toggle visibility
Search within Results:
Display Options:

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Zarenia, M.; Vasilopoulos, P.; Pourtolami, N.; Peeters, F.M. url  doi
openurl 
  Title Landau-level dispersion and the quantum Hall plateaus in bilayer graphene Type P1 Proceeding
  Year 2013 Publication AIP conference proceedings Abbreviated Journal  
  Volume 1566 Issue Pages 275-276  
  Keywords P1 Proceeding; Condensed Matter Theory (CMT)  
  Abstract We study the quantum Hall effect (QHE) in bilayer graphene using the Kubo-Greenwood formula. At zero temperature the Hall conductivity sigma(yx) is given by sigma(yx) – 4(N + 1)e(2)/h with N the index of the highest occupied Landau level (LL). Including the dispersion of the LLs and their width, due to e. g. scattering by impurities, produces the plateau of the n = 0 LL in agreement with experimental results on doped samples and similar theoretical results on single-layer graphene plateaus widen with impurity concentration. Further, the evaluated resistivity rho(xx) exhibits a strong, oscillatory dependence on the electron concentration. Explicit results are obtained for delta-function impurities.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication New York Editor  
  Language Wos 000331793000137 Publication Date 2014-01-03  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Additional Links (up) UA library record; WoS full record  
  Impact Factor Times cited Open Access  
  Notes ; This work was supported by the Flemish Science Foundation (FWO-Vl), the European Science Foundation (project CONGRAN) and the Canadian NSERC Grant No. OGP0121756. ; Approved Most recent IF: NA  
  Call Number UA @ lucian @ c:irua:115871 Serial 1770  
Permanent link to this record
 

 
Author Zhang, G.; Turner, S.; Ekimov, E.A.; Vanacken, J.; Timmermans, M.; Samuely, T.; Sidorov, V.A.; Stishov, S.M.; Lu, Y.; Deloof, B.; Goderis, B.; Van Tendeloo, G.; Van de Vondel, J.; Moshchalkov, V.V.; pdf  doi
openurl 
  Title Global and local superconductivity in boron-doped granular diamond Type A1 Journal article
  Year 2014 Publication Advanced materials Abbreviated Journal Adv Mater  
  Volume 26 Issue 13 Pages 2034-2040  
  Keywords A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT)  
  Abstract Strong granularity-correlated and intragrain modulations of the superconducting order parameter are demonstrated in heavily boron-doped diamond situated not yet in the vicinity of the metal-insulator transition. These modulations at the superconducting state (SC) and at the global normal state (NS) above the resistive superconducting transition, reveal that local Cooper pairing sets in prior to the global phase coherence.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Weinheim Editor  
  Language Wos 000333616700008 Publication Date 2013-12-16  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0935-9648; ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor 19.791 Times cited 34 Open Access  
  Notes Methusalem Funding; FWO projects; MP1201 COST Action; ERC Grant N246791-COUNTATOMS; post-doctoral grant (S.T.) and for project no. G.0568.10N.;Hercules Foundation Approved Most recent IF: 19.791; 2014 IF: 17.493  
  Call Number UA @ lucian @ c:irua:116150 Serial 1346  
Permanent link to this record
 

 
Author van Grieken, R.; Gijbels, R.; Speecke, A.; Hoste, J. pdf  doi
openurl 
  Title The determination of silicon in steel by 14-mev neutron activation analysis Type A1 Journal article
  Year 1968 Publication Analytica chimica acta Abbreviated Journal Anal Chim Acta  
  Volume 43 Issue Pages 199-209  
  Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract A fast (25 min) non-destructive determination of silicon in steel by 14-MeV neutron activation is described. The 1.78-MeV 28Al activity, induced by the reaction 28Si(n,p)28Al, is counted on a NaI(Tl) detector. An oxygen flux monitor is used to normalise to the same neutron flux. Two methods are described to correct for the 56Mn activity (2.58 h), induced into the iron matrix via 56Fe(n,p)56Mn. Nuclear interferences of phosphorus and aluminium have been examined. Special attention has been paid to stainless steels. A sensitivity of 0.02 to 0.05% of silicon is obtained. The precision is 2 to 3% for steels containing above 1% silicon, and 7% for 0.1% of silicon.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Amsterdam Editor  
  Language Wos A1968C007600004 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2670; ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor 4.513 Times cited 19 Open Access  
  Notes Approved no  
  Call Number UA @ lucian @ c:irua:116357 Serial 673  
Permanent link to this record
 

 
Author van Grieken, R.; Gijbels, R.; Speecke, A.; Hoste, J. pdf  doi
openurl 
  Title Internal standard activation analysis of silicon in steel Type A1 Journal article
  Year 1968 Publication Analytica chimica acta Abbreviated Journal Anal Chim Acta  
  Volume 43 Issue Pages 381-395  
  Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Non-destructive 14-MeV neutron activation analysis for silicon in steel has been applied with 56Mn as internal standard.56Mn is formed from the iron matrix via the 56Fe(n,p)56Mn reaction. Several methods of internal standardisation via56Mn are discussed. The 0.84-MeV photopeak of 56Mn is recommended if steel samples of about the same composition are to be analysed. Chemically analysed steel samples are used as silicon standards. A precision of 0.7% was obtained for an analysis plus standardisation time of 13 min. Special attention was paid to interferences produced by concentration changes of impurity elements. Several possible sources of errors were investigated.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Amsterdam Editor  
  Language Wos A1968C185100003 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2670; ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor 4.513 Times cited 14 Open Access  
  Notes Approved no  
  Call Number UA @ lucian @ c:irua:116358 Serial 1701  
Permanent link to this record
 

 
Author Van Grieken, R.; Speecke, A.; Hoste, J. pdf  doi
openurl 
  Title The determination of copper in iron and steel by 14-Mev neutron activation analysis Type A1 Journal article
  Year 1970 Publication Analytica chimica acta Abbreviated Journal  
  Volume 51 Issue 2 Pages 151-162  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract A fast (10 min) non-destructive determination of copper in. steel and cast iron by 14-MeV neutron activation analysis is described. The 0.511-MeV annihilation radiation of62Cu (T1/2=9.8 min), induced by the reaction63Cu(n,2n)62Cu, is counted by two opposing NaI(Tl) detectors operating in coincidence. An oxygen flux monitor is used to normalise the irradiations. For high phosphorus contents, two measurements are made and the 9-min activity contribution is calculated. As the iron content of the samples is known, the use of pure iron samples allows correction for53Fe activity from the reaction54Fe(n,2n)53Fe(T1/2= 8.9 min). When the phosphorus and silicon activities are low, the procedure of counting and computing can be greatly simplified. Nuclear interferences of most common alloying and impurity elements were investigated.The precision is 23% for steels containing above 1% Cu, andCa. 10% for 0.1%Cu.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1970H034700002 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2670; 1873-4324 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116360 Serial 7778  
Permanent link to this record
 

 
Author Van Grieken, R.; Speecke, A.; Hoste, J. pdf  doi
openurl 
  Title On the precision of oxygen determinations in steel by 14-MeVv neutron activation Type A1 Journal article
  Year 1970 Publication Analytica chimica acta Abbreviated Journal  
  Volume 52 Issue 2 Pages 275-280  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract The precision of the 14-MeV neutron activation determination of oxygen in steel has been examined as a function of the oxygen content for a large number of steel and cast iron samples. The experimental and the statistically expected standard deviations have been compared. In the conditions used, 2.5 counts from 16N were registered for each p.p.m. of oxygen in the samples. The neutron flux was monitored by a simultaneously irradiated oxygen standard.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2670; 1873-4324 ISBN Additional Links (up) UA library record  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116362 Serial 8332  
Permanent link to this record
 

 
Author Vandecasteele, C.; van Grieken, R.; Gijbels, R.; Speecke, A. pdf  doi
openurl 
  Title Systematic errors in 14-MeV neutron activation analysis for oxygen : part 1 : neutron and γ-ray attenuation effects Type A1 Journal article
  Year 1973 Publication Analytica chimica acta Abbreviated Journal Anal Chim Acta  
  Volume 64 Issue 2 Pages 187-196  
  Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract A detailed account is given of neutron and γ-ray attenuation effects in 14-MeV neutron activation analysis of oxygen. Appropriate neutron cross-section values have been determined in two different ways and compared with literature values. It appears that the attenuation process is best described in terms of nonelastic scattering cross-sections. It is also shown that the narrow beam total γ-ray attenuation coefficients at 6 MeV, given in the literature are suitable for correction purposes if 16N γ-rays are counted with a window of 4.56.5 MeV. Attention was paid to the contribution of β-rays when the 16N activity is counted in this energy interval with a NaI(Tl) detector.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Amsterdam Editor  
  Language Wos A1973P353000003 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2670; ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor 4.513 Times cited 11 Open Access  
  Notes Approved CHEMISTRY, PHYSICAL 54/144 Q2 # PHYSICS, ATOMIC, MOLECULAR & CHEMICAL 9/35 Q2 #  
  Call Number UA @ lucian @ c:irua:116363 Serial 3464  
Permanent link to this record
 

 
Author Vandecasteele, C.; van Grieken, R.; Gijbels, R.; Speecke, A. pdf  doi
openurl 
  Title Systematic errors in 14-MeV neutron activation analysis for oxygen : part 2 : a general standardization method for the determination of oxygen Type A1 Journal article
  Year 1973 Publication Analytica chimica acta Abbreviated Journal Anal Chim Acta  
  Volume 65 Issue 1 Pages 1-17  
  Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract A general standardization method is described for the determination of oxygen in solid samples via the 16O(n,p)16N reaction. Two systems of flux monitoring are considered: the sample versus standard comparator method and BF3 monitoring. The average flux in sample and standard, fast neutron shielding, fast neutron scattering, absorption of fast neutrons, absorption of 16N γ-rays and counting efficiency of sample and standard are considered. The influence of the target diameter on the obtained correction factors has also been studied. Total achievable accuracy is believed to be about 1%.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Amsterdam Editor  
  Language Wos A1973Q019300001 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2670; ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor 4.513 Times cited 12 Open Access  
  Notes Approved  
  Call Number UA @ lucian @ c:irua:116364 Serial 3465  
Permanent link to this record
 

 
Author Gijbels, R.; Dams, R. pdf  doi
openurl 
  Title Determination of silicon in natural and pollution aerosols by 14-MeV neutron activation analysis Type A1 Journal article
  Year 1973 Publication Analytica chimica acta Abbreviated Journal Anal Chim Acta  
  Volume 63 Issue 2 Pages 369-381  
  Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)  
  Abstract The determination of silicon via the 28Si(n,p)28 Al reaction by means of 14-MeV neutrons is applied to the analysis of pollution and natural aerosols. A Whatman 41 filter (40 cm2) on which airborne particulate material has been collected is compressed into a 3 × 12.7 mm pellet. Standards are prepared in the same way from clean filters spiked with a silicate solution. After a 50-s irradiation and a 75-s decay time, the sample is counted for 2 min with 5 × 5 NaI(Tl) well detector. The 1.779-MeV photopeak of 28Al is measured with a single channel sealer chain or with a multichannel analyser. The reproducibility, sensitivity and liability to interference from other elements were investigated for both counting systems. The homogeneity of the pellets and the filters was checked. The overall precision of one single-channel determination was estimated to be 3.5% after a 24-h high-volume sampling time. Samples collected in urban, industrial and remote areas with concentrations ranging from 0.05 to 15 μg Si m-3 air were analysed and the results are discussed.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Amsterdam Editor  
  Language Wos A1973O944700013 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2670; ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor 4.513 Times cited 16 Open Access  
  Notes Approved no  
  Call Number UA @ lucian @ c:irua:116365 Serial 672  
Permanent link to this record
 

 
Author Vandecasteele, C.; Van Grieken, R.; Hoste, J. pdf  doi
openurl 
  Title Simultaneous determination of chromium and silicon in steel by 14-mev neutron activation analysis Type A1 Journal article
  Year 1974 Publication Analytica chimica acta Abbreviated Journal  
  Volume 72 Issue 1 Pages 31-36  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Chromium and silicon are determined simultaneously in steel by 14-MeV neutron activation analysis. The activities of 52V(Eγ=1.43 MeV,TView the MathML source=3.76 min) from 52Cr(n,p)52V and 28Al (Eγ=1.78 MeV; TView the MathML source=2.24 min) from 28Si(n,p)28Al are evaluated by mixed γ-ray spectrometry. The influence of manganese and phosphorus, the main interfering elements, is negligible for most stainless steels. The count rate should be limited, to avoid 52V pulse pile-up effects interfering in the 28Al energy region. Precisions in the 2-10% range are reached, depending on the concentrations, for a 10-min analysis time. Results for a series of steel samples are compared with industrial analyses.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1974U036600002 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2670; 1873-4324 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116366 Serial 8527  
Permanent link to this record
 

 
Author Smits, J.; Van Grieken, R. pdf  doi
openurl 
  Title Optimization of a simple spotting procedure for x-ray fluorescence analysis of waters Type A1 Journal article
  Year 1977 Publication Analytica chimica acta Abbreviated Journal  
  Volume 88 Issue 1 Pages 97-107  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Several sample preparation methods for waters for energy-dispersive x.r.f. were examined, as well as the influence of sample size on the analytical characteristics. The most satisfactory simple, rapid method proved to be spotting of 1.5 ml of water sample on a Whatman-41 cellulose filter paper provided with a wax ring of 29-mm diameter and evaporating the water with an unheated air stream from underneath. Sensitivities are below 100 p.p.b. for most elements and often below 50 p.p.b. when the optimal secondary fluorescer is used. Accuracy and precision are usually in the 1520 % range. The method is applicable to many dilute aqueous solutions as is illustrated by analysis of industrial water samples and ashed biological material.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1977CQ82600011 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2670; 1873-4324 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116367 Serial 8337  
Permanent link to this record
 

 
Author Vanderborght, B.; Van Grieken, R. pdf  doi
openurl 
  Title Reduction of trace metal levels in analytical-grade activated carbon Type A1 Journal article
  Year 1977 Publication Analytica chimica acta Abbreviated Journal  
  Volume 89 Issue 2 Pages 399-402  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1977DB52500022 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2670; 1873-4324 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116368 Serial 8466  
Permanent link to this record
 

 
Author Smits, J.; Nelissen, J.; Van Grieken, R. pdf  doi
openurl 
  Title Comparison of preconcentration procedures for trace metals in natural waters Type A1 Journal article
  Year 1979 Publication Analytica chimica acta Abbreviated Journal  
  Volume 111 Issue Pages 215-226  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract The relative merits of eight procedures for preconcentrations of trace metal ions from natural water samples and synthetic solutions are evaluated. Spikes (100 μg l−1 ) of Mn, Co, Zn, Eu, Cs and Ba and the corresponding radioactive tracers were added to batches of drinking water, estuarine water, sea water, ground water, twice-distilled water and ahumic material solution. After equilibration for 25 months, the following techniques were applied: passage through columns of Dowex Al chelating resin and ofsilylated silica gel, filtration through laminate membrane filters and chelating diethylenetriamine cellulose filters, precipitation with sodium diethyldithiocarbamate and l-(2-pyridylazo)-2-naphthol, extraction with ammonium pyrrolidinedithiocarbamate, and chelation by 8-quinolinol (oxine) followed by adsorption on activated carbon. The quantitative characteristics of these techniques and the influence of the water matrix effects are discussed, as well as the applicability for x-ray fluorescence analysis.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1979HX09300018 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2670; 1873-4324 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116369 Serial 7695  
Permanent link to this record
 

 
Author Van Grieken, R.; Van de Velde, R.; Robberecht, H. pdf  doi
openurl 
  Title Sample contamination from a commercial grinding unit Type A1 Journal article
  Year 1980 Publication Analytica chimica acta Abbreviated Journal  
  Volume 118 Issue 1 Pages 137-143  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract The contamination of ground samples by a commercially available Lovibond McCrone Micronizing Mill is discussed. Tracer and weighing experiments showed that abrasion of corundum grinding elements was important, introducing 620 mg of abrasion products per minute of wet grinding. Agate grinding elements were abraded at ⩽6 mg min-1. The abrasion products and grinding elements were analyzed by x-ray fluorescence, spark-source mass spectrometry and neutron activation analysis. Contamination in trace element analysis of geological materials is likely to be negligible for agate grinding elements and, except for a few transition metals, also for corundum grinding elements. Contamination of typical biological samples is significant for a few elements even when agate elements are used, and is absolutely prohibitive for trace analysis when corundum elements are used.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1980JZ95100016 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2670; 1873-4324 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116436 Serial 8492  
Permanent link to this record
 

 
Author Smits, J.; Van Grieken, R. pdf  doi
openurl 
  Title Enrichment of trace anions from water with 2,2'-diaminodiethylamine cellulose filters Type A1 Journal article
  Year 1981 Publication Analytica chimica acta Abbreviated Journal  
  Volume 123 Issue Pages 9-17  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Cellulose filters with immobilized 2,2'-diaminodiethylamine (DEN) functional groups are studied for trace anion preconcentration from aqueous solution, with subsequent x-ray fluorescence measurements. For most oxoanions with a central metal atom, nearly quantitative collection can be achieved by 10-cm2 DEN filters under the following optimized conditions: pH 36, filtration rate up to 0.5 ml cm-2 min-1, and sample volume up to 100 ml cm-2. The collection yield is independent of the trace oxoanion concentration up to at least 1.5 μmol cm-2. Although the DEN filter exhibits some selectivity towards oxoanions with a central metal atom, ionic strength affects the results; the collection efficiency is strongly depressed with salt (e.g. NaCl) concentrations above 0.01 M. The applicability of the DEN filter in anion collection is therefore limited to dilute solutions.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1981LA22400002 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2670; 1873-4324 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116437 Serial 7922  
Permanent link to this record
 

 
Author Vos, L.; Robberecht, H.; Van Dyck, P.; Van Grieken, R. pdf  doi
openurl 
  Title Multi-element analysis of urine by energy-dispersive x-ray fluorescence spectrometry Type A1 Journal article
  Year 1981 Publication Analytica chimica acta Abbreviated Journal  
  Volume 130 Issue 1 Pages 167-175  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract For multi-element analysis of human urine, 25-ml samples doped with yttrium as internal standard are evaporated gently and then ashed up to 460°C overnight. The residue is pelletized and analysed by energy-dispersive x-ray fluorescence. Acid addition to facilitate the digestion is not mandatory. Recoveries are nearly quantitative for traces of Fe, Ni, Cu, Zn and Sr, to a lesser extent for lead, but not for arsenic or selenium. The standard deviation per measurement is typically around 6%. The detection limits are such that some 10 elements can be determined simultaneously in normal urine, and possibly more in cases of importance to toxicology or industrial hygiene.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1981ME98900017 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2670; 1873-4324 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116439 Serial 8285  
Permanent link to this record
 

 
Author Robberecht, H.; Van Grieken, R.; Shani, J.; Barak, S. pdf  doi
openurl 
  Title Evaluation of multi-element analysis of blood serum by energy-dispersive x-ray spectrometry Type A1 Journal article
  Year 1982 Publication Analytica chimica acta Abbreviated Journal  
  Volume 136 Issue Pages 285-292  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Conventional energy-dispersive x-ray fluorescence is applied in the analysis of blood serum to give the concentrations of 710 elements simultaneously with minimal manipulation of the samples. Simple spotting onto a Mylar carrier of 250 μl of serum, doped with two internal standards, was chosen as the sample preparation step. Some 200 serum samples, analyzed in replicate (n = 26), were used to evaluate this procedure. The detection limits are 4 μg ml-1 for K and Ca, 0.50.2 μg ml-1 for Fe, Cu, Pb and Zn, and less than 0.1 μg ml-1 for Se, Rb and Sr. Well above these limits, the standard deviation is around 10%. Comparison with the results of other measurements on the same samples indicates an accuracy of that order. The simplicity and high throughput, and the possibility of automating the x.r.f. measurements, make the proposed procedure suitable for screening large numbers of sera.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1982NL48600032 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2670; 1873-4324 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116440 Serial 7940  
Permanent link to this record
 

 
Author Van Grieken, R. pdf  doi
openurl 
  Title Preconcentration methods for the analysis of water by X-ray spectrometric techniques Type A1 Journal article
  Year 1982 Publication Analytica chimica acta Abbreviated Journal  
  Volume 143 Issue Pages 3-34  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract All published procedures for multi-element preconcentration of trace elements, prior to x-ray fluorescence analysis of water, are reviewed and critically evaluated. Most preconcentration methods applied to the determination of single elements in water are also listed.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1982PT27300002 Publication Date 2002-10-14  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2670; 1873-4324 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116441 Serial 8401  
Permanent link to this record
 

 
Author Robberecht, H.; Van Grieken, R. pdf  doi
openurl 
  Title Determination of trace selenium in biological material by preconcentration and X-ray emission spectrometry Type A1 Journal article
  Year 1983 Publication Analytica chimica acta Abbreviated Journal  
  Volume 147 Issue Pages 113-121  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Selenium is determined in the ng g−1 to μg g−1 range in biological and environmental samples. A wet digestion procedure was optimized with respect to volatility losses and recovery yields, by using 75Se metabolically incorporated into rat organs. Selenium is preconcentrated from the digestion liquid by a two-step reduction with 4 M HCl and ascorbic acid. The colloidal selenium formed is adsorbed on activated carbon and filtered on a Nucleopore membrane for measurement by energy-dispersive x-ray fluorescence. Almost complete recovery was obtained, and the detection limit was 20 ng, corresponding to 10 ng g−1 for a 2-g sample. Biological reference materials were analyzed with satisfactory results, and the accuracy of the method was good.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1983QH42100010 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2670; 1873-4324 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116442 Serial 7794  
Permanent link to this record
 

 
Author Vos, L.; Van Grieken, R. pdf  doi
openurl 
  Title Preparation of conducting electrodes from biological samples for multi-element trace analysis by spark-source mass spectrometry or emission spectrometry Type A1 Journal article
  Year 1984 Publication Analytica chimica acta Abbreviated Journal  
  Volume 164 Issue Pages 83-90  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Four decomposition procedures frequently used for biological material (dry ashing, open wet digestion, wet digestion in a teflon bomb and low-temperature ashing) are optimized for the conversion of biological samples to conducting electrodes suitable for multi-element trace determinations by spark-source mass spectrometry or emission spectrometry. The optimized procedures are evaluated with respect to contamination, retention and preconcentration of the trace elements, homogeneity of the electrodes and precision of the final results. Both dry-ashing methods are prone to losses by volatilization; simple dry ashing suffers from contamination problems during electrode preparation. Wet digestion gives better precision; digestion with nitric/sulfuric acids in an open flask is the method of choice for most elements being simpler and giving lower blanks than the bomb method.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1984ABC2700007 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2670; 1873-4324 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116443 Serial 8411  
Permanent link to this record
 

 
Author Vos, L.; Komy, G.; Reggers, G.; Roekens, E.; Van Grieken, R. pdf  doi
openurl 
  Title Determination of trace metals in rain water by differential-pulse stripping voltammetry Type A1 Journal article
  Year 1986 Publication Analytica chimica acta Abbreviated Journal  
  Volume 184 Issue Pages 271-280  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Differential-pulse stripping voltammetry is applied to measure zinc, cadmium, lead and copper by anodic stripping and selenium(IV) by cathodic stripping in rain water at pH 2; subsequently, at pH 9,1, manganese is measured by anodic stripping on the same portion, and cobalt and nickel are measured in the adsorptive mode after formation of their dimethylglyoximates. The instrumental parameters are optimized. The linear ranges, mutual interferences and detection limits are studied. Excellent accuracy is demonstrated; the standard deviation is around 15% at 2.550 μg l−1 levels. The method is shown to be applicable for rain water.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1986D964700026 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2670; 1873-4324 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116444 Serial 7793  
Permanent link to this record
 

 
Author Lins Galdino, S.M.; Costa Dantas, C.; Van Grieken, R. pdf  doi
openurl 
  Title Radio-isotope neutron activation analysis for vanadium, manganese and tungsten in alloy steels Type A1 Journal article
  Year 1987 Publication Analytica chimica acta Abbreviated Journal  
  Volume 196 Issue Pages 337-343  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract An instrumental neutron activation method for V, Mn and W in alloy steels with a 241 Am/Be isotopic neutron source is described. The samples were irradiated to induce the nuclear reactions 51V(n, γ) 52V, 55Mn(n, γ)56Mn, and 186W(n, γ)187W. The activities were measured with a NaI(TI) detector. Interferences on the measured photopeaks were shown to be negligible by measuring the half-lives of 62V, 56Mn and 187W.These thre elementes were determined in the range 1.512.9% in special steels; manganese in the range 0.51.6% was measured in cast irons. Calibration was done by comparison with results from wet chemistry and x-ray fluorescence spectrometry. The processing times for the vanadium, manganese and tungsten determinations were 11 min, 3 h and 26.3 h, respectively, but these were reduced greatly by intoruding a scheme wherein six samples were simultaneously irradiated and the 56Mn and 187W nuclides were measured sequentially for a series of 66 samples. The average processing time was reduced to 45 min for tungsten with a precision of 4.0% and accuracy of 3.4% and 22.8 min for manganese with a precision of 3.8% and accuracy of 3.1%.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1987K058900044 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2670; 1873-4324 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116445 Serial 8449  
Permanent link to this record
 

 
Author Leysen, L.; Roekens, E.; Komy, Z.; Van Grieken, R. pdf  doi
openurl 
  Title A study of the weathering of an historic building Type A1 Journal article
  Year 1987 Publication Analytica chimica acta Abbreviated Journal  
  Volume 195 Issue Pages 247-255  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Various bulk and surface analytical techniques were used to study the chemical deterioration of the 13th-to-15th century limestone cathedral in Mechelen, Belgium. The weathering crust on the walls was found to be rich in sulfate, regardless of the geographic orientation. Nitrate and chloride were only detected in minor amounts in the crust and run-off samples. Attack by gaseous sulfur compounds seems to play a dominant role in the stone deterioration mechanism. Electron microprobe analysis showed predominantly bar-shaped gypsum crystals in the crust, and laser microprobe mass spectrometry showed that carbon seems to be responsible for the blackness of most crust samples. Automated electron microprobe analysis also indicated significant differences in the analytical composition of suspensions in run-off water and in rain-water.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1987K019500022 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2670; 1873-4324 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116446 Serial 8608  
Permanent link to this record
 

 
Author Otten, P.; Bruynseels, F.; Van Grieken, R. pdf  doi
openurl 
  Title Study of inorganic ammonium compounds in individual marine aerosol particles by laser microprobe mass spectrometry Type A1 Journal article
  Year 1987 Publication Analytica chimica acta Abbreviated Journal  
  Volume 195 Issue Pages 117-124  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Ammonia is important in the atmosphere because it neutralizes acidic species. The relative importance of different inorganic ammonium compounds (chloride, nitrate and sulfate) in marine air chemistry was studied by single-particle characterization with the laser microprobe mass analyser. Standard aerosols were generated as a reference for compound identification, based on the fingerprint spectra obtained, and calculation of the relative sensitivity achieved for different ions in a marine aerosol matrix. The relative sensitivity for ammonium was low. Aerosol samples were collected in the Southern Bight of the North Sea under different meteorological conditions and examined for their ammonium compounds. Samples collected during an inversion period with continental influences showed a much higher content in all particles than samples collected under different meteorological conditions, where ammonium was mostly detected in the submicrometer particle-size range.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1987K019500010 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2670; 1873-4324 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116447 Serial 8601  
Permanent link to this record
 

 
Author Verbueken, A.H.; Van Grieken, R.E.; de Broe, M.E.; Wedeen, R.P. pdf  doi
openurl 
  Title Identification of inorganic and organic microliths in kidney sections by laser microprobe mass spectrometry Type A1 Journal article
  Year 1987 Publication Analytica chimica acta Abbreviated Journal  
  Volume 195 Issue Pages 97-115  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)  
  Abstract Laser microprobe mass spectrometry is used to identify intrarenal microliths; they appear to consist of either oxalate, urate or phosphate. Crystalline and amorphous deposits in rat and human kidney are pin-pointed by the laser beam and their chemical composition determined by mass spectrometry. The method has the potential for wide application in the identification of single organic, inorganic or combination crystals in histological sections.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1987K019500009 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2670; 1873-4324 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116448 Serial 8055  
Permanent link to this record
 

 
Author Komy, Z.; Roekens, E.; Van Grieken, R. pdf  doi
openurl 
  Title Analysis of rain water by differential-pulse stripping voltammetry in nitric acid medium Type A1 Journal article
  Year 1988 Publication Analytica chimica acta Abbreviated Journal  
  Volume 204 Issue Pages 179-187  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Differential-pulse anodic stripping voltammetry is applied to determine cadmium, lead and copper in rain water acidified with nitric acid to pH 1.5, and zinc after partial neutralization to pH 4.5. Subsequently, cobalt and nickel are measured in the adsorptive mode after formation of their dimethylglyoximates. The effects of pH on the stripping peaks for Zn, Cd, Pb and Cu and of chloride on the stripping peak of copper are reported. Good agreement is found with d.p.s.v. determinations in hydrochloric acid medium and with a.a.s. measurements in most cases. Excellent accuracy is demonstrated; the average relative standard deviation per measurement appears to be between 12 and 22% for the overall analytical procedure for concentrations of 0.1550 μgl−1 of the various metals in the samples.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1988M945900016 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2670; 1873-4324 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116449 Serial 7450  
Permanent link to this record
 

 
Author Van Grieken, R.; Speecke, A.; Hoste, J. doi  openurl
  Title Simultaneous determination of silicon and phosphorus in cast iron by 14 MeV neutron activation analysis Type A3 Journal article
  Year 1970 Publication Journal of radioanalytical chemistry Abbreviated Journal  
  Volume 6 Issue 2 Pages 385-398  
  Keywords A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract A fast (10 min), non-destructive simultaneous determination of silicon and phosphorus in cast iron and steel by 14 MeV neutron activation was developed. The 1.78 MeV28Al activity (T=2.24 min) induced by the reaction28Si(n, p)28Al is counted on a NaI(Tl) detector. Two measurements are made to correct for the 1.81 MeV56Mn activity (T=2.58 hr) from the iron matrix. However,28Al is also produced via31P(n, α)28Al. By (n, 2n) reaction, phosphorus yields also30P (T=2.6 min), the 0.511 MeV annihilation radiation of which is counted by two opposite NaI(Tl) detectors in coincidence. Again, two successive coincidence measurements are carried out in order to take into account the53Fe activity (β+; T=8.9 min) from54Fe(n, 2n)53Fe. The28Al measurement is appropriately corrected via the computed phosphorus content. An oxygen flux monitor was used to normalize to the same flux. Nuclear interferences have been examined. Special attention has been paid to the presence of copper. The standard deviation for phosphorus being as high as ca. 0.09% P for a single determination, this technique can only be practical as an independent phosphorus analysis for high phosphorus cast irons. The precision on the28Al measurement is 5% relative for 0.2% Si and 2.5% above 1% Si.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos Publication Date 2006-10-11  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0134-0719; 2064-2857 ISBN Additional Links (up) UA library record  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116450 Serial 8528  
Permanent link to this record
 

 
Author Van Schandevijl, R.; Van Grieken, R.; Hoste, J. doi  openurl
  Title The half-life of 28Al Type A3 Journal article
  Year 1971 Publication Journal of radioanalytical chemistry Abbreviated Journal  
  Volume 9 Issue 1 Pages 55-60  
  Keywords A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract The half-life of28Al was redetermined on aluminium samples of different origin. Three different counting techniques were applied. The availability of highly purified samples (up to 99.9999%), the use of very fast electronic counting equipment and a complete automatisation allowed a good precision to be obtained in the final result of 2.2405 min.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos Publication Date 2006-10-11  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0134-0719; 2064-2857 ISBN Additional Links (up) UA library record  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116451 Serial 8016  
Permanent link to this record
 

 
Author Van Grieken, R.; Speecke, A.; Hoste, J. doi  openurl
  Title Spatial neutron flux distributions around A 14 MeV neutron generator Type A3 Journal article
  Year 1972 Publication Journal of radioanalytical chemistry Abbreviated Journal  
  Volume 10 Issue 1 Pages 95-104  
  Keywords A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract The neutron flux distribution in the vicinity of 30, 20 and 10 mm diameter targets is measured by irradiating concentric ring-type iron monitors at different distances from the target and counting the induced56Mn activity. Considering the many uncertainties, satisfactory agreement was found between theory and experiment.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos Publication Date 2006-11-07  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0134-0719; 2064-2857 ISBN Additional Links (up) UA library record  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116452 Serial 8567  
Permanent link to this record
 

 
Author Van Grieken, R.; Speecke, A.; Hoste, J. doi  openurl
  Title Geometry errors in 14 MeV neutron activation analysis Type A3 Journal article
  Year 1973 Publication Journal of radioanalytical chemistry Abbreviated Journal  
  Volume 13 Issue 1 Pages 225-233  
  Keywords A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract The effects of inaccurate sample sizes and sample positioning on 14 MeV neutron activation analysis results are estimated for 30, 20 and 10 mm diameter targets. It appears that axial positioning is the most critical parameter and that using a larger tritium target will yield an overall improvement of the reproducibility.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos Publication Date 2006-10-11  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0134-0719; 2064-2857 ISBN Additional Links (up) UA library record  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116453 Serial 7999  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: