Records |
Links |
|
Author |
Bach, D.; Störmer, H.; Schneider, R.; Gerthsen, D.; Verbeeck, J. |
|
|
Title |
EELS investigations of different niobium oxide phases |
Type |
A1 Journal article |
|
Year |
2006 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
|
|
Volume |
12 |
Issue |
5 |
Pages |
416-423 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
Electron energy loss spectra in conjunction with near-edge fine structures of purely stoichiometric niobium monoxide (NbO) and niobium pentoxide (Nb2O5) reference materials were recorded. The structures of the niobium oxide reference materials were checked by selected area electron diffraction to ensure a proper assignment of the fine structures. NbO and Nb2O5 show clearly different energy loss near-edge fine structures of the Nb-M-4,M-5 and -M-2,M-3 edges and of the O-K edge, reflecting the specific local environments of the ionized atoms. To distinguish the two oxides in a quantitative manner, the intensities under the Nb-M-4,M-5 as well as Nb-M-2,M-3 edges and the O-K edge were measured and their ratios calculated. k-factors were also derived from these measurements. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Cambridge, Mass. |
Editor |
|
|
|
Language |
|
Wos |
000241181400007 |
Publication Date |
2006-09-19 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1431-9276;1435-8115; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.891 |
Times cited |
50 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 1.891; 2006 IF: 2.108 |
|
|
Call Number |
UA @ lucian @ c:irua:60979UA @ admin @ c:irua:60979 |
Serial |
789 |
|
Permanent link to this record |
|
|
|
|
Author |
Verbeeck, J.; Van Aert, S.; Zhang, L.; Haiyan, T.; Schattschneider, P.; Rosenauer, A. |
|
|
Title |
Computational aspects in quantitative EELS |
Type |
A1 Journal article |
|
Year |
2010 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
|
|
Volume |
16 |
Issue |
S:2 |
Pages |
240-241 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Cambridge, Mass. |
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2010-08-26 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1431-9276;1435-8115; |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
1.891 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 1.891; 2010 IF: 3.259 |
|
|
Call Number |
UA @ lucian @ c:irua:96556UA @ admin @ c:irua:96556 |
Serial |
454 |
|
Permanent link to this record |
|
|
|
|
Author |
Verlinden, G.; Gijbels, R.; Geuens, I. |
|
|
Title |
Chemical microcharacterization of ultrathin iodide conversion layers and adsorbed thiocyanate surface layers on silver halide microcrystals with time-of-flight SIMS |
Type |
A1 Journal article |
|
Year |
2002 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
|
|
Volume |
8 |
Issue |
3 |
Pages |
216-226 |
|
|
Keywords |
A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT) |
|
|
Abstract |
The technique of imaging time-of-flight secondary ion mass spectrometry (TOF-SIMS) and dual beam depth,profiling has been used to study the composition of the surface of tabular silver halide microcrystals. Analysis of individual microcrystals with a size well below 1 mum from a given emulsion is possible. The method is successfully applied for the characterization of silver halide microcrystals with subpercent global iodide concentrations confined in surface layers with a thickness below 5 nm. The developed TOF-SIMS analytical procedure is explicitly demonstrated for the molecular imaging of adsorbed thiocyanate layers (SCN) at crystal surfaces of individual crystals and for the differentiation of iodide conversion layers synthesized with KI and with AgI micrates (nanocrystals with a size between 10 and 50 nm). It can be concluded that TOF-SIMS as a microanalytical, surface-sensitive technique has some unique properties over other analytical techniques for the study of complex structured surface layers of silver halide microcrystals. This offers valuable information to support the synthesis of future photographic emulsions. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Cambridge, Mass. |
Editor |
|
|
|
Language |
|
Wos |
000179055900007 |
Publication Date |
2002-11-13 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1431-9276; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.891 |
Times cited |
1 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 1.891; 2002 IF: 1.733 |
|
|
Call Number |
UA @ lucian @ c:irua:103876 |
Serial |
349 |
|
Permanent link to this record |
|
|
|
|
Author |
Vega Ibañez, F.; Béché, A.; Verbeeck, J. |
|
|
Title |
Can a programmable phase plate serve as an aberration corrector in the transmission electron microscope (TEM)? |
Type |
A1 Journal article |
|
Year |
2022 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
|
|
Volume |
|
Issue |
|
Pages |
Pii S1431927622012260-10 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
Current progress in programmable electrostatic phase plates raises questions about their usefulness for specific applications. Here, we explore different designs for such phase plates with the specific goal of correcting spherical aberration in the transmission electron microscope (TEM). We numerically investigate whether a phase plate could provide down to 1 angstrom ngstrom spatial resolution on a conventional uncorrected TEM. Different design aspects (fill factor, pixel pattern, symmetry) were evaluated to understand their effect on the electron probe size and current density. Some proposed designs show a probe size () down to 0.66 angstrom, proving that it should be possible to correct spherical aberration well past the 1 angstrom limit using a programmable phase plate consisting of an array of electrostatic phase-shifting elements. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000849975400001 |
Publication Date |
2022-09-21 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.8 |
Times cited |
3 |
Open Access |
OpenAccess |
|
|
Notes |
All authors acknowledge funding from the Flemish Research Fund under contract G042820N “Exploring adaptive optics in transmission electron microscopy”. J.V. acknowledges funding from the European Union’s Horizon 2020 Research Infrastructure – Integrating Activities for Advanced Communities under grant agreement No 823717 – ESTEEM3 and from the University of Antwerp through a TOP BOF project.; esteem3reported; esteem3jra |
Approved |
Most recent IF: 2.8 |
|
|
Call Number |
UA @ admin @ c:irua:190627 |
Serial |
7134 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Aert, S.; Verbeeck, J.; Bals, S.; Erni, R.; van Dyck, D.; Van Tendeloo, G. |
|
|
Title |
Atomic resolution mapping using quantitative high-angle annular dark field scanning transmission electron microscopy |
Type |
A1 Journal article |
|
Year |
2009 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
|
|
Volume |
15 |
Issue |
S:2 |
Pages |
464-465 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Cambridge, Mass. |
Editor |
|
|
|
Language |
|
Wos |
000208119100230 |
Publication Date |
2009-07-27 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1431-9276;1435-8115; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.891 |
Times cited |
1 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 1.891; 2009 IF: 3.035 |
|
|
Call Number |
UA @ lucian @ c:irua:96555UA @ admin @ c:irua:96555 |
Serial |
178 |
|
Permanent link to this record |
|
|
|
|
Author |
Leroux, F.; Bladt, E.; Timmermans, J.-P.; Van Tendeloo, G.; Bals, S. |
|
|
Title |
Annular dark-field transmission electron microscopy for low contrast materials |
Type |
A1 Journal article |
|
Year |
2013 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
|
|
Volume |
19 |
Issue |
3 |
Pages |
629-634 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
Imaging soft matter by transmission electron microscopy (TEM) is anything but straightforward. Recently, interest has grown in developing alternative imaging modes that generate contrast without additional staining. Here, we present a dark-field TEM technique based on the use of an annular objective aperture. Our experiments demonstrate an increase in both contrast and signal-to-noise ratio in comparison to conventional bright-field TEM. The proposed technique is easy to implement and offers an alternative imaging mode to investigate soft matter. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Cambridge, Mass. |
Editor |
|
|
|
Language |
|
Wos |
000319126300014 |
Publication Date |
2013-04-04 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1431-9276;1435-8115; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.891 |
Times cited |
5 |
Open Access |
|
|
|
Notes |
262348 Esmi; Fwo G002410n G018008 |
Approved |
Most recent IF: 1.891; 2013 IF: 2.161 |
|
|
Call Number |
UA @ lucian @ c:irua:108712 |
Serial |
133 |
|
Permanent link to this record |
|
|
|
|
Author |
Ning, S.; Xu, W.; Ma, Y.; Loh, L.; Pennycook, T.J.; Zhou, W.; Zhang, F.; Bosman, M.; Pennycook, S.J.; He, Q.; Loh, N.D. |
|
|
Title |
Accurate and Robust Calibration of the Uniform Affine Transformation Between Scan-Camera Coordinates for Atom-Resolved In-Focus 4D-STEM Datasets |
Type |
A1 Journal article |
|
Year |
2022 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
|
|
Volume |
|
Issue |
|
Pages |
1-11 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
Accurate geometrical calibration between the scan coordinates and the camera coordinates is critical in four-dimensional scanning transmission electron microscopy (4D-STEM) for both quantitative imaging and ptychographic reconstructions. For atomic-resolved, in-focus 4D-STEM datasets, we propose a hybrid method incorporating two sub-routines, namely a J-matrix method and a Fourier method, which can calibrate the uniform affine transformation between the scan-camera coordinates using raw data, without a priori knowledge about the crystal structure of the specimen. The hybrid method is found robust against scan distortions and residual probe aberrations. It is also effective even when defects are present in the specimen, or the specimen becomes relatively thick. We will demonstrate that a successful geometrical calibration with the hybrid method will lead to a more reliable recovery of both the specimen and the electron probe in a ptychographic reconstruction. We will also show that, although the elimination of local scan position errors still requires an iterative approach, the rate of convergence can be improved, and the residual errors can be further reduced if the hybrid method can be firstly applied for initial calibration. The code is made available as a simple-to-use tool to correct affine transformations of the scan-camera coordinates in 4D-STEM experiments. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000767045700001 |
Publication Date |
2022-03-09 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.8 |
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
N. D. Loh kindly acknowledges support from NUS Early Career Research Award (R-154-000-B35-133), MOE’s AcRF Tier 1 grant nr. R-284-000-172-114 and NRF CRP grant number NRF-CRP16-2015-05. Q. He would also like to acknowledge the support of the National Research Foundation (NRF) Singapore, under its NRF Fellowship (NRF-NRFF11-2019-0002). W. Zhou acknowledges the support from Beijing Outstanding Young Scientist Program (BJJWZYJH01201914430039). F. Zhang acknowledges the support of the National Natural Science Foundation of China (11775105, 12074167). T. J. Pennycook acknowledges funding under the European Union’s Horizon 2020 research and innovation programme from the European Research Council (ERC) Grant agreement No. 802123-HDEM. |
Approved |
Most recent IF: 2.8 |
|
|
Call Number |
EMAT @ emat @c:irua:186958 |
Serial |
6957 |
|