|
Records |
Links |
|
Author |
van Dyck, D.; Van Aert, S.; den Dekker, A.J. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Physical limits on atomic resolution |
Type |
A1 Journal article |
|
Year |
2004 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
|
|
Volume |
10 |
Issue |
|
Pages ![sorted by First Page field, descending order (down)](img/sort_desc.gif) |
153-157 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Cambridge, Mass. |
Editor |
|
|
|
Language |
|
Wos |
000188882100022 |
Publication Date |
2004-08-11 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1431-9276;1435-8115; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.891 |
Times cited |
14 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 1.891; 2004 IF: 2.389 |
|
|
Call Number |
UA @ lucian @ c:irua:47515 |
Serial |
2616 |
|
Permanent link to this record |
|
|
|
|
Author |
Nord, M.; Verbeeck, J. |
![goto web page (via DOI) doi](http://nano.uantwerpen.be/nanorefs/img/doi.gif)
|
|
Title |
Open Source Development Tools for Robust and Reproducible Electron Microscopy Data Analysis |
Type |
P3 |
|
Year |
2019 |
Publication |
Microscopy And Microanalysis |
Abbreviated Journal |
Microsc Microanal |
|
|
Volume |
25 |
Issue |
S2 |
Pages ![sorted by First Page field, descending order (down)](img/sort_desc.gif) |
138-139 |
|
|
Keywords |
P3; Electron Microscopy for Materials Science (EMAT) ; |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2019-08-05 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
|
|
|
Impact Factor |
1.891 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 1.891 |
|
|
Call Number |
EMAT @ emat @ |
Serial |
5378 |
|
Permanent link to this record |
|
|
|
|
Author |
Jones, L.; Martinez, G.T.; Béché, A.; Van Aert, S.; Nellist, P.D. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Getting the best from an imperfect detector : an alternative normalisation procedure for quantitative HAADF STEM |
Type |
A1 Journal article |
|
Year |
2014 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
|
|
Volume |
20 |
Issue |
S3 |
Pages ![sorted by First Page field, descending order (down)](img/sort_desc.gif) |
126-127 |
|
|
Keywords |
A1 Journal article; Engineering Management (ENM); Electron microscopy for materials research (EMAT) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Cambridge, Mass. |
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2014-08-27 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
1.891 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 1.891; 2014 IF: 1.877 |
|
|
Call Number |
UA @ lucian @ c:irua:136445 |
Serial |
4500 |
|
Permanent link to this record |
|
|
|
|
Author |
Bals, S.; Tirry, W.; Geurts, R.; Yang, Z.; Schryvers, D. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
High-quality sample preparation by low kV FIB thinning for analytical TEM measurements |
Type |
A1 Journal article |
|
Year |
2007 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
|
|
Volume |
13 |
Issue |
2 |
Pages ![sorted by First Page field, descending order (down)](img/sort_desc.gif) |
80-86 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
Focused ion beam specimen preparation has been used for NiTi samples and SrTiO(3)/SrRuO(3) multilayers with prevention of surface amorphization and Ga implantation by a 2-kV cleaning procedure. Transmission electron microscopy techniques show that the samples are of high quality with a controlled thickness over large scales. Furthermore, preferential thinning effects in multicompounds are avoided, which is important when analytical transmission electron microscopy measurements need to be interpreted in a quantitative manner. The results are compared to similar measurements acquired for samples obtained using conventional preparation techniques such as electropolishing for alloys and ion milling for oxides. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Cambridge, Mass. |
Editor |
|
|
|
Language |
|
Wos |
000245662200002 |
Publication Date |
2007-03-19 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1431-9276;1435-8115; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.891 |
Times cited |
82 |
Open Access |
|
|
|
Notes |
Fwo; Goa |
Approved |
Most recent IF: 1.891; 2007 IF: 1.941 |
|
|
Call Number |
UA @ lucian @ c:irua:65850 |
Serial |
1441 |
|
Permanent link to this record |
|
|
|
|
Author |
Tian, H.; Schryvers, D.; Shabalovskaya, S.; van Humbeeck, J. |
![goto web page (via DOI) doi](http://nano.uantwerpen.be/nanorefs/img/doi.gif)
|
|
Title |
Microstructure of surface and subsurface layers of a Ni-Ti shape memory microwire |
Type |
A1 Journal article |
|
Year |
2009 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
|
|
Volume |
15 |
Issue |
|
Pages ![sorted by First Page field, descending order (down)](img/sort_desc.gif) |
62-70 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
The microstructure of a 55 Êm diameter, cold-worked Ni-Ti microwire is investigated by different transmission electron microscopy techniques. The surface consists of a few hundred nanometer thick oxide layer composed of TiO and TiO2 with a small fraction of inhomogeneously distributed Ni. The interior of the wire has a core-shell structure with primarily B2 grains in the 1 Êm thick shell, and heavily twinned B19 martensite in the core. This core-shell structure can be explained by a concentration gradient of the alloying elements resulting in a structure separation due to the strong temperature dependence of the martensitic start temperature. Moreover, in between the B2 part of the metallic core-shell and the oxide layer, a Ni3Ti interfacial layer is detected. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Cambridge, Mass. |
Editor |
|
|
|
Language |
|
Wos |
000262912700009 |
Publication Date |
2009-01-15 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1431-9276;1435-8115; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.891 |
Times cited |
15 |
Open Access |
|
|
|
Notes |
FWO G.0465.05; Multimat |
Approved |
Most recent IF: 1.891; 2009 IF: 3.035 |
|
|
Call Number |
UA @ lucian @ c:irua:72319 |
Serial |
2074 |
|
Permanent link to this record |
|
|
|
|
Author |
Lu, J.; Roeffaers, M.B.J.; Bartholomeeusen, E.; Sels, B.F.; Schryvers, D. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Intergrowth of components and ramps in coffin-shaped ZSM-5 zeolite crystals unraveled by focused ion beam-assisted transmission electron microscopy |
Type |
A1 Journal article |
|
Year |
2014 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
|
|
Volume |
20 |
Issue |
1 |
Pages ![sorted by First Page field, descending order (down)](img/sort_desc.gif) |
42-49 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
Scanning electron microscopy, focused ion beam (FIB), and transmission electron microscopy are combined to study the intergrowth of 90 degrees rotational components and of ramps in coffin-shaped ZSM-5 crystals. The 90 degrees rotational boundaries with local zig-zag features between different intergrowth components are observed in the main part of crystal. Also a new kind of displacement boundary is described. At the displacement boundary there is a shift of the unit cells along the boundary without a change in orientation. Based on lamellae prepared with FIB from different positions of the ramps and crystal, the orientation relationships between ramps and the main part of the crystal are studied and the three-dimensional morphology and growth mechanism of the ramp are illustrated. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Cambridge, Mass. |
Editor |
|
|
|
Language |
|
Wos |
000335378400006 |
Publication Date |
2013-11-05 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1431-9276;1435-8115; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.891 |
Times cited |
7 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 1.891; 2014 IF: 1.877 |
|
|
Call Number |
UA @ lucian @ c:irua:117688 |
Serial |
1697 |
|
Permanent link to this record |
|
|
|
|
Author |
MacArthur, K.E.; Yankovich, A.B.; Béché, A.; Luysberg, M.; Brown, H.G.; Findlay, S.D.; Heggen, M.; Allen, L.J. |
![goto web page url](http://nano.uantwerpen.be/nanorefs/img/www.gif)
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Optimizing Experimental Conditions for Accurate Quantitative Energy-Dispersive X-ray Analysis of Interfaces at the Atomic Scale |
Type |
A1 Journal article |
|
Year |
2021 |
Publication |
Microscopy And Microanalysis |
Abbreviated Journal |
Microsc Microanal |
|
|
Volume |
|
Issue |
|
Pages ![sorted by First Page field, descending order (down)](img/sort_desc.gif) |
1-15 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
The invention of silicon drift detectors has resulted in an unprecedented improvement in detection efficiency for energy-dispersive X-ray (EDX) spectroscopy in the scanning transmission electron microscope. The result is numerous beautiful atomic-scale maps, which provide insights into the internal structure of a variety of materials. However, the task still remains to understand exactly where the X-ray signal comes from and how accurately it can be quantified. Unfortunately, when crystals are aligned with a low-order zone axis parallel to the incident beam direction, as is necessary for atomic-resolution imaging, the electron beam channels. When the beam becomes localized in this way, the relationship between the concentration of a particular element and its spectroscopic X-ray signal is generally nonlinear. Here, we discuss the combined effect of both spatial integration and sample tilt for ameliorating the effects of channeling and improving the accuracy of EDX quantification. Both simulations and experimental results will be presented for a perovskite-based oxide interface. We examine how the scattering and spreading of the electron beam can lead to erroneous interpretation of interface compositions, and what approaches can be made to improve our understanding of the underlying atomic structure. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000664532400007 |
Publication Date |
2021-04-12 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.891 |
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
The authors would like to thank Jürgen Schubert for helping to supply the sample and valuable discussions on the topic. K. E. MacArthur and M. Heggen acknowledge the Helmholtz Funding agency and the DFG (grant number HE 7192/1-2) for their financial support of this work. L. J. Allen acknowledges the support of the Alexander von Humboldt Foundation. This research was supported under the Discovery Projects funding scheme of the Australian Research Council (Projects DP140102538 and FT190100619). K.E. MacArthur, A.B. Yankovich and A. Béché acknowledge support from the European Union’s Horizon 2020 research innovation program under grant agreement No. 823717 – ESTEEM3. A.B. Yankovich also acknowledges support from the Materials Science Area of Advance at Chalmers and the Swedish Research Council (VR, under grant No: 2020-04986).; esteem3TA; esteem3reported |
Approved |
Most recent IF: 1.891 |
|
|
Call Number |
EMAT @ emat @c:irua:178129 |
Serial |
6760 |
|
Permanent link to this record |
|
|
|
|
Author |
Ning, S.; Xu, W.; Ma, Y.; Loh, L.; Pennycook, T.J.; Zhou, W.; Zhang, F.; Bosman, M.; Pennycook, S.J.; He, Q.; Loh, N.D. |
![goto web page url](http://nano.uantwerpen.be/nanorefs/img/www.gif)
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Accurate and Robust Calibration of the Uniform Affine Transformation Between Scan-Camera Coordinates for Atom-Resolved In-Focus 4D-STEM Datasets |
Type |
A1 Journal article |
|
Year |
2022 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
|
|
Volume |
|
Issue |
|
Pages ![sorted by First Page field, descending order (down)](img/sort_desc.gif) |
1-11 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
Accurate geometrical calibration between the scan coordinates and the camera coordinates is critical in four-dimensional scanning transmission electron microscopy (4D-STEM) for both quantitative imaging and ptychographic reconstructions. For atomic-resolved, in-focus 4D-STEM datasets, we propose a hybrid method incorporating two sub-routines, namely a J-matrix method and a Fourier method, which can calibrate the uniform affine transformation between the scan-camera coordinates using raw data, without a priori knowledge about the crystal structure of the specimen. The hybrid method is found robust against scan distortions and residual probe aberrations. It is also effective even when defects are present in the specimen, or the specimen becomes relatively thick. We will demonstrate that a successful geometrical calibration with the hybrid method will lead to a more reliable recovery of both the specimen and the electron probe in a ptychographic reconstruction. We will also show that, although the elimination of local scan position errors still requires an iterative approach, the rate of convergence can be improved, and the residual errors can be further reduced if the hybrid method can be firstly applied for initial calibration. The code is made available as a simple-to-use tool to correct affine transformations of the scan-camera coordinates in 4D-STEM experiments. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000767045700001 |
Publication Date |
2022-03-09 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.8 |
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
N. D. Loh kindly acknowledges support from NUS Early Career Research Award (R-154-000-B35-133), MOE’s AcRF Tier 1 grant nr. R-284-000-172-114 and NRF CRP grant number NRF-CRP16-2015-05. Q. He would also like to acknowledge the support of the National Research Foundation (NRF) Singapore, under its NRF Fellowship (NRF-NRFF11-2019-0002). W. Zhou acknowledges the support from Beijing Outstanding Young Scientist Program (BJJWZYJH01201914430039). F. Zhang acknowledges the support of the National Natural Science Foundation of China (11775105, 12074167). T. J. Pennycook acknowledges funding under the European Union’s Horizon 2020 research and innovation programme from the European Research Council (ERC) Grant agreement No. 802123-HDEM. |
Approved |
Most recent IF: 2.8 |
|
|
Call Number |
EMAT @ emat @c:irua:186958 |
Serial |
6957 |
|
Permanent link to this record |
|
|
|
|
Author |
Yu, C.-P.; Friedrich, T.; Jannis, D.; Van Aert, S.; Verbeeck, J. |
![goto web page url](http://nano.uantwerpen.be/nanorefs/img/www.gif)
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Real-Time Integration Center of Mass (riCOM) Reconstruction for 4D STEM |
Type |
A1 Journal article |
|
Year |
2022 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
|
|
Volume |
|
Issue |
|
Pages ![sorted by First Page field, descending order (down)](img/sort_desc.gif) |
1-12 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
A real-time image reconstruction method for scanning transmission electron microscopy (STEM) is proposed. With an algorithm requiring only the center of mass of the diffraction pattern at one probe position at a time, it is able to update the resulting image each time a new probe position is visited without storing any intermediate diffraction patterns. The results show clear features at high spatial frequency, such as atomic column positions. It is also demonstrated that some common post-processing methods, such as band-pass filtering, can be directly integrated in the real-time processing flow. Compared with other reconstruction methods, the proposed method produces high-quality reconstructions with good noise robustness at extremely low memory and computational requirements. An efficient, interactive open source implementation of the concept is further presented, which is compatible with frame-based, as well as event-based camera/file types. This method provides the attractive feature of immediate feedback that microscope operators have become used to, for example, conventional high-angle annular dark field STEM imaging, allowing for rapid decision-making and fine-tuning to obtain the best possible images for beam-sensitive samples at the lowest possible dose. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000792176100001 |
Publication Date |
2022-04-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.8 |
Times cited |
7 |
Open Access |
OpenAccess |
|
|
Notes |
Bijzonder Onderzoeksfonds UGent; H2020 European Research Council, 770887 ; H2020 European Research Council, 823717 ; H2020 European Research Council, ESTEEM3 / 823717 ; H2020 European Research Council, PICOMETRICS / 770887 ; Fonds Wetenschappelijk Onderzoek, 30489208 ; Herculesstichting; esteem3reported; esteem3jra |
Approved |
Most recent IF: 2.8 |
|
|
Call Number |
EMAT @ emat @c:irua:188538 |
Serial |
7068 |
|
Permanent link to this record |
|
|
|
|
Author |
De wael, A.; De Backer, A.; Yu, C.-P.; Sentürk, D.G.; Lobato, I.; Faes, C.; Van Aert, S. |
![goto web page url](http://nano.uantwerpen.be/nanorefs/img/www.gif)
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Three Approaches for Representing the Statistical Uncertainty on Atom-Counting Results in Quantitative ADF STEM |
Type |
A1 Journal article |
|
Year |
2022 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
|
|
Volume |
|
Issue |
|
Pages ![sorted by First Page field, descending order (down)](img/sort_desc.gif) |
1-9 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
A decade ago, a statistics-based method was introduced to count the number of atoms from annular dark-field scanning transmission electron microscopy (ADF STEM) images. In the past years, this method was successfully applied to nanocrystals of arbitrary shape, size, and composition (and its high accuracy and precision has been demonstrated). However, the counting results obtained from this statistical framework are so far presented without a visualization of the actual uncertainty about this estimate. In this paper, we present three approaches that can be used to represent counting results together with their statistical error, and discuss which approach is most suited for further use based on simulations and an experimental ADF STEM image. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000854930500001 |
Publication Date |
2022-09-19 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
UA library record; WoS full record |
|
|
Impact Factor |
2.8 |
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
This project has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (Grant Agreement No. 770887 and No. 823717 ESTEEM3). The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through grants to A.D.w. and A.D.B. and projects G.0502.18N, G.0267.18N, and EOS 30489208. S.V.A. acknowledges TOP BOF funding from the University of Antwerp. The authors are grateful to L.M. Liz-Marzán (CIC biomaGUNE and Ikerbasque) for providing the samples. esteem3reported; esteem3jra |
Approved |
Most recent IF: 2.8 |
|
|
Call Number |
EMAT @ emat @c:irua:190585 |
Serial |
7119 |
|
Permanent link to this record |