|
Records |
Links |
|
Author |
Oleshko, V.P.; Gijbels, R.H.; Jacob, W.A. |
|
|
Title |
Analytical electron microscopy of silver halide photographic systems |
Type |
A1 Journal article |
|
Year |
2000 |
Publication |
Micron |
Abbreviated Journal |
Micron |
|
|
Volume |
31 |
Issue |
|
Pages |
55-95 |
|
|
Keywords |
A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000083352100007 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0968-4328; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.98 |
Times cited |
8 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 1.98; 2000 IF: 1.324 |
|
|
Call Number |
UA @ lucian @ c:irua:34068 |
Serial |
108 |
|
Permanent link to this record |
|
|
|
|
Author |
van Dyck, D.; Lobato, I.; Chen, F.-R.; Kisielowski, C. |
|
|
Title |
Do you believe that atoms stay in place when you observe them in HREM? |
Type |
A1 Journal article |
|
Year |
2015 |
Publication |
Micron |
Abbreviated Journal |
Micron |
|
|
Volume |
68 |
Issue |
68 |
Pages |
158-163 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
Recent advancements in aberration-corrected electron microscopy allow for an evaluation of unexpectedly large atom displacements beyond a resolution limit of similar to 0.5 angstrom, which are found to be dose-rate dependent in high resolution images. In this paper we outline a consistent description of the electron scattering process, which explains these unexpected phenomena. Our approach links thermal diffuse scattering to electron beam-induced object excitation and relaxation processes, which strongly contribute to the image formation process. The effect can provide an explanation for the well-known contrast mismatch (“Stobbs factor”) between image calculations and experiments. (C) 2014 Elsevier Ltd. All rights reserved. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Oxford |
Editor |
|
|
|
Language |
|
Wos |
000348016500023 |
Publication Date |
2014-09-16 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0968-4328; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.98 |
Times cited |
11 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 1.98; 2015 IF: 1.988 |
|
|
Call Number |
c:irua:123802 |
Serial |
745 |
|
Permanent link to this record |
|
|
|
|
Author |
Kirilenko, D.A.; Dideykin, A.T.; Aleksenskiy, A.E.; Sitnikova, A.A.; Konnikov, S.G.; Vul', A.Y. |
|
|
Title |
One-step synthesis of a suspended ultrathin graphene oxide film: Application in transmission electron microscopy |
Type |
A1 Journal article |
|
Year |
2015 |
Publication |
Micron |
Abbreviated Journal |
Micron |
|
|
Volume |
68 |
Issue |
68 |
Pages |
23-26 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
Ultrathin graphene films find their use as advantageous support for nano- and biomaterials investigations. Thin film causes a very slight deterioration to measured signals, thus providing more details of the object's structure at nanoscale. The ultimate thinness of graphene works in the best way for this purpose. However, obtaining suspended thin film of a large-area, which is convenient for applications, is often a relatively complicated and time-consuming task. Here we present a one-step 1-min technique for synthesis of an extremely thin (about 1-2 nm) continuous film suspended over cells of a conventional copper grid (50-400 mu m mesh). This technique enables us to acquire a large-area film which is water-resistant, stable in organic solvents and can act as a support when studying nanoparticles or biomaterials. Moreover, the very mechanism of the film formation can be interesting from the point of view of other applications of ultrathin graphene oxide papers. (C) 2014 Elsevier Ltd. All rights reserved. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Oxford |
Editor |
|
|
|
Language |
|
Wos |
000348016500004 |
Publication Date |
2014-08-30 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0968-4328; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.98 |
Times cited |
13 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 1.98; 2015 IF: 1.988 |
|
|
Call Number |
c:irua:123800 |
Serial |
2467 |
|
Permanent link to this record |
|
|
|
|
Author |
Xu, Q.; Zandbergen, H.W.; van Dyck, D. |
|
|
Title |
Imaging from atomic structure to electronic structure |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
Micron |
Abbreviated Journal |
Micron |
|
|
Volume |
43 |
Issue |
4 |
Pages |
524-531 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
This paper discusses the possibility of retrieving the electron distribution (with highlighted valence electron distribution information) of materials from recorded HREM images. This process can be achieved by solving two inverse problems: reconstruction of the exit wave and reconstruction of the electron distribution from exit waves. The first inverse problem can be solved using a focal series reconstruction method. We show that the second inverse problem can be solved by combining a series of exit waves recorded at different thickness conditions. This process is designed based on an improved understanding of the dynamical scattering process. It also explains the fundamental difficulty of obtaining the valence electron distribution information and the basis of our solution. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Oxford |
Editor |
|
|
|
Language |
|
Wos |
000301702400005 |
Publication Date |
2011-11-05 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0968-4328; |
ISBN |
|
Additional Links |
UA library record; WoS full record |
|
|
Impact Factor |
1.98 |
Times cited |
|
Open Access |
|
|
|
Notes |
Fwo |
Approved |
Most recent IF: 1.98; 2012 IF: 1.876 |
|
|
Call Number |
UA @ lucian @ c:irua:93634 |
Serial |
1553 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Aert, S.; van den Broek, W.; Goos, P.; van Dyck, D. |
|
|
Title |
Model-based electron microscopy : from images toward precise numbers for unknown structure parameters |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
Micron |
Abbreviated Journal |
Micron |
|
|
Volume |
43 |
Issue |
4 |
Pages |
509-515 |
|
|
Keywords |
A1 Journal article; Engineering Management (ENM); Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
Statistical parameter estimation theory is proposed as a method to quantify electron microscopy images. It aims at obtaining precise and accurate values for the unknown structure parameters including, for example, atomic column positions and types. In this theory, observations are purely considered as data planes, from which structure parameters have to be determined using a parametric model describing the images. The method enables us to measure positions of atomic columns with a precision of the order of a few picometers even though the resolution of the electron microscope is one or two orders of magnitude larger. Moreover, small differences in averaged atomic number, which cannot be distinguished visually, can be quantified using high-angle annular dark field scanning transmission electron microscopy images. Finally, it is shown how to optimize the experimental design so as to attain the highest precision. As an example, the optimization of the probe size for nanoparticle radius measurements is considered. It is also shown how to quantitatively balance signal-to-noise ratio and resolution by adjusting the probe size. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Oxford |
Editor |
|
|
|
Language |
|
Wos |
000301702400003 |
Publication Date |
2011-11-03 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0968-4328; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.98 |
Times cited |
7 |
Open Access |
|
|
|
Notes |
Fwo |
Approved |
Most recent IF: 1.98; 2012 IF: 1.876 |
|
|
Call Number |
UA @ lucian @ c:irua:94114 |
Serial |
2099 |
|
Permanent link to this record |
|
|
|
|
Author |
Leroux, O.; Leroux, F.; Bagniewska-Zadworna,.; Knox, J.P.; Claeys, M.; Bals, S.; Viane, R.L.L. |
|
|
Title |
Ultrastructure and composition of cell wall appositions in the roots of Asplenium (Polypodiales) |
Type |
A1 Journal article |
|
Year |
2011 |
Publication |
Micron |
Abbreviated Journal |
Micron |
|
|
Volume |
42 |
Issue |
8 |
Pages |
863-870 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
Cell wall appositions (CWAs), formed by the deposition of extra wall material at the contact site with microbial organisms, are an integral part of the response of plants to microbial challenge. Detailed histological studies of CWAs in fern roots do not exist. Using light and electron microscopy we examined the (ultra)structure of CWAs in the outer layers of roots of Asplenium species. All cell walls studded with CWAs were impregnated with yellow-brown pigments. CWAs had different shapes, ranging from warts to elongated branched structures, as observed with scanning and transmission electron microscopy. Ultrastructural study further showed that infecting fungi grow intramurally and that they are immobilized by CWAs when attempting to penetrate intracellularly. Immunolabelling experiments using monoclonal antibodies indicated pectic homogalacturonan, xyloglucan, mannan and cellulose in the CWAs, but tests for lignins and callose were negative. We conclude that these appositions are defense-related structures made of a non-lignified polysaccharide matrix on which phenolic compounds are deposited in order to create a barrier protecting the root against infections. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Oxford |
Editor |
|
|
|
Language |
|
Wos |
000294942600013 |
Publication Date |
2011-06-24 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0968-4328; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.98 |
Times cited |
20 |
Open Access |
|
|
|
Notes |
Fwo |
Approved |
Most recent IF: 1.98; 2011 IF: 1.527 |
|
|
Call Number |
UA @ lucian @ c:irua:92540 |
Serial |
3798 |
|
Permanent link to this record |
|
|
|
|
Author |
Felten, A.; Ghijsen, J.; Pireaux, J.-J.; Drube, W.; Johnson, R.L.; Liang, D.; Hecq, M.; Van Tendeloo, G.; Bittencourt, C. |
|
|
Title |
Electronic structure of Pd nanoparticles on carbon nanotubes |
Type |
A1 Journal article |
|
Year |
2009 |
Publication |
Micron |
Abbreviated Journal |
Micron |
|
|
Volume |
40 |
Issue |
1 |
Pages |
74-79 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
The effect of the oxygen plasma treatment on the electronic states of multi-wall carbon nanotubes (MWCNTs) is analyzed by X-ray photoemission measurements (XPS) and UPS, both using synchrotron radiation. It is found that the plasma treatment effectively grafts oxygen at the CNT-surface. Thereafter, the interaction between evaporated Pd and pristine or oxygen plasma-treated MWCNTs is investigated. Pd is found to nucleate at defective sites, whether initially present or introduced by oxygen plasma treatment. The plasma treatment induced a uniform dispersion of Pd clusters at the CNT-surface. The absence of additional features in the Pd 3d and C I s core levels spectra testifies that no Pd-C bond is formed. The shift of the Pd 3d core level towards high-binding energy for the smallest clusters is attributed to the Coulomb energy of the charged final state. (C) 2008 Elsevier Ltd. All rights reserved. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Oxford |
Editor |
|
|
|
Language |
|
Wos |
000261420900015 |
Publication Date |
2008-02-21 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0968-4328; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.98 |
Times cited |
44 |
Open Access |
|
|
|
Notes |
Pai 608 |
Approved |
Most recent IF: 1.98; 2009 IF: 1.626 |
|
|
Call Number |
UA @ lucian @ c:irua:94578 |
Serial |
1015 |
|
Permanent link to this record |
|
|
|
|
Author |
Ruelle, B.; Felten, A.; Ghijsen, J.; Drube, W.; Johnson, R.L.; Liang, D.; Erni, R.; Van Tendeloo, G.; Sophie, P.; Dubois, P.; Godfroid, T.; Hecq, M.; Bittencourt, C.; |
|
|
Title |
Functionalization of MWCNTs with atomic nitrogen |
Type |
A1 Journal article |
|
Year |
2009 |
Publication |
Micron |
Abbreviated Journal |
Micron |
|
|
Volume |
40 |
Issue |
1 |
Pages |
85-88 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
In this study of the changes induced by exposing MWCNTs to a nitrogen plasma, it was found by HRTEM that the atomic nitrogen exposure does not significantly etch the surface of the carbon nanotube (CNT). Nevertheless, the atomic nitrogen generated by a microwave plasma effectively grafts amine, nitrile, amide, and oxime groups onto the CNT surface, as observed by XPS, altering the density of valence electronic states, as seen in UPS. (C) 2008 Elsevier Ltd. All fights reserved. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Oxford |
Editor |
|
|
|
Language |
|
Wos |
000261420900017 |
Publication Date |
2008-01-29 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0968-4328; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.98 |
Times cited |
24 |
Open Access |
|
|
|
Notes |
Pai 6/1; Pa 6/27 |
Approved |
Most recent IF: 1.98; 2009 IF: 1.626 |
|
|
Call Number |
UA @ lucian @ c:irua:103080 |
Serial |
1305 |
|
Permanent link to this record |
|
|
|
|
Author |
Bertoni, G.; Calmels, L. |
|
|
Title |
First-principles calculation of the electronic structure and energy loss near edge spectra of chiral carbon nanotubes |
Type |
A1 Journal article |
|
Year |
2006 |
Publication |
Micron |
Abbreviated Journal |
Micron |
|
|
Volume |
37 |
Issue |
5 |
Pages |
486-491 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000238806400018 |
Publication Date |
2005-11-22 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0968-4328; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.98 |
Times cited |
12 |
Open Access |
|
|
|
Notes |
Fwo |
Approved |
Most recent IF: 1.98; 2006 IF: 1.200 |
|
|
Call Number |
UA @ lucian @ c:irua:59604 |
Serial |
1200 |
|
Permanent link to this record |
|
|
|
|
Author |
Yang, Z.; Schryvers, D. |
|
|
Title |
Study of changes in composition and EELS ionization edges upon Ni4Ti3 precipitation in a NiTi alloy |
Type |
A1 Journal article |
|
Year |
2006 |
Publication |
Micron |
Abbreviated Journal |
Micron |
|
|
Volume |
37 |
Issue |
5 |
Pages |
503-507 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000238806400020 |
Publication Date |
2005-09-08 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0968-4328; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.98 |
Times cited |
10 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 1.98; 2006 IF: 1.200 |
|
|
Call Number |
UA @ lucian @ c:irua:59605 |
Serial |
3327 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Aert, S.; den Dekker, A.J.; van Dyck, D. |
|
|
Title |
How to optimize the experimental design of quantitative atomic resolution TEM experiments? |
Type |
A1 Journal article |
|
Year |
2004 |
Publication |
Micron |
Abbreviated Journal |
Micron |
|
|
Volume |
35 |
Issue |
|
Pages |
425-429 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000221721000005 |
Publication Date |
2004-03-06 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0968-4328; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.98 |
Times cited |
14 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 1.98; 2004 IF: 1.464 |
|
|
Call Number |
UA @ lucian @ c:irua:47514 |
Serial |
1495 |
|
Permanent link to this record |
|
|
|
|
Author |
Martinez, G.T.; de Backer, A.; Rosenauer, A.; Verbeeck, J.; Van Aert, S. |
|
|
Title |
The effect of probe inaccuracies on the quantitative model-based analysis of high angle annular dark field scanning transmission electron microscopy images |
Type |
A1 Journal article |
|
Year |
2014 |
Publication |
Micron |
Abbreviated Journal |
Micron |
|
|
Volume |
63 |
Issue |
|
Pages |
57-63 |
|
|
Keywords |
A1 Journal article; Engineering Management (ENM); Electron microscopy for materials research (EMAT) |
|
|
Abstract |
Quantitative structural and chemical information can be obtained from high angle annular dark field scanning transmission electron microscopy (HAADF STEM) images when using statistical parameter estimation theory. In this approach, we assume an empirical parameterized imaging model for which the total scattered intensities of the atomic columns are estimated. These intensities can be related to the material structure or composition. Since the experimental probe profile is assumed to be known in the description of the imaging model, we will explore how the uncertainties in the probe profile affect the estimation of the total scattered intensities. Using multislice image simulations, we analyze this effect for Cs corrected and non-Cs corrected microscopes as a function of inaccuracies in cylindrically symmetric aberrations, such as defocus and spherical aberration of third and fifth order, and non-cylindrically symmetric aberrations, such as 2-fold and 3-fold astigmatism and coma. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Oxford |
Editor |
|
|
|
Language |
|
Wos |
000338402500011 |
Publication Date |
2014-01-02 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0968-4328; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.98 |
Times cited |
25 |
Open Access |
|
|
|
Notes |
FWO (G.0393.11; G.0064.10; G.0374.13; G.0044.13); European Research Council under the 7th Framework Program (FP7); ERC GrantNo. 246791-COUNTATOMS and ERC Starting Grant No. 278510-VORTEX. A.R. thanks the DFG under contract number RO2057/8-1.The research leading to these results has received funding fromthe European Union 7th Framework Programme [FP7/2007-2013]under grant agreement no. 312483 (ESTEEM2).; esteem2ta ECASJO; |
Approved |
Most recent IF: 1.98; 2014 IF: 1.988 |
|
|
Call Number |
UA @ lucian @ c:irua:113857UA @ admin @ c:irua:113857 |
Serial |
831 |
|
Permanent link to this record |
|
|
|
|
Author |
Béché, A.; Winkler, R.; Plank, H.; Hofer, F.; Verbeeck, J. |
|
|
Title |
Focused electron beam induced deposition as a tool to create electron vortices |
Type |
A1 Journal article |
|
Year |
2015 |
Publication |
Micron |
Abbreviated Journal |
Micron |
|
|
Volume |
80 |
Issue |
80 |
Pages |
34-38 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
Focused electron beam induced deposition (FEBID) is a microscopic technique that allows geometrically controlled material deposition with very high spatial resolution. This technique was used to create a spiral aperture capable of generating electron vortex beams in a transmission electron microscope (TEM). The vortex was then fully characterized using different TEM techniques, estimating the average orbital angular momentum to be approximately 0.8variant Planck's over 2pi per electron with almost 60% of the beam ending up in the l=1 state. |
|
|
Address |
EMAT, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Wos |
000366770100006 |
Publication Date |
2015-09-12 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0968-4328; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.98 |
Times cited |
21 |
Open Access |
|
|
|
Notes |
A.B and J.V. acknowledge funding from the European Research Council under the 7th Framework Program (FP7), ERC Starting Grant No. 278510 VORTEX. J.V., R.W., H.P. and F.H. acknowledge financial support from the European Union under the 7th Framework Program (FP7) under a contract for an Integrated Infrastructure Initiative (Reference No. 312483 ESTEEM2). R.W and H.P also acknowledge financial support by the COST action CELINA (Nr. CM1301) and the EUROSTARS project TRIPLE-S (Nr. E!8213). The Qu-Ant-EM microscope was partly funded by the Hercules fund from the Flemish Government.; esteem2jra3 ECASJO; |
Approved |
Most recent IF: 1.98; 2015 IF: 1.988 |
|
|
Call Number |
c:irua:129203 c:irua:129203UA @ admin @ c:irua:129203 |
Serial |
3946 |
|
Permanent link to this record |
|
|
|
|
Author |
Cooper, D.; Denneulin, T.; Bernier, N.; Béché, A.; Rouvière, J.-L. |
|
|
Title |
Strain mapping of semiconductor specimens with nm-scale resolution in a transmission electron microscope |
Type |
A1 Journal article |
|
Year |
2016 |
Publication |
Micron |
Abbreviated Journal |
Micron |
|
|
Volume |
80 |
Issue |
80 |
Pages |
145-165 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
The last few years have seen a great deal of progress in the development of transmission electron microscopy based techniques for strain mapping. New techniques have appeared such as dark field electron holography and nanobeam diffraction and better known ones such as geometrical phase analysis have been improved by using aberration corrected ultra-stable modern electron microscopes. In this paper we apply dark field electron holography, the geometrical phase analysis of high angle annular dark field scanning transmission electron microscopy images, nanobeam diffraction and precession diffraction, all performed at the state-of-the-art to five different types of semiconductor samples. These include a simple calibration structure comprising 10-nm-thick SiGe layers to benchmark the techniques. A SiGe recessed source and drain device has been examined in order to test their capabilities on 2D structures. Devices that have been strained using a nitride stressor have been examined to test the sensitivity of the different techniques when applied to systems containing low values of deformation. To test the techniques on modern semiconductors, an electrically tested device grown on a SOI wafer has been examined. Finally a GaN/AlN superlattice was tested in order to assess the different methods of measuring deformation on specimens that do not have a perfect crystalline structure. The different deformation mapping techniques have been compared to one another and the strengths and weaknesses of each are discussed. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Oxford |
Editor |
|
|
|
Language |
|
Wos |
000366770100018 |
Publication Date |
2015-09-15 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0968-4328 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.98 |
Times cited |
50 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 1.98 |
|
|
Call Number |
UA @ lucian @ c:irua:136446 |
Serial |
4401 |
|
Permanent link to this record |
|
|
|
|
Author |
Samaeeaghmiyoni, V.; Idrissi, H.; Groten, J.; Schwaiger, R.; Schryvers, D. |
|
|
Title |
Quantitative in-situ TEM nanotensile testing of single crystal Ni facilitated by a new sample preparation approach |
Type |
A1 Journal article |
|
Year |
2017 |
Publication |
Micron |
Abbreviated Journal |
Micron |
|
|
Volume |
94 |
Issue |
94 |
Pages |
66-73 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
Twin-jet electro-polishing and Focused Ion Beam (FIB) were combined to produce small size Nickel single crystal specimens for quantitative in-situ nanotensile experiments in the transmission electron microscope. The combination of these techniques allows producing samples with nearly defect-free zones in the centre in contrast to conventional FIB-prepared samples. Since TEM investigations can be performed on the electro-polished samples prior to in-situ TEM straining, specimens with desired crystallographic orientation and initial microstructure can be prepared. The present results reveal a dislocation nucleation controlled plasticity, in which small loops induced by FIB near the edges of the samples play a central role. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000393247300008 |
Publication Date |
2016-12-21 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0968-4328 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.98 |
Times cited |
11 |
Open Access |
OpenAccess |
|
|
Notes |
This research has been performed with the financial support of the Belgian Science Policy (Belspo) under the framework of the interuniversity attraction poles program, IAP7/21. Financial support from the Flemish (FWO) and German Research Foundation (DFG) through the European M-ERA.NET project “FaSS” (Fatigue Simulation near Surfaces) under the grant numbers GA.014.13N and SCHW855/5-1, respectively, is gratefully acknowledged. V. Samaeeaghmiyoni also acknowledges the FWO research project G012012N “Understanding nanocrystalline mechanical behaviour from structural investigations”. H. Idrissi is currently mandated by the Belgian National Fund for Scientific Research (FSR-FNRS). |
Approved |
Most recent IF: 1.98 |
|
|
Call Number |
EMAT @ emat @ c:irua:139515 |
Serial |
4341 |
|
Permanent link to this record |
|
|
|
|
Author |
Godet, M.; Vergès-Belmin, V.; Gauquelin, N.; Saheb, M.; Monnier, J.; Leroy, E.; Bourgon, J.; Verbeeck, J.; Andraud, C. |
|
|
Title |
Nanoscale investigation by TEM and STEM-EELS of the laser induced yellowing |
Type |
A1 Journal article |
|
Year |
2018 |
Publication |
Micron |
Abbreviated Journal |
Micron |
|
|
Volume |
115 |
Issue |
|
Pages |
25-31 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
Nd-YAG QS laser cleaning of soiled stone at 1064 nm can sometimes result in a more yellow appearance compared to other cleaning techniques. Especially in France, this yellowing effect is still considered as a major aesthetic issue by the architects and conservators. One explanation states that the yellowing is linked to the formation of iron-rich nanophase(s) through the laser beam interaction with black crusts that would re-deposit on the cleaned substrate after irradiation. To characterize these nanophases, a model crust containing hematite was elaborated and laser irradiated using a Nd-YAG QS laser. The color of the sample shifted instantaneously from red to a bright yellow and numerous particles were ablated in a visible smoke. Transmission electron microscopy (TEM) was used to examine the morphology and the crystallinity of the neo-formed compounds, both on the surface of the samples and in the ablated materials. In addition, an investigation of the chemical and structural properties of the nanophases was conducted by X-ray dispersive energy (EDX) and electron energy loss (EELS) spectroscopies. It was found that both the surface of the sample and the ablated materials are covered by crystallized nano-spheres and nano-residues, all containing iron and oxygen, sometimes along with calcium and sulfur. In particular an interfacial area containing the four elements was evidenced between some nanostructures and the substrate. Magnetite Fe3O4 was also identified at the nanoscale. This study demonstrates that the laser yellowing of a model crust is linked to the presence of iron-rich nanophases including CaxFeySzOδ nanostructures and magnetite Fe3O4 at the surface after irradiation. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000449125600004 |
Publication Date |
2018-08-18 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0968-4328 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.98 |
Times cited |
9 |
Open Access |
Not_Open_Access: Available from 19.08.2020
|
|
|
Notes |
The authors wish to thank Valérie Lalanne for the sample preparation for TEM and Stijn Van den Broeck for the FIB cut elaboration. The research leading to these results has received funding from the European Union Seventh Framework Programme under Grant Agreement 312483 – ESTEEM2 (Integrated Infrastructure Initiative–I3). |
Approved |
Most recent IF: 1.98 |
|
|
Call Number |
EMAT @ emat @c:irua:154356UA @ admin @ c:irua:154356 |
Serial |
5056 |
|
Permanent link to this record |
|
|
|
|
Author |
De Meyer, R.; Albrecht, W.; Bals, S. |
|
|
Title |
Effectiveness of reducing the influence of CTAB at the surface of metal nanoparticles during in situ heating studies by TEM |
Type |
A1 Journal article |
|
Year |
2021 |
Publication |
Micron |
Abbreviated Journal |
Micron |
|
|
Volume |
144 |
Issue |
|
Pages |
103036 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
|
|
Abstract |
In situ TEM is a valuable technique to offer novel insights in the behavior of nanomaterials under various conditions. However, interpretation of in situ experiments is not straightforward since the electron beam can impact the outcome of such measurements. For example, ligands surrounding metal nanoparticles transform into a protective carbon layer upon electron beam irradiation and may impact the apparent thermal stability during in situ heating experiments. In this work, we explore the effect of different treatments typically proposed to remove such ligands. We found that plasma treatment prior to heating experiments for Au nanorods and nanostars increased the apparent thermal stability of the nanoparticles, while an activated carbon treatment resulted in a decrease of the observed thermal stability. Treatment with HCl barely changed the experimental outcome. These results demonstrate the importance of carefully selecting pre-treatments procedures during in situ heating experiments. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000632282600002 |
Publication Date |
2021-02-19 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0968-4328 |
ISBN |
|
Additional Links |
UA library record; WoS full record |
|
|
Impact Factor |
1.98 |
Times cited |
|
Open Access |
OpenAccess |
|
|
Notes |
H2020; European Research Council; This work was supported by the European Union’s Horizon 2020 research and innovation program [grant agreement No 823717 (ESTEEM3) and No 815128 (REALNANO)]; We acknowledge Prof. Luis M. Liz-Marzán and co-workers of the Bionanoplasmonics Laboratory, CICbiomaGUNE, Spain for providing the Au nanoparticles.; sygma; esteem3jra; esteem3reported |
Approved |
Most recent IF: 1.98 |
|
|
Call Number |
EMAT @ emat @c:irua:175874 |
Serial |
6677 |
|
Permanent link to this record |