|
Records |
Links |
|
Author |
Pilehvar, S.; Gielkens, K.; Trashin, S.A.; Dardenne, F.; Blust, R.; De Wael, K. |
![goto web page (via DOI) doi](http://nano.uantwerpen.be/nanorefs/img/doi.gif)
|
|
Title |
(Electro)sensing of phenicol antibiotics : a review |
Type |
A1 Journal article |
|
Year |
2016 |
Publication |
Critical reviews in food science and nutrition |
Abbreviated Journal |
Crit Rev Food Sci |
|
|
Volume |
56 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
14 |
Pages |
2416-2429 |
|
|
Keywords |
A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The presence of residues from frequent antibiotic use in animal feed can cause serious health risks by contaminating products for human consumption such as meat and milk. The present article gives an overview of the electrochemical methods developed for the detection of phenicol antibiotic residues (chloramphenicol, thiamphenicol, and florfenicol) in different kinds of foodstuffs. Electrochemical sensors based on different biomolecules and nanomaterials are described. The detection limit of various developed methods with their advantages and disadvantage will be highlighted. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000382757200015 |
Publication Date |
2015-04-02 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1040-8398 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
6.077 |
Times cited |
13 |
Open Access |
|
|
|
Notes |
; The authors are highly thankful for the University of Antwerp Grants (DOCPRO/ IWS). ; |
Approved |
Most recent IF: 6.077 |
|
|
Call Number |
UA @ admin @ c:irua:125663 |
Serial |
5585 |
|
Permanent link to this record |
|
|
|
|
Author |
Vermeulen, M.; Janssens, K.; Sanyova, J.; Rahemi, V.; McGlinchey, C.; De Wael, K. |
![goto web page url](http://nano.uantwerpen.be/nanorefs/img/www.gif)
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Assessing the stability of arsenic sulfide pigments and influence of the binding media on their degradation by means of spectroscopic and electrochemical techniques |
Type |
A1 Journal article |
|
Year |
2018 |
Publication |
Microchemical journal |
Abbreviated Journal |
Microchem J |
|
|
Volume |
138 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
138 |
Pages |
82-91 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
In this paper, we used the semiconducting and lightfastness properties of synthetic and mineral arsenic sulfide pigments to study their stability by means of electrochemical and microfadometric techniques. A combination of these techniques shows that in the early stage of the degradation process, amorphous arsenic sulfides are more stable than both crystalline forms, while upon longer exposure time, amorphous pigments will fade more than both mineral pigments, making it less suitable. While the stability study was carried out on unbound pigments, the influence of the organic binder on the relative degradation of the arsenic sulfide pigments was investigated through a multi-analytical approach on pigment/binder mock-up paint samples. For this purpose, the formation of arsenic trioxide was assessed by micro Fourier transform infrared (μ-FTIR) spectroscopy while the influence of the binder on the formation of sulfates was studied by means of synchrotron radiation X-ray near edge structure (μ-XANES). Both techniques elucidate a higher stability of all pigments in gum arabic while the use of egg yolk as binder leads to the most degradation, most likely due to its sulfur-rich composition. In the context of the degradation of arsenic sulfide pigments, other binders such as animal glue, egg white or linseed oil show an intermediate impact. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000428103000010 |
Publication Date |
2018-01-06 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0026-265x; 0026-265x |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
3.034 |
Times cited |
4 |
Open Access |
|
|
|
Notes |
; This research is made possible with the support of the Belgian Science Policy Office (BELSPO, Brussels) through the research program Science for a Sustainable Development – SDD, “Long-term role and fate of metal-sulfides in painted works of art – S2ART” (grant number SD/RI/04A). We gratefully acknowledge Megane Willems (Institut Paul-Lambin) for her help with mu-FFIR analyses and realization of the mock-up paint samples. We acknowledge the Paul Scherrer Institut, Villigen, Switzerland for provision of synchrotron radiation beamtime at beamline Phoenix of the SLS. ; |
Approved |
Most recent IF: 3.034 |
|
|
Call Number |
UA @ admin @ c:irua:150149 |
Serial |
5482 |
|
Permanent link to this record |
|
|
|
|
Author |
Neven, L.; Barich, H.; Ching, H.Y.V.; Khan, S.U.; Colomier, C.; Patel, H.H.; Gorun, S.M.; Verbruggen, S.; Van Doorslaer, S.; De Wael, K. |
![goto web page url](http://nano.uantwerpen.be/nanorefs/img/www.gif)
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Correlation between the fluorination degree of perfluorinated zinc phthalocyanines, their singlet oxygen generation ability, and their photoelectrochemical response for phenol sensing |
Type |
A1 Journal article |
|
Year |
2022 |
Publication |
Analytical chemistry |
Abbreviated Journal |
Anal Chem |
|
|
Volume |
94 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
13 |
Pages |
5221-5230 |
|
|
Keywords |
A1 Journal article; Organic synthesis (ORSY); Sustainable Energy, Air and Water Technology (DuEL); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab) |
|
|
Abstract |
Electron-withdrawing perfluoroalkyl peripheral groups grafted on phthalocyanine (Pc) macrocycles improve their single-site isolation, solubility, and resistance to self-oxidation, all beneficial features for catalytic applications. A high degree of fluorination also enhances the reducibility of Pcs and could alter their singlet oxygen (1O2) photoproduction. The ethanol/toluene 20:80 vol % solvent mixture was found to dissolve perfluorinated FnPcZn complexes, n = 16, 52, and 64, and minimize the aggregation of the sterically unencumbered F16PcZn. The 1O2 production ability of FnPcZn complexes was examined using 9,10-dimethylanthracene (DMA) and 2,2,6,6-tetramethylpiperidine (TEMP) in combination with UV–vis and electron paramagnetic resonance (EPR) spectroscopy, respectively. While the photoreduction of F52PcZn and F64PcZn in the presence of redox-active TEMP lowered 1O2 production, DMA was a suitable 1O2 trap for ranking the complexes. The solution reactivity was complemented by solid-state studies via the construction of photoelectrochemical sensors based on TiO2-supported FnPcZn, FnPcZn|TiO2. Phenol photo-oxidation by 1O2, followed by its electrochemical reduction, defines a redox cycle, the 1O2 production having been found to depend on the value of n and structural features of the supported complexes. Consistent with solution studies, F52PcZn was found to be the most efficient 1O2 generator. The insights on reactivity testing and structural–activity relationships obtained may be useful for designing efficient and robust sensors and for other 1O2-related applications of FnPcZn. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000786254500002 |
Publication Date |
2022-03-22 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2700; 5206-882x |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
7.4 |
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
|
Approved |
Most recent IF: 7.4 |
|
|
Call Number |
UA @ admin @ c:irua:187522 |
Serial |
7141 |
|
Permanent link to this record |
|
|
|
|
Author |
Truta, F.; Drăgan, A.-M.; Tertis, M.; Parrilla, M.; Slosse, A.; Van Durme, F.; De Wael, K.; Cristea, C. |
![goto web page (via DOI) doi](http://nano.uantwerpen.be/nanorefs/img/doi.gif)
|
|
Title |
Electrochemical rapid detection of methamphetamine from confiscated samples using a graphene-based printed platform |
Type |
A1 Journal article |
|
Year |
2023 |
Publication |
Sensors |
Abbreviated Journal |
|
|
|
Volume |
23 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
13 |
Pages |
6193-18 |
|
|
Keywords |
A1 Journal article; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab) |
|
|
Abstract |
Methamphetamine (MAP) is a highly addictive and illegal stimulant drug that has a significant impact on the central nervous system. Its detection in biological and street samples is crucial for various organizations involved in forensic medicine, anti-drug efforts, and clinical diagnosis. In recent years, nanotechnology and nanomaterials have played a significant role in the development of analytical sensors for MAP detection. In this study, a fast, simple, and cost-effective electrochemical sensor is presented that is used for the sensitive detection of MAP in confiscated street samples with a complex matrix. The optimized screen-printed sensor based on a carbon working electrode modified with graphene demonstrated an excellent limit of detection, good sensitivity, and a wide dynamic range (1–500 μM) for the target illicit drug both for standard solutions and real samples (seized samples, tap water, and wastewater samples). It can detect MAP at concentrations as low as 300 nM in real samples. This limit of detection is suitable for the rapid preliminary screening of suspicious samples in customs, ports, airports, and on the street. Furthermore, the sensor exhibits a good recovery rate, indicating its reliability and repeatability. This quality is crucial for ensuring consistent and accurate results during screening processes. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
001033277900001 |
Publication Date |
2023-07-07 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1424-8220 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
|
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ admin @ c:irua:198181 |
Serial |
8857 |
|
Permanent link to this record |
|
|
|
|
Author |
Florea, A.; Schram, J.; De Jong, M.; Eliaerts, J.; Van Durme, F.; Kaur, B.; Samyn, N.; De Wael, K. |
![goto web page (via DOI) doi](http://nano.uantwerpen.be/nanorefs/img/doi.gif)
|
|
Title |
Electrochemical strategies for adulterated heroin samples |
Type |
A1 Journal article |
|
Year |
2019 |
Publication |
Analytical chemistry |
Abbreviated Journal |
Anal Chem |
|
|
Volume |
91 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
12 |
Pages |
7920-7928 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Electrochemical strategies to selectively detect heroin in street samples without the use of complicated electrode modifications were developed for the first time. For this purpose, heroin, mixing agents (adulterants, cutting agent, and impurities), and their binary mixtures were subjected to square wave voltammetry measurements at bare graphite electrodes at pH 7.0 and pH 12.0, in order to elucidate the unique electrochemical fingerprint of heroin and mixing agents as well as possible interferences or reciprocal influences. Adjusting the pH from pH 7.0 to pH 12.0 allowed a more accurate detection of heroin in the presence of most common mixing agents. Furthermore, the benefit of introducing a preconditioning step prior to running square wave voltammetry on the electrochemical fingerprint enrichment was explored. Mixtures of heroin with other drugs (cocaine, 3,4-methylenedioxymethamphetamine, and morphine) were also tested to explore the possibility of their discrimination and simultaneous detection. The feasibility of the proposed electrochemical strategies was tested on realistic heroin street samples from forensic cases, showing promising results for fast, on-site detection tools of drugs of abuse. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000472682000056 |
Publication Date |
2019-05-30 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2700; 5206-882x |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
6.32 |
Times cited |
2 |
Open Access |
|
|
|
Notes |
; This project has received funding from the European Union's Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie Grant Agreement No. 753223 Narcoreader. The authors also acknowledge IOF (UAntwerp) and Belspo for financial support. ; |
Approved |
Most recent IF: 6.32 |
|
|
Call Number |
UA @ admin @ c:irua:160061 |
Serial |
5596 |
|
Permanent link to this record |
|
|
|
|
Author |
Tilleman, L.; De Henau, S.; Pauwels, M.; Nagy, N.; Pintelon, I.; Braeckman, B.P.; De Wael, K.; Van Doorslaer, S.; Adriaensen, D.; Timmermans, J.-P.; Moens, L.; Dewilde, S. |
![goto web page (via DOI) doi](http://nano.uantwerpen.be/nanorefs/img/doi.gif)
|
|
Title |
An N-myristoylated globin with a redox-sensing function that regulates the defecation cycle in Caenorhabditis elegans |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
PLoS ONE |
Abbreviated Journal |
Plos One |
|
|
Volume |
7 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
12 |
Pages |
e48768-9 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Globins occur in all kingdoms of life where they fulfill a wide variety of functions. In the past they used to be primarily characterized as oxygen transport/storage proteins, but since the discovery of new members of the globin family like neuroglobin and cytoglobin, more diverse and complex functions have been assigned to this heterogeneous family. Here we propose a function for a membrane-bound globin of C. elegans, GLB-26. This globin was predicted to be myristoylated at its N-terminus, a post-translational modification only recently described in the globin family. In vivo, this globin is found in the membrane of the head mesodermal cell and in the tail stomato-intestinal and anal depressor muscle cells. Since GLB-26 is almost directly oxidized when exposed to oxygen, we postulate a possible function as electron transfer protein. Phenotypical studies show that GLB-26 takes part in regulating the length of the defecation cycle in C. elegans under oxidative stress conditions. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000313236200008 |
Publication Date |
2012-12-12 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1932-6203 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.806 |
Times cited |
6 |
Open Access |
|
|
|
Notes |
; SDH is a Ph.D. fellow of the Fund for Scientific Research (FWO). Financial support to SD and LM was provided by the University of Antwerp (BOF UA TOP 2006) and to SD, LM, BPB, by FWO project G.0247.09. The UltraVIEW VoX spinning disk confocal microscope was purchased with support of the Hercules Foundation (Hercules Type 1: AUHA 09/001). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. ; |
Approved |
Most recent IF: 2.806; 2012 IF: 3.730 |
|
|
Call Number |
UA @ admin @ c:irua:102591 |
Serial |
5741 |
|
Permanent link to this record |
|
|
|
|
Author |
Florea, A.; De Jong, M.; De Wael, K. |
![goto web page url](http://nano.uantwerpen.be/nanorefs/img/www.gif)
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Electrochemical strategies for the detection of forensic drugs |
Type |
A1 Journal article |
|
Year |
2018 |
Publication |
Current opinion in electrochemistry |
Abbreviated Journal |
|
|
|
Volume |
11 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
11 |
Pages |
34-40 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Illicit drugs consumption and trafficking is spread worldwide and remains an increasing challenge for local authorities. Forensic drugs and their metabolites are released into wastewaters due to human excretion after illegal consumption of drugs and occasionally due to disposal of clandestine laboratory wastes into sewage systems, being recently classified as the latest group of emerging pollutants. Hence, it is essential to have efficient and accurate methods to detect these type of compounds in seized street samples, biological fluids and wastewaters in order to reduce and prevent trafficking and consumption and negative effects on aquatic systems. Electrochemical strategies offer a fast, portable, low-cost and accurate alternative to chromatographic and spectrometric methods, for the analysis of forensic drugs and metabolites in different matrices. Recent electrochemical strategies applied to the detection of illicit drugs in wastewaters, biological fluids and street samples are presented in this review, together with the impact of drug consumption on the environment. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000453710900007 |
Publication Date |
2018-07-21 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2451-9103; 2451-9111 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
7 |
Open Access |
|
|
|
Notes |
; This project has received funding from the European Union's Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie Grant Agreement No. 753223 Narcoreader. The authors also acknowledge financial support from BELSPO, IOF-SBO and UAntwerp. ; |
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ admin @ c:irua:152366 |
Serial |
5597 |
|
Permanent link to this record |
|
|
|
|
Author |
De Jong, M.; Florea, A.; Eliaerts, J.; Van Durme, F.; Samyn, N.; De Wael, K. |
![goto web page (via DOI) doi](http://nano.uantwerpen.be/nanorefs/img/doi.gif)
|
|
Title |
Tackling poor specificity of cocaine color tests by electrochemical strategies |
Type |
A1 Journal article |
|
Year |
2018 |
Publication |
Analytical chemistry |
Abbreviated Journal |
Anal Chem |
|
|
Volume |
90 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
11 |
Pages |
6811-6819 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
This paper presents electrochemical strategies for the fast screening of cocaine and most common cutting agents found in seized drug samples. First, a study on the performance of Scott color tests on cocaine and a wide range of cutting agents is described. The cutting agents causing false positive or false negative results when in mixture with cocaine are identified. To overcome the lack of specificity of color tests, we further propose a fast screening strategy by means of square wave voltammetry on disposable graphite screen printed electrodes, which reveals the unique fingerprint of cocaine and cutting agents. By employing a forward and backward scan and by a dual pH strategy, we enrich the electrochemical fingerprint and enable the simultaneous detection of cocaine and cutting agents. The effectiveness of the developed strategies was tested for the detection of cocaine in seized cocaine samples and compared with the color tests. Moreover, we prove the usefulness of square wave voltammetry for predicting possible interfering agents in color tests, based on the reduction peak of cobalt thiocyanate. The developed electrochemical strategies allow for a quick screening of seized cocaine samples resulting in a selective identification of drugs and cutting agents. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000434893200066 |
Publication Date |
2018-05-09 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2700; 5206-882x |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
6.32 |
Times cited |
7 |
Open Access |
|
|
|
Notes |
; This project has received funding from the European Union's Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie Grant Agreement No. 753223 Narcoreader. This work was also supported by Grants BR/314 /PI/APTADRU and IOF-SBO. ; |
Approved |
Most recent IF: 6.32 |
|
|
Call Number |
UA @ admin @ c:irua:151316 |
Serial |
5867 |
|
Permanent link to this record |
|
|
|
|
Author |
De Wael, K.; Daems, D.; Van Camp, G.; Nagels, L.J. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
The use of potentiometric sensors to study (bio)molecular interactions |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
Analytical chemistry |
Abbreviated Journal |
Anal Chem |
|
|
Volume |
84 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
11 |
Pages |
4921-4927 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Potentiometric sensors were used to study molecular interactions in liquid environments, with sensorgram methodology. This is demonstrated with a lipophilic rubber-, and with a collagen based hydrogel sensor coating. The investigated molecules were promazine and tartaric acid respectively. The sensors were placed in a hydrodynamic wall jet system for the recording of sensorgrams. mV sensor responses were first converted to a signal, expressing the concentration of adsorbed organic ions. Using a linearization method, a pseudo first order kinetic model of adsorption was shown to fit the experimental results perfectly. Kass, kon and koff values were calculated.. The technique can be used over 4 decades of concentration, and it is very sensitive to low MW compounds as well as to multiply charged large biomolecules. This study is the first to demonstrate the application of potentiometric sensors as an alternative and complement to SPR methods. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000304783100041 |
Publication Date |
2012-04-28 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2700; 5206-882x |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
6.32 |
Times cited |
10 |
Open Access |
|
|
|
Notes |
; Financial support for this work was provided by the University of Antwerp by granting D.D. a BOF interdisciplinary research project. We thank J. Everaert for his help in interpreting the results. K.D.W. and D.D. contributed equally to this work. ; |
Approved |
Most recent IF: 6.32; 2012 IF: 5.695 |
|
|
Call Number |
UA @ admin @ c:irua:97520 |
Serial |
5898 |
|
Permanent link to this record |
|
|
|
|
Author |
Blidar, A.; Trashin, S.; Carrion, E.N.; Gorun, S.M.; Cristea, C.; De Wael, K. |
![goto web page url](http://nano.uantwerpen.be/nanorefs/img/www.gif)
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Enhanced photoelectrochemical detection of an analyte triggered by its concentration by a singlet oxygen-generating fluoro photosensitizer |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Acs Sensors |
Abbreviated Journal |
Acs Sensors |
|
|
Volume |
5 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
11 |
Pages |
3501-3509 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The use of a photocatalyst (photosensitizer) which produces singlet oxygen instead of enzymes for oxidizing analytes creates opportunities for designing cost-efficient and sensitive photoelectrochemical sensors. We report that perfluoroisopropyl-substituted zinc phthalocyanine (F64PcZn) interacts specifically with a complex phenolic compound, the antibiotic rifampicin (RIF), but not with hydroquinone or another complex phenolic compound, the antibiotic doxycycline. The specificity is imparted by the selective preconcentration of RIF in the photocatalytic layer, as revealed by electrochemical and optical measurements, complemented by molecular modeling that confirms the important role of a hydrophobic cavity formed by the iso-perfluoropropyl groups of the photocatalyst. The preconcentration effect favorably enhances the RIF photoelectrochemical detection limit as well as sensitivity to nanomolar (ppb) concentrations, LOD = 7 nM (6 ppb) and 2.8 A.M-1.cm(-2), respectively. The selectivity to RIF, retained in the photosensitizer layer, is further enhanced by the selective removal of all unretained phenols via simple washing of the electrodes with pure buffer. The utility of the sensor for analyzing municipal wastewater was demonstrated. This first demonstration of enhanced selectivity and sensitivity due to intrinsic interactions of a molecular photocatalyst (photosensitizer) with an analyte, without use of a biorecognition element, may allow the design of related, robust, simple, and viable sensors. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000595550100021 |
Publication Date |
2020-10-29 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2379-3694 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
8.9 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 8.9; 2020 IF: NA |
|
|
Call Number |
UA @ admin @ c:irua:176057 |
Serial |
7913 |
|
Permanent link to this record |
|
|
|
|
Author |
Borhani, A.H.; Berghmans, H.; Trashin, S.; De Wael, K.; Fago, A.; Moens, L.; Habibi-Rezaei, M.; Dewilde, S. |
![goto web page (via DOI) doi](http://nano.uantwerpen.be/nanorefs/img/doi.gif)
|
|
Title |
Kinetic properties and heme pocket structure of two domains of the polymeric hemoglobin of Artemia in comparison with the native molecule |
Type |
A1 Journal article |
|
Year |
2015 |
Publication |
Biochimica et biophysica acta : proteins and proteomics |
Abbreviated Journal |
Bba-Proteins Proteom |
|
|
Volume |
1854 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
10a |
Pages |
1307-1316 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
In this project, we studied some physicochemical properties of two different globin domains of the polymeric hemoglobin of the brine shrimp Artemia salina and compared them with those of the native molecule. Two domains (AsHbC1D1 and AsHbC1D5) were cloned and expressed in BL21(DE3)pLysS strain of Escherichiacoli. The recombinant proteins as well as the native hemoglobin (AfHb) were purified from bacteria and frozen Artemia, respectively by standard chromatographic methods and assessed by SDS-PAGE. The heme environment of these proteins was studied by optical spectroscopy and ligand-binding kinetics (e.g. CO association and O2 binding affinity) were measured for the two recombinant proteins and the native hemoglobin. This indicates that the CO association rate for AsHbC1D1 is higher than that of AsHbC1D5 and AfHb, while the calculated P50 value for AsHbC1D1 is lower than that of AsHbC1D5 and AfHb. The geminate and bimolecular rebinding parameters indicate a significant difference between both domains. Moreover, EPR results showed that the heme pocket in AfHb is in a more closed conformation than the heme pocket in myoglobin. Finally, the reduction potential of − 0.13 V versus the standard hydrogen electrode was determined for AfHb by direct electrochemical measurements. It is about 0.06 V higher than the potential of the single domain AsHbC1D5. This work shows that each domain in the hemoglobin of Artemia has different characteristics of ligand binding. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000362307500008 |
Publication Date |
2015-05-22 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1570-9639 |
ISBN |
|
Additional Links |
UA library record; WoS full record |
|
|
Impact Factor |
2.773 |
Times cited |
|
Open Access |
|
|
|
Notes |
; This work was supported by the general grant for visiting scholar of the Ministry of Science, Research and Technology of I. R. Iran and by the University of Antwerp. ; |
Approved |
Most recent IF: 2.773; 2015 IF: 2.747 |
|
|
Call Number |
UA @ admin @ c:irua:125909 |
Serial |
5683 |
|
Permanent link to this record |
|
|
|
|
Author |
Meysman, F.J.R.; Cornelissen, R.; Trashin, S.; Bonne, R.; Hidalgo-Martinez, S.; van der Veen, J.; Blom, C.J.; Karman, C.; Hou, J.-L.; Eachambadi, R.T.; Geelhoed, J.S.; De Wael, K.; Beaumont, H.J.E.; Cleuren, B.; Valcke, R.; van der Zant, H.S.J.; Boschker, H.T.S.; Manca, J.V. |
![goto web page (via DOI) doi](http://nano.uantwerpen.be/nanorefs/img/doi.gif)
|
|
Title |
A highly conductive fibre network enables centimetre-scale electron transport in multicellular cable bacteria |
Type |
A1 Journal article |
|
Year |
2019 |
Publication |
Nature communications |
Abbreviated Journal |
Nat Commun |
|
|
Volume |
10 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
10 |
Pages |
4120 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Biological electron transport is classically thought to occur over nanometre distances, yet recent studies suggest that electrical currents can run along centimetre-long cable bacteria. The phenomenon remains elusive, however, as currents have not been directly measured, nor have the conductive structures been identified. Here we demonstrate that cable bacteria conduct electrons over centimetre distances via highly conductive fibres embedded in the cell envelope. Direct electrode measurements reveal nanoampere currents in intact filaments up to 10.1 mm long (>2000 adjacent cells). A network of parallel periplasmic fibres displays a high conductivity (up to 79 S cm(-1)), explaining currents measured through intact filaments. Conductance rapidly declines upon exposure to air, but remains stable under vacuum, demonstrating that charge transfer is electronic rather than ionic. Our finding of a biological structure that efficiently guides electrical currents over long distances greatly expands the paradigm of biological charge transport and could enable new bio-electronic applications. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000485216900006 |
Publication Date |
2019-09-11 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2041-1723 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
12.124 |
Times cited |
10 |
Open Access |
|
|
|
Notes |
; This research was financially supported by the European Research Council under the European Union's Seventh Framework Programme (FP/2007-2013) through ERC Grant 306933 (F.J.R.M.), the Research Foundation Flanders (FWO project grant G031416N), and the Netherlands Organisation for Scientific Research (VICI grant 016.VICI.170.072 to F.J.R.M.). H.J.E.B., C.J.B. and H.S.J.Z. were supported by the Netherlands Organisation for Scientific Research (NWO/OCW), as part of the Frontiers of Nanoscience program. R.B. is supported by an 'aspirant' grant from Research Foundation Flanders (FWO). We thank Laurine Burdorf (UAntwerpen) for help with Thiothrix cultivation, Marlies Nijemeisland (Faculty of Aerospace, TU Delft) for assistance with Raman microscopy, and Jan D'Haen (UHasselt) and Renaat Dasseville (UGent) for help with EM imaging. ; |
Approved |
Most recent IF: 12.124 |
|
|
Call Number |
UA @ admin @ c:irua:162795 |
Serial |
5451 |
|
Permanent link to this record |
|
|
|
|
Author |
Bottari, F.; Blust, R.; De Wael, K. |
![goto web page (via DOI) doi](http://nano.uantwerpen.be/nanorefs/img/doi.gif)
|
|
Title |
Bio(inspired) strategies for the electro-sensing of β-lactam antibiotics |
Type |
A1 Journal article |
|
Year |
2018 |
Publication |
Current opinion in electrochemistry |
Abbreviated Journal |
|
|
|
Volume |
10 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
10 |
Pages |
143-148 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The dire previsions of the WHO on the so-called “post-antibiotic era” and the continuous and global rise of anti-microbial resistance, spurs our research community to find better ways to fight these threats. In light of this severe threat to human health many attempts have been made to develop efficient methods to detect antibiotic residues in different streams. The use of electrochemistry seems an inviting approach for on-site and fast monitoring. In this critical review, recent developments in the field of (bio) electro-sensing of 19-lactam antibiotics will be presented, with a focus on aptamers and molecularly imprinted polymers, the two main promises of a new generation of biosensors, yet to be fulfilled. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000442800000022 |
Publication Date |
2018-05-24 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2451-9103; 2451-9111 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
15 |
Open Access |
|
|
|
Notes |
; This work was financially supported by the University of Antwerp (BOF) and the Research Foundation – Flanders (FWO). ; |
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ admin @ c:irua:153744 |
Serial |
5488 |
|
Permanent link to this record |
|
|
|
|
Author |
't Hart, L.; Storme, P.; Anaf, W.; Nuyts, G.; Vanmeert, F.; Dorriné, W.; Janssens, K.; De Wael, K.; Schalm, O. |
![goto web page url](http://nano.uantwerpen.be/nanorefs/img/www.gif)
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Monitoring the impact of the indoor air quality on silver cultural heritage objects using passive and continuous corrosion rate assessments |
Type |
A1 Journal article |
|
Year |
2016 |
Publication |
Applied physics A : materials science & processing |
Abbreviated Journal |
Appl Phys A-Mater |
|
|
Volume |
122 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
10 |
Pages |
923-10 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES) |
|
|
Abstract |
There is a long tradition in evaluating industrial atmospheres by measuring the corrosion rate of exposed metal coupons. The heritage community also uses this method, but the interpretation of the corrosion rate often lacks clarity due to the low corrosivity in indoor museum environments. This investigation explores the possibilities and drawbacks of different silver corrosion rate assessments. The corrosion rate is determined by three approaches: (1) chemical characterization of metal coupons using analytical techniques such as electrochemical measurements, SEM-EDX, XRD, and µ-Raman spectroscopy, (2) continuous corrosion monitoring methods based on electrical resistivity loss of a corroding nm-sized metal wire and weight gain of a corroding silver coated quartz crystal, and (3) characterization of the visual degradation of the metal coupons. This study confirms that subtle differences in corrosivity between locations inside a museum can be determined on condition that the same corrosion rate assessment is used. However, the impact of the coupon orientation with respect to the prevailing direction of air circulation can be substantially larger than the impact of the coupon location. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000384753800053 |
Publication Date |
2016-09-28 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0947-8396 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.455 |
Times cited |
3 |
Open Access |
|
|
|
Notes |
; This research has been sponsored by the Belgian Federal Public Planning Service Science Policy (BELSPO) under Project Number BR/132/A6/AIRCHECQ. In this project an innovative monitoring kit is developed that continuously and simultaneously measures both environmental parameters and material behaviour, enabling the study of the cause-effect relationships. The Quanta 250 FEG microscope at the University of Antwerp was funded by the Hercules foundation of the Flemish Government. ; |
Approved |
Most recent IF: 1.455 |
|
|
Call Number |
UA @ admin @ c:irua:135511 |
Serial |
5733 |
|
Permanent link to this record |
|
|
|
|
Author |
Eliaerts, J.; Dardenne, P.; Meert, N.; Van Durme, F.; Samyn, N.; Janssens, K.; De Wael, K. |
![goto web page (via DOI) doi](http://nano.uantwerpen.be/nanorefs/img/doi.gif)
|
|
Title |
Rapid classification and quantification of cocaine in seized powders with ATR-FTIR and chemometrics |
Type |
A1 Journal article |
|
Year |
2017 |
Publication |
Drug testing and analysis |
Abbreviated Journal |
Drug Test Anal |
|
|
Volume |
9 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
10 |
Pages |
1480-1489 |
|
|
Keywords |
A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Traditionally, fast screening for the presence of cocaine in unknown powders is performed by means of colour tests. The major drawbacks of these tests are subjective colour evaluation depending on the operator (50 shades of blue) and a lack of selectivity. An alternative fast screening technique is Fourier Transform InfraRed (FTIR) spectrometry. This technique provides spectra that are difficult to interpret without specialized expertise and showing a lack of sensitivity for the detection of cocaine in mixtures. To overcome these limitations, a portable FTIR spectrometer using Attenuated Total Reflectance (ATR) sampling was combined with a multivariate technique, called Support Vector Machines (SVM). Representative street drug powders (n = 482), seized during the period January 2013 to July 2015, and reference powders (n = 33) were used to build and validate a classification model (n = 515) and a quantification model (n = 378). Both models were compared with the conventional chromatographic techniques. The SVM classification model showed a high sensitivity, specificity and efficiency (99%). The SVM quantification model determined cocaine content with a root mean squared error of prediction (RMSEP) of 6% calculated over a wide working range from 4 to 99 w%. In conclusion, the developed models resulted in a clear output (cocaine detected or cocaine not detected) and a reliable estimation of the cocaine content in a wide variety of mixtures. The ATR-FTIR technique combined with SVM is a straightforward, user-friendly and fast approach for routine classification and quantification of cocaine in seized powders. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000413685200001 |
Publication Date |
2016-12-17 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1942-7603; 1942-7611 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
3.469 |
Times cited |
9 |
Open Access |
|
|
|
Notes |
; ; |
Approved |
Most recent IF: 3.469 |
|
|
Call Number |
UA @ admin @ c:irua:139483 |
Serial |
5799 |
|
Permanent link to this record |
|
|
|
|
Author |
Geerlings, N.M.J.; Karman, C.; Trashin, S.; As, K.S.; Kienhuis, M.V.M.; Hidalgo-Martinez, S.; Vasquez-Cardenas, D.; Boschker, H.T.S.; De Wael, K.; Middelburg, J.J.; Polerecky, L.; Meysman, F.J.R. |
![goto web page (via DOI) doi](http://nano.uantwerpen.be/nanorefs/img/doi.gif)
|
|
Title |
Division of labor and growth during electrical cooperation in multicellular cable bacteria |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Proceedings Of The National Academy Of Sciences Of The United States Of America |
Abbreviated Journal |
P Natl Acad Sci Usa |
|
|
Volume |
117 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
10 |
Pages |
5478-5485 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Multicellularity is a key evolutionary innovation, leading to coordinated activity and resource sharing among cells, which generally occurs via the physical exchange of chemical compounds. However, filamentous cable bacteria display a unique metabolism in which redox transformations in distant cells are coupled via long-distance electron transport rather than an exchange of chemicals. This challenges our understanding of organismal functioning, as the link among electron transfer, metabolism, energy conservation, and filament growth in cable bacteria remains enigmatic. Here, we show that cells within individual filaments of cable bacteria display a remarkable dichotomy in biosynthesis that coincides with redox zonation. Nanoscale secondary ion mass spectrometry combined with 13 C (bicarbonate and propionate) and 15 N-ammonia isotope labeling reveals that cells performing sulfide oxidation in deeper anoxic horizons have a high assimilation rate, whereas cells performing oxygen reduction in the oxic zone show very little or no label uptake. Accordingly, oxygen reduction appears to merely function as a mechanism to quickly dispense of electrons with little to no energy conservation, while biosynthesis and growth are restricted to sulfide-respiring cells. Still, cells can immediately switch roles when redox conditions change, and show no differentiation, which suggests that the “community service” performed by the cells in the oxic zone is only temporary. Overall, our data reveal a division of labor and electrical cooperation among cells that has not been seen previously in multicellular organisms. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000519530400054 |
Publication Date |
2020-02-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0027-8424; 1091-6490 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
11.1 |
Times cited |
6 |
Open Access |
|
|
|
Notes |
; We thank Arnold van Dijk for helping with the GasBench isotope ratio mass spectrometry analysis. N.M.J.G. is the recipient of a Ph.D. scholarship for teachers from the Netherlands Organisation for Scientific Research (NWO) in the Netherlands (grant 023.005.049). K.S.A. received financial support from the Olaf Schuiling fund. F.J.R.M. was financially supported by the Research Foundation Flanders (FWO) via grant G043119N, and the Netherlands Organization for Scientific Research (VICI grant 016.VICI.170.072). J.J.M. was supported by the Ministry of Education via the Netherlands Earth System Science Centre. The NanoSIMS facility was partly supported by an NWO large infrastructure subsidy to J.J.M. (175.010.2009.011). ; |
Approved |
Most recent IF: 11.1; 2020 IF: 9.661 |
|
|
Call Number |
UA @ admin @ c:irua:166452 |
Serial |
6487 |
|
Permanent link to this record |
|
|
|
|
Author |
Krupińska, B.; Worobiec, A.; Rotondo, G.G.; Novaković, V.; Kontozova, V.; Ro, C.-U.; Van Grieken, R.; De Wael, K. |
![goto web page (via DOI) doi](http://nano.uantwerpen.be/nanorefs/img/doi.gif)
|
|
Title |
Assessment of the air quality (NO2, SO2, O3 and particulate matter) in the Plantin-Moretus Museum/Print Room in Antwerp, Belgium, in different seasons of the year |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
Microchemical journal |
Abbreviated Journal |
Microchem J |
|
|
Volume |
102 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
1 |
Pages |
49-53 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP) |
|
|
Abstract |
The Plantin-Moretus Museum/Print Room in Antwerp, Belgium, gathers one of the most precious collections of typographical material and old printed books in the world. Rich decorations of this former printing-house and the history of the building itself underline its uniqueness. The cultural heritage (CH) objects collected in the museum, in particular books and manuscripts are vulnerable to the atmospheric pollution and can be irreversibly damaged. To assess the air quality inside the museum, four consecutive sampling campaigns were performed in each season of the year. The gas monitoring of nitrogen dioxide (NO2), sulphur dioxide (SO2) and ozone (O3) was carried out outside the building, in galleries and in showcases by means of using diffusive samplers. The particulate matter (PM) was collected in bulk form and as single particles and then analysed with use of energy dispersive X-ray fluorescence (EDXRF) and electron probe micro-analyser (EPMA), respectively. The museum complex turned out to show good protection against gaseous pollutants, especially SO2 and O3. The concentrations of these pollutants were significantly reduced inside the building in comparison to the outdoor ones. Similar protective character of the museum complex was established in case of the coarse fraction of PM; however with some limitations. Single particle analysis showed that the relative abundance of carbon-rich particles inside the museum was greater than outside. Moreover, these particles contributed more to the fine fraction of PM than to the coarse fraction. Therefore, for better preservation of cultural heritage, special attention should be paid to the small particles and their distribution within the museum. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000301559100007 |
Publication Date |
2011-11-22 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0026-265x; 0026-265x |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
3.034 |
Times cited |
25 |
Open Access |
|
|
|
Notes |
; The presented work was realised in the frame of the project Preventive conservation/preservation in the museum Plantin-Moretus/Prentenkabinet, Antwerp, financed by the Flemish Government. Special thanks are due to Mrs Hanne Moris and Mrs Elke van Herck and all the staff of the Museum Plantin-Moretus/Print Room in Antwerp for their sincere interest in this work and their eager assistance during all the sampling campaigns. Barbara Krupinska is supported as PhD student by the Flemish Fund for Scientific Research (FWO, Belgium). ; |
Approved |
Most recent IF: 3.034; 2012 IF: 2.879 |
|
|
Call Number |
UA @ admin @ c:irua:94466 |
Serial |
5483 |
|
Permanent link to this record |
|
|
|
|
Author |
Hellar-Kihampa, H.; Potgieter-Vermaak, S.; De Wael, K.; Lugwisha, E.; van Espen, P.; Van Grieken, R. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Concentration profiles of metal contaminants in fluvial sediments of a rural-urban drainage basin in Tanzania |
Type |
A1 Journal article |
|
Year |
2014 |
Publication |
International journal of environmental analytical chemistry |
Abbreviated Journal |
Int J Environ An Ch |
|
|
Volume |
94 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
1 |
Pages |
77-98 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
This study investigated concentration profiles of trace, rare earth and platinum group metals in fluvial sediments from the Pangani river basin (43,650 km2), one of the largest river basins in Tanzania, to assess its environmental quality. Sediment samples were collected in two distinct seasons from 12 representative sites of diverse land-use practices and characterised by ICP-MS after optimised microwave digestion. Ecological risks were assessed by evaluation of pollution index and comparison with legislated sediment quality guidelines (SQG). The results revealed contamination by some trace metals (e.g. Pb, V, Cu, Cr, Ni, Cd, As, Co, Mn and Zn) in concentrations ranging from 0.7 to 2940 mg kg−1, and four rare earth elements (Y, Ce, Nd, Yb) in concentrations ranging from 0.9 (Yb) to 500 mg kg−1 dry weight (Ce), which significantly exceeded the estimated background values at some stations. Palladium was the only platinum group element that was detected in quantifiable concentrations (0.33.5 mg kg−1). Concentrations of some trace metals exceeded the SQGs at some localised areas. Principal component analysis and multivariate correlations indicated geochemical characteristics of the area as the major control of metal concentrations and spatial variability. Organic matter and clay contents also played a significant role in metal distributions. Assessment of land-use practices upstream of the sampling locations was used to trace potential anthropogenic sources of metal enrichments, where highest levels were found in areas close to urban centres and agricultural activities. The study provides baseline data for future monitoring programs, and highlights the need for more comprehensive analysis involving a wider spatio-temporal scale and ecotoxicological risk assessment. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000329774500007 |
Publication Date |
2013-05-24 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0306-7319 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.208 |
Times cited |
5 |
Open Access |
|
|
|
Notes |
; The participants of this research gratefully acknowledge the financial support of the Belgian Development Agency (BTC). The contribution of the Pangani Basin Water Board (PBWB), especially Ms Arafa Maggidi in provision of valuable information and assistance with the sampling campaigns is greatly appreciated. We sincerely acknowledge the assistance of Mr. Elisa Dunstan Kiwelu of Ardhi University, Dar es Salaam, Tanzania in mapping the study area; Mr Peter Machibya of the Department of Geology, University of Dar es Salaam, Tanzania in sediment characterisation; and Dr Valentine Kayawe Mubiana of the Department of Biology, University of Antwerp in ICP-MS analysis. The contributions of six anonymous reviewers, which greatly improved the manuscript for this paper, are highly appreciated. ; |
Approved |
Most recent IF: 1.208; 2014 IF: 1.295 |
|
|
Call Number |
UA @ admin @ c:irua:109234 |
Serial |
5547 |
|
Permanent link to this record |
|
|
|
|
Author |
Elia, A.; De Wael, K.; Dowsett, M.; Adriaens, A. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Electrochemical deposition of a copper carboxylate layer on copper as potential corrosion inhibitor |
Type |
A1 Journal article |
|
Year |
2011 |
Publication |
Journal of solid state electrochemistry |
Abbreviated Journal |
J Solid State Electr |
|
|
Volume |
16 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
1 |
Pages |
143-148 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Carboxylic acids and sodium carboxylates are used to protect metals against aqueous and atmospheric corrosion. In this paper, we describe the application of a layer of copper carboxylate on the surface of a copper electrode by means of cyclic voltammetry technique and tests which measure the corresponding resistance to aqueous corrosion. Unlike the soaking process, which also forms a film on the surface, the use of cyclic voltammetry allows one to follow the deposition process of the copper carboxylates onto the electrode. The modified electrodes have been characterised with infrared spectroscopy. In addition, the corrosion resistance of the film has been investigated using polarisation resistance and Tafel plot measurements. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000298651700018 |
Publication Date |
2011-01-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1432-8488 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.316 |
Times cited |
8 |
Open Access |
|
|
|
Notes |
; Authors would like to acknowledge the Research Foundation-Flanders (FWO) for funding assistance (A. Elia is a FWO aspirant) and V. Vermeersch and S. Van Vlierberghe (Ghent University, Polymer Chemistry and Biomaterials Research Group) for the FTIR-ATR measurements. ; |
Approved |
Most recent IF: 2.316; 2011 IF: 2.131 |
|
|
Call Number |
UA @ admin @ c:irua:89618 |
Serial |
5588 |
|
Permanent link to this record |
|
|
|
|
Author |
Trashin, S.; De Jong, M.; Breugelmans, T.; Pilehvar, S.; De Wael, K. |
![goto web page (via DOI) doi](http://nano.uantwerpen.be/nanorefs/img/doi.gif)
|
|
Title |
Label-free impedance aptasensor for major peanut allergen Ara h 1 |
Type |
A1 Journal article |
|
Year |
2015 |
Publication |
Electroanalysis |
Abbreviated Journal |
|
|
|
Volume |
27 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
1 |
Pages |
32-37 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Applied Electrochemistry & Catalysis (ELCAT) |
|
|
Abstract |
The peanut allergen Ara h 1 belonging to the vicilin family of seed storage proteins is known to be a suitable marker for peanut detection in foods. In the present work, we suggest an electrochemical detection of Ara h 1 using a recently selected 80-base DNA aptamer. The detection strategy relies on insulation effect of a bulky protein captured by an immobilized aptamer. The electrodes were modified by the aptamer and characterized using electrochemical impedance spectroscopy (EIS). The aptamer surface density and analytical parameters of the calibration curves for Ara h 1 were compared with the system prepared with thrombin binding aptamer (TBA) and operated in the same conditions. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000347838300004 |
Publication Date |
2014-10-13 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
10 |
Open Access |
|
|
|
Notes |
; ST greatly appreciates the Research Council University of Antwerp (IWS BOF UA) for funding the post-doctoral fellowship. ; |
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ admin @ c:irua:119442 |
Serial |
5686 |
|
Permanent link to this record |
|
|
|
|
Author |
Buczyńska, A.J.; Geypens, B.; Van Grieken, R.; De Wael, K. |
![goto web page (via DOI) doi](http://nano.uantwerpen.be/nanorefs/img/doi.gif)
|
|
Title |
Large-volume injection combined with gas chromatography/isotope ratio mass spectrometry for the analysis of polycyclic aromatic hydrocarbons |
Type |
A1 Journal article |
|
Year |
2014 |
Publication |
Rapid communications in mass spectrometry |
Abbreviated Journal |
Rapid Commun Mass Sp |
|
|
Volume |
28 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
1 |
Pages |
1-9 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
RATIONALE: Compound-specific stable isotope analyses of carbon require relatively large amounts of sample for reliable analyses. Commonly applied injections of 1 μL may thus be inefficient for samples with low concentrations of pollutants (e.g. air particulate matter) or when the amount of a sample is limited. METHODS: A Large-Volume Injection (LVI) method for carbon stable isotope ratio analysis of Polycyclic Aromatic Hydrocarbons (PAHs) was optimized in this study. Gas chromatography/combustion/isotope ratio mass spectrometry (GCCIRMS) and ion trap mass spectrometry (ITMS) were used for the determination of stable carbon isotope ratios and quantification of compounds, respectively. RESULTS: The optimized method resulted in very good reproducibility, even for the most volatile PAH, naphthalene, when a small amount of higher boiling co-solvent was used. No significant fractionation of isotope ratios could be seen and the recoveries of analytes were similar to or better than that of a splitless cold injection. CONCLUSIONS: Injection of 100 μL, instead of the commonly used 1 μL, increases the detection limit for PAHs significantly and/or simplifies the sample preparation step. Using our optimized method, stable carbon isotope ratios can be reliably measured in samples with concentrations of PAHs down to 0.050.1 ng μL1. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000328248300007 |
Publication Date |
2013-12-16 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0951-4198 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.998 |
Times cited |
5 |
Open Access |
|
|
|
Notes |
; ; |
Approved |
Most recent IF: 1.998; 2014 IF: 2.253 |
|
|
Call Number |
UA @ admin @ c:irua:111677 |
Serial |
5689 |
|
Permanent link to this record |
|
|
|
|
Author |
De Keersmaecker, M.; De Wael, K.; Adriaens, A. |
![goto web page (via DOI) doi](http://nano.uantwerpen.be/nanorefs/img/doi.gif)
|
|
Title |
The use of lead dodecanoate as an environmentally friendly coating to inhibit the corrosion of lead objects : comparison of three different deposition methods |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
Progress in organic coatings |
Abbreviated Journal |
Prog Org Coat |
|
|
Volume |
74 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
1 |
Pages |
1-7 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
An aqueous sodium dodecanoate solution has been used for the formation of a protective coating for lead. Three deposition methods have been compared: immobilization using cyclic voltammetry, immersion and amperometry. Apart from this, we tested a reduction pretreatment of the lead surface (−1.5 V during 600 s) in order to obtain a more reproducible coating, resulting in a better corrosion protection behavior. The corrosion inhibition properties were examined using potentiodynamic polarization curves and electrochemical impedance measurements in a standard corrosive environment. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000302585300001 |
Publication Date |
2012-02-16 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0300-9440; 0033-0655 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.858 |
Times cited |
8 |
Open Access |
|
|
|
Notes |
; The Research Foundation – Flanders (FWO) and Ghent University are acknowledged for funding this work. The authors would like to thank Pieter Van Hoe for the production of the embedded lead electrodes. They also acknowledge Pieter Arickx and Jonas Van Damme for their contribution. ; |
Approved |
Most recent IF: 2.858; 2012 IF: 1.848 |
|
|
Call Number |
UA @ admin @ c:irua:96354 |
Serial |
5894 |
|
Permanent link to this record |
|
|
|
|
Author |
Hellar-Kihampa, H.; De Wael, K.; Lugwisha, E.; Van Grieken, R. |
![goto web page (via DOI) doi](http://nano.uantwerpen.be/nanorefs/img/doi.gif)
|
|
Title |
Water quality assessment in Pangani river basin, Tanzania : natural and anthropogenic influences on concentrations of nutrients and inorganic ions |
Type |
A1 Journal article |
|
Year |
2013 |
Publication |
International journal of river basin management |
Abbreviated Journal |
|
|
|
Volume |
11 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
1 |
Pages |
55-75 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The ongoing rapid expansions of human activities and population dynamics have potential impact on the environmental quality of the Pangani river basin, one of the largest water resources in Tanzania, including possible loadings of different kinds of micro-contaminants. However, specific extents of the impacts are rather not well investigated. In this work, we assessed the environmental quality of the basin, based on seasonal characterisation of physicochemical water and sediments parameters, dissolved inorganic ions and nutrient loads. The contributions of geochemical processes and land-use practices were evaluated by multivariate correlations and principal component analysis (PCA). Hierarchical cluster analysis was used to classify similar water quality stations and identify the most and least enriched ones. Surface waters were slightly alkaline, characterised by low total dissolved solids (48652 mg/L). Extremely low oxygen concentration (2.0 mg/L) was also a cause of concern at one station. The Na+ and HCO3 − ions provided the dominant cation and anion, respectively. PCA identified weathering of carbonate and Na+ bearing rocks, gypsum dissolution and atmospheric deposition of sea-salt as the major factors controlling the ionic composition, contributing more than 60% of the spatial variance. Concentration profiles of the chemical species showed a generally low level of anthropogenic inputs, except at a few locations where nitrate and nitrite were significantly enriched above the limits of safe exposure, with patterns indicating influences of farming and livestock keeping. A seasonal difference was observed, with lower ion concentrations during the rainy season, likely due to the dilution effect of increased water discharge. The study provides new insights into the environmental quality of the basin, and indicates the need for continuous monitoring and assessment of the chemical species in the area. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2013-01-07 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1571-5124 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ admin @ c:irua:104621 |
Serial |
5909 |
|
Permanent link to this record |
|
|
|
|
Author |
Storme, P.; Fransen, E.; De Wael, K.; Caen, J. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
X-Ray Fluorescence as an analytical tool for studying the copper matrices in the collection of the Museum Plantin-Moretus |
Type |
A1 Journal article |
|
Year |
2017 |
Publication |
De gulden passer |
Abbreviated Journal |
|
|
|
Volume |
95 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
1 |
Pages |
7-33 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; History; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0777-5067 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ admin @ c:irua:144111 |
Serial |
5913 |
|
Permanent link to this record |
|
|
|
|
Author |
Morales-Yánez, F.; Trashin, S.; Sariego, I.; Roucher, C.; Paredis, L.; Chico, M.; De Wael, K.; Muyldermans, S.; Cooper, P.; Polman, K. |
![goto web page (via DOI) doi](http://nano.uantwerpen.be/nanorefs/img/doi.gif)
|
|
Title |
Electrochemical detection of Toxocara canis excretory-secretory antigens in children from rural communities in Esmeraldas Province, Ecuador : association between active infection and high eosinophilia |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Parasites & Vectors |
Abbreviated Journal |
Parasite Vector |
|
|
Volume |
13 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
1 |
Pages |
245-247 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Background The diagnosis of active Toxocara canis infections in humans is challenging. Larval stages of T. canis do not replicate in human tissues and disease may result from infection with a single T. canis larva. Recently, we developed a nanobody-based electrochemical magnetosensor assay with superior sensitivity to detect T. canis excretory-secretory (TES) antigens. Here, we evaluate the performance of the assay in children from an Ecuadorian birth cohort that followed children to five years of age. Methods Samples were selected based on the presence of peripheral blood eosinophilia and relative eosinophil counts. The samples were analyzed by the nanobody-based electrochemical magnetosensor assay, which utilizes a bivalent biotinylated nanobody as capturing agent on the surface of streptavidin pre-coated paramagnetic beads. Detection was performed by a different nanobody chemically labelled with horseradish peroxidase. Results Of 87 samples tested, 33 (38%) scored positive for TES antigen recognition by the electrochemical magnetosensor assay. The average concentration of TES antigen in serum was 2.1 ng/ml (SD = 1.1). The positive result in the electrochemical assay was associated with eosinophilia > 19% (P = 0.001). Parasitological data were available for 57 samples. There was no significant association between positivity by the electrochemical assay and the presence of other soil-transmitted helminth infections. Conclusions Our nanobody-based electrochemical assay provides highly sensitive quantification of TES antigens in serum and has potential as a valuable tool for the diagnosis of active human toxocariasis. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000535618800003 |
Publication Date |
2020-05-12 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1756-3305 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
3.2 |
Times cited |
|
Open Access |
|
|
|
Notes |
; This project was funded by the Fonds Wetenschappelijk Onderzoek-Vlaanderen (FWO-Flanders), project No. G.0189.13N. The ECUAVIDA cohort was funded by the Wellcome Trust (grant 072405/Z/03/Z and 088862/Z/09/Z). ; |
Approved |
Most recent IF: 3.2; 2020 IF: 3.08 |
|
|
Call Number |
UA @ admin @ c:irua:168966 |
Serial |
6501 |
|
Permanent link to this record |
|
|
|
|
Author |
Balashova, I.O.; Tolbin, A.Y.; Tarakanov, P.A.; Krot, A.R.; Fedorova, K., V; Sergeeva, I.A.; Trashin, S.A.; De Wael, K.; Pushkarev, V.E.; Koifman, M.O.; Ponomarev, G., V. |
![goto web page (via DOI) doi](http://nano.uantwerpen.be/nanorefs/img/doi.gif)
|
|
Title |
A covalently linked dyad based on zinc phthalocyanine and methylpheophorbide α : synthetic and physicochemical study |
Type |
A1 Journal article |
|
Year |
2021 |
Publication |
Macroheterocycles |
Abbreviated Journal |
|
|
|
Volume |
14 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
1 |
Pages |
40-50 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The first covalently linked conjugate of metal phthalocyaninate and chlorin e(6) derivative has been obtained by transesterification of alpha-ketomethyl ester in methylpheophorbide a with zinc(II) 2-(2-hydroxymethylbenzyloxy)-9(10),16(17),23(24)-tri-tert-butylphthalocyaninate under mild conditions. The dyad exhibits a panchromatic nature revealing both the phthalocyanine and pheophorbide derived bands in the UV-Vis absorption spectrum. The H-1 NMR spectroscopy data combined with theoretical calculations indicate the presence of spatial intramolecular interactions between the phthalocyanine, pheophorbide and spacer fragments of the dyad allowing to forecast its enhanced nonlinear optical properties, as well as the characteristic energy transfer from the excited pheophorbide subunit to the phthalocyanine core. Indeed, when excited in the UV-Vis range, the conjugate shows red fluorescence with the spectral maximum at 686 nm, which is close to the one of the initial zinc phthalocyaninate. Furthermore, the dyad effectively generates singlet oxygen and, in the presence of polyvinylpyrrolidone (PVP) as biocompatible solubilizer, forms stable micellar saline solutions with the particles ranged in size between 40 and 100 nm. These nanoparticles represent promising third-generation photosensitizing systems for application in theranostics. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000659682000003 |
Publication Date |
2021-06-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Additional Links |
UA library record; WoS full record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
|
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ admin @ c:irua:179196 |
Serial |
7386 |
|
Permanent link to this record |
|
|
|
|
Author |
Slavkovic, S.; Shoara, A.A.; Churcher, Z.R.; Daems, E.; De Wael, K.; Sobott, F.; Johnson, P.E. |
![goto web page (via DOI) doi](http://nano.uantwerpen.be/nanorefs/img/doi.gif)
|
|
Title |
DNA binding by the antimalarial compound artemisinin |
Type |
A1 Journal article |
|
Year |
2022 |
Publication |
Scientific reports |
Abbreviated Journal |
|
|
|
Volume |
12 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
1 |
Pages |
133 |
|
|
Keywords |
A1 Journal article; Pharmacology. Therapy; Engineering sciences. Technology; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab) |
|
|
Abstract |
Artemisinin (ART) is a vital medicinal compound that is used alone or as part of a combination therapy against malaria. ART is thought to function by attaching to heme covalently and alkylating a range of proteins. Using a combination of biophysical methods, we demonstrate that ART is bound by three-way junction and duplex containing DNA molecules. Binding of ART by DNA is first shown for the cocaine-binding DNA aptamer and extensively studied using this DNA molecule. Isothermal titration calorimetry methods show that the binding of ART is both entropically and enthalpically driven at physiological NaCl concentration. Native mass spectrometry methods confirm DNA binding and show that a non-covalent complex is formed. Nuclear magnetic resonance spectroscopy shows that ART binds at the three-way junction of the cocaine-binding aptamer, and that binding results in the folding of the structure-switching variant of this aptamer. This structure-switching ability was exploited using the photochrome aptamer switch assay to demonstrate that ART can be detected using this biosensing assay. This study is the first to demonstrate the DNA binding ability of ART and should lay the foundation for further work to study implications of DNA binding for the antimalarial activity of ART. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000740510500120 |
Publication Date |
2022-01-07 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2045-2322 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:184507 |
Serial |
8851 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Echelpoel, R.; Schram, J.; Parrilla, M.; Daems, D.; Slosse, A.; Van Durme, F.; De Wael, K. |
![goto web page (via DOI) doi](http://nano.uantwerpen.be/nanorefs/img/doi.gif)
|
|
Title |
Electrochemical methods for on-site multidrug detection at festivals |
Type |
A1 Journal article |
|
Year |
2022 |
Publication |
Sensors & Diagnostics |
Abbreviated Journal |
|
|
|
Volume |
1 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
1 |
Pages |
793-802 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab) |
|
|
Abstract |
Two electrochemical methodologies, i.e. flowchart and dual-sensor, were developed to aid law enforcement present at festivals to obtain a rapid indication of the presence of four illicit drugs in suspicious samples encountered. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2022-06-01 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:188521 |
Serial |
8856 |
|
Permanent link to this record |
|
|
|
|
Author |
Steijlen, A.S.M.; Parrilla, M.; Van Echelpoel, R.; De Wael, K. |
![goto web page (via DOI) doi](http://nano.uantwerpen.be/nanorefs/img/doi.gif)
|
|
Title |
Dual microfluidic sensor system for enriched electrochemical profiling and identification of illicit drugs on-site |
Type |
A1 Journal article |
|
Year |
2024 |
Publication |
Analytical chemistry |
Abbreviated Journal |
|
|
|
Volume |
96 |
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
1 |
Pages |
590-598 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab) |
|
|
Abstract |
Electrochemical sensors have emerged as a new analytical tool for illicit drug detection to facilitate ultrafast and accurate identification of suspicious compounds on-site. Drugs of abuse can be identified using their unique voltammetric fingerprint at a given pH. Today, the right buffer solution is manually selected based on drug appearance, and in some cases, a consecutive analysis in two different pH solutions is required. In this work, we present a disposable microfluidic multichannel sensor system that automatically records fingerprints in two pH solutions (e.g., pH 5 and pH 12). This system has two advantages. It will overcome the manual selection of a buffer solution at the right pH, decrease analysis time, and minimize the risk of human errors. Second, the combination of two fingerprints, the superfingerprint, contains more detailed information about the samples, which enhances the selectivity of the analytical technique. First, real-time pH measurements proved that the sample can be brought to the desired pH within a minute. Subsequently, an electrochemical study on the microfluidic platform with 1 mM illicit drug standards of MDMA, cocaine, heroin, and methamphetamine showed that the characteristic voltammetric fingerprints and peak potentials are reproducible, also in the presence of common cutting agents. Finally, the microfluidic concept was validated with real confiscated samples, showing promising results for the user-friendly identification of drugs of abuse. In short, this paper presents a successful proof-of-concept study of a multichannel microfluidic sensor system to enrich the fingerprints of illicit drugs at pH 5 and pH 12, thus providing a low-cost, portable, and rapid identification system of illicit drugs with minimal user intervention. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
001139443500001 |
Publication Date |
2023-12-28 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2700; 5206-882x |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
7.4 |
Times cited |
|
Open Access |
Not_Open_Access |
|
|
Notes |
|
Approved |
Most recent IF: 7.4; 2024 IF: 6.32 |
|
|
Call Number |
UA @ admin @ c:irua:201877 |
Serial |
9024 |
|
Permanent link to this record |
|
|
|
|
Author |
de Jong, M.; Florea, A.; Daems, D.; Van Loon, J.; Samyn, N.; De Wael, K. |
![goto web page (via DOI) doi](http://nano.uantwerpen.be/nanorefs/img/doi.gif)
|
|
Title |
Electrochemical Analysis of Speedball-like Polydrug Samples |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Analyst |
Abbreviated Journal |
Analyst |
|
|
Volume |
|
Issue ![sorted by Issue field, descending order (down)](img/sort_desc.gif) |
|
Pages |
|
|
|
Keywords |
A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Product development |
|
|
Abstract |
Increasing global production, trafficking and consumption of drugs of abuse cause an emerging threat to people’s health and safety. Electrochemical approaches have proven to be useful for on-site analysis of drugs of abuse. However, few attention has been focused on the analysis of polydrug samples, despite these samples causing severe health concerns, certainly when stimulants and depressants are combined, as is the case for Speedball, a mixture of cocaine and heroin. In this work, we provide solutions for the selective detection of cocaine (stimulant) in polydrug samples adulterated with heroin and codeine (depressants). The presence of either one of these compounds in cocaine street samples leads to an overlap with the cocaine signal in square-wave voltammetry measurements at unmodified carbon screen-printed electrodes, leading to inconclusive screening results in the field. The provided solutions to this problem consist of two parallel approaches: (i) cathodic pretreatment of the carbon screen-printed electrode surface prior to measurement in both alkaline and neutral conditions; (ii) electropolymerization of orthophenylenediamine on graphene modified carbon screen-printed electrodes prior to measurement in neutral conditions. Both strategies allow simultaneous detection of cocaine and heroin in speedball samples as well as simultaneous detection of cocaine and codeine. Implementing these strategies in portable devices holds great potential for significantly improved accuracy of on-site cocaine screening in polydrug samples. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000568961600011 |
Publication Date |
2020-07-28 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2654 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
4.2 |
Times cited |
|
Open Access |
|
|
|
Notes |
This work was supported by IOF-SBO and IOF-POC from University of Antwerp, Antwerp, Belgium; and VLAIO IM [HBC.2019.2181], Brussels, Belgium. |
Approved |
Most recent IF: 4.2; 2020 IF: 3.885 |
|
|
Call Number |
AXES @ axes @c:irua:170444 |
Serial |
6395 |
|
Permanent link to this record |