|
“Impact of the Particle Diameter on Ion Cloud Formation from Gold Nanoparticles in ICPMS”. Fuchs J, Aghaei M, Schachel TD, Sperling M, Bogaerts A, Karst U, Analytical chemistry 90, 10271 (2018). http://doi.org/10.1021/acs.analchem.8b02007
Abstract: The unique capabilities of microsecond dwell time (DT) single-particle inductively coupled plasma mass spectrometry (spICPMS) were utilized to characterize the cloud of ions generated from the introduction of suspensions of gold nanoparticles (AuNPs) into the plasma. A set of narrowly distributed particles with diameters ranging from 15.4 to 100.1 nm was synthesized and characterized according to established protocols. Statistically significant numbers of the short transient spICPMS events were evaluated by using 50 μs DT for their summed intensity, maximum intensity, and duration, of which all three were found to depend on the particle diameter. The summed intensity increases from 10 to 1661 counts and the maximum intensity from 6 to 309 counts for AuNPs with diameters from 15.4 to 83.2 nm. The event duration rises from 322 to 1007 μs upon increasing AuNP diameter. These numbers represent a comprehensive set of key data points of the ion clouds generated in ICPMS from AuNPs. The extension of event duration is of high interest to appoint the maximum possible particle number concentration at which separation of consecutive events in spICPMS can still be achieved. Moreover, the combined evaluation of all above-mentioned ion cloud characteristics can explain the regularly observed prolonged single-particle events. The transport and ionization behavior of AuNPs in the ICP was also computationally modeled to gain insight into the size-dependent signal generation. The simulated data reveals that the plasma temperature, and therefore the point of ionization of the particles, is the same for all diameters. However, the maximum number density of Au+, as well as the extent of the ion cloud, depends on the particle diameter, in agreement with the experimental data, and it provides an adequate explanation for the observed ion cloud characteristics.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 5
DOI: 10.1021/acs.analchem.8b02007
|
|
|
“Recent trends in solids mass spectrometry: GDMS and other methods”. Gijbels R, Bogaerts A, Fresenius' journal of analytical chemistry 359, 326 (1997). http://doi.org/10.1007/s002160050581
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 5
DOI: 10.1007/s002160050581
|
|
|
“Direct sensing of superoxide and its relatives reactive oxygen and nitrogen species in phosphate buffers during cold atmospheric plasmas exposures”. Girard-Sahun F, Lefrancois P, Badets V, Arbault S, Clement F, Analytical Chemistry 94, 5555 (2022). http://doi.org/10.1021/ACS.ANALCHEM.1C04998
Abstract: This study aims at sensing in situ reactive oxygen and nitrogen species (RONS) and specifically superoxide anion (O-2(center dot-)) in aqueous buffer solutions exposed to cold atmospheric plasmas (CAPs). CAPs were generated by ionizing He gas shielded with variable N-2/O-2 mixtures. Thanks to ultramicroelectrodes protected against the high electric fields transported by the ionization waves of CAPs, the production of superoxide and several RONS was electrochemically directly detected in liquids during their plasma exposure. Complementarily, optical emissive spectroscopy (OES) was used to study the plasma phase composition and its correlation with the chemistry in the exposed liquid. The specific production of O-2(center dot-), a biologically reactive redox species, was analyzed by cyclic voltammetry (CV), in both alkaline (pH 11), where the species is fairly stable, and physiological (pH 7.4) conditions, where it is unstable. To understand its generation with respect to the plasma chemistry, we varied the shielding gas composition of CAPs to directly impact on the RONS composition at the plasma-liquid interface. We observed that the production and accumulation of RONS in liquids, including O(2)(center dot-)depends on the plasma composition, with N-2-based shieldings providing the highest superoxide concentrations (few 10s of micromolar at most) and of its derivatives (hundreds of micromolar). In situ spectroscopic and electrochemical analyses provide a high resolution kinetic and quantitative understanding of the interactions between CAPs and physiological solutions for biomedical applications.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 7.4
DOI: 10.1021/ACS.ANALCHEM.1C04998
|
|
|
“A microanalytical study of the gills of aluminium-exposed rainbow trout (Salmo gairdneri)”. Goossenaerts C, Van Grieken R, Jacob W, Witters H, Vanderborght O, International journal of environmental analytical chemistry 34, 227 (1988). http://doi.org/10.1080/03067319808026840
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067319808026840
|
|
|
“Analysis of Short-Lived Reactive Species in Plasma–Air–Water Systems: The Dos and the Do Nots”. Gorbanev Y, Privat-Maldonado A, Bogaerts A, Analytical Chemistry 90, 13151 (2018). http://doi.org/10.1021/acs.analchem.8b03336
Abstract: This Feature addresses the analysis of the reactive species generated by nonthermal atmospheric
pressure plasmas, which are widely employed in industrial and biomedical research, as well as first
clinical applications. We summarize the progress in detection of plasma-generated short-lived
reactive oxygen and nitrogen species in aqueous solutions, discuss the potential and limitations of
various analytical methods in plasma−liquid systems, and provide an outlook on the possible future
research goals in development of short-lived reactive species analysis methods for a general
nonspecialist audience.
Keywords: A1 Journal Article; Plasma, laser ablation and surface modeling Antwerp (PLASMANT) ;
Impact Factor: 6.32
Times cited: 17
DOI: 10.1021/acs.analchem.8b03336
|
|
|
“Automated particle analysis of populations of silver halide microcrystals by electron probe microanalysis under cryogenic conditions”. Gregory CL, Nullens HA, Gijbels RH, van Espen PJ, Geuens I, de Keyzer R, Analytical chemistry 70, 2551 (1998). http://doi.org/10.1021/ac9710644
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Chemometrics (Mitac 3)
Impact Factor: 6.32
Times cited: 12
DOI: 10.1021/ac9710644
|
|
|
“Fast heating induced impulse halogenation of refractory sample components in electrothermal atomic absorption spectrometry by direct injection of a liquid halogenating agent”. György K, Ajtony Z, van Meel K, Van Grieken R, Czitrovszky A, Bencs L, Talanta : the international journal of pure and applied analytical chemistry 85, 1253 (2011). http://doi.org/10.1016/J.TALANTA.2011.05.028
Abstract: A novel electrothermal atomic absorption spectrometry (ETAAS) method was developed for the halogenation of refractory sample components (Er, Nd and Nb) of lithium niobate (LiNbO3) and bismuth tellurite (Bi2TeO5) optical single crystals to overcome memory effects and carry-over. For this purpose, the cleaning step of a regular graphite furnace heating program was replaced with a halogenation cycle. In this cycle, after the graphite tube cooled to room temperature, a 20 μL aliquot of liquid carbon tetrachloride (CCl4) was dispensed with a conventional autosampler into the graphite tube. The CCl4 was partially dried at 80 °C under the mini-flow (40 cm3 min−1) condition of the Ar internal furnace gas (IFG), then the residue was decomposed (pyrolyzed) by fast furnace heating at 19002100 °C under interrupted flow of the IFG. This step was followed by a clean-out stage at 2100 °C under the maximum flow of the IFG. The advantage of the present method is that it does not require any alteration to the graphite furnace gas supply system in contrast to most of the formerly introduced halogenation techniques. The effectiveness of the halogenation method was verified with the determination of Er and Nd dopants in the optical crystals. In these analyses, a sensitivity decrease was observed, which was likely due to the enhanced deterioration of the graphite tube surface. Therefore, the application of mathematical correction (resloping) of the calibration was also required. The calibration curves were linear up to 1.5 and 10 μmol L−1 for Er and Nd, respectively. Characteristic masses of 18 and 241 pg and the limit of detection (LOD) values of 0.017 and 0.27 μmol L−1 were found for Er and Nd, respectively. These LOD data correspond to 0.68 μmol mol−1 Er and 11 μmol mol−1 Nd in solid bismuth tellurite samples. The analytical results were compared with those obtained by a conventional ETAAS method and validated with X-ray fluorescence spectrometry analysis.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.TALANTA.2011.05.028
|
|
|
“Concentration related response potentiometric titrations to study the interaction of small molecules with large biomolecules”. Hamidi-Asl E, Daems D, De Wael K, Van Camp G, Nagels LJ, Analytical chemistry 86, 12243 (2014). http://doi.org/10.1021/AC503385X
Abstract: In the present article, the utility of a special potentiometric titration approach for recognition and calculation of biomolecule/small molecule interactions is reported. This approach is fast, sensitive, reproducible and inexpensive in comparison to the other methods for the determination of the association constant values (Ka) and the interaction energies (ΔG). The potentiometric titration measurement is based on the use of a classical polymeric membrane indicator electrode in a solution of the small molecule ligand. The biomolecule is used as a titrant. The potential is measured versus a reference electrode and transformed to a concentration related signal over the entire concentration interval, also at low concentrations, where the mV (y-axis) versus logcanalyte (x-axis) potentiometric calibration curve is not linear. In the procedure, the Ka is calculated for the interaction of cocaine with a cocaine binding aptamer and with an anti-cocaine antibody. To study the selectivity and cross-reactivity, other oligonucleotides and aptamers are tested, as well as other small ligand molecules such as tetrakis (4-chlorophenyl)borate, metergoline, lidocaine, and bromhexine. The calculated Ka compared favorably to the value reported in the literature using SPR. The potentiometric titration approach called Concentration related Response Potentiometry, is used to study molecular interaction for 7 macromolecular target molecules and 4 small molecule ligands.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 10
DOI: 10.1021/AC503385X
|
|
|
“Concentration profiles of metal contaminants in fluvial sediments of a rural-urban drainage basin in Tanzania”. Hellar-Kihampa H, Potgieter-Vermaak S, De Wael K, Lugwisha E, van Espen P, Van Grieken R, International journal of environmental analytical chemistry 94, 77 (2014). http://doi.org/10.1080/03067319.2013.791976
Abstract: This study investigated concentration profiles of trace, rare earth and platinum group metals in fluvial sediments from the Pangani river basin (43,650 km2), one of the largest river basins in Tanzania, to assess its environmental quality. Sediment samples were collected in two distinct seasons from 12 representative sites of diverse land-use practices and characterised by ICP-MS after optimised microwave digestion. Ecological risks were assessed by evaluation of pollution index and comparison with legislated sediment quality guidelines (SQG). The results revealed contamination by some trace metals (e.g. Pb, V, Cu, Cr, Ni, Cd, As, Co, Mn and Zn) in concentrations ranging from 0.7 to 2940 mg kg−1, and four rare earth elements (Y, Ce, Nd, Yb) in concentrations ranging from 0.9 (Yb) to 500 mg kg−1 dry weight (Ce), which significantly exceeded the estimated background values at some stations. Palladium was the only platinum group element that was detected in quantifiable concentrations (0.33.5 mg kg−1). Concentrations of some trace metals exceeded the SQGs at some localised areas. Principal component analysis and multivariate correlations indicated geochemical characteristics of the area as the major control of metal concentrations and spatial variability. Organic matter and clay contents also played a significant role in metal distributions. Assessment of land-use practices upstream of the sampling locations was used to trace potential anthropogenic sources of metal enrichments, where highest levels were found in areas close to urban centres and agricultural activities. The study provides baseline data for future monitoring programs, and highlights the need for more comprehensive analysis involving a wider spatio-temporal scale and ecotoxicological risk assessment.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.208
Times cited: 5
DOI: 10.1080/03067319.2013.791976
|
|
|
“Performance of total reflection and grazing emission X-ray fluorescence spectrometry for the determination of trace metals in drinking water in relation to other analytical techniques”. Hołynska B, Olko M, Ostachowicz B, Ostachowicz J, Wegrzynek D, Claes M, Van Grieken R, de Bokx P, Kump P, Necemer M, Fresenius' journal of analytical chemistry 362, 294 (1998). http://doi.org/10.1007/S002160051077
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S002160051077
|
|
|
“Airborne particles in the Miyagi Museum of Art in Sendai, Japan, studied by electron probe X-ray microanalysis and energy dispersive X-ray fluorescence analysis”. Injuk J, Osán J, Van Grieken R, Tsuji K, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 18, 561 (2002). http://doi.org/10.2116/ANALSCI.18.561
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.2116/ANALSCI.18.561
|
|
|
“Applications of micro-analysis to individual environmental particles”. Jambers W, de Bock L, Van Grieken R, Fresenius' journal of analytical chemistry 355, 521 (1996). http://doi.org/10.1007/S0021663550521
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S0021663550521
|
|
|
“Present and future applications of beam techniques in environmental microanalysis”. Jambers W, Van Grieken R, Trends in analytical chemistry 15, 114 (1996). http://doi.org/10.1016/0165-9936(95)00098-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0165-9936(95)00098-4
|
|
|
“The use of synchrotron radiation for the characterization of artists' pigments and paintings”. Janssens K, Alfeld M, van der Snickt G, de Nolf W, Vanmeert F, Radepont M, Monico L, et al, Annual review of analytical chemistry 6, 399 (2013). http://doi.org/10.1146/ANNUREV-ANCHEM-062012-092702
Abstract: We review methods and recent studies in which macroscopic to (sub)microscopic X-ray beams were used for nondestructive analysis and characterization of pigments, paint microsamples, and/or entire paintings. We discuss the use of portable laboratory- and synchrotron-based instrumentation and describe several variants of X-ray fluorescence (XRF) analysis used for elemental analysis and imaging and combined with X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS). Macroscopic and microscopic (μ-)XRF variants of this method are suitable for visualizing the elemental distribution of key elements in paint multilayers. Technical innovations such as multielement, large-area XRF detectors have enabled such developments. The use of methods limited to elemental analysis or imaging usually is not sufficient to elucidate the chemical transformations that take place during natural pigment alteration processes. However, synchrotron-based combinations of μ-XRF, μ-XAS, and μ-XRD are suitable for such studies.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 7.435
Times cited: 46
DOI: 10.1146/ANNUREV-ANCHEM-062012-092702
|
|
|
“Colloquium Spectroscopicum Internationale 34, Antwerp, Belgium, 4-9 September 2005: preface”. Janssens K, Bogaerts A, van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 70, 907 (2006). http://doi.org/10.1016/j.talanta.2006.05.044
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.162
DOI: 10.1016/j.talanta.2006.05.044
|
|
|
“Recent trends in quantitative aspects of microscopic X-ray fluorescence analysis”. Janssens K, de Nolf W, van der Snickt G, Vincze L, Vekemans B, Terzano R, Brenker FE, Trends in analytical chemistry 29, 464 (2010). http://doi.org/10.1016/J.TRAC.2010.03.003
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 8.442
Times cited: 48
DOI: 10.1016/J.TRAC.2010.03.003
|
|
|
“A general-purpose interface between fortran and the low-level functions of the ibm-pc”. Janssens K, van Espen P, Trends in analytical chemistry 7, 128 (1988). http://doi.org/10.1016/0165-9936(88)87009-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0165-9936(88)87009-2
|
|
|
“Euroanalysis 14: the European Conference on Analytical Chemistry”. Janssens K, van Espen P, Van 't dack L, Analytical and bioanalytical chemistry 391, 1107 (2008). http://doi.org/10.1007/S00216-008-2114-9
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
Impact Factor: 3.431
DOI: 10.1007/S00216-008-2114-9
|
|
|
“The non-destructive determination of REE in fossilized bone using synchrotron radiation induced K-line X-ray microfluorescence analysis”. Janssens K, Vincze L, Vekemans B, Williams CT, Radtke M, Haller M, Knöchel A, Fresenius' journal of analytical chemistry 363, 413 (1999). http://doi.org/10.1007/S002160051212
Abstract: The sensitivity and applicability of the synchrotron radiation induced X-ray microfluorescence (mu-SRXRF) spectrometer at the Hamburg synchrotron laboratory Hasylab for the determination of the distribution of trace concentrations of rare-earth elements (REE) in fossilized bone are discussed and critically compared to those of other trace analytical methods such as instrumental neutron activation analysis (INAA) and LAMP-ICPMS (laser ablation microprobe inductively-coupled plasma mass spectrometry). Measurements were carried out on two bone samples from contrasting terrestrial depositional environments at Olduvai Gorge (Tanzania). Results indicate that the microdistribution of the REE in these biological materials is not homogeneous and that the relative abundance of these elements can provide information on the palaeoenvironment during the fossilization process. The heterogeneous distribution of the REE can be determined in a quantitative and completely non-destructive manner provided the concentrations of individual REE are above 10 mu g/g.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S002160051212
|
|
|
“Advantages of combined mu-XRF and mu-XRD for phase characterization of Ti-B-C ceramics compared with conventional X-ray diffraction”. Jaroszewicz J, de Nolf W, Janssens K, Michalski A, Falkenberg G, Analytical and bioanalytical chemistry 391, 1129 (2008). http://doi.org/10.1007/S00216-008-2097-6
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.431
Times cited: 7
DOI: 10.1007/S00216-008-2097-6
|
|
|
“Elemental trace analysis of small samples by proton-induced X-ray-emission”. Johansson TB, Van Grieken RE, Nelson JW, Winchester JW, Analytical chemistry 47, 855 (1975). http://doi.org/10.1021/AC60356A035
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC60356A035
|
|
|
“Micro-heterogeneity study of trace elements in BCR CRM 680 by means of synchrotron micro-XRF”. Kempenaers L, de Koster C, van Borm W, Janssens K, Fresenius' journal of analytical chemistry 369, 733 (2001). http://doi.org/10.1007/S002160000679
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 15
DOI: 10.1007/S002160000679
|
|
|
“A Monte Carlo model for studying the microheterogeneity of trace elements in reference materials by means of synchrotron microscopic X-ray fluorescence”. Kempenaers L, Janssens K, Vincze L, Vekemans B, Somogyi A, Drakopoulos M, Simionovici AS, Adams F, Analytical chemistry 74, 5017 (2002). http://doi.org/10.1021/AC025662G
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 21
DOI: 10.1021/AC025662G
|
|
|
“Photoelectrochemical behavior of phthalocyanine-sensitized TiO₂, in the presence of electron-shuttling mediators”. Khan SU, Trashin S, Beltran V, Korostei YS, Pelmus M, Gorun SM, Dubinina T V, Verbruggen SW, De Wael K, Analytical chemistry 94, 12723 (2022). http://doi.org/10.1021/ACS.ANALCHEM.2C02210
Abstract: Dye-sensitized TiO(2 )has found many applications for dye sensitized solar cells (DSSC), solar-to-chemical energy conversion, water/air purification systems, and (electro)chemical sensors. We report an electrochemical system for testing dye-sensitized materials that can be utilized in photoelectrochemical (PEC) sensors and energy conversion. Unlike related systems, the reported system does not require a direct electron transfer from semiconductors to electrodes. Rather, it relies on electron shuttling by redox mediators. A range of model photocatalytic materials were prepared using three different TiO2 materials (P25, P90, and PC500) and three sterically hindered phthalocyanines (Pcs) with electron-rich tert-butyl substituents (t-Bu4PcZn, t-Bu4PcAlCl, and t-Bu4PcH2). The materials were compared with previously developed TiO(2 )modified by electron-deficient, also sterically hindered fluorinated phthalocyanine F64PcZn, a singlet oxygen (O-1(2)) producer, as well as its metal-free derivative, F64PcH2. The PEC activity depended on the redox mediator, as well as the type of TiO2 and Pc. By comparing the responses of one-electron shuttles, such as K4Fe(CN)(4), and O-1(2)-reactive electron shuttles, such as phenol, it is possible to reveal the action mechanism of the supported photosensitizers, while the overall activity can be assessed using hydroquinone. t-Bu4PcAlCl showed significantly lower blank responses and higher specific responses toward chlorophenols compared to t-Bu4PcZn due to the electron-withdrawing effect of the Al3+ metal center. The combination of reactivity insights and the need for only microgram amounts of sensing materials renders the reported system advantageous for practical applications.
Keywords: A1 Journal article; Sustainable Energy, Air and Water Technology (DuEL); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 7.4
DOI: 10.1021/ACS.ANALCHEM.2C02210
|
|
|
“Optimization of the ion chromatographic quantification of airborne fluoride, acetate and formate in the Metropolitan Museum of Art, New York”. Kontozova-Deutsch V, Deutsch F, Bencs L, Krata A, Van Grieken R, De Wael K, Talanta : the international journal of pure and applied analytical chemistry 86, 372 (2011). http://doi.org/10.1016/J.TALANTA.2011.09.030
Abstract: Ion chromatographic (IC) methods have been compared in order to achieve an optimal separation of fluoride, acetate and formate under various elution conditions on two formerly introduced analytical columns (i and ii) and a novel one (iii): (i) an IonPac AS14 (250 mm × 4 mm I.D.), (ii) Allsep A-2 (150 mm × 4.6 mm I.D.), and (iii) an IC SI-50 4E (250 mm (length) × 4 mm (internal diameter – I.D.)). The IC conditions for the separation of the anions concerned were optimized on the IC SI-50 4E column. A near baseline separation of these anions was attained on the IonPac AS14, whereas the peaks of fluoride and acetate could not be resolved on the Allsep A-2. A baseline separation for the three anions was achieved on the IC SI-50 4E column, when applying an eluent mixture of 3.2 mmol/L Na2CO3 and 1.0 mmol/L NaHCO3 with a flow rate of 1.0 mL/min. The highest precision of 1.7, 3.0 and 2.8% and the best limits of detection (LODs) of 0.014, 0.22 and 0.17 mg/L for fluoride, acetate and formate, respectively, were obtained with the IC SI-50 4E column. Hence, this column was applied for the determination of the acetic and formic acid contents of air samples taken by means of passive gaseous sampling at the Metropolitan Museum of Art in New York, USA. Atmospheric concentrations of acetic and formic acid up to 1050 and 450 μg/m3, respectively, were found in non-aerated showcases of the museum. In galleries and outdoors, rather low levels of acetic and formic acid were detected with average concentrations of 50 and 10 μg/m3, respectively. The LOD data of acetate and formate on the IC SI-50 4E column correspond to around 0.5 μg/m3 for both acetic and formic acid in air samples.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.162
Times cited: 19
DOI: 10.1016/J.TALANTA.2011.09.030
|
|
|
“Efficient separation of acetate and formate by ion chromatography: application to air samples in a cultural heritage environment”. Kontozova-Deutsch V, Krata A, Deutsch F, Bencs L, Van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 75, 418 (2008). http://doi.org/10.1016/J.TALANTA.2007.11.025
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.TALANTA.2007.11.025
|
|
|
“Single-run ion chromatographic separation of inorganic and low-molecular-mass organic anions under isocratic elution: application to environmental samples”. Krata A, Kontozova-Deutsch V, Bencs L, Deutsch F, Van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 79, 16 (2009). http://doi.org/10.1016/J.TALANTA.2009.02.044
Abstract: For the isocratic ion chromatography (IC) separation of low-molecular-mass organic acids and inorganic anions three different anion-exchange columns were studied: IonPac AS14 (9 ìm particle size), Allsep A-2 (7 ìm particle size), and IC SI-50 4E (5 ìm particle size). A complete baseline separation for all analyzed anions (i.e., F−, acetate, formate, Cl−, NO2−, Br−, NO3−, HPO42− and SO42−) in one analytical cycle of shorter than 17 min was achieved on the IC SI-50 4E column, using an eluent mixture of 3.2 mM Na2CO3 and 1.0 mM NaHCO3 with a flow rate of 1.0 mL min−1. On the IonPac AS14 column, it was possible to separate acetate from inorganic anions in one run (i.e., less than 9 min), but not formate, under the following conditions: 3.5 mM Na2CO3 plus 1.0 mM NaHCO3 with a flow rate of 1.2 mL min−1. Therefore, it was necessary to adapt a second run with a 2.0 mM Na2B4O7 solution as an eluent under a flow rate of 0.8 mL min−1 for the separation of organic ions, which considerably enlarged the analysis time. For the Allsep A-2 column, using an eluent mixture of 1.2 mM Na2CO3 plus 1.5 mM NaHCO3 with a flow rate of 1.6 mL min−1, it was possible to separate almost all anions in one run within 25 min, except the fluoride-acetate critical pair. A Certified Multianion Standard Solution PRIMUS for IC was used for the validation of the analytical methods. The lowest RSDs (less than 1%) and the best LODs (0.02, 0.2, 0.16, 0.11, 0.06, 0.05, 0.04, 0.14 and 0.09 mg L−1 for F−, Ac−, For−, Cl−, NO2−, Br−, NO3−, HPO42− and SO42−, respectively) were achieved using the IC SI-50 4E column. This column was applied for the separation of concerned ions in environmental precipitation samples such as snow, hail and rainwater.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.TALANTA.2009.02.044
|
|
|
“Modeling of the sputtering process of cubic silver halide microcrystals and its relevance in depth profiling by secondary ion-mass spectrometry (SIMS)”. Lenaerts J, Verlinden G, Ignatova VA, van Vaeck L, Gijbels R, Geuens I, Fresenius' journal of analytical chemistry 370, 654 (2001). http://doi.org/10.1007/s002160100880
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 3
DOI: 10.1007/s002160100880
|
|
|
“Optimized transport setup for high repetition rate pulse-separated analysis in laser ablation-inductively coupled plasma mass spectrometry”. Lindner H, Autrique D, Garcia CC, Niemax K, Bogaerts A, Analytical chemistry 81, 4241 (2009). http://doi.org/10.1021/ac802627x
Abstract: An optimized laser ablation setup, proposed for high repetition rate inductively coupled plasma mass spectrometry (ICPMS) analyses such as 2D imaging or depth profiling, is presented. For such applications, the particle washout time needs to be as short as possible to allow high laser pulse frequencies for reduced analysis time. Therefore, it is desirable to have an ablation setup that operates as a laminar flow reactor (LFR). A top-down strategy was applied that resulted in the present design. In the first step, a previously applied ablation setup was analyzed on the basis of computational fluid dynamics (CFD) results presented by D. Autrique et al. (Spectrochim. Acta, B 2008, 63, 257−270). By means of CFD simulations, the design was modified in such a way that it operated in the LFR regime. Experimental results demonstrate that the current design can indeed be regarded as an LFR. Furthermore, the operation under LFR conditions allowed some insight into the initial radial concentration distribution if the experimental ICPMS signal and analytical expressions are taken into account. Recommendations for a modified setup for more resilient spatial distributions are given. With the present setup, a washout time of 140 ms has been achieved for a 3% signal area criterion. Therefore, 7 Hz repetition rates can be applied with the present setup. Using elementary formulas of the analytical model, an upper bound for the washout times for similar setups can be predicted. The authors believe that the presented setup geometry comes close to the achievable limit for reliable short washout times.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 18
DOI: 10.1021/ac802627x
|
|
|
“Simulation and experimental studies on plasma temperature, flow velocity, and injector diameter effects for an inductively coupled plasma”. Lindner H, Murtazin A, Groh S, Niemax K, Bogaerts A, Analytical chemistry 83, 9260 (2011). http://doi.org/10.1021/ac201699q
Abstract: An inductively coupled plasma (ICP) is analyzed by means of experiments and numerical simulation. Important plasma properties are analyzed, namely, the effective temperature inside the central channel and the mean flow velocity inside the plasma. Furthermore, the effect of torches with different injector diameters is studied by the model. The temperature inside the central channel is determined from the end-on collected line-to-background ratio in dependence of the injector gas flow rates. Within the limits of 3% deviation, the results of the simulation and the experiments are in good agreement in the range of flow rates relevant for the analysis of relatively large droplets, i.e., 50 μm. The deviation increases for higher gas flow rates but stays below 6% for all flow rates studied. The velocity of the gas inside the coil region was determined by side-on analyte emission measurements with single monodisperse droplet introduction and by the analysis of the injector gas path lines in the simulation. In the downstream region significantly higher velocities were found than in the upstream region in both the simulation and the experiment. The quantitative values show good agreement in the downstream region. In the upstream region, deviations were found in the absolute values which can be attributed to the flow conditions in that region and because the methods used for velocity determination are not fully consistent. Eddy structures are found in the simulated flow lines. These affect strongly the way taken by the path lines of the injector gas and they can explain the very long analytical signals found in the experiments at low flow rates. Simulations were performed for different injector diameters in order to find conditions where good analyte transport and optimum signals can be expected. The results clearly show the existence of a transition flow rate which marks the lower limit for effective analyte transport conditions through the plasma. A rule-of-thumb equation was extracted from the results from which the transition flow rate can be estimated for different injector diameters and different injector gas compositions.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 34
DOI: 10.1021/ac201699q
|
|