|
Records |
Links |
|
Author |
Batenburg, J.; Van Aert, S. |
|
|
Title |
Three-dimensional reconstruction of a nanoparticle at atomic resolution |
Type |
A2 Journal article |
|
Year |
2011 |
Publication |
ERCIM news |
Abbreviated Journal |
|
|
|
Volume |
86 |
Issue |
|
Pages |
52 |
|
|
Keywords |
A2 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Le Chesnay |
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
0000-00-00 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0926-4981 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ lucian @ c:irua:94120 |
Serial |
3655 |
|
Permanent link to this record |
|
|
|
|
Author |
Wang, A.; Turner, S.; Van Aert, S.; van Dyck, D. |
|
|
Title |
An alternative approach to determine attainable resolution directly from HREM images |
Type |
A1 Journal article |
|
Year |
2013 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
|
|
Volume |
133 |
Issue |
|
Pages |
50-61 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
The concept of resolution in high-resolution electron microscopy (HREM) is the power to resolve neighboring atoms. Since the resolution is related to the width of the point spread function of the microscope, it could in principle be determined from the image of a point object. However, in electron microscopy there are no ideal point objects. The smallest object is an individual atom. If the width of an atom is much smaller than the resolution of the microscope, this atom can still be considered as a point object. As the resolution of the microscope enters the sub-Å regime, information about the microscope is strongly entangled with the information about the atoms in HREM images. Therefore, we need to find an alternative method to determine the resolution in an object-independent way. In this work we propose to use the image wave of a crystalline object in zone axis orientation. Under this condition, the atoms of a column act as small lenses so that the electron beam channels through the atom column periodically. Because of this focusing, the image wave of the column can be much more peaked than the constituting atoms and can thus be a much more sensitive probe to measure the resolution. Our approach is to use the peakiness of the image wave of the atom column to determine the resolution. We will show that the resolution can be directly linked to the total curvature of the atom column wave. Moreover, we can then directly obtain the resolution of the microscope given that the contribution from the object is known, which is related to the bounding energy of the atom. The method is applied on an experimental CaTiO3 image wave. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
|
|
Language |
|
Wos |
000324471800007 |
Publication Date |
2013-05-23 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record |
|
|
Impact Factor |
2.843 |
Times cited |
|
Open Access |
|
|
|
Notes |
FWO; Hercules; Esteem2; esteem2_jra2 |
Approved |
Most recent IF: 2.843; 2013 IF: 2.745 |
|
|
Call Number |
UA @ lucian @ c:irua:109919 |
Serial |
90 |
|
Permanent link to this record |
|
|
|
|
Author |
de Backer, A.; De wael, A.; Gonnissen, J.; Van Aert, S. |
|
|
Title |
Optimal experimental design for nano-particle atom-counting from high-resolution STEM images |
Type |
A1 Journal article |
|
Year |
2015 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
|
|
Volume |
151 |
Issue |
151 |
Pages |
46-55 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
In the present paper, the principles of detection theory are used to quantify the probability of error for atom-counting from high resolution scanning transmission electron microscopy (HR STEM) images. Binary and multiple hypothesis testing have been investigated in order to determine the limits to the precision with which the number of atoms in a projected atomic column can be estimated. The probability of error has been calculated when using STEM images, scattering cross-sections or peak intensities as a criterion to count atoms. Based on this analysis, we conclude that scattering cross-sections perform almost equally well as images and perform better than peak intensities. Furthermore, the optimal STEM detector design can be derived for atom-counting using the expression for the probability of error. We show that for very thin objects LAADF is optimal and that for thicker objects the optimal inner detector angle increases. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
|
|
Language |
|
Wos |
000351237800007 |
Publication Date |
2014-11-11 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.843 |
Times cited |
24 |
Open Access |
|
|
|
Notes |
312483 Esteem2; Fwo G039311; G037413; esteem2_jra2 |
Approved |
Most recent IF: 2.843; 2015 IF: 2.436 |
|
|
Call Number |
c:irua:123926 c:irua:123926 |
Serial |
2481 |
|
Permanent link to this record |
|
|
|
|
Author |
Martinez, G.T.; Jones, L.; de Backer, A.; Béché, A.; Verbeeck, J.; Van Aert, S.; Nellist, P.D. |
|
|
Title |
Quantitative STEM normalisation : the importance of the electron flux |
Type |
A1 Journal article |
|
Year |
2015 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
|
|
Volume |
159 |
Issue |
159 |
Pages |
46-58 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
Annular dark-field (ADF) scanning transmission electron microscopy (STEM) has become widely used in quantitative studies based on the opportunity to directly compare experimental and simulated images. This comparison merely requires the experimental data to be normalised and expressed in units of fractional beam-current. However, inhomogeneities in the response of electron detectors can complicate this normalisation. The quantification procedure becomes both experiment and instrument specific, requiring new simulations for the particular response of each instrument's detector, and for every camera-length used. This not only impedes the comparison between different instruments and research groups, but can also be computationally very time consuming. Furthermore, not all image simulation methods allow for the inclusion of an inhomogeneous detector response. In this work, we propose an alternative method for normalising experimental data in order to compare these with simulations that consider a homogeneous detector response. To achieve this, we determine the electron flux distribution reaching the detector by means of a camera-length series or a so-called atomic column cross-section averaged convergent beam electron diffraction (XSACBED) pattern. The result is then used to determine the relative weighting of the detector response. Here we show that the results obtained by this new electron flux weighted (EFW) method are comparable to the currently used method, while considerably simplifying the needed simulation libraries. The proposed method also allows one to obtain a metric that describes the quality of the detector response in comparison with the ideal detector response. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
|
|
Language |
|
Wos |
000366220000006 |
Publication Date |
2015-08-01 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.843 |
Times cited |
27 |
Open Access |
|
|
|
Notes |
246791 Countatoms; 278510 Vortex; 312483 Esteem2; Fwo G036815; G036915; G037413; G004413; esteem2ta ECASJO; |
Approved |
Most recent IF: 2.843; 2015 IF: 2.436 |
|
|
Call Number |
c:irua:127293 c:irua:127293UA @ admin @ c:irua:127293 |
Serial |
2762 |
|
Permanent link to this record |
|
|
|
|
Author |
Alania, M.; Altantzis, T.; De Backer, A.; Lobato, I.; Bals, S.; Van Aert, S. |
|
|
Title |
Depth sectioning combined with atom-counting in HAADF STEM to retrieve the 3D atomic structure |
Type |
A1 Journal article |
|
Year |
2016 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
|
|
Volume |
177 |
Issue |
177 |
Pages |
36-42 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
Aberration correction in scanning transmission electron microscopy (STEM) has greatly improved the lateral and depth resolution. When using depth sectioning, a technique during which a series of images is recorded at different defocus values, single impurity atoms can be visualised in three dimensions. In this paper, we investigate new possibilities emerging when combining depth sectioning and precise atom-counting in order to reconstruct nanosized particles in three dimensions. Although the depth resolution does not allow one to precisely locate each atom within an atomic column, it will be shown that the depth location of an atomic column as a whole can be measured precisely. In this manner, the morphology of a nanoparticle can be reconstructed in three dimensions. This will be demonstrated using simulations and experimental data of a gold nanorod. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000401219800006 |
Publication Date |
2016-11-09 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0304-3991 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.843 |
Times cited |
13 |
Open Access |
OpenAccess |
|
|
Notes |
The authors acknowledge financial support from the European Union under the Seventh Framework Program under a contract for an Integrated Infrastructure Initiative. Reference No. 312483-ESTEEM2. S. Bals acknowledges funding from the European Research Council (Starting Grant No. COLOURATOMS 335078). The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through project fundings (G.0374.13N, G.0369.15N and G.0368.15N) and a post-doctoral grant to A. De Backer and T. Altantzis. The authors are grateful to Professor Luis M. Liz-Marzán for providing the sample.; ECAS_Sara; (ROMEO:green; preprint:; postprint:can ; pdfversion:cannot); |
Approved |
Most recent IF: 2.843 |
|
|
Call Number |
EMAT @ emat @ c:irua:138015UA @ admin @ c:irua:138015 |
Serial |
4316 |
|
Permanent link to this record |
|
|
|
|
Author |
den Dekker, A.J.; Gonnissen, J.; de Backer, A.; Sijbers, J.; Van Aert, S. |
|
|
Title |
Estimation of unknown structure parameters from high-resolution (S)TEM images : what are the limits? |
Type |
A1 Journal article |
|
Year |
2013 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
|
|
Volume |
134 |
Issue |
|
Pages |
34-43 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
Statistical parameter estimation theory is proposed as a quantitative method to measure unknown structure parameters from electron microscopy images. Images are then purely considered as data planes from which structure parameters have to be determined as accurately and precisely as possible using a parametric statistical model of the observations. For this purpose, an efficient algorithm is proposed for the estimation of atomic column positions and intensities from high angle annular dark field (HAADF) scanning transmission electron microscopy (STEM) images. Furthermore, the so-called CramérRao lower bound (CRLB) is reviewed to determine the limits to the precision with which continuous parameters such as atomic column positions and intensities can be estimated. Since this lower bound can only be derived for continuous parameters, alternative measures using the principles of detection theory are introduced for problems concerning the estimation of discrete parameters such as atomic numbers. An experimental case study is presented to show the practical use of these measures for the optimization of the experiment design if the purpose is to decide between the presence of specific atom types using STEM images. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
|
|
Language |
|
Wos |
000324474900006 |
Publication Date |
2013-06-01 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.843 |
Times cited |
31 |
Open Access |
|
|
|
Notes |
FWO; FP 2007-2013; Esteem2; esteem2_jra2 |
Approved |
Most recent IF: 2.843; 2013 IF: 2.745 |
|
|
Call Number |
UA @ lucian @ c:irua:109240 |
Serial |
1083 |
|
Permanent link to this record |
|
|
|
|
Author |
de Backer, A.; Fatermans, J.; den Dekker, A.J.; Van Aert, S. |
|
|
Title |
Statistical parameter estimation theory : principles and simulation studies |
Type |
H2 Book chapter |
|
Year |
2021 |
Publication |
Advances in imaging and electron physics
T2 – Advances in imaging and electron physics |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
29-72 |
|
|
Keywords |
H2 Book chapter; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
In this chapter, the principles of statistical parameter estimation theory for a quantitative analysis of atomic-resolution electron microscopy images are introduced. Within this framework, electron microscopy images are described by a parametric statistical model. Here, parametric models are introduced for different types of electron microscopy images: reconstructed exit waves, annular dark-field (ADF) scanning transmission electron microscopy (STEM) images, and simultaneously acquired ADF and annular bright-field (ABF) STEM images. Furthermore, the Cramér-Rao lower bound (CRLB) is introduced, i.e. a theoretical lower bound on the variance of any unbiased estimator. This CRLB is used to quantify the precision of the structure parameters of interest, such as the atomic column positions and the integrated atomic column intensities. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2021-03-06 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
217 |
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
978-0-12-824607-8; 1076-5670 |
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
Not_Open_Access |
|
|
Notes |
ERC Consolidator project funded by the European Union grant #770887 Picometrics |
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ admin @ c:irua:177527 |
Serial |
6788 |
|
Permanent link to this record |
|
|
|
|
Author |
van Dyck, D.; Van Aert, S.; den Dekker, A.J.; van den Bos, A. |
|
|
Title |
Is atomic resolution transmission electron microscopy able to resolve and refine amorphous structures? |
Type |
A1 Journal article |
|
Year |
2003 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
|
|
Volume |
98 |
Issue |
|
Pages |
27-42 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
|
|
Language |
|
Wos |
000186831500003 |
Publication Date |
2003-04-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.843 |
Times cited |
26 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 2.843; 2003 IF: 1.665 |
|
|
Call Number |
UA @ lucian @ c:irua:47516 |
Serial |
1749 |
|
Permanent link to this record |
|
|
|
|
Author |
de Backer, A.; Martinez, G.T.; Rosenauer, A.; Van Aert, S. |
|
|
Title |
Atom counting in HAADF STEM using a statistical model-based approach : methodology, possibilities, and inherent limitations |
Type |
A1 Journal article |
|
Year |
2013 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
|
|
Volume |
134 |
Issue |
|
Pages |
23-33 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
In the present paper, a statistical model-based method to count the number of atoms of monotype crystalline nanostructures from high resolution high-angle annular dark-field (HAADF) scanning transmission electron microscopy (STEM) images is discussed in detail together with a thorough study on the possibilities and inherent limitations. In order to count the number of atoms, it is assumed that the total scattered intensity scales with the number of atoms per atom column. These intensities are quantitatively determined using model-based statistical parameter estimation theory. The distribution describing the probability that intensity values are generated by atomic columns containing a specific number of atoms is inferred on the basis of the experimental scattered intensities. Finally, the number of atoms per atom column is quantified using this estimated probability distribution. The number of atom columns available in the observed STEM image, the number of components in the estimated probability distribution, the width of the components of the probability distribution, and the typical shape of a criterion to assess the number of components in the probability distribution directly affect the accuracy and precision with which the number of atoms in a particular atom column can be estimated. It is shown that single atom sensitivity is feasible taking the latter aspects into consideration. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
|
|
Language |
|
Wos |
000324474900005 |
Publication Date |
2013-05-17 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.843 |
Times cited |
48 |
Open Access |
|
|
|
Notes |
FWO; Esteem2; FP 2007-2013; esteem2_jra2 |
Approved |
Most recent IF: 2.843; 2013 IF: 2.745 |
|
|
Call Number |
UA @ lucian @ c:irua:109916 |
Serial |
162 |
|
Permanent link to this record |
|
|
|
|
Author |
Van den Broek, W.; Rosenauer, A.; Van Aert, S.; Sijbers, J.; van Dyck, D. |
|
|
Title |
A memory efficient method for fully three-dimensional object reconstruction with HAADF STEM |
Type |
A1 Journal article |
|
Year |
2014 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
|
|
Volume |
141 |
Issue |
|
Pages |
22-31 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
The conventional approach to object reconstruction through electron tomography is to reduce the three-dimensional problem to a series of independent two-dimensional slice-by-slice reconstructions. However, at atomic resolution the image of a single atom extends over many such slices and incorporating this image as prior knowledge in tomography or depth sectioning therefore requires a fully three-dimensional treatment. Unfortunately, the size of the three-dimensional projection operator scales highly unfavorably with object size and readily exceeds the available computer memory. In this paper, it is shown that for incoherent image formation the memory requirement can be reduced to the fundamental lower limit of the object size, both for tomography and depth sectioning. Furthermore, it is shown through multislice calculations that high angle annular dark field scanning transmission electron microscopy can be sufficiently incoherent for the reconstruction of single element nanocrystals, but that dynamical diffraction effects can cause classification problems if more than one element is present. (C) 2014 Elsevier B.V. All rights reserved. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
|
|
Language |
|
Wos |
000335766600004 |
Publication Date |
2014-03-22 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.843 |
Times cited |
6 |
Open Access |
|
|
|
Notes |
ResearchFoundationFlanders(FWO;G.0393.11; G.0064.10;andG.0374.13); European Union Seventh Frame- workProgramme [FP7/2007-2013]under Grant agreement no. 312483 (ESTEEM2).; esteem2jra2; esteem2jra4 |
Approved |
Most recent IF: 2.843; 2014 IF: 2.436 |
|
|
Call Number |
UA @ lucian @ c:irua:117650 |
Serial |
1992 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Aert, S.; den Dekker, A.J.; van Dyck, D.; van den Bos, A. |
|
|
Title |
High-resolution electron microscopy and electron tomography: resolution versus precision |
Type |
A1 Journal article |
|
Year |
2002 |
Publication |
Journal of structural biology |
Abbreviated Journal |
J Struct Biol |
|
|
Volume |
138 |
Issue |
|
Pages |
21-33 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
New York |
Editor |
|
|
|
Language |
|
Wos |
000177978800003 |
Publication Date |
2002-09-17 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1047-8477; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.767 |
Times cited |
33 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 2.767; 2002 IF: 4.194 |
|
|
Call Number |
UA @ lucian @ c:irua:47520 |
Serial |
1446 |
|
Permanent link to this record |
|
|
|
|
Author |
Wang, A.; Van Aert, S.; Goos, P.; van Dyck, D. |
|
|
Title |
Precision of three-dimensional atomic scale measurements from HRTEM images : what are the limits? |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
|
|
Volume |
114 |
Issue |
|
Pages |
20-30 |
|
|
Keywords |
A1 Journal article; Engineering Management (ENM); Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
In this paper, we investigate to what extent high resolution transmission electron microscopy images can be used to measure the mass, in terms of thickness, and surface profile, corresponding to the defocus offset, of an object at the atomic scale. Therefore, we derive an expression for the statistical precision with which these object parameters can be estimated in a quantitative analysis. Evaluating this expression as a function of the microscope settings allows us to derive the optimal microscope design. Acquiring three-dimensional structure information in terms of thickness turns out to be much more difficult than obtaining two-dimensional information on the projected atom column positions. The attainable precision is found to be more strongly affected by processes influencing the image contrast, such as phonon scattering, than by the specific choice of microscope settings. For a realistic incident electron dose, it is expected that atom columns can be distinguished with single atom sensitivity up to a thickness of the order of the extinction distance. A comparable thickness limit is determined to measure surface steps of one atom. An increase of the electron dose shifts the limiting thickness upward due to an increase in the signal-to-noise ratio. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
|
|
Language |
|
Wos |
000301954300003 |
Publication Date |
2012-01-06 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.843 |
Times cited |
5 |
Open Access |
|
|
|
Notes |
Fwo |
Approved |
Most recent IF: 2.843; 2012 IF: 2.470 |
|
|
Call Number |
UA @ lucian @ c:irua:94116 |
Serial |
2692 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Aert, S. |
|
|
Title |
Meer zien met onzichtbaar licht |
Type |
A2 Journal article |
|
Year |
2007 |
Publication |
Karakter : tijdschrift van wetenschap |
Abbreviated Journal |
|
|
|
Volume |
18 |
Issue |
|
Pages |
19-21 |
|
|
Keywords |
A2 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Leuven |
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
0000-00-00 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1379-0390 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ lucian @ c:irua:68658 |
Serial |
1982 |
|
Permanent link to this record |
|
|
|
|
Author |
Rosenauer, A.; Gerthsen, D.; Van Aert, S.; van Dyck, D.; den Dekker, A.J. |
|
|
Title |
Present state of the composition evaluation of ternary semiconductor nanostructures by lattice fringe analysis |
Type |
A1 Journal article |
|
Year |
2003 |
Publication |
Institute of physics conference series |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
180 |
Pages |
19-22 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
Semiconductor heterostructures are used for the fabrication of optoelectronic devices. Performance of such devices is governed by their chemical morphology. The composition distribution of quantum wells and dots is influenced by kinetic growth processes which are not understood completely at present. To obtain more information about these effects, methods for composition determination with a spatial resolution at a near atomic scale are necessary. In this paper we focus on the present state of the composition evaluation by the lattice fringe analysis (CELFA) technique and explain the basic ideas, optimum imaging conditions, precision and accuracy. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
0000-00-00 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0-7503-0979-2 |
ISBN |
|
Additional Links |
UA library record; WoS full record; |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ lucian @ c:irua:95118 |
Serial |
2710 |
|
Permanent link to this record |
|
|
|
|
Author |
Lobato, I.; Van Aert, S.; Verbeeck, J. |
|
|
Title |
Progress and new advances in simulating electron microscopy datasets using MULTEM |
Type |
A1 Journal article |
|
Year |
2016 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
|
|
Volume |
168 |
Issue |
168 |
Pages |
17-27 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
A new version of the open source program MULTEM is presented here. It includes a graphical user interface, tapering truncation of the atomic potential, CPU multithreading functionality, single/double precision calculations, scanning transmission electron microscopy (STEM) simulations using experimental detector sensitivities, imaging STEM (ISTEM) simulations, energy filtered transmission electron microscopy (EFTEM) simulations, STEM electron energy loss spectroscopy (EELS) simulations along with other improvements in the algorithms. We also present a mixed channeling approach for the calculation of inelastic excitations, which allows one to considerably speed up time consuming EFTEM/STEM-EELS calculations. |
|
|
Address |
EMAT, University of Antwerp, Department of Physics, Groenenborgerlaan 171, B-2020 Antwerp, Belgium |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Wos |
000380754100003 |
Publication Date |
2016-06-11 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0304-3991 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.843 |
Times cited |
43 |
Open Access |
|
|
|
Notes |
The authors acknowledge financial support from the European Union under the Seventh Framework Program under a contract for an Integrated Infrastructure Initiative. Reference No. 312483- ESTEEM2. The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through project fundings (G.0374.13N, G.0369.15N and G.0368.15N).; esteem2jra3; esteem2na3; esteem2_jra2 |
Approved |
Most recent IF: 2.843 |
|
|
Call Number |
c:irua:134088 c:irua:134088UA @ admin @ c:irua:134088 |
Serial |
4093 |
|
Permanent link to this record |
|
|
|
|
Author |
Schryvers, D.; Van Aert, S.; Delville, R.; Idrissi, H.; Turner, S.; Salje, E.K.H. |
|
|
Title |
Dedicated TEM on domain boundaries from phase transformations and crystal growth |
Type |
A1 Journal article |
|
Year |
2013 |
Publication |
Phase transitions |
Abbreviated Journal |
Phase Transit |
|
|
Volume |
86 |
Issue |
1 |
Pages |
15-22 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
Investigating domain boundaries and their effects on the behaviour of materials automatically implies the need for detailed knowledge on the structural aspects of the atomic configurations at these interfaces. Not only in view of nearest neighbour interactions but also at a larger scale, often surpassing the unit cell, the boundaries can contain structural elements that do not exist in the bulk. In the present contribution, a number of special boundaries resulting from phase transformations or crystal growth and those recently investigated by advanced transmission electron microscopy techniques in different systems will be reviewed. These include macrotwins between microtwinned martensite plates in NiAl, austenite-single variant martensite habit planes in low hysteresis NiTiPd, nanotwins in non-textured nanostructured Pd and ferroelastic domain boundaries in CaTiO3. In all discussed cases these boundaries play an essential role in the properties of the respective materials. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
New York |
Editor |
|
|
|
Language |
|
Wos |
000312586700003 |
Publication Date |
2012-12-19 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0141-1594;1029-0338; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.06 |
Times cited |
|
Open Access |
|
|
|
Notes |
Fwo; Iap |
Approved |
Most recent IF: 1.06; 2013 IF: 1.044 |
|
|
Call Number |
UA @ lucian @ c:irua:101222 |
Serial |
612 |
|
Permanent link to this record |
|
|
|
|
Author |
Martinez, G.T.; Rosenauer, A.; de Backer, A.; Verbeeck, J.; Van Aert, S. |
|
|
Title |
Quantitative composition determination at the atomic level using model-based high-angle annular dark field scanning transmission electron microscopy |
Type |
A1 Journal article |
|
Year |
2014 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
|
|
Volume |
137 |
Issue |
|
Pages |
12-19 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
High angle annular dark field scanning transmission electron microscopy (HAADF STEM) images provide sample information which is sensitive to the chemical composition. The image intensities indeed scale with the mean atomic number Z. To some extent, chemically different atomic column types can therefore be visually distinguished. However, in order to quantify the atomic column composition with high accuracy and precision, model-based methods are necessary. Therefore, an empirical incoherent parametric imaging model can be used of which the unknown parameters are determined using statistical parameter estimation theory (Van Aert et al., 2009, [1]). In this paper, it will be shown how this method can be combined with frozen lattice multislice simulations in order to evolve from a relative toward an absolute quantification of the composition of single atomic columns with mixed atom types. Furthermore, the validity of the model assumptions are explored and discussed. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
|
|
Language |
|
Wos |
000331092200003 |
Publication Date |
2013-11-09 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.843 |
Times cited |
74 |
Open Access |
|
|
|
Notes |
FWO; FP7; ERC Countatoms; ESTEEM2; esteem2_ta |
Approved |
Most recent IF: 2.843; 2014 IF: 2.436 |
|
|
Call Number |
UA @ lucian @ c:irua:111579UA @ admin @ c:irua:111579 |
Serial |
2749 |
|
Permanent link to this record |
|
|
|
|
Author |
Goris, B.; De Beenhouwer, J.; de Backer, A.; Zanaga, D.; Batenburg, J.; Sanchez-Iglesias, A.; Liz-Marzan, L.; Van Aert, S.; Sijbers, J.; Van Tendeloo, G.; Bals, S. |
|
|
Title |
Investigating lattice strain in Au nanodecahedrons |
Type |
P1 Proceeding |
|
Year |
2016 |
Publication |
|
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
11-12 |
|
|
Keywords |
P1 Proceeding; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2016-12-21 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
978-3-527-80846-5 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
Not_Open_Access |
|
|
Notes |
|
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ lucian @ c:irua:145813 |
Serial |
5144 |
|
Permanent link to this record |
|
|
|
|
Author |
Lobato, I.; Friedrich, T.; Van Aert, S. |
|
|
Title |
Deep convolutional neural networks to restore single-shot electron microscopy images |
Type |
A1 Journal article |
|
Year |
2024 |
Publication |
N P J Computational Materials |
Abbreviated Journal |
npj Comput Mater |
|
|
Volume |
10 |
Issue |
1 |
Pages |
10 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
Advanced electron microscopy techniques, including scanning electron microscopes (SEM), scanning transmission electron microscopes (STEM), and transmission electron microscopes (TEM), have revolutionized imaging capabilities. However, achieving high-quality experimental images remains a challenge due to various distortions stemming from the instrumentation and external factors. These distortions, introduced at different stages of imaging, hinder the extraction of reliable quantitative insights. In this paper, we will discuss the main sources of distortion in TEM and S(T)EM images, develop models to describe them, and propose a method to correct these distortions using a convolutional neural network. We validate the effectiveness of our method on a range of simulated and experimental images, demonstrating its ability to significantly enhance the signal-to-noise ratio. This improvement leads to a more reliable extraction of quantitative structural information from the images. In summary, our findings offer a robust framework to enhance the quality of electron microscopy images, which in turn supports progress in structural analysis and quantification in materials science and biology. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
001138183000001 |
Publication Date |
2024-01-09 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2057-3960 |
ISBN |
|
Additional Links |
UA library record; WoS full record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
This work was supported by the European Research Council (Grant 770887 PICOMETRICS to S.V.A.). The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through project fundings (G034621N, G0A7723N and EOS 40007495). S.V.A. acknowledges funding from the University of Antwerp Research Fund (BOF). The authors thank Lukas Grünewald for data acquisition and support for Fig. 7. |
Approved |
Most recent IF: NA |
|
|
Call Number |
EMAT @ emat @c:irua:202714 |
Serial |
8994 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Aert, S. |
|
|
Title |
Atomen in 3D : Antwerpenaren brengen atomaire structuur nanodeeltjes in beeld |
Type |
Newspaper/Magazine/blog article |
|
Year |
2011 |
Publication |
Chemie magazine |
Abbreviated Journal |
|
|
|
Volume |
7 |
Issue |
3 |
Pages |
9 |
|
|
Keywords |
Newspaper/Magazine/blog article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
0000-00-00 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0379-7651 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ lucian @ c:irua:94122 |
Serial |
163 |
|
Permanent link to this record |
|
|
|
|
Author |
van den Broek, W.; Rosenauer, A.; Goris, B.; Martinez, G.T.; Bals, S.; Van Aert, S.; van Dyck, D. |
|
|
Title |
Correction of non-linear thickness effects in HAADF STEM electron tomography |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
|
|
Volume |
116 |
Issue |
|
Pages |
8-12 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
In materials science, high angle annular dark field scanning transmission electron microscopy is often used for tomography at the nanometer scale. In this work, it is shown that a thickness dependent, non-linear damping of the recorded intensities occurs. This results in an underestimated intensity in the interior of reconstructions of homogeneous particles, which is known as the cupping artifact. In this paper, this non-linear effect is demonstrated in experimental images taken under common conditions and is reproduced with a numerical simulation. Furthermore, an analytical derivation shows that these non-linearities can be inverted if the imaging is done quantitatively, thus preventing cupping in the reconstruction. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
|
|
Language |
|
Wos |
000304473700002 |
Publication Date |
2012-03-09 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.843 |
Times cited |
67 |
Open Access |
|
|
|
Notes |
Fwo |
Approved |
Most recent IF: 2.843; 2012 IF: 2.470 |
|
|
Call Number |
UA @ lucian @ c:irua:96558 |
Serial |
518 |
|
Permanent link to this record |
|
|
|
|
Author |
Jones, L.; Yang, H.; Pennycook, T.J.; Marshall, M.S.J.; Van Aert, S.; Browning, N.D.; Castell, M.R.; Nellist, P.D. |
|
|
Title |
Smart Align : a new tool for robust non-rigid registration of scanning microscope data |
Type |
A1 Journal article |
|
Year |
2015 |
Publication |
Advanced Structural and Chemical Imaging |
Abbreviated Journal |
|
|
|
Volume |
1 |
Issue |
1 |
Pages |
8 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
Many microscopic investigations of materials may benefit from the recording of multiple successive images. This can include techniques common to several types of microscopy such as frame averaging to improve signal-to-noise ratios (SNR) or time series to study dynamic processes or more specific applications. In the scanning transmission electron microscope, this might include focal series for optical sectioning or aberration measurement, beam damage studies or camera-length series to study the effects of strain; whilst in the scanning tunnelling microscope, this might include bias-voltage series to probe local electronic structure. Whatever the application, such investigations must begin with the careful alignment of these data stacks, an operation that is not always trivial. In addition, the presence of low-frequency scanning distortions can introduce intra-image shifts to the data. Here, we describe an improved automated method of performing non-rigid registration customised for the challenges unique to scanned microscope data specifically addressing the issues of low-SNR data, images containing a large proportion of crystalline material and/or local features of interest such as dislocations or edges. Careful attention has been paid to artefact testing of the non-rigid registration method used, and the importance of this registration for the quantitative interpretation of feature intensities and positions is evaluated. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000218507000008 |
Publication Date |
2015-07-09 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2198-0926; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
131 |
Open Access |
|
|
|
Notes |
312483 Esteem2; esteem2_jra2 |
Approved |
Most recent IF: NA |
|
|
Call Number |
c:irua:126944 c:irua:126944 |
Serial |
3043 |
|
Permanent link to this record |
|
|
|
|
Author |
Egoavil, R.; Gauquelin, N.; Martinez, G.T.; Van Aert, S.; Van Tendeloo, G.; Verbeeck, J. |
|
|
Title |
Atomic resolution mapping of phonon excitations in STEM-EELS experiments |
Type |
A1 Journal article |
|
Year |
2014 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
|
|
Volume |
147 |
Issue |
|
Pages |
1-7 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
Atomically resolved electron energy-loss spectroscopy experiments are commonplace in modern aberration-corrected transmission electron microscopes. Energy resolution has also been increasing steadily with the continuous improvement of electron monochromators. Electronic excitations however are known to be delocalized due to the long range interaction of the charged accelerated electrons with the electrons in a sample. This has made several scientists question the value of combined high spatial and energy resolution for mapping interband transitions and possibly phonon excitation in crystals. In this paper we demonstrate experimentally that atomic resolution information is indeed available at very low energy losses around 100 meV expressed as a modulation of the broadening of the zero loss peak. Careful data analysis allows us to get a glimpse of what are likely phonon excitations with both an energy loss and gain part. These experiments confirm recent theoretical predictions on the strong localization of phonon excitations as opposed to electronic excitations and show that a combination of atomic resolution and recent developments in increased energy resolution will offer great benefit for mapping phonon modes in real space. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
|
|
Language |
|
Wos |
000343157400001 |
Publication Date |
2014-05-29 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.843 |
Times cited |
22 |
Open Access |
|
|
|
Notes |
246102 IFOX; 278510 VORTEX; 246791 COUNTATOMS; Hercules; 312483 ESTEEM2; esteem2jra3 ECASJO; |
Approved |
Most recent IF: 2.843; 2014 IF: 2.436 |
|
|
Call Number |
UA @ lucian @ c:irua:118332UA @ admin @ c:irua:118332 |
Serial |
177 |
|
Permanent link to this record |
|
|
|
|
Author |
Dunin-Borkowski, R.E.; Lichte, H.; Tillmann, K.; Van Aert, S.; Van Tendeloo, G. |
|
|
Title |
Introduction to a special issue in honour of W. Owen Saxton, David J. Smith and Dirk Van Dyck on the occasion of their 65th birthdays |
Type |
Editorial |
|
Year |
2013 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
|
|
Volume |
134 |
Issue |
|
Pages |
1-1 |
|
|
Keywords |
Editorial; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Elsevier science bv |
Place of Publication |
Amsterdam |
Editor |
|
|
|
Language |
|
Wos |
000324474900001 |
Publication Date |
2013-07-24 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.843 |
Times cited |
1 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 2.843; 2013 IF: 2.745 |
|
|
Call Number |
UA @ lucian @ c:irua:109917 |
Serial |
1721 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Aert, S.; den Dekker, A.J.; van den Bos, A.; van Dyck, D. |
|
|
Title |
Statistical experimental design for quantitative atomic resolution transmission electron microscopy |
Type |
H1 Book chapter |
|
Year |
2004 |
Publication |
|
Abbreviated Journal |
Adv Imag Elect Phys |
|
|
Volume |
|
Issue |
|
Pages |
1-164 |
|
|
Keywords |
H1 Book chapter; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Academic Press |
Place of Publication |
San Diego, Calif. |
Editor |
|
|
|
Language |
|
Wos |
000223226700001 |
Publication Date |
2011-01-05 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1076-5670; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
13 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ lucian @ c:irua:47513 |
Serial |
3156 |
|
Permanent link to this record |
|
|
|
|
Author |
Liao, Z.L.; Green, R.J.; Gauquelin, N.; Gonnissen, J.; Van Aert, S.; Verbeeck, J.; et al. |
|
|
Title |
Engineering properties by long range symmetry propagation initiated at perovskite heterostructure interface |
Type |
A1 Journal article |
|
Year |
2016 |
Publication |
Advanced functional materials |
Abbreviated Journal |
Adv Funct Mater |
|
|
Volume |
|
Issue |
|
Pages |
1-25 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
In epitaxial thin film systems, the crystal structure and its symmetry deviate from the bulk counterpart due to various mechanisms such as epitaxial strain and interfacial structural coupling, which induce an accompanying change in their properties. In perovskite materials, the crystal symmetry can be described by rotations of 6-fold coordinated transition metal oxygen octahedra, which are found to be altered at interfaces. Here, we unravel how the local oxygen octahedral coupling (OOC) at perovskite heterostructural interfaces initiates a different symmetry in epitaxial films and provide design rules to induce various symmetries in thin films by careful selecting appropriate combinations of substrate/buffer/film. Very interestingly we discovered that these combinations lead to symmetry changes throughout the full thickness of the film. Our results provide a deep insight into understanding the origin of induced crystal symmetry in a perovskite heterostructure and an intelligent route to achieve unique functional properties. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Weinheim |
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1616-301x |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
12.124 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 12.124 |
|
|
Call Number |
UA @ lucian @ c:irua:134842 |
Serial |
4176 |
|
Permanent link to this record |
|
|
|
|
Author |
de Backer, A.; Fatermans, J.; den Dekker, A.J.; Van Aert, S. |
|
|
Title |
Introduction |
Type |
H2 Book chapter |
|
Year |
2021 |
Publication |
Advances in imaging and electron physics
T2 – Advances in imaging and electron physics |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
1-28 |
|
|
Keywords |
H2 Book chapter; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2021-03-06 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
217 |
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
978-0-12-824607-8; 1076-5670 |
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
Not_Open_Access |
|
|
Notes |
ERC Consolidator project funded by the European Union grant #770887 Picometrics |
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ admin @ c:irua:177525 |
Serial |
6784 |
|
Permanent link to this record |
|
|
|
|
Author |
Yu, C.-P.; Friedrich, T.; Jannis, D.; Van Aert, S.; Verbeeck, J. |
|
|
Title |
Real-Time Integration Center of Mass (riCOM) Reconstruction for 4D STEM |
Type |
A1 Journal article |
|
Year |
2022 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
|
|
Volume |
|
Issue |
|
Pages |
1-12 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
A real-time image reconstruction method for scanning transmission electron microscopy (STEM) is proposed. With an algorithm requiring only the center of mass of the diffraction pattern at one probe position at a time, it is able to update the resulting image each time a new probe position is visited without storing any intermediate diffraction patterns. The results show clear features at high spatial frequency, such as atomic column positions. It is also demonstrated that some common post-processing methods, such as band-pass filtering, can be directly integrated in the real-time processing flow. Compared with other reconstruction methods, the proposed method produces high-quality reconstructions with good noise robustness at extremely low memory and computational requirements. An efficient, interactive open source implementation of the concept is further presented, which is compatible with frame-based, as well as event-based camera/file types. This method provides the attractive feature of immediate feedback that microscope operators have become used to, for example, conventional high-angle annular dark field STEM imaging, allowing for rapid decision-making and fine-tuning to obtain the best possible images for beam-sensitive samples at the lowest possible dose. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000792176100001 |
Publication Date |
2022-04-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.8 |
Times cited |
7 |
Open Access |
OpenAccess |
|
|
Notes |
Bijzonder Onderzoeksfonds UGent; H2020 European Research Council, 770887 ; H2020 European Research Council, 823717 ; H2020 European Research Council, ESTEEM3 / 823717 ; H2020 European Research Council, PICOMETRICS / 770887 ; Fonds Wetenschappelijk Onderzoek, 30489208 ; Herculesstichting; esteem3reported; esteem3jra |
Approved |
Most recent IF: 2.8 |
|
|
Call Number |
EMAT @ emat @c:irua:188538 |
Serial |
7068 |
|
Permanent link to this record |
|
|
|
|
Author |
De wael, A.; De Backer, A.; Yu, C.-P.; Sentürk, D.G.; Lobato, I.; Faes, C.; Van Aert, S. |
|
|
Title |
Three Approaches for Representing the Statistical Uncertainty on Atom-Counting Results in Quantitative ADF STEM |
Type |
A1 Journal article |
|
Year |
2022 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
|
|
Volume |
|
Issue |
|
Pages |
1-9 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
A decade ago, a statistics-based method was introduced to count the number of atoms from annular dark-field scanning transmission electron microscopy (ADF STEM) images. In the past years, this method was successfully applied to nanocrystals of arbitrary shape, size, and composition (and its high accuracy and precision has been demonstrated). However, the counting results obtained from this statistical framework are so far presented without a visualization of the actual uncertainty about this estimate. In this paper, we present three approaches that can be used to represent counting results together with their statistical error, and discuss which approach is most suited for further use based on simulations and an experimental ADF STEM image. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000854930500001 |
Publication Date |
2022-09-19 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
UA library record; WoS full record |
|
|
Impact Factor |
2.8 |
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
This project has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (Grant Agreement No. 770887 and No. 823717 ESTEEM3). The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through grants to A.D.w. and A.D.B. and projects G.0502.18N, G.0267.18N, and EOS 30489208. S.V.A. acknowledges TOP BOF funding from the University of Antwerp. The authors are grateful to L.M. Liz-Marzán (CIC biomaGUNE and Ikerbasque) for providing the samples. esteem3reported; esteem3jra |
Approved |
Most recent IF: 2.8 |
|
|
Call Number |
EMAT @ emat @c:irua:190585 |
Serial |
7119 |
|
Permanent link to this record |
|
|
|
|
Author |
Cioni, M.; Delle Piane, M.; Polino, D.; Rapetti, D.; Crippa, M.; Arslan Irmak, E.; Van Aert, S.; Bals, S.; Pavan, G.M. |
|
|
Title |
Sampling real-time atomic dynamics in metal nanoparticles by combining experiments, simulations, and machine learning |
Type |
A1 Journal article |
|
Year |
2024 |
Publication |
Advanced Science |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
1-13 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
Even at low temperatures, metal nanoparticles (NPs) possess atomic dynamics that are key for their properties but challenging to elucidate. Recent experimental advances allow obtaining atomic-resolution snapshots of the NPs in realistic regimes, but data acquisition limitations hinder the experimental reconstruction of the atomic dynamics present within them. Molecular simulations have the advantage that these allow directly tracking the motion of atoms over time. However, these typically start from ideal/perfect NP structures and, suffering from sampling limits, provide results that are often dependent on the initial/putative structure and remain purely indicative. Here, by combining state-of-the-art experimental and computational approaches, how it is possible to tackle the limitations of both approaches and resolve the atomistic dynamics present in metal NPs in realistic conditions is demonstrated. Annular dark-field scanning transmission electron microscopy enables the acquisition of ten high-resolution images of an Au NP at intervals of 0.6 s. These are used to reconstruct atomistic 3D models of the real NP used to run ten independent molecular dynamics simulations. Machine learning analyses of the simulation trajectories allow resolving the real-time atomic dynamics present within the NP. This provides a robust combined experimental/computational approach to characterize the structural dynamics of metal NPs in realistic conditions. Experimental and computational techniques are bridged to unveil atomic dynamics in gold nanoparticles (NPs), using annular dark-field scanning transmission electron microscopy and molecular dynamics simulations informed by machine learning. The approach provides unprecedented insights into the real-time structural behaviors of NPs, merging state-of-the-art techniques to accurately characterize their dynamics under realistic conditions. image |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
001206888000001 |
Publication Date |
2024-04-24 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2198-3844 |
ISBN |
|
Additional Links |
UA library record; WoS full record |
|
|
Impact Factor |
15.1 |
Times cited |
|
Open Access |
|
|
|
Notes |
This work was supported by the funding received by the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation program (grant agreement no. 818776- DYNAPOL, no. 770887 PICOMETRICS and no. 815128 REALNANO). The authors also acknowledge the computational resources provided by the Swiss National Supercomputing Center (CSCS), by CINECA, and the Research Foundation Flanders (FWO, Belgium) G.0346.21N. |
Approved |
Most recent IF: 15.1; 2024 IF: 9.034 |
|
|
Call Number |
UA @ admin @ c:irua:205442 |
Serial |
9171 |
|
Permanent link to this record |