|
“Observation of exciton states in silver halide nanoparticles by cryo-electron spectroscopic imaging and electron energy-loss spectroscopy”. Oleshko VP, Brichkin SB, Gijbels R, Jacob WA, Razumov VF, Mendeleev communications 7, 213 (1997)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.741
Times cited: 5
|
|
|
“Occurrence of gas flow rotational motion inside the ICP torch : a computational and experimental study”. Aghaei M, Flamigni L, Lindner H, Günther D, Bogaerts A, Journal of analytical atomic spectrometry 29, 249 (2014). http://doi.org/10.1039/c3ja50302j
Abstract: An inductively coupled plasma, connected to the sampling cone of a mass spectrometer, is computationally investigated. The occurrence of rotational motion of the auxiliary and carrier gas flows is studied. The effects of operating parameters, i.e., applied power and gas flow rates, as well as geometrical parameters, i.e., sampler orifice diameter and injector inlet diameter, are investigated. Our calculations predict that at higher applied power the auxiliary and carrier gas flows inside the torch move more forward to the sampling cone, which is validated experimentally for the auxiliary gas flow, by means of an Elan 6000 ICP-MS. Furthermore, an increase of the gas flow rates can also modify the occurrence of rotational motion. This is especially true for the carrier gas flow rate, which has a more pronounced effect to reduce the backward motion than the flow rates of the auxiliary and cooling gas. Moreover, a larger sampler orifice (e.g., 2 mm instead of 1 mm) reduces the backward flow of the auxiliary gas path lines. Finally, according to our model, an injector inlet of 2 mm diameter causes more rotations in the carrier gas flow than an injector inlet diameter of 1.5 mm, which can be avoided again by changing the operating parameters.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 21
DOI: 10.1039/c3ja50302j
|
|
|
“On the effect of centrifugal stretching on the rotational partition function of an asymmetric top”. Martin JML, François JP, Gijbels R, The journal of chemical physics 95, 8374 (1991)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.952
Times cited: 12
|
|
|
“On the heat formation of C8 and higher carbon clusters (letter to the editor)”. Martin JML, François JP, Gijbels R, The journal of chemical physics 95, 9420 (1991)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.952
Times cited: 27
|
|
|
“On the low-temperature growth mechanism of single walled carbon nanotubes in plasma enhanced chemical vapor deposition”. Shariat M, Shokri B, Neyts EC, Chemical physics letters 590, 131 (2013). http://doi.org/10.1016/j.cplett.2013.10.061
Abstract: Despite significant progress in single walled carbon nanotube (SWCNT) production by plasma enhanced chemical vapor deposition (PECVD), the growth mechanism in this method is not clearly understood. We employ reactive molecular dynamics simulations to investigate how plasma-based deposition allows growth at low temperature. We first investigate the SWCNT growth mechanism at low and high temperatures under conditions similar to thermal CVD and PECVD. We then show how ion bombardment during the nucleation stage increases the carbon solubility in the catalyst at low temperature. Finally, we demonstrate how moderate energy ions sputter amorphous carbon allowing for SWCNT growth at 500 K. (C) 2013 Elsevier B. V. All rights reserved.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.815
Times cited: 14
DOI: 10.1016/j.cplett.2013.10.061
|
|
|
“On the quasi-random entropy of linear species”. Slanina Z, Martin JML, François JP, Gijbels R, Theochem: applications of theoretical chemistry to organic, inorganic and biological problems 99, 83 (1993)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“On the reaction behaviour of hydrocarbon species at diamond (1 0 0) and (1 1 1) surfaces: a molecular dynamics investigation”. Eckert M, Neyts E, Bogaerts A, Journal of physics: D: applied physics 41, 032006 (2008). http://doi.org/10.1088/0022-3727/41/3/032006
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.588
Times cited: 17
DOI: 10.1088/0022-3727/41/3/032006
|
|
|
“On the regime transitions during the formation of an atmospheric pressure dielectric barrier glow discharge”. Martens T, Brok WJM, van Dijk J, Bogaerts A, Journal of physics: D: applied physics 42, 122002 (2009). http://doi.org/10.1088/0022-3727/42/12/122002
Abstract: The atmospheric pressure dielectric barrier discharge in helium is a pulsed discharge in nature. If during the electrical current pulse a glow discharge is reached, then this pulse will last only a few microseconds in operating periods of sinusoidal voltage with lengths of about 10 to 100 µs. In this paper we demonstrate that right before a glow discharge is reached, the discharge very closely resembles the commonly assumed Townsend discharge structure, but actually contains some significant differing features and hence should not be considered as a Townsend discharge. In order to clarify this, we present calculation results of high time and space resolution of the pulse formation. The results indicate that indeed a maximum of ionization is formed at the anode, but that the level of ionization remains high and that the electric field at that time is significantly disturbed. Our results also show where this intermediate structure comes from.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.588
Times cited: 21
DOI: 10.1088/0022-3727/42/12/122002
|
|
|
“On the relative stabilities of the linear and triangular forms of B3N”. Slanina Z, Martin JML, François JP, Gijbels R, Chemical physics 178, 77 (1993). http://doi.org/10.1016/0301-0104(93)85052-A
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.652
Times cited: 9
DOI: 10.1016/0301-0104(93)85052-A
|
|
|
“On the structure, stability and infrared spectrum of B2N, B2N+, B2N-, BO, B2O and B2N2”. Martin JML, François JP, Gijbels R, Chemical physics letters 193, 243 (1992). http://doi.org/10.1016/0009-2614(92)85662-T
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.897
Times cited: 42
DOI: 10.1016/0009-2614(92)85662-T
|
|
|
“On the time scale associated with Monte Carlo simulations”. Bal KM, Neyts EC, The journal of chemical physics 141, 204104 (2014). http://doi.org/10.1063/1.4902136
Abstract: Uniform-acceptance force-bias Monte Carlo (fbMC) methods have been shown to be a powerful technique to access longer timescales in atomistic simulations allowing, for example, phase transitions and growth. Recently, a new fbMC method, the time-stamped force-bias Monte Carlo (tfMC) method, was derived with inclusion of an estimated effective timescale; this timescale, however, does not seem able to explain some of the successes the method. In this contribution, we therefore explicitly quantify the effective timescale tfMC is able to access for a variety of systems, namely a simple single-particle, one-dimensional model system, the Lennard-Jones liquid, an adatom on the Cu(100) surface, a silicon crystal with point defects and a highly defected graphene sheet, in order to gain new insights into the mechanisms by which tfMC operates. It is found that considerable boosts, up to three orders of magnitude compared to molecular dynamics, can be achieved for solid state systems by lowering of the apparent activation barrier of occurring processes, while not requiring any system-specific input or modifications of the method. We furthermore address the pitfalls of using the method as a replacement or complement of molecular dynamics simulations, its ability to explicitly describe correct dynamics and reaction mechanisms, and the association of timescales to MC simulations in general.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.965
Times cited: 26
DOI: 10.1063/1.4902136
|
|
|
“A one-dimensional fluid model for an acetylene rf discharge: a study of the plasma chemistry”. Herrebout D, Bogaerts A, Gijbels R, Goedheer WJ, Vanhulsel A, IEEE transactions on plasma science 31, 659 (2003). http://doi.org/10.1109/TPS.2003.815249
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.052
Times cited: 26
DOI: 10.1109/TPS.2003.815249
|
|
|
“One-dimensional modelling of a capacitively coupled rf plasma in silane/helium, including small concentrations of O2 and N2”. de Bleecker K, Herrebout D, Bogaerts A, Gijbels R, Descamps P, Journal of physics: D: applied physics 36, 1826 (2003)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.588
|
|
|
“Oppervlakte en in-diepte analyse via SIMS, SNMS en GDMS”. Gijbels R, Physicalia magazine 14, 49 (1992)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Optical bistability and multistability in four-level systems”. Chen Z, Feng X, Xu Y, Yu MY, Physica scripta 68, 199 (2003). http://doi.org/10.1238/Physica.Regular.068a00199
Abstract: The optical behavior of a four-level system in a ring cavity driven by two coherent laser fields is studied. One laser field is treated as the incident field and the other the control field, respectively. It is found that there is optical transparency when the difference between the two frequency detunings of the incident and control fields from the corresponding atomic transition frequencies is zero. Optical bistability can be produced and controlled by increasing the magnitude of the frequency difference. The bistable hysteresis becomes larger when the frequency difference is increased. Further increase of the latter can lead to onset of multistability.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.28
Times cited: 8
DOI: 10.1238/Physica.Regular.068a00199
|
|
|
“Optimization of operating parameters for inductively coupled plasma mass spectrometry : a computational study”. Aghaei M, Lindner H, Bogaerts A, Spectrochimica acta: part B : atomic spectroscopy 76, 56 (2012). http://doi.org/10.1016/j.sab.2012.06.006
Abstract: An inductively coupled plasma, connected to a mass spectrometer interface, is computationally investigated. The effect of pressure behind the sampler, injector gas flow rate, auxiliary gas flow rate, and applied power is studied. There seems to be an optimum range of injector gas flow rate for each setup which guaranties the presence and also a proper length of the central channel in the torch. Moreover, our modeling results show that for any specific purpose, it is possible to control that either only the central gas flow passes through the sampler orifice or that it is accompanied by the auxiliary gas flow. It was also found that depending on geometry, the variation of outgoing gas flow rate is much less than the variation of the injector gas flow rate and this causes a slightly higher pressure inside the torch. The general effect of increasing the applied power is a rise in the plasma temperature, which results in a higher ionization in the coil region. However, the negative effect is reducing the length of the cool central channel which is important to transfer the sample substances to the sampler. Using a proper applied power can enhance the efficiency of the system. Indeed, by changing the gas path lines, the power can control which flow (i.e., only from injector gas or also from the auxiliary gas) goes to the sampler orifice. Finally, as also reported from experiments in literature, the pressure behind the sampler has no dramatic effect on the plasma characteristics.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 18
DOI: 10.1016/j.sab.2012.06.006
|
|
|
“Optimized transport setup for high repetition rate pulse-separated analysis in laser ablation-inductively coupled plasma mass spectrometry”. Lindner H, Autrique D, Garcia CC, Niemax K, Bogaerts A, Analytical chemistry 81, 4241 (2009). http://doi.org/10.1021/ac802627x
Abstract: An optimized laser ablation setup, proposed for high repetition rate inductively coupled plasma mass spectrometry (ICPMS) analyses such as 2D imaging or depth profiling, is presented. For such applications, the particle washout time needs to be as short as possible to allow high laser pulse frequencies for reduced analysis time. Therefore, it is desirable to have an ablation setup that operates as a laminar flow reactor (LFR). A top-down strategy was applied that resulted in the present design. In the first step, a previously applied ablation setup was analyzed on the basis of computational fluid dynamics (CFD) results presented by D. Autrique et al. (Spectrochim. Acta, B 2008, 63, 257−270). By means of CFD simulations, the design was modified in such a way that it operated in the LFR regime. Experimental results demonstrate that the current design can indeed be regarded as an LFR. Furthermore, the operation under LFR conditions allowed some insight into the initial radial concentration distribution if the experimental ICPMS signal and analytical expressions are taken into account. Recommendations for a modified setup for more resilient spatial distributions are given. With the present setup, a washout time of 140 ms has been achieved for a 3% signal area criterion. Therefore, 7 Hz repetition rates can be applied with the present setup. Using elementary formulas of the analytical model, an upper bound for the washout times for similar setups can be predicted. The authors believe that the presented setup geometry comes close to the achievable limit for reliable short washout times.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 18
DOI: 10.1021/ac802627x
|
|
|
“Organic SIMS: the influence of time on the ion yield enhancement by silver and gold deposition”. Adriaensen L, Vangaever F, Gijbels R, Applied surface science 231/232, 256 (2004). http://doi.org/10.1016/j.apsusc.2004.03.031
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.387
Times cited: 10
DOI: 10.1016/j.apsusc.2004.03.031
|
|
|
“The origin of Bohm diffusion, investigated by a comparison of different modelling methods”. Bultinck E, Mahieu S, Depla D, Bogaerts A, Journal of physics: D: applied physics 43, 292001 (2010). http://doi.org/10.1088/0022-3727/43/29/292001
Abstract: 'Bohm diffusion' causes the electrons to diffuse perpendicularly to the magnetic field lines. However, its origin is not yet completely understood: low and high frequency electric field fluctuations are both named to cause Bohm diffusion. The importance of including this process in a Monte Carlo (MC) model is demonstrated by comparing calculated ionization rates with particle-in-cell/Monte Carlo collisions (PIC/MCC) simulations. A good agreement is found with a Bohm diffusion parameter of 0.05, which corresponds well to experiments. Since the PIC/MCC method accounts for fast electric field fluctuations, we conclude that Bohm diffusion is caused by fast electric field phenomena.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.588
Times cited: 16
DOI: 10.1088/0022-3727/43/29/292001
|
|
|
“Oxidation of the GaAs(001) surface : insights from first-principles calculations”. Scarrozza M, Pourtois G, Houssa M, Heyns M, Stesmans A, Physical review : B : condensed matter and materials physics 85, 195307 (2012). http://doi.org/10.1103/PhysRevB.85.195307
Abstract: We performed a detailed investigation of the oxidation of the technologically relevant GaAs(001)-beta 2(2x4) surface via density functional calculations. The purpose is to gain insights on the atomistic mechanisms and local bondings that underlie the degradation of the surface properties once exposed to oxygen. The study comprises the adsorption of single O atoms, through the sampling of several adsorption sites, and the subsequent formation of the O adsorbate at increasing coverage by taking into account multiple-atom adsorption. Based on the evaluation of the energetics and the structural properties of the atomistic models generated, the results here reported delineate a consistent picture of the initial stage of the surface oxidation: (i) at low coverage, in the limit of single O insertions, oxygen is incorporated on the surface forming a twofold-bridging Ga-O-As bond; (ii) at increasing coverage, as multiple O atoms are involved, this is accompanied by the formation of a threefold-coordinated bond (with two Ga and one As atoms); (iii) the latter has important implications regarding the electronic properties of the adsorbate since this O bonding may result in the formation of As dangling bonds. Moreover, a clear trend of increased energy gain for the incorporation of neighboring O atoms compared to single O insertions indicates that the formation of oxide clusters is favored over a regime of uniform oxidation. Our findings provide a detailed description of the O bonding and stress the importance of modeling the adsorption of multiple O atoms for an accurate description of the surface oxidation.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.836
Times cited: 15
DOI: 10.1103/PhysRevB.85.195307
|
|
|
“Particle-in-cell/Monte Carlo collisions model for the reactive sputter deposition of nitride layers”. Bultinck E, Mahieu S, Depla D, Bogaerts A, Plasma processes and polymers 6, S784 (2009). http://doi.org/10.1002/ppap.200931904
Abstract: A 2d3v Particle-in-cell/Monte Carlo collisions (PIC/MCC) model was constructed for an Ar/N2 reactive gas mixture in a magnetron discharge. A titanium target was used, in order to study the sputter deposition of a TiNx thin film. Cathode currents and voltages were calculated self-consistently and compared with experiments. Also, ion fluxes to the cathode were calculated, which cause sputtering of the target. The sputtered atom fluxes from the target, and to the substrate were calculated, in order to visualize the deposition of the TiNx film.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.846
Times cited: 2
DOI: 10.1002/ppap.200931904
|
|
|
“Particle-in-cell/Monte Carlo collisions treatment of an Ar/O2 magnetron discharge used for the reactive sputter deposition of TiOx films”. Bultinck E, Bogaerts A, New journal of physics 11, 103010 (2009). http://doi.org/10.1088/1367-2630/11/10/103010
Abstract: The physical processes in an Ar/O2 magnetron discharge used for the reactive sputter deposition of TiOx thin films were simulated with a 2d3v particle-in-cell/Monte Carlo collisions (PIC/MCC) model. The plasma species taken into account are electrons, Ar+ ions, fast Arf atoms, metastable Arm* atoms, Ti+ ions, Ti atoms, O+ ions, O2+ ions, O− ions and O atoms. This model accounts for plasmatarget interactions, such as secondary electron emission and target sputtering, and the effects of target poisoning. Furthermore, the deposition process is described by an analytical surface model. The influence of the O2/Ar gas ratio on the plasma potential and on the species densities and fluxes is investigated. Among others, it is shown that a higher O2 pressure causes the region of positive plasma potential and the O− density to be more spread, and the latter to decrease. On the other hand, the deposition rates of Ti and O are not much affected by the O2/Ar proportion. Indeed, the predicted stoichiometry of the deposited TiOx film approaches x=2 for nearly all the investigated O2/Ar proportions.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.786
Times cited: 24
DOI: 10.1088/1367-2630/11/10/103010
|
|
|
“Particle-in-cell Monte Carlo modeling of Langmuir probes in an Ar plasma”. Cenian A, Chernukho A, Bogaerts A, Gijbels R, Leys C, Journal of applied physics 97, 123310 (2005). http://doi.org/10.1063/1.1938275
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 18
DOI: 10.1063/1.1938275
|
|
|
“Particle-in-cell/Monte Carlo simulation of a capacitively coupled radio frequency Ar/Cf4 discharge: effect of gas composition”. Georgieva V, Bogaerts A, Gijbels R, Journal of applied physics 93, 2369 (2003). http://doi.org/10.1063/1.1542920
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 57
DOI: 10.1063/1.1542920
|
|
|
“Particle-in-cell/Monte Carlo simulations of a low-pressure capacitively coupled radio-frequency discharge: effect of adding H2 to an Ar discharge”. Neyts E, Yan M, Bogaerts A, Gijbels R, Journal of applied physics 93, 5025 (2003). http://doi.org/10.1063/1.1563820
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 15
DOI: 10.1063/1.1563820
|
|
|
“Phase explosion in atmospheric pressure infrared laser ablation from water-rich targets”. Chen Z, Bogaerts A, Vertes A, Applied physics letters 89, 041503 (2006). http://doi.org/10.1063/1.2243961
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.411
Times cited: 32
DOI: 10.1063/1.2243961
|
|
|
“Phase modulation in pulsed dual-frequency capacitively coupled plasmas”. Wen D-Q, Zhang Q-Z, Jiang W, Song U-H, Bogaerts A, Wang Y-N, Journal of applied physics 115, 233303 (2014). http://doi.org/10.1063/1.4884225
Abstract: Particle-in-cell/Monte Carlo collision simulations, coupled with an external circuit, are used to investigate the behavior of pulsed dual-frequency (DF) capacitively coupled plasmas (CCPs). It is found that the phase shift θ between the high (or low) frequency source and the pulse modulation has a great influence on the ion density and the ionization rate. By pulsing the high frequency source, the time-averaged ion density shows a maximum when θ = 90∘. The time-averaged ion energy distribution functions (IEDFs) at the driven electrode, however, keep almost unchanged, illustrating the potential of pulsed DF-CCP for independent control of ion density (and flux) and ion energy. A detailed investigation of the temporal evolution of the plasma characteristics indicates that several high frequency harmonics can be excited at the initial stage of a pulse period by tuning the phase shift θ, and this gives rise to strong sheath oscillations, and therefore high ionization rates. For comparison, the pulsing of the low frequency source is also studied. In this case, the ion density changes slightly as a function of time, and the time-averaged ion density shows the same trend as in the HF modulation for different phase shifts θ. Moreover, the time-averaged IEDFs at the driven electrode can be modulated, showing the potential to reduce the maximum ion bombardment energy.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 8
DOI: 10.1063/1.4884225
|
|
|
“PIC-MC simulation of an RF capacitively coupled Ar/H2 discharge”. Neyts E, Yan M, Bogaerts A, Gijbels R, Nuclear instruments and methods in physics research: B 202, 300 (2003). http://doi.org/10.1016/S0168-583X(02)01873-6
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.109
Times cited: 8
DOI: 10.1016/S0168-583X(02)01873-6
|
|
|
“PIC –, MCC numerical simulation of a DC planar magnetron”. Kolev I, Bogaerts A, Plasma processes and polymers 3, 127 (2006). http://doi.org/10.1002/ppap.200500118
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.846
Times cited: 27
DOI: 10.1002/ppap.200500118
|
|
|
“Plasma-based dry reforming : improving the conversion and energy efficiency in a dielectric barrier discharge”. Snoeckx R, Zeng YX, Tu X, Bogaerts A, RSC advances 5, 29799 (2015). http://doi.org/10.1039/C5RA01100K
Abstract: Dry reforming of methane has gained significant interest over the years. A novel reforming technique with great potential is plasma technology. One of its drawbacks, however, is energy consumption. Therefore, we performed an extensive computational study, supported by experiments, aiming to identify the influence of the operating parameters (gas mixture, power, residence time and frequency) of a dielectric barrier discharge plasma on the conversion and energy efficiency, and to investigate which of these parameters lead to the most promising results and whether these are eventually sufficient for industrial implementation. The best results, in terms of both energy efficiency and conversion, are obtained at a specific energy input (SEI) of 100 J cm−3, a 1090 CH4CO2 ratio, 10 Hz, a residence time of 1 ms, resulting in a total conversion of 84% and an energy efficiency of 8.5%. In general, increasing the CO2 content in the gas mixture leads to a higher conversion and energy efficiency. The SEI couples the effect of the power and residence time, and increasing the SEI always results in a higher conversion, but somewhat lower energy efficiencies. The effect of the frequency is more complicated: we observed that the product of frequency (f) and residence time (τ), being a measure for the total number of micro-discharge filaments which the gas molecules experience when passing through the reactor, was critical. For most cases, a higher number of filaments yields higher values for conversion and energy efficiency. To benchmark our model predictions, we also give an overview of measured conversions and energy efficiencies reported in the literature, to indicate the potential for improvement compared to the state-of-the art. Finally, we identify the limitations as well as the benefits and future possibilities of plasma technology.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.108
Times cited: 67
DOI: 10.1039/C5RA01100K
|
|