|
Records |
Links |
|
Author |
Verbeeck, J.; van Dyck, D.; Lichte, H.; Potapov, P.; Schattschneider, P. |
|
|
Title |
Plasmon holographic experiments: theoretical framework |
Type |
A1 Journal article |
|
Year |
2005 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
|
|
Volume |
102 |
Issue |
3 |
Pages |
239-255 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
A theoretical framework is described to understand the results of plasmon holography experiments leading to insight in the meaning of the experimental results and pointing out directions for future experiments. The framework is based on the formalism of mutual intensity to describe how coherence is transferred through an optical system. For the inelastic interaction with the object, an expression for the volume. plasmon excitations in a free electron gas is used as a model for the behaviour of aluminium. The formalism leads to a clear graphical intuitive tool for under-standing the experiments. It becomes evident that the measured coherence is solely related to the angular distribution of the plasmon scattering in the case of bulk plasmons. After describing the framework, the special case of coherence outside a spherical particle is treated and the seemingly controversial idea of a plasmon with a limited coherence length obtained front experiments is clarified. (C) 2004 Elsevier B.V. All rights reserved. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
|
|
Language |
|
Wos |
000226436600010 |
Publication Date |
2004-11-05 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.843 |
Times cited |
43 |
Open Access |
|
|
|
Notes |
Fwo |
Approved |
Most recent IF: 2.843; 2005 IF: 2.490 |
|
|
Call Number |
UA @ lucian @ c:irua:57133UA @ admin @ c:irua:57133 |
Serial |
2643 |
|
Permanent link to this record |
|
|
|
|
Author |
Wang, A.; Van Aert, S.; Goos, P.; van Dyck, D. |
|
|
Title |
Precision of three-dimensional atomic scale measurements from HRTEM images : what are the limits? |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
|
|
Volume |
114 |
Issue |
|
Pages |
20-30 |
|
|
Keywords |
A1 Journal article; Engineering Management (ENM); Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
In this paper, we investigate to what extent high resolution transmission electron microscopy images can be used to measure the mass, in terms of thickness, and surface profile, corresponding to the defocus offset, of an object at the atomic scale. Therefore, we derive an expression for the statistical precision with which these object parameters can be estimated in a quantitative analysis. Evaluating this expression as a function of the microscope settings allows us to derive the optimal microscope design. Acquiring three-dimensional structure information in terms of thickness turns out to be much more difficult than obtaining two-dimensional information on the projected atom column positions. The attainable precision is found to be more strongly affected by processes influencing the image contrast, such as phonon scattering, than by the specific choice of microscope settings. For a realistic incident electron dose, it is expected that atom columns can be distinguished with single atom sensitivity up to a thickness of the order of the extinction distance. A comparable thickness limit is determined to measure surface steps of one atom. An increase of the electron dose shifts the limiting thickness upward due to an increase in the signal-to-noise ratio. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
|
|
Language |
|
Wos |
000301954300003 |
Publication Date |
2012-01-06 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.843 |
Times cited |
5 |
Open Access |
|
|
|
Notes |
Fwo |
Approved |
Most recent IF: 2.843; 2012 IF: 2.470 |
|
|
Call Number |
UA @ lucian @ c:irua:94116 |
Serial |
2692 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Aert, S.; Verbeeck, J.; Erni, R.; Bals, S.; Luysberg, M.; van Dyck, D.; Van Tendeloo, G. |
|
|
Title |
Quantitative atomic resolution mapping using high-angle annular dark field scanning transmission electron microscopy |
Type |
A1 Journal article |
|
Year |
2009 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
|
|
Volume |
109 |
Issue |
10 |
Pages |
1236-1244 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
A model-based method is proposed to relatively quantify the chemical composition of atomic columns using high angle annular dark field (HAADF) scanning transmission electron microscopy (STEM) images. The method is based on a quantification of the total intensity of the scattered electrons for the individual atomic columns using statistical parameter estimation theory. In order to apply this theory, a model is required describing the image contrast of the HAADF STEM images. Therefore, a simple, effective incoherent model has been assumed which takes the probe intensity profile into account. The scattered intensities can then be estimated by fitting this model to an experimental HAADF STEM image. These estimates are used as a performance measure to distinguish between different atomic column types and to identify the nature of unknown columns with good accuracy and precision using statistical hypothesis testing. The reliability of the method is supported by means of simulated HAADF STEM images as well as a combination of experimental images and electron energy-loss spectra. It is experimentally shown that statistically meaningful information on the composition of individual columns can be obtained even if the difference in averaged atomic number Z is only 3. Using this method, quantitative mapping at atomic resolution using HAADF STEM images only has become possible without the need of simultaneously recorded electron energy loss spectra. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
|
|
Language |
|
Wos |
000270015200004 |
Publication Date |
2009-05-28 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.843 |
Times cited |
166 |
Open Access |
|
|
|
Notes |
Fwo; Esteem 026019 |
Approved |
Most recent IF: 2.843; 2009 IF: 2.067 |
|
|
Call Number |
UA @ lucian @ c:irua:78585UA @ admin @ c:irua:78585 |
Serial |
2748 |
|
Permanent link to this record |
|
|
|
|
Author |
van den Broek, W.; Van Aert, S.; Goos, P.; van Dyck, D. |
|
|
Title |
Throughput maximization of particle radius measurements by balancing size and current of the electron probe |
Type |
A1 Journal article |
|
Year |
2011 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
|
|
Volume |
111 |
Issue |
7 |
Pages |
940-947 |
|
|
Keywords |
A1 Journal article; Engineering Management (ENM); Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
In thispaperweinvestigatewhichprobesizemaximizesthethroughputwhenmeasuringtheradiusof nanoparticlesinhighangleannulardarkfieldscanningtransmissionelectronmicroscopy(HAADFSTEM). The sizeandthecorrespondingcurrentoftheelectronprobedeterminetheprecisionoftheestimateofa particlesradius.Maximizingthroughputmeansthatamaximumnumberofparticlesshouldbeimaged withinagiventimeframe,sothataprespecifiedprecisionisattained.WeshowthatBayesianstatistical experimentaldesignisaveryusefulapproachtodeterminetheoptimalprobesizeusingacertainamount of priorknowledgeaboutthesample.Thedependenceoftheoptimalprobesizeonthedetectorgeometry and thediameter,variabilityandatomicnumberoftheparticlesisinvestigated.Anexpressionforthe optimalprobesizeintheabsenceofanykindofpriorknowledgeaboutthespecimenisderivedaswell. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
|
|
Language |
|
Wos |
000300461000026 |
Publication Date |
2010-11-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.843 |
Times cited |
7 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 2.843; 2011 IF: 2.471 |
|
|
Call Number |
UA @ lucian @ c:irua:89657 |
Serial |
3659 |
|
Permanent link to this record |
|
|
|
|
Author |
Lobato, I.; Van Dyck, D. |
|
|
Title |
MULTEM : a new multislice program to perform accurate and fast electron diffraction and imaging simulations using graphics processing units with CUDA |
Type |
A1 Journal article |
|
Year |
2015 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
|
|
Volume |
156 |
Issue |
156 |
Pages |
9-17 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
The main features and the GPU implementation of the MULTEM program are presented and described. This new program performs accurate and fast multislice simulations by including higher order expansion of the multislice solution of the high energy Schrodinger equation, the correct subslicing of the three-dimensional potential and top-bottom surfaces. The program implements different kinds of simulation for CTEM, STEM, ED, PED, CBED, ADF-TEM and ABF-HC with proper treatment of the spatial and temporal incoherences. The multislice approach described here treats the specimen as amorphous material which allows a straightforward implementation of the frozen phonon approximation. The generalized transmission function for each slice is calculated when is needed and then discarded. This allows us to perform large simulations that can include millions of atoms and keep the computer memory requirements to a reasonable level. (C) 2015 Elsevier B.V. All rights reserved. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
|
|
Language |
|
Wos |
000361001800003 |
Publication Date |
2015-04-28 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.843 |
Times cited |
32 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 2.843; 2015 IF: 2.436 |
|
|
Call Number |
UA @ lucian @ c:irua:127848 |
Serial |
4209 |
|
Permanent link to this record |
|
|
|
|
Author |
Alania, M.; De Backer, A.; Lobato, I.; Krause, F.F.; Van Dyck, D.; Rosenauer, A.; Van Aert, S. |
|
|
Title |
How precise can atoms of a nanocluster be located in 3D using a tilt series of scanning transmission electron microscopy images? |
Type |
A1 Journal article |
|
Year |
2017 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
|
|
Volume |
181 |
Issue |
181 |
Pages |
134-143 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
In this paper, we investigate how precise atoms of a small nanocluster can ultimately be located in three dimensions (3D) from a tilt series of images acquired using annular dark field (ADF) scanning transmission electron microscopy (STEM). Therefore, we derive an expression for the statistical precision with which the 3D atomic position coordinates can be estimated in a quantitative analysis. Evaluating this statistical precision as a function of the microscope settings also allows us to derive the optimal experimental design. In this manner, the optimal angular tilt range, required electron dose, optimal detector angles, and number of projection images can be determined. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000411170800016 |
Publication Date |
2016-12-15 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0304-3991 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.843 |
Times cited |
3 |
Open Access |
OpenAccess |
|
|
Notes |
The authors acknowledge financial support from the European Union under the Seventh Framework Program under a contract for an Integrated Infrastructure Initiative. Reference No. 312483-ESTEEM2. The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through project fundings (G.0374.13N, G.0369.15N, G.0368.15N, and WO.010.16N) and a post-doctoral grant to A. De Backer, and from the DFG under contract No. RO-2057/4-2. |
Approved |
Most recent IF: 2.843 |
|
|
Call Number |
EMAT @ emat @ c:irua:144432 |
Serial |
4618 |
|
Permanent link to this record |
|
|
|
|
Author |
Schalm, O.; van der Linden, V.; Frederickx, P.; Luyten, S.; van der Snickt, G.; Caen, J.; Schryvers, D.; Janssens, K.; Cornelis, E.; van Dyck, D.; Schreiner, M. |
|
|
Title |
Enamels in stained glass windows: preparation, chemical composition, microstructure and causes of deterioration |
Type |
A1 Journal article |
|
Year |
2009 |
Publication |
Spectrochimica acta: part B : atomic spectroscopy |
Abbreviated Journal |
Spectrochim Acta B |
|
|
Volume |
64 |
Issue |
8 |
Pages |
812-820 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Vision lab |
|
|
Abstract |
Stained glass windows incorporating dark blue and purple enamel paint layers are in some cases subject to severe degradation while others from the same period survived the ravages of time. A series of dark blue, greenblue and purple enamel glass paints from the same region (Northwestern Europe) and from the same period (16early 20th centuries) has been studied by means of a combination of microscopic X-ray fluorescence analysis, electron probe micro analysis and transmission electron microscopy with the aim of better understanding the causes of the degradation. The chemical composition of the enamels diverges from the average chemical composition of window glass. Some of the compositions appear to be unstable, for example those with a high concentration of K2O and a low content of CaO and PbO. In other cases, the deterioration of the paint layers was caused by the less than optimal vitrification of the enamel during the firing process. Recipes and chemical compositions indicate that glassmakers of the 1617th century had full control over the color of the enamel glass paints they made. They mainly used three types of coloring agents, based on Co (dark blue), Mn (purple) and Cu (light-blue or greenblue) as coloring elements. Bluepurple enamel paints were obtained by mixing two different coloring agents. The coloring agent for redpurple enamel, introduced during the 19th century, was colloidal gold embedded in grains of lead glass. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Oxford |
Editor |
|
|
|
Language |
|
Wos |
000269995300018 |
Publication Date |
2009-06-19 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0584-8547; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
3.241 |
Times cited |
28 |
Open Access |
|
|
|
Notes |
Iuap Vi/6; Fwo; Goa |
Approved |
Most recent IF: 3.241; 2009 IF: 2.719 |
|
|
Call Number |
UA @ lucian @ c:irua:79647 |
Serial |
1035 |
|
Permanent link to this record |
|
|
|
|
Author |
Verbeeck, J.; van Dyck, D.; Van Tendeloo, G. |
|
|
Title |
Energy-filtered transmission electron microscopy: an overview |
Type |
A1 Journal article |
|
Year |
2004 |
Publication |
Spectrochimica acta: part B : atomic spectroscopy |
Abbreviated Journal |
Spectrochim Acta B |
|
|
Volume |
59 |
Issue |
10/11 |
Pages |
1529-1534 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
This paper aims to give an overview of the technique of energy-filtered transmission electron microscopy (EFTEM). It explains the basic principles of the technique and points to the relevant literature for more detailed issues. Experimental examples are given to show the power of EFTEM to study the chemical composition of nanoscale samples in materials science. Advanced EFTEM applications like imaging spectroscopy and EFTEM tomography are briefly discussed. (C) 2004 Elsevier B.V. All rights reserved. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Oxford |
Editor |
|
|
|
Language |
|
Wos |
000224848000006 |
Publication Date |
2004-10-13 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0584-8547; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
3.241 |
Times cited |
37 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 3.241; 2004 IF: 3.086 |
|
|
Call Number |
UA @ lucian @ c:irua:54869UA @ admin @ c:irua:54869 |
Serial |
1038 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Aert, S.; van Dyck, D.; den Dekker, A.J. |
|
|
Title |
Resolution of coherent and incoherent imaging systems reconsidered: classical criteria and a statistical alternative |
Type |
A1 Journal article |
|
Year |
2006 |
Publication |
Optics express |
Abbreviated Journal |
Opt Express |
|
|
Volume |
14 |
Issue |
9 |
Pages |
3830-3839 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000237296200013 |
Publication Date |
2006-05-04 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1094-4087; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
3.307 |
Times cited |
45 |
Open Access |
|
|
|
Notes |
Fwo |
Approved |
Most recent IF: 3.307; 2006 IF: 4.009 |
|
|
Call Number |
UA @ lucian @ c:irua:58262 |
Serial |
2883 |
|
Permanent link to this record |
|
|
|
|
Author |
Cloetens, P.; Ludwig, W.; Baruchel, J.; van Dyck, D.; van Landuyt, J.; Guigay, J.P.; Schlenker, M. |
|
|
Title |
Holotomography: quantitative phase tomography with micrometer resolution using hard synchrotron radiation X-rays |
Type |
A1 Journal article |
|
Year |
1999 |
Publication |
Applied physics letters |
Abbreviated Journal |
Appl Phys Lett |
|
|
Volume |
75 |
Issue |
19 |
Pages |
2912-2914 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
American Institute of Physics |
Place of Publication |
New York, N.Y. |
Editor |
|
|
|
Language |
|
Wos |
000083483900014 |
Publication Date |
2002-07-26 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-6951; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
3.411 |
Times cited |
481 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 3.411; 1999 IF: 4.184 |
|
|
Call Number |
UA @ lucian @ c:irua:29643 |
Serial |
1484 |
|
Permanent link to this record |
|
|
|
|
Author |
van Dyck, D.; Croitoru, M.D. |
|
|
Title |
Statistical method for thickness measurement of amorphous objects |
Type |
A1 Journal article |
|
Year |
2007 |
Publication |
Applied physics letters |
Abbreviated Journal |
Appl Phys Lett |
|
|
Volume |
90 |
Issue |
24 |
Pages |
241911-241913 |
|
|
Keywords |
A1 Journal article; Condensed Matter Theory (CMT); Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
The authors propose a nondestructive method for the determination of the thickness of an amorphous sample. This method is based on the statistics of the phase of the electron exit wave function, which depend on the number of atoms traversed by the incident electron which itself is a function of the thickness of the object. The accuracy of this method has been checked numerically by the multislice method and compared with that based on the mean inner potential. (c) 2007 American Institute of Physics. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
American Institute of Physics |
Place of Publication |
New York, N.Y. |
Editor |
|
|
|
Language |
|
Wos |
000247305400033 |
Publication Date |
2007-06-14 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-6951; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
3.411 |
Times cited |
4 |
Open Access |
|
|
|
Notes |
Fwo |
Approved |
Most recent IF: 3.411; 2007 IF: 3.596 |
|
|
Call Number |
UA @ lucian @ c:irua:102671 |
Serial |
3158 |
|
Permanent link to this record |
|
|
|
|
Author |
Tsai, C.-Y.; Chang, Y.-C.; Lobato, I.; Van Dyck, D.; Chen, F.-R. |
|
|
Title |
Hollow Cone Electron Imaging for Single Particle 3D Reconstruction of Proteins |
Type |
A1 Journal article |
|
Year |
2016 |
Publication |
Scientific reports |
Abbreviated Journal |
Sci Rep-Uk |
|
|
Volume |
6 |
Issue |
6 |
Pages |
27701 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
The main bottlenecks for high-resolution biological imaging in electron microscopy are radiation sensitivity and low contrast. The phase contrast at low spatial frequencies can be enhanced by using a large defocus but this strongly reduces the resolution. Recently, phase plates have been developed to enhance the contrast at small defocus but electrical charging remains a problem. Single particle cryo-electron microscopy is mostly used to minimize the radiation damage and to enhance the resolution of the 3D reconstructions but it requires averaging images of a massive number of individual particles. Here we present a new route to achieve the same goals by hollow cone dark field imaging using thermal diffuse scattered electrons giving about a 4 times contrast increase as compared to bright field imaging. We demonstrate the 3D reconstruction of a stained GroEL particle can yield about 13.5 A resolution but using a strongly reduced number of images. |
|
|
Address |
Department of Engineering and System Science, Tsing-Hua University, HsinChu 300, Taiwan |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Wos |
000377670500001 |
Publication Date |
2016-06-13 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2045-2322 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
4.259 |
Times cited |
|
Open Access |
|
|
|
Notes |
D. Van Dyck acknowledges the financial support from the Fund for Scientific Research – Flanders (FWO) under Project nos. VF04812N and G.0188.08. F. R. Chen would like to thank the support from NSC 101-2221-E-007- 063-MY3 and MOST 104-2321-B-007-004. We are grateful for the use of the Tecnai F20 in the Cryo-EM Core Facility, Department of Academic Affairs and Instrument Service at Academia Sinica. |
Approved |
Most recent IF: 4.259 |
|
|
Call Number |
c:irua:134038 |
Serial |
4087 |
|
Permanent link to this record |
|
|
|
|
Author |
Ferroni, M.; Carotta, M.C.; Guidi, V.; Martinelli, G.; Ronconi, F.; Richard, O.; van Dyck, D.; van Landuyt, J. |
|
|
Title |
Structural characterization of Nb-TiO2 nanosized thick-films for gas sensing application |
Type |
P1 Proceeding |
|
Year |
2000 |
Publication |
Sensors and actuators : B : chemical |
Abbreviated Journal |
Sensor Actuat B-Chem |
|
|
Volume |
68 |
Issue |
1-3 |
Pages |
140-145 |
|
|
Keywords |
P1 Proceeding; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
Pure and Nb-doped TiO2 thick-films were prepared by screen-printing, starting from nanosized powders. Grain growth and crystalline phase modification occurred as consequence of firing at high temperature. It has been shown that niobium addition inhibits grain coarsening and hinders anatase-to-rutile phase transition. These semiconducting films exhibited n-type behavior, while Nb acted as donor-dopant. Gas measurements demonstrated that the films are suitable for CO or NO2 sensing. Microstructural characterization by electron microscopy and differential thermal analysis (DTA) highlights the dependence of gas-sensing behavior on film's properties. (C) 2000 Elsevier Science S.A. All rights reserved. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Lausanne |
Editor |
|
|
|
Language |
|
Wos |
000089218000022 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0925-4005; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
5.401 |
Times cited |
51 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 5.401; 2000 IF: 1.470 |
|
|
Call Number |
UA @ lucian @ c:irua:95167 |
Serial |
3223 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Tendeloo, G.; Schryvers, D.; van Dyck, D.; van Landuyt, J.; Amelinckx, S. |
|
|
Title |
Up close: Center for Electron Microscopy of Materials Science at the University of Antwerp |
Type |
A1 Journal article |
|
Year |
1994 |
Publication |
MRS bulletin |
Abbreviated Journal |
Mrs Bull |
|
|
Volume |
|
Issue |
|
Pages |
57-59 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Pittsburgh, Pa |
Editor |
|
|
|
Language |
|
Wos |
A1994PH66300015 |
Publication Date |
0000-00-00 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0883-7694 |
ISBN |
|
Additional Links |
UA library record; WoS full record; |
|
|
Impact Factor |
5.667 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ lucian @ c:irua:9996 |
Serial |
3821 |
|
Permanent link to this record |
|
|
|
|
Author |
Lobato Hoyos, I.P.; van Dyck, D. |
|
|
Title |
An accurate parameterization for scattering factors, electron densities and electrostatic potentials for neutral atoms that obey all physical constraints |
Type |
A1 Journal article |
|
Year |
2014 |
Publication |
Acta crystallographica: section A: foundations of crystallography |
Abbreviated Journal |
Acta Crystallogr A |
|
|
Volume |
70 |
Issue |
6 |
Pages |
636-649 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
An efficient procedure and computer program are outlined for fitting numerical X-ray and electron scattering factors with the correct inclusion of all physical constraints. The numerical electron scattering factors have been parameterized using five analytic non-relativistic hydrogen electron scattering factors as basis functions for 103 neutral atoms of the periodic table. The inclusion of the correct physical constraints in the electron scattering factor and its derived quantities allows the use of the new parameterization in different fields. In terms of quality of the fit, the proposed parameterization of the electron scattering factor is one order of magnitude better than the previous analytic fittings. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Copenhagen |
Editor |
|
|
|
Language |
|
Wos |
000344599300012 |
Publication Date |
2014-10-16 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2053-2733; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
5.725 |
Times cited |
19 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 5.725; 2014 IF: NA |
|
|
Call Number |
UA @ lucian @ c:irua:122103 |
Serial |
93 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Aert, S.; De Backer, A.; Martinez, G.T.; den Dekker, A.J.; Van Dyck, D.; Bals, S.; Van Tendeloo, G. |
|
|
Title |
Advanced electron crystallography through model-based imaging |
Type |
A1 Journal article |
|
Year |
2016 |
Publication |
IUCrJ |
Abbreviated Journal |
Iucrj |
|
|
Volume |
3 |
Issue |
3 |
Pages |
71-83 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab; Engineering Management (ENM) |
|
|
Abstract |
The increasing need for precise determination of the atomic arrangement of non-periodic structures in materials design and the control of nanostructures explains the growing interest in quantitative transmission electron microscopy. The aim is to extract precise and accurate numbers for unknown structure parameters including atomic positions, chemical concentrations and atomic numbers. For this purpose, statistical parameter estimation theory has been shown to provide reliable results. In this theory, observations are considered purely as data planes, from which structure parameters have to be determined using a parametric model describing the images. As such, the positions of atom columns can be measured with a precision of the order of a few picometres, even though the resolution of the electron microscope is still one or two orders of magnitude larger. Moreover, small differences in average atomic number, which cannot be distinguished visually, can be quantified using high-angle annular dark-field scanning transmission electron microscopy images. In addition, this theory allows one to measure compositional changes at interfaces, to count atoms with single-atom sensitivity, and to reconstruct atomic structures in three dimensions. This feature article brings the reader up to date, summarizing the underlying theory and highlighting some of the recent applications of quantitative model-based transmisson electron microscopy. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000368590900010 |
Publication Date |
2015-11-13 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2052-2525; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
5.793 |
Times cited |
30 |
Open Access |
OpenAccess |
|
|
Notes |
The authors gratefully acknowledge the Research Foundation Flanders (FWO, Belgium) for funding and for a PhD grant to ADB. The research leading to these results has received funding from the European Union 7th Framework Program (FP7/20072013) under grant agreement No. 312483 (ESTEEM2). SB and GVT acknowledge the European Research Council under the 7th Framework Program (FP7), ERC grant No. 335078 – COLOURATOMS and ERC grant No. 246791 – COUNTATOMS.; esteem2jra2; ECASSara; (ROMEO:green; preprint:; postprint:can ; pdfversion:can); |
Approved |
Most recent IF: 5.793 |
|
|
Call Number |
c:irua:129589 c:irua:129589 |
Serial |
3965 |
|
Permanent link to this record |
|
|
|
|
Author |
Zhang, X.B.; Van Tendeloo, G.; van Landuyt, J.; van Dyck, D.; Briers, J.; Bao, Y.; Geise, H.J. |
|
|
Title |
An electron microscopic study of highly oriented undoped and FeCl3-doped poly (p-phenylenevinylene) |
Type |
A1 Journal article |
|
Year |
1996 |
Publication |
Macromolecules |
Abbreviated Journal |
Macromolecules |
|
|
Volume |
29 |
Issue |
5 |
Pages |
1554-1561 |
|
|
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Washington, D.C. |
Editor |
|
|
|
Language |
|
Wos |
A1996TY13900024 |
Publication Date |
2002-07-26 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0024-9297;1520-5835; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
5.8 |
Times cited |
10 |
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ lucian @ c:irua:15452 |
Serial |
939 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Tendeloo, G.; Bals, S.; Van Aert, S.; Verbeeck, J.; van Dyck, D. |
|
|
Title |
Advanced electron microscopy for advanced materials |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
Advanced materials |
Abbreviated Journal |
Adv Mater |
|
|
Volume |
24 |
Issue |
42 |
Pages |
5655-5675 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT); Vision lab |
|
|
Abstract |
The idea of this Review is to introduce newly developed possibilities of advanced electron microscopy to the materials science community. Over the last decade, electron microscopy has evolved into a full analytical tool, able to provide atomic scale information on the position, nature, and even the valency atoms. This information is classically obtained in two dimensions (2D), but can now also be obtained in 3D. We show examples of applications in the field of nanoparticles and interfaces. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Weinheim |
Editor |
|
|
|
Language |
|
Wos |
000310602200001 |
Publication Date |
2012-08-21 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0935-9648; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
19.791 |
Times cited |
107 |
Open Access |
|
|
|
Notes |
This work was supported by funding from the European Research Council under the 7th Framework Program (FP7), ERC grant No 246791 – COUNTATOMS. J.V. Acknowledges funding from the European Research Council under the 7th Framework Program (FP7), ERC Starting Grant 278510 VORTEX. The authors gratefully acknowledge funding from the Research Foundation Flanders (FWO, Belgium). The Qu-Ant-EM microscope was partly funded by the Hercules Fund from the Flemish Government. We thank Rafal Dunin-Borkowski for providing Figure 5d. The authors would like to thank the colleagues who have contributed to this work over the years, including K.J. Batenburg, R. Erni, B. Goris, F. Leroux, H. Lichte, A. Lubk, B. Partoens, M. D. Rossell, P. Schattschneider, B. Schoeters, D. Schryvers, H. Tan, H. Tian, S. Turner, M. van Huis. ECASJO_; |
Approved |
Most recent IF: 19.791; 2012 IF: 14.829 |
|
|
Call Number |
UA @ lucian @ c:irua:100470UA @ admin @ c:irua:100470 |
Serial |
70 |
|
Permanent link to this record |