|   | 
Details
   web
Records
Author Smits, J.; Van Grieken, R.
Title Optimization of a simple spotting procedure for x-ray fluorescence analysis of waters Type A1 Journal article
Year 1977 Publication Analytica chimica acta Abbreviated Journal
Volume (up) 88 Issue 1 Pages 97-107
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Several sample preparation methods for waters for energy-dispersive x.r.f. were examined, as well as the influence of sample size on the analytical characteristics. The most satisfactory simple, rapid method proved to be spotting of 1.5 ml of water sample on a Whatman-41 cellulose filter paper provided with a wax ring of 29-mm diameter and evaporating the water with an unheated air stream from underneath. Sensitivities are below 100 p.p.b. for most elements and often below 50 p.p.b. when the optimal secondary fluorescer is used. Accuracy and precision are usually in the 1520 % range. The method is applicable to many dilute aqueous solutions as is illustrated by analysis of industrial water samples and ashed biological material.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos A1977CQ82600011 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; 1873-4324 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116367 Serial 8337
Permanent link to this record
 

 
Author Cagno, S.; Brede, D.A.; Nuyts, G.; Vanmeert, F.; Pacureanu, A.; Tucoulou, R.; Cloetens, P.; Falkenberg, G.; Janssens, K.; Salbu, B.; Lind, O.C.
Title Combined computed nanotomography and nanoscopic x-ray fluorescence imaging of cobalt nanoparticles in caenorhabditis elegans Type A1 Journal article
Year 2017 Publication Analytical chemistry Abbreviated Journal Anal Chem
Volume (up) 89 Issue 21 Pages 11435-11442
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Synchrotron radiation phase-contrast computed nanotomography (nano-CT) and two-and three-dimensional (2D and 3D) nanoscopic X-ray fluorescence (nano-XRF) were used to investigate the internal distribution of engineered-cobalt nanoparticles (Co NPs) in exposed individuals of the nematode Caenorhabditis elegans. Whole-nematodes and selected tissues and organs were 3D-rendered: anatomical 3D renderings with 50 nm voxel size enabled the visualization of spherical nanoparticle aggregates. with size tip to 200 nm within intact C. elegans. A 20 X 37 nm(2) high-brilliance beam was employed to obtain XRF elemental distribution maps of entire nematodes or anatomical details such as embryos, which could be compared with the CT data, These maps showed Co NPs to be predominantly present within the intestine and the epithelium, and they were not colocalized with Zn granules found in the lysosonie-containing vesicles or Fe agglomerates in the intestine. Iterated XRF scanning of a specimen at 0 degrees and 90 degrees angles suggested that NP aggregates were translocated into tissues outside of the intestinal lumen. Virtual-slicing by means of 2D XRF tomography, combined with holotomography, indicated presumable presence of individual NP aggregates inside the uterus and within embryos.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000414887000041 Publication Date 2017-10-10
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2700; 5206-882x ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 6.32 Times cited 13 Open Access
Notes ; This study has been funded by the Norwegian Research Council through its Centre of Excellence (CoE) funding scheme (Project 223268/F50). We gratefully acknowledge ESRF and DESY for granting beamtime and Karl Andreas Jensen for performing ICPMS analysis. We thank Erica Maremonti for supplying the phase-contrast image used in Figure ^1A. ; Approved Most recent IF: 6.32
Call Number UA @ admin @ c:irua:147383 Serial 5520
Permanent link to this record
 

 
Author Vanderborght, B.; Van Grieken, R.
Title Reduction of trace metal levels in analytical-grade activated carbon Type A1 Journal article
Year 1977 Publication Analytica chimica acta Abbreviated Journal
Volume (up) 89 Issue 2 Pages 399-402
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos A1977DB52500022 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; 1873-4324 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116368 Serial 8466
Permanent link to this record
 

 
Author De Jong, M.; Florea, A.; de Vries, A.-M.; van Nuijs, A.L.N.; Covaci, A.; Van Durme, F.; Martins, J.C.; Samyn, N.; De Wael, K.
Title Levamisole : a common adulterant in cocaine street samples hindering electrochemical detection of cocaine Type A1 Journal article
Year 2018 Publication Analytical chemistry Abbreviated Journal Anal Chem
Volume (up) 90 Issue 8 Pages 5290-5297
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre
Abstract The present work investigates the electrochemical determination of cocaine in the presence of levamisole, one of the most common adulterants found in cocaine street samples. Levamisole misleads cocaine color tests, giving a blue color (positive test) even in the absence of cocaine. Moreover, the electrochemical detection of cocaine is also affected by the presence of levamisole, with a suppression of the oxidation signal of cocaine. When levamisole is present in the sample in ratios higher than 1:1, the cocaine signal is no longer detected, thus leading to false negative results. Mass spectrometry and nuclear magnetic resonance were used to investigate if the signal suppression is due to the formation of a complex between cocaine and levamisole in bulk solution. Strategies to eliminate this suppressing effect are further suggested in this manuscript. In a first approach, the increase of the pH of the sample solution from pH 7 to pH 12 allowed the voltammetric determination of cocaine in the presence of levamisole in a concentration range from 10 to 5000 μM at nonmodified graphite disposable electrodes with a detection limit of 5 μM. In a second approach, the graphite electrode was cathodically pretreated, resulting in the presence of oxidation peaks of both cocaine and levamisole, with a detection limit for cocaine of 3 μM over the linear range of concentrations from 10 to 2500 μM. Both these strategies have been successfully applied for the simultaneous detection of cocaine and levamisole in three street samples on unmodified graphite disposable electrodes.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000430512200049 Publication Date 2018-02-23
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2700; 5206-882x ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 6.32 Times cited 8 Open Access
Notes ; This project has received funding from the European Union's Horizon 2020 Research and Innovation Programme under the Marie Sklodowska-Curie Grant Agreement No. 753223 Narcoreader. This work was also supported by BR/314/PI/ APTADRU Project and IOF-SBO (UAntwerp). Alexander van Nuijs acknowledges the Research Foundation-Flanders (FWO) for his postdoctoral fellowship. ; Approved Most recent IF: 6.32
Call Number UA @ admin @ c:irua:149528 Serial 5693
Permanent link to this record
 

 
Author Vanmeert, F.; de Nolf, W.; De Meyer, S.; Dik, J.; Janssens, K.
Title Macroscopic X-ray powder diffraction scanning, a new method for highly selective chemical imaging of works of art : instrument optimization Type A1 Journal article
Year 2018 Publication Analytical chemistry Abbreviated Journal Anal Chem
Volume (up) 90 Issue 11 Pages 6436-6444
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract In the past decade macroscopic X-ray fluorescence imaging (MA-XRF) has become established as a method for the noninvasive investigation of flat painted surfaces, yielding large scale elemental maps. MA-XRF is limited by a lack of specificity, only allowing for indirect pigment identification based on the simultaneous presence of chemical elements. The high specificity of X-ray powder diffraction (XRPD) mapping is already being exploited at synchrotron facilities for investigations at the (sub)microscopic scale, but the technique has not yet been employed using lab sources. In this paper we present the development of a novel MA-XRPD/XRF instrument based on a laboratory X-ray source. Several combinations of X-ray sources and area detectors are evaluated in terms of their spatial and angular resolution and their sensitivity. The highly specific imaging capability of the combined MA-XRPD/XRF instrument is demonstrated on a 15th/16th century illuminated manuscript directly revealing the distribution of a large number of inorganic pigments, including the uncommon yellow pigment massicot (o-PbO). The case study illustrates the wealth of new mapping information that can be obtained in a noninvasive manner using the laboratory MA-XRPD/XRF instrument.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000434893200019 Publication Date 2018-04-06
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2700; 5206-882x ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 6.32 Times cited 11 Open Access
Notes ; The authors thank the persons involved at Incoatec GmbH, imXPAD SAS and Dectris Ltd. for loaning us some of their products over the past years. We acknowledge financial support from BELSPO (Brussels) S2-ART, the NWO (The Hague) Science4Arts “ReVisRembrandt” Project and GOA Project Solarpaint (University of Antwerp Research Council). Photo Copyright Geert Van der Snickt, 2008 for the photograph of the illuminated manuscript in the TOC graphic. ; Approved Most recent IF: 6.32
Call Number UA @ admin @ c:irua:151993 Serial 5701
Permanent link to this record
 

 
Author Vanmeert, F.; de Nolf, W.; Dik, J.; Janssens, K.
Title Macroscopic X-ray powder diffraction scanning : possibilities for quantitative and depth-selective parchment analysis Type A1 Journal article
Year 2018 Publication Analytical chemistry Abbreviated Journal Anal Chem
Volume (up) 90 Issue 11 Pages 6445-6452
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract At or below the surface of painted works of art, valuable information is present that provides insights into an objects past, such as the artists technique and the creative process that was followed or its conservation history but also on its current state of preservation. Various noninvasive techniques have been developed over the past 2 decades that can probe this information either locally (via point analysis) or on a macroscopic scale (e.g., full-field imaging and raster scanning). Recently macroscopic X-ray powder diffraction (MA-XRPD) mapping using laboratory X-ray sources was developed. This method can visualize highly specific chemical distributions at the macroscale (dm(2)). In this work we demonstrate the synergy between the quantitative aspects of powder diffraction and the noninvasive scanning capability of MA-XRPD highlighting the potential of the method to reveal new types of information. Quantitative data derived from a 15th/16th century illuminated sheet of parchment revealed three lead white pigments with different hydrocerussite-cerussite compositions in specific pictorial elements, while quantification analysis of impurities in the blue azurite pigment revealed two distinct azurite types: one rich in barite and one in quartz. Furthermore, on the same artifact, the depth-selective possibilities of the method that stem from an exploitation of the shift of the measured diffraction peaks with respect to reference data are highlighted. The influence of different experimental parameters on the depth-selective analysis results is briefly discussed. Promising stratigraphic information could be obtained, even though the analysis is hampered by not completely understood variations in the unit cell dimensions of the crystalline pigment phases.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000434893200020 Publication Date 2018-04-06
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2700; 5206-882x ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 6.32 Times cited 6 Open Access
Notes ; The authors thank Incoatec GmbH for giving us the opportunity to test the I mu S Cu X-ray source. We acknowledge financial support from BELSPO (Brussels) S2-ART, the NWO (The Hague) Science4Arts “ReVisRembrandt” project, and GOA Project Solarpaint (University of Antwerp Research Council). Photo Copyright Geert Van der Snickt, 2008 for the photograph of the illuminated manuscript in the TOC graphic. ; Approved Most recent IF: 6.32
Call Number UA @ admin @ c:irua:151994 Serial 5702
Permanent link to this record
 

 
Author De Jong, M.; Florea, A.; Eliaerts, J.; Van Durme, F.; Samyn, N.; De Wael, K.
Title Tackling poor specificity of cocaine color tests by electrochemical strategies Type A1 Journal article
Year 2018 Publication Analytical chemistry Abbreviated Journal Anal Chem
Volume (up) 90 Issue 11 Pages 6811-6819
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract This paper presents electrochemical strategies for the fast screening of cocaine and most common cutting agents found in seized drug samples. First, a study on the performance of Scott color tests on cocaine and a wide range of cutting agents is described. The cutting agents causing false positive or false negative results when in mixture with cocaine are identified. To overcome the lack of specificity of color tests, we further propose a fast screening strategy by means of square wave voltammetry on disposable graphite screen printed electrodes, which reveals the unique fingerprint of cocaine and cutting agents. By employing a forward and backward scan and by a dual pH strategy, we enrich the electrochemical fingerprint and enable the simultaneous detection of cocaine and cutting agents. The effectiveness of the developed strategies was tested for the detection of cocaine in seized cocaine samples and compared with the color tests. Moreover, we prove the usefulness of square wave voltammetry for predicting possible interfering agents in color tests, based on the reduction peak of cobalt thiocyanate. The developed electrochemical strategies allow for a quick screening of seized cocaine samples resulting in a selective identification of drugs and cutting agents.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000434893200066 Publication Date 2018-05-09
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2700; 5206-882x ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 6.32 Times cited 7 Open Access
Notes ; This project has received funding from the European Union's Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie Grant Agreement No. 753223 Narcoreader. This work was also supported by Grants BR/314 /PI/APTADRU and IOF-SBO. ; Approved Most recent IF: 6.32
Call Number UA @ admin @ c:irua:151316 Serial 5867
Permanent link to this record
 

 
Author Leysen, L.A.; Roekens, E.J.; Van Grieken, R.E.; De Geyter, G.
Title Characterization of the weathering crust of various historical buildings in Belgium Type A1 Journal article
Year 1990 Publication The science of the total environment Abbreviated Journal
Volume (up) 90 Issue Pages 117-147
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract A variety of samples, collected from different historical buildings and monuments throughout Belgium, were thoroughly studied, using several trace- and micro-analysis techniques. Thin sections of stones and mortar joints were characterized by means of electron probe X-ray microanalysis (EPXMA). The morphological appearance of the surface weathering crust and the possible presence of non-innate particles in the crust were elucidated using petrographical and electron microscopy. Quantitative characterization of the total chemical composition of the crust surface layer and underlying layer was performed by energy-dispersive X-ray fluorescence, and by ion chromatography and atomic absorption spectrometry for the leachable components. Special attention was also paid to the chemical composition of rain and air at the particular sampling sites. The element distribution in the transition zone between the weathering crust and the original stone material was found to vary greatly amongst the different samples analyzed. Detailed EPXMA measurements on pieces of the weathering crust showed remarkable differences in morphology and composition between the surface and the underlying layer, and provided information about the presence of fly-ash and soil dust particles in the crust. Except for crusts from the city of Brussels, which were all very high in sulphate, the samples appeared to contain very variable sulphate contents; very local micro-climate and environmental conditions at a particular site are more important in determining the weathering condition of the building stones than the local air pollution situation. Bulk analytical characterization further showed, in all the crust samples studied, a very small contribution of nitrogen- and chlorine-containing weathering products, in contrast to sulphur-containing weathering salts.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos A1990CJ43500010 Publication Date 2003-09-12
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0048-9697; 1879-1026 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116650 Serial 7636
Permanent link to this record
 

 
Author Verbueken, A.; Van Grieken, R.
Title Influence on photoplate evaluation parameters in spark source mass spectrometric analysis Type A1 Journal article
Year 1981 Publication Bulletin des sociétés chimiques belges Abbreviated Journal
Volume (up) 90 Issue Pages 331-341
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos Publication Date
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0037-9646 ISBN Additional Links UA library record
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116626 Serial 8099
Permanent link to this record
 

 
Author Van Borman, W.; Wouters, L.; Van Grieken, R.; Adams, F.
Title Lead particles in an urban atmosphere : an individual particle approach Type A1 Journal article
Year 1990 Publication The science of the total environment Abbreviated Journal
Volume (up) 90 Issue Pages 55-66
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract In air particulate matter, sampled at a suburban site near the city of Antwerp, Belgium, more than 1500 individual Pb-containing aerosol particles with projected diameters between 0.2 and 15 μm were analyzed by automated electron probe X-ray micro analysis (EPXMA) for 26 elements and morphological features. Laser microprobe mass analysis (LAMMA) was used to detect elements with Z < 11, particularly ammonium compounds. The Pb-containing particles were classified into five main classes: Pb-sulfates, Pb-halides, soil related Pb, Pb associated with medium atomic number elements and Pb associated with high atomic number elements. Each class was divided into several distinct particle types, of which the abundance (in number and mass %), the mean projected particle diameter, and the chemical composition were determined. Auto exhaust products are responsible for Pb-sulfates and Pb-halides, making up respectively 66.7 and 27.8% by mass of the Pb-containing particles. Ammonium sulfate coatings were found to be present on nearly all Pb particles. The observations were correlated with daily concentrations of Pb and Br, obtained by particle induced X-ray emission analysis (PIXE).
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos A1990CJ43500005 Publication Date 2003-09-12
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0048-9697; 1879-1026 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116651 Serial 8169
Permanent link to this record
 

 
Author Stranger, M.; Krata, A.; Kontozova-Deutsch, V.; Bencs, L.; Deutsch, F.; Worobiec, A.; Naveau, I.; Roekens, E.; Van Grieken, R.
Title Monitoring of NO2 in the ambient air with passive samplers before and after a road reconstruction event Type A1 Journal article
Year 2008 Publication Microchemical journal Abbreviated Journal
Volume (up) 90 Issue 2 Pages 93-98
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
Abstract Nitrogen dioxide (NO2) concentrations were used to evaluate the air quality before and after the infrastructural change of an important traffic artery in Mortsel, Antwerp (Belgium). During the reconstruction works two pairs of traffic lanes were reduced to one in each direction. Two sampling campaigns were conducted: the first one before the works in 2003 and the second one in 2005, after the road works were finished. Sampling was performed on a weekly base with the use of passive diffusion tubes on the streets, and also indoors in nearby houses. The samples were analyzed by ion chromatography, from which data the NO2 concentrations in air could be calculated. These results were compared with NO2 values from the air monitoring station 42R801 of the Flemish Environment Agency in Borgerhout, Antwerp. On the base of different NO2 concentrations, correlated well with the traffic density, sampling locations were classified into three groups as follows: 1) heavily polluted (heavy traffic); 2) moderately polluted (medium traffic); or 3) less polluted (low traffic density). Sampling sites located further from the road works, enclosed to the group less polluted, showedthe lowestNO2 concentrations. The highestNO2 levelwas found for the locations close to reconstructionworks, which belonged to the group heavily polluted. The contribution of NO2 was at the samelevel before and after the roadworks. During the first campaign it ranged from30±7 µg/m3 to 71±11 µg/m3 and during the second sampling itwas between 36±17 µg/m3 and 73±17 µg/m3. These modernizationworks had no impact on preventing the traffic-related pollutant as NO2 and as a consequence no significant effect on the air quality in the studied region. It has been proven that the impact of traffic on the air quality is unmistakably high and simply reduction of the number of the traffic lanes, intended to discourage the traffic flow, had apparently no environmentally advantageous effect
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000261084200002 Publication Date 2008-04-18
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0026-265x; 0026-265x ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:71076 Serial 8276
Permanent link to this record
 

 
Author Mihucz, V.G.; Varga, Z.; Tatár, E.; Virág, I.; Van Grieken, R.; Koleszár, Z.; Záray, G.
Title Redistribution of uranium and thorium by soil/plant interaction in a recultivated mining area Type A1 Journal article
Year 2008 Publication Microchemical journal Abbreviated Journal
Volume (up) 90 Issue 1 Pages 44-49
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract During the recultivation of the uranium mining area of Kõvágószõlõs (Hungary), the tailings were covered with clay and loess soil layers having a thickness of 30 cm and 100 cm, respectively. In the loess covering layer, acacia (Robinia pseudoacacia), poplars (Populus × albus, Populus × canescens), oak (Quercus pubescens), silver tree (Eleagnus angustifolia) were planted between 1996 and 2004. In order to establish the extent of the uranium and thorium transport from the sludge to the leaves by uptake and translocation processes through roots with a length higher than 1.3 m results in a remarkable redistribution of these pollutants, a gray poplar tree, growing spontaneously in the last uncovered tailing, being selected as reference tree. The U and Th concentrations in the leaves of the above-mentioned trees, in the covering layers as well as in the original sludge were determined by inductively coupled plasma sector field mass spectrometry (ICP-SF-MS). Generally, the Th concentration of the soils was about 4 times higher than that of uranium, while uranium concentration was about 10130 times higher than that of thorium in the leaf samples and its concentration ranged from 28 to 1045 ng g− 1, the last value belonging to the poplar tree growing on the last uncovered tailing. In order to assume the mobility and bioavailability of uranium if the dry leaves fall down, the uranium species in the leaves of the poplar tree growing in the uncovered reservoir were determined applying ultrasound-assisted extraction with distilled water and ammonium acetate as well as high performance liquid chromatographic (HPLC)-ICP-SF-MS technique. About 20% of total uranium could be extracted in form of uranyl cations and a presumably negatively charged uranium compound. Estimations revealed that the annual increment of U in the soil surface layer due to the dead fallen leaves in case of the investigated gray poplar (Populus × canescens) is about 1.2%.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000258744000008 Publication Date 2008-03-21
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0026-265x; 0026-265x ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:70717 Serial 8464
Permanent link to this record
 

 
Author Worobiec, A.; Samek, L.; Karaszkiewicz, P.; Kontozova-Deutsch, V.; Stefaniak, E.A.; van Meel, K.; Krata, A.; Bencs, L.; Van Grieken, R.
Title A seasonal study of atmospheric conditions influenced by the intensive tourist flow in the Royal Museum of Wawel Castle in Cracow, Poland Type A1 Journal article
Year 2008 Publication Microchemical journal Abbreviated Journal
Volume (up) 90 Issue 2 Pages 99-106
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
Abstract Increasingmass tourismcan generate importantmicroclimatic perturbations and also elevate indoor pollution by the transport of fine particulatematter. The purpose of this researchwas to study the indoor air conditions in the RoyalMuseum ofWawel Castle in Cracow, Poland, displaying amongst other valuable works of art also a unique collection of Flemish tapestries. The investigation involved in the determination of transport and deposition of particulate matter brought in by visitors. The microclimate inside the exhibition rooms was also monitored. Samples of suspended particulateswere collected inside and outside themuseuminwinterand summer2006.On days with intensive tourist visits the concentration of total suspended particulates was significantly higher (i.e., 130 µg/m3 inwinter and 49 µg/m3 in summer) than on those days without tourists (i.e., 73 µg/m3 and 22 µg/m3 in winter and summer, respectively). The concentrations of all investigated elementswere also considerably higher during the tourist flow. This was especially valid for soil dust associated elements (Si, K, Ca, Al, and Ti), with considerably higher levels in summer than winter. This could be linked with much more frequent tourist activity in the summer period. Also, the concentration of Clwasmuch higher inwinter than summer, due to the use of deicing salts on the roads and pavements.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000261084200003 Publication Date 2008-04-27
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0026-265x; 0026-265x ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:70988 Serial 8500
Permanent link to this record
 

 
Author Sleegers, N.; van Nuijs, A.L.N.; van den Berg, M.; De Wael, K.
Title Cephalosporin antibiotics : electrochemical fingerprints and core structure reactions investigated by LC-MSMS Type A1 Journal article
Year 2019 Publication Analytical chemistry Abbreviated Journal Anal Chem
Volume (up) 91 Issue 3 Pages 2035-2041
Keywords A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre
Abstract Electrochemistry and exploiting electrochemical fingerprints is a potent approach to address newly emerging surveillance needs, for instance for antibiotics. However, a comprehensive insight in the electrochemical oxidation behaviour and mechanism is re-quired for this sensing strategy. To address the lack in knowledge of the voltammetric behaviour of the cephalosporins antibiotics, a selection of cephalosporin antibiotics and two main intermediates were subjected to an electrochemical study of their redox behaviour by means of pulsed voltammetric techniques and small-scale electrolysis combined with HPLC-MS/MS analyses. Sur-prisingly, the detected oxidation products did not fit the earlier suggested oxidation of the sulfur group to the corresponding sul-foxide. The influence of different side chains, both at the three and the seven position of the β-lactam core structure on the elec-trochemical fingerprint were investigated. Additional oxidation signals at lower potentials were elucidated and linked to different side chains. These signals were further exploited to allow simultaneous detection of different cephalosporins in one voltammetric sweep. These fundamental insights can become the building blocks for an new on-site screening method.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000458220300055 Publication Date 2019-01-03
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2700; 5206-882x ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 6.32 Times cited 6 Open Access
Notes ; The authors acknowledge financial support from the Fund for Scientific Research (FWO) Flanders, Grant 1S 37658 17N. ; Approved Most recent IF: 6.32
Call Number UA @ admin @ c:irua:156046 Serial 5497
Permanent link to this record
 

 
Author Florea, A.; Schram, J.; De Jong, M.; Eliaerts, J.; Van Durme, F.; Kaur, B.; Samyn, N.; De Wael, K.
Title Electrochemical strategies for adulterated heroin samples Type A1 Journal article
Year 2019 Publication Analytical chemistry Abbreviated Journal Anal Chem
Volume (up) 91 Issue 12 Pages 7920-7928
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Electrochemical strategies to selectively detect heroin in street samples without the use of complicated electrode modifications were developed for the first time. For this purpose, heroin, mixing agents (adulterants, cutting agent, and impurities), and their binary mixtures were subjected to square wave voltammetry measurements at bare graphite electrodes at pH 7.0 and pH 12.0, in order to elucidate the unique electrochemical fingerprint of heroin and mixing agents as well as possible interferences or reciprocal influences. Adjusting the pH from pH 7.0 to pH 12.0 allowed a more accurate detection of heroin in the presence of most common mixing agents. Furthermore, the benefit of introducing a preconditioning step prior to running square wave voltammetry on the electrochemical fingerprint enrichment was explored. Mixtures of heroin with other drugs (cocaine, 3,4-methylenedioxymethamphetamine, and morphine) were also tested to explore the possibility of their discrimination and simultaneous detection. The feasibility of the proposed electrochemical strategies was tested on realistic heroin street samples from forensic cases, showing promising results for fast, on-site detection tools of drugs of abuse.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000472682000056 Publication Date 2019-05-30
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2700; 5206-882x ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 6.32 Times cited 2 Open Access
Notes ; This project has received funding from the European Union's Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie Grant Agreement No. 753223 Narcoreader. The authors also acknowledge IOF (UAntwerp) and Belspo for financial support. ; Approved Most recent IF: 6.32
Call Number UA @ admin @ c:irua:160061 Serial 5596
Permanent link to this record
 

 
Author Rojas, C.M.; Figueroa, L.; Janssens, K.H.; Van Espen, P.E.; Adams, F.C.; Van Grieken, R.E.
Title The elemental composition of airborne particulate matter in the Atacama desert, Chile Type A1 Journal article
Year 1990 Publication The science of the total environment Abbreviated Journal
Volume (up) 91 Issue Pages 251-267
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Air particulate samples were collected at Chapiquiña near Arica (Chile) with a six-stage cascade impactor for about 17-day periods during a 31 month interval. Sixteen elements were determined by energy dispersive X-ray fluorescence analysis, and the elemental concentrations were subjected to principal factor analysis. The variability with time of the coarse particles was described by two factors both related to soil dispersion, whereas the fine particle variations could be explained by a third factor related to marine influence. Enrichment factors were compared with those obtained in other remote continental areas, in particular those of air particulate matter sampled at Chacaltaya, Bolivia. Results point to a negligible anthropogenic influence.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos A1990CM36100019 Publication Date 2003-09-12
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0048-9697 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116652 Serial 5602
Permanent link to this record
 

 
Author Morales-Yanez, F.; Trashin, S.; Hermy, M.; Sariego, I.; Polman, K.; Muyldermans, S.; De Wael, K.
Title Fast one-step ultrasensitive detection of toxocara canis antigens by a nanobody-based electrochemical magnetosensor Type A1 Journal article
Year 2019 Publication Analytical chemistry Abbreviated Journal Anal Chem
Volume (up) 91 Issue 18 Pages 11582-11588
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Human toxocariasis (HT) is a cosmopolitan zoonotic disease caused by the migration of the larval stage of the roundworm Toxocara canis. Current HT diagnostic methods do not discriminate between active and past infections. Here, we present a method to quantify Toxocara excretory/secretory antigen, aiming to identify active cases of HT. High specificity is achieved by employing nanobodies (Nbs), single domain antigen binding fragments from camelid heavy chain-only antibodies. High sensitivity is obtained by the design of an electrochemical magnetosensor with an amperometric read-out. Reliable detection of TES antigen at 10 and 30 pg/mL level was demonstrated in phosphate buffered saline and serum, respectively. Moreover, the assay showed no cross-reactivity with other nematode antigens. To our knowledge, this is the most sensitive method to quantify the TES antigen so far. It also has great potential to develop point of care diagnostic systems in other conditions where high sensitivity and specificity are required.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000487156900016 Publication Date 2019-08-20
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2700; 5206-882x ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 6.32 Times cited 2 Open Access
Notes ; This project was funded by the Fonds Wetenschappelijk Onderzoek-Vlaanderen (FWO-Flanders, Project G.0189.13N) and BOF UAntwerp. The authors acknowledge Prof. Pierre Dorny (Institute of Tropical Medicine Antwerp) and Dr. Beatrice Nickel (Swiss Institute of Tropical Medicine) for providing the antigens needed for the cross-reactivity experiments. ; Approved Most recent IF: 6.32
Call Number UA @ admin @ c:irua:163784 Serial 5621
Permanent link to this record
 

 
Author Neven, L.; Thiruvottriyur Shanmugam, S.; Rahemi, V.; Trashin, S.; Sleegers, N.; Carrion, E.N.; Gorun, S.M.; De Wael, K.
Title Optimized photoelectrochemical detection of essential drugs bearing phenolic groups Type A1 Journal article
Year 2019 Publication Analytical chemistry Abbreviated Journal Anal Chem
Volume (up) 91 Issue 15 Pages 9962-9969
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract The World Health Organization (WHO) model “List of Essential Medicines” includes among indispensable medicines antibacterials and pain and migraine relievers. Monitoring their concentration in the environment, while challenging, is important in the context of antibiotic resistance as well as their production of highly toxic compounds via hydrolysis. Traditional detection methods such as high-performance liquid chromatography (HPLC) or LC combined with tandem mass spectrometry or UV-vis spectroscopy are time-consuming, have a high cost, require skilled operators and are difficult to adapt for field operations. In contrast, (electrochemical) sensors have elicited interest because of their rapid response, high selectivity, and sensitivity as well as potential for on-site detection. Previously, we reported a novel sensor system based on a type II photosensitizer, which combines the advantages of enzymatic sensors (high sensitivity) and photoelectrochemical sensors (easy baseline subtraction). Under red-light illumination, the photosensitizer produces singlet oxygen which oxidizes phenolic compounds present in the sample. The subsequent reduction of the oxidized phenolic compounds at the electrode surface gives rise to a quantifiable photocurrent and leads to the generation of a redox cycle. Herein we report the optimization in terms of pH and applied potential of the photoelectrochemical detection of the hydrolysis product of paracetamol, i.e., 4-aminophenol (4-AP), and two antibacterials, namely, cefadroxil (CFD, beta-lactam antibiotic) and doxycycline (DXC, tetracycline antibiotic). The optimized conditions resulted in a detection limit of 0.2 mu mol L-1 for DXC, but in a 10 times higher sensitivity, 20 nmol L-1, for CFD. An even higher sensitivity, 7 nmol L-1, was noted for 4-AP.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000480499200086 Publication Date 2019-06-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2700; 5206-882x ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 6.32 Times cited 2 Open Access
Notes ; FWO and UA-BOF are acknowledged for financial support. The Center for Functional Materials of Seton Hall University is thanked for support (S.M.G. and E.N.C.). Joren Van Loon is thanked for the graphical abstract. This research was supported by the medium scale research infrastructure funding Hercules funding (SEM). ; Approved Most recent IF: 6.32
Call Number UA @ admin @ c:irua:161831 Serial 5763
Permanent link to this record
 

 
Author Alvarez-Martin, A.; Cleland, T.P.; Kavich, G.M.; Janssens, K.; Newsome, G.A.
Title Rapid evaluation of the debromination mechanism of eosin in oil paint by direct analysis in real time and direct infusion-electrospray ionization mass spectrometry Type A1 Journal article
Year 2019 Publication Analytical chemistry Abbreviated Journal Anal Chem
Volume (up) 91 Issue 16 Pages 10856-10863
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Eosin is a synthetic organic colorant prone to fading under the influence of light. On the basis of the growing interest in the understanding of the discoloration mechanism of eosin-based lakes, this study compares the ability of two ultrafast and ultrasensitive mass spectrometry techniques to detect eosin derivatives in complex matrices, such as oil media without the use of conventional separation columns or additional sample preparation protocols. Direct analysis in real time mass spectrometry (DART-MS) and direct infusion electrospray ionization mass spectrometry (DI-ESI-MS) were used to characterize the degradation pathway of eosin in oil media. The analysis protocols developed in this study are applied to discern the degradation mechanism of the lake pigment eosin (comprising the molecule per se complexed to an inorganic substrate) dispersed in linseed oil to create an oil paint. The analysis of oil paints by high resolution MS without an extraction methodology that modifies the system chemistry allowed us to identify the degradation forms without causing any additional fragmentation. Both techniques revealed the primary photodegradation pathway of eosin in linseed oil, and DI-ESI-MS provided additional information on the native conformation of the lake.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000482545300069 Publication Date 2019-07-30
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2700; 5206-882x ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 6.32 Times cited 3 Open Access
Notes ; The authors would like to acknowledge the SolarPaint project (GOA program, Antwerp University Research Council) and Smithsonian Institution for financial support. ; Approved Most recent IF: 6.32
Call Number UA @ admin @ c:irua:162879 Serial 5800
Permanent link to this record
 

 
Author Terzano, R.; Denecke, M.A.; Falkenberg, G.; Miller, B.; Paterson, D.; Janssens, K.
Title Recent advances in analysis of trace elements in environmental samples by X-ray based techniques (IUPAC Technical Report) Type A1 Journal article
Year 2019 Publication Pure and applied chemistry Abbreviated Journal Pure Appl Chem
Volume (up) 91 Issue 6 Pages 1029-1063
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Trace elements analysis is a fundamental challenge in environmental sciences. Scientists measure trace elements in environmental media in order to assess the quality and safety of ecosystems and to quantify the burden of anthropogenic pollution. Among the available analytical techniques, X-ray based methods are particularly powerful, as they can quantify trace elements in situ. Chemical extraction is not required, as is the case for many other analytical techniques. In the last few years, the potential for X-ray techniques to be applied in the environmental sciences has dramatically increased due to developments in laboratory instruments and synchrotron radiation facilities with improved sensitivity and spatial resolution. In this report, we summarize the principles of the X-ray based analytical techniques most frequently employed to study trace elements in environmental samples. We report on the most recent developments in laboratory and synchrotron techniques, as well as advances in instrumentation, with a special attention on X-ray sources, detectors, and optics. Lastly, we inform readers on recent applications of X-ray based analysis to different environmental matrices, such as soil, sediments, waters, wastes, living organisms, geological samples, and atmospheric particulate, and we report examples of sample preparation.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000471262400011 Publication Date 2019-05-21
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0033-4545 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 2.626 Times cited 3 Open Access
Notes ; This document was developed as a part of IUPAC, Funder Id: http://dx.doi.org/ 10.13039/100006987, Project #2016-019-2-600 “Trace elements analysis of environmental samples with X-rays: from synchrotron to lab and from lab to synchrotron” led by Roberto Terzano (Task Group Chair). Task Group Members for this project were: Melissa Anne Denecke, Gerald Falkenberg, Armin Gross, Koen Janssens, Bradley Miller, David Paterson, Ryan Tappero, Fang-Jie Zhao. Their contribution to the project is gratefully acknowledged. ; Approved Most recent IF: 2.626
Call Number UA @ admin @ c:irua:161369 Serial 5803
Permanent link to this record
 

 
Author Vanmeert, F.; De Keyser, N.; van Loon, A.; Klaassen, L.; Noble, P.; Janssens, K.
Title Transmission and reflection mode macroscopic x-ray powder diffraction imaging for the noninvasive visualization of paint degradation in still life paintings by Jan Davidsz. de Heem Type A1 Journal article
Year 2019 Publication Analytical chemistry Abbreviated Journal Anal Chem
Volume (up) 91 Issue 11 Pages 7153-7161
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract The use of noninvasive chemical imaging techniques is becoming more widespread for the study of cultural heritage artifacts. Recently a mobile instrument for macroscopic X-ray powder diffraction (MA-XRPD) scanning was developed, which is capable of visualizing the distribution of crystalline (pigment) phases in quasi-flat-painted artifacts. In this study, MA-XRPD is used in both transmission and reflection mode for the analysis of three 17th century still life paintings, two paintings by Jan Davidsz. de Heem (1606-1684) and one copy painting after De Heem by an unknown artist. MA-XRPD allowed to reveal and map the presence of in situ-formed alteration products. In the works examined, two rare lead arsenate minerals, schultenite (PbHAsO4) and mimetite (Pb-5(AsO4)(3)Cl), were encountered, both at and below the paint surface; they are considered to be degradation products of the pigments realgar (alpha-As4S4) and orpiment (As2S3). In transmission mode, the depletion of lead white, present in the (second) ground layer, could be seen, illustrating the intrusive nature of this degradation process. In reflection mode, several sulfate salts, palmierite (K2Pb(SO4)(2)), syngenite (K2Ca(SO4)(2)center dot H2O), and gypsum (CaSO4 center dot 2H(2)O), could be detected, in particular, at the (top) surface of the copy painting. Estimates for the information depth and sensitivity of both transmission and reflection mode MA-XRPD for various pigments have been made. The possibility of MA-XRPD to allow for noninvasive identification and visualization of alteration products is considered a significant advantage and unique feature of this method. MA-XRPD can thus provide highly relevant information for assessing the conservation state of artworks and could guide possible future restoration treatments.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000470793800031 Publication Date 2019-05-10
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2700; 5206-882x ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 6.32 Times cited 5 Open Access
Notes ; The authors acknowledge financial support from BELSPO (Brussels) S2-ART and METOX projects, the NWO (The Hague) Science4Arts “ReVisRembrandt” project, and the GOA Project Solarpaint (University of Antwerp Research Council). The authors thank the Rijksmuseum, the Royal Museum of Fine Arts Antwerp, and their staff for the collaborations. ; Approved Most recent IF: 6.32
Call Number UA @ admin @ c:irua:160245 Serial 5882
Permanent link to this record
 

 
Author De Jong, M.; Sleegers, N.; Florea, A.; Van Loon, J.; van Nuijs, A.L.N.; Samyn, N.; De Wael, K.
Title Unraveling the mechanisms behind the complete suppression of cocaine electrochemical signals by chlorpromazine, promethazine, procaine, and dextromethorphan Type A1 Journal article
Year 2019 Publication Analytical chemistry Abbreviated Journal Anal Chem
Volume (up) 91 Issue 24 Pages 15453-15460
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre; Product development
Abstract The present work investigates the challenges accompanied by the electrochemical cocaine detection in physiological conditions (pH 7) in the presence of chlorpromazine, promethazine, procaine, and dextromethorphan, frequently used cutting agents in cocaine street samples. The problem translates into the absence of the cocaine oxidation signal (signal suppression) when in a mixture with one of these compounds, leading to false negative results. Although a solution to this problem was provided through earlier experiments of our group, the mechanisms behind the suppression are now fundamentally investigated via electrochemical and liquid chromatography quadrupole-time-of-flight mass spectrometry (LC-QTOF-MS) strategies. The latter was used to confirm the passivation of the electrodes due to their interaction with promethazine and chlorpromazine. Electron transfer mechanisms were further identified via linear sweep voltammetry. Next, adsorption experiments were performed on the graphite screen printed electrodes both with and without potential assistance in order to confirm if the suppression of the cocaine signals is due to passivation induced by the cutting agents or their oxidized products. The proposed strategies allowed us to identify the mechanisms of cocaine suppression for each cutting agent mentioned. Suppression due to procaine and dextromethorphan is caused by fouling of the electrode surface by their oxidized forms, while for chlorpromazine and promethazine the suppression of the cocaine signal is related to the strong adsorption of these (nonoxidized) cutting agents onto the graphite electrode surface. These findings provide fundamental insights in possible suppression and other interfering mechanisms using electrochemistry in general not only in the drug detection sector.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000503910600018 Publication Date 2019-11-14
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2700; 5206-882x ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 6.32 Times cited Open Access
Notes ; The authors acknowledge financial support from IOF-SBO/POC (UAntwerp) and the Fund for Scientific Research (FWO) Flanders, Grant 1S 37658 17N. ; Approved Most recent IF: 6.32
Call Number UA @ admin @ c:irua:165727 Serial 5887
Permanent link to this record
 

 
Author de Maeyer-Worobiec, A.; Dekov, V.M.; Laane, R.W.P.M.; Van Grieken, R.
Title EPXMA survey of shelf sediments (Southern Bight, North Sea): a glance beyond the XRD-invisible Type A1 Journal article
Year 2009 Publication Microchemical journal Abbreviated Journal
Volume (up) 91 Issue 1 Pages 21-31
Keywords A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Shelf sediments of the southern North Sea, were studied with a microanalytical [electron probe X-ray microanalysis (EPXMA)] and two bulk [X-ray diffraction (XRD) and X-ray fluorescence (XRF)] techniques. The investigation proved that the promptness of the microanalytical method is combined with a reasonable analytical reliability. XRD studies of such a type of sediments with monotonous mineral composition are not able to provide mineralogical information beyond the main well-crystalline minerals and the mineralogical quantitative characteristic of the sediment based on XRD estimations are incorrect. The EPXMA mineralogical interpretations are based on the statistical evaluation of a huge data set (thousands of mineral particles) and provide a rather correct quantitative determination of the main minerals. The comparative EPXMAXRF study revealed that the Al, Si, K, Ca, Fe and to some extent Ti contents estimated by EPXMA are fairly reliable. In this respect the accuracy of the EPXMA-based mineral identification of the pure silicates, pure aluminosilicates, and Al-, Ca-, Fe- and Ti-containing minerals with simple composition is very high. Mg-calcite, augite and apatite determinations are assessed to be correct. The supposed accuracy of the clay mineral determinations is slightly lower (7080%) than that of the other main minerals due to the complex and varying composition of the clays. The identification of XRD-invisible accessory minerals and quantification of their presence in the sediments is an essential advantage of the EPXMA, which makes it a useful approach in tracing the origin of the sediments, the pathways of their transport and the geochemical processes they have undergone. However, the EPXMA has several flaws, which need to be solved in the future sediment investigations: (1) calibration with natural standards is needed in order to provide a higher accuracy of the mineral determinations; (2) any EPXMA study of sediments needs to be secured with XRF examinations of selected samples since EPXMA gives only semi-quantitative information about the abundance of the elements; (3) ultra-thin window EPXMA of low-Z elements has to be used since some of them (O, C) are always present in the main sediment components: silicates, aluminosilicates, carbonates and metal oxyhydroxides; (4) the interpretations of the clay fraction have to be supported with detailed XRD investigations of selected samples, while the mineralogy of the silt and sand fractions needs to be backed up with optical microscopy studies. The information from different analytical techniques (EPXMA with XRFXRD-optical microscopy of selected samples) combined with the knowledge about the most possible minerals in a given environment, would give the most reliable results in studying mineralogical composition of shelf sediments.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000262963300006 Publication Date 2008-07-14
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0026-265x; 0026-265x ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:71604 Serial 7933
Permanent link to this record
 

 
Author Godoi, R.H.M.; Aerts, K.; Harlay, J.; Kaegi, R.; Ro, C.-U.; Chou, L.; Van Grieken, R.
Title Organic surface coating on Coccolithophores – Emiliania huxleyi: its determination and implication in the marine carbon cycle Type A1 Journal article
Year 2009 Publication Microchemical journal Abbreviated Journal
Volume (up) 91 Issue 2 Pages 266-271
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Most of the marine precipitation of CaCO3 is due to the biological activities of planktonic and benthic organisms in waters largely oversaturated with respect to calcium carbonates. This saturation state is expected to decrease as CO2 increases in seawater. A conventional view in oceanography suggests that calcium carbonates organisms are preserved in oversaturated waters and dissolve only below the lysocline. However, it has be postulated that a fraction of the CaCO3 precipitated biogenically could dissolve in oversaturated waters due to the formation of microenvironments in which respired CO2 decreases the saturation state of seawater (Ù) in the vicinity of CaCO3 crystals. In the present study, cells of the coccolithophore Emiliania huxleyi obtained from laboratory cultures and field samples collected in the Gulf of Biscay, were examined using variable-energy electron-probe microanalysis, to determine the presence and thickness of their organic coating. In addition, a new approach for transferring micrometer-sized particles from a filter onto transmission electron microscope grids using manipulators was used to investigate individual coccolithophores. The dry thickness of an organic coating over the coccolithophore surface was found to range between 280 and 350 nm. The resemblance of this coating to the carbohydrates produced and released by the cell is discussed as well as their potential for constituting a microenvironment that hosts bacteria. The properties of this organic coating and its role in the preservation/dissolution and export of biogenic carbonates in the water column are one of the major issues of carbonate geochemistry.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000264238000020 Publication Date 2009-01-02
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0026-265x; 0026-265x ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:73322 Serial 8346
Permanent link to this record
 

 
Author van der Snickt, G.; de Nolf, W.; Vekemans, B.; Janssens, K.
Title μ-XRF/μ-RS vs. SR μ-XRD for pigment identification in illuminated manuscripts Type A1 Journal article
Year 2008 Publication Applied physics A : materials science & processing Abbreviated Journal Appl Phys A-Mater
Volume (up) 92 Issue 1 Pages 59-68
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract For the non-destructive identification of pigments and colorants in works of art, in archaeological and in forensic materials, a wide range of analytical techniques can be used. Bearing in mind that every method holds particular limitations, two complementary spectroscopic techniques, namely confocal ì-Raman spectroscopy (ì-RS) and ì-X-ray fluorescence spectroscopy (ì-XRF), were joined in one instrument. The combined ì-XRF and ì-RS device, called PRAXIS unites both complementary techniques in one mobile setup, which allows ì- and in situ analysis. ì-XRF allows one to collect elemental and spatially-resolved information in a non-destructive way on major and minor constituents of a variety of materials. However, the main disadvantages of ì-XRF are the penetration depth of the X-rays and the fact that only elements and not specific molecular combinations of elements can be detected. As a result ì-XRF is often not specific enough to identify the pigments within complex mixtures. Confocal Raman microscopy (ì-RS) can offer a surplus as molecular information can be obtained from single pigment grains. However, in some cases the presence of a strong fluorescence background limits the applicability. In this paper, the concrete analytical possibilities of the combined PRAXIS device are evaluated by comparing the results on an illuminated sheet of parchment with the analytical information supplied by synchrotron radiation ì-X-ray diffraction (SR ì-XRD), a highly specific technique.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000256426000008 Publication Date 2008-03-19
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0947-8396 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 1.455 Times cited 56 Open Access
Notes Approved Most recent IF: 1.455; 2008 IF: 1.884
Call Number UA @ admin @ c:irua:74465 Serial 5695
Permanent link to this record
 

 
Author Schram, J.; Parrilla, M.; Sleegers, N.; Samyn, N.; Bijvoets, S.M.; Heerschop, M.W.J.; van Nuijs, A.L.N.; De Wael, K.
Title Identifying Electrochemical Fingerprints of Ketamine with Voltammetry and Liquid Chromatography–Mass Spectrometry for Its Detection in Seized Samples Type A1 Journal article
Year 2020 Publication Analytical Chemistry Abbreviated Journal Anal Chem
Volume (up) 92 Issue 19 Pages 13485-13492
Keywords A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre
Abstract Herein, a straightforward electrochemical approach for the determination of ketamine in street samples and seizures is presented by employing screen-printed electrodes (SPE). Square wave voltammetry (SWV) is used to study the electrochemical behavior of the illicit drug, thus profiling the different oxidation states of the substance at different pHs. Besides, the oxidation pathway of ketamine on SPE is investigated for the first time with liquid chromatography–high-resolution mass spectrometry. Under the optimized conditions, the calibration curve of ketamine at buffer solution (pH 12) exhibits a sensitivity of 8.2 μA μM–1, a linear relationship between 50 and 2500 μM with excellent reproducibility (RSD = 2.2%, at 500 μM, n = 7), and a limit of detection (LOD) of 11.7 μM. Subsequently, binary mixtures of ketamine with adulterants and illicit drugs are analyzed with SWV to investigate the electrochemical fingerprint. Moreover, the profile overlapping between different substances is addressed by the introduction of an electrode pretreatment and the integration of a tailor-made script for data treatment. Finally, the approach is tested on street samples from forensic seizures. Overall, this system allows for the on-site identification of ketamine by law enforcement agents in an easy-to-use and rapid manner on cargos and seizures, thereby disrupting the distribution channel and avoiding the illicit drug reaching the end-user.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000580426800091 Publication Date 2020-10-06
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2700 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 7.4 Times cited Open Access
Notes Universiteit Antwerpen; H2020 Societal Challenges, 833787 ; Fonds Wetenschappelijk Onderzoek, 1S3765817N 1SB8120N ; Approved Most recent IF: 7.4; 2020 IF: 6.32
Call Number AXES @ axes @c:irua:170523 Serial 6435
Permanent link to this record
 

 
Author Monico, L.; Cotte, M.; Vanmeert, F.; Amidani, L.; Janssens, K.; Nuyts, G.; Garrevoet, J.; Falkenberg, G.; Glatzel, P.; Romani, A.; Miliani, C.
Title Damages induced by synchrotron radiation-based X-ray microanalysis in chrome yellow paints and related Cr-compounds : assessment, quantification, and mitigation strategies Type A1 Journal article
Year 2020 Publication Analytical Chemistry Abbreviated Journal Anal Chem
Volume (up) 92 Issue 20 Pages 14164-14173
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Synchrotron radiation (SR)-based X-ray methods are powerful analytical tools for several purposes. They are widely used to probe the degradation mechanisms of inorganic artists' pigments in paintings, including chrome yellows (PbCr1-xSxO4; 0 <= x <= 0.8), a class of compounds often found in Van Gogh masterpieces. However, the high intensity and brightness of SR beams raise important issues regarding the potential damage inflicted on the analyzed samples. A thorough knowledge of the SR X-ray sensitivity of each class of pigment in the painting matrix is therefore required to find analytical strategies that seek to minimize the damage for preserving the integrity of the analyzed samples and to avoid data misinterpretation. Here, we employ a combination of Cr K-edge X-ray absorption near-edge structure spectroscopy, Cr-K-beta X-ray emission spectroscopy, and X-ray diffraction to monitor and quantify the effects of SR X-rays on the stability of chrome yellows and related Cr compounds and to define mitigation strategies. We found that the SR X-ray beam exposure induces changes in the oxidation state and local coordination environment of Cr ions and leads to a loss of the compound's crystalline structure. The extent of X-ray damage depends on some intrinsic properties of the samples (chemical composition of the pigment and the presence/absence and nature of the binder). It can be minimized by optimizing the overall fluence/dose released to the samples and by working in vacuum and under cryogenic conditions.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000584418100072 Publication Date 2020-09-21
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2700; 5206-882x ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 7.4 Times cited Open Access
Notes Approved Most recent IF: 7.4; 2020 IF: 6.32
Call Number UA @ admin @ c:irua:174363 Serial 7754
Permanent link to this record
 

 
Author Wiorek, A.; Parrilla, M.; Cuartero, M.; Crespo, G.A.
Title Epidermal patch with glucose biosensor : pH and temperature correction toward more accurate sweat analysis during sport practice Type A1 Journal article
Year 2020 Publication Analytical Chemistry Abbreviated Journal Anal Chem
Volume (up) 92 Issue 14 Pages 10153-10161
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract We present an epidermal patch for glucose analysis in sweat incorporating for the first time pH and temperature correction according to local dynamic fluctuations in sweat during on-body tests. This sort of correction is indeed the main novelty of the paper, being crucial toward reliable measurements in every sensor based on an enzymatic element whose activity strongly depends on pH and temperature. The results herein reported for corrected glucose detection during on-body measurements are supported by a two-step validation protocol: with the biosensor operating off- and on-bodily, correlating the results with UV-vis spectrometry and/or ion chromatography. Importantly, the wearable device is a flexible skin patch that comprises a microfluidic cell designed with a sweat collection zone coupled to a fluidic channel in where the needed electrodes are placed: glucose biosensor, pH potentiometric electrode and a temperature sensor. The glucose biosensor presents a linear range of response within the expected physiological levels of glucose in sweat (10-200 mu M), and the calibration parameters are dynamically adjusted to any change in pH and temperature during the sport practice by means of a new “correction approach”. In addition, the sensor displays a fast response time, appropriate selectivity, and excellent reversibility. A total of 9 validated on-body tests are presented: the outcomes revealed a great potential of the wearable glucose sensor toward the provision of reliable physiological data linked to individuals during sport activity. In particular, the developed “correction approach” is expected to impact into the next generation of wearable devices that digitalize physiological activities through chemical information in a trustable manner for both sport and healthcare applications.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000554986200089 Publication Date 2020-06-26
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2700; 5206-882x ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 7.4 Times cited Open Access
Notes Approved Most recent IF: 7.4; 2020 IF: 6.32
Call Number UA @ admin @ c:irua:175265 Serial 7931
Permanent link to this record
 

 
Author Newsome, G.A.; Kavich, G.; Alvarez-Martin, A.
Title Interface for reproducible, multishot direct analysis of solid-phase microextraction samples Type A1 Journal article
Year 2020 Publication Analytical Chemistry Abbreviated Journal Anal Chem
Volume (up) 92 Issue 6 Pages 4182-4186
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract An enclosed interface that joins a direct analysis in real time (DART) probe, solid-phase microextraction (SPME) fiber, and the inlet of a high-resolution mass spectrometer is described. Unlike other systems to couple SPME sampling to ambient mass spectrometry, the interface is able to perform discrete analyses on different areas of a single SPME fiber device for up to three technical replicate measurements of one sampling event. Inlet flow speed and desorption temperature are optimized, and reproducibility is demonstrated between replicate analyses on the same derivatized SPME fiber and with sequential fiber sampling events, yielding analyte measurement center of variance (CV) from 3 to 6%. Conditioning is also performed with the enclosed DART. The interface is a straightforward addition to commercially available technologies, and machine diagrams for custom components operated with SPME/DART/MS equipment are included.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000526563900004 Publication Date 2020-02-07
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2700; 5206-882x ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 7.4 Times cited Open Access
Notes Approved Most recent IF: 7.4; 2020 IF: 6.32
Call Number UA @ admin @ c:irua:181926 Serial 8113
Permanent link to this record
 

 
Author Liu, Y.; Cánovas, R.; Crespo, G.A.; Cuartero, M.
Title Thin-layer potentiometry for creatinine detection in undiluted human urine using ion-exchange membranes as barriers for charged interferences Type A1 Journal article
Year 2020 Publication Analytical Chemistry Abbreviated Journal Anal Chem
Volume (up) 92 Issue 4 Pages 3315-3323
Keywords A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Herein, thin-layer potentiometry combined with ion-exchange membranes as barriers for charged interferences is demonstrated for the analytical detection of creatinine (CRE) in undiluted human urine. Briefly, CRE diffuses through an anion-exchange membrane (AEM) from a sample contained in one fluidic compartment to a second reservoir, containing the enzyme CRE deiminase. There, CRE reacts with the enzyme, and the formation of ammonium is dynamically monitored by potentiometric ammonium-selective electrodes. This analytical concept is integrated into a lab-on-a-chip microfluidic cell that allows for a high sample throughput and the operation under stop-flow mode, which allows CRE to passively diffuse across the AEM. Conveniently, positively charged species (i.e., potassium, sodium, and ammonium, among others) are repelled by the AEM and never reach the ammonium-selective electrodes; thus, possible interference in the response can be avoided. As a result, the dynamic potential response of the electrodes is entirely ascribed to the stoichiometric formation of ammonium. The new CRE biosensor exhibits a Nernstian slope, within a linear range of response from 1 to 50 mM CRE concentration. As expected, the response time (15–60 min) primarily depends on the CRE diffusion across the AEM. CRE analysis in urine samples displayed excellent results, without requiring sample pretreatment (before the introduction of the sample in the microfluidic chip) and with high compatibility with development into a potential point-of-care clinical tool. In an attempt to decrease the analysis time, the presented analytical methodology for CRE detection is translated into an all-solid-state platform, in which the enzyme is immobilized on the surface of the ammonium-selective electrode and with the AEM on top. While more work is necessary in this direction, the CRE sensor appears to be promising for CRE analysis in both urine and blood.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos Publication Date 2020-01-23
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2700; 5206-882x ISBN Additional Links UA library record
Impact Factor 7.4 Times cited Open Access
Notes Approved Most recent IF: 7.4; 2020 IF: 6.32
Call Number UA @ admin @ c:irua:184380 Serial 8667
Permanent link to this record