|
Records |
Links |
|
Author |
Barich, H.; Cánovas, R.; De Wael, K. |
|
|
Title |
Electrochemical identification of hazardous phenols and their complex mixtures in real samples using unmodified screen-printed electrodes |
Type |
A1 Journal article |
|
Year |
2022 |
Publication |
Journal of electroanalytical chemistry : an international journal devoted to all aspects of electrode kynetics, interfacial structure, properties of electrolytes, colloid and biological electrochemistry. |
Abbreviated Journal |
J Electroanal Chem |
|
|
Volume |
904 |
Issue |
|
Pages |
115878 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab) |
|
|
Abstract |
The electrochemical behavior of some of the most relevant endocrine-disrupting phenols using unmodified carbon screen-printed electrodes (SPEs) is described for the first time. Experiments were made to assess the electrochemical behavior of phenol (PHOH), pentachlorophenol (PCP), 4-tert octylphenol (OP) and bisphenol A (BPA) and their determination in the most favorable conditions, using voltammetric methods such as cyclic voltammetry (CV), linear sweep voltammetry (LSV) and square wave voltammetry (SWV) in Britton Robinson (BR) buffer. Further, the usefulness of the electrochemical approach was validated with real samples from a local river and was compared to commercial phenols test kit, which is commonly used for on-site screening in industrial streams and wastewaters. Finally, the approach was compared with a lab-bench standard method using real samples, i.e., high-performance liquid chromatography with a photodiode array detector (HPLC-DAD). |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000741151200005 |
Publication Date |
2021-11-14 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1572-6657; 1873-2569 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
4.5 |
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
|
Approved |
Most recent IF: 4.5 |
|
|
Call Number |
UA @ admin @ c:irua:184384 |
Serial |
7150 |
|
Permanent link to this record |
|
|
|
|
Author |
Cánovas, R.; Blondeau, P.; Andrade, F.J. |
|
|
Title |
Modulating the mixed potential for developing biosensors: Direct potentiometric determination of glucose in whole, undiluted blood |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Biosensors & Bioelectronics |
Abbreviated Journal |
Biosens Bioelectron |
|
|
Volume |
163 |
Issue |
|
Pages |
112302-112306 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The growing demand for tools to generate chemical information in decentralized settings is creating a vast range of opportunities for potentiometric sensors, since their combination of robustness, simplicity of operation and cost can hardly be rivalled by any other technique. In previous works, we have shown that the mixed potential of a Pt electrode can be controlled with analytical purposes using a coating of Nafion, thus providing a way to develop a potentiometric biosensor for glucose. Unfortunately, the linear range of this device did not match the relevant clinical range for glucose in blood. This work presents a novel strategy to control the mixed potential that allows the development of a potentiometric biosensor for the direct detection of glucose in whole, undiluted blood without any sample pretreatment. By changing the ionomer, the analytical response can be tuned, shifting the linear range while keeping the sensitivity. Aquivion, a polyelectrolyte from the same family as Nafion, is used to stabilize the mixed potential of a platinized paper-based electrode, to entrap the enzyme and to reduce the interference from negatively charged species. Factors affecting the generation of the signal and the principle of detection are discussed. Optimization of the biosensor composition was achieved with particular focus on the characterization of the linear range and sensitivity. The accurate measurement of blood sugar levels in a single drop of whole blood with excellent recovery is presented. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2020-05-18 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0956-5663 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
12.6 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 12.6; 2020 IF: 7.78 |
|
|
Call Number |
UA @ admin @ c:irua:184382 |
Serial |
8271 |
|
Permanent link to this record |
|
|
|
|
Author |
Baez, J.F.; Compton, M.; Chahrati, S.; Cánovas, R.; Blondeau, P.; Andrade, F.J. |
|
|
Title |
Controlling the mixed potential of polyelectrolyte-coated platinum electrodes for the potentiometric detection of hydrogen peroxide |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Analytica Chimica Acta |
Abbreviated Journal |
Anal Chim Acta |
|
|
Volume |
1097 |
Issue |
|
Pages |
204-213 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The use of a Pt electrode coated with a layer of Nafion has been described in previous works as an attractive way to perform the potentiometric detection of hydrogen peroxide. Despite of the attractive features of this approach, the nature of the non-Nernstian response of this system was not properly addressed. In this work, using a mixed potential model, the open circuit potential of the Pt electrode is shown to be under kinetic control of the oxygen reduction reaction (ORR). It is proposed that hydrogen peroxide acts as an oxygenated species that blocks free sites on the Pt surface, interfering with the ORR. Therefore, the effect of the polyelectrolyte coating can be understood in terms of the modulation of the factors that affects the kinetics of the ORR, such as an increase of the H+ concentration, minimization of the effect of the spectator species, etc. Because of the complexity and the lack of models that accurately describe systems with practical applications, this work is not intended to provide a mechanistic but rather a phenomenological view on problem. A general framework to understand the factors that affect the potentiometric response is provided. Experimental evidence showing that the use of polyelectrolyte coatings are a powerful way to control the mixed potential open new ways for the development of robust and simple potentiometric sensors. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2019-11-13 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670; 1873-4324 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
6.2 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 6.2; 2020 IF: 4.95 |
|
|
Call Number |
UA @ admin @ c:irua:184381 |
Serial |
7731 |
|
Permanent link to this record |
|
|
|
|
Author |
Liu, Y.; Cánovas, R.; Crespo, G.A.; Cuartero, M. |
|
|
Title |
Thin-layer potentiometry for creatinine detection in undiluted human urine using ion-exchange membranes as barriers for charged interferences |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Analytical Chemistry |
Abbreviated Journal |
Anal Chem |
|
|
Volume |
92 |
Issue |
4 |
Pages |
3315-3323 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Herein, thin-layer potentiometry combined with ion-exchange membranes as barriers for charged interferences is demonstrated for the analytical detection of creatinine (CRE) in undiluted human urine. Briefly, CRE diffuses through an anion-exchange membrane (AEM) from a sample contained in one fluidic compartment to a second reservoir, containing the enzyme CRE deiminase. There, CRE reacts with the enzyme, and the formation of ammonium is dynamically monitored by potentiometric ammonium-selective electrodes. This analytical concept is integrated into a lab-on-a-chip microfluidic cell that allows for a high sample throughput and the operation under stop-flow mode, which allows CRE to passively diffuse across the AEM. Conveniently, positively charged species (i.e., potassium, sodium, and ammonium, among others) are repelled by the AEM and never reach the ammonium-selective electrodes; thus, possible interference in the response can be avoided. As a result, the dynamic potential response of the electrodes is entirely ascribed to the stoichiometric formation of ammonium. The new CRE biosensor exhibits a Nernstian slope, within a linear range of response from 1 to 50 mM CRE concentration. As expected, the response time (15–60 min) primarily depends on the CRE diffusion across the AEM. CRE analysis in urine samples displayed excellent results, without requiring sample pretreatment (before the introduction of the sample in the microfluidic chip) and with high compatibility with development into a potential point-of-care clinical tool. In an attempt to decrease the analysis time, the presented analytical methodology for CRE detection is translated into an all-solid-state platform, in which the enzyme is immobilized on the surface of the ammonium-selective electrode and with the AEM on top. While more work is necessary in this direction, the CRE sensor appears to be promising for CRE analysis in both urine and blood. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2020-01-23 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2700; 5206-882x |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
7.4 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 7.4; 2020 IF: 6.32 |
|
|
Call Number |
UA @ admin @ c:irua:184380 |
Serial |
8667 |
|
Permanent link to this record |
|
|
|
|
Author |
Ciftci, S.; Cánovas, R.; Neumann, F.; Paulraj, T.; Nilsson, M.; Crespo, G.A.; Madaboosi, N. |
|
|
Title |
The sweet detection of rolling circle amplification : glucose-based electrochemical genosensor for the detection of viral nucleic acid |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Biosensors & Bioelectronics |
Abbreviated Journal |
Biosens Bioelectron |
|
|
Volume |
151 |
Issue |
|
Pages |
112002-112008 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Herein, an isothermal padlock probe-based assay for the simple and portable detection of pathogens coupled with a glucose oxidase (GOx)-based electrochemical readout is reported. Infectious diseases remain a constant threat on a global scale, as in recurring pandemics. Rapid and portable diagnostics hold the promise to tackle the spreading of diseases and decentralising healthcare to point-of-care needs. Ebola, a hypervariable RNA virus causing fatalities of up to 90% for recent outbreaks in Africa, demands immediate attention for bedside diagnostics. The design of the demonstrated assay consists of a rolling circle amplification (RCA) technique, responsible for the generation of nucleic acid amplicons as RCA products (RCPs). The RCPs are generated on magnetic beads (MB) and subsequently, connected via streptavidin-biotin bonds to GOx. The enzymatic catalysis of glucose by the bound GOx allows for an indirect electrochemical measurement of the DNA target. The RCPs generated on the surface of the MB were confirmed by scanning electron microscopy, and among other experimental conditions such as the type of buffer, temperature, concentration of GOx, sampling and measurement time were evaluated for the optimum electrochemical detection. Accordingly, 125 μg mL−1 of GOx with 5 mM glucose using phosphate buffer saline (PBS), monitored for 1 min were selected as the ideal conditions. Finally, we assessed the analytical performance of the biosensing strategy by using clinical samples of Ebola virus from patients. Overall, this work provides a proof-of-concept bioassay for simple and portable molecular diagnostics of emerging pathogens using electrochemical detection, especially in resource-limited settings. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2019-12-30 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0956-5663 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
12.6 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 12.6; 2020 IF: 7.78 |
|
|
Call Number |
UA @ admin @ c:irua:184379 |
Serial |
8630 |
|
Permanent link to this record |
|
|
|
|
Author |
Thiruvottriyur Shanmugam, S.; Van Echelpoel, R.; Boeye, G.; Eliaerts, J.; Samanipour, M.; Ching, H.Y.V.; Florea, A.; Van Doorslaer, S.; Van Durme, F.; Samyn, N.; Parrilla, M.; De Wael, K. |
|
|
Title |
Towards developing a screening strategy for ecstasy : revealing the electrochemical profile |
Type |
A1 Journal article |
|
Year |
2021 |
Publication |
Chemelectrochem |
Abbreviated Journal |
Chemelectrochem |
|
|
Volume |
8 |
Issue |
24 |
Pages |
4826-4834 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Organic synthesis (ORSY); Applied Electrochemistry & Catalysis (ELCAT); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab) |
|
|
Abstract |
This article describes the development of an electrochemical screening strategy for 3,4-methylenedioxymethamphetamine (MDMA), the regular psychoactive compound in ecstasy (XTC) pills. We have investigated the specific electrochemical profile of MDMA and its electro-oxidation mechanisms at disposable graphite screen-printed electrodes. We have proved that the formation of a radical cation and subsequent reactions are indeed responsible for the electrode surface passivation, as evidenced by using electron paramagnetic resonance spectroscopy and electrochemistry. Thereafter, pure cutting agents and MDMA as well as simulated binary mixtures of compounds with MDMA were subjected to square wave voltammetry at pH 7 to understand the characteristic electrochemical profile. An additional measurement at pH 12 was able to resolve false positives and negatives occurring at pH 7. Finally, validation of the screening strategy was done by measuring a set of ecstasy street samples. Overall, our proposed electrochemical screening strategy has been demonstrated for the rapid, sensitive, and selective detection of MDMA, resolving most of the false positives and negatives given by the traditional Marquis color tests, thus exhibiting remarkable promises for the on-site screening of MDMA. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000735883700020 |
Publication Date |
2021-12-22 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2196-0216 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
4.136 |
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
|
Approved |
Most recent IF: 4.136 |
|
|
Call Number |
UA @ admin @ c:irua:184371 |
Serial |
8680 |
|
Permanent link to this record |
|
|
|
|
Author |
Ortiz-Aguayo, D.; De Wael, K.; del Valle, M. |
|
|
Title |
Voltammetric sensing using an array of modified SPCE coupled with machine learning strategies for the improved identification of opioids in presence of cutting agents |
Type |
A1 Journal article |
|
Year |
2021 |
Publication |
Journal Of Electroanalytical Chemistry |
Abbreviated Journal |
J Electroanal Chem |
|
|
Volume |
902 |
Issue |
|
Pages |
115770 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab) |
|
|
Abstract |
This work reports the use of modified screen-printed carbon electrodes (SPCEs) for the identification of three drugs of abuse and two habitual cutting agents, caffeine and paracetamol, combining voltammetric sensing and chemometrics. In order to achieve this goal, codeine, heroin and morphine were subjected to Square Wave Voltammetry (SWV) at pH 7, in order to elucidate their electrochemical fingerprints. The optimized SPCEs electrode array, which have a differentiated response for the three oxidizable compounds, was derived from Carbon, Prussian blue, Cobalt (II) phthalocyanine, Copper (II) oxide, Polypyrrole and Palladium nanoparticles ink-modified carbon electrodes. Finally, Principal Component Analysis (PCA) coupled with Silhouette parameter assessment was used to select the most suitable combination of sensors for identification of drugs of abuse in presence of cutting agents. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000714415500006 |
Publication Date |
2021-10-13 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1572-6657; 1873-2569 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
3.012 |
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
|
Approved |
Most recent IF: 3.012 |
|
|
Call Number |
UA @ admin @ c:irua:184018 |
Serial |
8745 |
|
Permanent link to this record |
|
|
|
|
Author |
Baij, L.; Liu, C.; Buijs, J.; Alvarez Martin, A.; Westert, D.; Raven, L.; Geels, N.; Noble, P.; Sprakel, J.; Keune, K. |
|
|
Title |
Understanding and optimizing Evolon® CR for varnish removal from oil paintings |
Type |
A1 Journal article |
|
Year |
2021 |
Publication |
Heritage science |
Abbreviated Journal |
|
|
|
Volume |
9 |
Issue |
1 |
Pages |
155-17 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp X-ray Imaging and Spectroscopy (AXIS) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2021-11-27 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2050-7445 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
Not_Open_Access |
|
|
Notes |
|
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ admin @ c:irua:183747 |
Serial |
8707 |
|
Permanent link to this record |
|
|
|
|
Author |
Alemam, E. |
|
|
Title |
Cleaning of wall paintings by Polyvinyl alcohol–Borax/Agarose (PVA–B/AG) double network hydrogels : characterization, assessment, and applications |
Type |
Doctoral thesis |
|
Year |
2021 |
Publication |
|
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
184 p. |
|
|
Keywords |
Doctoral thesis; Engineering sciences. Technology; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES); Antwerp X-ray Imaging and Spectroscopy (AXIS) |
|
|
Abstract |
Wall paintings make up an important section of cultural heritage. They resemble time portals that can be used to travel back into the past and witness the life of our ancestors. In these paintings, the ancient artists depicted the different aspects of their life, such as cooking, baking, farming, manufacturing, as well as thoughts and beliefs. Unfortunately, wall paintings are susceptible to degradation over time in the form of the accumulations of dirt and deposits on the painted surfaces and loss of adhesion of the paint layers at the surface. Therefore, the removal of these deposits is one of the primary duties of conservator-restorers. Such operations are intended to restore the painted surface to a condition close enough to its original state. Since cleaning artworks may cause undesirable physicochemical alterations and is nonreversible, the proper cleaning procedure should be adopted. In this regard, numerous gels have been developed and exploited for the cleaning of various artwork surfaces. Lately, polyvinyl alcohol-borax (PVA-B) and agarose (AG) hydrogels have been widely employed as cleaning materials by conservator-restorers. However, both hydrogels have shown limitations in specific cleaning practices. In this work, we investigated a new double network hydrogel based on blending PVA-B and agarose to avoid the limitations posed by the constituting hydrogels. For this reason, a detailed characterization of the PVA–B/AG double network hydrogel was performed, including chemical structure, liquid phase retention, mechanical strength, rheological behavior, and self-healing behavior of various PVA-B/AG hydrogels. These new hydrogels revealed better properties than PVA-B and agarose hydrogels and obviated their limitations. A laboratory experiment on the removal of deteriorated Paraloid® B72 proved that the PVA-B/AG hydrogel loaded 10%/10% MEK/1-PeOH was able to remove these layers efficiently. Therefore, the hydrogel was tested on a wall painting from the Temple of Seti I in Abydos – Egypt. It removed the glossy/darkened consolidant from the wall painting and restored the original matt appearance of the painted surface. In another application on the painted ceiling of the same temple, the hydrogel was tested for removing thick soot layers. The hydrogel formulation (loaded with 5% ammonia, 0.3% ammonium carbonate, and 0.3% EDTA) removed these layers with no noticeable damage to the paint layers. In a wide-scale application of the hydrogel (loaded with 10% propylene carbonate), it removed a highly deteriorated varnish layer from a 19-c wall painting. All the traditional cleaning methods employed caused damage to the paint layers, proving that gel cleaning can be a safer cleaning alternative in some cases. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ admin @ c:irua:183381 |
Serial |
7671 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Echelpoel, R.; Kranenburg, R.; van Asten, A.; De Wael, K. |
|
|
Title |
Electrochemical detection of MDMA and 2C-B in ecstasy tablets using a selectivity enhancement strategy by in-situ derivatization |
Type |
A1 Journal article |
|
Year |
2022 |
Publication |
Forensic chemistry |
Abbreviated Journal |
|
|
|
Volume |
27 |
Issue |
|
Pages |
100383 |
|
|
Keywords |
A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab) |
|
|
Abstract |
Forensic drug laboratories are confronted with increasing amounts of drugs and a demand for faster results that are directly available on-site. In addition, the drug market is getting more complex with hundreds of new psychoactive substances (NPS) entering the market in recent years. Rapid and on-scene presumptive drug testing therefore faces a shift from manual colorimetric tests towards approaches that can detect a wider range of components and process results automatically. Electrochemical detection offers these desired characteristics, making it a suitable candidate for on-site drug detection. In this study, a two-step electrochemical sensor is introduced for the detection of MDMA and 2C-B. Firstly, a direct electrochemical analysis was performed to detect MDMA. Validation experiments on over 70 substances revealed that 2C-B was the only frequently encountered drug that gave a false positive result for MDMA in this first analysis. A second step using in-situ derivatization was subsequently introduced. To this end, formaldehyde was used for N-methylation of 2C-B thereby enhancing its electrochemical profile. The enriched electrochemical fingerprint in the second step allowed for clear differentiation between MDMA and 2C-B. The applicability of this approach was demonstrated with 71 ecstasy tablets seized by the Amsterdam Police. The MDMA/2C-B sensor correctly identified all 39 MDMA-containing tablets and 10 out of 11 tablets containing 2C-B. Most notably, correct results were also obtained for dark colored tablets in which both spectroscopic analysis and colorimetric tests failed due to obscured signals. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000725708200002 |
Publication Date |
2021-11-23 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2468-1709 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.7 |
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
|
Approved |
Most recent IF: 2.7 |
|
|
Call Number |
UA @ admin @ c:irua:183340 |
Serial |
7149 |
|
Permanent link to this record |
|
|
|
|
Author |
Drăgan, A.-M.; Parrilla, M.; Feier, B.; Oprean, R.; Cristea, C.; De Wael, K. |
|
|
Title |
Analytical techniques for the detection of amphetamine-type substances in different matrices : a comprehensive review |
Type |
A1 Journal article |
|
Year |
2021 |
Publication |
Trac-Trends In Analytical Chemistry |
Abbreviated Journal |
Trac-Trend Anal Chem |
|
|
Volume |
145 |
Issue |
|
Pages |
116447 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab) |
|
|
Abstract |
This current review focuses on contributions to amphetamine-type substances (ATS) analysis. This type of synthetic illicit drugs has been increasingly present worldwide reaching 5% of the market on illicit drugs in 2019. The increment of their production in many clandestine laboratories and easy distribution among society are two of the main concerns towards the battle against synthetic drugs. Therefore, the first part of this review details the classification and mechanism of action of ATS in the human body. Second, the pharmacological and toxicological effects of ATS on human health are described to motivate the need of early detection of ATS. Subsequently, the most used laboratory-based and portable methods are presented and critically discussed along the review. Finally, a careful discussion on the advantages and disadvantages of portable techniques employed on the field are addressed as potential tools for on-site ATS detection by law enforcement officers. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000723747000009 |
Publication Date |
2021-09-30 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0165-9936; 1879-3142 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
8.442 |
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
|
Approved |
Most recent IF: 8.442 |
|
|
Call Number |
UA @ admin @ c:irua:183268 |
Serial |
7460 |
|
Permanent link to this record |
|
|
|
|
Author |
Vekemans, B.; Janssens, K.; Vincze, L.; Aerts, A.; Adams, F.; Hertogen, J. |
|
|
Title |
Automated segmentation of μ-XRF image sets |
Type |
A1 Journal article |
|
Year |
1997 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
X-Ray Spectrom |
|
|
Volume |
26 |
Issue |
|
Pages |
333-346 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1997YG79300005 |
Publication Date |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.298 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 1.298; 1997 IF: 1.307 |
|
|
Call Number |
UA @ admin @ c:irua:18319 |
Serial |
5486 |
|
Permanent link to this record |
|
|
|
|
Author |
Aerts, A.; Janssens, K.; Adams, F. |
|
|
Title |
A chemical investigation of altered Chinese jade art objects |
Type |
H3 Book chapter |
|
Year |
1997 |
Publication |
|
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
170-171 |
|
|
Keywords |
H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ admin @ c:irua:18317 |
Serial |
5515 |
|
Permanent link to this record |
|
|
|
|
Author |
Janssens, K.; Adams, F. |
|
|
Title |
Microscopic X-ray fluorescence analysis at second and third generation synchrotron sources |
Type |
A3 Journal article |
|
Year |
1997 |
Publication |
Debye Institute synchrotron chronicle |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
2 |
Pages |
9-14 |
|
|
Keywords |
A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ admin @ c:irua:18303 |
Serial |
5727 |
|
Permanent link to this record |
|
|
|
|
Author |
Blidar, A.-M. |
|
|
Title |
The development of sensitive and selective electrochemical methods for the detection of antibiotics |
Type |
Doctoral thesis |
|
Year |
2021 |
Publication |
|
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
139 p. |
|
|
Keywords |
Doctoral thesis; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab) |
|
|
Abstract |
The discovery of antibiotics represented one of the greatest breakthroughs in medicine. Their success combined with an increasing intensive use is apparently bound to be also their undoing. This is due to the development of acquired antibiotic resistance, leading to inefficient antibiotherapy and even to the impossibility of treatment and death. The development and spread of antibiotic resistance are fueled by the widespread presence of trace levels of antibiotics residue, in various media, from environment to aliments. One of the solutions is the rigorous monitoring of the levels of antibiotics, which in term requires an almost constant development of new, more accessible analytical methods, especially screening methods, capable of decentralized analysis. In this direction, the electrochemical detection of antibiotics represents a very viable alternative. In this context, the aim of this thesis was to develop new electrochemical methods for the detection of antibiotics by employing and expanding on several strategies, like biomimetic sensors and electrochemical fingerprinting. Five studies were described in this thesis, that can be roughly divided in three categories, based on the analytical strategy employed. The first group is represented by direct electrochemical methods. The second group focuses on the use of biomimetic elements, molecularly imprinted polymers and aptamers. The hyphenation of electrochemical methods with other analytical methods was explored in the last group. In the last study, included in this group, the singlet oxygen-based photoelectrochemical approach was used for the detection of a phenolic antibiotic, rifampicin. The originality of the thesis consists in the testing and development of new approaches to various strategies used in electrochemical detection, revealing new insights in the field of electrochemical detection of antibiotics. The complex electrochemical fingerprint and the mechanism of the electrochemical oxidation were created and investigated, respectively, for the antibiotic vancomycin. New sensitive nanoplatforms were prepared by employing and combining new protocols. Additionally, important contributions were brought through the study involving the singlet oxygen-based detection of rifampicin. We demonstrated how a photocatalyst can exhibit analyte selectivity by strongly interacting with a complex phenolic compound, rifampicin. Summing up, the studies presented in this thesis will have an important impact in the field of electrochemical detection of antibiotics. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ admin @ c:irua:182955 |
Serial |
7804 |
|
Permanent link to this record |
|
|
|
|
Author |
Gomes, N.O.; Mendonça, C.D.; Machado, S.A.S.; Oliveira, O.N., Jr.; Raymundo-Pereira, P.A. |
|
|
Title |
Flexible and integrated dual carbon sensor for multiplexed detection of nonylphenol and paroxetine in tap water samples |
Type |
A1 Journal article |
|
Year |
2021 |
Publication |
Microchimica Acta |
Abbreviated Journal |
Microchim Acta |
|
|
Volume |
188 |
Issue |
10 |
Pages |
359 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab) |
|
|
Abstract |
Multiplex detection of emerging pollutants is essential to improve quality control of water treatment plants, which requires portable systems capable of real-time monitoring. In this paper we describe a flexible, dual electrochemical sensing device that detects nonylphenol and paroxetine in tap water samples. The platform contains two voltammetric sensors, with different working electrodes that were either pretreated or functionalized. Each working electrode was judiciously tailored to cover the concentration range of interest for nonylphenol and paroxetine, and square wave voltammetry was used for detection. An electrochemical pretreatment with sulfuric acid on the printed electrode enabled a selective detection of nonylphenol in 1.0-10 x 10(-6) mol L-1 range with a limit of detection of 8.0 x 10(-7) mol L-1. Paroxetine was detected in the same range with a limit of detection of 6.7 x 10(-7) mol L-1 using the printed electrode coated with a layer of carbon spherical shells. Simultaneous detection of the two analytes was achieved in tap water samples within 1 min, with no fouling and no interference effects. The long-term monitoring capability of the dual sensor was demonstrated in phosphate buffer for 45 days. This performance is statistically equivalent to that of high-performance liquid chromatography (HPLC) for water analysis. The dual-sensor platform is generic and may be extended to other water pollutants and clinical biomarkers in real-time monitoring of the environment and health conditions. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000702722700001 |
Publication Date |
2021-10-01 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0026-3672; 1436-5073 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
4.58 |
Times cited |
|
Open Access |
Not_Open_Access |
|
|
Notes |
|
Approved |
Most recent IF: 4.58 |
|
|
Call Number |
UA @ admin @ c:irua:182649 |
Serial |
7973 |
|
Permanent link to this record |
|
|
|
|
Author |
Alvarez-Martin, A.; Newsome, G.A.; Janssens, K. |
|
|
Title |
High-resolution mass spectrometry and nontraditional mass defect analysis of brominated historical pigments |
Type |
A1 Journal article |
|
Year |
2021 |
Publication |
Analytical Chemistry |
Abbreviated Journal |
Anal Chem |
|
|
Volume |
93 |
Issue |
44 |
Pages |
14851-14858 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp X-ray Imaging and Spectroscopy (AXIS) |
|
|
Abstract |
The implementation of high-resolution mass spectrometry systems offers new possibilities for the analysis of complex art samples such as historical oil paintings. However, these multicomponent systems generate large and complex data sets that require advanced visualization tools to aid interpretation, especially when no chromatographic separation is performed. In the context of this research, it was crucial to propose a data analysis tool to identify the products generated during the synthesis, drying, and aging of historical pigments. This study reports for the first time a nontraditional mass defect analysis of oil paint samples containing a fugitive brominated-organic pigment, eosin or geranium lake, by using direct infusion electrospray ionization in combination with a high-resolution Orbitrap mass spectrometer. The use of nontraditional Kendrick mass defect plots is presented in this study as a processing and visualization tool to recognize brominated species based on their specific mass defect and isotope pattern. The results demonstrate that this approach could provide valuable molecular compositional information on the degradation pathways of this pigment. We anticipate that mass defect analysis will become highly relevant in future degradation studies of many more historical organic pigments. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000718171600037 |
Publication Date |
2021-10-29 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2700; 5206-882x |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
6.32 |
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
|
Approved |
Most recent IF: 6.32 |
|
|
Call Number |
UA @ admin @ c:irua:182347 |
Serial |
8038 |
|
Permanent link to this record |
|
|
|
|
Author |
Alvarez-Martin, A.; McHugh, K.; Martin, C.; Kavich, G.; Kaczkowski, R. |
|
|
Title |
Understanding air-tight case environments at the National Museum of the American Indian (Smithsonian Institution) by SPME-GC-MS analysis |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Journal Of Cultural Heritage |
Abbreviated Journal |
J Cult Herit |
|
|
Volume |
44 |
Issue |
|
Pages |
38-46 |
|
|
Keywords |
A1 Journal article; Art; History; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Some volatile organic compounds (VOCs), generated and accumulated in exhibition cases, are capable of inducing degradation in historical artifacts. In this context, it is of special importance to distinguish between VOCs emitted by the construction materials and/or the historical objects, with the ultimate goal of proposing an appropriate mitigation strategy. To pursue this goal, a comprehensive analysis based on solid phase microextraction (SPME) coupled to gas chromatography-mass spectrometry (GC-MS) has been optimized. The sampling setup used in this study does not require any modification of the exhibition design, and the testing remained nearly invisible and unobtrusive to museum visitors. This methodology has been applied to an issue encountered at the National Museum of the American Indian (Smithsonian Institution), where an unpleasant smell was detected in airtight exhibition cases already on display containing sensitive historical objects. The analysis of the volatiles emitted by construction materials allowed for identification of characteristic markers emitted by each material, and the ability to identify their overall contribution in the exhibition case. Via this method, SPME-GC-MS confirmed via the detection of some specific markers that the unpleasant smell was released by one of the construction materials and had accumulated in the exhibition case. In addition, due to the measurements taken in different positions around the exhibition cases, results were useful to point out the range of efficiency of the sorbent material placed in some of the exhibition cases as a first attempt of mitigation technique. (C) 2020 Elsevier Masson SAS. All rights reserved. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000560473700004 |
Publication Date |
2020-02-06 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1296-2074 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
3.1 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 3.1; 2020 IF: 1.838 |
|
|
Call Number |
UA @ admin @ c:irua:181927 |
Serial |
8706 |
|
Permanent link to this record |
|
|
|
|
Author |
Newsome, G.A.; Kavich, G.; Alvarez-Martin, A. |
|
|
Title |
Interface for reproducible, multishot direct analysis of solid-phase microextraction samples |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Analytical Chemistry |
Abbreviated Journal |
Anal Chem |
|
|
Volume |
92 |
Issue |
6 |
Pages |
4182-4186 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
An enclosed interface that joins a direct analysis in real time (DART) probe, solid-phase microextraction (SPME) fiber, and the inlet of a high-resolution mass spectrometer is described. Unlike other systems to couple SPME sampling to ambient mass spectrometry, the interface is able to perform discrete analyses on different areas of a single SPME fiber device for up to three technical replicate measurements of one sampling event. Inlet flow speed and desorption temperature are optimized, and reproducibility is demonstrated between replicate analyses on the same derivatized SPME fiber and with sequential fiber sampling events, yielding analyte measurement center of variance (CV) from 3 to 6%. Conditioning is also performed with the enclosed DART. The interface is a straightforward addition to commercially available technologies, and machine diagrams for custom components operated with SPME/DART/MS equipment are included. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000526563900004 |
Publication Date |
2020-02-07 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2700; 5206-882x |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
7.4 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 7.4; 2020 IF: 6.32 |
|
|
Call Number |
UA @ admin @ c:irua:181926 |
Serial |
8113 |
|
Permanent link to this record |
|
|
|
|
Author |
Alvarez-Martin, A.; George, J.; Kaplan, E.; Osmond, L.; Bright, L.; Newsome, G.A.; Kaczkowski, R.; Vanmeert, F.; Kavich, G.; Heald, S. |
|
|
Title |
Identifying VOCs in exhibition cases and efflorescence on museum objects exhibited at Smithsonian’s National Museum of the American Indian-New York |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Heritage science |
Abbreviated Journal |
|
|
|
Volume |
8 |
Issue |
1 |
Pages |
115 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Two mass spectrometry (MS) methods, solid-phase microextraction gas chromatography (SPME–GC–MS) and direct analysis in real time (DART-MS), have been explored to investigate widespread efflorescence observed on exhibited objects at the Smithsonian’s National Museum of the American Indian in New York (NMAI-NY). Both methods show great potential, in terms of speed of analysis and level of information, for identifying the organic component of the efflorescence as 2,2,6,6-tetramethyl-4-piperidinol (TMP-ol) emitted by the structural adhesive (Terostat MS 937) used for exhibit case construction. The utility of DART-MS was proven by detecting the presence of TMP-ol in construction materials in a fraction of the time and effort required for SPME–GC–MS analysis. In parallel, an unobtrusive SPME sampling strategy was used to detect volatile organic compounds (VOCs) accumulated in the exhibition cases. This sampling technique can be performed by collections and conservation staff at the museum and shipped to an off-site laboratory for analysis. This broadens the accessibility of MS techniques to museums without access to instrumentation or in-house analysis capabilities. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000589423700001 |
Publication Date |
2020-11-14 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2050-7445 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.5 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 2.5; 2020 IF: NA |
|
|
Call Number |
UA @ admin @ c:irua:181925 |
Serial |
8056 |
|
Permanent link to this record |
|
|
|
|
Author |
Alvarez-Martin, A.; Kavich, G. |
|
|
Title |
SPME-GC–MS for the off-gassing analysis of a complex museum object |
Type |
A1 Journal article |
|
Year |
2021 |
Publication |
Microchemical Journal |
Abbreviated Journal |
Microchem J |
|
|
Volume |
167 |
Issue |
|
Pages |
106276 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp X-ray Imaging and Spectroscopy (AXIS) |
|
|
Abstract |
The identification of volatile organic compounds (VOCs) emitted by a complex museum object, composed of materials of different nature, has been optimized by solid-phase microextraction coupled to gas chromatography-mass spectrometry (SPME-GC–MS). The performance of two fiber coatings and four sampling times were tested and compared in order to define the best sampling conditions. The method allowed a fair extraction of volatile and semivolatile compounds emitted naturally by the object, without any type of accelerating aging. In addition, on-fiber derivatization was applied to improve the extraction efficiency and reduce the sampling time of harmful carboxylic acids emitted by the object. The results obtained are of prime importance to show the off-gassing activity of a valuable museum object in order to take further decisions related with its storage and display conditions. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000662640500001 |
Publication Date |
2021-04-21 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0026-265x; 0026-265x |
ISBN |
|
Additional Links |
UA library record; WoS full record |
|
|
Impact Factor |
3.034 |
Times cited |
|
Open Access |
Not_Open_Access |
|
|
Notes |
|
Approved |
Most recent IF: 3.034 |
|
|
Call Number |
UA @ admin @ c:irua:181924 |
Serial |
8577 |
|
Permanent link to this record |
|
|
|
|
Author |
Alvarez-Martin, A.; Wilcop, M.; Anderson, R.; Wendt, D.; Barden, R.; Kavich, G.M. |
|
|
Title |
Investigation of volatile organic compounds in museum storage areas |
Type |
A1 Journal article |
|
Year |
2021 |
Publication |
Air Quality Atmosphere And Health |
Abbreviated Journal |
Air Qual Atmos Hlth |
|
|
Volume |
14 |
Issue |
11 |
Pages |
1797-1809 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp X-ray Imaging and Spectroscopy (AXIS) |
|
|
Abstract |
This study investigates the complex mixture of volatile organic compounds (VOCs) released by and accumulated within a collection of historic medicinal, pharmaceutical, and cosmetic artifacts housed at the National Museum of American History (Smithsonian Institution). In recent years, staff have become concerned, both for the safety of the objects and for personnel working in the collection, about strong unremediated odors accumulating within several storage cabinets. Museum staff also wondered if non-odorous off-gassing might need remediation. Solid-phase microextraction combined with gas chromatography–mass spectrometry analysis (SPME–GC–MS) was used to identify VOCs present in the storage room housing the collection. Over 160 compounds were detected and identified overall. Among these, 49 appeared to be directly related to ingredients used in the manufacture of many collection items. The results of the study suggest that SPME–GC–MS can be a strong tool for the rapid screening of multicomponent museum collections exhibiting off-gassing problems, before the pursuit of other more tedious analytical approaches. Additionally, the study reveals valuable insight into the characteristic volatile emission of historic medicinal, pharmaceutical, and cosmetic artifacts, increasing understanding of, and decision-making for, similar collections of objects. Eventually, it is hoped that this information can be used to inform mitigation strategies for the capture and reduction of VOCs in collections storage areas. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000659058300001 |
Publication Date |
2021-06-08 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1873-9318 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
3.184 |
Times cited |
|
Open Access |
Not_Open_Access |
|
|
Notes |
|
Approved |
Most recent IF: 3.184 |
|
|
Call Number |
UA @ admin @ c:irua:181923 |
Serial |
8129 |
|
Permanent link to this record |
|
|
|
|
Author |
Muhammad, S.; Wuyts, K.; De Wael, K.; Samson, R. |
|
|
Title |
Does leaf micro-morphology influence the recognition of particles on SEM images? |
Type |
A3 Journal article |
|
Year |
2021 |
Publication |
International Journal of Environmental Pollution and Remediation |
Abbreviated Journal |
|
|
|
Volume |
9 |
Issue |
|
Pages |
22-37 |
|
|
Keywords |
A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab) |
|
|
Abstract |
Scanning electron microscopy (SEM) remains a popular approach to determine the shape, size, density and elemental composition of particles collected on leaf surfaces, but the effect of leaf micro-morphology on particle counts is not very well known. In this study, leaves of sixteen urban plant species were examined for particle density in June and September 2016 using SEM. The investigated plant species differed in leaf micro-morphology involving trichomes, raised stomata, epicuticular wax crystals and convex epidermal cells forming deep grooves between cells. The particle density on leaves of the investigated plant species was estimated by particle size fraction and leaf side. Particle density was significantly higher on the adaxial (AD) leaf side compared to the abaxial (AB) leaf side and higher for fine-particles than coarse-particles. The effect of trichome density on particle density of the AB and the AD leaf side was indicated to be significant and positive for both coarse and fine-particles in June but not in September. The successive repeated measurements elucidated that features constructing the topography of a leaf surface such as trichomes, stomata, and epidermal cells frequently contributed towards the edge enhancement effect, resulting in exaggerated particle counts. Besides, the mechanical drift contributed to the disparity in particle density measurements. Lastly, the reduction in particle density between successive measurements were imputed on the charging effect. These results enable us to suggest that in addition to characterization of micro-morphological features on a leaf surface, SEM will continue to be a useful approach for determining the particle: shape, size, elemental composition and density of the deposited particles. Nonetheless, the disparity in particle density measurements can occur due to abnormal particle recognition. Based on the results of September, we recommend that within-session successive repeated measurements (~ n ≥ 5) need to be performed to remove measurement uncertainties and obtain reliable quantitative data of particle counts using SEM. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2021-09-15 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
|
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ admin @ c:irua:181797 |
Serial |
7822 |
|
Permanent link to this record |
|
|
|
|
Author |
Trashin, S.; Morales-Yánez, F.; Thiruvottriyur Shanmugam, S.; Paredis, L.; Carrión, E.N.; Sariego, I.; Muyldermans, S.; Polman, K.; Gorun, S.M.; De Wael, K. |
|
|
Title |
Nanobody-based immunosensor detection enhanced by photocatalytic-electrochemical redox cycling |
Type |
A1 Journal article |
|
Year |
2021 |
Publication |
Analytical Chemistry |
Abbreviated Journal |
Anal Chem |
|
|
Volume |
93 |
Issue |
40 |
Pages |
13606-13614 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab) |
|
|
Abstract |
Detection of antigenic biomarkers present in trace amounts is of crucial importance for medical diagnosis. A parasitic disease, human toxocariasis, lacks an adequate diagnostic method despite its worldwide occurrence. The currently used serology tests may stay positive even years after a possibly unnoticed infection, whereas the direct detection of a re-infection or a still active infection remains a diagnostic challenge due to the low concentration of circulating parasitic antigens. We report a time-efficient sandwich immunosensor using small recombinant single-domain antibodies (nanobodies) derived from camelid heavy-chain antibodies specific to Toxocara canis antigens. An enhanced sensitivity to pg/mL levels is achieved by using a redox cycle consisting of a photocatalytic oxidation and electrochemical reduction steps. The photocatalytic oxidation is achieved by a photosensitizer generating singlet oxygen (1O2) that, in turn, readily reacts with p-nitrophenol enzymatically produced under alkaline conditions. The photooxidation produces benzoquinone that is electrochemically reduced to hydroquinone, generating an amperometric response. The light-driven process could be easily separated from the background, thus making amperometric detection more reliable. The proposed method for detection of the toxocariasis antigen marker shows superior performances compared to other detection schemes with the same nanobodies and outperforms by at least two orders of magnitude the assays based on regular antibodies, thus suggesting new opportunities for electrochemical immunoassays of challenging low levels of antigens. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000708550500025 |
Publication Date |
2021-09-29 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2700; 5206-882x |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
6.32 |
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
|
Approved |
Most recent IF: 6.32 |
|
|
Call Number |
UA @ admin @ c:irua:181795 |
Serial |
8290 |
|
Permanent link to this record |
|
|
|
|
Author |
Al-Emam, E.; Beltran, V.; De Meyer, S.; Nuyts, G.; Wetemans, V.; De Wael, K.; Caen, J.; Janssens, K. |
|
|
Title |
Removal of a past varnish treatment from a 19th-century Belgian wall painting by means of a solvent-loaded double network hydrogel |
Type |
A1 Journal article |
|
Year |
2021 |
Publication |
Polymers |
Abbreviated Journal |
Polymers-Basel |
|
|
Volume |
13 |
Issue |
16 |
Pages |
2651-20 |
|
|
Keywords |
A1 Journal article; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab); Antwerp X-ray Imaging and Spectroscopy (AXIS) |
|
|
Abstract |
Polymeric materials have been used by painting conservator-restorers as consolidants and/or varnishes for wall paintings. The application of these materials is carried out when confronting loose paint layers or as a protective coating. However, these materials deteriorate and cause physiochemical alterations to the treated surface. In the past, the monumental neo-gothic wall painting 'The Last Judgment' in the chapel of Sint-Jan Berchmanscollege in Antwerp, Belgium was treated with a synthetic polymeric material. This varnish deteriorated significantly and turned brown, obscuring the paint layers. Given also that the varnish was applied to some parts of the wall painting and did not cover the entire surface, it was necessary to remove it in order to restore the original appearance of the wall painting. Previous attempts carried out by conservator-restorers made use of traditional cleaning methods, which led to damage of the fragile paint layers. Therefore, gel cleaning was proposed as a less invasive and more controllable method for gently softening and removing the varnish. The work started by identifying the paint stratigraphy and the deteriorated varnish via optical microscopy (OM), scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy (SEM-EDX), X-ray diffraction (XRD), and Fourier-transform infrared (FTIR) spectroscopy. A polyvinyl alcohol-borax/agarose (PVA-B/AG) hydrogel loaded with a number of solvents/solvent mixtures was employed in a series of tests to select the most suitable hydrogel composite. By means of the hydrogel composite loaded with 10% propylene carbonate, it was possible to safely remove the brown varnish layer. The results were verified by visual examinations (under visible light 'VIS' and ultraviolet light 'UV') as well as OM and FTIR spectroscopy. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000690248000001 |
Publication Date |
2021-08-10 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2073-4360 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
3.364 |
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
|
Approved |
Most recent IF: 3.364 |
|
|
Call Number |
UA @ admin @ c:irua:181567 |
Serial |
8470 |
|
Permanent link to this record |
|
|
|
|
Author |
Parrilla, M.; Joosten, F.; De Wael, K. |
|
|
Title |
Enhanced electrochemical detection of illicit drugs in oral fluid by the use of surfactant-mediated solution |
Type |
A1 Journal article |
|
Year |
2021 |
Publication |
Sensors And Actuators B-Chemical |
Abbreviated Journal |
Sensor Actuat B-Chem |
|
|
Volume |
348 |
Issue |
|
Pages |
130659 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab) |
|
|
Abstract |
Illicit drug consumption is a worldwide worrying phenomenon that troubles modern society. For this reason, law enforcement agencies (LEAs) are placing tremendous efforts into tackling the spreading of such substances among our community. New sensing technologies can facilitate the LEAs duties by providing portable and affordable analytical devices. Herein, we present for the first time a sensitive and low-cost electrochemical method, i.e. square-wave adsorptive stripping voltammetry on carbon screen-printed electrodes (SPE), for the detection of five illicit drugs (i.e. cocaine, heroin, 3,4-methylenedioxymethamphetamine, 4-chloro-alpha-pyrrolidinovalerophenone, and ketamine) in oral fluid by the aid of a surfactant. Particularly, the surfactant is adsorbed at the carbon electrode’s surface and yields the adsorption of illicit drug molecules, allowing for an enhanced electrochemical signal in comparison to surfactant-free media. First, the surfactant-mediated behavior is deeply explored at the SPE by cyclic voltammetry, electrochemical impedance spectroscopy, and Fourier-transform infrared spectroscopy. Subsequently, the electrochemical behavior of the five illicit drugs is studied and optimized to render optimal analytical performance. Accordingly, the analytical system exhibited a wide linear concentration range from 1 to 30 µM with sub-micromolar limits of detection and high sensitivity. This performance is similar to other reported electrochemical sensors, but with the advantage of using an unmodified SPE, thus avoiding costly and complex functionalization of the SPE. Finally, the methodology was evaluated in diluted oral fluid samples spiked with illicit drugs. Overall, this work describes a simple, rapid, portable, and sensitive method for the detection of illicit drugs aiming to provide oral fluid testing opportunities to LEAs. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000701915600005 |
Publication Date |
2021-08-27 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0925-4005 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
5.401 |
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
|
Approved |
Most recent IF: 5.401 |
|
|
Call Number |
UA @ admin @ c:irua:181307 |
Serial |
7912 |
|
Permanent link to this record |
|
|
|
|
Author |
Parrilla, M.; De Wael, K. |
|
|
Title |
Wearable self‐powered electrochemical devices for continuous health management |
Type |
A1 Journal article |
|
Year |
2021 |
Publication |
Advanced Functional Materials |
Abbreviated Journal |
Adv Funct Mater |
|
|
Volume |
31 |
Issue |
50 |
Pages |
2107042 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab) |
|
|
Abstract |
The wearable revolution is already present in society through numerous gadgets. However, the contest remains in fully deployable wearable (bio)chemical sensing. Its use is constrained by the energy consumption which is provided by miniaturized batteries, limiting the autonomy of the device. Hence, the combination of materials and engineering efforts to develop sustainable energy management is paramount in the next generation of wearable self-powered electrochemical devices (WeSPEDs). In this direction, this review highlights for the first time the incorporation of innovative energy harvesting technologies with top-notch wearable self-powered sensors and low-powered electrochemical sensors toward battery-free and self-sustainable devices for health and wellbeing management. First, current elements such as wearable designs, electrochemical sensors, energy harvesters and storage, and user interfaces that conform WeSPEDs are depicted. Importantly, the bottlenecks in the development of WeSPEDs from an analytical perspective, product side, and power needs are carefully addressed. Subsequently, energy harvesting opportunities to power wearable electrochemical sensors are discussed. Finally, key findings that will enable the next generation of wearable devices are proposed. Overall, this review aims to bring new strategies for an energy-balanced deployment of WeSPEDs for successful monitoring of (bio)chemical parameters of the body toward personalized, predictive, and importantly, preventive healthcare. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000694642500001 |
Publication Date |
2021-09-09 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1616-301x |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
12.124 |
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
|
Approved |
Most recent IF: 12.124 |
|
|
Call Number |
UA @ admin @ c:irua:181306 |
Serial |
8750 |
|
Permanent link to this record |
|
|
|
|
Author |
Koldeweij, J.; Hoogstede, L.; Ilsink, M.; Janssens, K.; De Keyser, N.; Gotink, R.K.; Legrand, S.; Nauhaus, J.M.; van der Snickt, G.; Spronk, R. |
|
|
Title |
The patron of Hieronymus Bosch's 'Last Judgment' triptych in Vienna |
Type |
A1 Journal article |
|
Year |
2018 |
Publication |
The Burlington magazine |
Abbreviated Journal |
|
|
|
Volume |
160 |
Issue |
1379 |
Pages |
106-111 |
|
|
Keywords |
A1 Journal article; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
A technical examination of the Last Judgment triptych by Hieronymus Bosch in the Paintings Gallery of the Academy of Fine Arts, Vienna, has revealed a painted escutcheon with the coat of arms of the Burgundian court official Hippolyte de Berthoz underneath the current surface of the right outer wing. This allows him to be firmly identified as the painting's patron. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000458246800007 |
Publication Date |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0007-6287; 2044-9925 |
ISBN |
|
Additional Links |
UA library record; WoS full record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:181267 |
Serial |
8656 |
|
Permanent link to this record |
|
|
|
|
Author |
Cagno, S.; Lind, O.C.; Popic, J.M.; Skipperud, L.; De Nolf, W.; Nuyts, G.; Vanmeert, F.; Jaroszewicz, J.; Janssens, K.; Salbu, B. |
|
|
Title |
Micro-analytical characterization of thorium-rich aggregates from Norwegian NORM sites (Fen Complex, Telemark) |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Journal Of Environmental Radioactivity |
Abbreviated Journal |
J Environ Radioactiv |
|
|
Volume |
219 |
Issue |
|
Pages |
106273 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
In this study we performed microscopic characterization of mineral particles that were collected in the thorium-rich Fen Complex in Norway and identified and isolated based on autoradiography in function of their radioactivity. For this we combined information obtained with X-ray absorption mu-CT, mu-XRF and mu-XRD, both in bi- and in three-dimensional (tomographic) mode. We demonstrate that radionuclides and metals are heterogeneously distributed both within soil samples and within individual Th-enriched aggregates, which are characterised as low-density mineral bulk particles with high density material inclusions, where Th as well as several metals are highly concentrated. For these sites, it is important to take into account how these inhomogeneous distributions could affect the overall environmental behaviour of Th and progeny upon weathering due to human or environmental factors. Moreover, the estimated size of the Th-containing inclusions as determined in this work represents information of importance for the characterization of radionuclides and toxic metals exposure, as well as for assessing the viability of mining for Th and rare-earth metals in the Fen Complex and the associated environmental impact. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000535130500005 |
Publication Date |
2020-04-27 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0265-931x |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.3 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 2.3; 2020 IF: 2.31 |
|
|
Call Number |
UA @ admin @ c:irua:181195 |
Serial |
8229 |
|
Permanent link to this record |
|
|
|
|
Author |
Sleegers, N. |
|
|
Title |
Cephalosporin antibiotics : electrochemical fingerprints and redox pathways investigated by mass spectral analysis |
Type |
Doctoral thesis |
|
Year |
2021 |
Publication |
|
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
208 p. |
|
|
Keywords |
Doctoral thesis; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ admin @ c:irua:181014 |
Serial |
7588 |
|
Permanent link to this record |