|
“Inelastic electron holography as a variant of the Feynman thought experiment”. Potapov PL, Verbeeck J, Schattschneider P, Lichte H, van Dyck D, Ultramicroscopy 107, 559 (2007). http://doi.org/10.1016/j.ultramic.2006.11.003
Abstract: Using a combination of electron holography and energy filtering, interference fringes produced after inelastic interaction of electrons with hydrogen molecules are examined. Surprisingly, the coherence of inelastic scattering increases when moving from the surface of a hydrogen-containing bubble to the vacuum. This phenomenon can be understood in terms of the Feynman two-slit thought experiment with a variable ambiguity of the which-way registration. (C) 2006 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 13
DOI: 10.1016/j.ultramic.2006.11.003
|
|
|
“Acquisition of the EELS data cube by tomographic reconstruction”. van den Broek W, Verbeeck J, de Backer S, Scheunders P, Schryvers D, Ultramicroscopy 106, 269 (2006). http://doi.org/10.1016/j.ultramic.2005.09.001
Abstract: Energy filtered TEM, EFTEM, provides three-dimensional data, two spatial and one spectral dimension. We propose to acquire these data by measuring a series of images with a defocused energy filter. It will be shown that each image is a projection of the data on the detector and that reconstruction of the data out of a sufficient number of such projections using a tomographic reconstruction algorithm is possible. This technique uses only a fraction of the electron dose an energy filtered series (EFS) needs for the same spectral and spatial resolution and the same mean signal-to-noise ratio. (c) 2005 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 6
DOI: 10.1016/j.ultramic.2005.09.001
|
|
|
“Determination of the mean inner potential in III-V semiconductors, Si and Ge by density functional theory and electron holography”. Kruse P, Schowalter M, Lamoen D, Rosenauer A, Gerthsen D, Ultramicroscopy 106, 105 (2006). http://doi.org/10.1016/j.ultramic.2005.06.057
Keywords: A1 Journal article; Electron Microscopy for Materials Science (EMAT);
Impact Factor: 2.843
Times cited: 50
DOI: 10.1016/j.ultramic.2005.06.057
|
|
|
“An efficient way of including thermal diffuse scattering in simulation of scanning transmission electron microscopic images”. Croitoru MD, van Dyck D, Van Aert S, Bals S, Verbeeck J, Ultramicroscopy 106, 933 (2006). http://doi.org/10.1016/j.ultramic.2006.04.006
Abstract: We propose an improved image simulation procedure for atomic-resolution annular dark-field scanning transmission electron microscopy (STEM) based on the multislice formulation, which takes thermal diffuse scattering fully into account. The improvement with regard to the classical frozen phonon approach is realized by separating the lattice configuration statistics from the dynamical scattering so as to avoid repetitive calculations. As an example, the influence of phonon scattering on the image contrast is calculated and investigated. STEM image simulation of crystals can be applied with reasonable computing times to problems involving a large number of atoms and thick or large supercells.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Condensed Matter Theory (CMT); Vision lab
Impact Factor: 2.843
Times cited: 18
DOI: 10.1016/j.ultramic.2006.04.006
|
|
|
“Electron inelastic, scattering and anisotropy: the two-dimensional point of view”. Radtke G, Botton GA, Verbeeck J, Ultramicroscopy 106, 1082 (2006). http://doi.org/10.1016/j.ultramic.2006.04.023
Abstract: The measurement of the electronic structure of anisotropic materials using energy loss near edge structure (ELNES) spectroscopy is an important field of microanalysis in transmission electron microscopy. We present a novel method to study the angular dependence of electron inelastic scattering in anisotropic materials. This method has been applied to the study of 1s -> pi* and sigma* transitions on the carbon K edge in pyrolitic graphite. An excellent agreement between experimental and theoretical two-dimensional scattering patterns has been found. In particular, the need of a fully relativistic calculation of the inelastic scattering cross-section to explain the experimental results is demonstrated. (c) 2006 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 5
DOI: 10.1016/j.ultramic.2006.04.023
|
|
|
“Experiments on inelastic electron holography”. Potapov P, Lichte H, Verbeeck J, van Dyck D, Ultramicroscopy 106, 1012 (2006). http://doi.org/10.1016/j.ultramic.2006.05.012
Abstract: Using the combination of an electron biprism and an energy filter, the coherence distribution in an inelastically scattered wave-field is measured. It is found that the degree of coherence decreases rapidly with increasing distance between two superimposed points in the object, and with increasing energy-loss. In a Si sample, coherence of plasmon scattering increases in vacuum with the distance from the edge of the sample. (c) 2006 Published by Elsevier B.V.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 28
DOI: 10.1016/j.ultramic.2006.05.012
|
|
|
“Interpretation of “Energy-filtered electron-diffracted beam holography&rdquo, by R.A. Herring”. Verbeeck J, Ultramicroscopy 106, 461 (2006). http://doi.org/10.1016/j.ultramic.2005.12.004
Abstract: A straightforward application of the theoretical framework presented by Verbeeck et al. [Ultramicroscopy 102 (2005) 239] is presented to explain the energy-filtered electron-diffracted beam holography experiments published by Herring [Ultramicroscopy 104 (2005) 261]. It is shown that the theory is in agreement with all experimental findings, which leads to the interpretation that the experiments are mainly measuring the angular coherence of the source image rather than exposing details on the coherence properties of inelastic scattering. A change in experimental parameters is proposed, which could result in interesting information about the coherence in all inelastic scattering process. (c) 2006 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 8
DOI: 10.1016/j.ultramic.2005.12.004
|
|
|
“Model-based quantification of EELS spectra: including the fine structure”. Verbeeck J, Van Aert S, Bertoni G, Ultramicroscopy 106, 976 (2006). http://doi.org/10.1016/j.ultramic.2006.05.006
Abstract: An extension to model-based electron energy loss spectroscopy (EELS) quantification is reported to improve the possibility of modelling fine structure changes in electron energy loss spectra. An equalisation function is used in the energy loss near edge structure (ELNES) region to model the differences between a single atom differential cross section and the cross section for an atom in a crystal. The equalisation function can be shown to approximate the relative density of unoccupied states for the given excitation edge. On a set of 200 experimental h-BN spectra, this technique leads to statistically acceptable models resulting into unbiased estimates of relative concentrations and making the estimated precisions come very close to the Cramer-Rao lower bound (CRLB). The method greatly expands the useability of model-based EELS quantification to spectra with pronounced fine structure. Another benefit of this model is that one also gets an estimate of the unoccupied density of states for a given excitation edge, without having to do background removal and deconvolution, making the outcome intrinsically more reliable and less noisy. (c) 2006 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 38
DOI: 10.1016/j.ultramic.2006.05.006
|
|
|
“Quantification of crystalline and amorphous content in porous TiO2 samples from electron energy loss spectroscopy”. Bertoni G, Beyers E, Verbeeck J, Mertens M, Cool P, Vansant EF, Van Tendeloo G, Ultramicroscopy 106, 630 (2006). http://doi.org/10.1016/j.ultramic.2006.03.006
Abstract: We present an efficient method for the quantification of crystalline versus amorphous phase content in mesoporous materials, making use of electron energy loss spectroscopy. The method is based on fitting a superposition of core-loss edges using the maximum likelihood method with measured reference spectra. We apply the method to mesoporous TiO2 samples. We show that the absolute amount of the crystalline phase can be determined with an accuracy below 5%. This method takes also the amorphous phase into account, where standard X-ray diffraction is only quantitative for crystalline phases and not for amorphous phase. (c) 2006 Elsevier B.V.. All rights reserved.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Laboratory of adsorption and catalysis (LADCA)
Impact Factor: 2.843
Times cited: 83
DOI: 10.1016/j.ultramic.2006.03.006
|
|
|
“Maximum likelihood estimation of structure parameters from high resolution electron microscopy images: part 1: a theoretical framework”. den Dekker AJ, Van Aert S, van den Bos A, van Dyck D, Ultramicroscopy 104, 83 (2005). http://doi.org/10.1016/j.ultramic.2005.03.001
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 70
DOI: 10.1016/j.ultramic.2005.03.001
|
|
|
“Maximum likelihood estimation of structure parameters from high resolution electron microscopy images : part 2 : a practical example”. Van Aert S, den Dekker AJ, van den Bos A, van Dyck D, Chen JH, Ultramicroscopy 104, 107 (2005). http://doi.org/10.1016/j.ultramic.2005.03.002
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 37
DOI: 10.1016/j.ultramic.2005.03.002
|
|
|
“Nonlinear imaging using annular dark field TEM”. Bals S, Kilaas R, Kisielowski C, Ultramicroscopy 104, 281 (2005). http://doi.org/10.1016/j.ultramic.2005.05.004
Abstract: Annular dark field TEM images exhibit a dominant mass-thickness contrast that can be quantified to extract single atom scattering cross sections. On top of this incoherent background, additional lattice fringes appear with a nonlinear information limit of 1.2 angstrom at 150 kV. The formation of these fringes is described by coherent nonlinear imaging theory and good agreement is found between experimental and simulated images. Calculations furthermore predict that the use of aberration corrected microscopes will improve the image quality dramatically. (c) 2005 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 15
DOI: 10.1016/j.ultramic.2005.05.004
|
|
|
“Plasmon holographic experiments: theoretical framework”. Verbeeck J, van Dyck D, Lichte H, Potapov P, Schattschneider P, Ultramicroscopy 102, 239 (2005). http://doi.org/10.1016/j.ultramic.2004.10.005
Abstract: A theoretical framework is described to understand the results of plasmon holography experiments leading to insight in the meaning of the experimental results and pointing out directions for future experiments. The framework is based on the formalism of mutual intensity to describe how coherence is transferred through an optical system. For the inelastic interaction with the object, an expression for the volume. plasmon excitations in a free electron gas is used as a model for the behaviour of aluminium. The formalism leads to a clear graphical intuitive tool for under-standing the experiments. It becomes evident that the measured coherence is solely related to the angular distribution of the plasmon scattering in the case of bulk plasmons. After describing the framework, the special case of coherence outside a spherical particle is treated and the seemingly controversial idea of a plasmon with a limited coherence length obtained front experiments is clarified. (C) 2004 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 43
DOI: 10.1016/j.ultramic.2004.10.005
|
|
|
“Measuring the absolute position of EELS ionisation edges in a TEM”. Potapov PL, Schryvers D, Ultramicroscopy 99, 73 (2004). http://doi.org/10.1016/S0304-3991(03)00185-2
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 29
DOI: 10.1016/S0304-3991(03)00185-2
|
|
|
“Model based quantification of EELS spectra”. Verbeeck J, Van Aert S, Ultramicroscopy 101, 207 (2004). http://doi.org/10.1016/j.ultramic.2004.06.004
Abstract: Recent advances in model based quantification of electron energy loss spectra (EELS) are reported. The maximum likelihood method for the estimation of physical parameters describing an EELS spectrum, the validation of the model used in this estimation procedure, and the computation of the attainable precision, that is, the theoretical lower bound on the variance of these estimates, are discussed. Experimental examples on An and GaAs samples show the power of the maximum likelihood method and show that the theoretical prediction of the attainable precision can be closely approached even for spectra with overlapping edges where conventional EELS quantification fails. To provide end-users with a low threshold alternative to conventional quantification, a user friendly program was developed which is freely available under a GNU public license. (C) 2004 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 147
DOI: 10.1016/j.ultramic.2004.06.004
|
|
|
“Is atomic resolution transmission electron microscopy able to resolve and refine amorphous structures?”.van Dyck D, Van Aert S, den Dekker AJ, van den Bos A, Ultramicroscopy 98, 27 (2003). http://doi.org/10.1016/S0304-3991(03)00023-8
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 26
DOI: 10.1016/S0304-3991(03)00023-8
|
|
|
“Optimal experimental design of STEM measurement of atom column positions”. Van Aert S, den Dekker AJ, van Dyck D, van den Bos A, Ultramicroscopy 90, 273 (2002). http://doi.org/10.1016/S0304-3991(01)00152-8
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 35
DOI: 10.1016/S0304-3991(01)00152-8
|
|
|
“Does a monochromator improve the precision in quantitative HRTEM?”.den Dekker AJ, Van Aert S, van Dyck D, van den Bos A, Geuens P, Ultramicroscopy 89, 275 (2001). http://doi.org/10.1016/S0304-3991(01)00089-4
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 22
DOI: 10.1016/S0304-3991(01)00089-4
|
|
|
“Computational comparisons between the conventional multislice method and the third-order multislice method for calculating high-energy electron diffraction and imaging”. Chen JH, van Dyck D, op de Beeck M, van Landuyt J, Ultramicroscopy 69, 219 (1997)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 11
|
|
|
“An alternative approach for ζ-factor measurement using pure element nanoparticles”. Zanaga D, Altantzis T, Sanctorum J, Freitag B, Bals S, Ultramicroscopy 164, 11 (2016). http://doi.org/10.1016/j.ultramic.2016.03.002
Abstract: It is very challenging to measure the chemical composition of hetero nanostructures in a reliable and quantitative manner. Here, we propose a novel and straightforward approach that can be used to quantify energy dispersive X-ray spectra acquired in a transmission electron microscope. Our method is based on a combination of electron tomography and the so-called ζ-factor technique. We will demonstrate the reliability of our approach as well as its applicability by investigating Au-Ag and Au-Pt hetero nanostructures. Given its simplicity, we expect that the method could become a new standard in the field of chemical characterization using electron microscopy.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 19
DOI: 10.1016/j.ultramic.2016.03.002
|
|
|
“Progress and new advances in simulating electron microscopy datasets using MULTEM”. Lobato I, Van Aert S, Verbeeck J, Ultramicroscopy 168, 17 (2016). http://doi.org/10.1016/j.ultramic.2016.06.003
Abstract: A new version of the open source program MULTEM is presented here. It includes a graphical user interface, tapering truncation of the atomic potential, CPU multithreading functionality, single/double precision calculations, scanning transmission electron microscopy (STEM) simulations using experimental detector sensitivities, imaging STEM (ISTEM) simulations, energy filtered transmission electron microscopy (EFTEM) simulations, STEM electron energy loss spectroscopy (EELS) simulations along with other improvements in the algorithms. We also present a mixed channeling approach for the calculation of inelastic excitations, which allows one to considerably speed up time consuming EFTEM/STEM-EELS calculations.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 43
DOI: 10.1016/j.ultramic.2016.06.003
|
|
|
“Efficient creation of electron vortex beams for high resolution STEM imaging”. Béché, A, Juchtmans R, Verbeeck J, Ultramicroscopy 178, 12 (2017). http://doi.org/10.1016/j.ultramic.2016.05.006
Abstract: The recent discovery of electron vortex beams carrying quantised angular momentum in the TEM has led to an active field of research, exploring a variety of potential applications including the possibility of mapping magnetic states at the atomic scale. A prerequisite for this is the availability of atomic sized electron vortex beams at high beam current and mode purity. In this paper we present recent progress showing that by making use of the Aharonov-Bohm effect near the tip of a long single domain ferromagnetic Nickel needle, a very efficient aperture for the production of electron vortex beams can be realised. The aperture transmits more than 99% of all electrons and provides a vortex mode purity of up to 92%. Placing this aperture in the condenser plane of a state of the art Cs corrected microscope allows us to demonstrate atomic resolution HAADF STEM images with spatial resolution better than 1 Angstrom, in agreement with theoretical expectations and only slightly inferior to the performance of a non-vortex probe on the same instrument.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 30
DOI: 10.1016/j.ultramic.2016.05.006
|
|
|
“Measurement of atomic electric fields and charge densities from average momentum transfers using scanning transmission electron microscopy”. Muller-Caspary K, Krause FF, Grieb T, Loffler S, Schowalter M, Béché, A, Galioit V, Marquardt D, Zweck J, Schattschneider P, Verbeeck J, Rosenauer A, Ultramicroscopy 178, 62 (2016). http://doi.org/10.1016/j.ultramic.2016.05.004
Abstract: This study sheds light on the prerequisites, possibilities, limitations and interpretation of high-resolution differential phase contrast (DPC) imaging in scanning transmission electron microscopy (STEM). We draw particular attention to the well-established DPC technique based on segmented annular detectors and its relation to recent developments based on pixelated detectors. These employ the expectation value of the momentum transfer as a reliable measure of the angular deflection of the STEM beam induced by an electric field in the specimen. The influence of scattering and propagation of electrons within the specimen is initially discussed separately and then treated in terms of a two-state channeling theory. A detailed simulation study of GaN is presented as a function of specimen thickness and bonding. It is found that bonding effects are rather detectable implicitly, e.g., by characteristics of the momentum flux in areas between the atoms than by directly mapping electric fields and charge densities. For strontium titanate, experimental charge densities are compared with simulations and discussed with respect to experimental artifacts such as scan noise. Finally, we consider practical issues such as figures of merit for spatial and momentum resolution, minimum electron dose, and the mapping of larger-scale, built-in electric fields by virtue of data averaged over a crystal unit cell. We find that the latter is possible for crystals with an inversion center. Concerning the optimal detector design, this study indicates that a sampling of 5mrad per pixel is sufficient in typical applications, corresponding to approximately 10x10 available pixels.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 93
DOI: 10.1016/j.ultramic.2016.05.004
|
|
|
“Three dimensional mapping of Fe dopants in ceria nanocrystals using direct spectroscopic electron tomography”. Goris B, Meledina M, Turner S, Zhong Z, Batenburg KJ, Bals S, Ultramicroscopy 171, 55 (2016). http://doi.org/10.1016/j.ultramic.2016.08.017
Abstract: Electron tomography is a powerful technique for the 3D characterization of the morphology of nanostructures. Nevertheless, resolving the chemical composition of complex nanostructures in 3D remains challenging and the number of studies in which electron energy loss spectroscopy (EELS) is combined with tomography is limited. During the last decade, dedicated reconstruction algorithms have been developed for HAADF-STEM tomography using prior knowledge about the investigated sample. Here, we will use the prior knowledge that the experimental spectrum of each reconstructed voxel is a linear combination of a well-known set of references spectra in a so-called direct spectroscopic tomography technique. Based on a simulation experiment, it is shown that this technique provides superior results in comparison to conventional reconstruction methods for spectroscopic data, especially for spectrum images containing a relatively low signal to noise ratio. Next, this technique is used to investigate the spatial distribution of Fe dopants in Fe:Ceria nanoparticles in 3D. It is shown that the presence of the Fe2+ dopants is correlated with a reduction of the Ce atoms from Ce4+ towards Ce3+. In addition, it is demonstrated that most of the Fe dopants are located near the voids inside the nanoparticle.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 13
DOI: 10.1016/j.ultramic.2016.08.017
|
|
|
“Measuring the height-to-height correlation function of corrugation in suspended graphene”. Kirilenko DA, Brunkov PN, Ultramicroscopy 165, 1 (2016). http://doi.org/10.1016/j.ultramic.2016.03.010
Abstract: Nanocorrugation of 2D crystals is an important phenomenon since it affects their electronic and mechanical properties. The corrugation may have various sources; one of them is flexural phonons that, in particular, are responsible for the thermal conductivity of graphene. A study of corrugation of just the suspended graphene can reveal much of valuable information on the physics of this complicated phenomenon. At the same time, the suspended crystal nanorelief can hardly be measured directly because of high flexibility of the 2D crystal. Moreover, the relief portion related to rapid out-of-plane oscillations (flexural phonons) is also inaccessible by such measurements. Here we present a technique for measuring the Fourier components of the height-height correlation function H(q) of suspended graphene which includes the effect of flexural phonons. The technique is based on the analysis of electron diffraction patterns. The H(q) is measured in the range of wavevectors q approximately 0.4-4.5nm(-1). At the upper limit of this range H(q) does follow the T/kappaq(4) law. So, we measured the value of suspended graphene bending rigidity kappa=1.2+/-0.4eV at ambient temperature T approximately 300K. At intermediate wave vectors, H(q) follows a slightly weaker exponent than theoretically predicted q(-3.15) but is closer to the results of the molecular dynamics simulation. At low wave vectors, the dependence becomes even weaker, which may be a sign of influence of charge carriers on the dynamics of undulations longer than 10nm. The technique presented can be used for studying physics of flexural phonons in other 2D materials.
Keywords: A1 Journal article; Electron Microscopy for Materials Science (EMAT);
Impact Factor: 2.843
Times cited: 3
DOI: 10.1016/j.ultramic.2016.03.010
|
|
|
“Detecting and locating light atoms from high-resolution STEM images: The quest for a single optimal design”. Gonnissen J, De Backer A, den Dekker AJ, Sijbers J, Van Aert S, Ultramicroscopy 170, 128 (2016). http://doi.org/10.1016/j.ultramic.2016.07.014
Abstract: In the present paper, the optimal detector design is investigated for both detecting and locating light atoms from high resolution scanning transmission electron microscopy (HR STEM) images. The principles of detection theory are used to quantify the probability of error for the detection of light atoms from HR STEM images. To determine the optimal experiment design for locating light atoms, use is made of the so-called Cramer-Rao Lower Bound (CRLB). It is investigated if a single optimal design can be found for both the detection and location problem of light atoms. Furthermore, the incoming electron dose is optimised for both research goals and it is shown that picometre range precision is feasible for the estimation of the atom positions when using an appropriate incoming electron dose under the optimal detector settings to detect light atoms.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 6
DOI: 10.1016/j.ultramic.2016.07.014
|
|
|
“StatSTEM: An efficient approach for accurate and precise model-based quantification of atomic resolution electron microscopy images”. De Backer A, van den Bos KHW, Van den Broek W, Sijbers J, Van Aert S, Ultramicroscopy 171, 104 (2016). http://doi.org/10.1016/j.ultramic.2016.08.018
Abstract: An efficient model-based estimation algorithm is introduced to quantify the atomic column positions and intensities from atomic resolution (scanning) transmission electron microscopy ((S)TEM) images. This algorithm uses the least squares estimator on image segments containing individual columns fully accounting for overlap between neighbouring columns, enabling the analysis of a large field of view. For this algorithm, the accuracy and precision with which measurements for the atomic column positions and scattering cross-sections from annular dark field (ADF) STEM images can be estimated, has been investigated. The highest attainable precision is reached even for low dose images. Furthermore, the advantages of the model-based approach taking into account overlap between neighbouring columns are highlighted. This is done for the estimation of the distance between two neighbouring columns as a function of their distance and for the estimation of the scattering cross-section which is compared to the integrated intensity from a Voronoi cell. To provide end-users this well-established quantification method, a user friendly program, StatSTEM, is developed which is freely available under a GNU public license.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 43
DOI: 10.1016/j.ultramic.2016.08.018
|
|
|
“Deactivation study of Fe2O3-CeO2 during redox cycles for CO production from CO2”. Dharanipragada NVRA, Meledina M, Galvita VV, Poelman H, Turner S, Van Tendeloo G, Detavernier C, Marin GB, Industrial and engineering chemistry research 55, 5911 (2016). http://doi.org/10.1021/acs.iecr.6b00963
Abstract: Deactivation was investigated in Fe2O3-CeO2 oxygen storage materials during repeated H-2-reduction and CO2-reoxidation. In situ XRD, XAS, and TEM were used to identify phases, crystallite sizes, and morphological changes upon cycling operation. The effect of redox cycling was investigated both in Fe-rich (80 wt % Fe2O3-CeO2) and Ce-rich (10 wt %Fe2O3-CeO2) materials. The former consisted of 100 nm Fe2O3 particles decorated with 5-10 nm Ce1-xFexO2-x. The latter presented CeO2 with incorporated Fe, i.e. a solid solution of Ce1-xFexO2-x, as the main oxygen carrier. By modeling the EXAFS Ce-K signal for as-prepared 10 wt %Fe2O3-CeO2, the amount of Fe in CeO2 was determined as 21 mol %, corresponding to 86% of the total iron content. Sintering and solid solid transformations, the latter including both new phase formation and element segregation, were identified as deactivation pathways upon redox cycling. In Ce-rich material, perovskite (CeFeO3) was identified by XRD. This phase remained inert during reduction and reoxidation, resulting in an overall lower oxygen storage capacity. Further, Fe segregated from the solid solution, thereby decreasing its reducibility. In addition, an increase in crystallite size occurred for all phases. In Fe-rich material, sintering is the main deactivation pathway, although Fe segregation from the solid solution and perovskite formation cannot be excluded.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 26
DOI: 10.1021/acs.iecr.6b00963
|
|
|
“Thickness dependence of scattering cross-sections in quantitative scanning transmission electron microscopy”. Martinez GT, van den Bos KHW, Alania M, Nellist PD, Van Aert S, Ultramicroscopy 187, 84 (2018). http://doi.org/10.1016/j.ultramic.2018.01.005
Abstract: In quantitative scanning transmission electron microscopy (STEM), scattering cross-sections have been shown to be very sensitive to the number of atoms in a column and its composition. They correspond to the integrated intensity over the atomic column and they outperform other measures. As compared to atomic column peak intensities, which saturate at a given thickness, scattering cross-sections increase monotonically. A study of the electron wave propagation is presented to explain the sensitivity of the scattering cross-sections. Based on the multislice algorithm, we analyse the wave propagation inside the crystal and its link to the scattered signal for the different probe positions contained in the scattering cross-section for detector collection in the low-, middle- and high-angle regimes. The influence to the signal from scattering of neighbouring columns is also discussed.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 4
DOI: 10.1016/j.ultramic.2018.01.005
|
|
|
“Locating light and heavy atomic column positions with picometer precision using ISTEM”. van den Bos KHW, Krause FF, Béché, A, Verbeeck J, Rosenauer A, Van Aert S, Ultramicroscopy 172, 75 (2016). http://doi.org/10.1016/j.ultramic.2016.10.003
Abstract: Recently, imaging scanning transmission electron microscopy (ISTEM) has been proposed as a promising new technique combining the advantages of conventional TEM (CTEM) and STEM [1]. The ability to visualize light and heavy elements together makes it a particularly interesting new, spatially incoherent imaging mode. Here, we evaluate this technique in term of precision with which atomic column locations can be measured. By using statistical parameter estimation theory, we will show that these locations can be accurately measured with a precision in the picometer range. Furthermore, a quantitative comparison is made with HAADF STEM imaging to investigate the advantages of ISTEM.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 8
DOI: 10.1016/j.ultramic.2016.10.003
|
|