.891
Times cited: 15
DOI: 10.1017/S1431927611012633
|
|
|
“Physical limits on atomic resolution”. van Dyck D, Van Aert S, den Dekker AJ, Microscopy and microanalysis 10, 153 (2004). http://doi.org/10.1017/S143192760404036X
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 1.891
Times cited: 14
DOI: 10.1017/S143192760404036X
|
|
|
“Statistical experimental design for quantitative atomic resolution transmission electron microscopy”. Van Aert S, den Dekker AJ, van den Bos A, van Dyck D Academic Press, San Diego, Calif., page 1 (2004).
Keywords: H1 Book chapter; Electron microscopy for materials research (EMAT); Vision lab
Times cited: 13
DOI: 10.1016/S1076-5670(04)30001-7
|
|
|
“High-resolution electron microscopy and electron tomography: resolution versus precision”. Van Aert S, den Dekker AJ, van Dyck D, van den Bos A, Journal of structural biology 138, 21 (2002). http://doi.org/10.1016/S1047-8477(02)00016-3
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.767
Times cited: 33
DOI: 10.1016/S1047-8477(02)00016-3
|
|
|
“Structural characterization of Nb-TiO2 nanosized thick-films for gas sensing application”. Ferroni M, Carotta MC, Guidi V, Martinelli G, Ronconi F, Richard O, van Dyck D, van Landuyt J, Sensors and actuators : B : chemical 68, 140 (2000). http://doi.org/10.1016/S0925-4005(00)00474-3
Abstract: Pure and Nb-doped TiO2 thick-films were prepared by screen-printing, starting from nanosized powders. Grain growth and crystalline phase modification occurred as consequence of firing at high temperature. It has been shown that niobium addition inhibits grain coarsening and hinders anatase-to-rutile phase transition. These semiconducting films exhibited n-type behavior, while Nb acted as donor-dopant. Gas measurements demonstrated that the films are suitable for CO or NO2 sensing. Microstructural characterization by electron microscopy and differential thermal analysis (DTA) highlights the dependence of gas-sensing behavior on film's properties. (C) 2000 Elsevier Science S.A. All rights reserved.
Keywords: P1 Proceeding; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 5.401
Times cited: 51
DOI: 10.1016/S0925-4005(00)00474-3
|
|
|
“Is atomic resolution transmission electron microscopy able to resolve and refine amorphous structures?”.van Dyck D, Van Aert S, den Dekker AJ, van den Bos A, Ultramicroscopy 98, 27 (2003). http://doi.org/10.1016/S0304-3991(03)00023-8
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 26
DOI: 10.1016/S0304-3991(03)00023-8
|
|
|
“Optimal experimental design of STEM measurement of atom column positions”. Van Aert S, den Dekker AJ, van Dyck D, van den Bos A, Ultramicroscopy 90, 273 (2002). http://doi.org/10.1016/S0304-3991(01)00152-8
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 35
DOI: 10.1016/S0304-3991(01)00152-8
|
|