Home | << 1 2 3 >> |
Records | |||||
---|---|---|---|---|---|
Author | Lepot, K.; Addad, A.; Knoll, A.H.; Wang, J.; Troadec, D.; Béché, A.; Javaux, E.J. | ||||
Title | Iron minerals within specific microfossil morphospecies of the 1.88 Ga Gunflint Formation | Type | A1 Journal article | ||
Year | 2017 | Publication | Nature communications | Abbreviated Journal | Nat Commun |
Volume | 8 | Issue | 8 | Pages | 14890 |
Keywords | A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT) | ||||
Abstract | Problematic microfossils dominate the palaeontological record between the Great Oxidation Event 2.4 billion years ago (Ga) and the last Palaeoproterozoic iron formations, deposited 500–600 million years later. These fossils are often associated with iron-rich sedimentary rocks, but their affinities, metabolism, and, hence, their contributions to Earth surface oxidation and Fe deposition remain unknown. Here we show that specific microfossil populations of the 1.88 Ga Gunflint Iron Formation contain Fe-silicate and Fe-carbonate nanocrystal concentrations in cell interiors. Fe minerals are absent in/on all organically preserved cell walls. These features are consistent with in vivo intracellular Fe biomineralization, with subsequent in situ recrystallization, but contrast with known patterns of post-mortem Fe mineralization. The Gunflint populations that display relatively large cells (thick-walled spheres, filament-forming rods) and intra-microfossil Fe minerals are consistent with oxygenic photosynthesizers but not with other Fe-mineralizing microorganisms studied so far. Fe biomineralization may have protected oxygenic photosynthesizers against Fe2+ toxicity during the Palaeoproterozoic. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000397129900001 | Publication Date | 2017-03-23 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 2041-1723 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 12.124 | Times cited | 20 | Open Access | OpenAccess |
Notes | We thank J.-P. Cullus (thin sections), G. Spronck and C. Henrist (TEM), M. Cabié and C. Dominici (FIB), S. Bernard and C. Karunakaran (STXM), F. Bourdelle and G. Ji (EELS), P. Recourt (SEM). This study was co-funded by FRFC Grant no. 2.4558.09F (E.J.J.), CNRS-INSU (K.L.), FNRS (K.L.), ERC StG ELiTE Grant no. 308074 (E.J.J.), BELSPO IAP PLANET TOPERS (E.J.J.), NASA Astrobiology Institute (A.H.K.), Conseil Régional du Nord-Pas de Calais+European Regional Development Fund+CNRS-INSU (TEM in Lille), FP7-ESMI no. 262348 (TEM at EMAT Antwerp) and ANR-15-CE31-0003-01 (M6fossils, K.L.). We thank Noah Planavsky and two anonymous reviewers for thorough reviews that helped improve the paper. | Approved | Most recent IF: 12.124 | ||
Call Number | EMAT @ emat @ c:irua:141919 | Serial | 4536 | ||
Permanent link to this record | |||||
Author | Milagres de Oliveira, T.; Albrecht, W.; González-Rubio, G.; Altantzis, T.; Lobato Hoyos, I.P.; Béché, A.; Van Aert, S.; Guerrero-Martínez, A.; Liz-Marzán, L.M.; Bals, S. | ||||
Title | 3D Characterization and Plasmon Mapping of Gold Nanorods Welded by Femtosecond Laser Irradiation | Type | A1 Journal article | ||
Year | 2020 | Publication | Acs Nano | Abbreviated Journal | Acs Nano |
Volume | 14 | Issue | Pages | acsnano.0c02610 | |
Keywords | A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT); Applied Electrochemistry & Catalysis (ELCAT) | ||||
Abstract | Ultrafast laser irradiation can induce morphological and structural changes in plasmonic nanoparticles. Gold nanorods (Au NRs), in particular, can be welded together upon irradiation with femtosecond laser pulses, leading to dimers and trimers through the formation of necks between individual nanorods. We used electron tomography to determine the 3D (atomic) structure at such necks for representative welding geometries and to characterize the induced defects. The spatial distribution of localized surface plasmon modes for different welding configurations was assessed by electron energy loss spectroscopy. Additionally, we were able to directly compare the plasmon line width of single-crystalline and welded Au NRs with single defects at the same resonance energy, thus making a direct link between the structural and plasmonic properties. In this manner, we show that the occurrence of (single) defects results in significant plasmon broadening. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000586793400016 | Publication Date | 2020-08-19 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 1936-0851 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 17.1 | Times cited | 25 | Open Access | OpenAccess |
Notes | This project has received funding from the European Research Council under the European Union's Horizon 2020 research and innovation program (ERC Consolidator Grants #815128 – REALNANO and #770887 – PICOMETRICS). The authors gratefully acknowledge funding from the Research Foundation Flanders (FWO, Belgium) through project funding G.0381.16N and G.0267.18N. W.A. acknowledges an Individual Fellowship funded by the Marie 27 Sklodowska-Curie Actions (MSCA) in Horizon 2020 program (grant 797153, SOPMEN). G.G.-R. acknowledge receipt of FPI Fellowship from the Spanish MINECO. This work has been funded by the Spanish Ministry of Science, Innovation and Universities (MICIU) (Grants RTI2018-095844-B-I00 and MAT2017-86659-R) and the Madrid Regional Government (Grant P2018/NMT-4389). A.B. acknowledges funding from FWO project G093417N and from the European Union's Horizon 2020 research and innovation programme under grant agreement No 823717 – ESTEEM3. L.M.L.-M. acknowledges the Maria de Maeztu Units of Excellence Program from the Spanish State Research Agency (Grant No. MDM-2017-0720); Comunidad de Madrid, P2018/NMT-4389 ; Ministerio de Ciencia, Innovación y Universidades, MAT2017-86659-R RTI2018-095844-B-I00 ; Ministerio de Economía y Competitividad; H2020 Marie Sklodowska-Curie Actions, 797153 ; Fonds Wetenschappelijk Onderzoek, G.0267.18N G.0381.16N G093417N ; H2020 Research Infrastructures, 823717 ; H2020 European Research Council, 770887 815128 ; Agencia Estatal de Investigación, Ministerio de Ciencia, Innovación y Universidades, MDM-2017-0720 ; sygma | Approved | Most recent IF: 17.1; 2020 IF: 13.942 | ||
Call Number | EMAT @ emat @c:irua:172440 | Serial | 6426 | ||
Permanent link to this record | |||||
Author | Altantzis, T.; Lobato, I.; De Backer, A.; Béché, A.; Zhang, Y.; Basak, S.; Porcu, M.; Xu, Q.; Sánchez-Iglesias, A.; Liz-Marzán, L.M.; Van Tendeloo, G.; Van Aert, S.; Bals, S. | ||||
Title | Three-Dimensional Quantification of the Facet Evolution of Pt Nanoparticles in a Variable Gaseous Environment | Type | A1 Journal article | ||
Year | 2019 | Publication | Nano letters | Abbreviated Journal | Nano Lett |
Volume | 19 | Issue | 19 | Pages | 477-481 |
Keywords | A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT) | ||||
Abstract | Pt nanoparticles play an essential role in a wide variety of catalytic reactions. The activity of the particles strongly depends on their three-dimensional (3D) structure and exposed facets, as well as on the reactive environment. High-resolution electron microscopy has often been used to characterize nanoparticle catalysts but unfortunately most observations so far have been either performed in vacuum and/or using conventional (2D) in situ microscopy. The latter however does not provide direct 3D morphological information. We have implemented a quantitative methodology to measure variations of the 3D atomic structure of nanoparticles under the flow of a selected gas. We were thereby able to quantify refaceting of Pt nanoparticles with atomic resolution during various oxidation−reduction cycles. In a H2 environment, a more faceted surface morphology of the particles was observed with {100} and {111} planes being dominant. On the other hand, in O2 the percentage of {100} and {111} facets decreased and a significant increase of higher order facets was found, resulting in a more rounded morphology. This methodology opens up new opportunities toward in situ characterization of catalytic nanoparticles because for the first time it enables one to directly measure 3D morphology variations at the atomic scale in a specific gaseous reaction environment. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000455561300061 | Publication Date | 2019-01-09 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 1530-6984 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 12.712 | Times cited | 82 | Open Access | OpenAccess |
Notes | This work was supported by the European Research Council (Grant 335078 COLOURATOM to S.B. and Grant 770887 PICOMETRICS to S.V.A.). The authors acknowledge funding from the European Commission Grant (EUSMI 731019 to S.B., L.M.L.-M., and Q.X. and MUMMERING 765604 to S.B. and Q.X.). The authors gratefully acknowledge funding from the Research Foundation Flanders (FWO, Belgium) through project fundings (G.0368.15N, G.0369.15N, and G.0267.18N), postdoctoral grants to T.A. and A.D.B, and an FWO [PEGASUS]2 Marie Sklodowska-Curie fellowship to Y.Z. (12U4917N). L.M.L.-M. acknowledges funding from the Spanish Ministerio de Economía y Competitividad (Grant MAT2017-86659-R). We gratefully acknowledge the support of NVIDIA Corporation with the donation of the Titan X Pascal GPU used for this research. ecas_sara Realnano 815128; sygma | Approved | Most recent IF: 12.712 | ||
Call Number | EMAT @ emat @UA @ admin @ c:irua:156390 | Serial | 5150 | ||
Permanent link to this record | |||||
Author | Wolf, D.; Rodriguez, L.A.; Béché, A.; Javon, E.; Serrano, L.; Magen, C.; Gatel, C.; Lubk, A.; Lichte, H.; Bals, S.; Van Tendeloo, G.; Fernández-Pacheco, A.; De Teresa, J.M.; Snoeck, E. | ||||
Title | 3D Magnetic Induction Maps of Nanoscale Materials Revealed by Electron Holographic Tomography | Type | A1 Journal article | ||
Year | 2015 | Publication | Chemistry of materials | Abbreviated Journal | Chem Mater |
Volume | 27 | Issue | 27 | Pages | 6771-6778 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | The investigation of three-dimensional (3D) ferromagnetic nanoscale materials constitutes one of the key research areas of the current magnetism roadmap, and carries great potential to impact areas such as data storage, sensing and biomagnetism. The properties of such nanostructures are closely connected with their 3D magnetic nanostructure, making their determination highly valuable. Up to now, quantitative 3D maps providing both the internal magnetic and electric configuration of the same specimen with high spatial resolution are missing. Here, we demonstrate the quantitative 3D reconstruction of the dominant axial component of the magnetic induction and electrostatic potential within a cobalt nanowire (NW) of 100 nm in diameter with spatial resolution below 10 nanometers by applying electron holographic tomography. The tomogram was obtained using a dedicated TEM sample holder for acquisition, in combination with advanced alignment and tomographic reconstruction routines. The powerful approach presented here is widely applicable to a broad range of 3D magnetic nanostructures and may trigger the progress of novel spintronic non-planar nanodevices. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000362920700037 | Publication Date | 2015-09-08 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0897-4756;1520-5002; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 9.466 | Times cited | 50 | Open Access | OpenAccess |
Notes | This work was supported by the European Union under the Seventh Framework Program under a contract for an Inte-grated Infrastructure Initiative Reference 312483-ESTEEM2. S.B. and A.B. gratefully acknowledge funding by ERC Starting grants number 335078 COLOURATOMS and number 278510 VORTEX. AF-P acknowledges an EPSRC Early Career fellowship and support from the Winton Foundation. E.S., C.G. and L.A. R. acknowledge the French ANR program for support though the project EMMA.; esteem2jra4; ECASJO;; ECAS_Sara; (ROMEO:white; preprint:; postprint:restricted 12 months embargo; pdfversion:cannot); | Approved | Most recent IF: 9.466; 2015 IF: 8.354 | ||
Call Number | c:irua:129180 c:irua:129180 c:irua:129180 | Serial | 3950 | ||
Permanent link to this record | |||||
Author | Vega Ibañez, F.; Béché, A.; Verbeeck, J. | ||||
Title | Can a programmable phase plate serve as an aberration corrector in the transmission electron microscope (TEM)? | Type | A1 Journal article | ||
Year | 2022 | Publication | Microscopy and microanalysis | Abbreviated Journal | Microsc Microanal |
Volume | Issue | Pages | Pii S1431927622012260-10 | ||
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Current progress in programmable electrostatic phase plates raises questions about their usefulness for specific applications. Here, we explore different designs for such phase plates with the specific goal of correcting spherical aberration in the transmission electron microscope (TEM). We numerically investigate whether a phase plate could provide down to 1 angstrom ngstrom spatial resolution on a conventional uncorrected TEM. Different design aspects (fill factor, pixel pattern, symmetry) were evaluated to understand their effect on the electron probe size and current density. Some proposed designs show a probe size () down to 0.66 angstrom, proving that it should be possible to correct spherical aberration well past the 1 angstrom limit using a programmable phase plate consisting of an array of electrostatic phase-shifting elements. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000849975400001 | Publication Date | 2022-09-21 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 1431-9276 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.8 | Times cited | 3 | Open Access | OpenAccess |
Notes | All authors acknowledge funding from the Flemish Research Fund under contract G042820N “Exploring adaptive optics in transmission electron microscopy”. J.V. acknowledges funding from the European Union’s Horizon 2020 Research Infrastructure – Integrating Activities for Advanced Communities under grant agreement No 823717 – ESTEEM3 and from the University of Antwerp through a TOP BOF project.; esteem3reported; esteem3jra | Approved | Most recent IF: 2.8 | ||
Call Number | UA @ admin @ c:irua:190627 | Serial | 7134 | ||
Permanent link to this record | |||||
Author | Esteban, D.A.; Vanrompay, H.; Skorikov, A.; Béché, A.; Verbeeck, J.; Freitag, B.; Bals, S. | ||||
Title | Fast electron low dose tomography for beam sensitive materials | Type | A1 Journal article | ||
Year | 2021 | Publication | Microscopy And Microanalysis | Abbreviated Journal | Microsc Microanal |
Volume | 27 | Issue | S1 | Pages | 2116-2118 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | |||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | Publication Date | 2021-07-30 | ||
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 1431-9276 | ISBN | Additional Links | UA library record | |
Impact Factor | 1.891 | Times cited | Open Access | OpenAccess | |
Notes | Approved | Most recent IF: 1.891 | |||
Call Number | EMAT @ emat @c:irua:183278 | Serial | 6813 | ||
Permanent link to this record | |||||
Author | MacArthur, K.E.; Yankovich, A.B.; Béché, A.; Luysberg, M.; Brown, H.G.; Findlay, S.D.; Heggen, M.; Allen, L.J. | ||||
Title | Optimizing Experimental Conditions for Accurate Quantitative Energy-Dispersive X-ray Analysis of Interfaces at the Atomic Scale | Type | A1 Journal article | ||
Year | 2021 | Publication | Microscopy And Microanalysis | Abbreviated Journal | Microsc Microanal |
Volume | Issue | Pages | 1-15 | ||
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | The invention of silicon drift detectors has resulted in an unprecedented improvement in detection efficiency for energy-dispersive X-ray (EDX) spectroscopy in the scanning transmission electron microscope. The result is numerous beautiful atomic-scale maps, which provide insights into the internal structure of a variety of materials. However, the task still remains to understand exactly where the X-ray signal comes from and how accurately it can be quantified. Unfortunately, when crystals are aligned with a low-order zone axis parallel to the incident beam direction, as is necessary for atomic-resolution imaging, the electron beam channels. When the beam becomes localized in this way, the relationship between the concentration of a particular element and its spectroscopic X-ray signal is generally nonlinear. Here, we discuss the combined effect of both spatial integration and sample tilt for ameliorating the effects of channeling and improving the accuracy of EDX quantification. Both simulations and experimental results will be presented for a perovskite-based oxide interface. We examine how the scattering and spreading of the electron beam can lead to erroneous interpretation of interface compositions, and what approaches can be made to improve our understanding of the underlying atomic structure. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000664532400007 | Publication Date | 2021-04-12 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 1431-9276 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 1.891 | Times cited | Open Access | OpenAccess | |
Notes | The authors would like to thank Jürgen Schubert for helping to supply the sample and valuable discussions on the topic. K. E. MacArthur and M. Heggen acknowledge the Helmholtz Funding agency and the DFG (grant number HE 7192/1-2) for their financial support of this work. L. J. Allen acknowledges the support of the Alexander von Humboldt Foundation. This research was supported under the Discovery Projects funding scheme of the Australian Research Council (Projects DP140102538 and FT190100619). K.E. MacArthur, A.B. Yankovich and A. Béché acknowledge support from the European Union’s Horizon 2020 research innovation program under grant agreement No. 823717 – ESTEEM3. A.B. Yankovich also acknowledges support from the Materials Science Area of Advance at Chalmers and the Swedish Research Council (VR, under grant No: 2020-04986).; esteem3TA; esteem3reported | Approved | Most recent IF: 1.891 | ||
Call Number | EMAT @ emat @c:irua:178129 | Serial | 6760 | ||
Permanent link to this record | |||||
Author | Jannis, D.; Velazco, A.; Béché, A.; Verbeeck, J. | ||||
Title | Reducing electron beam damage through alternative STEM scanning strategies, Part II: Attempt towards an empirical model describing the damage process | Type | A1 Journal article | ||
Year | 2022 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | Issue | Pages | 113568 | ||
Keywords | A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT) | ||||
Abstract | In this second part of a series we attempt to construct an empirical model that can mimick all experimental observations made regarding the role of an alternative interleaved scan pattern in STEM imaging on the beam damage in a specific zeolite sample. We make use of a 2D diffusion model that describes the dissipation of the deposited beam energy in the sequence of probe positions that are visited during the scan pattern. The diffusion process allows for the concept of trying to ‘outrun’ the beam damage by carefully tuning the dwell time and distance between consecutively visited probe positions. We add a non linear function to include a threshold effect and evaluate the accumulated damage in each part of the image as a function of scan pattern details. Together, these ingredients are able to describe qualitatively all aspects of the experimental data and provide us with a model that could guide a further optimisation towards even lower beam damage without lowering the applied electron dose. We deliberately remain vague on what is diffusing here which avoids introducing too many sample specific details. This provides hope that the model can be applied also in sample classes that were not yet studied in such great detail by adjusting higher level parameters: a sample dependent diffusion constant and damage threshold. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000832788000003 | Publication Date | 0000-00-00 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.2 | Times cited | 4 | Open Access | OpenAccess |
Notes | D.J., A.V, A.B. and J.V. acknowledge funding from FWO project G093417N (’Compressed sensing enabling low dose imaging in transmission electron microscopy’) and G042920N (’Coincident event detection for advanced spectroscopy in transmission electron microscopy’). This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 823717 ESTEEM3. The Qu-Ant-EM microscope was partly funded by the Hercules fund from the Flemish Government. J.V. acknowledges funding from GOA project “Solarpaint” of the University of Antwerp .; esteem3reported; esteem3jra; | Approved | Most recent IF: 2.2 | ||
Call Number | EMAT @ emat @c:irua:188535 | Serial | 7071 | ||
Permanent link to this record | |||||
Author | Jannis, D.; Hofer, C.; Gao, C.; Xie, X.; Béché, A.; Pennycook, Tj.; Verbeeck, J. | ||||
Title | Event driven 4D STEM acquisition with a Timepix3 detector: Microsecond dwell time and faster scans for high precision and low dose applications | Type | A1 Journal article | ||
Year | 2022 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 233 | Issue | Pages | 113423 | |
Keywords | A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT) | ||||
Abstract | Four dimensional scanning transmission electron microscopy (4D STEM) records the scattering of electrons in a material in great detail. The benefits offered by 4D STEM are substantial, with the wealth of data it provides facilitating for instance high precision, high electron dose efficiency phase imaging via centre of mass or ptychography based analysis. However the requirement for a 2D image of the scattering to be recorded at each probe position has long placed a severe bottleneck on the speed at which 4D STEM can be performed. Recent advances in camera technology have greatly reduced this bottleneck, with the detection efficiency of direct electron detectors being especially well suited to the technique. However even the fastest frame driven pixelated detectors still significantly limit the scan speed which can be used in 4D STEM, making the resulting data susceptible to drift and hampering its use for low dose beam sensitive applications. Here we report the development of the use of an event driven Timepix3 direct electron camera that allows us to overcome this bottleneck and achieve 4D STEM dwell times down to 100 ns; orders of magnitude faster than what has been possible with frame based readout. We characterize the detector for different acceleration voltages and show that the method is especially well suited for low dose imaging and promises rich datasets without compromising dwell time when compared to conventional STEM imaging. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000734396800003 | Publication Date | 2021-11-13 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.2 | Times cited | 31 | Open Access | OpenAccess |
Notes | This project has received funding from the Euro- pean Union’s Horizon 2020 Research Infrastructure – Integrating Activities for Advanced Communities under grant agreement No 823717 – ESTEEM3. J.V. and A.B. acknowledge funding from FWO project G093417N (‘Compressed sensing enabling low dose imaging in transmission electron microscopy’). J.V. and D.J. ac- knowledge funding from FWO project G042920N ‘Co- incident event detection for advanced spectroscopy in transmission electron microscopy’. We acknowledge funding under the European Union’s Horizon 2020 re- search and innovation programme (J.V. and D.J un- der grant agreement No 101017720, FET-Proactive EBEAM, and C.H., C.G., X.X. and T.J.P. from the Eu- ropean Research Council (ERC) Grant agreement No. 802123-HDEM).; esteem3JRA; esteem3reported | Approved | Most recent IF: 2.2 | ||
Call Number | EMAT @ emat @c:irua:183948 | Serial | 6828 | ||
Permanent link to this record | |||||
Author | Velazco, A.; Béché, A.; Jannis, D.; Verbeeck, J. | ||||
Title | Reducing electron beam damage through alternative STEM scanning strategies, Part I: Experimental findings | Type | A1 Journal article | ||
Year | 2022 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 232 | Issue | Pages | 113398 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | The highly energetic electrons in a transmission electron microscope (TEM) can alter or even completely destroy the structure of samples before sufficient information can be obtained. This is especially problematic in the case of zeolites, organic and biological materials. As this effect depends on both the electron beam and the sample and can involve multiple damage pathways, its study remained difficult and is plagued with irreproducibility issues, circumstantial evidence, rumors, and a general lack of solid data. Here we take on the experimental challenge to investigate the role of the STEM scan pattern on the damage behavior of a commercially available zeolite sample with the clear aim to make our observations as reproducible as possible. We make use of a freely programmable scan engine that gives full control over the tempospatial distribution of the electron probe on the sample and we use its flexibility to obtain multiple repeated experiments under identical conditions comparing the difference in beam damage between a conventional raster scan pattern and a newly proposed interleaved scan pattern that provides exactly the same dose and dose rate and visits exactly the same scan points. We observe a significant difference in beam damage for both patterns with up to 11 % reduction in damage (measured from mass loss). These observations demonstrate without doubt that electron dose, dose rate and acceleration voltage are not the only parameters affecting beam damage in (S)TEM experiments and invite the community to rethink beam damage as an unavoidable consequence of applied electron dose. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000714819200002 | Publication Date | 2021-10-02 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.2 | Times cited | 18 | Open Access | OpenAccess |
Notes | A.V., D.J., A.B. and J.V. acknowledge funding from FWO project G093417N (’Compressed sensing enabling low dose imaging in transmission electron microscopy’) and G042920N (’Coincident event detection for advanced spectroscopy in transmission electron microscopy’). This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 823717 ESTEEM3. The Qu-Ant-EM microscope was partly funded by the Hercules fund from the Flemish Government. J.V. acknowledges funding from GOA project “Solarpaint” of the University of Antwerp.; JRA; reported | Approved | Most recent IF: 2.2 | ||
Call Number | EMAT @ emat @c:irua:183282 | Serial | 6818 | ||
Permanent link to this record | |||||
Author | Vanrompay, H.; Skorikov, A.; Bladt, E.; Béché, A.; Freitag, B.; Verbeeck, J.; Bals, S. | ||||
Title | Fast versus conventional HAADF-STEM tomography of nanoparticles: advantages and challenges | Type | A1 Journal article | ||
Year | 2021 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 221 | Issue | Pages | 113191 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | HAADF-STEM tomography is a widely used experimental technique for analyzing nanometer-scale crystalline structures of a large variety of materials in three dimensions. Unfortunately, the acquisition of conventional HAADF-STEM tilt series can easily take up one hour or more, depending on the complexity of the experiment. It is therefore far from straightforward to investigate samples that do not withstand long acquisition or to acquire large amounts of tilt series during a single TEM experiment. The latter would lead to the ability to obtain statistically meaningful 3D data, or to perform in situ 3D characterizations with a much shorter time resolution. Various HAADF-STEM acquisition strategies have been proposed to accelerate the tomographic acquisition and reduce the required electron dose. These methods include tilting the holder continuously while acquiring a projection “movie” and a hybrid, incremental, methodology which combines the benefits of the conventional and continuous technique. However, until now an experimental evaluation has been lacking. In this paper, the different acquisition strategies will be experimentally compared in terms of speed, resolution and electron dose. This evaluation will be performed based on experimental tilt series acquired for various metallic nanoparticles with different shapes and sizes. We discuss the data processing involved with the fast HAADF-STEM tilt series and provide a general guideline when which acquisition strategy should be preferentially used. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000612539600003 | Publication Date | 2020-12-08 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 15 | Open Access | OpenAccess |
Notes | We acknowledge Prof. Luis M. Liz-Marzán and co-workers of the Bionanoplasmonics Laboratory, CIC biomaGUNE, Spain for providing the Au@Ag nanoparticles, Prof. Sara. E. Skrabalak and co-workers of Indiana University, United States for the provision of the Au octopods and Prof. Teri W. Odom of Northwestern University, United States for the provision of the Au nanostars. H.V. acknowledges financial support by the Research Foundation Flanders (FWO grant 1S32617N). S.B acknowledges financial support by the Research Foundation Flanders (FWO grant G.0381.16N). This project received funding as well from the European Union’s Horizon 2020 research and innovation program under grant agreement No 731019 (EUSMI) and No 815128 (REALNANO). The authors acknowledge the entire EMAT technical staff for their support.; sygma | Approved | Most recent IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:174551 | Serial | 6660 | ||
Permanent link to this record | |||||
Author | Prabhakara, V.; Jannis, D.; Guzzinati, G.; Béché, A.; Bender, H.; Verbeeck, J. | ||||
Title | HAADF-STEM block-scanning strategy for local measurement of strain at the nanoscale | Type | A1 Journal article | ||
Year | 2020 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 219 | Issue | Pages | 113099 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Lattice strain measurement of nanoscale semiconductor devices is crucial for the semiconductor industry as strain substantially improves the electrical performance of transistors. High resolution scanning transmission electron microscopy (HR-STEM) imaging is an excellent tool that provides spatial resolution at the atomic scale and strain information by applying Geometric Phase Analysis or image fitting procedures. However, HR-STEM images regularly suffer from scanning distortions and sample drift during image acquisition. In this paper, we propose a new scanning strategy that drastically reduces artefacts due to drift and scanning distortion, along with extending the field of view. It consists of the acquisition of a series of independent small subimages containing an atomic resolution image of the local lattice. All subimages are then analysed individually for strain by fitting a nonlinear model to the lattice images. The method allows flexible tuning of spatial resolution and the field of view within the limits of the dynamic range of the scan engine while maintaining atomic resolution sampling within the subimages. The obtained experimental strain maps are quantitatively benchmarked against the Bessel diffraction technique. We demonstrate that the proposed scanning strategy approaches the performance of the diffraction technique while having the advantage that it does not require specialized diffraction cameras. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000594768500006 | Publication Date | 2020-09-01 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.2 | Times cited | 4 | Open Access | OpenAccess |
Notes | A.B. D.J. and J.V. acknowledge funding through FWO project G093417N ('Compressed sensing enabling low dose imaging in transmission electron microscopy') from the Flanders Research Fund. J.V acknowledges funding from the European Union's Horizon 2020 research and innovation programme under grant agreement No 823717 – ESTEEM3. The Qu-Ant-EM microscope and the direct electron detector used in the diffraction experiments was partly funded by the Hercules fund from the Flemish Government. This project has received funding from the GOA project “Solarpaint” of the University of Antwerp. GG acknowledges support from a postdoctoral fellowship grant from the Fonds Wetenschappelijk Onderzoek – Vlaanderen (FWO). Special thanks to Dr. Thomas Nuytten, Prof. Dr. Wilfried Vandervorst, Dr. Paola Favia, Dr. Olivier Richard from IMEC, Leuven and Prof. Dr. Sara Bals from EMAT, Antwerp for their continuous support and collaboration with the project and to the IMEC processing group for the device fabrication. | Approved | Most recent IF: 2.2; 2020 IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:172485 | Serial | 6404 | ||
Permanent link to this record | |||||
Author | Velazco, A.; Nord, M.; Béché, A.; Verbeeck, J. | ||||
Title | Evaluation of different rectangular scan strategies for STEM imaging | Type | A1 Journal article | ||
Year | 2020 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | Issue | Pages | 113021 | ||
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | STEM imaging is typically performed by raster scanning a focused electron probe over a sample. Here we investigate and compare three different scan patterns, making use of a programmable scan engine that allows to arbitrarily set the sequence of probe positions that are consecutively visited on the sample. We compare the typical raster scan with a so-called ‘snake’ pattern where the scan direction is reversed after each row and a novel Hilbert scan pattern that changes scan direction rapidly and provides an homogeneous treatment of both scan directions. We experimentally evaluate the imaging performance on a single crystal test sample by varying dwell time and evaluating behaviour with respect to sample drift. We demonstrate the ability of the Hilbert scan pattern to more faithfully represent the high frequency content of the image in the presence of sample drift. It is also shown that Hilbert scanning provides reduced bias when measuring lattice parameters from the obtained scanned images while maintaining similar precision in both scan directions which is especially important when e.g. performing strain analysis. Compared to raster scanning with flyback correction, both snake and Hilbert scanning benefit from dose reduction as only small probe movement steps occur. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000544042800007 | Publication Date | 2020-05-21 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.2 | Times cited | 13 | Open Access | OpenAccess |
Notes | A.V., A.B. and J.V. acknowledge funding through FWO project G093417N ('Compressed sensing enabling low dose imaging in transmission electron microscopy') from the Flanders Research Fund. M.N. received support for this work from the European Union's Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement No 838001. J.V acknowledges funding from the European Union's Horizon 2020 research and innovation programme under grant agreement No 823717 – ESTEEM3. | Approved | Most recent IF: 2.2; 2020 IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:169225 | Serial | 6369 | ||
Permanent link to this record | |||||
Author | Müller-Caspary, K.; Krause, F.F.; Winkler, F.; Béché, A.; Verbeeck, J.; Van Aert, S.; Rosenauer, A. | ||||
Title | Comparison of first moment STEM with conventional differential phase contrast and the dependence on electron dose | Type | A1 Journal article | ||
Year | 2019 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 203 | Issue | 203 | Pages | 95-104 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | This study addresses the comparison of scanning transmission electron microscopy (STEM) measurements of momentum transfers using the first moment approach and the established method that uses segmented annular detectors. Using an ultrafast pixelated detector to acquire four-dimensional, momentum-resolved STEM signals, both the first moment calculation and the calculation of the differential phase contrast (DPC) signals are done for the same experimental data. In particular, we investigate the ability to correct the segment-based signal to yield a suitable approximation of the first moment for cases beyond the weak phase object approximation. It is found that the measurement of momentum transfers using segmented detectors can approach the first moment measurement as close as 0.13 h/nm in terms of a root mean square (rms) difference in 10 nm thick SrTiO3 for a detector with 16 segments. This amounts to 35% of the rms of the momentum transfers. In addition, we present a statistical analysis of the precision of first moment STEM as a function of dose. For typical experimental settings with recent hardware such as a Medipix3 Merlin camera attached to a probe-corrected STEM, we find that the precision of the measurement of momentum transfers stagnates above certain doses. This means that other instabilities such as specimen drift or scan noise have to be taken into account seriously for measurements that target, e.g., the detection of bonding effects in the charge density. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000465021000013 | Publication Date | 2018-12-30 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 25 | Open Access | OpenAccess |
Notes | ; The direct electron detector (Medipix3 Merlin) was funded by the Hercules fund from the Flemish Government. K. Muller-Caspary acknowledges funding from the Initiative and Network Fund of the Helmholtz Association within the framework of the Helmholtz Young Investigator Group moreSTEM (VH-NG-1317) at Forschungszentrum Julich, Germany. F. F. Krause acknowledges funding from the Central Research Development Fund of the University of Bremen, Germany. This project has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (Grant Agreement No. 770887). The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) and the Research Fund of the University of Antwerp. ; | Approved | Most recent IF: 2.843 | ||
Call Number | UA @ admin @ c:irua:160213 | Serial | 5242 | ||
Permanent link to this record | |||||
Author | Verbeeck, J.; Béché, A.; Müller-Caspary, K.; Guzzinati, G.; Luong, M.A.; Den Hertog, M. | ||||
Title | Demonstration of a 2 × 2 programmable phase plate for electrons | Type | A1 Journal article | ||
Year | 2018 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 190 | Issue | Pages | 58-65 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | First results on the experimental realisation of a 2 × 2 programmable phase plate for electrons are presented. The design consists of an array of electrostatic elements that influence the phase of electron waves passing through 4 separately controllable aperture holes. This functionality is demonstrated in a conventional transmission electron microscope operating at 300 kV and results are in very close agreement with theoretical predictions. The dynamic creation of a set of electron probes with different phase symmetry is demonstrated, thereby bringing adaptive optics in TEM one step closer to reality. The limitations of the current design and how to overcome these in the future are discussed. Simulations show how further evolved versions of the current proof of concept might open new and exciting application prospects for beam shaping and aberration correction. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000432868800007 | Publication Date | 2018-04-18 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 73 | Open Access | Not_Open_Access: Available from 19.04.2020 |
Notes | J.V. and A.B. acknowledge funding from the Fund for Scientific Research Flanders FWO project G093417N and the European Research Council under the 7th Framework Program (FP7), ERC Starting Grant 278510 VORTEX and ERC proof of concept project DLV-789598 ADAPTEM. The Qu-Ant-EM microscope used in this work was partly funded by the Hercules fund from the Flemish Government. MdH acknowledges financial support from the ANRCOSMOS (ANR-12-JS10-0002). MdH and ML acknowledge funding from the Laboratoire d’excellence LANEF in Grenoble (ANR-10-LABX-51-01). | Approved | Most recent IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:150459UA @ admin @ c:irua:150459 | Serial | 4920 | ||
Permanent link to this record | |||||
Author | Gauquelin, N.; van den Bos, K.H.W.; Béché, A.; Krause, F.F.; Lobato, I.; Lazar, S.; Rosenauer, A.; Van Aert, S.; Verbeeck, J. | ||||
Title | Determining oxygen relaxations at an interface: A comparative study between transmission electron microscopy techniques | Type | A1 Journal article | ||
Year | 2017 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 181 | Issue | 181 | Pages | 178-190 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Nowadays, aberration corrected transmission electron microscopy (TEM) is a popular method to characterise nanomaterials at the atomic scale. Here, atomically resolved images of nanomaterials are acquired, where the contrast depends on the illumination, imaging and detector conditions of the microscope. Visualization of light elements is possible when using low angle annular dark field (LAADF) STEM, annular bright field (ABF) STEM, integrated differential phase contrast (iDPC) STEM, negative spherical aberration imaging (NCSI) and imaging STEM (ISTEM). In this work, images of a NdGaO3-La0.67Sr0.33MnO3 (NGO-LSMO) interface are quantitatively evaluated by using statistical parameter estimation theory. For imaging light elements, all techniques are providing reliable results, while the techniques based on interference contrast, NCSI and ISTEM, are less robust in terms of accuracy for extracting heavy column locations. In term of precision, sample drift and scan distortions mainly limits the STEM based techniques as compared to NCSI. Post processing techniques can, however, partially compensate for this. In order to provide an outlook to the future, simulated images of NGO, in which the unavoidable presence of Poisson noise is taken into account, are used to determine the ultimate precision. In this future counting noise limited scenario, NCSI and ISTEM imaging will provide more precise values as compared to the other techniques, which can be related to the mechanisms behind the image recording. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000411170800022 | Publication Date | 2017-06-03 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 34 | Open Access | OpenAccess |
Notes | The authors acknowledge financial support from Flanders (FWO, Belgium) through project fundings (G.0044.13N, G.0374.13N, G.0368.15N, G.0369.15N), and by a Ph.D. grant to K.H.W.v.d.B. The Qu-Ant-EM microscope used for this study was partly funded by the Hercules fund from the Flemish Government. A.B. and N.G. acknowledge the EUROTAPES project (FP7-NMP.2011.2.2-1 Grant no.280432) which partly funded this study. N.G., A.B. and J.V. acknowledge funding from the European Research Council under the 7th Framework Program (FP7), ERC Starting Grant 278510 VORTEX. The research leading to these results has received funding from the Deutsche Forschungsgemeinschaft under Contract No. RO 2057/4-2 and the European Union Seventh Framework Programme under Grant Agreement 312483 – ESTEEM2. We thank Prof. G. Koster from the University of Twente for kindly providing us with the LSMO-NGO test sample. | Approved | Most recent IF: 2.843 | ||
Call Number | EMAT @ emat @ c:irua:144435UA @ admin @ c:irua:144435 | Serial | 4620 | ||
Permanent link to this record | |||||
Author | van den Bos, K.H.W.; Krause, F.F.; Béché, A.; Verbeeck, J.; Rosenauer, A.; Van Aert, S. | ||||
Title | Locating light and heavy atomic column positions with picometer precision using ISTEM | Type | A1 Journal article | ||
Year | 2016 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 172 | Issue | 172 | Pages | 75-81 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Recently, imaging scanning transmission electron microscopy (ISTEM) has been proposed as a promising new technique combining the advantages of conventional TEM (CTEM) and STEM [1]. The ability to visualize light and heavy elements together makes it a particularly interesting new, spatially incoherent imaging mode. Here, we evaluate this technique in term of precision with which atomic column locations can be measured. By using statistical parameter estimation theory, we will show that these locations can be accurately measured with a precision in the picometer range. Furthermore, a quantitative comparison is made with HAADF STEM imaging to investigate the advantages of ISTEM. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000390600200009 | Publication Date | 2016-10-09 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 8 | Open Access | |
Notes | The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through project fundings (G.0374.13N, G.0368.15N, G.0369.15N), and by a Ph.D. grant to K.H.W. van den Bos. The research leading to these results has received funding from the Deutsche Forschungsgemeinschaft under Contract No. RO 2057/4-2 and the European Union Seventh Framework Programme under Grant Agreement 312483 – ESTEEM2. We thank Prof. G. Koster from the University of Twente for kindly providing us with the PbTiO3 test sample. | Approved | Most recent IF: 2.843 | ||
Call Number | EMAT @ emat @ c:irua:136109UA @ admin @ c:irua:136109 | Serial | 4288 | ||
Permanent link to this record | |||||
Author | Béché, A.; Juchtmans, R.; Verbeeck, J. | ||||
Title | Efficient creation of electron vortex beams for high resolution STEM imaging | Type | A1 Journal article | ||
Year | 2017 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 178 | Issue | 178 | Pages | 12-19 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | The recent discovery of electron vortex beams carrying quantised angular momentum in the TEM has led to an active field of research, exploring a variety of potential applications including the possibility of mapping magnetic states at the atomic scale. A prerequisite for this is the availability of atomic sized electron vortex beams at high beam current and mode purity. In this paper we present recent progress showing that by making use of the Aharonov-Bohm effect near the tip of a long single domain ferromagnetic Nickel needle, a very efficient aperture for the production of electron vortex beams can be realised. The aperture transmits more than 99% of all electrons and provides a vortex mode purity of up to 92%. Placing this aperture in the condenser plane of a state of the art Cs corrected microscope allows us to demonstrate atomic resolution HAADF STEM images with spatial resolution better than 1 Angstrom, in agreement with theoretical expectations and only slightly inferior to the performance of a non-vortex probe on the same instrument. | ||||
Address | EMAT, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium | ||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | English | Wos | 000403862900003 | Publication Date | 2016-05-10 |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 30 | Open Access | OpenAccess |
Notes | A.B. and J.V. acknowledge funding from the European Research Council under the 7th Framework Program (FP7), ERC Starting Grant No. 278510 VORTEX. J.V. acknowledges funding from FWO project G.0044.13N ('Charge ordering').; ECASJO_; | Approved | Most recent IF: 2.843 | ||
Call Number | c:irua:134085 c:irua:134085UA @ admin @ c:irua:134085 | Serial | 4094 | ||
Permanent link to this record | |||||
Author | Muller-Caspary, K.; Krause, F.F.; Grieb, T.; Loffler, S.; Schowalter, M.; Béché, A.; Galioit, V.; Marquardt, D.; Zweck, J.; Schattschneider, P.; Verbeeck, J.; Rosenauer, A. | ||||
Title | Measurement of atomic electric fields and charge densities from average momentum transfers using scanning transmission electron microscopy | Type | A1 Journal article | ||
Year | 2016 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 178 | Issue | 178 | Pages | 62-80 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | This study sheds light on the prerequisites, possibilities, limitations and interpretation of high-resolution differential phase contrast (DPC) imaging in scanning transmission electron microscopy (STEM). We draw particular attention to the well-established DPC technique based on segmented annular detectors and its relation to recent developments based on pixelated detectors. These employ the expectation value of the momentum transfer as a reliable measure of the angular deflection of the STEM beam induced by an electric field in the specimen. The influence of scattering and propagation of electrons within the specimen is initially discussed separately and then treated in terms of a two-state channeling theory. A detailed simulation study of GaN is presented as a function of specimen thickness and bonding. It is found that bonding effects are rather detectable implicitly, e.g., by characteristics of the momentum flux in areas between the atoms than by directly mapping electric fields and charge densities. For strontium titanate, experimental charge densities are compared with simulations and discussed with respect to experimental artifacts such as scan noise. Finally, we consider practical issues such as figures of merit for spatial and momentum resolution, minimum electron dose, and the mapping of larger-scale, built-in electric fields by virtue of data averaged over a crystal unit cell. We find that the latter is possible for crystals with an inversion center. Concerning the optimal detector design, this study indicates that a sampling of 5mrad per pixel is sufficient in typical applications, corresponding to approximately 10x10 available pixels. | ||||
Address | Institut fur Festkr perphysik, Universitat Bremen, Otto-Hahn-Allee 1, 28359 Bremen, Germany | ||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | English | Wos | 000403862900009 | Publication Date | 2016-05-12 |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 93 | Open Access | |
Notes | K.M.-C. acknowledges support from the Deutsche Forschungsgemeinschaft (DFG) under contract MU3660/1-1. This work was further supported by the DFG under contract RO2057/4-2 and O2057/11-1. J.V. and A.B. acknowledge funding from the European Research Council (ERC) under the 7th Framework Program (FP7), and ERC Starting Grant No. 278510-VORTEX. Experimental results are obtained on the Qu-Ant-EM microscope partly funded by the Hercules fund from the Flemish government. J.V. also acknowledges funding through a GOA project “Solarpaint” of the University of Antwerp. SL and PS acknowledge financial support by the Austrian Science Fund (FWF) under grants No. I543-N20 and J3732-N27. ECASJO_; | Approved | Most recent IF: 2.843 | ||
Call Number | c:irua:134125UA @ admin @ c:irua:134125 | Serial | 4098 | ||
Permanent link to this record | |||||
Author | Martinez, G.T.; Jones, L.; de Backer, A.; Béché, A.; Verbeeck, J.; Van Aert, S.; Nellist, P.D. | ||||
Title | Quantitative STEM normalisation : the importance of the electron flux | Type | A1 Journal article | ||
Year | 2015 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 159 | Issue | 159 | Pages | 46-58 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Annular dark-field (ADF) scanning transmission electron microscopy (STEM) has become widely used in quantitative studies based on the opportunity to directly compare experimental and simulated images. This comparison merely requires the experimental data to be normalised and expressed in units of fractional beam-current. However, inhomogeneities in the response of electron detectors can complicate this normalisation. The quantification procedure becomes both experiment and instrument specific, requiring new simulations for the particular response of each instrument's detector, and for every camera-length used. This not only impedes the comparison between different instruments and research groups, but can also be computationally very time consuming. Furthermore, not all image simulation methods allow for the inclusion of an inhomogeneous detector response. In this work, we propose an alternative method for normalising experimental data in order to compare these with simulations that consider a homogeneous detector response. To achieve this, we determine the electron flux distribution reaching the detector by means of a camera-length series or a so-called atomic column cross-section averaged convergent beam electron diffraction (XSACBED) pattern. The result is then used to determine the relative weighting of the detector response. Here we show that the results obtained by this new electron flux weighted (EFW) method are comparable to the currently used method, while considerably simplifying the needed simulation libraries. The proposed method also allows one to obtain a metric that describes the quality of the detector response in comparison with the ideal detector response. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000366220000006 | Publication Date | 2015-08-01 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 27 | Open Access | |
Notes | 246791 Countatoms; 278510 Vortex; 312483 Esteem2; Fwo G036815; G036915; G037413; G004413; esteem2ta ECASJO; | Approved | Most recent IF: 2.843; 2015 IF: 2.436 | ||
Call Number | c:irua:127293 c:irua:127293UA @ admin @ c:irua:127293 | Serial | 2762 | ||
Permanent link to this record | |||||
Author | de Backer, A.; Martinez, G.T.; MacArthur, K.E.; Jones, L.; Béché, A.; Nellist, P.D.; Van Aert, S. | ||||
Title | Dose limited reliability of quantitative annular dark field scanning transmission electron microscopy for nano-particle atom-counting | Type | A1 Journal article | ||
Year | 2015 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 151 | Issue | 151 | Pages | 56-61 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Quantitative annular dark field scanning transmission electron microscopy (ADF STEM) has become a powerful technique to characterise nano-particles on an atomic scale. Because of their limited size and beam sensitivity, the atomic structure of such particles may become extremely challenging to determine. Therefore keeping the incoming electron dose to a minimum is important. However, this may reduce the reliability of quantitative ADF STEM which will here be demonstrated for nano-particle atom-counting. Based on experimental ADF STEM images of a real industrial catalyst, we discuss the limits for counting the number of atoms in a projected atomic column with single atom sensitivity. We diagnose these limits by combining a thorough statistical method and detailed image simulations. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000351237800008 | Publication Date | 2014-12-03 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 29 | Open Access | |
Notes | 312483 Esteem2; 278510 Vortex; Fwo G039311; G006410; G037413; esteem2ta; ECASJO; | Approved | Most recent IF: 2.843; 2015 IF: 2.436 | ||
Call Number | c:irua:123927 c:irua:123927 | Serial | 753 | ||
Permanent link to this record | |||||
Author | Guzzinati, G.; Clark, L.; Béché, A.; Juchtmans, R.; Van Boxem, R.; Mazilu, M.; Verbeeck, J. | ||||
Title | Prospects for versatile phase manipulation in the TEM : beyond aberration correction | Type | A1 Journal article | ||
Year | 2015 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 151 | Issue | 151 | Pages | 85-93 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | In this paper we explore the desirability of a transmission electron microscope in which the phase of the electron wave can be freely controlled. We discuss different existing methods to manipulate the phase of the electron wave and their limitations. We show how with the help of current techniques the electron wave can already be crafted into specific classes of waves each having their own peculiar properties. Assuming a versatile phase modulation device is feasible, we explore possible benefits and methods that could come into existence borrowing from light optics where the so-called spatial light modulators provide programmable phase plates for quite some time now. We demonstrate that a fully controllable phase plate building on Harald Rose׳s legacy in aberration correction and electron optics in general would open an exciting field of research and applications. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000351237800012 | Publication Date | 2014-10-22 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 19 | Open Access | |
Notes | 278510 Vortex; Fwo; 312483 Esteem2; esteem2jra2; esteem2jra3 ECASJO_; | Approved | Most recent IF: 2.843; 2015 IF: 2.436 | ||
Call Number | c:irua:121405 c:irua:121405UA @ admin @ c:irua:121405 | Serial | 2731 | ||
Permanent link to this record | |||||
Author | Bliokh, K.Y.; Ivanov, I.P.; Guzzinati, G.; Clark, L.; Van Boxem, R.; Béché, A.; Juchtmans, R.; Alonso, M.A.; Schattschneider, P.; Nori, F.; Verbeeck, J. | ||||
Title | Theory and applications of free-electron vortex states | Type | A1 Journal article | ||
Year | 2017 | Publication | Physics reports | Abbreviated Journal | Phys Rep |
Volume | 690 | Issue | 690 | Pages | 1-70 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Both classical and quantum waves can form vortices: with helical phase fronts and azimuthal current densities. These features determine the intrinsic orbital angular momentum carried by localized vortex states. In the past 25 years, optical vortex beams have become an inherent part of modern optics, with many remarkable achievements and applications. In the past decade, it has been realized and demonstrated that such vortex beams or wavepackets can also appear in free electron waves, in particular, in electron microscopy. Interest in free-electron vortex states quickly spread over different areas of physics: from basic aspects of quantum mechanics, via applications for fine probing of matter (including individual atoms), to high-energy particle collision and radiation processes. Here we provide a comprehensive review of theoretical and experimental studies in this emerging field of research. We describe the main properties of electron vortex states, experimental achievements and possible applications within transmission electron microscopy, as well as the possible role of vortex electrons in relativistic and high-energy processes. We aim to provide a balanced description including a pedagogical introduction, solid theoretical basis, and a wide range of practical details. Special attention is paid to translate theoretical insights into suggestions for future experiments, in electron microscopy and beyond, in any situation where free electrons occur. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000406169900001 | Publication Date | 2017-05-29 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0370-1573 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 17.425 | Times cited | 210 | Open Access | OpenAccess |
Notes | AFOSR, FA9550-14-1-0040 ; CREST, JPMJCR1676 ; Portuguese Fundação para a Ciência e a Tecnologia (FCT), IF/00989/2014/CP1214/CT0004 ; Austrian Science Fund, I543-N20 ; ERC, 278510 VORTEX ; We acknowledge discussions with Mark R. Dennis and Andrei Afanasev. This work was supported by the RIKEN Interdisciplinary Theoretical Science Research Group (iTHES) Project, the Multi-University Research Initiative (MURI) Center for Dynamic Magneto-Optics via the Air Force Office of Scientific Research (AFOSR) (Grant No. FA9550-14-1-0040), Grant-in-Aid for Scientific Research (A), Core Research for Evolutionary Science and Technology (CREST), the John Templeton Foundation, the Australian Research Council, the Portuguese Funda¸c˜ao para a Ciˆencia e a Tecnologia (FCT) (contract IF/00989/2014/CP1214/CT0004 under the IF2014 Program), contracts UID/FIS/00777/2013 and CERN/FIS-NUC/0010/2015 (partially funded through POCTI, COMPETE, QREN, and the European Union), Austrian Science Fund Grant No. I543-N20, the European Research Council under the 7th Framework Program (FP7) (ERC Starting Grant No. 278510 VORTEX), and FWO PhD Fellowship grants (Aspirant Fonds Wetenschappelijk OnderzoekVlaanderen). | Approved | Most recent IF: 17.425 | ||
Call Number | EMAT @ emat @ c:irua:143262 | Serial | 4574 | ||
Permanent link to this record | |||||
Author | Cooper, D.; Denneulin, T.; Bernier, N.; Béché, A.; Rouvière, J.-L. | ||||
Title | Strain mapping of semiconductor specimens with nm-scale resolution in a transmission electron microscope | Type | A1 Journal article | ||
Year | 2016 | Publication | Micron | Abbreviated Journal | Micron |
Volume | 80 | Issue | 80 | Pages | 145-165 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | The last few years have seen a great deal of progress in the development of transmission electron microscopy based techniques for strain mapping. New techniques have appeared such as dark field electron holography and nanobeam diffraction and better known ones such as geometrical phase analysis have been improved by using aberration corrected ultra-stable modern electron microscopes. In this paper we apply dark field electron holography, the geometrical phase analysis of high angle annular dark field scanning transmission electron microscopy images, nanobeam diffraction and precession diffraction, all performed at the state-of-the-art to five different types of semiconductor samples. These include a simple calibration structure comprising 10-nm-thick SiGe layers to benchmark the techniques. A SiGe recessed source and drain device has been examined in order to test their capabilities on 2D structures. Devices that have been strained using a nitride stressor have been examined to test the sensitivity of the different techniques when applied to systems containing low values of deformation. To test the techniques on modern semiconductors, an electrically tested device grown on a SOI wafer has been examined. Finally a GaN/AlN superlattice was tested in order to assess the different methods of measuring deformation on specimens that do not have a perfect crystalline structure. The different deformation mapping techniques have been compared to one another and the strengths and weaknesses of each are discussed. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Oxford | Editor | ||
Language | Wos | 000366770100018 | Publication Date | 2015-09-15 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0968-4328 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 1.98 | Times cited | 50 | Open Access | |
Notes | Approved | Most recent IF: 1.98 | |||
Call Number | UA @ lucian @ c:irua:136446 | Serial | 4401 | ||
Permanent link to this record | |||||
Author | Béché, A.; Winkler, R.; Plank, H.; Hofer, F.; Verbeeck, J. | ||||
Title | Focused electron beam induced deposition as a tool to create electron vortices | Type | A1 Journal article | ||
Year | 2015 | Publication | Micron | Abbreviated Journal | Micron |
Volume | 80 | Issue | 80 | Pages | 34-38 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Focused electron beam induced deposition (FEBID) is a microscopic technique that allows geometrically controlled material deposition with very high spatial resolution. This technique was used to create a spiral aperture capable of generating electron vortex beams in a transmission electron microscope (TEM). The vortex was then fully characterized using different TEM techniques, estimating the average orbital angular momentum to be approximately 0.8variant Planck's over 2pi per electron with almost 60% of the beam ending up in the l=1 state. | ||||
Address | EMAT, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium | ||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | English | Wos | 000366770100006 | Publication Date | 2015-09-12 |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0968-4328; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 1.98 | Times cited | 21 | Open Access | |
Notes | A.B and J.V. acknowledge funding from the European Research Council under the 7th Framework Program (FP7), ERC Starting Grant No. 278510 VORTEX. J.V., R.W., H.P. and F.H. acknowledge financial support from the European Union under the 7th Framework Program (FP7) under a contract for an Integrated Infrastructure Initiative (Reference No. 312483 ESTEEM2). R.W and H.P also acknowledge financial support by the COST action CELINA (Nr. CM1301) and the EUROSTARS project TRIPLE-S (Nr. E!8213). The Qu-Ant-EM microscope was partly funded by the Hercules fund from the Flemish Government.; esteem2jra3 ECASJO; | Approved | Most recent IF: 1.98; 2015 IF: 1.988 | ||
Call Number | c:irua:129203 c:irua:129203UA @ admin @ c:irua:129203 | Serial | 3946 | ||
Permanent link to this record | |||||
Author | Verbeeck, J.; Guzzinati, G.; Clark, L.; Juchtmans, R.; Van Boxem, R.; Tian, H.; Béché, A.; Lubk, A.; Van Tendeloo, G. | ||||
Title | Shaping electron beams for the generation of innovative measurements in the (S)TEM | Type | A1 Journal article | ||
Year | 2014 | Publication | Comptes rendus : physique | Abbreviated Journal | Cr Phys |
Volume | 15 | Issue | 2-3 | Pages | 190-199 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | In TEM, a typical goal consists of making a small electron probe in the sample plane in order to obtain high spatial resolution in scanning transmission electron microscopy. In order to do so, the phase of the electron wave is corrected to resemble a spherical wave compensating for aberrations in the magnetic lenses. In this contribution, we discuss the advantage of changing the phase of an electron wave in a specific way in order to obtain fundamentally different electron probes opening up new applications in the (S)TEM. We focus on electron vortex states as a specific family of waves with an azimuthal phase signature and discuss their properties, production and applications. The concepts presented here are rather general and also different classes of probes can be obtained in a similar fashion, showing that electron probes can be tuned to optimize a specific measurement or interaction. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Paris | Editor | ||
Language | Wos | 000334013600009 | Publication Date | 2014-02-01 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 1631-0705; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.048 | Times cited | 22 | Open Access | |
Notes | Vortex ECASJO_; | Approved | Most recent IF: 2.048; 2014 IF: 2.035 | ||
Call Number | UA @ lucian @ c:irua:116946UA @ admin @ c:irua:116946 | Serial | 2992 | ||
Permanent link to this record | |||||
Author | Idrissi, H.; Béché, A.; Gauquelin, N.; Ul-Haq, I.; Bollinger, C.; Demouchy, S.; Verbeeck, J.; Pardoen, T.; Schryvers, D.; Cordier, P. | ||||
Title | On the formation mechanisms of intragranular shear bands in olivine by stress-induced amorphization | Type | A1 Journal article | ||
Year | 2022 | Publication | Acta materialia | Abbreviated Journal | Acta Mater |
Volume | 239 | Issue | Pages | 118247-118249 | |
Keywords | A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT) | ||||
Abstract | Intragranular amorphization shear lamellae are found in deformed olivine aggregates. The detailed trans-mission electron microscopy analysis of intragranular lamella arrested in the core of a grain provides novel information on the amorphization mechanism. The deformation field is complex and heteroge-neous, corresponding to a shear crack type instability involving mode I, II and III loading components. The formation and propagation of the amorphous lamella is accompanied by the formation of crystal defects ahead of the tip. These defects are geometrically necessary [001] dislocations, characteristics of high-stress deformation in olivine, and rotational nanodomains which are tentatively interpreted as disclinations. We show that these defects play an important role in dictating the path followed by the amorphous lamella. Stress-induced amorphization in olivine would thus result from a direct crystal-to -amorphous transformation associated with a shear instability and not from a mechanical destabilization due to the accumulation of high number of defects from an intense preliminary deformation. The pref-erential alignment of some lamellae along (010) is a proof of the lower ultimate mechanical strength of these planes.(c) 2022 The Authors. Published by Elsevier Ltd on behalf of Acta Materialia Inc. This is an open access article under the CC BY license ( http://creativecommons.org/licenses/by/4.0/ ) | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000861076600004 | Publication Date | 2022-08-05 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 1359-6454 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 9.4 | Times cited | 5 | Open Access | OpenAccess |
Notes | The QuanTEM microscope was partially funded by the Flemish government. The K2 camera was funded by FWO Hercules fund G0H4316N 'Direct electron detector for soft matter TEM'. A. Beche acknowledges funding from FWO project G093417N ('Compressed sensing enabling low dose imaging in transmission electron microscopy'). H. Idrissi is mandated by the Belgian National Fund for Scientific Research (FSR-FNRS). This work was supported by the FNRS under Grant PDR – T011322F and by the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme under grant agreement No 787,198 Time Man. J-L Rouviere is acknowledged for his support with the GPA softawre. | Approved | Most recent IF: 9.4 | ||
Call Number | UA @ admin @ c:irua:191432 | Serial | 7186 | ||
Permanent link to this record | |||||
Author | Ghidelli, M.; Orekhov, A.; Bassi, A.L.; Terraneo, G.; Djemia, P.; Abadias, G.; Nord, M.; Béché, A.; Gauquelin, N.; Verbeeck, J.; Raskin, J.-p.; Schryvers, D.; Pardoen, T.; Idrissi, H. | ||||
Title | Novel class of nanostructured metallic glass films with superior and tunable mechanical properties | Type | A1 Journal article | ||
Year | 2021 | Publication | Acta Materialia | Abbreviated Journal | Acta Mater |
Volume | Issue | Pages | 116955 | ||
Keywords | A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT) | ||||
Abstract | A novel class of nanostructured Zr50Cu50 (%at.) metallic glass films with superior and tunable mechanical properties is produced by pulsed laser deposition. The process can be controlled to synthetize a wide range of film microstructures including dense fully amorphous, amorphous embedded with nanocrystals and amorphous nano-granular. A unique dense self-assembled nano-laminated atomic arrangement characterized by alternating Cu-rich and Zr/O-rich nanolayers with different local chemical enrichment and amorphous or amorphous-crystalline composite nanostructure has been discovered, while significant in-plane clustering is reported for films synthetized at high deposition pressures. This unique nanoarchitecture is at the basis of superior mechanical properties including large hardness and elastic modulus up to 10 and 140 GPa, respectively and outstanding total elongation to failure (>9%), leading to excellent strength/ductility balance, which can be tuned by playing with the film architecture. These results pave the way to the synthesis of novel class of engineered nanostructured metallic glass films with high structural performances attractive for a number of applications in microelectronics and coating industry. |
||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000670077800004 | Publication Date | 2021-05-12 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 1359-6454 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 5.301 | Times cited | 27 | Open Access | OpenAccess |
Notes | H.I. is mandated by the Belgian National Fund for Scientific Research (FSR-FNRS). This work was supported by the Fonds de la Recherche Scientifique – FNRS under Grant T.0178.19 and Grant CDR– J011320F. We acknowledge funding for the direct electron detector used in the 4D stem studies from the Hercules fund 'Direct electron detector for soft matter TEM' from the Flemish Government J.V acknowledges funding from the European Union's Horizon 2020 research and innovation program under grant agreement No 823717 – ESTEEM3. A.O. has received partial funding from the GOA project “Solarpaint” of the University of Antwerp. A.B. and J.V. acknowledge funding through FWO project G093417N ('Compressed sensing enabling low dose imaging in transmission electron microscopy') from the Flanders Research Fund. M.G. and A.L.B acknowledge Chantelle Ekanem for support in PLD depositions. | Approved | Most recent IF: 5.301 | ||
Call Number | EMAT @ emat @c:irua:178142 | Serial | 6761 | ||
Permanent link to this record | |||||
Author | Van den Broek, W.; Reed, B.W.; Béché, A.; Velazco, A.; Verbeeck, J.; Koch, C.T. | ||||
Title | Various compressed sensing setups evaluated against Shannon sampling under constraint of constant illumination | Type | A1 Journal article | ||
Year | 2019 | Publication | IEEE transactions on computational imaging | Abbreviated Journal | |
Volume | 5 | Issue | 3 | Pages | 502-514 |
Keywords | A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT) | ||||
Abstract | Under the constraint of constant illumination, an information criterion is formulated for the Fisher information that compressed sensing measurements in optical and transmission electron microscopy contain about the underlying parameters. Since this approach requires prior knowledge of the signal's support in the sparse basis, we develop a heuristic quantity, the detective quantum efficiency (DQE), that tracks this information criterion well without this knowledge. In this paper, it is shown that for the investigated choice of sensing matrices, and in the absence of read-out noise, i.e., with only Poisson noise present, compressed sensing does not raise the amount of Fisher information in the recordings above that of Shannon sampling. Furthermore, enabled by the DQE's analytical tractability, the experimental designs are optimized by finding out the optimal fraction of on pixels as a function of dose and read-out noise. Finally, we introduce a regularization and demonstrate, through simulations and experiment, that it yields reconstructions attaining minimum mean squared error at experimental settings predicted by the DQE as optimal. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000480352600013 | Publication Date | 2019-01-24 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 2333-9403 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 4.546 | Times cited | 7 | Open Access | |
Notes | ; This work was supported by the Hercules fund from the Flemish Government (Qu-Ant-EM microscope used for the experimental data). The work of W. Van den Broek was supported by the DFG under Grant BR 5095/2-1 (Compressed sensing in ptychography and transmission electron microscopy). The work of A. Beche, A. Velazco, and J. Verbeeck was supported by the FWO under Grant G093417N (Compressed sensing enabling low dose imaging in transmission electron microscopy). The work of Christoph T. Koch was supported by the DFG under Grant CRC 951. The associate editor coordinating the review of this manuscript and approving it for publication was Dr. Chrysanthe Preza. ; | Approved | Most recent IF: NA | ||
Call Number | UA @ admin @ c:irua:161792 | Serial | 5368 | ||
Permanent link to this record | |||||
Author | Verbeeck, J.; Béché, A.; van den Broek, W. | ||||
Title | A holographic method to measure the source size broadening in STEM | Type | A1 Journal article | ||
Year | 2012 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 120 | Issue | Pages | 35-40 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Source size broadening is an important resolution limiting effect in modern STEM experiments. Here, we propose an alternative method to measure the source size broadening making use of a holographic biprism to create interference patterns in an empty Ronchigram. This allows us to measure the exact shape of the source size broadening with a much better sampling than previously possible. We find that the shape of the demagnified source deviates considerably from a Gaussian profile that is often assumed. We fit the profile with a linear combination of a Gaussian and a bivariate Cauchy distribution showing that even though the full width at half maximum is similar to previously reported measurements, the tails of the profile are considerable wider. This is of fundamental importance for quantitative comparison of STEM simulations with experiments as these tails make the image contrast dependent on the interatomic distance, an effect that cannot be reproduced by a single Gaussian profile of fixed width alone. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000308082600005 | Publication Date | 2012-06-01 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 29 | Open Access | |
Notes | This work was supported by funding from the European Research Council under the 7th Framework Program (FP7), ERC Grant no. 246791 COUNTATOMS and ERC Starting Grant 278510 VORTEX. The Qu-Ant-EM microscope was partly funded by the Hercules fund from the Flemish Government. W. Van den Broek acknowledges funding from the Condor project, a project under the supervision of the Embedded Systems Institute (ESI) and FEI. This project is partially supported by the Dutch Ministry of Economic Affairs under the BSIK program. ECASJO_; | Approved | Most recent IF: 2.843; 2012 IF: 2.470 | ||
Call Number | UA @ lucian @ c:irua:100466UA @ admin @ c:irua:100466 | Serial | 1483 | ||
Permanent link to this record |