Home | << 1 2 3 >> |
Records | |||||
---|---|---|---|---|---|
Author | Savchenko, T.M.; Buzzi, M.; Howald, L.; Ruta, S.; Vijayakumar, J.; Timm, M.; Bracher, D.; Saha, S.; Derlet, P.M.; Béché, A.; Verbeeck, J.; Chantrell, R.W.; Vaz, C.A.F.; Nolting, F.; Kleibert, A. | ||||
Title | Single femtosecond laser pulse excitation of individual cobalt nanoparticles | Type | A1 Journal article | ||
Year | 2020 | Publication | Physical Review B | Abbreviated Journal | Phys Rev B |
Volume | 102 | Issue | 20 | Pages | 205418 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Laser-induced manipulation of magnetism at the nanoscale is a rapidly growing research topic with potential for applications in spintronics. In this work, we address the role of the scattering cross section, thermal effects, and laser fluence on the magnetic, structural, and chemical stability of individual magnetic nanoparticles excited by single femtosecond laser pulses. We find that the energy transfer from the fs laser pulse to the nanoparticles is limited by the Rayleigh scattering cross section, which in combination with the light absorption of the supporting substrate and protective layers determines the increase in the nanoparticle temperature. We investigate individual Co nanoparticles (8 to 20 nm in size) as a prototypical model system, using x-ray photoemission electron microscopy and scanning electron microscopy upon excitation with single femtosecond laser pulses of varying intensity and polarization. In agreement with calculations, we find no deterministic or stochastic reversal of the magnetization in the nanoparticles up to intensities where ultrafast demagnetization or all-optical switching is typically reported in thin films. Instead, at higher fluences, the laser pulse excitation leads to photo-chemical reactions of the nanoparticles with the protective layer, which results in an irreversible change in the magnetic properties. Based on our findings, we discuss the conditions required for achieving laser-induced switching in isolated nanomagnets. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000589602000005 | Publication Date | 2020-11-16 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 2469-9950 | ISBN | Additional Links | UA library record; WoS full record | |
Impact Factor | 3.7 | Times cited | 1 | Open Access | OpenAccess |
Notes | This work received funding by the Swiss National Foundation (SNF) (Grants No. 200021160186 and No. 2002153540), the Swiss Nanoscience Institute (SNI) (Grant No. SNI P1502), the European Union’s Horizon 2020 research and innovation programme under Grant Agreement No. 737093 (FEMTOTERABYTE), and the COST Action CA17123 (MAGNETOFON). Part of this work was performed at the SIM beamline of the Swiss Light Source (SLS), Paul Scherrer Institut, Villigen, Switzerland. Part of the simulations were undertaken on the VIKING cluster, which is a high-performance compute facility provided by the University of York. We kindly acknowledge Anja Weber from PSI for preparation of substrates with marker structures. A.B. and Jo Verbeeck acknowledge funding through FWO Project No. G093417N (“Compressed sensing enabling low dose imaging in transmission electron microscopy”) from the Flanders Research Fund. Jo Verbeeck acknowledges funding from the European Union’s Horizon 2020 research and innovation program under Grant Agreement No. 823717 – ESTEEM3. S.S. acknowledges ETH Zurich Post-Doctoral fellowship and Marie Curie actions for people COFUND program.; esteem3JRA; esteem3reported | Approved | Most recent IF: 3.7; 2020 IF: 3.836 | ||
Call Number | EMAT @ emat @c:irua:174273 | Serial | 6669 | ||
Permanent link to this record | |||||
Author | Béché, A.; Goris, B.; Freitag, B.; Verbeeck, J. | ||||
Title | Development of a fast electromagnetic beam blanker for compressed sensing in scanning transmission electron microscopy | Type | A1 Journal article | ||
Year | 2016 | Publication | Applied physics letters | Abbreviated Journal | Appl Phys Lett |
Volume | 108 | Issue | 108 | Pages | 093103 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | The concept of compressed sensing was recently proposed to significantly reduce the electron dose in scanning transmission electron microscopy (STEM) while still maintaining the main features in the image. Here, an experimental setup based on an electromagnetic beam blanker placed in the condenser plane of a STEM is proposed. The beam blanker deflects the beam with a random pattern, while the scanning coils are moving the beam in the usual scan pattern. Experimental images at both the medium scale and high resolution are acquired and reconstructed based on a discrete cosine algorithm. The obtained results confirm that compressed sensing is highly attractive to limit beam damage in experimental STEM even though some remaining artifacts need to be resolved. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000375329200043 | Publication Date | 2016-03-01 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0003-6951 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 3.411 | Times cited | 40 | Open Access | |
Notes | A.B and J.V. acknowledge funding from the European Research Council under the 7th Framework Program (FP7), ERC Starting Grant No. 278510 VORTEX and under a contract for an Integrated Infrastructure Initiative (Reference No. 312483 ESTEEM2), from the GOA project SOLARPAINT and the POC project I13/009 from the University of Antwerp. B.G. acknowledges the Research Foundation Flanders (FWO Vlaanderen) for a postdoctoral research grant. The QuAnTem microscope was partially funded by the Hercules Foundation. We thank Zhaoliang Liao from the Mesa+ laboratory at the University of Twente for the perovskite test sample.; esteem2jra3 ECASJO; | Approved | Most recent IF: 3.411 | ||
Call Number | c:irua:131895 c:irua:131895UA @ admin @ c:irua:131895 | Serial | 4023 | ||
Permanent link to this record | |||||
Author | Jones, E.; Cooper, D.; Rouvière, J.-L.; Béché, A.; Azize, M.; Palacios, T.; Gradecak, S. | ||||
Title | Towards rapid nanoscale measurement of strain in III-nitride heterostructures | Type | A1 Journal article | ||
Year | 2013 | Publication | Applied Physics Letters | Abbreviated Journal | Appl Phys Lett |
Volume | 103 | Issue | Pages | 231904 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | We report the structural and compositional nanoscale characterization of InAlN/GaN nanoribbon-structured high electron mobility transistors (HEMTs) through the use of geometric phase analysis (GPA) and nanobeam electron diffraction (NBED). The strain distribution in the HEMT layer is quantified and compared to the expected strain profile for the nominal structure predicted by finite element analysis (FEA). Using the experimental strain results, the actual structure is determined and used to modify the FEA model. The improved fit of the model demonstrates that GPA and NBED provide a powerful platform for routine and rapid characterization of strain in III-V semiconducting device systems leading to insights into device evolution during processing and future device optimization. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | American Institute of Physics | Place of Publication | New York, N.Y. | Editor | |
Language | Wos | 000328634900025 | Publication Date | 2013-12-03 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0003-6951; 1077-3118 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 3.411 | Times cited | 6 | Open Access | |
Notes | Approved | Most recent IF: 3.411; 2013 IF: 3.515 | |||
Call Number | UA @ lucian @ c:irua:136443 | Serial | 4513 | ||
Permanent link to this record | |||||
Author | Cooper, D.; Rouvière, J.-L.; Béché, A.; Kadkhodazadeh, S.; Semenova, E.S.; Dunin-Borkowsk, R. | ||||
Title | Quantitative strain mapping of InAs/InP quantum dots with 1 nm spatial resolution using dark field electron holography | Type | A1 Journal article | ||
Year | 2011 | Publication | Applied physics letters | Abbreviated Journal | Appl Phys Lett |
Volume | 99 | Issue | Pages | 261911-261913 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | The optical properties of semiconductor quantum dots are greatly influenced by their strain state. Dark field electron holography has been used to measure the strain in InAsquantum dotsgrown in InP with a spatial resolution of 1 nm. A strain value of 5.4% ± 0.1% has been determined which is consistent with both measurements made by geometrical phase analysis of high angle annular dark field scanning transmission electron microscopy images and with simulations. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | American Institute of Physics | Place of Publication | New York, N.Y. | Editor | |
Language | Wos | 000298638500027 | Publication Date | 2012-01-03 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0003-6951; 1077-3118 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 3.411 | Times cited | 26 | Open Access | |
Notes | Approved | Most recent IF: 3.411; 2011 IF: 3.844 | |||
Call Number | UA @ lucian @ c:irua:136428 | Serial | 4507 | ||
Permanent link to this record | |||||
Author | Cooper, D.; Le Royer, C.; Béché, A.; Rouvière, J.-L. | ||||
Title | Strain mapping for the silicon-on-insulator generation of semiconductor devices by high-angle annular dark field scanning electron transmission microscopy | Type | A1 Journal article | ||
Year | 2012 | Publication | Applied Physics Letters | Abbreviated Journal | Appl Phys Lett |
Volume | 100 | Issue | Pages | 233121 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | The strain in pMOS p-type metal-oxide-semiconductor devicesgrown on silicon-on-insulator substrates has been measured by using the geometrical phase analysis of high angle annular dark field scanning electron microscopy. We show that by using the latest generations of electron microscopes, the strain can now be quantitatively measured with a large field of view, a spatial resolution as low as 1 nm with a sensitivity as good as 0.15%. This technique is extremely flexible, provides both structural and strain information, and can be applied to all types of nanoscale materials both quickly and easily. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | American Institute of Physics | Place of Publication | New York, N.Y. | Editor | |
Language | Wos | Publication Date | 2012-06-08 | ||
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0003-6951; 1077-3118 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 3.411 | Times cited | Open Access | ||
Notes | Approved | Most recent IF: 3.411; 2012 IF: 3.794 | |||
Call Number | UA @ lucian @ c:irua:136432 | Serial | 4509 | ||
Permanent link to this record | |||||
Author | Cooper, D.; Denneulin, T.; Barnes, J.-P.; Hartmann, J.-M.; Hutin, L.; Le Royer, C.; Béché, A.; Rouvière, J.-L. | ||||
Title | Strain mapping with nm-scale resolution for the silicon-on-insulator generation of semiconductor devices by advanced electron microscopy | Type | A1 Journal article | ||
Year | 2012 | Publication | Applied Physics Letters | Abbreviated Journal | Appl Phys Lett |
Volume | 112 | Issue | Pages | 124505 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Strain engineering in the conduction channel is a cost effective method of boosting the performance in state-of-the-art semiconductor devices. However, given the small dimensions of these devices, it is difficult to quantitatively measure the strain with the required spatial resolution. Three different transmission electron microscopy techniques, high-angle annular dark field scanning transmission electron microscopy, dark field electron holography, and nanobeam electron diffraction have been applied to measure the strain in simple bulk and SOI calibration specimens. These techniques are then applied to different gate length SiGe SOI pFET devices in order to measure the strain in the conduction channel. For these devices, improved spatial resolution is required, and strain maps with spatial resolutions as good as 1 nm have been achieved. Finally, we discuss the relative advantages and disadvantages of using these three different techniques when used for strain measurement. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | American Institute of Physics | Place of Publication | New York, N.Y. | Editor | |
Language | Wos | 000312829400128 | Publication Date | 2012-12-19 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0003-6951; 1077-3118 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 3.411 | Times cited | 14 | Open Access | |
Notes | Approved | Most recent IF: 3.411; 2012 IF: 3.794 | |||
Call Number | UA @ lucian @ c:irua:136433 | Serial | 4510 | ||
Permanent link to this record | |||||
Author | Rouvière, J.-L.; Béché, A.; Martin, Y.; Denneulin, T.; Cooper, D. | ||||
Title | Improved strain precision with high spatial resolution using nanobeam precession electron diffraction | Type | A1 Journal article | ||
Year | 2013 | Publication | Applied physics letters | Abbreviated Journal | Appl Phys Lett |
Volume | 103 | Issue | Pages | 241913 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | NanoBeam Electron Diffraction is a simple and efficient technique to measure strain in nanostructures. Here, we show that improved results can be obtained by precessing the electron beam while maintaining a few nanometer probe size, i.e., by doing Nanobeam Precession Electron Diffraction (N-PED). The precession of the beam makes the diffraction spots more uniform and numerous, making N-PED more robust and precise. In N-PED, smaller probe size and better precision are achieved by having diffraction disks instead of diffraction dots. Precision in the strain measurement better than 2 × 10−4 is obtained with a probe size approaching 1 nm in diameter. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | American Institute of Physics | Place of Publication | New York, N.Y. | Editor | |
Language | Wos | 000328706500031 | Publication Date | 2013-12-14 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0003-6951; 1077-3118 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 3.411 | Times cited | 53 | Open Access | |
Notes | Approved | Most recent IF: 3.411; 2013 IF: 3.515 | |||
Call Number | UA @ lucian @ c:irua:136442 | Serial | 4502 | ||
Permanent link to this record | |||||
Author | Jannis, D.; Müller-Caspary, K.; Béché, A.; Oelsner, A.; Verbeeck, J. | ||||
Title | Spectroscopic coincidence experiments in transmission electron microscopy | Type | A1 Journal article | ||
Year | 2019 | Publication | Applied physics letters | Abbreviated Journal | Appl Phys Lett |
Volume | 114 | Issue | 14 | Pages | 143101 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | We demonstrate the feasibility of coincidence measurements on a conventional transmission electron microscope, revealing the temporal correlation between electron energy loss spectroscopy (EELS) and energy dispersive X-ray (EDX) spectroscopy events. We make use of a delay line detector with ps-range time resolution attached to a modified EELS spectrometer. We demonstrate that coincidence between both events, related to the excitation and deexcitation of atoms in a crystal, provides added information not present in the individual EELS or EDX spectra. In particular, the method provides EELS with a significantly suppressed or even removed background, overcoming the many difficulties with conventional parametric background fitting as it uses no assumptions on the shape of the background, requires no user input and does not suffer from counting noise originating from the background signal. This is highly attractive, especially when low concentrations of elements need to be detected in a matrix of other elements. |
||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000464450200022 | Publication Date | 2019-04-08 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0003-6951 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 3.411 | Times cited | 18 | Open Access | OpenAccess |
Notes | Fonds Wetenschappelijk Onderzoek, G093417 ; Horizon 2020 Framework Programme, 823717 ESTEEM3 ; Helmholtz Association, VH-NG-1327 ; | Approved | Most recent IF: 3.411 | ||
Call Number | EMAT @ emat @UA @ admin @ c:irua:159155 | Serial | 5168 | ||
Permanent link to this record | |||||
Author | Guzzinati, G.; Ghielens, W.; Mahr, C.; Béché, A.; Rosenauer, A.; Calders, T.; Verbeeck, J. | ||||
Title | Electron Bessel beam diffraction for precise and accurate nanoscale strain mapping | Type | A1 Journal article | ||
Year | 2019 | Publication | Applied physics letters | Abbreviated Journal | Appl Phys Lett |
Volume | 114 | Issue | 24 | Pages | 243501 |
Keywords | A1 Journal article; ADReM Data Lab (ADReM); Electron microscopy for materials research (EMAT) | ||||
Abstract | Strain has a strong effect on the properties of materials and the performance of electronic devices. Their ever shrinking size translates into a constant demand for accurate and precise measurement methods with a very high spatial resolution. In this regard, transmission electron microscopes are key instruments thanks to their ability to map strain with a subnanometer resolution. Here, we present a method to measure strain at the nanometer scale based on the diffraction of electron Bessel beams. We demonstrate that our method offers a strain sensitivity better than 2.5 × 10−4 and an accuracy of 1.5 × 10−3, competing with, or outperforming, the best existing methods with a simple and easy to use experimental setup. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000472599100019 | Publication Date | 2019-06-17 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0003-6951 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 3.411 | Times cited | 17 | Open Access | OpenAccess |
Notes | Deutsche Forschungsgemeinschaft, RO2057/12-2 ; Fonds Wetenschappelijk Onderzoek, G.0934.17N ; | Approved | Most recent IF: 3.411 | ||
Call Number | EMAT @ emat @UA @ admin @ c:irua:160119 | Serial | 5181 | ||
Permanent link to this record | |||||
Author | Guzzinati, G.; Clark, L.; Béché, A.; Verbeeck, J. | ||||
Title | Measuring the orbital angular momentum of electron beams | Type | A1 Journal article | ||
Year | 2014 | Publication | Physical review : A : atomic, molecular and optical physics | Abbreviated Journal | Phys Rev A |
Volume | 89 | Issue | Pages | 025803 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | The recent demonstration of electron vortex beams has opened up the new possibility of studying orbital angular momentum (OAM) in the interaction between electron beams and matter. To this aim, methods to analyze the OAM of an electron beam are fundamentally important and a necessary next step. We demonstrate the measurement of electron beam OAM through a variety of techniques. The use of forked holographic masks, diffraction from geometric apertures, and diffraction from a knife edge and the application of an astigmatic lens are all experimentally demonstrated. The viability and limitations of each are discussed with supporting numerical simulations. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Lancaster, Pa | Editor | ||
Language | Wos | 000332224100014 | Publication Date | 2014-02-13 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 1050-2947;1094-1622; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.925 | Times cited | 42 | Open Access | |
Notes | Vortex; FP7; Countatoms; ESTEEM2; esteem2jra3 ECASJO; | Approved | Most recent IF: 2.925; 2014 IF: 2.808 | ||
Call Number | UA @ lucian @ c:irua:114577UA @ admin @ c:irua:114577 | Serial | 1972 | ||
Permanent link to this record | |||||
Author | Clark, L.; Béché, A.; Guzzinati, G.; Verbeeck, J. | ||||
Title | Quantitative measurement of orbital angular momentum in electron microscopy | Type | A1 Journal article | ||
Year | 2014 | Publication | Physical review : A : atomic, molecular and optical physics | Abbreviated Journal | Phys Rev A |
Volume | 89 | Issue | 5 | Pages | 053818 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Electron vortex beams have been predicted to enable atomic scale magnetic information measurement, via transfer of orbital angular momentum. Research so far has focused on developing production techniques and applications of these beams. However, methods to measure the outgoing orbital angular momentum distribution are also a crucial requirement towards this goal. Here, we use a method to obtain the orbital angular momentum decomposition of an electron beam, using a multipinhole interferometer. We demonstrate both its ability to accurately measure orbital angular momentum distribution, and its experimental limitations when used in a transmission electron microscope. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Lancaster, Pa | Editor | ||
Language | Wos | 000335826300012 | Publication Date | 2014-05-13 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 1050-2947;1094-1622; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.925 | Times cited | 23 | Open Access | |
Notes | 7th Framework Program (FP7); ERC Starting Grant No. 278510- VORTEX 7th Framework Program (FP7) under a contract for an Integrated Infrastructure Initiative (Reference No. 312483 ESTEEM2). 7th Framework Program (FP7), ERC Grant No. 246791- COUNTATOMS. SP – 053818-1; esteem2jra3 ECASJO; | Approved | Most recent IF: 2.925; 2014 IF: 2.808 | ||
Call Number | UA @ lucian @ c:irua:117093UA @ admin @ c:irua:117093 | Serial | 2758 | ||
Permanent link to this record | |||||
Author | Clark, L.; Guzzinati, G.; Béché, A.; Lubk, A.; Verbeeck, J. | ||||
Title | Symmetry-constrained electron vortex propagation | Type | A1 Journal article | ||
Year | 2016 | Publication | Physical review A | Abbreviated Journal | Phys Rev A |
Volume | 93 | Issue | 93 | Pages | 063840 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Electron vortex beams hold great promise for development in transmission electron microscopy but have yet to be widely adopted. This is partly due to the complex set of interactions that occur between a beam carrying orbital angular momentum (OAM) and a sample. Herein, the system is simplified to focus on the interaction between geometrical symmetries, OAM, and topology. We present multiple simulations alongside experimental data to study the behavior of a variety of electron vortex beams after interacting with apertures of different symmetries and investigate the effect on their OAM and vortex structure, both in the far field and under free-space propagation. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000378197200006 | Publication Date | 2016-06-23 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 2469-9926 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.925 | Times cited | 7 | Open Access | |
Notes | L.C., A.B., G.G., and J.V. acknowledge funding from the European Research Council under the 7th Framework Program (FP7), ERC Starting Grant No. 278510—VORTEX. J.V. and A.L. acknowledge financial support from the European Union through the 7th Framework Program (FP7) under a contract for an Integrated Infrastructure Initiative (Reference No. 312483 ESTEEM2). The Qu-Ant-EM microscope was partly funded by the Hercules fund of the Flemish Government.; esteem2jra3; ECASJO; | Approved | Most recent IF: 2.925 | ||
Call Number | c:irua:134086 c:irua:134086 | Serial | 4090 | ||
Permanent link to this record | |||||
Author | de Backer, A.; Martinez, G.T.; MacArthur, K.E.; Jones, L.; Béché, A.; Nellist, P.D.; Van Aert, S. | ||||
Title | Dose limited reliability of quantitative annular dark field scanning transmission electron microscopy for nano-particle atom-counting | Type | A1 Journal article | ||
Year | 2015 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 151 | Issue | 151 | Pages | 56-61 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Quantitative annular dark field scanning transmission electron microscopy (ADF STEM) has become a powerful technique to characterise nano-particles on an atomic scale. Because of their limited size and beam sensitivity, the atomic structure of such particles may become extremely challenging to determine. Therefore keeping the incoming electron dose to a minimum is important. However, this may reduce the reliability of quantitative ADF STEM which will here be demonstrated for nano-particle atom-counting. Based on experimental ADF STEM images of a real industrial catalyst, we discuss the limits for counting the number of atoms in a projected atomic column with single atom sensitivity. We diagnose these limits by combining a thorough statistical method and detailed image simulations. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000351237800008 | Publication Date | 2014-12-03 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 29 | Open Access | |
Notes | 312483 Esteem2; 278510 Vortex; Fwo G039311; G006410; G037413; esteem2ta; ECASJO; | Approved | Most recent IF: 2.843; 2015 IF: 2.436 | ||
Call Number | c:irua:123927 c:irua:123927 | Serial | 753 | ||
Permanent link to this record | |||||
Author | Verbeeck, J.; Béché, A.; van den Broek, W. | ||||
Title | A holographic method to measure the source size broadening in STEM | Type | A1 Journal article | ||
Year | 2012 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 120 | Issue | Pages | 35-40 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Source size broadening is an important resolution limiting effect in modern STEM experiments. Here, we propose an alternative method to measure the source size broadening making use of a holographic biprism to create interference patterns in an empty Ronchigram. This allows us to measure the exact shape of the source size broadening with a much better sampling than previously possible. We find that the shape of the demagnified source deviates considerably from a Gaussian profile that is often assumed. We fit the profile with a linear combination of a Gaussian and a bivariate Cauchy distribution showing that even though the full width at half maximum is similar to previously reported measurements, the tails of the profile are considerable wider. This is of fundamental importance for quantitative comparison of STEM simulations with experiments as these tails make the image contrast dependent on the interatomic distance, an effect that cannot be reproduced by a single Gaussian profile of fixed width alone. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000308082600005 | Publication Date | 2012-06-01 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 29 | Open Access | |
Notes | This work was supported by funding from the European Research Council under the 7th Framework Program (FP7), ERC Grant no. 246791 COUNTATOMS and ERC Starting Grant 278510 VORTEX. The Qu-Ant-EM microscope was partly funded by the Hercules fund from the Flemish Government. W. Van den Broek acknowledges funding from the Condor project, a project under the supervision of the Embedded Systems Institute (ESI) and FEI. This project is partially supported by the Dutch Ministry of Economic Affairs under the BSIK program. ECASJO_; | Approved | Most recent IF: 2.843; 2012 IF: 2.470 | ||
Call Number | UA @ lucian @ c:irua:100466UA @ admin @ c:irua:100466 | Serial | 1483 | ||
Permanent link to this record | |||||
Author | Verbeeck, J.; Tian, H.; Béché, A. | ||||
Title | A new way of producing electron vortex probes for STEM | Type | A1 Journal article | ||
Year | 2012 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 113 | Issue | Pages | 83-87 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | A spiral holographic aperture is used in the condensor plane of a scanning transmission electron microscope to produce a focussed electron vortex probe carrying a topological charge of either −1, 0 or +1. The spiral aperture design has a major advantage over the previously used forked aperture in that the three beams with topological charge m=−1, 0, and 1 are not side by side in the specimen plane, but rather on top of each other, focussed at different heights. This allows us to have only one selected beam in focus on the sample while the others contribute only to a background signal. In this paper we describe the working principle as well as first experimental results demonstrating atomic resolution HAADF STEM images obtained with electron vortex probes. These results pave the way for atomic resolution magnetic information when combined with electron energy loss spectroscopy. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000300554400002 | Publication Date | 2011-10-31 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 62 | Open Access | |
Notes | J.V. wants to thank Miles Padgett for suggesting this setup and pointing to the relevant optics literature. Peter Schattschneider is acknowledged for in depth discussions on related topics. J.V acknowledges funding from the European Research Council under the 7th Framework Program (FP7), ERC Grant no. 46791-COUN-TATOMS and ERC Starting Grant no. 278510 VORTEX. The Qu-Ant-EM microscope is partially funded by the Hercules fund of the Flemish Government. ECASJO_; | Approved | Most recent IF: 2.843; 2012 IF: 2.470 | ||
Call Number | UA @ lucian @ c:irua:93624UA @ admin @ c:irua:93624 | Serial | 2336 | ||
Permanent link to this record | |||||
Author | Guzzinati, G.; Clark, L.; Béché, A.; Juchtmans, R.; Van Boxem, R.; Mazilu, M.; Verbeeck, J. | ||||
Title | Prospects for versatile phase manipulation in the TEM : beyond aberration correction | Type | A1 Journal article | ||
Year | 2015 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 151 | Issue | 151 | Pages | 85-93 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | In this paper we explore the desirability of a transmission electron microscope in which the phase of the electron wave can be freely controlled. We discuss different existing methods to manipulate the phase of the electron wave and their limitations. We show how with the help of current techniques the electron wave can already be crafted into specific classes of waves each having their own peculiar properties. Assuming a versatile phase modulation device is feasible, we explore possible benefits and methods that could come into existence borrowing from light optics where the so-called spatial light modulators provide programmable phase plates for quite some time now. We demonstrate that a fully controllable phase plate building on Harald Rose׳s legacy in aberration correction and electron optics in general would open an exciting field of research and applications. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000351237800012 | Publication Date | 2014-10-22 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 19 | Open Access | |
Notes | 278510 Vortex; Fwo; 312483 Esteem2; esteem2jra2; esteem2jra3 ECASJO_; | Approved | Most recent IF: 2.843; 2015 IF: 2.436 | ||
Call Number | c:irua:121405 c:irua:121405UA @ admin @ c:irua:121405 | Serial | 2731 | ||
Permanent link to this record | |||||
Author | Martinez, G.T.; Jones, L.; de Backer, A.; Béché, A.; Verbeeck, J.; Van Aert, S.; Nellist, P.D. | ||||
Title | Quantitative STEM normalisation : the importance of the electron flux | Type | A1 Journal article | ||
Year | 2015 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 159 | Issue | 159 | Pages | 46-58 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Annular dark-field (ADF) scanning transmission electron microscopy (STEM) has become widely used in quantitative studies based on the opportunity to directly compare experimental and simulated images. This comparison merely requires the experimental data to be normalised and expressed in units of fractional beam-current. However, inhomogeneities in the response of electron detectors can complicate this normalisation. The quantification procedure becomes both experiment and instrument specific, requiring new simulations for the particular response of each instrument's detector, and for every camera-length used. This not only impedes the comparison between different instruments and research groups, but can also be computationally very time consuming. Furthermore, not all image simulation methods allow for the inclusion of an inhomogeneous detector response. In this work, we propose an alternative method for normalising experimental data in order to compare these with simulations that consider a homogeneous detector response. To achieve this, we determine the electron flux distribution reaching the detector by means of a camera-length series or a so-called atomic column cross-section averaged convergent beam electron diffraction (XSACBED) pattern. The result is then used to determine the relative weighting of the detector response. Here we show that the results obtained by this new electron flux weighted (EFW) method are comparable to the currently used method, while considerably simplifying the needed simulation libraries. The proposed method also allows one to obtain a metric that describes the quality of the detector response in comparison with the ideal detector response. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000366220000006 | Publication Date | 2015-08-01 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 27 | Open Access | |
Notes | 246791 Countatoms; 278510 Vortex; 312483 Esteem2; Fwo G036815; G036915; G037413; G004413; esteem2ta ECASJO; | Approved | Most recent IF: 2.843; 2015 IF: 2.436 | ||
Call Number | c:irua:127293 c:irua:127293UA @ admin @ c:irua:127293 | Serial | 2762 | ||
Permanent link to this record | |||||
Author | Béché, A.; Rouviere, J.L.; Barnes, J.P.; Cooper, D. | ||||
Title | Strain measurement at the nanoscale : comparison between convergent beam electron diffraction, nano-beam electron diffraction, high resolution imaging and dark field electron holography | Type | A1 Journal article | ||
Year | 2013 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 131 | Issue | Pages | 10-23 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Convergent beam electron diffraction (CBED), nano-beam electron diffraction (NBED or NBD), high resolution imaging (HRTEM and HRSTEM) and dark field electron holography (DFEH or HoloDark) are five TEM based techniques able to quantitatively measure strain at the nanometer scale. In order to demonstrate the advantages and disadvantages of each technique, two samples composed of epitaxial silicon-germanium layers embedded in a silicon matrix have been investigated. The five techniques are then compared in terms of strain precision and accuracy, spatial resolution, field of view, mapping abilities and ease of performance and analysis. (C) 2013 Elsevier By. All rights reserved. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000322631200002 | Publication Date | 2013-04-06 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 73 | Open Access | |
Notes | Approved | Most recent IF: 2.843; 2013 IF: 2.745 | |||
Call Number | UA @ lucian @ c:irua:109774 | Serial | 3171 | ||
Permanent link to this record | |||||
Author | Béché, A.; Juchtmans, R.; Verbeeck, J. | ||||
Title | Efficient creation of electron vortex beams for high resolution STEM imaging | Type | A1 Journal article | ||
Year | 2017 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 178 | Issue | 178 | Pages | 12-19 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | The recent discovery of electron vortex beams carrying quantised angular momentum in the TEM has led to an active field of research, exploring a variety of potential applications including the possibility of mapping magnetic states at the atomic scale. A prerequisite for this is the availability of atomic sized electron vortex beams at high beam current and mode purity. In this paper we present recent progress showing that by making use of the Aharonov-Bohm effect near the tip of a long single domain ferromagnetic Nickel needle, a very efficient aperture for the production of electron vortex beams can be realised. The aperture transmits more than 99% of all electrons and provides a vortex mode purity of up to 92%. Placing this aperture in the condenser plane of a state of the art Cs corrected microscope allows us to demonstrate atomic resolution HAADF STEM images with spatial resolution better than 1 Angstrom, in agreement with theoretical expectations and only slightly inferior to the performance of a non-vortex probe on the same instrument. | ||||
Address | EMAT, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium | ||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | English | Wos | 000403862900003 | Publication Date | 2016-05-10 |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 30 | Open Access | OpenAccess |
Notes | A.B. and J.V. acknowledge funding from the European Research Council under the 7th Framework Program (FP7), ERC Starting Grant No. 278510 VORTEX. J.V. acknowledges funding from FWO project G.0044.13N ('Charge ordering').; ECASJO_; | Approved | Most recent IF: 2.843 | ||
Call Number | c:irua:134085 c:irua:134085UA @ admin @ c:irua:134085 | Serial | 4094 | ||
Permanent link to this record | |||||
Author | Muller-Caspary, K.; Krause, F.F.; Grieb, T.; Loffler, S.; Schowalter, M.; Béché, A.; Galioit, V.; Marquardt, D.; Zweck, J.; Schattschneider, P.; Verbeeck, J.; Rosenauer, A. | ||||
Title | Measurement of atomic electric fields and charge densities from average momentum transfers using scanning transmission electron microscopy | Type | A1 Journal article | ||
Year | 2016 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 178 | Issue | 178 | Pages | 62-80 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | This study sheds light on the prerequisites, possibilities, limitations and interpretation of high-resolution differential phase contrast (DPC) imaging in scanning transmission electron microscopy (STEM). We draw particular attention to the well-established DPC technique based on segmented annular detectors and its relation to recent developments based on pixelated detectors. These employ the expectation value of the momentum transfer as a reliable measure of the angular deflection of the STEM beam induced by an electric field in the specimen. The influence of scattering and propagation of electrons within the specimen is initially discussed separately and then treated in terms of a two-state channeling theory. A detailed simulation study of GaN is presented as a function of specimen thickness and bonding. It is found that bonding effects are rather detectable implicitly, e.g., by characteristics of the momentum flux in areas between the atoms than by directly mapping electric fields and charge densities. For strontium titanate, experimental charge densities are compared with simulations and discussed with respect to experimental artifacts such as scan noise. Finally, we consider practical issues such as figures of merit for spatial and momentum resolution, minimum electron dose, and the mapping of larger-scale, built-in electric fields by virtue of data averaged over a crystal unit cell. We find that the latter is possible for crystals with an inversion center. Concerning the optimal detector design, this study indicates that a sampling of 5mrad per pixel is sufficient in typical applications, corresponding to approximately 10x10 available pixels. | ||||
Address | Institut fur Festkr perphysik, Universitat Bremen, Otto-Hahn-Allee 1, 28359 Bremen, Germany | ||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | English | Wos | 000403862900009 | Publication Date | 2016-05-12 |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 93 | Open Access | |
Notes | K.M.-C. acknowledges support from the Deutsche Forschungsgemeinschaft (DFG) under contract MU3660/1-1. This work was further supported by the DFG under contract RO2057/4-2 and O2057/11-1. J.V. and A.B. acknowledge funding from the European Research Council (ERC) under the 7th Framework Program (FP7), and ERC Starting Grant No. 278510-VORTEX. Experimental results are obtained on the Qu-Ant-EM microscope partly funded by the Hercules fund from the Flemish government. J.V. also acknowledges funding through a GOA project “Solarpaint” of the University of Antwerp. SL and PS acknowledge financial support by the Austrian Science Fund (FWF) under grants No. I543-N20 and J3732-N27. ECASJO_; | Approved | Most recent IF: 2.843 | ||
Call Number | c:irua:134125UA @ admin @ c:irua:134125 | Serial | 4098 | ||
Permanent link to this record | |||||
Author | van den Bos, K.H.W.; Krause, F.F.; Béché, A.; Verbeeck, J.; Rosenauer, A.; Van Aert, S. | ||||
Title | Locating light and heavy atomic column positions with picometer precision using ISTEM | Type | A1 Journal article | ||
Year | 2016 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 172 | Issue | 172 | Pages | 75-81 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Recently, imaging scanning transmission electron microscopy (ISTEM) has been proposed as a promising new technique combining the advantages of conventional TEM (CTEM) and STEM [1]. The ability to visualize light and heavy elements together makes it a particularly interesting new, spatially incoherent imaging mode. Here, we evaluate this technique in term of precision with which atomic column locations can be measured. By using statistical parameter estimation theory, we will show that these locations can be accurately measured with a precision in the picometer range. Furthermore, a quantitative comparison is made with HAADF STEM imaging to investigate the advantages of ISTEM. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000390600200009 | Publication Date | 2016-10-09 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 8 | Open Access | |
Notes | The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through project fundings (G.0374.13N, G.0368.15N, G.0369.15N), and by a Ph.D. grant to K.H.W. van den Bos. The research leading to these results has received funding from the Deutsche Forschungsgemeinschaft under Contract No. RO 2057/4-2 and the European Union Seventh Framework Programme under Grant Agreement 312483 – ESTEEM2. We thank Prof. G. Koster from the University of Twente for kindly providing us with the PbTiO3 test sample. | Approved | Most recent IF: 2.843 | ||
Call Number | EMAT @ emat @ c:irua:136109UA @ admin @ c:irua:136109 | Serial | 4288 | ||
Permanent link to this record | |||||
Author | Béché, A.; Rouvière, J.L.; Barnes, J.P.; Cooper, D. | ||||
Title | Dark field electron holography for strain measurement | Type | A1 Journal article | ||
Year | 2011 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 111 | Issue | 3 | Pages | 227-238 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Dark field electron holography is a new TEM-based technique for measuring strain with nanometer scale resolution. Here we present the procedure to align a transmission electron microscope and obtain dark field holograms as well as the theoretical background necessary to reconstruct strain maps from holograms. A series of experimental parameters such as biprism voltage, sample thickness, exposure time, tilt angle and choice of diffracted beam are then investigated on a silicon-germanium layer epitaxially embedded in a silicon matrix in order to obtain optimal dark field holograms over a large field of view with good spatial resolution and strain sensitivity. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000288638200007 | Publication Date | 2010-12-01 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 31 | Open Access | |
Notes | Approved | Most recent IF: 2.843; 2011 IF: 2.471 | |||
Call Number | UA @ lucian @ c:irua:136368 | Serial | 4496 | ||
Permanent link to this record | |||||
Author | Gauquelin, N.; van den Bos, K.H.W.; Béché, A.; Krause, F.F.; Lobato, I.; Lazar, S.; Rosenauer, A.; Van Aert, S.; Verbeeck, J. | ||||
Title | Determining oxygen relaxations at an interface: A comparative study between transmission electron microscopy techniques | Type | A1 Journal article | ||
Year | 2017 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 181 | Issue | 181 | Pages | 178-190 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Nowadays, aberration corrected transmission electron microscopy (TEM) is a popular method to characterise nanomaterials at the atomic scale. Here, atomically resolved images of nanomaterials are acquired, where the contrast depends on the illumination, imaging and detector conditions of the microscope. Visualization of light elements is possible when using low angle annular dark field (LAADF) STEM, annular bright field (ABF) STEM, integrated differential phase contrast (iDPC) STEM, negative spherical aberration imaging (NCSI) and imaging STEM (ISTEM). In this work, images of a NdGaO3-La0.67Sr0.33MnO3 (NGO-LSMO) interface are quantitatively evaluated by using statistical parameter estimation theory. For imaging light elements, all techniques are providing reliable results, while the techniques based on interference contrast, NCSI and ISTEM, are less robust in terms of accuracy for extracting heavy column locations. In term of precision, sample drift and scan distortions mainly limits the STEM based techniques as compared to NCSI. Post processing techniques can, however, partially compensate for this. In order to provide an outlook to the future, simulated images of NGO, in which the unavoidable presence of Poisson noise is taken into account, are used to determine the ultimate precision. In this future counting noise limited scenario, NCSI and ISTEM imaging will provide more precise values as compared to the other techniques, which can be related to the mechanisms behind the image recording. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000411170800022 | Publication Date | 2017-06-03 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 34 | Open Access | OpenAccess |
Notes | The authors acknowledge financial support from Flanders (FWO, Belgium) through project fundings (G.0044.13N, G.0374.13N, G.0368.15N, G.0369.15N), and by a Ph.D. grant to K.H.W.v.d.B. The Qu-Ant-EM microscope used for this study was partly funded by the Hercules fund from the Flemish Government. A.B. and N.G. acknowledge the EUROTAPES project (FP7-NMP.2011.2.2-1 Grant no.280432) which partly funded this study. N.G., A.B. and J.V. acknowledge funding from the European Research Council under the 7th Framework Program (FP7), ERC Starting Grant 278510 VORTEX. The research leading to these results has received funding from the Deutsche Forschungsgemeinschaft under Contract No. RO 2057/4-2 and the European Union Seventh Framework Programme under Grant Agreement 312483 – ESTEEM2. We thank Prof. G. Koster from the University of Twente for kindly providing us with the LSMO-NGO test sample. | Approved | Most recent IF: 2.843 | ||
Call Number | EMAT @ emat @ c:irua:144435UA @ admin @ c:irua:144435 | Serial | 4620 | ||
Permanent link to this record | |||||
Author | Verbeeck, J.; Béché, A.; Müller-Caspary, K.; Guzzinati, G.; Luong, M.A.; Den Hertog, M. | ||||
Title | Demonstration of a 2 × 2 programmable phase plate for electrons | Type | A1 Journal article | ||
Year | 2018 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 190 | Issue | Pages | 58-65 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | First results on the experimental realisation of a 2 × 2 programmable phase plate for electrons are presented. The design consists of an array of electrostatic elements that influence the phase of electron waves passing through 4 separately controllable aperture holes. This functionality is demonstrated in a conventional transmission electron microscope operating at 300 kV and results are in very close agreement with theoretical predictions. The dynamic creation of a set of electron probes with different phase symmetry is demonstrated, thereby bringing adaptive optics in TEM one step closer to reality. The limitations of the current design and how to overcome these in the future are discussed. Simulations show how further evolved versions of the current proof of concept might open new and exciting application prospects for beam shaping and aberration correction. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000432868800007 | Publication Date | 2018-04-18 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 73 | Open Access | Not_Open_Access: Available from 19.04.2020 |
Notes | J.V. and A.B. acknowledge funding from the Fund for Scientific Research Flanders FWO project G093417N and the European Research Council under the 7th Framework Program (FP7), ERC Starting Grant 278510 VORTEX and ERC proof of concept project DLV-789598 ADAPTEM. The Qu-Ant-EM microscope used in this work was partly funded by the Hercules fund from the Flemish Government. MdH acknowledges financial support from the ANRCOSMOS (ANR-12-JS10-0002). MdH and ML acknowledge funding from the Laboratoire d’excellence LANEF in Grenoble (ANR-10-LABX-51-01). | Approved | Most recent IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:150459UA @ admin @ c:irua:150459 | Serial | 4920 | ||
Permanent link to this record | |||||
Author | Müller-Caspary, K.; Krause, F.F.; Winkler, F.; Béché, A.; Verbeeck, J.; Van Aert, S.; Rosenauer, A. | ||||
Title | Comparison of first moment STEM with conventional differential phase contrast and the dependence on electron dose | Type | A1 Journal article | ||
Year | 2019 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 203 | Issue | 203 | Pages | 95-104 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | This study addresses the comparison of scanning transmission electron microscopy (STEM) measurements of momentum transfers using the first moment approach and the established method that uses segmented annular detectors. Using an ultrafast pixelated detector to acquire four-dimensional, momentum-resolved STEM signals, both the first moment calculation and the calculation of the differential phase contrast (DPC) signals are done for the same experimental data. In particular, we investigate the ability to correct the segment-based signal to yield a suitable approximation of the first moment for cases beyond the weak phase object approximation. It is found that the measurement of momentum transfers using segmented detectors can approach the first moment measurement as close as 0.13 h/nm in terms of a root mean square (rms) difference in 10 nm thick SrTiO3 for a detector with 16 segments. This amounts to 35% of the rms of the momentum transfers. In addition, we present a statistical analysis of the precision of first moment STEM as a function of dose. For typical experimental settings with recent hardware such as a Medipix3 Merlin camera attached to a probe-corrected STEM, we find that the precision of the measurement of momentum transfers stagnates above certain doses. This means that other instabilities such as specimen drift or scan noise have to be taken into account seriously for measurements that target, e.g., the detection of bonding effects in the charge density. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000465021000013 | Publication Date | 2018-12-30 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 25 | Open Access | OpenAccess |
Notes | ; The direct electron detector (Medipix3 Merlin) was funded by the Hercules fund from the Flemish Government. K. Muller-Caspary acknowledges funding from the Initiative and Network Fund of the Helmholtz Association within the framework of the Helmholtz Young Investigator Group moreSTEM (VH-NG-1317) at Forschungszentrum Julich, Germany. F. F. Krause acknowledges funding from the Central Research Development Fund of the University of Bremen, Germany. This project has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (Grant Agreement No. 770887). The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) and the Research Fund of the University of Antwerp. ; | Approved | Most recent IF: 2.843 | ||
Call Number | UA @ admin @ c:irua:160213 | Serial | 5242 | ||
Permanent link to this record | |||||
Author | Vanrompay, H.; Skorikov, A.; Bladt, E.; Béché, A.; Freitag, B.; Verbeeck, J.; Bals, S. | ||||
Title | Fast versus conventional HAADF-STEM tomography of nanoparticles: advantages and challenges | Type | A1 Journal article | ||
Year | 2021 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 221 | Issue | Pages | 113191 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | HAADF-STEM tomography is a widely used experimental technique for analyzing nanometer-scale crystalline structures of a large variety of materials in three dimensions. Unfortunately, the acquisition of conventional HAADF-STEM tilt series can easily take up one hour or more, depending on the complexity of the experiment. It is therefore far from straightforward to investigate samples that do not withstand long acquisition or to acquire large amounts of tilt series during a single TEM experiment. The latter would lead to the ability to obtain statistically meaningful 3D data, or to perform in situ 3D characterizations with a much shorter time resolution. Various HAADF-STEM acquisition strategies have been proposed to accelerate the tomographic acquisition and reduce the required electron dose. These methods include tilting the holder continuously while acquiring a projection “movie” and a hybrid, incremental, methodology which combines the benefits of the conventional and continuous technique. However, until now an experimental evaluation has been lacking. In this paper, the different acquisition strategies will be experimentally compared in terms of speed, resolution and electron dose. This evaluation will be performed based on experimental tilt series acquired for various metallic nanoparticles with different shapes and sizes. We discuss the data processing involved with the fast HAADF-STEM tilt series and provide a general guideline when which acquisition strategy should be preferentially used. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000612539600003 | Publication Date | 2020-12-08 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 15 | Open Access | OpenAccess |
Notes | We acknowledge Prof. Luis M. Liz-Marzán and co-workers of the Bionanoplasmonics Laboratory, CIC biomaGUNE, Spain for providing the Au@Ag nanoparticles, Prof. Sara. E. Skrabalak and co-workers of Indiana University, United States for the provision of the Au octopods and Prof. Teri W. Odom of Northwestern University, United States for the provision of the Au nanostars. H.V. acknowledges financial support by the Research Foundation Flanders (FWO grant 1S32617N). S.B acknowledges financial support by the Research Foundation Flanders (FWO grant G.0381.16N). This project received funding as well from the European Union’s Horizon 2020 research and innovation program under grant agreement No 731019 (EUSMI) and No 815128 (REALNANO). The authors acknowledge the entire EMAT technical staff for their support.; sygma | Approved | Most recent IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:174551 | Serial | 6660 | ||
Permanent link to this record | |||||
Author | Vega Ibañez, F.; Béché, A.; Verbeeck, J. | ||||
Title | Can a programmable phase plate serve as an aberration corrector in the transmission electron microscope (TEM)? | Type | A1 Journal article | ||
Year | 2022 | Publication | Microscopy and microanalysis | Abbreviated Journal | Microsc Microanal |
Volume | Issue | Pages | Pii S1431927622012260-10 | ||
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Current progress in programmable electrostatic phase plates raises questions about their usefulness for specific applications. Here, we explore different designs for such phase plates with the specific goal of correcting spherical aberration in the transmission electron microscope (TEM). We numerically investigate whether a phase plate could provide down to 1 angstrom ngstrom spatial resolution on a conventional uncorrected TEM. Different design aspects (fill factor, pixel pattern, symmetry) were evaluated to understand their effect on the electron probe size and current density. Some proposed designs show a probe size () down to 0.66 angstrom, proving that it should be possible to correct spherical aberration well past the 1 angstrom limit using a programmable phase plate consisting of an array of electrostatic phase-shifting elements. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000849975400001 | Publication Date | 2022-09-21 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 1431-9276 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.8 | Times cited | 3 | Open Access | OpenAccess |
Notes | All authors acknowledge funding from the Flemish Research Fund under contract G042820N “Exploring adaptive optics in transmission electron microscopy”. J.V. acknowledges funding from the European Union’s Horizon 2020 Research Infrastructure – Integrating Activities for Advanced Communities under grant agreement No 823717 – ESTEEM3 and from the University of Antwerp through a TOP BOF project.; esteem3reported; esteem3jra | Approved | Most recent IF: 2.8 | ||
Call Number | UA @ admin @ c:irua:190627 | Serial | 7134 | ||
Permanent link to this record | |||||
Author | Denneulin, T.; Rouvière, J.L.; Béché, A.; Py, M.; Barnes, J.P.; Rochat, N.; Hartmann, J.M.; Cooper, D. | ||||
Title | The reduction of the substitutional C content in annealed Si/SiGeC superlattices studied by dark-field electron holography | Type | A1 Journal article | ||
Year | 2011 | Publication | Semiconductor science and technology | Abbreviated Journal | Semicond Sci Tech |
Volume | 26 | Issue | 12 | Pages | 1-10 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Si/Si(1 − x − y)GexCy superlattices are used in the construction of new microelectronic architectures such as multichannel transistors. The introduction of carbon in SiGe allows for compensation of the strain and to avoid plastic relaxation. However, the formation of incoherent β-SiC clusters during annealing limits the processability of SiGeC. This precipitation leads to a modification of the strain in the alloy due to the reduction of the substitutional carbon content. Here, we investigated the strain in annealed Si/Si0.744Ge0.244C0.012 superlattices grown by reduced pressure chemical vapour deposition using dark-field electron holography. The variation of the substitutional C content was calculated by correlating the results with finite-element simulations. The obtained values were then compared with Fourier-transformed infrared spectrometry measurements. It was shown that after annealing for 2 min at 1050 °C carbon no longer has any influence on strain in the superlattice, which behaves like pure SiGe. However, a significant proportion of substitutional C atoms remain in a third-nearest neighbour (3nn) configuration. It was deduced that the influence of 3nn C on strain is negligible and that only isolated atoms have a significant contribution. It was also proposed that the 3nn configuration is an intermediary step during the formation of SiC clusters. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | London | Editor | ||
Language | Wos | 000300151300010 | Publication Date | 2011-11-07 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0268-1242 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.305 | Times cited | Open Access | ||
Notes | Approved | Most recent IF: 2.305; 2011 IF: 1.723 | |||
Call Number | UA @ lucian @ c:irua:136427 | Serial | 4508 | ||
Permanent link to this record | |||||
Author | Prabhakara, V.; Jannis, D.; Béché, A.; Bender, H.; Verbeeck, J. | ||||
Title | Strain measurement in semiconductor FinFET devices using a novel moiré demodulation technique | Type | A1 Journal article | ||
Year | 2019 | Publication | Semiconductor science and technology | Abbreviated Journal | Semicond Sci Tech |
Volume | Issue | Pages | |||
Keywords | A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT) | ||||
Abstract | Moiré fringes are used throughout a wide variety of applications in physics and engineering to bring out small variations in an underlying lattice by comparing with another reference lattice. This method was recently demonstrated in Scanning Transmission Electron Microscopy imaging to provide local strain measurement in crystals by comparing the crystal lattice with the scanning raster that then serves as the reference. The images obtained in this way contain a beating fringe pattern with a local period that represents the deviation of the lattice from the reference. In order to obtain the actual strain value, a region containing a full period of the fringe is required, which results in a compromise between strain sensitivity and spatial resolution. In this paper we propose an advanced setup making use of an optimised scanning pattern and a novel phase stepping demodulation scheme. We demonstrate the novel method on a series of 16 nm Si-Ge semiconductor FinFET devices in which strain plays a crucial role in modulating the charge carrier mobility. The obtained results are compared with both Nano-beam diffraction and the recently proposed Bessel beam diffraction technique. The setup provides a much improved spatial resolution over conventional moiré imaging in STEM while at the same time being fast and requiring no specialised diffraction camera as opposed to the diffraction techniques we compare to. |
||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000537721200002 | Publication Date | 2019-11-29 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0268-1242 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.305 | Times cited | 8 | Open Access | |
Notes | The Qu-Ant-EM microscope and the direct electron detector used in the diffraction experiments was partly funded by the Hercules fund from the Flemish Government. This project has received funding from the GOA project “Solarpaint” of the University of Antwerp. We would also like to thank Dr. Thomas Nuytten and Prof. Dr. Wilfried Vandervorst from IMEC, Leuven for their continuous support and collaboration with the project. | Approved | Most recent IF: 2.305 | ||
Call Number | EMAT @ emat @c:irua:165794 | Serial | 5445 | ||
Permanent link to this record | |||||
Author | Velazco, A.; Nord, M.; Béché, A.; Verbeeck, J. | ||||
Title | Evaluation of different rectangular scan strategies for STEM imaging | Type | A1 Journal article | ||
Year | 2020 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | Issue | Pages | 113021 | ||
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | STEM imaging is typically performed by raster scanning a focused electron probe over a sample. Here we investigate and compare three different scan patterns, making use of a programmable scan engine that allows to arbitrarily set the sequence of probe positions that are consecutively visited on the sample. We compare the typical raster scan with a so-called ‘snake’ pattern where the scan direction is reversed after each row and a novel Hilbert scan pattern that changes scan direction rapidly and provides an homogeneous treatment of both scan directions. We experimentally evaluate the imaging performance on a single crystal test sample by varying dwell time and evaluating behaviour with respect to sample drift. We demonstrate the ability of the Hilbert scan pattern to more faithfully represent the high frequency content of the image in the presence of sample drift. It is also shown that Hilbert scanning provides reduced bias when measuring lattice parameters from the obtained scanned images while maintaining similar precision in both scan directions which is especially important when e.g. performing strain analysis. Compared to raster scanning with flyback correction, both snake and Hilbert scanning benefit from dose reduction as only small probe movement steps occur. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000544042800007 | Publication Date | 2020-05-21 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.2 | Times cited | 13 | Open Access | OpenAccess |
Notes | A.V., A.B. and J.V. acknowledge funding through FWO project G093417N ('Compressed sensing enabling low dose imaging in transmission electron microscopy') from the Flanders Research Fund. M.N. received support for this work from the European Union's Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement No 838001. J.V acknowledges funding from the European Union's Horizon 2020 research and innovation programme under grant agreement No 823717 – ESTEEM3. | Approved | Most recent IF: 2.2; 2020 IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:169225 | Serial | 6369 | ||
Permanent link to this record |