|
“Stabilized silicene within bilayer graphene : a proposal based on molecular dynamics and density-functional tight-binding calculations”. Berdiyorov GR, Neek-Amal M, Peeters FM, van Duin ACT, Physical review : B : condensed matter and materials physics 89, 024107 (2014). http://doi.org/10.1103/PhysRevB.89.024107
Abstract: Freestanding silicene is predicted to display comparable electronic properties as graphene. However, the yet synthesized silicenelike structures have been only realized on different substrates which turned out to exhibit versatile crystallographic structures that are very different from the theoretically predicted buckled phase of freestanding silicene. This calls for a different approach where silicene is stabilized using very weakly interacting surfaces. We propose here a route by using graphene bilayer as a scaffold. The confinement between the flat graphene layers results in a planar clustering of Si atoms with small buckling, which is energetically unfavorable in vacuum. Buckled hexagonal arrangement of Si atoms similar to freestanding silicene is observed for large clusters, which, in contrast to Si atoms on metallic surfaces, is only very weakly van der Waals coupled to the graphene layers. These clusters are found to be stable well above room temperature. Our findings, which are supported by density-functional tight-binding calculations, show that intercalating bilayer graphene with Si is a favorable route to realize silicene.
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 3.836
Times cited: 43
DOI: 10.1103/PhysRevB.89.024107
|
|
|
“Topological confinement in trilayer graphene”. de Sena SHR, Pereira JM, Peeters FM, Farias GA, Physical review : B : condensed matter and materials physics 89, 035420 (2014). http://doi.org/10.1103/PhysRevB.89.035420
Abstract: We calculate the spectrum of states that are localized at the interface between two regions of opposite bias in trilayer graphene (TLG). These potential profiles, also known as potential kinks, have been predicted to support two different branches of localized states for the case of bilayer graphene, and show similarities to the surface states of topological insulators. On the other hand, we found that ABC stacked TLG exhibits three different unidimensional branches of states in each valley that are confined to the kink interface. They have the property E(k(y)) = -E(-k(y)) when belonging to the same valley and E-K(k(y)) = -E-K' (-k(y)). A kink-antikink potential profile opens a gap in the spectrum of these one-dimensional states.
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 3.836
Times cited: 4
DOI: 10.1103/PhysRevB.89.035420
|
|
|
“Electronic and optical properties of core-shell nanowires in a magnetic field”. Ravi Kishore VV, Partoens B, Peeters FM, Journal of physics : condensed matter 26, 095501 (2014). http://doi.org/10.1088/0953-8984/26/9/095501
Abstract: The electronic and optical properties of zincblende nanowires are investigated in the presence of a uniform magnetic field directed along the [001] growth direction within the k . p method. We focus our numerical study on core-shell nanowires consisting of the III-V materials GaAs, AlxGa1-xAs and AlyGa1-y/0.51In0.49P. Nanowires with electrons confined in the core exhibit a Fock-Darwin-like spectrum, whereas nanowires with electrons confined in the shell show Aharonov-Bohm oscillations. Thus, by properly choosing the core and the shell materials of the nanowire, the optical properties in a magnetic field can be tuned in very different ways.
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 2.649
Times cited: 10
DOI: 10.1088/0953-8984/26/9/095501
|
|
|
“Electronic properties of graphene nano-flakes : energy gap, permanent dipole, termination effect, and Raman spectroscopy”. Singh SK, Neek-Amal M, Peeters FM, The journal of chemical physics 140, 074304 (2014). http://doi.org/10.1063/1.4865414
Abstract: The electronic properties of graphene nano-flakes (GNFs) with different edge passivation are investigated by using density functional theory. Passivation with F and H atoms is considered: C-Nc X-Nx (X = F or H). We studied GNFs with 10 < N-c < 56 and limit ourselves to the lowest energy configurations. We found that: (i) the energy difference Delta between the highest occupied molecular orbital and the lowest unoccupied molecular orbital decreases with N-c, (ii) topological defects (pentagon and heptagon) break the symmetry of the GNFs and enhance the electric polarization, (iii) the mutual interaction of bilayer GNFs can be understood by dipole-dipole interaction which were found sensitive to the relative orientation of the GNFs, (iv) the permanent dipoles depend on the edge terminated atom, while the energy gap is independent of it, and (v) the presence of heptagon and pentagon defects in the GNFs results in the largest difference between the energy of the spin-up and spin-down electrons which is larger for the H-passivated GNFs as compared to F-passivated GNFs. Our study shows clearly the effect of geometry, size, termination, and bilayer on the electronic properties of small GNFs. This study reveals important features of graphene nano-flakes which can be detected using Raman spectroscopy. (C) 2014 AIP Publishing LLC.
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 2.965
Times cited: 30
DOI: 10.1063/1.4865414
|
|
|
“Self-assembly of Janus particles confined in a channel”. Sobrino Fernandez M, Misko VR, Peeters FM, Physical review : E : statistical, nonlinear, and soft matter physics 89, 022306 (2014). http://doi.org/10.1103/PhysRevE.89.022306
Abstract: Janus particles present an important class of building blocks for directional assembly. These are compartmentalized colloids with two different hemispheres. Here, we consider a two-dimensional model of Janus disks consisting of a hydrophobic semicircle and an electro-negatively charged one. Placed in a solution, the hydrophobic sides will attract each other while the charged sides will give rise to a repulsive force. Using molecular dynamics simulations, we study the morphology of these particles when confined in a channel-like environment using a one dimensional harmonic confinement potential. The interest to this system is first of all due to the fact that it could serve as a simple model for membrane formation. Indeed, the recently synthesized new class of artificial amphiphiles, known as Janus dendrimers, were shown to self-assemble in bilayer structures mimicking biological membranes. In turn, Janus particles that combine the amphiphilicity and colloidal rigidity serve as a good model for Janus dendrimers. A variety of ordered membrane-like morphologies are found consisting of single and multiple chain configurations with different orientations of the particles with respect to each other that we summarize in a phase diagram.
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 2.366
Times cited: 11
DOI: 10.1103/PhysRevE.89.022306
|
|
|
“Polyethylene glycol conjugated polymeric nanocapsules for targeted delivery of quercetin to folate-expressing cancer cells in vitro and in vivo”. El-Gogary RI, Rubio N, Wang JTW, Al-Jamal WT, Bourgognon M, Kafa H, Naeem M, Klippstein R, Abbate V, Leroux F, Bals S, Van Tendeloo G, Kamel AO, Awad GAS, Mortada ND, Al-Jamal KT;, ACS nano 8, 1384 (2014). http://doi.org/10.1021/nn405155b
Abstract: In this work we describe the formulation and characterization of chemically modified polymeric nanocapsules incorporating the anticancer drug, quercetin, for the passive and active targeting to tumors. Folic acid was conjugated to poly(lactide-co-glycolide) (PLGA) polymer to facilitate active targeting to cancer cells. Two different methods for the conjugation of PLGA to folic acid were employed utilizing polyethylene glycol (PEG) as a spacer. Characterization of the conjugates was performed using FTIR and H-1 NMR studies. The PEG and folk acid content was independent of the conjugation methodology employed. PEGylation has shown to reduce the size of the nanocapsule; moreover, zeta-potential was shown to be polymer-type dependent. Comparative studies on the cytotoxicity and cellular uptake of the different formulations by He La cells, in the presence and absence of excess folic acid, were carried out using MTT assay and Confocal Laser Scanning Microscopy, respectively. Both results confirmed the selective uptake and cytotoxicity of the folic acid targeted nanocapsules to the folate enriched cancer cells in a folate-dependent manner. Finally, the passive tumor accumulation and the active targeting of the nanocapsules to folate-expressing cells were confirmed upon intravenous administration in He La or IGROV-1 tumor-bearing mice. The developed nanocapsules provide a system for targeted delivery of a range of hydrophobic anticancer drugs in vivo.
Keywords: A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT)
Impact Factor: 13.942
Times cited: 144
DOI: 10.1021/nn405155b
|
|
|
“Deeply colored and black-appearing Roman glass : a continued research”. Cagno S, Cosyns P, Izmer A, Vanhaecke F, Nys K, Janssens K, Journal of archaeological science 42, 128 (2014). http://doi.org/10.1016/J.JAS.2013.11.003
Abstract: In the context of archaeological and historical assessment of Roman black-appearing glass, the chemical and physical characterization of a large collection of samples originating from various areas of the Roman Empire has been gathered over the past years to (i) verify whether a minor segment of the overall Roman glass production can help in determining possible diachronic changes in Roman imperial glass production (1st century AD – 5th century AD) and (ii) reveal regional compositional differences. In this paper, the latest results on the chemical composition of an additional 44 black-appearing Roman glass samples are presented, together with general conclusions based upon the entire compositional dataset of over 400 analyzed black glass samples. The results show that the Roman black glass is obtained through several glass compositions with a specific chronological, geographical and typological distribution. (C) 2013 Elsevier Ltd. All rights reserved.
Keywords: A1 Journal article; Philosophy; History; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.602
Times cited: 18
DOI: 10.1016/J.JAS.2013.11.003
|
|
|
“Landau-level dispersion and the quantum Hall plateaus in bilayer graphene”. Zarenia M, Vasilopoulos P, Pourtolami N, Peeters FM, AIP conference proceedings 1566, 275 (2013). http://doi.org/10.1063/1.4848392
Abstract: We study the quantum Hall effect (QHE) in bilayer graphene using the Kubo-Greenwood formula. At zero temperature the Hall conductivity sigma(yx) is given by sigma(yx) – 4(N + 1)e(2)/h with N the index of the highest occupied Landau level (LL). Including the dispersion of the LLs and their width, due to e. g. scattering by impurities, produces the plateau of the n = 0 LL in agreement with experimental results on doped samples and similar theoretical results on single-layer graphene plateaus widen with impurity concentration. Further, the evaluated resistivity rho(xx) exhibits a strong, oscillatory dependence on the electron concentration. Explicit results are obtained for delta-function impurities.
Keywords: P1 Proceeding; Condensed Matter Theory (CMT)
DOI: 10.1063/1.4848392
|
|
|
“Global and local superconductivity in boron-doped granular diamond”. Zhang G, Turner S, Ekimov EA, Vanacken J, Timmermans M, Samuely T, Sidorov VA, Stishov SM, Lu Y, Deloof B, Goderis B, Van Tendeloo G, Van de Vondel J, Moshchalkov VV;, Advanced materials 26, 2034 (2014). http://doi.org/10.1002/adma.201304667
Abstract: Strong granularity-correlated and intragrain modulations of the superconducting order parameter are demonstrated in heavily boron-doped diamond situated not yet in the vicinity of the metal-insulator transition. These modulations at the superconducting state (SC) and at the global normal state (NS) above the resistive superconducting transition, reveal that local Cooper pairing sets in prior to the global phase coherence.
Keywords: A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT)
Impact Factor: 19.791
Times cited: 34
DOI: 10.1002/adma.201304667
|
|
|
“The determination of silicon in steel by 14-mev neutron activation analysis”. van Grieken R, Gijbels R, Speecke A, Hoste J, Analytica chimica acta 43, 199 (1968). http://doi.org/10.1016/S0003-2670(00)89208-9
Abstract: A fast (25 min) non-destructive determination of silicon in steel by 14-MeV neutron activation is described. The 1.78-MeV 28Al activity, induced by the reaction 28Si(n,p)28Al, is counted on a NaI(Tl) detector. An oxygen flux monitor is used to normalise to the same neutron flux. Two methods are described to correct for the 56Mn activity (2.58 h), induced into the iron matrix via 56Fe(n,p)56Mn. Nuclear interferences of phosphorus and aluminium have been examined. Special attention has been paid to stainless steels. A sensitivity of 0.02 to 0.05% of silicon is obtained. The precision is 2 to 3% for steels containing above 1% silicon, and 7% for 0.1% of silicon.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 19
DOI: 10.1016/S0003-2670(00)89208-9
|
|
|
“Internal standard activation analysis of silicon in steel”. van Grieken R, Gijbels R, Speecke A, Hoste J, Analytica chimica acta 43, 381 (1968). http://doi.org/10.1016/S0003-2670(00)89235-1
Abstract: Non-destructive 14-MeV neutron activation analysis for silicon in steel has been applied with 56Mn as internal standard.56Mn is formed from the iron matrix via the 56Fe(n,p)56Mn reaction. Several methods of internal standardisation via56Mn are discussed. The 0.84-MeV photopeak of 56Mn is recommended if steel samples of about the same composition are to be analysed. Chemically analysed steel samples are used as silicon standards. A precision of 0.7% was obtained for an analysis plus standardisation time of 13 min. Special attention was paid to interferences produced by concentration changes of impurity elements. Several possible sources of errors were investigated.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 14
DOI: 10.1016/S0003-2670(00)89235-1
|
|
|
“The determination of copper in iron and steel by 14-Mev neutron activation analysis”. Van Grieken R, Speecke A, Hoste J, Analytica chimica acta 51, 151 (1970). http://doi.org/10.1016/S0003-2670(01)95703-4
Abstract: A fast (10 min) non-destructive determination of copper in. steel and cast iron by 14-MeV neutron activation analysis is described. The 0.511-MeV annihilation radiation of62Cu (T1/2=9.8 min), induced by the reaction63Cu(n,2n)62Cu, is counted by two opposing NaI(Tl) detectors operating in coincidence. An oxygen flux monitor is used to normalise the irradiations. For high phosphorus contents, two measurements are made and the 9-min activity contribution is calculated. As the iron content of the samples is known, the use of pure iron samples allows correction for53Fe activity from the reaction54Fe(n,2n)53Fe(T1/2= 8.9 min). When the phosphorus and silicon activities are low, the procedure of counting and computing can be greatly simplified. Nuclear interferences of most common alloying and impurity elements were investigated.The precision is 23% for steels containing above 1% Cu, andCa. 10% for 0.1%Cu.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)95703-4
|
|
|
“On the precision of oxygen determinations in steel by 14-MeVv neutron activation”. Van Grieken R, Speecke A, Hoste J, Analytica chimica acta 52, 275 (1970). http://doi.org/10.1016/S0003-2670(01)80957-0
Abstract: The precision of the 14-MeV neutron activation determination of oxygen in steel has been examined as a function of the oxygen content for a large number of steel and cast iron samples. The experimental and the statistically expected standard deviations have been compared. In the conditions used, 2.5 counts from 16N were registered for each p.p.m. of oxygen in the samples. The neutron flux was monitored by a simultaneously irradiated oxygen standard.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)80957-0
|
|
|
“Systematic errors in 14-MeV neutron activation analysis for oxygen : part 1 : neutron and γ-ray attenuation effects”. Vandecasteele C, van Grieken R, Gijbels R, Speecke A, Analytica chimica acta 64, 187 (1973). http://doi.org/10.1016/S0003-2670(01)82436-3
Abstract: A detailed account is given of neutron and γ-ray attenuation effects in 14-MeV neutron activation analysis of oxygen. Appropriate neutron cross-section values have been determined in two different ways and compared with literature values. It appears that the attenuation process is best described in terms of nonelastic scattering cross-sections. It is also shown that the narrow beam total γ-ray attenuation coefficients at 6 MeV, given in the literature are suitable for correction purposes if 16N γ-rays are counted with a window of 4.56.5 MeV. Attention was paid to the contribution of β-rays when the 16N activity is counted in this energy interval with a NaI(Tl) detector.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 11
DOI: 10.1016/S0003-2670(01)82436-3
|
|
|
“Systematic errors in 14-MeV neutron activation analysis for oxygen : part 2 : a general standardization method for the determination of oxygen”. Vandecasteele C, van Grieken R, Gijbels R, Speecke A, Analytica chimica acta 65, 1 (1973). http://doi.org/10.1016/S0003-2670(01)80158-6
Abstract: A general standardization method is described for the determination of oxygen in solid samples via the 16O(n,p)16N reaction. Two systems of flux monitoring are considered: the sample versus standard comparator method and BF3 monitoring. The average flux in sample and standard, fast neutron shielding, fast neutron scattering, absorption of fast neutrons, absorption of 16N γ-rays and counting efficiency of sample and standard are considered. The influence of the target diameter on the obtained correction factors has also been studied. Total achievable accuracy is believed to be about 1%.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 12
DOI: 10.1016/S0003-2670(01)80158-6
|
|
|
“Determination of silicon in natural and pollution aerosols by 14-MeV neutron activation analysis”. Gijbels R, Dams R, Analytica chimica acta 63, 369 (1973). http://doi.org/10.1016/S0003-2670(01)82362-X
Abstract: The determination of silicon via the 28Si(n,p)28 Al reaction by means of 14-MeV neutrons is applied to the analysis of pollution and natural aerosols. A Whatman 41 filter (40 cm2) on which airborne particulate material has been collected is compressed into a 3 × 12.7 mm pellet. Standards are prepared in the same way from clean filters spiked with a silicate solution. After a 50-s irradiation and a 75-s decay time, the sample is counted for 2 min with 5 × 5 NaI(Tl) well detector. The 1.779-MeV photopeak of 28Al is measured with a single channel sealer chain or with a multichannel analyser. The reproducibility, sensitivity and liability to interference from other elements were investigated for both counting systems. The homogeneity of the pellets and the filters was checked. The overall precision of one single-channel determination was estimated to be 3.5% after a 24-h high-volume sampling time. Samples collected in urban, industrial and remote areas with concentrations ranging from 0.05 to 15 μg Si m-3 air were analysed and the results are discussed.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.513
Times cited: 16
DOI: 10.1016/S0003-2670(01)82362-X
|
|
|
“Simultaneous determination of chromium and silicon in steel by 14-mev neutron activation analysis”. Vandecasteele C, Van Grieken R, Hoste J, Analytica chimica acta 72, 31 (1974). http://doi.org/10.1016/S0003-2670(01)82945-7
Abstract: Chromium and silicon are determined simultaneously in steel by 14-MeV neutron activation analysis. The activities of 52V(Eγ=1.43 MeV,TView the MathML source=3.76 min) from 52Cr(n,p)52V and 28Al (Eγ=1.78 MeV; TView the MathML source=2.24 min) from 28Si(n,p)28Al are evaluated by mixed γ-ray spectrometry. The influence of manganese and phosphorus, the main interfering elements, is negligible for most stainless steels. The count rate should be limited, to avoid 52V pulse pile-up effects interfering in the 28Al energy region. Precisions in the 2-10% range are reached, depending on the concentrations, for a 10-min analysis time. Results for a series of steel samples are compared with industrial analyses.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)82945-7
|
|
|
“Optimization of a simple spotting procedure for x-ray fluorescence analysis of waters”. Smits J, Van Grieken R, Analytica chimica acta 88, 97 (1977). http://doi.org/10.1016/S0003-2670(01)96053-2
Abstract: Several sample preparation methods for waters for energy-dispersive x.r.f. were examined, as well as the influence of sample size on the analytical characteristics. The most satisfactory simple, rapid method proved to be spotting of 1.5 ml of water sample on a Whatman-41 cellulose filter paper provided with a wax ring of 29-mm diameter and evaporating the water with an unheated air stream from underneath. Sensitivities are below 100 p.p.b. for most elements and often below 50 p.p.b. when the optimal secondary fluorescer is used. Accuracy and precision are usually in the 1520 % range. The method is applicable to many dilute aqueous solutions as is illustrated by analysis of industrial water samples and ashed biological material.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)96053-2
|
|
|
“Reduction of trace metal levels in analytical-grade activated carbon”. Vanderborght B, Van Grieken R, Analytica chimica acta 89, 399 (1977). http://doi.org/10.1016/S0003-2670(01)84739-5
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)84739-5
|
|
|
“Comparison of preconcentration procedures for trace metals in natural waters”. Smits J, Nelissen J, Van Grieken R, Analytica chimica acta 111, 215 (1979). http://doi.org/10.1016/S0003-2670(01)93264-7
Abstract: The relative merits of eight procedures for preconcentrations of trace metal ions from natural water samples and synthetic solutions are evaluated. Spikes (100 μg l−1 ) of Mn, Co, Zn, Eu, Cs and Ba and the corresponding radioactive tracers were added to batches of drinking water, estuarine water, sea water, ground water, twice-distilled water and ahumic material solution. After equilibration for 25 months, the following techniques were applied: passage through columns of Dowex Al chelating resin and ofsilylated silica gel, filtration through laminate membrane filters and chelating diethylenetriamine cellulose filters, precipitation with sodium diethyldithiocarbamate and l-(2-pyridylazo)-2-naphthol, extraction with ammonium pyrrolidinedithiocarbamate, and chelation by 8-quinolinol (oxine) followed by adsorption on activated carbon. The quantitative characteristics of these techniques and the influence of the water matrix effects are discussed, as well as the applicability for x-ray fluorescence analysis.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)93264-7
|
|
|
“Sample contamination from a commercial grinding unit”. Van Grieken R, Van de Velde R, Robberecht H, Analytica chimica acta 118, 137 (1980). http://doi.org/10.1016/S0003-2670(01)93724-9
Abstract: The contamination of ground samples by a commercially available Lovibond McCrone Micronizing Mill is discussed. Tracer and weighing experiments showed that abrasion of corundum grinding elements was important, introducing 620 mg of abrasion products per minute of wet grinding. Agate grinding elements were abraded at ⩽6 mg min-1. The abrasion products and grinding elements were analyzed by x-ray fluorescence, spark-source mass spectrometry and neutron activation analysis. Contamination in trace element analysis of geological materials is likely to be negligible for agate grinding elements and, except for a few transition metals, also for corundum grinding elements. Contamination of typical biological samples is significant for a few elements even when agate elements are used, and is absolutely prohibitive for trace analysis when corundum elements are used.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)93724-9
|
|
|
“Enrichment of trace anions from water with 2,2'-diaminodiethylamine cellulose filters”. Smits J, Van Grieken R, Analytica chimica acta 123, 9 (1981). http://doi.org/10.1016/S0003-2670(01)83152-4
Abstract: Cellulose filters with immobilized 2,2'-diaminodiethylamine (DEN) functional groups are studied for trace anion preconcentration from aqueous solution, with subsequent x-ray fluorescence measurements. For most oxoanions with a central metal atom, nearly quantitative collection can be achieved by 10-cm2 DEN filters under the following optimized conditions: pH 36, filtration rate up to 0.5 ml cm-2 min-1, and sample volume up to 100 ml cm-2. The collection yield is independent of the trace oxoanion concentration up to at least 1.5 μmol cm-2. Although the DEN filter exhibits some selectivity towards oxoanions with a central metal atom, ionic strength affects the results; the collection efficiency is strongly depressed with salt (e.g. NaCl) concentrations above 0.01 M. The applicability of the DEN filter in anion collection is therefore limited to dilute solutions.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)83152-4
|
|
|
“Multi-element analysis of urine by energy-dispersive x-ray fluorescence spectrometry”. Vos L, Robberecht H, Van Dyck P, Van Grieken R, Analytica chimica acta 130, 167 (1981). http://doi.org/10.1016/S0003-2670(01)84161-1
Abstract: For multi-element analysis of human urine, 25-ml samples doped with yttrium as internal standard are evaporated gently and then ashed up to 460°C overnight. The residue is pelletized and analysed by energy-dispersive x-ray fluorescence. Acid addition to facilitate the digestion is not mandatory. Recoveries are nearly quantitative for traces of Fe, Ni, Cu, Zn and Sr, to a lesser extent for lead, but not for arsenic or selenium. The standard deviation per measurement is typically around 6%. The detection limits are such that some 10 elements can be determined simultaneously in normal urine, and possibly more in cases of importance to toxicology or industrial hygiene.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)84161-1
|
|
|
“Evaluation of multi-element analysis of blood serum by energy-dispersive x-ray spectrometry”. Robberecht H, Van Grieken R, Shani J, Barak S, Analytica chimica acta 136, 285 (1982). http://doi.org/10.1016/S0003-2670(01)95388-7
Abstract: Conventional energy-dispersive x-ray fluorescence is applied in the analysis of blood serum to give the concentrations of 710 elements simultaneously with minimal manipulation of the samples. Simple spotting onto a Mylar carrier of 250 μl of serum, doped with two internal standards, was chosen as the sample preparation step. Some 200 serum samples, analyzed in replicate (n = 26), were used to evaluate this procedure. The detection limits are 4 μg ml-1 for K and Ca, 0.50.2 μg ml-1 for Fe, Cu, Pb and Zn, and less than 0.1 μg ml-1 for Se, Rb and Sr. Well above these limits, the standard deviation is around 10%. Comparison with the results of other measurements on the same samples indicates an accuracy of that order. The simplicity and high throughput, and the possibility of automating the x.r.f. measurements, make the proposed procedure suitable for screening large numbers of sera.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)95388-7
|
|
|
“Preconcentration methods for the analysis of water by X-ray spectrometric techniques”. Van Grieken R, Analytica chimica acta 143, 3 (1982). http://doi.org/10.1016/S0003-2670(01)95486-8
Abstract: All published procedures for multi-element preconcentration of trace elements, prior to x-ray fluorescence analysis of water, are reviewed and critically evaluated. Most preconcentration methods applied to the determination of single elements in water are also listed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)95486-8
|
|
|
“Determination of trace selenium in biological material by preconcentration and X-ray emission spectrometry”. Robberecht H, Van Grieken R, Analytica chimica acta 147, 113 (1983). http://doi.org/10.1016/0003-2670(83)80077-4
Abstract: Selenium is determined in the ng g−1 to μg g−1 range in biological and environmental samples. A wet digestion procedure was optimized with respect to volatility losses and recovery yields, by using 75Se metabolically incorporated into rat organs. Selenium is preconcentrated from the digestion liquid by a two-step reduction with 4 M HCl and ascorbic acid. The colloidal selenium formed is adsorbed on activated carbon and filtered on a Nucleopore membrane for measurement by energy-dispersive x-ray fluorescence. Almost complete recovery was obtained, and the detection limit was 20 ng, corresponding to 10 ng g−1 for a 2-g sample. Biological reference materials were analyzed with satisfactory results, and the accuracy of the method was good.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0003-2670(83)80077-4
|
|
|
“Preparation of conducting electrodes from biological samples for multi-element trace analysis by spark-source mass spectrometry or emission spectrometry”. Vos L, Van Grieken R, Analytica chimica acta 164, 83 (1984). http://doi.org/10.1016/S0003-2670(00)85619-6
Abstract: Four decomposition procedures frequently used for biological material (dry ashing, open wet digestion, wet digestion in a teflon bomb and low-temperature ashing) are optimized for the conversion of biological samples to conducting electrodes suitable for multi-element trace determinations by spark-source mass spectrometry or emission spectrometry. The optimized procedures are evaluated with respect to contamination, retention and preconcentration of the trace elements, homogeneity of the electrodes and precision of the final results. Both dry-ashing methods are prone to losses by volatilization; simple dry ashing suffers from contamination problems during electrode preparation. Wet digestion gives better precision; digestion with nitric/sulfuric acids in an open flask is the method of choice for most elements being simpler and giving lower blanks than the bomb method.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(00)85619-6
|
|
|
“Determination of trace metals in rain water by differential-pulse stripping voltammetry”. Vos L, Komy G, Reggers G, Roekens E, Van Grieken R, Analytica chimica acta 184, 271 (1986). http://doi.org/10.1016/S0003-2670(00)86491-0
Abstract: Differential-pulse stripping voltammetry is applied to measure zinc, cadmium, lead and copper by anodic stripping and selenium(IV) by cathodic stripping in rain water at pH 2; subsequently, at pH 9,1, manganese is measured by anodic stripping on the same portion, and cobalt and nickel are measured in the adsorptive mode after formation of their dimethylglyoximates. The instrumental parameters are optimized. The linear ranges, mutual interferences and detection limits are studied. Excellent accuracy is demonstrated; the standard deviation is around 15% at 2.550 μg l−1 levels. The method is shown to be applicable for rain water.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(00)86491-0
|
|
|
“Radio-isotope neutron activation analysis for vanadium, manganese and tungsten in alloy steels”. Lins Galdino SM, Costa Dantas C, Van Grieken R, Analytica chimica acta 196, 337 (1987). http://doi.org/10.1016/S0003-2670(00)83107-4
Abstract: An instrumental neutron activation method for V, Mn and W in alloy steels with a 241 Am/Be isotopic neutron source is described. The samples were irradiated to induce the nuclear reactions 51V(n, γ) 52V, 55Mn(n, γ)56Mn, and 186W(n, γ)187W. The activities were measured with a NaI(TI) detector. Interferences on the measured photopeaks were shown to be negligible by measuring the half-lives of 62V, 56Mn and 187W.These thre elementes were determined in the range 1.512.9% in special steels; manganese in the range 0.51.6% was measured in cast irons. Calibration was done by comparison with results from wet chemistry and x-ray fluorescence spectrometry. The processing times for the vanadium, manganese and tungsten determinations were 11 min, 3 h and 26.3 h, respectively, but these were reduced greatly by intoruding a scheme wherein six samples were simultaneously irradiated and the 56Mn and 187W nuclides were measured sequentially for a series of 66 samples. The average processing time was reduced to 45 min for tungsten with a precision of 4.0% and accuracy of 3.4% and 22.8 min for manganese with a precision of 3.8% and accuracy of 3.1%.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(00)83107-4
|
|
|
“A study of the weathering of an historic building”. Leysen L, Roekens E, Komy Z, Van Grieken R, Analytica chimica acta 195, 247 (1987). http://doi.org/10.1016/S0003-2670(00)85666-4
Abstract: Various bulk and surface analytical techniques were used to study the chemical deterioration of the 13th-to-15th century limestone cathedral in Mechelen, Belgium. The weathering crust on the walls was found to be rich in sulfate, regardless of the geographic orientation. Nitrate and chloride were only detected in minor amounts in the crust and run-off samples. Attack by gaseous sulfur compounds seems to play a dominant role in the stone deterioration mechanism. Electron microprobe analysis showed predominantly bar-shaped gypsum crystals in the crust, and laser microprobe mass spectrometry showed that carbon seems to be responsible for the blackness of most crust samples. Automated electron microprobe analysis also indicated significant differences in the analytical composition of suspensions in run-off water and in rain-water.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(00)85666-4
|
|