Records |
Author |
Van Aert, S.; de Backer, A.; Martinez, G.T.; Goris, B.; Bals, S.; Van Tendeloo, G.; Rosenauer, A. |
Title |
Procedure to count atoms with trustworthy single-atom sensitivity |
Type |
A1 Journal article |
Year |
2013 |
Publication |
Physical review : B : condensed matter and materials physics |
Abbreviated Journal |
Phys Rev B |
Volume |
87 |
Issue |
6 |
Pages |
064107-6 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
We report a method to reliably count the number of atoms from high-angle annular dark field scanning transmission electron microscopy images. A model-based analysis of the experimental images is used to measure scattering cross sections at the atomic level. The high sensitivity of these measurements in combination with a thorough statistical analysis enables us to count atoms with single-atom sensitivity. The validity of the results is confirmed by means of detailed image simulations. We will show that the method can be applied to nanocrystals of arbitrary shape, size, and atom type without the need for a priori knowledge about the atomic structure. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000315144700006 |
Publication Date |
2013-02-20 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1098-0121;1550-235X; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
3.836 |
Times cited |
106 |
Open Access |
|
Notes |
FWO; 262348 ESMI; 312483 ESTEEM2;246791 COUNTATOMS; Hercules 3; esteem2_jra2 |
Approved |
Most recent IF: 3.836; 2013 IF: 3.664 |
Call Number |
UA @ lucian @ c:irua:105674 |
Serial |
2718 |
Permanent link to this record |
|
|
|
Author |
Attri, P.; Kaushik, N.K.; Kaushik, N.; Hammerschmid, D.; Privat-Maldonado, A.; De Backer, J.; Shiratani, M.; Choi, E.H.; Bogaerts, A. |
Title |
Plasma treatment causes structural modifications in lysozyme, and increases cytotoxicity towards cancer cells |
Type |
A1 Journal Article |
Year |
2021 |
Publication |
International Journal Of Biological Macromolecules |
Abbreviated Journal |
Int J Biol Macromol |
Volume |
182 |
Issue |
|
Pages |
1724-1736 |
Keywords |
A1 Journal Article; Lysozyme; Cold atmospheric plasma; Cancer cell death; Plasma, laser ablation and surface modeling Antwerp (PLASMANT) ; |
Abstract |
Bacterial and mammalian proteins, such as lysozyme, are gaining increasing interest as anticancer drugs. This study aims to modify the lysozyme structure using cold atmospheric plasma to boost its cancer cell killing effect. We investigated the structure at acidic and neutral pH using various experimental techniques (circular dichroism, fluorescence, and mass spectrometry) and molecular dynamics simulations. The controlled structural modification of lysozyme at neutral pH enhances its activity, while the activity was lost at acidic pH at the same treatment conditions. Indeed, a larger number of amino acids were oxidized at acidic pH after plasma treatment, which results in a greater distortion of the lysozyme structure, whereas only limited structural changes were observed in lysozyme after plasma treatment at neutral pH. We found that the plasma-treated lysozyme significantly induced apoptosis to the cancer cells. Our results reveal that plasma-treated lysozyme could have potential as a new cancer cell killing drug. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000675794700005 |
Publication Date |
2021-05-27 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0141-8130 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
3.671 |
Times cited |
|
Open Access |
OpenAccess |
Notes |
Japan Society for the Promotion of Science; We gratefully acknowledge the European H2020 Marie SkłodowskaCurie Actions Individual Fellowship “Anticancer-PAM” within Horizon2020 (grant number 743546). This work was also supported by JSPS-KAKENHI grant number 20K14454. NK thanks to National Research Foundation of Korea under Ministry of Science and ICT (NRF2021R1C1C1013875) of Korean Government. The computational work was carried out using the Turing HPC infrastructure at the CalcUA core facility of the Universiteit Antwerpen (UA), a division of the Flemish Supercomputer Center VSC, funded by the Hercules Foundation, the Flemish Government (department EWI) and the UA. |
Approved |
Most recent IF: 3.671 |
Call Number |
PLASMANT @ plasmant @c:irua:178813 |
Serial |
6792 |
Permanent link to this record |
|
|
|
Author |
Gonnissen, J.; de Backer, A.; den Dekker, A.J.; Martinez, G.T.; Rosenauer, A.; Sijbers, J.; Van Aert, S. |
Title |
Optimal experimental design for the detection of light atoms from high-resolution scanning transmission electron microscopy images |
Type |
A1 Journal article |
Year |
2014 |
Publication |
Applied physics letters |
Abbreviated Journal |
Appl Phys Lett |
Volume |
105 |
Issue |
6 |
Pages |
063116 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
Abstract |
We report an innovative method to explore the optimal experimental settings to detect light atoms from scanning transmission electron microscopy (STEM) images. Since light elements play a key role in many technologically important materials, such as lithium-battery devices or hydrogen storage applications, much effort has been made to optimize the STEM technique in order to detect light elements. Therefore, classical performance criteria, such as contrast or signal-to-noise ratio, are often discussed hereby aiming at improvements of the direct visual interpretability. However, when images are interpreted quantitatively, one needs an alternative criterion, which we derive based on statistical detection theory. Using realistic simulations of technologically important materials, we demonstrate the benefits of the proposed method and compare the results with existing approaches. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
American Institute of Physics |
Place of Publication |
New York, N.Y. |
Editor |
|
Language |
|
Wos |
000341188700073 |
Publication Date |
2014-08-14 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0003-6951;1077-3118; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
3.411 |
Times cited |
12 |
Open Access |
|
Notes |
FWO (G.0393.11; G.0064.10; and G.0374.13); European Union Seventh Framework Programme [FP7/2007-2013] under Grant Agreement No. 312483 (ESTEEM2); esteem2_jra2 |
Approved |
Most recent IF: 3.411; 2014 IF: 3.302 |
Call Number |
UA @ lucian @ c:irua:118333 |
Serial |
2482 |
Permanent link to this record |
|
|
|
Author |
Van Holsbeke, C.; Vos, W.; van Hoorenbeeck, K.; Boudewyns, A.; Salgado, R.; Verdonck, P.R.; Ramet, J.; de Backer, J.; De Backer, W.; Verhulst, S.L. |
Title |
Functional respiratory imaging as a tool to assess upper airway patency in children with obstructive sleep apnea |
Type |
A1 Journal article |
Year |
2013 |
Publication |
Sleep Medicine |
Abbreviated Journal |
Sleep Med |
Volume |
14 |
Issue |
5 |
Pages |
433-439 |
Keywords |
A1 Journal article; Condensed Matter Theory (CMT); Laboratory Experimental Medicine and Pediatrics (LEMP) |
Abstract |
Objective: We aim to investigate if anatomical and functional properties of the upper airway using computerized 3D models derived from computed tomography (CT) scans better predict obstructive sleep apnea (OSA) severity than standard clinical markers. Methods: Consecutive children with suspected OSA underwent polysomnography, clinical assessment of upper airway patency, and a CT scan while awake. A three-dimensional (3D) reconstruction of the pharyngeal airway was built from these images, and computational fluid dynamics modeling of low inspiratory flow was performed using open-source software. Results: Thirty-three children were included (23 boys; mean age, was 6.0 +/- 3.2 y). OSA was diagnosed in 23 patients. Children with OSA had a significantly lower volume of the overlap region between tonsils and the adenoids (median volume, 1408 mm compared to 2173 mm; p = 0.04), a lower mean cross-sectional area at this location (median volume, 69.3 mm(2) compared to 114.3 mm(2); p = 0.04), and a lower minimal cross-sectional area (median volume, 17.9 mm(2) compared to 25.9 mm(2); p = 0.05). Various significant correlations were found between several imaging parameters and the severity of OSA, most pronounced for upper airway conductance (r = -0.46) (p < 0.01) for correlation between upper airway conductance and the apnea-hypopnea index. No differences or significant correlations were observed with clinical parameters of upper airway patency. Preliminary data after treatment showed that none of the patients with residual OSA had their smallest cross-sectional area located in segment 3, and this frequency was significantly lower than in their peers whose sleep study normalized (64%; p = 0.05). Conclusion: Functional imaging parameters are highly correlated with OSA severity and are a more powerful correlate than clinical scores of upper airway patency. Preliminary data also showed that we could identify differences in the upper airway of those subjects who did not benefit from a local upper airway treatment. (c) 2013 Elsevier B.V. All rights reserved. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000318612100009 |
Publication Date |
2013-03-07 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1389-9457; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
3.391 |
Times cited |
18 |
Open Access |
|
Notes |
; ; |
Approved |
Most recent IF: 3.391; 2013 IF: 3.100 |
Call Number |
UA @ lucian @ c:irua:109015 |
Serial |
1302 |
Permanent link to this record |
|
|
|
Author |
Klingstedt, M.; Sundberg, M.; Eriksson, L.; Haigh, S.; Kirkland, A.; Grüner, D.; de Backer, A.; Van Aert, S.; Tarasaki, O. |
Title |
Exit wave reconstruction from focal series of HRTEM images, single crystal XRD and total energy studies on SbxWO3+y (x\sim0.11) |
Type |
A1 Journal article |
Year |
2012 |
Publication |
Zeitschrift für Kristallographie |
Abbreviated Journal |
Z Krist-Cryst Mater |
Volume |
227 |
Issue |
6 |
Pages |
341-349 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
A new tungsten bronze in the SbWO system has been prepared in a solid state reaction from Sb2O3, WO3 and W metal powder. The average structure was determined by single crystal X-ray diffraction. SbxWO3+y (x ∼ 0.11) crystallizes in the orthorhombic space group Pm21n (no. 31), a = 27.8135(9) Å, b = 7.3659(2) Å and c = 3.8672(1) Å. The structure belongs to the (n)-ITB class of intergrowth tungsten bronzes. It contains slabs of hexagonal channels formed by six WO6 octahedra. These slabs are separated by three layers of WO6 octahedra that are arranged in a WO3-type fashion. The WO6 octahedra share all vertices to build up a three-dimensional framework. The hexagonal channels are filled with Sb atoms to ∼80% and additional O atoms. The atoms are shifted out of the center of the channels. Exit-wave reconstruction of focal series of high resolution-transmission-electron-microscope (HRTEM) images combined with statistical paramäeter estimation techniques allowed to study local ordering in the channels. Sb atoms in neighbouring channels tend to be displaced in the same direction, which is in agreement with total energy calculations on ordered structure models, but the ratio of the occupation of the two possible Sb sites varies from channel to channel. The structure of SbxWO3+y exhibits pronounced local modulations. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
München |
Editor |
|
Language |
|
Wos |
000307314200003 |
Publication Date |
2012-06-06 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
2194-4946; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
3.179 |
Times cited |
4 |
Open Access |
|
Notes |
Fwo; Esteem 026019 |
Approved |
Most recent IF: 3.179; 2012 IF: NA |
Call Number |
UA @ lucian @ c:irua:101218 |
Serial |
1131 |
Permanent link to this record |
|
|
|
Author |
de Backer, J.; Vos, W.; Van Holsbeke, C.; Vinchurkar, S.; Claes, R.; Parizel, P.M.; de Backer, W. |
Title |
Effect of high-dose N-acetylcysteine on airway geometry, inflammation, and oxidative stress in COPD patients |
Type |
A1 Journal article |
Year |
2013 |
Publication |
International Journal Of Chronic Obstructive Pulmonary Disease |
Abbreviated Journal |
Int J Chronic Obstr |
Volume |
8 |
Issue |
|
Pages |
569-579 |
Keywords |
A1 Journal article; Biophysics and Biomedical Physics; Condensed Matter Theory (CMT); Antwerp Surgical Training, Anatomy and Research Centre (ASTARC); Laboratory Experimental Medicine and Pediatrics (LEMP) |
Abstract |
Background: Previous studies have demonstrated the potential beneficial effect of N-acetylcysteine (NAC) in chronic obstructive pulmonary disease (COPD). However, the required dose and responder phenotype remain unclear. The current study investigated the effect of high-dose NAC on airway geometry, inflammation, and oxidative stress in COPD patients. Novel functional respiratory imaging methods combining multislice computed tomography images and computer-based flow simulations were used with high sensitivity for detecting changes induced by the therapy. Methods: Twelve patients with Global Initiative for Chronic Obstructive Lung Disease stage II COPD were randomized to receive NAC 1800 mg or placebo daily for 3 months and were then crossed over to the alternative treatment for a further 3 months. Results: Significant correlations were found between image-based resistance values and glutathione levels after treatment with NAC (P = 0.011) and glutathione peroxidase at baseline (P = 0.036). Image-based resistance values appeared to be a good predictor for glutathione peroxidase levels after NAC (P = 0.02), changes in glutathione peroxidase levels (P = 0.035), and reduction in lobar functional residual capacity levels (P = 0.00084). In the limited set of responders to NAC therapy, the changes in airway resistance were in the same order as changes induced by budesonide/formoterol. Conclusion: A combination of glutathione, glutathione peroxidase, and imaging parameters could potentially be used to phenotype COPD patients who would benefit from addition of NAC to their current therapy. The findings of this small pilot study need to be confirmed in a larger pivotal trial. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000327537300001 |
Publication Date |
2013-11-21 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1178-2005; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
3.157 |
Times cited |
21 |
Open Access |
|
Notes |
; JDB is a founder/shareholder of FluidDA NV, Kontich, Belgium. WV, SV, and CVH are employed by FluidDA NV, and WDB is the director of FluidDA NV. PMP and RC have no conflicts of interest to report. The study was supported by Zambon SpA, Bresso, Italy. ; |
Approved |
Most recent IF: 3.157; 2013 IF: NA |
Call Number |
UA @ lucian @ c:irua:112799 |
Serial |
813 |
Permanent link to this record |
|
|
|
Author |
De Backer, L.; Vos, W.; Dieriks, B.; Daems, D.; Verhulst, S.; Vinchurkar, S.; Ides, K.; de Backer, J.; Germonpré, P.; de Backer, W. |
Title |
The effects of long-term noninvasive ventilation in hypercapnic COPD patients : a randomized controlled pilot study |
Type |
A1 Journal article |
Year |
2011 |
Publication |
International journal of chronic obstructive pulmonary disease |
Abbreviated Journal |
Int J Chronic Obstr |
Volume |
6 |
Issue |
|
Pages |
615-624 |
Keywords |
A1 Journal article; Condensed Matter Theory (CMT); Laboratory Experimental Medicine and Pediatrics (LEMP) |
Abstract |
Introduction: Noninvasive ventilation (NIV) is a well-established treatment for acute-on-chronic respiratory failure in hypercapnic COPD patients. Less is known about the effects of a long-term treatment with NIV in hypercapnic COPD patients and about the factors that may predict response in terms of improved oxygenation and lowered CO2 retention.Methods: In this study, we randomized 15 patients to a routine pharmacological treatment (n = 5, age 66 [standard deviation ± 6] years, FEV1 30.5 [±5.1] %pred, PaO2 65 [±6] mmHg, PaCO2 52.4 [±6.0] mmHg) or to a routine treatment and NIV (using the Synchrony BiPAP device [Respironics, Inc, Murrsville, PA]) (n = 10, age 65 [±7] years, FEV1 29.5 [±9.0] %pred, PaO2 59 [±13] mmHg, PaCO2 55.4 [±7.7] mmHg) for 6 months. We looked at arterial blood gasses, lung function parameters and performed a low-dose computed tomography of the thorax, which was later used for segmentation (providing lobe and airway volumes, iVlobe and iVaw) and post-processing with computer methods (providing airway resistance, iRaw) giving overall a functional image of the separate airways and lobes.Results: In both groups there was a nonsignificant change in FEV1 (NIV group 29.5 [9.0] to 38.5 [14.6] %pred, control group 30.5 [5.1] to 36.8 [8.7] mmHg). PaCO2 dropped significantly only in the NIV group (NIV: 55.4 [7.7] → 44.5 [4.70], P = 0.0076; control: 52.4 [6.0] → 47.6 [8.2], NS). Patients actively treated with NIV developed a more inhomogeneous redistribution of mass flow than control patients. Subsequent analysis indicated that in NIV-treated patients that improve their blood gases, mass flow was also redistributed towards areas with higher vessel density and less emphysema, indicating that flow was redistributed towards areas with better perfusion. There was a highly significant correlation between the % increase in mass flow towards lobes with a blood vessel density of >9% and the increase in PaO2. Improved ventilation–perfusion match and recruitment of previously occluded small airways can explain the improvement in blood gases.Conclusion: We can conclude that in hypercapnic COPD patients treated with long-term NIV over 6 months, a mass flow redistribution occurs, providing a better ventilation–perfusion match and hence better blood gases and lung function. Control patients improve homogeneously in iVaw and iRaw, without improvement in gas exchange since there is no improved ventilation/perfusion ratio or increased alveolar ventilation. These differences in response can be detected through functional imaging, which gives a more detailed report on regional lung volumes and resistances than classical lung function tests do. Possibly only patients with localized small airway disease are good candidates for long-term NIV treatment. To confirm this and to see if better arterial blood gases also lead to better health related quality of life and longer survival, we have to study a larger population. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000208709800066 |
Publication Date |
2011-11-18 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1178-2005; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
3.157 |
Times cited |
28 |
Open Access |
|
Notes |
; ; |
Approved |
Most recent IF: 3.157; 2011 IF: NA |
Call Number |
UA @ lucian @ c:irua:93164 |
Serial |
866 |
Permanent link to this record |
|
|
|
Author |
De Backer, L.A.; Vos, W.G.; Salgado, R.; de Backer, J.W.; Devolder, A.; Verhulst, S.L.; Claes, R.; Germonpré, P.R.; de Backer, W.A. |
Title |
Functional imaging using computer methods to compare the effect of salbutamol and ipratropium bromide in patient-specific airway models of COPD |
Type |
A1 Journal article |
Year |
2011 |
Publication |
International journal of chronic obstructive pulmonary disease |
Abbreviated Journal |
Int J Chronic Obstr |
Volume |
6 |
Issue |
|
Pages |
637-646 |
Keywords |
A1 Journal article; Condensed Matter Theory (CMT); Vision lab; Laboratory Experimental Medicine and Pediatrics (LEMP) |
Abstract |
Background: Salbutamol and ipratropium bromide improve lung function in patients with chronic obstructive pulmonary disease (COPD). However, their bronchodilating effect has not yet been compared in the central and distal airways. Functional imaging using computational fluid dynamics offers the possibility of making such a comparison. The objective of this study was to assess the effects of salbutamol and ipratropium bromide on the geometry and computational fluid dynamics-based resistance of the central and distal airways.Methods: Five patients with Global Initiative for Chronic Obstructive Lung Disease Stage III COPD were randomized to a single dose of salbutamol or ipratropium bromide in a crossover manner with a 1-week interval between treatments. Patients underwent lung function testing and a multislice computed tomography scan of the thorax that was used for functional imaging. Two hours after dosing, the patients again underwent lung function tests and repeat computed tomography.Results: Lung function parameters, including forced expiratory volume in 1 second, vital capacity, overall airway resistance, and specific airway resistance, changed significantly after administration of each product. On functional imaging, the bronchodilating effect was greater in the distal airways, with a corresponding drop in airway resistance, compared with the central airways. Salbutamol and ipratropium bromide were equally effective at first glance when looking at lung function tests, but when viewed in more detail with functional imaging, hyporesponsiveness could be shown for salbutamol in one patient. Salbutamol was more effective in the other patients.Conclusion: This pilot study gives an innovative insight into the modes of action of salbutamol and ipratropium bromide in patients with COPD, using the new techniques of functional imaging and computational fluid dynamics. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000208709800068 |
Publication Date |
2011-11-28 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1178-2005; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
3.157 |
Times cited |
25 |
Open Access |
|
Notes |
; ; |
Approved |
Most recent IF: 3.157; 2011 IF: NA |
Call Number |
UA @ lucian @ c:irua:93165 |
Serial |
1300 |
Permanent link to this record |
|
|
|
Author |
Vermeylen, S.; De Waele, J.; Vanuytsel, S.; De Backer, J.; Van der Paal, J.; Ramakers, M.; Leyssens, K.; Marcq, E.; Van Audenaerde, J.; L. J. Smits, E.; Dewilde, S.; Bogaerts, A. |
Title |
Cold atmospheric plasma treatment of melanoma and glioblastoma cancer cells |
Type |
A1 Journal article |
Year |
2016 |
Publication |
Plasma processes and polymers |
Abbreviated Journal |
Plasma Process Polym |
Volume |
13 |
Issue |
13 |
Pages |
1195-1205 |
Keywords |
A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT) |
Abstract |
In this paper, two types of melanoma and glioblastoma cancer cell lines are treated with cold atmospheric plasma to assess the effect of several parameters on the cell viability. The cell viability decreases with treatment duration and time until analysis in all cell lines with varying sensitivity. The majority of dead cells stains both AnnexinV (AnnV) and propidium iodide, indicating that the plasma-treated non-viable cells are mostly late apoptotic or necrotic. Genetic mutations might be involved in the response to plasma. Comparing the effects of two gas mixtures, as well as indirect plasma-activated medium versus direct treatment, gives different results per cell line. In conclusion, this study confirms the potential of plasma for cancer therapy and emphasizes the influence of experimental parameters on therapeutic outcome. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000393131600007 |
Publication Date |
2016-10-31 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1612-8850 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.846 |
Times cited |
26 |
Open Access |
|
Notes |
The authors acknowledge the University of Antwerp for providing research funds. The authors are very grateful to V. Schulz-von der Gathen and J. Benedikt (Bochum University) for providing the COST RF plasma jet. The authors would also like to thank Eva Santermans (University of Hasselt) for statistical advice. J. De Waele, J. Van Audenaerde and J. Van der Paal are research fellows of the Research Foundation Flanders (fellowship numbers: 1121016N, 1S32316N and 11U5416N), E. Marcq of Flanders Innovation & Entrepreneurship (fellowship number: 141433). |
Approved |
Most recent IF: 2.846 |
Call Number |
PLASMANT @ plasmant @ c:irua:138722 |
Serial |
4328 |
Permanent link to this record |
|
|
|
Author |
van den Broek, W.; Verbeeck, J.; de Backer, S.; Scheunders, P.; Schryvers, D. |
Title |
Acquisition of the EELS data cube by tomographic reconstruction |
Type |
A1 Journal article |
Year |
2006 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
106 |
Issue |
4/5 |
Pages |
269-276 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
Abstract |
Energy filtered TEM, EFTEM, provides three-dimensional data, two spatial and one spectral dimension. We propose to acquire these data by measuring a series of images with a defocused energy filter. It will be shown that each image is a projection of the data on the detector and that reconstruction of the data out of a sufficient number of such projections using a tomographic reconstruction algorithm is possible. This technique uses only a fraction of the electron dose an energy filtered series (EFS) needs for the same spectral and spatial resolution and the same mean signal-to-noise ratio. (c) 2005 Elsevier B.V. All rights reserved. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000236042300003 |
Publication Date |
2005-11-30 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
6 |
Open Access |
|
Notes |
|
Approved |
Most recent IF: 2.843; 2006 IF: 1.706 |
Call Number |
UA @ lucian @ c:irua:56910UA @ admin @ c:irua:56910 |
Serial |
55 |
Permanent link to this record |
|
|
|
Author |
de Backer, A.; Martinez, G.T.; Rosenauer, A.; Van Aert, S. |
Title |
Atom counting in HAADF STEM using a statistical model-based approach : methodology, possibilities, and inherent limitations |
Type |
A1 Journal article |
Year |
2013 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
134 |
Issue |
|
Pages |
23-33 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
In the present paper, a statistical model-based method to count the number of atoms of monotype crystalline nanostructures from high resolution high-angle annular dark-field (HAADF) scanning transmission electron microscopy (STEM) images is discussed in detail together with a thorough study on the possibilities and inherent limitations. In order to count the number of atoms, it is assumed that the total scattered intensity scales with the number of atoms per atom column. These intensities are quantitatively determined using model-based statistical parameter estimation theory. The distribution describing the probability that intensity values are generated by atomic columns containing a specific number of atoms is inferred on the basis of the experimental scattered intensities. Finally, the number of atoms per atom column is quantified using this estimated probability distribution. The number of atom columns available in the observed STEM image, the number of components in the estimated probability distribution, the width of the components of the probability distribution, and the typical shape of a criterion to assess the number of components in the probability distribution directly affect the accuracy and precision with which the number of atoms in a particular atom column can be estimated. It is shown that single atom sensitivity is feasible taking the latter aspects into consideration. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000324474900005 |
Publication Date |
2013-05-17 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
48 |
Open Access |
|
Notes |
FWO; Esteem2; FP 2007-2013; esteem2_jra2 |
Approved |
Most recent IF: 2.843; 2013 IF: 2.745 |
Call Number |
UA @ lucian @ c:irua:109916 |
Serial |
162 |
Permanent link to this record |
|
|
|
Author |
de Backer, A.; Martinez, G.T.; MacArthur, K.E.; Jones, L.; Béché, A.; Nellist, P.D.; Van Aert, S. |
Title |
Dose limited reliability of quantitative annular dark field scanning transmission electron microscopy for nano-particle atom-counting |
Type |
A1 Journal article |
Year |
2015 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
151 |
Issue |
151 |
Pages |
56-61 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
Quantitative annular dark field scanning transmission electron microscopy (ADF STEM) has become a powerful technique to characterise nano-particles on an atomic scale. Because of their limited size and beam sensitivity, the atomic structure of such particles may become extremely challenging to determine. Therefore keeping the incoming electron dose to a minimum is important. However, this may reduce the reliability of quantitative ADF STEM which will here be demonstrated for nano-particle atom-counting. Based on experimental ADF STEM images of a real industrial catalyst, we discuss the limits for counting the number of atoms in a projected atomic column with single atom sensitivity. We diagnose these limits by combining a thorough statistical method and detailed image simulations. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000351237800008 |
Publication Date |
2014-12-03 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
29 |
Open Access |
|
Notes |
312483 Esteem2; 278510 Vortex; Fwo G039311; G006410; G037413; esteem2ta; ECASJO; |
Approved |
Most recent IF: 2.843; 2015 IF: 2.436 |
Call Number |
c:irua:123927 c:irua:123927 |
Serial |
753 |
Permanent link to this record |
|
|
|
Author |
den Dekker, A.J.; Gonnissen, J.; de Backer, A.; Sijbers, J.; Van Aert, S. |
Title |
Estimation of unknown structure parameters from high-resolution (S)TEM images : what are the limits? |
Type |
A1 Journal article |
Year |
2013 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
134 |
Issue |
|
Pages |
34-43 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
Abstract |
Statistical parameter estimation theory is proposed as a quantitative method to measure unknown structure parameters from electron microscopy images. Images are then purely considered as data planes from which structure parameters have to be determined as accurately and precisely as possible using a parametric statistical model of the observations. For this purpose, an efficient algorithm is proposed for the estimation of atomic column positions and intensities from high angle annular dark field (HAADF) scanning transmission electron microscopy (STEM) images. Furthermore, the so-called CramérRao lower bound (CRLB) is reviewed to determine the limits to the precision with which continuous parameters such as atomic column positions and intensities can be estimated. Since this lower bound can only be derived for continuous parameters, alternative measures using the principles of detection theory are introduced for problems concerning the estimation of discrete parameters such as atomic numbers. An experimental case study is presented to show the practical use of these measures for the optimization of the experiment design if the purpose is to decide between the presence of specific atom types using STEM images. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000324474900006 |
Publication Date |
2013-06-01 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
31 |
Open Access |
|
Notes |
FWO; FP 2007-2013; Esteem2; esteem2_jra2 |
Approved |
Most recent IF: 2.843; 2013 IF: 2.745 |
Call Number |
UA @ lucian @ c:irua:109240 |
Serial |
1083 |
Permanent link to this record |
|
|
|
Author |
de Backer, A.; Van Aert, S.; van Dyck, D. |
Title |
High precision measurements of atom column positions using model-based exit wave reconstruction |
Type |
A1 Journal article |
Year |
2011 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
111 |
Issue |
9/10 |
Pages |
1475-1482 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
Abstract |
In this paper, it has been investigated how to measure atom column positions as accurately and precisely as possible using a focal series of images. In theory, it is expected that the precision would considerably improve using a maximum likelihood estimator based on the full series of focal images. As such, the theoretical lower bound on the variances of the unknown atom column positions can be attained. However, this approach is numerically demanding. Therefore, maximum likelihood estimation has been compared with the results obtained by fitting a model to a reconstructed exit wave rather than to the full series of focal images. Hence, a real space model-based exit wave reconstruction technique based on the channelling theory is introduced. Simulations show that the reconstructed complex exit wave contains the same amount of information concerning the atom column positions as the full series of focal images. Only for thin samples, which act as weak phase objects, this information can be retrieved from the phase of the reconstructed complex exit wave. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000300461200004 |
Publication Date |
2011-07-28 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
8 |
Open Access |
|
Notes |
Fwo |
Approved |
Most recent IF: 2.843; 2011 IF: 2.471 |
Call Number |
UA @ lucian @ c:irua:91879 |
Serial |
1438 |
Permanent link to this record |
|
|
|
Author |
de Backer, A.; De wael, A.; Gonnissen, J.; Van Aert, S. |
Title |
Optimal experimental design for nano-particle atom-counting from high-resolution STEM images |
Type |
A1 Journal article |
Year |
2015 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
151 |
Issue |
151 |
Pages |
46-55 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
In the present paper, the principles of detection theory are used to quantify the probability of error for atom-counting from high resolution scanning transmission electron microscopy (HR STEM) images. Binary and multiple hypothesis testing have been investigated in order to determine the limits to the precision with which the number of atoms in a projected atomic column can be estimated. The probability of error has been calculated when using STEM images, scattering cross-sections or peak intensities as a criterion to count atoms. Based on this analysis, we conclude that scattering cross-sections perform almost equally well as images and perform better than peak intensities. Furthermore, the optimal STEM detector design can be derived for atom-counting using the expression for the probability of error. We show that for very thin objects LAADF is optimal and that for thicker objects the optimal inner detector angle increases. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000351237800007 |
Publication Date |
2014-11-11 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
24 |
Open Access |
|
Notes |
312483 Esteem2; Fwo G039311; G037413; esteem2_jra2 |
Approved |
Most recent IF: 2.843; 2015 IF: 2.436 |
Call Number |
c:irua:123926 c:irua:123926 |
Serial |
2481 |
Permanent link to this record |
|
|
|
Author |
Martinez, G.T.; Rosenauer, A.; de Backer, A.; Verbeeck, J.; Van Aert, S. |
Title |
Quantitative composition determination at the atomic level using model-based high-angle annular dark field scanning transmission electron microscopy |
Type |
A1 Journal article |
Year |
2014 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
137 |
Issue |
|
Pages |
12-19 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
High angle annular dark field scanning transmission electron microscopy (HAADF STEM) images provide sample information which is sensitive to the chemical composition. The image intensities indeed scale with the mean atomic number Z. To some extent, chemically different atomic column types can therefore be visually distinguished. However, in order to quantify the atomic column composition with high accuracy and precision, model-based methods are necessary. Therefore, an empirical incoherent parametric imaging model can be used of which the unknown parameters are determined using statistical parameter estimation theory (Van Aert et al., 2009, [1]). In this paper, it will be shown how this method can be combined with frozen lattice multislice simulations in order to evolve from a relative toward an absolute quantification of the composition of single atomic columns with mixed atom types. Furthermore, the validity of the model assumptions are explored and discussed. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000331092200003 |
Publication Date |
2013-11-09 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
74 |
Open Access |
|
Notes |
FWO; FP7; ERC Countatoms; ESTEEM2; esteem2_ta |
Approved |
Most recent IF: 2.843; 2014 IF: 2.436 |
Call Number |
UA @ lucian @ c:irua:111579UA @ admin @ c:irua:111579 |
Serial |
2749 |
Permanent link to this record |
|
|
|
Author |
Martinez, G.T.; Jones, L.; de Backer, A.; Béché, A.; Verbeeck, J.; Van Aert, S.; Nellist, P.D. |
Title |
Quantitative STEM normalisation : the importance of the electron flux |
Type |
A1 Journal article |
Year |
2015 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
159 |
Issue |
159 |
Pages |
46-58 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
Annular dark-field (ADF) scanning transmission electron microscopy (STEM) has become widely used in quantitative studies based on the opportunity to directly compare experimental and simulated images. This comparison merely requires the experimental data to be normalised and expressed in units of fractional beam-current. However, inhomogeneities in the response of electron detectors can complicate this normalisation. The quantification procedure becomes both experiment and instrument specific, requiring new simulations for the particular response of each instrument's detector, and for every camera-length used. This not only impedes the comparison between different instruments and research groups, but can also be computationally very time consuming. Furthermore, not all image simulation methods allow for the inclusion of an inhomogeneous detector response. In this work, we propose an alternative method for normalising experimental data in order to compare these with simulations that consider a homogeneous detector response. To achieve this, we determine the electron flux distribution reaching the detector by means of a camera-length series or a so-called atomic column cross-section averaged convergent beam electron diffraction (XSACBED) pattern. The result is then used to determine the relative weighting of the detector response. Here we show that the results obtained by this new electron flux weighted (EFW) method are comparable to the currently used method, while considerably simplifying the needed simulation libraries. The proposed method also allows one to obtain a metric that describes the quality of the detector response in comparison with the ideal detector response. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000366220000006 |
Publication Date |
2015-08-01 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
27 |
Open Access |
|
Notes |
246791 Countatoms; 278510 Vortex; 312483 Esteem2; Fwo G036815; G036915; G037413; G004413; esteem2ta ECASJO; |
Approved |
Most recent IF: 2.843; 2015 IF: 2.436 |
Call Number |
c:irua:127293 c:irua:127293UA @ admin @ c:irua:127293 |
Serial |
2762 |
Permanent link to this record |
|
|
|
Author |
van den Broek, W.; Verbeeck, J.; Schryvers, D.; de Backer, S.; Scheunders, P. |
Title |
Tomographic spectroscopic imaging; an experimental proof of concept |
Type |
A1 Journal article |
Year |
2009 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
109 |
Issue |
4 |
Pages |
296-303 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
Abstract |
Recording the electron energy loss spectroscopy data cube with a series of energy filtered images is a dose inefficient process because the energy slit blocks most of the electrons. When recording the data cube by scanning an electron probe over the sample, perfect dose efficiency is attained; but due to the low current in nanoprobes, this often is slower, with a smaller field of view. In W. Van den Broek et al. [Ultramicroscopy, 106 (2006) 269], we proposed a new method to record the data cube, which is more dose efficient than an energy filtered series. It produces a set of projections of the data cube and then tomographically reconstructs it. In this article, we demonstrate these projections in practice, we present a simple geometrical model that allows for quantification of the projection angles and we present the first successful experimental reconstruction, all on a standard post-column instrument. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000265345400003 |
Publication Date |
2008-12-10 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
1 |
Open Access |
|
Notes |
Esteem 026019 |
Approved |
Most recent IF: 2.843; 2009 IF: 2.067 |
Call Number |
UA @ lucian @ c:irua:77271 |
Serial |
3671 |
Permanent link to this record |
|
|
|
Author |
Gonnissen, J.; De Backer, A.; den Dekker, A.J.; Sijbers, J.; Van Aert, S. |
Title |
Detecting and locating light atoms from high-resolution STEM images: The quest for a single optimal design |
Type |
A1 Journal article |
Year |
2016 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
170 |
Issue |
170 |
Pages |
128-138 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
Abstract |
In the present paper, the optimal detector design is investigated for both detecting and locating light atoms from high resolution scanning transmission electron microscopy (HR STEM) images. The principles of detection theory are used to quantify the probability of error for the detection of light atoms from HR STEM images. To determine the optimal experiment design for locating light atoms, use is made of the so-called Cramer-Rao Lower Bound (CRLB). It is investigated if a single optimal design can be found for both the detection and location problem of light atoms. Furthermore, the incoming electron dose is optimised for both research goals and it is shown that picometre range precision is feasible for the estimation of the atom positions when using an appropriate incoming electron dose under the optimal detector settings to detect light atoms. |
Address |
Electron Microscopy for Materials Science (EMAT), University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp, Belgium. Electronic address: sandra.vanaert@uantwerpen.be |
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
English |
Wos |
000386925500014 |
Publication Date |
2016-07-26 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
6 |
Open Access |
|
Notes |
The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through project fundings (G.0368.15, G.0369.15 and G.0374.13) and a postdoctoral research grant to A. De Backer. The research leading to these results has also received funding from the European Union Seventh Framework Programme [FP7/2007-2013] under Grant agreement no. 312483 (ESTEEM2). The authors would also like to thank A. Rosenauer for providing access to the STEMsim software and Gerardo T. Martinez for fruitful discussions.; esteem2_jra2 |
Approved |
Most recent IF: 2.843 |
Call Number |
c:irua:135337 c:irua:135337 |
Serial |
4128 |
Permanent link to this record |
|
|
|
Author |
De Backer, A.; van den Bos, K.H.W.; Van den Broek, W.; Sijbers, J.; Van Aert, S. |
Title |
StatSTEM: An efficient approach for accurate and precise model-based quantification of atomic resolution electron microscopy images |
Type |
A1 Journal article |
Year |
2016 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
171 |
Issue |
171 |
Pages |
104-116 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
Abstract |
An efficient model-based estimation algorithm is introduced to quantify the atomic column positions and intensities from atomic resolution (scanning) transmission electron microscopy ((S)TEM) images. This algorithm uses the least squares estimator on image segments containing individual columns fully accounting for overlap between neighbouring columns, enabling the analysis of a large field of view. For this algorithm, the accuracy and precision with which measurements for the atomic column positions and scattering cross-sections from annular dark field (ADF) STEM images can be estimated, has been investigated. The highest attainable precision is reached even for low dose images. Furthermore, the advantages of the model-based approach taking into account overlap between neighbouring columns are highlighted. This is done for the estimation of the distance between two neighbouring columns as a function of their distance and for the estimation of the scattering cross-section which is compared to the integrated intensity from a Voronoi cell. To provide end-users this well-established quantification method, a user friendly program, StatSTEM, is developed which is freely available under a GNU public license. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000389106200014 |
Publication Date |
2016-09-09 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
43 |
Open Access |
|
Notes |
The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through project fundings (G.0393.11, G.0064.10 and G.0374.13), a Ph.D. research grant to K.H.W. van den Bos, and a postdoctoral research grant to A. De Backer. The research leading to these results has received funding from the European Union Seventh Framework Programme under Grant Agreement 312483 – ESTEEM2 (Integrated Infrastructure Initiative-I3). A. Rosenauer is acknowledged for providing the STEMsim program.; esteem2_jra2 |
Approved |
Most recent IF: 2.843 |
Call Number |
EMAT @ emat @ c:irua:135516 |
Serial |
4280 |
Permanent link to this record |
|
|
|
Author |
Gonnissen, J.; De Backer, A.; den Dekker, A.J.; Sijbers, J.; Van Aert, S. |
Title |
Atom-counting in High Resolution Electron Microscopy: TEM or STEM – that's the question |
Type |
A1 Journal article |
Year |
2016 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
174 |
Issue |
174 |
Pages |
112-120 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
Abstract |
In this work, a recently developed quantitative approach based on the principles of detection theory is used in order to determine the possibilities and limitations of High Resolution Scanning Transmission Electron Microscopy (HR STEM) and HR TEM for atom-counting. So far, HR STEM has been shown to be an appropriate imaging mode to count the number of atoms in a projected atomic column. Recently, it has been demonstrated that HR TEM, when using negative spherical aberration imaging, is suitable for atom-counting as well. The capabilities of both imaging techniques are investigated and compared using the probability of error as a criterion. It is shown that for the same incoming electron dose, HR STEM outperforms HR TEM under common practice standards, i.e. when the decision is based on the probability function of the peak intensities in HR TEM and of the scattering cross-sections in HR STEM. If the atom-counting decision is based on the joint probability function of the image pixel values, the dependence of all image pixel intensities as a function of thickness should be known accurately. Under this assumption, the probability of error may decrease significantly for atom-counting in HR TEM and may, in theory, become lower as compared to HR STEM under the predicted optimal experimental settings. However, the commonly used standard for atom-counting in HR STEM leads to a high performance and has been shown to work in practice. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000403342200013 |
Publication Date |
2016-10-27 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
2 |
Open Access |
|
Notes |
The authors gratefully acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through project fundings (G.0368.15N, G.0369.15N, G.0374.13N, and WO.010.16N) and a postdoctoral grant to A. De Backer. The research leading to these results has received funding from the European Union Seventh Framework Programme [FP7/2007-2013] under Grant agreement no. 312483 (ESTEEM2). |
Approved |
Most recent IF: 2.843 |
Call Number |
EMAT @ emat @ c:irua:137102 |
Serial |
4315 |
Permanent link to this record |
|
|
|
Author |
Alania, M.; Altantzis, T.; De Backer, A.; Lobato, I.; Bals, S.; Van Aert, S. |
Title |
Depth sectioning combined with atom-counting in HAADF STEM to retrieve the 3D atomic structure |
Type |
A1 Journal article |
Year |
2016 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
177 |
Issue |
177 |
Pages |
36-42 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
Aberration correction in scanning transmission electron microscopy (STEM) has greatly improved the lateral and depth resolution. When using depth sectioning, a technique during which a series of images is recorded at different defocus values, single impurity atoms can be visualised in three dimensions. In this paper, we investigate new possibilities emerging when combining depth sectioning and precise atom-counting in order to reconstruct nanosized particles in three dimensions. Although the depth resolution does not allow one to precisely locate each atom within an atomic column, it will be shown that the depth location of an atomic column as a whole can be measured precisely. In this manner, the morphology of a nanoparticle can be reconstructed in three dimensions. This will be demonstrated using simulations and experimental data of a gold nanorod. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000401219800006 |
Publication Date |
2016-11-09 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
13 |
Open Access |
OpenAccess |
Notes |
The authors acknowledge financial support from the European Union under the Seventh Framework Program under a contract for an Integrated Infrastructure Initiative. Reference No. 312483-ESTEEM2. S. Bals acknowledges funding from the European Research Council (Starting Grant No. COLOURATOMS 335078). The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through project fundings (G.0374.13N, G.0369.15N and G.0368.15N) and a post-doctoral grant to A. De Backer and T. Altantzis. The authors are grateful to Professor Luis M. Liz-Marzán for providing the sample.; ECAS_Sara; (ROMEO:green; preprint:; postprint:can ; pdfversion:cannot); |
Approved |
Most recent IF: 2.843 |
Call Number |
EMAT @ emat @ c:irua:138015UA @ admin @ c:irua:138015 |
Serial |
4316 |
Permanent link to this record |
|
|
|
Author |
Alania, M.; De Backer, A.; Lobato, I.; Krause, F.F.; Van Dyck, D.; Rosenauer, A.; Van Aert, S. |
Title |
How precise can atoms of a nanocluster be located in 3D using a tilt series of scanning transmission electron microscopy images? |
Type |
A1 Journal article |
Year |
2017 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
181 |
Issue |
181 |
Pages |
134-143 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
Abstract |
In this paper, we investigate how precise atoms of a small nanocluster can ultimately be located in three dimensions (3D) from a tilt series of images acquired using annular dark field (ADF) scanning transmission electron microscopy (STEM). Therefore, we derive an expression for the statistical precision with which the 3D atomic position coordinates can be estimated in a quantitative analysis. Evaluating this statistical precision as a function of the microscope settings also allows us to derive the optimal experimental design. In this manner, the optimal angular tilt range, required electron dose, optimal detector angles, and number of projection images can be determined. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000411170800016 |
Publication Date |
2016-12-15 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
3 |
Open Access |
OpenAccess |
Notes |
The authors acknowledge financial support from the European Union under the Seventh Framework Program under a contract for an Integrated Infrastructure Initiative. Reference No. 312483-ESTEEM2. The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through project fundings (G.0374.13N, G.0369.15N, G.0368.15N, and WO.010.16N) and a post-doctoral grant to A. De Backer, and from the DFG under contract No. RO-2057/4-2. |
Approved |
Most recent IF: 2.843 |
Call Number |
EMAT @ emat @ c:irua:144432 |
Serial |
4618 |
Permanent link to this record |
|
|
|
Author |
De wael, A.; De Backer, A.; Jones, L.; Nellist, P.D.; Van Aert, S. |
Title |
Hybrid statistics-simulations based method for atom-counting from ADF STEM images |
Type |
A1 Journal article |
Year |
2017 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
177 |
Issue |
177 |
Pages |
69-77 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
A hybrid statistics-simulations based method for atom-counting from annular dark field scanning transmission electron microscopy (ADF STEM) images of monotype crystalline nanostructures is presented. Different atom-counting methods already exist for model-like systems. However, the increasing relevance of radiation damage in the study of nanostructures demands a method that allows atom-counting from low dose images with a low signal-to-noise ratio. Therefore, the hybrid method directly includes prior knowledge from image simulations into the existing statistics-based method for atom-counting, and accounts in this manner for possible discrepancies between actual and simulated experimental conditions. It is shown by means of simulations and experiments that this hybrid method outperforms the statistics-based method, especially for low electron doses and small nanoparticles. The analysis of a simulated low dose image of a small nanoparticle suggests that this method allows for far more reliable quantitative analysis of beam-sensitive materials. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000401219800010 |
Publication Date |
2017-01-25 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
8 |
Open Access |
OpenAccess |
Notes |
The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through project fundings (G.0374.13N, G.0368.15N, G.0369.15N, and WO.010.16N), and a postdoctoral research Grant to A. De Backer. The research leading to these results has received funding from the European Union Seventh Framework Programme under Grant Agreement 312483 – ESTEEM2 (Integrated Infrastructure Initiative-I3). The authors are grateful to G.T. Martinez for providing image simulations. |
Approved |
Most recent IF: 2.843 |
Call Number |
EMAT @ emat @ c:irua:141718 |
Serial |
4486 |
Permanent link to this record |
|
|
|
Author |
Schryvers, D.; Salje, E.K.H.; Nishida, M.; De Backer, A.; Idrissi, H.; Van Aert, S. |
Title |
Quantification by aberration corrected (S)TEM of boundaries formed by symmetry breaking phase transformations |
Type |
A1 Journal article |
Year |
2017 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
176 |
Issue |
|
Pages |
194-199 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
The present contribution gives a review of recent quantification work of atom displacements, atom site occupations and level of crystallinity in various systems and based on aberration corrected HR(S)TEM images. Depending on the case studied, picometer range precisions for individual distances can be obtained, boundary widths at the unit cell level determined or statistical evolutions of fractions of the ordered areas calculated. In all of these cases, these quantitative measures imply new routes for the applications of the respective materials. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000403992200026 |
Publication Date |
2017-01-09 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
1 |
Open Access |
OpenAccess |
Notes |
The authors acknowledge financial support from the Fund for Scientific Research-Flanders (G.0064.10N, G.0393.11N, G.0374.13N, G.0368.15N, G.0369.15N) and the Flemish Hercules 3 program for large infrastructure as well as financial support from the European Union Seventh Framework Programme (FP7/2007 – 2013) under Grant agreement no. 312483 (ESTEEM2). EKHS thanks EPSRC (EP/ K009702/1) and the Leverhulme trust (EM-2016-004) for support. DS and MN acknowledge financial support from the Japan Society for the Promotion of Science (JSPS, Japan) through the Grant-in-Aid for Scientific Research (A: No. 26249090) and the Strategic Young Researcher Overseas Visits Program for Accelerating Brain Circulation (R2408). |
Approved |
Most recent IF: 2.843 |
Call Number |
EMAT @ emat @c:irua:149654 |
Serial |
4914 |
Permanent link to this record |
|
|
|
Author |
van den Bos, K.H.W.; Janssens, L.; De Backer, A.; Nellist, P.D.; Van Aert, S. |
Title |
The atomic lensing model: new opportunities for atom-by-atom metrology of heterogeneous nanomaterials |
Type |
A1 Journal article |
Year |
2019 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
203 |
Issue |
|
Pages |
155 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
The atomic lensing model has been proposed as a promising method facilitating atom-counting in heterogeneous nanocrystals [1]. Here, image simulations will validate the model, which describes dynamical diffraction as a superposition of individual atoms focussing the incident electrons. It will be demonstrated that the model is reliable in the annular dark field regime for crystals having columns containing dozens of atoms. By using the principles of statistical detection theory, it will be shown that this model gives new opportunities for detecting compositional differences. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000465021000020 |
Publication Date |
2018-12-06 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
4 |
Open Access |
OpenAccess |
Notes |
The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through project fundings (G.0369.15N, G.0502.18N and WO.010.16N), and by personal grants to K.H.W. van den Bos and A. De Backer. This project has received funding from the European Research Council (ERC) under the European Unions Horizon 2020 research and innovation programme (grant agreement No. 770887). |
Approved |
Most recent IF: 2.843 |
Call Number |
EMAT @ emat @UA @ admin @ c:irua:155721 |
Serial |
5074 |
Permanent link to this record |
|
|
|
Author |
De wael, A.; De Backer, A.; Lobato, I.; Van Aert, S. |
Title |
Modelling ADF STEM images using elliptical Gaussian peaks and its effects on the quantification of structure parameters in the presence of sample tilt |
Type |
A1 Journal article |
Year |
2021 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
|
Issue |
|
Pages |
113391 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
A small sample tilt away from a main zone axis orientation results in an elongation of the atomic columns in ADF STEM images. An often posed research question is therefore whether the ADF STEM image intensities of tilted nanomaterials should be quantified using a parametric imaging model consisting of elliptical rather than the currently used symmetrical peaks. To this purpose, simulated ADF STEM images corresponding to different amounts of sample tilt are studied using a parametric imaging model that consists of superimposed 2D elliptical Gaussian peaks on the one hand and symmetrical Gaussian peaks on the other hand. We investigate the quantification of structural parameters such as atomic column positions and scattering cross sections using both parametric imaging models. In this manner, we quantitatively study what can be gained from this elliptical model for quantitative ADF STEM, despite the increased parameter space and computational effort. Although a qualitative improvement can be achieved, no significant quantitative improvement in the estimated structure parameters is achieved by the elliptical model as compared to the symmetrical model. The decrease in scattering cross sections with increasing sample tilt is even identical for both types of parametric imaging models. This impedes direct comparison with zone axis image simulations. Nonetheless, we demonstrate how reliable atom-counting can still be achieved in the presence of small sample tilt. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000704334200001 |
Publication Date |
2021-09-24 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
|
Open Access |
OpenAccess |
Notes |
This project has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (Grant Agreement No. 770887 and No. 823717 ESTEEM3). The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through grants to A.D.w. and A.D.B. and projects G.0502.18N, G.0267.18N, and EOS 30489208. S.V.A. acknowledges TOP BOF funding from the University of Antwerp.; esteem3JRA; esteem3reported |
Approved |
Most recent IF: 2.843 |
Call Number |
EMAT @ emat @c:irua:181462 |
Serial |
6810 |
Permanent link to this record |
|
|
|
Author |
De wael, A.; De Backer, A.; Yu, C.-P.; Sentürk, D.G.; Lobato, I.; Faes, C.; Van Aert, S. |
Title |
Three Approaches for Representing the Statistical Uncertainty on Atom-Counting Results in Quantitative ADF STEM |
Type |
A1 Journal article |
Year |
2022 |
Publication |
Microscopy and microanalysis |
Abbreviated Journal |
Microsc Microanal |
Volume |
|
Issue |
|
Pages |
1-9 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
A decade ago, a statistics-based method was introduced to count the number of atoms from annular dark-field scanning transmission electron microscopy (ADF STEM) images. In the past years, this method was successfully applied to nanocrystals of arbitrary shape, size, and composition (and its high accuracy and precision has been demonstrated). However, the counting results obtained from this statistical framework are so far presented without a visualization of the actual uncertainty about this estimate. In this paper, we present three approaches that can be used to represent counting results together with their statistical error, and discuss which approach is most suited for further use based on simulations and an experimental ADF STEM image. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000854930500001 |
Publication Date |
2022-09-19 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1431-9276 |
ISBN |
|
Additional Links |
UA library record; WoS full record |
Impact Factor |
2.8 |
Times cited |
|
Open Access |
OpenAccess |
Notes |
This project has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (Grant Agreement No. 770887 and No. 823717 ESTEEM3). The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through grants to A.D.w. and A.D.B. and projects G.0502.18N, G.0267.18N, and EOS 30489208. S.V.A. acknowledges TOP BOF funding from the University of Antwerp. The authors are grateful to L.M. Liz-Marzán (CIC biomaGUNE and Ikerbasque) for providing the samples. esteem3reported; esteem3jra |
Approved |
Most recent IF: 2.8 |
Call Number |
EMAT @ emat @c:irua:190585 |
Serial |
7119 |
Permanent link to this record |
|
|
|
Author |
Vos, W.; de Backer, J.; Poli, G.; De Volder, A.; Ghys, L.; Van Holsbeke, C.; Vinchurkar, S.; De Backer, L.; de Backer, W. |
Title |
Novel functional imaging of changes in small airways of patients treated with extrafine beclomethasone/formoterol |
Type |
A1 Journal article |
Year |
2013 |
Publication |
Respiration |
Abbreviated Journal |
Respiration |
Volume |
86 |
Issue |
5 |
Pages |
393-401 |
Keywords |
A1 Journal article; Biophysics and Biomedical Physics; Condensed Matter Theory (CMT); Laboratory Experimental Medicine and Pediatrics (LEMP) |
Abstract |
Background: Inhaled formulations using extrafine particles of long-acting beta(2)-agonists and corticosteroids were developed to optimize asthma treatment. Findings that these combinations reach and treat smaller airways more effectively are predominantly based on general non-specific outcomes with little information on regional characteristics. Objectives: This study aims to assess long-term effects of extrafine beclomethasone/formoterol on small airways of asthmatic patients using novel functional imaging methods. Methods: Twenty-four stable asthma patients were subdivided into three groups (steroid naive, n = 7; partially controlled, n = 6; well controlled, n = 11). Current treatment was switched to a fixed combination of extrafine beclomethasone/formoterol (Foster (R); Chiesi Pharmaceuticals, Parma, Italy). Patients underwent lung function evaluation and thorax high-resolution computerized tomography (HRCT) scan. Local airway resistance was obtained from computational fluid dynamics (CFD). Results: After 6 months, the entire population showed improvement in pre-bronchodilation imaging parameters, including small airway volume (p = 0.0007), resistance (p = 0.011), and asthma control score (p = 0.016). Changes in small airway volume correlated with changes in asthma control score (p = 0.004). Forced expiratory volume in 1 s (p = 0.044) and exhaled nitric oxide (p = 0.040) also improved. Functional imaging provided more detail and clinical relevance compared to lung function tests, especially in the well-controlled group where only functional imaging parameters showed significant improvement, while the correlation with asthma control score remained. Conclusions: Extrafine beclomethasone/formoterol results in a significant reduction of small airway obstruction, detectable by functional imaging (HRCT/CFD). Changes in imaging parameters correlated significantly with clinically relevant improvements. This indicates that functional imaging is a useful tool for sensitive assessment of changes in the respiratory system after asthma treatment. Copyright (C) 2013 S. Karger AG, Basel |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Basel |
Editor |
|
Language |
|
Wos |
000329046200006 |
Publication Date |
2013-04-12 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1423-0356;0025-7931; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.772 |
Times cited |
30 |
Open Access |
|
Notes |
; ; |
Approved |
Most recent IF: 2.772; 2013 IF: 2.924 |
Call Number |
UA @ lucian @ c:irua:113762 |
Serial |
2376 |
Permanent link to this record |
|
|
|
Author |
van Holsbeke, C.; de Backer, J.; Vos, W.; Verdonck, P.; van Ransbeeck, P.; Claessens, T.; Braem, M.; Vanderveken, O.; de Backer, W. |
Title |
Anatomical and functional changes in the upper airways of sleep apnea patients due to mandibular repositioning: a large scale study |
Type |
A1 Journal article |
Year |
2011 |
Publication |
Journal of biomechanics |
Abbreviated Journal |
J Biomech |
Volume |
44 |
Issue |
3 |
Pages |
442-449 |
Keywords |
A1 Journal article; Condensed Matter Theory (CMT); Vision lab; Laboratory Experimental Medicine and Pediatrics (LEMP); Translational Neurosciences (TNW) |
Abstract |
The obstructive sleep apnea-hypopnea syndrome (OSAHS) is a sleep related breathing disorder. A popular treatment is the use of a mandibular repositioning appliance (MRA) which advances the mandibula during the sleep and decreases the collapsibility of the upper airway. The success rate of such a device is, however, limited and very variable within a population of patients. Previous studies using computational fluid dynamics have shown that there is a decrease in upper airway resistance in patients who improve clinically due to an MRA. In this article, correlations between patient-specific anatomical and functional parameters are studied to examine how MRA induced biomechanical changes will have an impact on the upper airway resistance. Low-dose computed tomography (CT) scans are made from 143 patients suffering from OSAHS. A baseline scan and a scan after mandibular repositioning (MR) are performed in order to study variations in parameters. It is found that MR using a simulation bite is able to induce resistance changes by changing the pharyngeal lumen. The change in minimal cross-sectional area is the best parameter to predict the change in upper airway resistance. Looking at baseline values, the ideal patients for MR induced resistance decrease seem to be women with short airways, high initial resistance and no baseline occlusion. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
New York, N.Y. |
Editor |
|
Language |
|
Wos |
000287551000014 |
Publication Date |
2010-10-23 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0021-9290; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.664 |
Times cited |
23 |
Open Access |
|
Notes |
; ; |
Approved |
Most recent IF: 2.664; 2011 IF: 2.434 |
Call Number |
UA @ lucian @ c:irua:85305 |
Serial |
112 |
Permanent link to this record |