toggle visibility
Search within Results:
Display Options:

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Vincze, L.; Vekemans, B.; Adams, F. openurl 
  Title (up) Synchrotron computed X-ray fluorescence tomography in environmental and earth sciences: radiation Type P3 Proceeding
  Year 2004 Publication Abbreviated Journal  
  Volume Issue Pages  
  Keywords P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos Publication Date  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Additional Links UA library record  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:46497 Serial 8633  
Permanent link to this record
 

 
Author Adams, F.; Vincze, L.; Vekemans, B. openurl 
  Title (up) Synchrotron radiation for microscopic X-ray fluorescence analysis Type H3 Book chapter
  Year 2004 Publication Abbreviated Journal  
  Volume Issue Pages 343-353 T2 - X-ray spectrometry: recent technologi  
  Keywords H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos Publication Date  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Additional Links UA library record  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:46499 Serial 8634  
Permanent link to this record
 

 
Author Janssens, K.; Vincze, L.; Vekemans, B.; Aerts, A.; Adams, F.; Jones, K.W.; Knöchel, A. openurl 
  Title (up) Synchrotron radiation induced X-ray microfluorescence analysis Type A1 Journal article
  Year 1996 Publication Microchimica acta T2 – 4th Workshop of the European-Microanalysis-Society on Modern, Developments and Applications in Microbeam Analysis, MAY, 1995, ST MALO, FRANCE Abbreviated Journal 4th Workshop of the European-Microanalysis-Society on Modern, Developments and Applications in Micro  
  Volume Issue s:[13] Pages 87-115  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract mu-XRF is the microscopic equivalent of the well-established multielement analytical technique. In this paper, after comparing the interaction of X-ray photons, electrons and protons with matter and an introduction to synchrotron rings and microfocussing of X-rays, the instrumentation for mu-XRF is discussed, both for laboratory source and synchrotron based setups and the analytical characteristics of mu-XRF are contrasted to that of other microanalytical techniques, Also, this issue of quantification of mu-XRF data is addressed; the applicability of the method in archeological and geological analysis is illustrated.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1996VT82300006 Publication Date  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:104410 Serial 5866  
Permanent link to this record
 

 
Author Janssens, K.; Vincze, L.; Adams, F.; Jones, K.W. doi  openurl
  Title (up) Synchrotron radiation-induced X-ray microanalysis Type A1 Journal article
  Year 1993 Publication Analytica chimica acta Abbreviated Journal  
  Volume 283 Issue Pages 98-119  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1993MK02800009 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2670 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:6107 Serial 5865  
Permanent link to this record
 

 
Author Schalm, O.; Crabbé, A.; Storme, P.; Wiesinger, R.; Gambirasi, A.; Grieten, E.; Tack, P.; Bauters, S.; Kleber, C.; Favaro, M.; Schryvers, D.; Vincze, L.; Terryn, H.; Patelli, A. pdf  url
doi  openurl
  Title (up) The corrosion process of sterling silver exposed to a Na2S solution: monitoring and characterizing the complex surface evolution using a multi-analytical approach Type A1 Journal article
  Year 2016 Publication Applied Physics A-Materials Science & Processing Abbreviated Journal Appl Phys A-Mater  
  Volume 122 Issue 122 Pages 903  
  Keywords A1 Journal article; Electron Microscopy for Materials Science (EMAT);  
  Abstract Many historical ‘silver’ objects are composed of sterling silver, a silver alloy containing small amounts of copper. Besides the dramatic impact of copper on the corrosion process, the chemical composition of the corrosion layer evolves continuously. The evolution of the surface during the exposure to a Na2S solution was monitored by means of visual observation at macroscopic level, chemical analysis at microscopic level and analysis at the nanoscopic level. The corrosion process starts with the preferential oxidation of copper, forming mixtures of oxides and sulphides while voids are being created beneath the corrosion layer. Only at a later stage, the silver below the corrosion layer is consumed. This results in the formation of jalpaite and at a later stage of acanthite. The acanthite is found inside the corrosion layer at the boundaries of jalpaite grains and as individual grains between the jalpaite grains but also as a thin film on top of the corrosion layer. The corrosion process could be described as a sequence of 5 subsequent surface states with transitions between these states.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000384753800033 Publication Date 2016-09-20  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0947-8396 ISBN Additional Links  
  Impact Factor 1.455 Times cited 9 Open Access  
  Notes The authors are grateful for the financial support by the EU-FP7 Grant PANNA No. 282998 and for the opportunity to perform SR-XPS measurements at the NanoESCA beamline of the Elettra storage ring, under the approval of the advisory Committee (Proposal No. 20135164), as well as the opportunity to perform XANES measurements at the DUBBLE beamline of the ESRF storage ring (Proposal No. 26-01-990). The authors are grateful for the financial support by the STIMPRO Project FFB150215 of the University of Antwerp. Pieter Tack is funded by a Ph.D. Grant of the Agency for Innovation by Science and Technology (IWT). We would also like to thank Peter Van den Haute for the XRD measurements that were performed at the University of Ghent. Approved Most recent IF: 1.455  
  Call Number EMAT @ emat @ Serial 4331  
Permanent link to this record
 

 
Author Janssens, K.; Vincze, L.; Vekemans, B.; Williams, C.T.; Radtke, M.; Haller, M.; Knöchel, A. pdf  doi
openurl 
  Title (up) The non-destructive determination of REE in fossilized bone using synchrotron radiation induced K-line X-ray microfluorescence analysis Type A1 Journal article
  Year 1999 Publication Fresenius' journal of analytical chemistry Abbreviated Journal  
  Volume 363 Issue 4 Pages 413-420  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract The sensitivity and applicability of the synchrotron radiation induced X-ray microfluorescence (mu-SRXRF) spectrometer at the Hamburg synchrotron laboratory Hasylab for the determination of the distribution of trace concentrations of rare-earth elements (REE) in fossilized bone are discussed and critically compared to those of other trace analytical methods such as instrumental neutron activation analysis (INAA) and LAMP-ICPMS (laser ablation microprobe inductively-coupled plasma mass spectrometry). Measurements were carried out on two bone samples from contrasting terrestrial depositional environments at Olduvai Gorge (Tanzania). Results indicate that the microdistribution of the REE in these biological materials is not homogeneous and that the relative abundance of these elements can provide information on the palaeoenvironment during the fossilization process. The heterogeneous distribution of the REE can be determined in a quantitative and completely non-destructive manner provided the concentrations of individual REE are above 10 mu g/g.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000078895300015 Publication Date 2002-08-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0937-0633 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved Most recent IF: NA  
  Call Number UA @ admin @ c:irua:103505 Serial 5747  
Permanent link to this record
 

 
Author Jochum, K.P.; Dingwell, D.B.; Rocholl, A.; Janssens, K.; Vincze, L.; et al. pdf  doi
openurl 
  Title (up) The preparation and preliminary characterisation of eight geological MPI-DING reference glasses for in-site microanalysis Type A1 Journal article
  Year 2000 Publication Geostandards newsletter Abbreviated Journal  
  Volume 24 Issue 1 Pages 87-133  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Eight silicate glasses were prepared by directly fusing and stirring 50-100 g each of basalt, andesite, komatiite, peridotite, rhyolite, and quartz-diorite. These are referred to as MPI-DING glasses and were made for the purpose of providing reference materials for geochemical, in-situ microanalytical work. Results from various analytical techniques indicate that individual glass fragments are well homogenised with respect to major and trace elements at the mu m to mm scale. Heterogeneities due to quench crystallisation of olivine have been observed in small and limited areas of the two komatiitic glasses. In order to obtain concentration values for as many elements as possible, the glasses were analysed by a variety of bulk and microanalytical methods in a number of laboratories. From the analytical data, preliminary reference values for more than sixty elements were calculated. The analytical uncertainties of most elements are estimated to be between 1% and 10%.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000088900000010 Publication Date 2007-05-23  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0150-5505 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved Most recent IF: NA  
  Call Number UA @ admin @ c:irua:104244 Serial 5787  
Permanent link to this record
 

 
Author Janssens, K.; Vincze, L.; Vekemans, B.; Adams, F.; Haller, M.; Knöchel, A. doi  openurl
  Title (up) The use of lead-glass capillaries for microfocusing of highly energetic (0-60 KeV) synchrotron radiation Type A1 Journal article
  Year 1998 Publication Journal of analytical atomic spectrometry Abbreviated Journal J Anal Atom Spectrom  
  Volume 13 Issue 5 Pages 339-350  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000073808900004 Publication Date 2002-07-26  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0267-9477 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 3.379 Times cited Open Access  
  Notes Approved Most recent IF: 3.379; 1998 IF: 3.845  
  Call Number UA @ admin @ c:irua:19321 Serial 5895  
Permanent link to this record
 

 
Author Kempenaers, L.; Vincze, L.; Janssens, K. doi  openurl
  Title (up) The use of synchrotron micro-XRF for characterisation of the micro-heterogeneity of low-Z reference materials Type A1 Journal article
  Year 2000 Publication Spectrochimica acta: part B : atomic spectroscopy Abbreviated Journal Spectrochim Acta B  
  Volume 55 Issue Pages 651-669  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000087765700008 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0584-8547; 0038-6987 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 3.241 Times cited Open Access  
  Notes Approved Most recent IF: 3.241; 2000 IF: 2.608  
  Call Number UA @ admin @ c:irua:28445 Serial 5900  
Permanent link to this record
 

 
Author Kempenaers, L.; Vincze, L.; Janssens, K. openurl 
  Title (up) The use of synchrotron micro-XRF for characterisation of the micro-heterogeneity of low-Z reference materials containing heavy metals Type H3 Book chapter
  Year 1999 Publication Abbreviated Journal  
  Volume Issue Pages  
  Keywords H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos Publication Date  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Additional Links UA library record  
  Impact Factor Times cited Open Access  
  Notes Approved Most recent IF: NA  
  Call Number UA @ admin @ c:irua:28443 Serial 5901  
Permanent link to this record
 

 
Author Vincze, L.; Vekemans, B.; Brenker, F.E.; Falkenberg, G.; Rickers, K.; Somogyi, A.; Kersten, M.; Adams, F. doi  openurl
  Title (up) Three-dimensional trace element analysis by confocal X-ray microfluorescence imaging Type A1 Journal article
  Year 2004 Publication Analytical chemistry Abbreviated Journal  
  Volume 76 Issue 22 Pages 6786-6791  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000225076400034 Publication Date 2004-11-12  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2700; 5206-882x ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:49817 Serial 8669  
Permanent link to this record
 

 
Author de Raedt, I.; Janssens, K.; Veeckman, J.; Vincze, L.; Vekemans, B.; Jeffries, T. doi  openurl
  Title (up) Trace analysis allows to distinguish between Venetian and facon-de-Venise glass vessels of the 16th and 17th century Type A1 Journal article
  Year 2001 Publication Journal of analytical atomic spectrometry Abbreviated Journal J Anal Atom Spectrom  
  Volume 16 Issue 9 Pages 1012-1017  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000171287600020 Publication Date 2002-07-26  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0267-9477 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 3.379 Times cited 49 Open Access  
  Notes Approved Most recent IF: 3.379; 2001 IF: 3.305  
  Call Number UA @ admin @ c:irua:34090 Serial 5878  
Permanent link to this record
 

 
Author Vincze, L.; Janssens, K.; Wei, F.; Proost, K.; Vekemans, B.; Vittiglio, G.; Yan, Y.; Falkenberg, G. openurl 
  Title (up) Trace-level micro-XANES by means of bending magnets radiation focused with a polycapillary lens Type H3 Book chapter
  Year 1999 Publication Abbreviated Journal  
  Volume Issue Pages  
  Keywords H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos Publication Date  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Additional Links UA library record  
  Impact Factor Times cited Open Access  
  Notes Approved Most recent IF: NA  
  Call Number UA @ admin @ c:irua:28440 Serial 5880  
Permanent link to this record
 

 
Author Janssens, K.; Vittiglio, G.; Deraedt, I.; Aerts, A.; Vekemans, B.; Vincze, L.; Wei, F.; de Ryck, I.; Schalm, O.; Adams, F.; Rindby, A.; Knöchel, A.; Simionovici, A.S.; Snigirev, A. doi  openurl
  Title (up) Use of microscopic XRF for non-destructive analysis in art an archaeometry Type A1 Journal article
  Year 2000 Publication X-ray spectrometry Abbreviated Journal X-Ray Spectrom  
  Volume 29 Issue Pages 73-91  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000085107800010 Publication Date 2002-08-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0049-8246 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 1.298 Times cited Open Access  
  Notes Approved Most recent IF: 1.298; 2000 IF: 1.478  
  Call Number UA @ admin @ c:irua:27561 Serial 5897  
Permanent link to this record
 

 
Author Vincze, L.; Vekemans, B.; Szaloki, I.; Brenker, F.E.; Falkenberg, G.; Rickers, K.; Aerts, K.; Van Grieken, R.; Adams, F. doi  openurl
  Title (up) X-ray fluorescence microtomography and polycapillary based confocal imaging using synchrotron radiation Type P1 Proceeding
  Year 2004 Publication Abbreviated Journal  
  Volume Issue Pages 220-231 T2 - 4th Conference on Developments in X-R  
  Keywords P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Ibis work illustrates the development of X-ray fluorescence tomography and polycapillary based confocal imaging towards a three-dimensional (313), quantitative analytical method with lateral resolution levels down to the 2-20 mum scale. Detailed analytical characterization is given for polycapillary based confocal XRF imaging, which is a new variant of the 3D micro-XRF technique. Applications for 2D/3D micro-XR-F are illustrated for the analysis of biological (zooplankton) and geological samples (microscopic inclusions in natural diamonds and fluid inclusions in quartz). Based on confocal imaging, fully three-dimensional distributions of trace elements could be obtained, representing a significant generalization of the regular 2D scanning technique for micro-XRF spectroscopy. The experimental work described in this paper has been carried out at the ESRF ID18F microfluorescence end-station and at HASYLAB Beam Line L.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000225665000023 Publication Date 2004-11-02  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0-8194-5473-7 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:94812 Serial 8767  
Permanent link to this record
 

 
Author Vincze, L.; Janssens, K.; Adams, F. openurl 
  Title (up) X-ray optics for synchrotron-radiation-induced X-ray micro fluorescence at the european synchrotron-radiation facility, Grenoble Type A1 Journal article
  Year 1993 Publication Institute of physics conference series Abbreviated Journal  
  Volume Issue 130 Pages 613-616  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Different optical designs for generating synchrotron x-ray micro beams suitable for use in an X-ray fluorescence microscope using an ESRF bending magnet X-ray source are compared. Attention is devoted to the spatial and energy distribution of the photons in the micro beam and to the minimum detection limits that are achievable with each alternative optical system.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1993LW34000126 Publication Date  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0305-2346 ISBN Additional Links UA library record; WoS full record  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:104541 Serial 5917  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: