|
Records |
Links |
|
Author |
Baez, J.F.; Compton, M.; Chahrati, S.; Cánovas, R.; Blondeau, P.; Andrade, F.J. |
|
|
Title |
Controlling the mixed potential of polyelectrolyte-coated platinum electrodes for the potentiometric detection of hydrogen peroxide |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Analytica Chimica Acta |
Abbreviated Journal |
Anal Chim Acta |
|
|
Volume |
1097 |
Issue |
|
Pages |
204-213 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The use of a Pt electrode coated with a layer of Nafion has been described in previous works as an attractive way to perform the potentiometric detection of hydrogen peroxide. Despite of the attractive features of this approach, the nature of the non-Nernstian response of this system was not properly addressed. In this work, using a mixed potential model, the open circuit potential of the Pt electrode is shown to be under kinetic control of the oxygen reduction reaction (ORR). It is proposed that hydrogen peroxide acts as an oxygenated species that blocks free sites on the Pt surface, interfering with the ORR. Therefore, the effect of the polyelectrolyte coating can be understood in terms of the modulation of the factors that affects the kinetics of the ORR, such as an increase of the H+ concentration, minimization of the effect of the spectator species, etc. Because of the complexity and the lack of models that accurately describe systems with practical applications, this work is not intended to provide a mechanistic but rather a phenomenological view on problem. A general framework to understand the factors that affect the potentiometric response is provided. Experimental evidence showing that the use of polyelectrolyte coatings are a powerful way to control the mixed potential open new ways for the development of robust and simple potentiometric sensors. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2019-11-13 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670; 1873-4324 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
6.2 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 6.2; 2020 IF: 4.95 |
|
|
Call Number |
UA @ admin @ c:irua:184381 |
Serial |
7731 |
|
Permanent link to this record |
|
|
|
|
Author |
Parrilla, M.; Montiel, F.N.; Van Durme, F.; De Wael, K. |
|
|
Title |
Derivatization of amphetamine to allow its electrochemical detection in illicit drug seizures |
Type |
A1 Journal article |
|
Year |
2021 |
Publication |
Sensors And Actuators B-Chemical |
Abbreviated Journal |
Sensor Actuat B-Chem |
|
|
Volume |
337 |
Issue |
|
Pages |
129819 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Amphetamine (AMP) is posing critical issues in our society being one of the most encountered drugs-of-abuse in the current illicit market. The continuous drug production in Europe urges the development of new tools for the rapid on-site determination of illicit drugs such as AMP. However, the direct electrochemical detection of AMP is a challenge because the molecule is non-electroactive at the potential window of conventional graphite SPEs. For this reason, a derivatization step is needed to convert the primary amine into an electroactive oxidizable group. Herein, the rapid electrochemical detection of AMP in seized samples based on the derivatization by 1,2-naphthoquinone-4-sulfonate (NQS) is presented by using square wave voltammetry (SWV) at graphite screen-printed electrodes (SPEs). First, a detailed optimization of the key parameters and the analytical performance is provided. The method showed a sensitivity of 7.9 µA mM-1 within a linear range from 50 to 500 µM, a limit of detection of 22.2 µM, and excellent reproducibility (RSD = 4.3%, n = 5 at 500 µM). Subsequently, the effect of NQS on common cutting agents for the selective detection of AMP is addressed. The comparison of the method with drugs-of-abuse containing secondary and tertiary amines confirms the selectivity of the method. Finally, the concept is applied to quantify AMP in 20 seized samples provided by forensic laboratories, exhibiting an accuracy of 97.3 ± 10.5%. Overall, the fast analysis of samples with the electrochemical profiling of derivatized AMP exhibits a straightforward on-site screening aiming to facilitate the tasks of law enforcement agents in the field. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000640386500001 |
Publication Date |
2021-03-19 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0925-4005 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
5.401 |
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
|
Approved |
Most recent IF: 5.401 |
|
|
Call Number |
UA @ admin @ c:irua:176353 |
Serial |
7762 |
|
Permanent link to this record |
|
|
|
|
Author |
Blidar, A.; Trashin, S.; Carrion, E.N.; Gorun, S.M.; Cristea, C.; De Wael, K. |
|
|
Title |
Enhanced photoelectrochemical detection of an analyte triggered by its concentration by a singlet oxygen-generating fluoro photosensitizer |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Acs Sensors |
Abbreviated Journal |
Acs Sensors |
|
|
Volume |
5 |
Issue |
11 |
Pages |
3501-3509 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The use of a photocatalyst (photosensitizer) which produces singlet oxygen instead of enzymes for oxidizing analytes creates opportunities for designing cost-efficient and sensitive photoelectrochemical sensors. We report that perfluoroisopropyl-substituted zinc phthalocyanine (F64PcZn) interacts specifically with a complex phenolic compound, the antibiotic rifampicin (RIF), but not with hydroquinone or another complex phenolic compound, the antibiotic doxycycline. The specificity is imparted by the selective preconcentration of RIF in the photocatalytic layer, as revealed by electrochemical and optical measurements, complemented by molecular modeling that confirms the important role of a hydrophobic cavity formed by the iso-perfluoropropyl groups of the photocatalyst. The preconcentration effect favorably enhances the RIF photoelectrochemical detection limit as well as sensitivity to nanomolar (ppb) concentrations, LOD = 7 nM (6 ppb) and 2.8 A.M-1.cm(-2), respectively. The selectivity to RIF, retained in the photosensitizer layer, is further enhanced by the selective removal of all unretained phenols via simple washing of the electrodes with pure buffer. The utility of the sensor for analyzing municipal wastewater was demonstrated. This first demonstration of enhanced selectivity and sensitivity due to intrinsic interactions of a molecular photocatalyst (photosensitizer) with an analyte, without use of a biorecognition element, may allow the design of related, robust, simple, and viable sensors. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000595550100021 |
Publication Date |
2020-10-29 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2379-3694 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
8.9 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 8.9; 2020 IF: NA |
|
|
Call Number |
UA @ admin @ c:irua:176057 |
Serial |
7913 |
|
Permanent link to this record |
|
|
|
|
Author |
Hoornaert, S.; van Malderen, H.; Van Grieken, R. |
|
|
Title |
Gypsum and other calcium-rich particles above the North Sea |
Type |
A1 Journal article |
|
Year |
1996 |
Publication |
Environmental science and technology |
Abbreviated Journal |
|
|
|
Volume |
30 |
Issue |
|
Pages |
1515-1520 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Ca-containing particles, especially CaSO4 particles, have been encountered in several atmospheric aerosol studies. An overview is given of the different sources of airborne Ca-containing particles, The North Sea atmosphere is studied to identify the different Ca-containing particle types and to find the correlation between their occurrence and the source regions of the corresponding air masses. About 50000 individual aerosol samples were collected above the Southern Eight of the North Sea for several wind directions and analyzed for their composition using electron probe X-ray microanalysis. Nonhierarchical cluster analysis is performed on the data to reveal the different particle types, their relative abundances and their sources. CaSO4 in most cases constitutes the largest fraction of the Ca-containing particles. Extremely high numbers of CaSO4 particles are found for northeastern winds, coming from the central part of Germany, suggesting that a great fraction is derived from anthropogenic sources located in this region. Among the other Ca-containing particle types are the aluminosilicates, CaCO3, Fe-Ca-rich particles, and CaSO4 or CaCO3 in combination with NaCl. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1996UG95400042 |
Publication Date |
2002-07-26 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0013-936x; 1520-5851 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:14647 |
Serial |
8015 |
|
Permanent link to this record |
|
|
|
|
Author |
van Malderen, H.; Hoornaert, S.; Van Grieken, R. |
|
|
Title |
Identification of individual aerosol particles containing Cr, Pb, and Zn above the North Sea |
Type |
A1 Journal article |
|
Year |
1996 |
Publication |
Environmental science and technology |
Abbreviated Journal |
|
|
|
Volume |
30 |
Issue |
|
Pages |
489-498 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Aerosol samples have been collected over the southern bight of the North Sea from an aircraft. In this way, 96 samples were taken for single-particle analysis during 16 flights. Almost 45 000 individual particles were analyzed with electron probe X-ray microanalysis. More than 5000 of these were found to contain significant concentrations of one or more of the heavy metals Cr, Pb, and Zn. With the help of hierarchical, nonhierarchical, and fuzzy clustering techniques, various heavy metal-containing particle types could be identified. Significant differences in abundances were detected in the North Sea heavy metal aerosol, depending on the origin of the air masses. In samples with continental influence 50 times more Zn- and Pb-containing particles were found than in samples with a marine history. For Cr, on the other hand, we found abundances in the marine sector that were one-third of the values for continental sectors. This might point to a rather undefined marine source, which could be the recycling of previously deposited material by reinjection into the atmosphere by sea spray. The highest values for Cr-, Pb-, and Zn-containing particles were always detected under southeastern wind directions. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1996TT49600036 |
Publication Date |
2002-07-26 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0013-936x; 1520-5851 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:14639 |
Serial |
8053 |
|
Permanent link to this record |
|
|
|
|
Author |
Zwozdziak, A.; Sowka, I.; Krupińska, B.; Zwozdziak, J.; Nych, A. |
|
|
Title |
Infiltration or indoor sources as determinants of the elemental composition of particulate matter inside a school in Wroclaw, Poland? |
Type |
A1 Journal article |
|
Year |
2013 |
Publication |
Building and environment |
Abbreviated Journal |
|
|
|
Volume |
66 |
Issue |
|
Pages |
173-180 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Children's exposure to air pollution requires a focus on air quality in places where they spend most time, e.g. in schools. Therefore, understanding how indoor elemental concentrations relate the outdoor ones is necessary to create healthy indoor school environment. The aims of this study were to examine the elemental composition of particulate matter (PM1, PM2.5, PM10) in the school and also to investigate to what degree indoor elemental concentrations are affected by outdoor air or generated inside the school. The measurements were performed inside and outside the public school building in the centre of the city. It was observed that concentrations of most elements were higher at school than outside. The dominant elements in PM1 both indoors and outdoors were S, Cl, K, and Zn. PM2.5 and PM10 fractions inside the school were clearly enriched in elements of mineral origin, additionally S, Zn, K and Cl were also present in high concentrations both indoors and outdoors. Results suggested that a significant contribution to indoor Zn, Pb and S concentrations in the PM2.5 fraction was from penetration of outdoor air. 88%, 80% and 90% of the observed total variations in indoor concentrations of Zn, Pb, and S were explained by the linear relationship between indoor and outdoor concentrations. The lack of correlation between indoor and outdoor concentrations obtained for Si, Ca, Ti, Sr indicated that these metals were more likely to originate from indoor sources. (C) 2013 Elsevier Ltd. All rights reserved. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000321423500017 |
Publication Date |
2013-05-09 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0360-1323 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:109788 |
Serial |
8087 |
|
Permanent link to this record |
|
|
|
|
Author |
Matuszewski, K.; Matysiak, H.; Jaroszewicz, J.; de Nolf, W.; Kubiak, K.; Kurzydlowski, K.J. |
|
|
Title |
Influence of Bridgman process conditions on microstructure and porosity of single crystal Ni-base superalloy CMSX-4 |
Type |
A1 Journal article |
|
Year |
2014 |
Publication |
International journal of cast metals research |
Abbreviated Journal |
|
|
|
Volume |
27 |
Issue |
6 |
Pages |
329-335 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Synchrotron radiation micro-X-ray fluorescence and micro-X-ray diffraction analysis, micro-computed tomography and transmission electron microscopy were used to investigate the microstructure of turbine blades made of a second generation nickel based superalloy CMSX-4 manufactured by investment casting process via Bridgman technique. The dependence of microstructure on process parameters, among others, on the withdrawal rate was analysed. The results set the stage for optimising the microstructure of the blades in terms of their mechanical properties. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000346143500002 |
Publication Date |
2014-04-14 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1364-0461 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:122745 |
Serial |
8089 |
|
Permanent link to this record |
|
|
|
|
Author |
Christiansen, T.; Cotte, M.; de Nolf, W.; Mouro, E.; Reyes-Herrera, J.; De Meyer, S.; Vanmeert, F.; Salvado, N.; Gonzalez, V.; Lindelof, P.E.; Mortensen, K.; Ryholt, K.; Janssens, K.; Larsen, S. |
|
|
Title |
Insights into the composition of ancient Egyptian red and black inks on papyri achieved by synchrotron-based microanalyses |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Proceedings Of The National Academy Of Sciences Of The United States Of America |
Abbreviated Journal |
P Natl Acad Sci Usa |
|
|
Volume |
117 |
Issue |
45 |
Pages |
27825-27835 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
A hitherto unknown composition is highlighted in the red and black inks preserved on ancient Egyptian papyri from the Roman period (circa 100 to 200 CE). Synchrotron-based macro-X-ray fluo-rescence (XRF) mapping brings to light the presence of iron (Fe) and lead (Pb) compounds in the majority of the red inks inscribed on 12 papyrus fragments from the Tebtunis temple library. The iron-based compounds in the inks can be assigned to ocher, notably due to the colocalization of Fe with aluminum, and the detection of hematite (Fe2O3) by micro-X-ray diffraction. Using the same techniques together with micro-Fourier transform infrared spectroscopy, Pb is shown to be associated with fatty acid phosphate, sulfate, chloride, and carboxylate ions. Moreover, microXRF maps reveal a peculiar distribution and colocalization of Pb, phosphorus (P), and sulfur (S), which are present at the micrometric scale resembling diffused “coffee rings” surrounding the ocher particles imbedded in the red letters, and at the submicrometric scale concentrated in the papyrus cell walls. A similar Pb, P, and S composition was found in three black inks, suggesting that the same lead components were employed in the manufacture of carbon-based inks. Bearing in mind that pigments such as red lead (Pb3O4) and lead white (hydrocerussite [Pb-3(CO3)(2)(OH)(2)] and/or cerussite [PbCO3]) were not detected, the results presented here suggest that the lead compound in the ink was used as a drier rather than as a pigment. Accordingly, the study calls for a reassessment of the composition of lead-based components in ancient Mediterranean pigments. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000590753400016 |
Publication Date |
2020-10-27 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0027-8424; 1091-6490 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
11.1 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 11.1; 2020 IF: 9.661 |
|
|
Call Number |
UA @ admin @ c:irua:174323 |
Serial |
8107 |
|
Permanent link to this record |
|
|
|
|
Author |
Kabsch-Korbutowicz, M.; Kozak, A.; Krupińska, B. |
|
|
Title |
Ion exchange-ultrafiltration integrated process as a useful method in removing natural organic matter from water |
Type |
A1 Journal article |
|
Year |
2008 |
Publication |
Environment protection engineering |
Abbreviated Journal |
|
|
|
Volume |
34 |
Issue |
2 |
Pages |
79-93 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The experiments conducted are focused on natural organic substances, removal from water in ion-exchange process, ultrafiltration process and ion exchange-ultrafiltration integrated process. The water from the Odra River and model solution were investigated. In treatment processes, various doses of 5 anion-exchange resins as well as polyethersulphone membranes with different cut-offs were used. The efficiency of process was determined by measuring a decrease both in the colour intensity and the UV 254 nm absorbance. The results show that separation efficiency in integrated process depends on resin dose added to water before ultrafiltration and on the membrane cut-off as well. Among the resins tested the most efficient was MIEX (R) resin. The ion-exchange process carried out prior to the ultrafiltration increased, especially for high cut-off membranes, NOM retention and resulted in the decrease of membrane fouling intensity. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000257186600008 |
Publication Date |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0324-8828 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:94633 |
Serial |
8131 |
|
Permanent link to this record |
|
|
|
|
Author |
Baly, L.; Quesada, I.; Murray, A.S.; Martin, G.; van Espen, P.; Arteche, R.; Jain, M. |
|
|
Title |
Modeling the charge deposition in quartz grains during natural irradiation and its influence on the optically stimulated luminescence signal |
Type |
A1 Journal article |
|
Year |
2021 |
Publication |
Radiation Measurements |
Abbreviated Journal |
Radiat Meas |
|
|
Volume |
142 |
Issue |
|
Pages |
106564 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The rate of charge deposition in quartz grains irradiated in natural conditions is computed by radiation transport modeling. Quartz luminescence models are modified with the addition of the resulting charge deposition term, and the influence of this process on the optically stimulated luminescence (OSL) signal is analyzed. The results indicate that the charge deposition occurring in the quartz grain during the time of residence within rock could lead to the depletion of trapped holes in the recombination centres. For the two different quartz models investigated here, complete depletion is expected to occur for rock ages between 500 Ma and 1100 Ma. It is predicted that for sedimentary quartz derived from such rocks, the OSL signal is dominated by the slow component. It was also found that the shape and saturation level of the natural sensitivity-corrected dose response curve (DRC) of quartz is affected by the charge deposition; specifically, a linear reduction of the saturation level with the age of the rock is observed. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000639160300003 |
Publication Date |
2021-03-18 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1350-4487 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.442 |
Times cited |
|
Open Access |
Not_Open_Access |
|
|
Notes |
|
Approved |
Most recent IF: 1.442 |
|
|
Call Number |
UA @ admin @ c:irua:178307 |
Serial |
8265 |
|
Permanent link to this record |
|
|
|
|
Author |
Cánovas, R.; Blondeau, P.; Andrade, F.J. |
|
|
Title |
Modulating the mixed potential for developing biosensors: Direct potentiometric determination of glucose in whole, undiluted blood |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Biosensors & Bioelectronics |
Abbreviated Journal |
Biosens Bioelectron |
|
|
Volume |
163 |
Issue |
|
Pages |
112302-112306 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The growing demand for tools to generate chemical information in decentralized settings is creating a vast range of opportunities for potentiometric sensors, since their combination of robustness, simplicity of operation and cost can hardly be rivalled by any other technique. In previous works, we have shown that the mixed potential of a Pt electrode can be controlled with analytical purposes using a coating of Nafion, thus providing a way to develop a potentiometric biosensor for glucose. Unfortunately, the linear range of this device did not match the relevant clinical range for glucose in blood. This work presents a novel strategy to control the mixed potential that allows the development of a potentiometric biosensor for the direct detection of glucose in whole, undiluted blood without any sample pretreatment. By changing the ionomer, the analytical response can be tuned, shifting the linear range while keeping the sensitivity. Aquivion, a polyelectrolyte from the same family as Nafion, is used to stabilize the mixed potential of a platinized paper-based electrode, to entrap the enzyme and to reduce the interference from negatively charged species. Factors affecting the generation of the signal and the principle of detection are discussed. Optimization of the biosensor composition was achieved with particular focus on the characterization of the linear range and sensitivity. The accurate measurement of blood sugar levels in a single drop of whole blood with excellent recovery is presented. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2020-05-18 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0956-5663 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
12.6 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 12.6; 2020 IF: 7.78 |
|
|
Call Number |
UA @ admin @ c:irua:184382 |
Serial |
8271 |
|
Permanent link to this record |
|
|
|
|
Author |
Celik, N.; Čevik, U.; Celik, A.; Koz, B. |
|
|
Title |
Natural and artificial radioactivity measurements in Eastern Black Sea region of Turkey |
Type |
A1 Journal article |
|
Year |
2009 |
Publication |
Journal of hazardous materials |
Abbreviated Journal |
|
|
|
Volume |
162 |
Issue |
1 |
Pages |
146-153 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
In the present work, naturally occurring radionuclides of (226)Ra, (232)Th and (40)K were measured in soil samples collected from the Eastern Black Sea region of Turkey. It was found that the activity concentrations ranged from 12 to 120 Bq kg(-1) for (226)Ra, from 13 to 121 Bq kg(-1) for (232)Th and from 204 to 1295 Bq kg(-1) for (40)K. Besides naturally occurring radionuclides, (137)Cs activity concentration was measured in soil, lichen and moss samples and it was found that (137)Cs activity concentration ranged from 27 to 775 Bq kg(-1) with for soil, from 29 to 879 Bq kg(-1) for lichen and from 67 to 1396 Bq kg(-1) for moss samples. Annual effective doses due to the naturally occurring radionuclides and (137)CS were estimated. Ecological half-lives of (137)CS in lichen and moss species were estimated. The decrease of the activity concentrations in the present measurements (2007) relative to those in 1993 indicated ecological half-lives between 1.36 and 2.96 years for lichen and between 1.35 and 2.85 years for moss species. (C) 2008 Elsevier B.V. All rights reserved. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000263149400019 |
Publication Date |
2008-05-10 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0304-3894 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:94562 |
Serial |
8296 |
|
Permanent link to this record |
|
|
|
|
Author |
Karabidak, S.M.; Čevik, U.; Kaya, S. |
|
|
Title |
A new method to compensate for counting losses due to system dead time |
Type |
A1 Journal article |
|
Year |
2009 |
Publication |
Nuclear instruments and methods in physics research : A: accelerators, spectrometers, detectors and associated equipment |
Abbreviated Journal |
|
|
|
Volume |
603 |
Issue |
3 |
Pages |
361-364 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Determination of count losses and pile-up pulse effects in quantitative and qualitative analysis became a vital step in various analyses. Therefore, compensating for counting losses is of importance. These counting losses are due to the pulse pile-up, paralyzable and non-paralyzable system dead time or a combination of these mechanisms. In this work, a new method is suggested for the correction of dead time losses resulting from the above mechanisms. For this purpose, a source code was developed. It was found that the peaking time was an important parameter over system dead time. The method suggested seems to be more effective even at high count rate. (C) 2009 Elsevier B.V. All rights reserved. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000266829400021 |
Publication Date |
2009-02-14 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0168-9002 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:94550 |
Serial |
8304 |
|
Permanent link to this record |
|
|
|
|
Author |
Safdar, M.; Khan, S.U.; Jänis, J. |
|
|
Title |
Progress toward catalytic micro- and nanomotors for biomedical and environmental applications |
Type |
A1 Journal article |
|
Year |
2018 |
Publication |
Advanced Materials |
Abbreviated Journal |
|
|
|
Volume |
30 |
Issue |
24 |
Pages |
1703660 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Synthetic micro‐ and nanomotors (MNMs) are tiny objects that can autonomously move under the influence of an appropriate source of energy, such as a chemical fuel, magnetic field, ultrasound, or light. Chemically driven MNMs are composed of or contain certain reactive material(s) that convert chemical energy of a fuel into kinetic energy (motion) of the particles. Several different materials have been explored over the last decade for the preparation of a wide variety of MNMs. Here, the discovery of materials and approaches to enhance the efficiency of chemically driven MNMs are reviewed. Several prominent applications of the MNMs, especially in the fields of biomedicine and environmental science, are also discussed, as well as the limitations of existing materials and future research directions. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000436455800006 |
Publication Date |
2018-02-07 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:175426 |
Serial |
8424 |
|
Permanent link to this record |
|
|
|
|
Author |
Piñera, I.; Cruz, C.M.; van Espen, P.; Abreu, Y.; Leyva, A. |
|
|
Title |
Study of dpa distributions in electron irradiated YBCO slabs through MCCM algorithm |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms |
Abbreviated Journal |
|
|
|
Volume |
274 |
Issue |
|
Pages |
191-194 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The Monte Carlo assisted Classical Method (MCCM) consists on a calculation procedure for determining the displacements per atom (dpa) distribution in solid materials. This algorithm allows studying the gamma and electron irradiation damage in different materials. It is based on the electrons elastic scattering classic theories and the use of Monte Carlo simulation for the physical processes involved. The present study deals with the Monte Carlo simulation of electron irradiation effects on YBa2Cu3O7-x (YBCO) slabs using the MCNPX code system. Displacements per atom distributions are obtained through the MCCM for electron irradiation up to 10 MeV. In-depth dpa profiles for electrons and positrons are obtained and analysed. Also, dpa contributions from each atomic specie in the material are calculated. It was found that the dpa distribution is more homogeneous in the material volume when increasing energy of incident electrons. Also, the dpa produced by positrons has no relevance when irradiating with electrons, in contrast with previous similar gamma irradiation studies. All the results are presented and discussed in this contribution. (C) 2011 Elsevier B.V. All rights reserved. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000301611900031 |
Publication Date |
2011-12-05 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0168-583x |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:97819 |
Serial |
8595 |
|
Permanent link to this record |
|
|
|
|
Author |
Ciftci, S.; Cánovas, R.; Neumann, F.; Paulraj, T.; Nilsson, M.; Crespo, G.A.; Madaboosi, N. |
|
|
Title |
The sweet detection of rolling circle amplification : glucose-based electrochemical genosensor for the detection of viral nucleic acid |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Biosensors & Bioelectronics |
Abbreviated Journal |
Biosens Bioelectron |
|
|
Volume |
151 |
Issue |
|
Pages |
112002-112008 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Herein, an isothermal padlock probe-based assay for the simple and portable detection of pathogens coupled with a glucose oxidase (GOx)-based electrochemical readout is reported. Infectious diseases remain a constant threat on a global scale, as in recurring pandemics. Rapid and portable diagnostics hold the promise to tackle the spreading of diseases and decentralising healthcare to point-of-care needs. Ebola, a hypervariable RNA virus causing fatalities of up to 90% for recent outbreaks in Africa, demands immediate attention for bedside diagnostics. The design of the demonstrated assay consists of a rolling circle amplification (RCA) technique, responsible for the generation of nucleic acid amplicons as RCA products (RCPs). The RCPs are generated on magnetic beads (MB) and subsequently, connected via streptavidin-biotin bonds to GOx. The enzymatic catalysis of glucose by the bound GOx allows for an indirect electrochemical measurement of the DNA target. The RCPs generated on the surface of the MB were confirmed by scanning electron microscopy, and among other experimental conditions such as the type of buffer, temperature, concentration of GOx, sampling and measurement time were evaluated for the optimum electrochemical detection. Accordingly, 125 μg mL−1 of GOx with 5 mM glucose using phosphate buffer saline (PBS), monitored for 1 min were selected as the ideal conditions. Finally, we assessed the analytical performance of the biosensing strategy by using clinical samples of Ebola virus from patients. Overall, this work provides a proof-of-concept bioassay for simple and portable molecular diagnostics of emerging pathogens using electrochemical detection, especially in resource-limited settings. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2019-12-30 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0956-5663 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
12.6 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 12.6; 2020 IF: 7.78 |
|
|
Call Number |
UA @ admin @ c:irua:184379 |
Serial |
8630 |
|
Permanent link to this record |
|
|
|
|
Author |
Liu, Y.; Cánovas, R.; Crespo, G.A.; Cuartero, M. |
|
|
Title |
Thin-layer potentiometry for creatinine detection in undiluted human urine using ion-exchange membranes as barriers for charged interferences |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Analytical Chemistry |
Abbreviated Journal |
Anal Chem |
|
|
Volume |
92 |
Issue |
4 |
Pages |
3315-3323 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Herein, thin-layer potentiometry combined with ion-exchange membranes as barriers for charged interferences is demonstrated for the analytical detection of creatinine (CRE) in undiluted human urine. Briefly, CRE diffuses through an anion-exchange membrane (AEM) from a sample contained in one fluidic compartment to a second reservoir, containing the enzyme CRE deiminase. There, CRE reacts with the enzyme, and the formation of ammonium is dynamically monitored by potentiometric ammonium-selective electrodes. This analytical concept is integrated into a lab-on-a-chip microfluidic cell that allows for a high sample throughput and the operation under stop-flow mode, which allows CRE to passively diffuse across the AEM. Conveniently, positively charged species (i.e., potassium, sodium, and ammonium, among others) are repelled by the AEM and never reach the ammonium-selective electrodes; thus, possible interference in the response can be avoided. As a result, the dynamic potential response of the electrodes is entirely ascribed to the stoichiometric formation of ammonium. The new CRE biosensor exhibits a Nernstian slope, within a linear range of response from 1 to 50 mM CRE concentration. As expected, the response time (15–60 min) primarily depends on the CRE diffusion across the AEM. CRE analysis in urine samples displayed excellent results, without requiring sample pretreatment (before the introduction of the sample in the microfluidic chip) and with high compatibility with development into a potential point-of-care clinical tool. In an attempt to decrease the analysis time, the presented analytical methodology for CRE detection is translated into an all-solid-state platform, in which the enzyme is immobilized on the surface of the ammonium-selective electrode and with the AEM on top. While more work is necessary in this direction, the CRE sensor appears to be promising for CRE analysis in both urine and blood. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2020-01-23 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2700; 5206-882x |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
7.4 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 7.4; 2020 IF: 6.32 |
|
|
Call Number |
UA @ admin @ c:irua:184380 |
Serial |
8667 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Echelpoel, R.; de Jong, M.; Daems, D.; van Espen, P.; De Wael, K. |
|
|
Title |
Unlocking the full potential of voltammetric data analysis : a novel peak recognition approach for (bio)analytical applications |
Type |
A1 Journal article |
|
Year |
2021 |
Publication |
Talanta |
Abbreviated Journal |
Talanta |
|
|
Volume |
233 |
Issue |
|
Pages |
122605 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Bridging the gap between complex signal data output and clear interpretation by non-expert end-users is a major challenge many scientists face when converting their scientific technology into a real-life application. Currently, pattern recognition algorithms are the most frequently encountered signal data interpretation algorithms to close this gap, not in the least because of their straight-forward implementation via convenient software packages. Paradoxically, just because their implementation is so straight-forward, it becomes cumbersome to integrate the expert's domain-specific knowledge. In this work, a novel signal data interpretation approach is presented that uses this domain-specific knowledge as its fundament, thereby fully exploiting the unique expertise of the scientist. The new approach applies data preprocessing in an innovative way that transcends its usual purpose and is easy to translate into a software application. Multiple case studies illustrate the straight-forward application of the novel approach. Ultimately, the approach is highly suited for integration in various (bio)analytical applications that require interpretation of signal data. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000668000500108 |
Publication Date |
2021-06-11 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0039-9140; 1873-3573 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
4.162 |
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
|
Approved |
Most recent IF: 4.162 |
|
|
Call Number |
UA @ admin @ c:irua:179417 |
Serial |
8712 |
|
Permanent link to this record |
|
|
|
|
Author |
Anaf, W.; Schalm, O. |
|
|
Title |
Climatic quality evaluation by peak analysis and segregation of low-, mid-, and high-frequency fluctuations, applied on a historic chapel |
Type |
A1 Journal article |
|
Year |
2019 |
Publication |
Building and environment |
Abbreviated Journal |
|
|
|
Volume |
148 |
Issue |
|
Pages |
286-293 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES) |
|
|
Abstract |
Heritage-related guidelines and standards recommend stable climatic conditions, since these contribute to the extension of heritage collections life. As a result, numerous museums and other heritage institutions implement (expensive) mitigation measures to achieve stable conditions. Nevertheless, temperature and relative humidity fluctuations are often still observed. This contribution demonstrates that the analysis of temperature and humidity peaks and drops helps to identify hazards which cause fluctuations in different frequency ranges. This hazard identification provides information on the type of mitigation actions that are required in the near future and in which order they need to be implemented. The approach is illustrated with a case study. A 22 month monitoring campaign was performed in a chapel in the center of Antwerp (Belgium) where the climatic conditions are controlled with a heating, ventilation and air conditioning (HVAC) system. Low-, mid- and high-frequency fluctuations were separated and discussed for their hazards. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000457116500024 |
Publication Date |
2018-11-15 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0360-1323 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:157569 |
Serial |
7672 |
|
Permanent link to this record |
|
|
|
|
Author |
Barich, H.; Cánovas, R.; De Wael, K. |
|
|
Title |
Electrochemical identification of hazardous phenols and their complex mixtures in real samples using unmodified screen-printed electrodes |
Type |
A1 Journal article |
|
Year |
2022 |
Publication |
Journal of electroanalytical chemistry : an international journal devoted to all aspects of electrode kynetics, interfacial structure, properties of electrolytes, colloid and biological electrochemistry. |
Abbreviated Journal |
J Electroanal Chem |
|
|
Volume |
904 |
Issue |
|
Pages |
115878 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab) |
|
|
Abstract |
The electrochemical behavior of some of the most relevant endocrine-disrupting phenols using unmodified carbon screen-printed electrodes (SPEs) is described for the first time. Experiments were made to assess the electrochemical behavior of phenol (PHOH), pentachlorophenol (PCP), 4-tert octylphenol (OP) and bisphenol A (BPA) and their determination in the most favorable conditions, using voltammetric methods such as cyclic voltammetry (CV), linear sweep voltammetry (LSV) and square wave voltammetry (SWV) in Britton Robinson (BR) buffer. Further, the usefulness of the electrochemical approach was validated with real samples from a local river and was compared to commercial phenols test kit, which is commonly used for on-site screening in industrial streams and wastewaters. Finally, the approach was compared with a lab-bench standard method using real samples, i.e., high-performance liquid chromatography with a photodiode array detector (HPLC-DAD). |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000741151200005 |
Publication Date |
2021-11-14 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1572-6657; 1873-2569 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
4.5 |
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
|
Approved |
Most recent IF: 4.5 |
|
|
Call Number |
UA @ admin @ c:irua:184384 |
Serial |
7150 |
|
Permanent link to this record |
|
|
|
|
Author |
Parrilla, M.; Joosten, F.; De Wael, K. |
|
|
Title |
Enhanced electrochemical detection of illicit drugs in oral fluid by the use of surfactant-mediated solution |
Type |
A1 Journal article |
|
Year |
2021 |
Publication |
Sensors And Actuators B-Chemical |
Abbreviated Journal |
Sensor Actuat B-Chem |
|
|
Volume |
348 |
Issue |
|
Pages |
130659 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab) |
|
|
Abstract |
Illicit drug consumption is a worldwide worrying phenomenon that troubles modern society. For this reason, law enforcement agencies (LEAs) are placing tremendous efforts into tackling the spreading of such substances among our community. New sensing technologies can facilitate the LEAs duties by providing portable and affordable analytical devices. Herein, we present for the first time a sensitive and low-cost electrochemical method, i.e. square-wave adsorptive stripping voltammetry on carbon screen-printed electrodes (SPE), for the detection of five illicit drugs (i.e. cocaine, heroin, 3,4-methylenedioxymethamphetamine, 4-chloro-alpha-pyrrolidinovalerophenone, and ketamine) in oral fluid by the aid of a surfactant. Particularly, the surfactant is adsorbed at the carbon electrode’s surface and yields the adsorption of illicit drug molecules, allowing for an enhanced electrochemical signal in comparison to surfactant-free media. First, the surfactant-mediated behavior is deeply explored at the SPE by cyclic voltammetry, electrochemical impedance spectroscopy, and Fourier-transform infrared spectroscopy. Subsequently, the electrochemical behavior of the five illicit drugs is studied and optimized to render optimal analytical performance. Accordingly, the analytical system exhibited a wide linear concentration range from 1 to 30 µM with sub-micromolar limits of detection and high sensitivity. This performance is similar to other reported electrochemical sensors, but with the advantage of using an unmodified SPE, thus avoiding costly and complex functionalization of the SPE. Finally, the methodology was evaluated in diluted oral fluid samples spiked with illicit drugs. Overall, this work describes a simple, rapid, portable, and sensitive method for the detection of illicit drugs aiming to provide oral fluid testing opportunities to LEAs. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000701915600005 |
Publication Date |
2021-08-27 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0925-4005 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
5.401 |
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
|
Approved |
Most recent IF: 5.401 |
|
|
Call Number |
UA @ admin @ c:irua:181307 |
Serial |
7912 |
|
Permanent link to this record |
|
|
|
|
Author |
Parrilla, M.; De Wael, K. |
|
|
Title |
Wearable self‐powered electrochemical devices for continuous health management |
Type |
A1 Journal article |
|
Year |
2021 |
Publication |
Advanced Functional Materials |
Abbreviated Journal |
Adv Funct Mater |
|
|
Volume |
31 |
Issue |
50 |
Pages |
2107042 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab) |
|
|
Abstract |
The wearable revolution is already present in society through numerous gadgets. However, the contest remains in fully deployable wearable (bio)chemical sensing. Its use is constrained by the energy consumption which is provided by miniaturized batteries, limiting the autonomy of the device. Hence, the combination of materials and engineering efforts to develop sustainable energy management is paramount in the next generation of wearable self-powered electrochemical devices (WeSPEDs). In this direction, this review highlights for the first time the incorporation of innovative energy harvesting technologies with top-notch wearable self-powered sensors and low-powered electrochemical sensors toward battery-free and self-sustainable devices for health and wellbeing management. First, current elements such as wearable designs, electrochemical sensors, energy harvesters and storage, and user interfaces that conform WeSPEDs are depicted. Importantly, the bottlenecks in the development of WeSPEDs from an analytical perspective, product side, and power needs are carefully addressed. Subsequently, energy harvesting opportunities to power wearable electrochemical sensors are discussed. Finally, key findings that will enable the next generation of wearable devices are proposed. Overall, this review aims to bring new strategies for an energy-balanced deployment of WeSPEDs for successful monitoring of (bio)chemical parameters of the body toward personalized, predictive, and importantly, preventive healthcare. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000694642500001 |
Publication Date |
2021-09-09 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1616-301x |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
12.124 |
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
|
Approved |
Most recent IF: 12.124 |
|
|
Call Number |
UA @ admin @ c:irua:181306 |
Serial |
8750 |
|
Permanent link to this record |
|
|
|
|
Author |
Alvarez-Martin, A.; Wilcop, M.; Anderson, R.; Wendt, D.; Barden, R.; Kavich, G.M. |
|
|
Title |
Investigation of volatile organic compounds in museum storage areas |
Type |
A1 Journal article |
|
Year |
2021 |
Publication |
Air Quality Atmosphere And Health |
Abbreviated Journal |
Air Qual Atmos Hlth |
|
|
Volume |
14 |
Issue |
11 |
Pages |
1797-1809 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp X-ray Imaging and Spectroscopy (AXIS) |
|
|
Abstract |
This study investigates the complex mixture of volatile organic compounds (VOCs) released by and accumulated within a collection of historic medicinal, pharmaceutical, and cosmetic artifacts housed at the National Museum of American History (Smithsonian Institution). In recent years, staff have become concerned, both for the safety of the objects and for personnel working in the collection, about strong unremediated odors accumulating within several storage cabinets. Museum staff also wondered if non-odorous off-gassing might need remediation. Solid-phase microextraction combined with gas chromatography–mass spectrometry analysis (SPME–GC–MS) was used to identify VOCs present in the storage room housing the collection. Over 160 compounds were detected and identified overall. Among these, 49 appeared to be directly related to ingredients used in the manufacture of many collection items. The results of the study suggest that SPME–GC–MS can be a strong tool for the rapid screening of multicomponent museum collections exhibiting off-gassing problems, before the pursuit of other more tedious analytical approaches. Additionally, the study reveals valuable insight into the characteristic volatile emission of historic medicinal, pharmaceutical, and cosmetic artifacts, increasing understanding of, and decision-making for, similar collections of objects. Eventually, it is hoped that this information can be used to inform mitigation strategies for the capture and reduction of VOCs in collections storage areas. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000659058300001 |
Publication Date |
2021-06-08 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1873-9318 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
3.184 |
Times cited |
|
Open Access |
Not_Open_Access |
|
|
Notes |
|
Approved |
Most recent IF: 3.184 |
|
|
Call Number |
UA @ admin @ c:irua:181923 |
Serial |
8129 |
|
Permanent link to this record |
|
|
|
|
Author |
Alvarez-Martin, A.; Kavich, G. |
|
|
Title |
SPME-GC–MS for the off-gassing analysis of a complex museum object |
Type |
A1 Journal article |
|
Year |
2021 |
Publication |
Microchemical Journal |
Abbreviated Journal |
Microchem J |
|
|
Volume |
167 |
Issue |
|
Pages |
106276 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp X-ray Imaging and Spectroscopy (AXIS) |
|
|
Abstract |
The identification of volatile organic compounds (VOCs) emitted by a complex museum object, composed of materials of different nature, has been optimized by solid-phase microextraction coupled to gas chromatography-mass spectrometry (SPME-GC–MS). The performance of two fiber coatings and four sampling times were tested and compared in order to define the best sampling conditions. The method allowed a fair extraction of volatile and semivolatile compounds emitted naturally by the object, without any type of accelerating aging. In addition, on-fiber derivatization was applied to improve the extraction efficiency and reduce the sampling time of harmful carboxylic acids emitted by the object. The results obtained are of prime importance to show the off-gassing activity of a valuable museum object in order to take further decisions related with its storage and display conditions. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000662640500001 |
Publication Date |
2021-04-21 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0026-265x; 0026-265x |
ISBN |
|
Additional Links |
UA library record; WoS full record |
|
|
Impact Factor |
3.034 |
Times cited |
|
Open Access |
Not_Open_Access |
|
|
Notes |
|
Approved |
Most recent IF: 3.034 |
|
|
Call Number |
UA @ admin @ c:irua:181924 |
Serial |
8577 |
|
Permanent link to this record |
|
|
|
|
Author |
Baij, L.; Liu, C.; Buijs, J.; Alvarez Martin, A.; Westert, D.; Raven, L.; Geels, N.; Noble, P.; Sprakel, J.; Keune, K. |
|
|
Title |
Understanding and optimizing Evolon® CR for varnish removal from oil paintings |
Type |
A1 Journal article |
|
Year |
2021 |
Publication |
Heritage science |
Abbreviated Journal |
|
|
|
Volume |
9 |
Issue |
1 |
Pages |
155-17 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp X-ray Imaging and Spectroscopy (AXIS) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2021-11-27 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2050-7445 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
Not_Open_Access |
|
|
Notes |
|
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ admin @ c:irua:183747 |
Serial |
8707 |
|
Permanent link to this record |
|
|
|
|
Author |
Janssens, K.; Vekemans, B.; Adams, F.; van Espen, P.; Mutsaers, P. |
|
|
Title |
Accurate evaluation of \mu-PIXE and \mu-XRF spectral data through iterative least squares fitting |
Type |
A1 Journal article |
|
Year |
1996 |
Publication |
Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms
T2 – 7th International Conference on Particle Induced X-ray Emission and Its Analytical Applications, MAY 26-30, 1995, Abano Terme, Italy |
Abbreviated Journal |
7th International Conference on Particle Induced X-ray Emission and Its Analytical Applications, MAY |
|
|
Volume |
109 |
Issue |
|
Pages |
179-185 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3) |
|
|
Abstract |
The integration of the nonlinear least squares X-ray spectrum evaluation progam AXIL. into a mu-PIXE and a mu-XRF setup is discussed. The use of the software when procesing data sets derived from biological and geological samples is described. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1996UV44400035 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0168-583x |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:95887 |
Serial |
5457 |
|
Permanent link to this record |
|
|
|
|
Author |
Kara De Maeijer, P.; Craeye, B.; Snellings, R.; Kazemi-Kamyab, H.; Loots, M.; Janssens, K.; Nuyts, G. |
|
|
Title |
Effect of ultra-fine fly ash on concrete performance and durability |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Construction And Building Materials |
Abbreviated Journal |
Constr Build Mater |
|
|
Volume |
263 |
Issue |
|
Pages |
120493-13 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Energy and Materials in Infrastructure and Buildings (EMIB) |
|
|
Abstract |
In the present study ultra-fine fly ash as a novel by-product obtained by a dry and closed separation process was investigated as cement replacement in concrete. The impact of ultra-fine fly ash on material properties was investigated following an upscaling as an approach considering paste, mortar and concrete properties. Two types of cement, Portland cement (CEMI) and slag cement (CEMIII), two types of ultra-fly ashes, one with particle size d90< 9.3lm (FA1) and second with d90< 4.6lm (FA2) were used.At paste- and mortar- level, cement was replaced at 0%, 15%, 25%, 35% and 50% with FA1 and FA2. At concrete- level, cement was replaced at 0%, 15% and 25% with different ratios of FA1 and FA2. The results at paste- and mortar- level showed that an increased fineness of the fly ash (FA2) contributes to better workability of the mix. For CEMI, the compressive strength of concrete with FA2 at 25% cement replacement was already equal to the reference 0% replacement concrete at the age of 28 days. For CEMIII, the compressive strength of concrete mix with FA1 with 15% and FA2 with 25% cement replacements reached the reference concrete value at the age of 91 days. Regarding the durability, replacing cement with ultra-fine fly ash (FA2) had a positive influence on the resistivity, chloride migration coefficient and alkali-silica reaction (ASR), and a negative influence on the carbonation resistance. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000582567100093 |
Publication Date |
2020-10-13 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0950-0618 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
7.4 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 7.4; 2020 IF: 3.169 |
|
|
Call Number |
UA @ admin @ c:irua:171815 |
Serial |
6498 |
|
Permanent link to this record |
|
|
|
|
Author |
Akbulut, S.; Krupinska, B.; Worobiec, A.; Čevik, U.; Taskin, H.; Van Grieken, R.; Samek, L.; Wiłkojć, E. |
|
|
Title |
Gross alpha and beta activities of airborne particulate samples from Wawel Royal Castle Museum in Cracow, Poland |
Type |
A1 Journal article |
|
Year |
2013 |
Publication |
Journal of radioanalytical and nuclear chemistry |
Abbreviated Journal |
|
|
|
Volume |
295 |
Issue |
2 |
Pages |
1567-1573 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP) |
|
|
Abstract |
Soils are complex mixtures of organic, inorganic materials, and metal compounds from anthropogenic sources. In order to identify the pollution sources, their magnitude and development, several X-ray analytical methods were applied in this study. The concentrations of 16 elements were determined in all the soil samples using energy dispersive X-ray fluorescence spectrometry. Soils of unknown origin were observed by scanning electron microscopy equipped with a Si(Li) X-ray detector using Monte Carlo simulation approach. The mineralogical analyses were carried out using X-ray diffraction spectrometry. Due to the correlations between heavy metals and oxide compounds, the samples were analyzed also by electron probe microanalyzer (EPMA) in order to have information about their oxide contents. On the other hand, soil pH and salinity levels were identified owing to their influence between heavy metal and soil-surface chemistry. Moreover, the geoaccumulation index (I geo) enables the assessment of contamination by comparing current and pre-industrial concentrations. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000313713300105 |
Publication Date |
2012-07-24 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0236-5731; 1588-2780 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:106763 |
Serial |
8012 |
|
Permanent link to this record |
|
|
|
|
Author |
Bottari, F.; Daems, E.; de Vries, A.-M.; Van Wielendaele, P.; Trashin, S.; Blust, R.; Sobott, F.; Madder, A.; Martins, J.C.; De Wael, K. |
|
|
Title |
Do aptamers always bind? The need for a multifaceted analytical approach when demonstrating binding affinity between aptamer and low molecular weight compounds |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Journal Of The American Chemical Society |
Abbreviated Journal |
J Am Chem Soc |
|
|
Volume |
142 |
Issue |
46 |
Pages |
jacs.0c08691-19630 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Medical Biochemistry |
|
|
Abstract |
In this manuscript, we compare different analytical methodologies to validate or disprove the binding capabilities of aptamer sequences. This was prompted by the lack of a universally accepted and robust quality control protocol for the characterization of aptamer performances coupled with the observation of independent yet inconsistent data sets in the literature. As an example, we chose three aptamers with a reported affinity in the nanomolar range for ampicillin, a β-lactam antibiotic, used as biorecognition elements in several detection strategies described in the literature. Application of a well-known colorimetric assay based on aggregation of gold nanoparticles (AuNPs) yielded conflicting results with respect to the original report. Therefore, ampicillin binding was evaluated in solution using isothermal titration calorimetry (ITC), native nano-electrospray ionization mass spectrometry (native nESI-MS), and 1H-nuclear magnetic resonance spectroscopy (1H NMR). By coupling the thermodynamic data obtained with ITC with the structural information on the binding event given by native nESI-MS and 1H NMR we could verify that none of the ampicillin aptamers show any specific binding with their intended target. The effect of AuNPs on the binding event was studied by both ITC and 1H NMR, again without providing positive evidence of ampicillin binding. To validate the performance of our analytical approach, we investigated two well-characterized aptamers for cocaine/quinine (MN4), chosen for its nanomolar range affinity, and l-argininamide (1OLD) to show the versatility of our approach. The results clearly indicate the need for a multifaceted analytical approach, to unequivocally establish the actual detection potential and performance of aptamers aimed at small organic molecules. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000592911000024 |
Publication Date |
2020-11-09 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0002-7863 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
15 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 15; 2020 IF: 13.858 |
|
|
Call Number |
UA @ admin @ c:irua:173136 |
Serial |
6488 |
|
Permanent link to this record |
|
|
|
|
Author |
Hofman, J.; Castanheiro, A.; Nuyts, G.; Joosen, S.; Spassov, S.; Blust, R.; De Wael, K.; Lenaerts, S.; Samson, R. |
|
|
Title |
Impact of urban street canyon architecture on local atmospheric pollutant levels and magneto-chemical PM10 composition : an experimental study in Antwerp, Belgium |
Type |
A1 Journal article |
|
Year |
2019 |
Publication |
The science of the total environment |
Abbreviated Journal |
Sci Total Environ |
|
|
Volume |
712 |
Issue |
712 |
Pages |
135534 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Sustainable Energy, Air and Water Technology (DuEL) |
|
|
Abstract |
As real-life experimental data on natural ventilation of atmospheric pollution levels in urban street canyons is still scarce and has proven to be complex, this study, experimentally evaluated the impact of an urban street canyon opening on local atmospheric pollution levels, during a 2-week field campaign in a typical urban street canyon in Antwerp, Belgium. Besides following up on atmospheric particulate matter (PM), ultrafine particles (UFPs) and black carbon (BC) levels, the magneto-chemical PM10 composition was quantified to identify contributions of specific elements in enclosed versus open street canyon sections. Results indicated no higher overall PM, UFP and BC concentrations at the enclosed site compared to the open site, but significant day-to-day variability between both monitoring locations, depending on the experienced wind conditions. On days with oblique wind regimes (4 out of 14), natural ventilation was observed at the open location while higher element contributions of Ca, Fe, Co, Ni, Cu, Zn and Sr were exhibited at the enclosed location. Magnetic properties correlated with the PM10 filter loading, and elemental content of Fe, Cr, Mn and Ti. Magnetic bivariate ratios identified finel-grained magnetite carriers with grain sizes below 0.1 μm, indicating similar magnetic source contributions at both monitoring locations. Our holistic approach, combining atmospheric monitoring with magneto-chemical PM characterization has shown the complex impact of real-life wind flow regimes, different source contributions and local traffic dynamics on the resulting pollutant concentrations and contribute to a better understanding on the urban ventilation processes of atmospheric pollution. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000512369600078 |
Publication Date |
2019-11-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0048-9697 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
4.9 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 4.9 |
|
|
Call Number |
UA @ admin @ c:irua:165459 |
Serial |
5654 |
|
Permanent link to this record |