“Quantitative annular dark field scanning transmission electron microscopy for nanoparticle atom-counting: What are the limits?”.De Backer A, De Wael A, Gonnissen J, Martinez GT, Béché, A, MacArthur KE, Jones L, Nellist PD, Van Aert S, Journal of physics : conference series 644Electron Microscopy and Analysis Group Conference (EMAG), JUN 02-JUL 02, 2015, Manchester, ENGLAND, 012034 (2015). http://doi.org/10.1088/1742-6596/644/1/012034
Abstract: Quantitative atomic resolution annular dark field scanning transmission electron microscopy (ADF STEM) has become a powerful technique for nanoparticle atom-counting. However, a lot of nanoparticles provide a severe characterisation challenge because of their limited size and beam sensitivity. Therefore, quantitative ADF STEM may greatly benefit from statistical detection theory in order to optimise the instrumental microscope settings such that the incoming electron dose can be kept as low as possible whilst still retaining single-atom precision. The principles of detection theory are used to quantify the probability of error for atom-counting. This enables us to decide between different image performance measures and to optimise the experimental detector settings for atom-counting in ADF STEM in an objective manner. To demonstrate this, ADF STEM imaging of an industrial catalyst has been conducted using the near-optimal detector settings. For this experiment, we discussed the limits for atom-counting diagnosed by combining a thorough statistical method and detailed image simulations.
Keywords: P1 Proceeding; Electron microscopy for materials research (EMAT)
DOI: 10.1088/1742-6596/644/1/012034
|
|
|
“Plasma treatment causes structural modifications in lysozyme, and increases cytotoxicity towards cancer cells”. Attri P, Kaushik NK, Kaushik N, Hammerschmid D, Privat-Maldonado A, De Backer J, Shiratani M, Choi EH, Bogaerts A, International Journal Of Biological Macromolecules 182, 1724 (2021). http://doi.org/10.1016/j.ijbiomac.2021.05.146
Abstract: Bacterial and mammalian proteins, such as lysozyme, are gaining increasing interest as anticancer drugs. This study aims to modify the lysozyme structure using cold atmospheric plasma to boost its cancer cell killing effect. We investigated the structure at acidic and neutral pH using various experimental techniques (circular dichroism, fluorescence, and mass spectrometry) and molecular dynamics simulations. The controlled structural modification of lysozyme at neutral pH enhances its activity, while the activity was lost at acidic pH at the same treatment conditions. Indeed, a larger number of amino acids were oxidized at acidic pH after plasma treatment, which results in a greater distortion of the lysozyme structure, whereas only limited structural changes were observed in lysozyme after plasma treatment at neutral pH. We found that the plasma-treated lysozyme significantly induced apoptosis to the cancer cells. Our results reveal that plasma-treated lysozyme could have potential as a new cancer cell killing drug.
Keywords: A1 Journal Article; Lysozyme; Cold atmospheric plasma; Cancer cell death; Plasma, laser ablation and surface modeling Antwerp (PLASMANT) ;
Impact Factor: 3.671
DOI: 10.1016/j.ijbiomac.2021.05.146
|
|
|
“Obtaining 3D Atomic Reconstructions from Electron Microscopy Images Using a Bayesian Genetic Algorithm: Possibilities, Insights, and Limitations”. Stoops T, De Backer A, Lobato I, Van Aert S, Microscopy and Microanalysis (2024). http://doi.org/10.1093/mam/ozae090
Abstract: The Bayesian genetic algorithm (BGA) is a powerful tool to reconstruct the 3D structure of mono-atomic single-crystalline metallic nanoparticles imaged using annular dark field scanning transmission electron microscopy. The number of atoms in a projected atomic column in the image is used as input to obtain an accurate and atomically precise reconstruction of the nanoparticle, taking prior knowledge and the finite precision of atom counting into account. However, as the number of parameters required to describe a nanoparticle with atomic detail rises quickly with the size of the studied particle, the computational costs of the BGA rise to prohibitively expensive levels. In this study, we investigate these computational costs and propose methods and control parameters for efficient application of the algorithm to nanoparticles of at least up to 10 nm in size.
Keywords: A1 Journal Article; Electron Microscopy for Materials Science (EMAT) ;
Impact Factor: 2.8
DOI: 10.1093/mam/ozae090
|
|
|
“Investigation of the Octahedral Network Structure in Formamidinium Lead Bromide Nanocrystals by Low-Dose Scanning Transmission Electron Microscopy”. Schrenker NJ, Braeckevelt T, De Backer A, Livakas N, Yu C-P, Friedrich T, Roeffaers MBJ, Hofkens J, Verbeeck J, Manna L, Van Speybroeck V, Van Aert S, Bals S, Nano Letters 24, 10936 (2024). http://doi.org/10.1021/acs.nanolett.4c02811
Abstract: Metal halide perovskites (MHP) are highly promising semiconductors. In this study, we focus on FAPbBr3 nanocrystals, which are of great interest for green light-emitting diodes. Structural parameters significantly impact the properties of MHPs and are linked to phase instability, which hampers long-term applications. Clearly, there is a need for local and precise characterization techniques at the atomic scale, such as transmission electron microscopy. Because of the high electron beam sensitivity of MHPs, these investigations are extremely challenging. Here, we applied a low-dose method based on four-dimensional scanning transmission electron microscopy. We quantified the observed elongation of the projections of the Br atomic columns, suggesting an alternation in the position of the Br atoms perpendicular to the Pb–Br–Pb bonds. Together with molecular dynamics simulations, these results remarkably reveal local distortions in an on-average cubic structure. Additionally, this study provides an approach to prospectively investigating the fundamental degradation mechanisms of MHPs.
Keywords: A1 Journal Article; Electron Microscopy for Materials Science (EMAT) ;
Impact Factor: 10.8
DOI: 10.1021/acs.nanolett.4c02811
|
|
|
“Characterization of regulated cancer cell death pathways induced by the different modalities of non-thermal plasma treatment”. Biscop E, Baroen J, De Backer J, Vanden Berghe W, Smits E, Bogaerts A, Lin A, Cell Death Discovery 10, 416 (2024). http://doi.org/10.1038/s41420-024-02178-x
Abstract: Non-thermal plasma (NTP) has shown promising anti-cancer effects, but there is still limited knowledge about the underlying cell death mechanisms induced by NTP and inherent differences between NTP treatment modalities. This study aimed to investigate four major regulated cell death (RCD) pathways, namely apoptosis, pyroptosis, necroptosis, and ferroptosis, in melanoma cancer cells following NTP treatment, and to provide an overview of molecular mechanistic differences between direct and indirect NTP treatment modalities. To discriminate which cell death pathways were triggered after treatment, specific inhibitors of apoptosis, pyroptosis, necroptosis, and ferroptosis were evaluated. RCD-specific molecular pathways were further investigated to validate the findings with inhibitors. Both direct and indirect NTP treatment increased caspase 3/7 and annexin V expression, indicative of apoptosis, as well as lipid peroxidation, characteristic of ferroptosis. Pyroptosis, on the other hand, was only induced by direct NTP treatment, evidenced by increased caspase 1 activity, whereas necroptosis was stimulated in a cell line-dependent manner. These findings highlight the molecular differences and implications of direct and indirect NTP treatment for cancer therapy. Altogether, activation of multiple cell death pathways offers advantages in minimizing treatment resistance and enhancing therapeutic efficacy, particularly in a combination setting. Understanding the mechanisms underlying NTP-induced RCD will enable the development of strategic combination therapies targeting multiple pathways to achieve cancer lethality.
Keywords: A1 Journal Article; Plasma, laser ablation and surface modeling Antwerp (PLASMANT) ;
DOI: 10.1038/s41420-024-02178-x
|
|
|
“Acquisition of the EELS data cube by tomographic reconstruction”. van den Broek W, Verbeeck J, de Backer S, Scheunders P, Schryvers D, Ultramicroscopy 106, 269 (2006). http://doi.org/10.1016/j.ultramic.2005.09.001
Abstract: Energy filtered TEM, EFTEM, provides three-dimensional data, two spatial and one spectral dimension. We propose to acquire these data by measuring a series of images with a defocused energy filter. It will be shown that each image is a projection of the data on the detector and that reconstruction of the data out of a sufficient number of such projections using a tomographic reconstruction algorithm is possible. This technique uses only a fraction of the electron dose an energy filtered series (EFS) needs for the same spectral and spatial resolution and the same mean signal-to-noise ratio. (c) 2005 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 6
DOI: 10.1016/j.ultramic.2005.09.001
|
|
|
Verhulst SL, de Backer J, Van Gaal L, de Backer W, Desager K (2008) Adenotonsillectomy as first-line treatment for sleep-disordered breathing in obese children. New York, 1399
Keywords: L1 Letter to the editor; Condensed Matter Theory (CMT); Laboratory Experimental Medicine and Pediatrics (LEMP)
Impact Factor: 13.204
|
|
|
“Anatomical and functional changes in the upper airways of sleep apnea patients due to mandibular repositioning: a large scale study”. van Holsbeke C, de Backer J, Vos W, Verdonck P, van Ransbeeck P, Claessens T, Braem M, Vanderveken O, de Backer W, Journal of biomechanics 44, 442 (2011). http://doi.org/10.1016/j.jbiomech.2010.09.026
Abstract: The obstructive sleep apnea-hypopnea syndrome (OSAHS) is a sleep related breathing disorder. A popular treatment is the use of a mandibular repositioning appliance (MRA) which advances the mandibula during the sleep and decreases the collapsibility of the upper airway. The success rate of such a device is, however, limited and very variable within a population of patients. Previous studies using computational fluid dynamics have shown that there is a decrease in upper airway resistance in patients who improve clinically due to an MRA. In this article, correlations between patient-specific anatomical and functional parameters are studied to examine how MRA induced biomechanical changes will have an impact on the upper airway resistance. Low-dose computed tomography (CT) scans are made from 143 patients suffering from OSAHS. A baseline scan and a scan after mandibular repositioning (MR) are performed in order to study variations in parameters. It is found that MR using a simulation bite is able to induce resistance changes by changing the pharyngeal lumen. The change in minimal cross-sectional area is the best parameter to predict the change in upper airway resistance. Looking at baseline values, the ideal patients for MR induced resistance decrease seem to be women with short airways, high initial resistance and no baseline occlusion.
Keywords: A1 Journal article; Condensed Matter Theory (CMT); Vision lab; Laboratory Experimental Medicine and Pediatrics (LEMP); Translational Neurosciences (TNW)
Impact Factor: 2.664
Times cited: 23
DOI: 10.1016/j.jbiomech.2010.09.026
|
|
|
“Atom counting in HAADF STEM using a statistical model-based approach : methodology, possibilities, and inherent limitations”. de Backer A, Martinez GT, Rosenauer A, Van Aert S, Ultramicroscopy 134, 23 (2013). http://doi.org/10.1016/j.ultramic.2013.05.003
Abstract: In the present paper, a statistical model-based method to count the number of atoms of monotype crystalline nanostructures from high resolution high-angle annular dark-field (HAADF) scanning transmission electron microscopy (STEM) images is discussed in detail together with a thorough study on the possibilities and inherent limitations. In order to count the number of atoms, it is assumed that the total scattered intensity scales with the number of atoms per atom column. These intensities are quantitatively determined using model-based statistical parameter estimation theory. The distribution describing the probability that intensity values are generated by atomic columns containing a specific number of atoms is inferred on the basis of the experimental scattered intensities. Finally, the number of atoms per atom column is quantified using this estimated probability distribution. The number of atom columns available in the observed STEM image, the number of components in the estimated probability distribution, the width of the components of the probability distribution, and the typical shape of a criterion to assess the number of components in the probability distribution directly affect the accuracy and precision with which the number of atoms in a particular atom column can be estimated. It is shown that single atom sensitivity is feasible taking the latter aspects into consideration.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 48
DOI: 10.1016/j.ultramic.2013.05.003
|
|
|
“A case series on lung deposition analysis of inhaled medication using functional imaging based computational fluid dynamics in asthmatic patients : effect of upper airway morphology and comparison with in vivo data”. Vinchurkar S, De Backer L, Vos W, Van Holsbeke C, de Backer J, de Backer W, Inhalation Toxicology 24, 81 (2012). http://doi.org/10.3109/08958378.2011.644351
Abstract: Context: Asthma affects 20 million Americans resulting in an economic burden of approximately $18 billion in the US alone (Allergies and Asthma Foundation 2000; National Center for Environmental Health (NCEH) 1999). Research studies based on differences in patient-specific airway morphology for asthma and the associated effect on deposition of inhaled aerosols are currently not available in the literature. Therefore, the role of morphological variations such as upper airway (extrathoracic) occlusion is not well documented. Objective: Functional imaging based computational fluid dynamics (CFD) of the respiratory airways for five asthmatic subjects is performed in this study using computed tomography (CT) based patient-specific airway models and boundary conditions. Methods: CT scans for 5 asthma patients were used to reconstruct 3D lung models using segmentation software. An averaged inhalation profile and patient-specific lobar flow distribution were used to perform the simulation. The simulations were used to obtain deposition for BDP/Formoterol (R) HFA pMDI in the patient-specific airway models. Results: The lung deposition obtained using CFD was in excellent agreement with available in vivo data using the same product. Specifically, CFD resulted in 30% lung deposition, whereas in vivo lung deposition was reported to be approximately 31%. Conclusion: It was concluded that a combination of patient-specific airway models and lobar boundary conditions can be used to obtain accurate lung deposition estimates. Lower lung deposition can be expected for patients with higher extrathoracic resistance. Novel respiratory drug delivery devices need to accommodate population subgroups based on these morphological and anatomical differences in addition to subject age.
Keywords: A1 Journal article; Pharmacology. Therapy; Biophysics and Biomedical Physics; Condensed Matter Theory (CMT); Laboratory Experimental Medicine and Pediatrics (LEMP)
Impact Factor: 1.751
Times cited: 36
DOI: 10.3109/08958378.2011.644351
|
|
|
“Change in upper airway geometry between upright and supine position during tidal nasal breathing”. Van Holsbeke CS, Verhulst SL, Vos WG, de Backer JW, Vinchurkar SC, Verdonck PR, van Doorn JWD, Nadjmi N, de Backer WA, Journal Of Aerosol Medicine And Pulmonary Drug Delivery 27, 51 (2014). http://doi.org/10.1089/jamp.2012.1010
Keywords: A1 Journal article; Biophysics and Biomedical Physics; Condensed Matter Theory (CMT); Laboratory Experimental Medicine and Pediatrics (LEMP); Translational Neurosciences (TNW)
Impact Factor: 2.528
Times cited: 16
DOI: 10.1089/jamp.2012.1010
|
|
|
“Clinical applications of image-based airway computational fluid dynamics: assessment of inhalation medication and endobronchial devices”. de Backer JW, Vos WG, Germonpré, P, Salgado R, Parizel PM, de Backer W, Proceedings of the Society of Photo-optical Instrumentation Engineers 7262, 72621p (2009). http://doi.org/10.1117/12.811476
Abstract: Computational fluid dynamics (CFD) is a technique that is used increasingly in the biomedical field. Solving the flow equations numerically provides a convenient way to assess the efficiency of therapies and devices, ranging from cardiovascular stents and heart valves to hemodialysis workflows. Also in the respiratory field CFD has gained increasing interest, especially through the combination of three dimensional image reconstruction which results in highend patient-specific models. This paper provides an overview of clinical applications of CFD through image based modeling, resulting from recent studies performed in our center. We focused on two applications: assessment of the efficiency of inhalation medication and analysis of endobronchial valve placement. In the first application we assessed the mode of action of a novel bronchodilator in 10 treated patients and 4 controls. We assessed the local volume increase and resistance change based on the combination of imaging and CFD. We found a good correlation between the changes in volume and resistance coming from the CFD results and the clinical tests. In the second application we assessed the placement and effect of one way endobronchial valves on respiratory function in 6 patients. We found a strong patientspecific result of the therapy where in some patients the therapy resulted in complete atelectasis of the target lobe while in others the lobe remained inflated. We concluded from these applications that CFD can provide a better insight into clinically relevant therapies.
Keywords: A3 Journal article; Condensed Matter Theory (CMT); Antwerp Surgical Training, Anatomy and Research Centre (ASTARC); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1117/12.811476
|
|
|
“Computational fluid dynamics can detect changes in airway resistance in asthmatics after acute bronchodilation”. de Backer JW, Vos WG, Devolder A, Verhulst SL, Germonpré, P, Wuyts FL, Parizel PM, de Backer W, Journal of biomechanics 41, 106 (2008). http://doi.org/10.1016/j.jbiomech.2007.07.009
Keywords: A1 Journal article; Condensed Matter Theory (CMT); Antwerp Surgical Training, Anatomy and Research Centre (ASTARC); Laboratory Experimental Medicine and Pediatrics (LEMP)
Impact Factor: 2.664
Times cited: 53
DOI: 10.1016/j.jbiomech.2007.07.009
|
|
|
“Correlation between severity of sleep apnea and upper airway morphology based on advanced anatomical and functional imaging”. Vos W, de Backer J, Devolder A, Vanderveken O, Verhulst S, Salgado R, Germonpré, P, Partoens B, Wuyts F, Parizel P, de Backer W, Journal of biomechanics 40, 2207 (2007). http://doi.org/10.1016/j.jbiomech.2006.10.024
Keywords: A1 Journal article; Condensed Matter Theory (CMT); Antwerp Surgical Training, Anatomy and Research Centre (ASTARC); Laboratory Experimental Medicine and Pediatrics (LEMP); Translational Neurosciences (TNW)
Impact Factor: 2.664
Times cited: 86
DOI: 10.1016/j.jbiomech.2006.10.024
|
|
|
“Dose limited reliability of quantitative annular dark field scanning transmission electron microscopy for nano-particle atom-counting”. de Backer A, Martinez GT, MacArthur KE, Jones L, Béché, A, Nellist PD, Van Aert S, Ultramicroscopy 151, 56 (2015). http://doi.org/10.1016/j.ultramic.2014.11.028
Abstract: Quantitative annular dark field scanning transmission electron microscopy (ADF STEM) has become a powerful technique to characterise nano-particles on an atomic scale. Because of their limited size and beam sensitivity, the atomic structure of such particles may become extremely challenging to determine. Therefore keeping the incoming electron dose to a minimum is important. However, this may reduce the reliability of quantitative ADF STEM which will here be demonstrated for nano-particle atom-counting. Based on experimental ADF STEM images of a real industrial catalyst, we discuss the limits for counting the number of atoms in a projected atomic column with single atom sensitivity. We diagnose these limits by combining a thorough statistical method and detailed image simulations.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 29
DOI: 10.1016/j.ultramic.2014.11.028
|
|
|
“Effect of high-dose N-acetylcysteine on airway geometry, inflammation, and oxidative stress in COPD patients”. de Backer J, Vos W, Van Holsbeke C, Vinchurkar S, Claes R, Parizel PM, de Backer W, International Journal Of Chronic Obstructive Pulmonary Disease 8, 569 (2013). http://doi.org/10.2147/COPD.S49307
Abstract: Background: Previous studies have demonstrated the potential beneficial effect of N-acetylcysteine (NAC) in chronic obstructive pulmonary disease (COPD). However, the required dose and responder phenotype remain unclear. The current study investigated the effect of high-dose NAC on airway geometry, inflammation, and oxidative stress in COPD patients. Novel functional respiratory imaging methods combining multislice computed tomography images and computer-based flow simulations were used with high sensitivity for detecting changes induced by the therapy. Methods: Twelve patients with Global Initiative for Chronic Obstructive Lung Disease stage II COPD were randomized to receive NAC 1800 mg or placebo daily for 3 months and were then crossed over to the alternative treatment for a further 3 months. Results: Significant correlations were found between image-based resistance values and glutathione levels after treatment with NAC (P = 0.011) and glutathione peroxidase at baseline (P = 0.036). Image-based resistance values appeared to be a good predictor for glutathione peroxidase levels after NAC (P = 0.02), changes in glutathione peroxidase levels (P = 0.035), and reduction in lobar functional residual capacity levels (P = 0.00084). In the limited set of responders to NAC therapy, the changes in airway resistance were in the same order as changes induced by budesonide/formoterol. Conclusion: A combination of glutathione, glutathione peroxidase, and imaging parameters could potentially be used to phenotype COPD patients who would benefit from addition of NAC to their current therapy. The findings of this small pilot study need to be confirmed in a larger pivotal trial.
Keywords: A1 Journal article; Biophysics and Biomedical Physics; Condensed Matter Theory (CMT); Antwerp Surgical Training, Anatomy and Research Centre (ASTARC); Laboratory Experimental Medicine and Pediatrics (LEMP)
Impact Factor: 3.157
Times cited: 21
DOI: 10.2147/COPD.S49307
|
|
|
“The effect of probe inaccuracies on the quantitative model-based analysis of high angle annular dark field scanning transmission electron microscopy images”. Martinez GT, de Backer A, Rosenauer A, Verbeeck J, Van Aert S, Micron 63, 57 (2014). http://doi.org/10.1016/j.micron.2013.12.009
Abstract: Quantitative structural and chemical information can be obtained from high angle annular dark field scanning transmission electron microscopy (HAADF STEM) images when using statistical parameter estimation theory. In this approach, we assume an empirical parameterized imaging model for which the total scattered intensities of the atomic columns are estimated. These intensities can be related to the material structure or composition. Since the experimental probe profile is assumed to be known in the description of the imaging model, we will explore how the uncertainties in the probe profile affect the estimation of the total scattered intensities. Using multislice image simulations, we analyze this effect for Cs corrected and non-Cs corrected microscopes as a function of inaccuracies in cylindrically symmetric aberrations, such as defocus and spherical aberration of third and fifth order, and non-cylindrically symmetric aberrations, such as 2-fold and 3-fold astigmatism and coma.
Keywords: A1 Journal article; Engineering Management (ENM); Electron microscopy for materials research (EMAT)
Impact Factor: 1.98
Times cited: 25
DOI: 10.1016/j.micron.2013.12.009
|
|
|
de Backer W, Vos W, Van Holsbeke C, Vinchurkar S, Claes R, Hufkens A, Parizel PM, Bedert L, de Backer J (2014) The effect of roflumilast in addition to LABA/LAMA/ICS treatment in COPD patients. Copenhagen, 527–529
Keywords: L1 Letter to the editor; Biophysics and Biomedical Physics; Condensed Matter Theory (CMT); Antwerp Surgical Training, Anatomy and Research Centre (ASTARC); Laboratory Experimental Medicine and Pediatrics (LEMP)
Impact Factor: 10.569
Times cited: 26
DOI: 10.1183/09031936.00011714
|
|
|
“The effects of long-term noninvasive ventilation in hypercapnic COPD patients : a randomized controlled pilot study”. De Backer L, Vos W, Dieriks B, Daems D, Verhulst S, Vinchurkar S, Ides K, de Backer J, Germonpré, P, de Backer W, International journal of chronic obstructive pulmonary disease 6, 615 (2011). http://doi.org/10.2147/COPD.S22823
Abstract: Introduction: Noninvasive ventilation (NIV) is a well-established treatment for acute-on-chronic respiratory failure in hypercapnic COPD patients. Less is known about the effects of a long-term treatment with NIV in hypercapnic COPD patients and about the factors that may predict response in terms of improved oxygenation and lowered CO2 retention.Methods: In this study, we randomized 15 patients to a routine pharmacological treatment (n = 5, age 66 [standard deviation ± 6] years, FEV1 30.5 [±5.1] %pred, PaO2 65 [±6] mmHg, PaCO2 52.4 [±6.0] mmHg) or to a routine treatment and NIV (using the Synchrony BiPAP device [Respironics, Inc, Murrsville, PA]) (n = 10, age 65 [±7] years, FEV1 29.5 [±9.0] %pred, PaO2 59 [±13] mmHg, PaCO2 55.4 [±7.7] mmHg) for 6 months. We looked at arterial blood gasses, lung function parameters and performed a low-dose computed tomography of the thorax, which was later used for segmentation (providing lobe and airway volumes, iVlobe and iVaw) and post-processing with computer methods (providing airway resistance, iRaw) giving overall a functional image of the separate airways and lobes.Results: In both groups there was a nonsignificant change in FEV1 (NIV group 29.5 [9.0] to 38.5 [14.6] %pred, control group 30.5 [5.1] to 36.8 [8.7] mmHg). PaCO2 dropped significantly only in the NIV group (NIV: 55.4 [7.7] → 44.5 [4.70], P = 0.0076; control: 52.4 [6.0] → 47.6 [8.2], NS). Patients actively treated with NIV developed a more inhomogeneous redistribution of mass flow than control patients. Subsequent analysis indicated that in NIV-treated patients that improve their blood gases, mass flow was also redistributed towards areas with higher vessel density and less emphysema, indicating that flow was redistributed towards areas with better perfusion. There was a highly significant correlation between the % increase in mass flow towards lobes with a blood vessel density of >9% and the increase in PaO2. Improved ventilation–perfusion match and recruitment of previously occluded small airways can explain the improvement in blood gases.Conclusion: We can conclude that in hypercapnic COPD patients treated with long-term NIV over 6 months, a mass flow redistribution occurs, providing a better ventilation–perfusion match and hence better blood gases and lung function. Control patients improve homogeneously in iVaw and iRaw, without improvement in gas exchange since there is no improved ventilation/perfusion ratio or increased alveolar ventilation. These differences in response can be detected through functional imaging, which gives a more detailed report on regional lung volumes and resistances than classical lung function tests do. Possibly only patients with localized small airway disease are good candidates for long-term NIV treatment. To confirm this and to see if better arterial blood gases also lead to better health related quality of life and longer survival, we have to study a larger population.
Keywords: A1 Journal article; Condensed Matter Theory (CMT); Laboratory Experimental Medicine and Pediatrics (LEMP)
Impact Factor: 3.157
Times cited: 28
DOI: 10.2147/COPD.S22823
|
|
|
“Estimation of unknown structure parameters from high-resolution (S)TEM images : what are the limits?”.den Dekker AJ, Gonnissen J, de Backer A, Sijbers J, Van Aert S, Ultramicroscopy 134, 34 (2013). http://doi.org/10.1016/j.ultramic.2013.05.017
Abstract: Statistical parameter estimation theory is proposed as a quantitative method to measure unknown structure parameters from electron microscopy images. Images are then purely considered as data planes from which structure parameters have to be determined as accurately and precisely as possible using a parametric statistical model of the observations. For this purpose, an efficient algorithm is proposed for the estimation of atomic column positions and intensities from high angle annular dark field (HAADF) scanning transmission electron microscopy (STEM) images. Furthermore, the so-called CramérRao lower bound (CRLB) is reviewed to determine the limits to the precision with which continuous parameters such as atomic column positions and intensities can be estimated. Since this lower bound can only be derived for continuous parameters, alternative measures using the principles of detection theory are introduced for problems concerning the estimation of discrete parameters such as atomic numbers. An experimental case study is presented to show the practical use of these measures for the optimization of the experiment design if the purpose is to decide between the presence of specific atom types using STEM images.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 31
DOI: 10.1016/j.ultramic.2013.05.017
|
|
|
“Exit wave reconstruction from focal series of HRTEM images, single crystal XRD and total energy studies on SbxWO3+y (x\sim0.11)”. Klingstedt M, Sundberg M, Eriksson L, Haigh S, Kirkland A, Grüner D, de Backer A, Van Aert S, Tarasaki O, Zeitschrift für Kristallographie 227, 341 (2012). http://doi.org/10.1524/zkri.2012.1517
Abstract: A new tungsten bronze in the SbWO system has been prepared in a solid state reaction from Sb2O3, WO3 and W metal powder. The average structure was determined by single crystal X-ray diffraction. SbxWO3+y (x ∼ 0.11) crystallizes in the orthorhombic space group Pm21n (no. 31), a = 27.8135(9) Å, b = 7.3659(2) Å and c = 3.8672(1) Å. The structure belongs to the (n)-ITB class of intergrowth tungsten bronzes. It contains slabs of hexagonal channels formed by six WO6 octahedra. These slabs are separated by three layers of WO6 octahedra that are arranged in a WO3-type fashion. The WO6 octahedra share all vertices to build up a three-dimensional framework. The hexagonal channels are filled with Sb atoms to ∼80% and additional O atoms. The atoms are shifted out of the center of the channels. Exit-wave reconstruction of focal series of high resolution-transmission-electron-microscope (HRTEM) images combined with statistical paramäeter estimation techniques allowed to study local ordering in the channels. Sb atoms in neighbouring channels tend to be displaced in the same direction, which is in agreement with total energy calculations on ordered structure models, but the ratio of the occupation of the two possible Sb sites varies from channel to channel. The structure of SbxWO3+y exhibits pronounced local modulations.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 3.179
Times cited: 4
DOI: 10.1524/zkri.2012.1517
|
|
|
“Flow analyses in the lower airways: patient-specific model and boundary conditions”. de Backer JW, Vos WG, Gorlé, CD, Germonpré, P, Partoens B, Wuyts FL, Parizel PM, de Backer W, Medical engineering and physics 30, 872 (2008). http://doi.org/10.1016/j.medengphy.2007.11.002
Abstract: Computational fluid dynamics (CFD) is increasingly applied in the respiratory domain. The ability to simulate the flow through a bifurcating tubular system has increased the insight into the internal flow dynamics and the particular characteristics of respiratory flows such as secondary motions and inertial effects. The next step in the evolution is to apply the technique to patient-specific cases, in order to provide more information about pathological airways. This study presents a patient-specific approach where both the geometry and the boundary conditions (BC) are based on individual imaging methods using computed tomography (CT). The internal flow distribution of a 73-year-old female suffering from chronic obstructive pulmonary disease (COPD) is assessed. The validation is performed through the comparison of lung ventilation with gamma scintigraphy. The results show that in order to obtain agreement within the accuracy limits of the gamma scintigraphy scan, both the patient-specific geometry and the BC (driving pressure) play a crucial role. A minimal invasive test (CT scan) supplied enough information to perform an accurate CFD analysis. In the end it was possible to capture the pathological features of the respiratory system using the imaging and computational fluid dynamics techniques. This brings the introduction of this new technique in the clinical practice one step closer.
Keywords: A1 Journal article; Condensed Matter Theory (CMT); Antwerp Surgical Training, Anatomy and Research Centre (ASTARC); Laboratory Experimental Medicine and Pediatrics (LEMP)
Impact Factor: 1.819
Times cited: 82
DOI: 10.1016/j.medengphy.2007.11.002
|
|
|
“Functional imaging to predict treatment success of mandibular advancement devices in sleep-disordered breathing”. de Backer J, Vanderveken O, Vos W, Devolder A, Verhulst S, Verbraecken J Antwerpen, page 141 (2008).
Keywords: H3 Book chapter; Condensed Matter Theory (CMT); Laboratory Experimental Medicine and Pediatrics (LEMP); Translational Neurosciences (TNW)
|
|
|
“Functional imaging using computational fluid dynamics to predict treatment success of mandibular advancement devices in sleep-disordered breathing”. de Backer JW, Vanderveken OM, Vos WG, Devolder A, Verhulst SL, Verbraecken JA, Parizel PM, Braem MJ, van de Heyning PH, de Backer WA, Journal of biomechanics 40, 3708 (2007). http://doi.org/10.1016/j.jbiomech.2007.06.022
Keywords: A1 Journal article; Condensed Matter Theory (CMT); Antwerp Surgical Training, Anatomy and Research Centre (ASTARC); Laboratory Experimental Medicine and Pediatrics (LEMP); Translational Neurosciences (TNW)
Impact Factor: 2.664
Times cited: 66
DOI: 10.1016/j.jbiomech.2007.06.022
|
|
|
“Functional imaging using computer methods to compare the effect of salbutamol and ipratropium bromide in patient-specific airway models of COPD”. De Backer LA, Vos WG, Salgado R, de Backer JW, Devolder A, Verhulst SL, Claes R, Germonpré, PR, de Backer WA, International journal of chronic obstructive pulmonary disease 6, 637 (2011). http://doi.org/10.2147/COPD.S21917
Abstract: Background: Salbutamol and ipratropium bromide improve lung function in patients with chronic obstructive pulmonary disease (COPD). However, their bronchodilating effect has not yet been compared in the central and distal airways. Functional imaging using computational fluid dynamics offers the possibility of making such a comparison. The objective of this study was to assess the effects of salbutamol and ipratropium bromide on the geometry and computational fluid dynamics-based resistance of the central and distal airways.Methods: Five patients with Global Initiative for Chronic Obstructive Lung Disease Stage III COPD were randomized to a single dose of salbutamol or ipratropium bromide in a crossover manner with a 1-week interval between treatments. Patients underwent lung function testing and a multislice computed tomography scan of the thorax that was used for functional imaging. Two hours after dosing, the patients again underwent lung function tests and repeat computed tomography.Results: Lung function parameters, including forced expiratory volume in 1 second, vital capacity, overall airway resistance, and specific airway resistance, changed significantly after administration of each product. On functional imaging, the bronchodilating effect was greater in the distal airways, with a corresponding drop in airway resistance, compared with the central airways. Salbutamol and ipratropium bromide were equally effective at first glance when looking at lung function tests, but when viewed in more detail with functional imaging, hyporesponsiveness could be shown for salbutamol in one patient. Salbutamol was more effective in the other patients.Conclusion: This pilot study gives an innovative insight into the modes of action of salbutamol and ipratropium bromide in patients with COPD, using the new techniques of functional imaging and computational fluid dynamics.
Keywords: A1 Journal article; Condensed Matter Theory (CMT); Vision lab; Laboratory Experimental Medicine and Pediatrics (LEMP)
Impact Factor: 3.157
Times cited: 25
DOI: 10.2147/COPD.S21917
|
|
|
“Functional respiratory imaging as a tool to assess upper airway patency in children with obstructive sleep apnea”. Van Holsbeke C, Vos W, van Hoorenbeeck K, Boudewyns A, Salgado R, Verdonck PR, Ramet J, de Backer J, De Backer W, Verhulst SL, Sleep Medicine 14, 433 (2013). http://doi.org/10.1016/j.sleep.2012.12.005
Abstract: Objective: We aim to investigate if anatomical and functional properties of the upper airway using computerized 3D models derived from computed tomography (CT) scans better predict obstructive sleep apnea (OSA) severity than standard clinical markers. Methods: Consecutive children with suspected OSA underwent polysomnography, clinical assessment of upper airway patency, and a CT scan while awake. A three-dimensional (3D) reconstruction of the pharyngeal airway was built from these images, and computational fluid dynamics modeling of low inspiratory flow was performed using open-source software. Results: Thirty-three children were included (23 boys; mean age, was 6.0 +/- 3.2 y). OSA was diagnosed in 23 patients. Children with OSA had a significantly lower volume of the overlap region between tonsils and the adenoids (median volume, 1408 mm compared to 2173 mm; p = 0.04), a lower mean cross-sectional area at this location (median volume, 69.3 mm(2) compared to 114.3 mm(2); p = 0.04), and a lower minimal cross-sectional area (median volume, 17.9 mm(2) compared to 25.9 mm(2); p = 0.05). Various significant correlations were found between several imaging parameters and the severity of OSA, most pronounced for upper airway conductance (r = -0.46) (p < 0.01) for correlation between upper airway conductance and the apnea-hypopnea index. No differences or significant correlations were observed with clinical parameters of upper airway patency. Preliminary data after treatment showed that none of the patients with residual OSA had their smallest cross-sectional area located in segment 3, and this frequency was significantly lower than in their peers whose sleep study normalized (64%; p = 0.05). Conclusion: Functional imaging parameters are highly correlated with OSA severity and are a more powerful correlate than clinical scores of upper airway patency. Preliminary data also showed that we could identify differences in the upper airway of those subjects who did not benefit from a local upper airway treatment. (c) 2013 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Condensed Matter Theory (CMT); Laboratory Experimental Medicine and Pediatrics (LEMP)
Impact Factor: 3.391
Times cited: 18
DOI: 10.1016/j.sleep.2012.12.005
|
|
|
“Functional Respiratory Imaging as a tool to personalize respiratory treatment in subjects with unilateral diaphragmatic paralysis”. Van Holsbeke CS, Leemans G, Vos WG, de Backer JW, Vinchurkar SC, Geldof M, Verdonck PR, Parizel PM, van Schil PE, de Backer WA, Respiratory care , 1 (2013). http://doi.org/10.4187/respcare.02756
Abstract: In two subjects with a unilateral diaphragmatic paralysis and complaints of dyspnea, a completely different treatment approach was chosen despite similar anatomical and physiological abnormalities. These decisions were supported by the results generated by Functional Respiratory Imaging (FRI). FRI was able to generate functional information with respect to lobar ventilation and local drug deposition. In one subject, it was found that some lobes were poorly ventilated and drug deposition simulation showed that some regions were undertreated. This subject underwent a diaphragm plication to restore the ventilation. In the other subject, it was found that all lobes were still ventilated. A conservative approach with regular follow-up was chosen to wait for spontaneous recovery of the diaphragmatic function. Both subjects improved subjectively and objectively. These cases demonstrate how novel medical imaging techniques such as FRI can be used to personalize respiratory treatment in subjects with unilateral diaphragmatic paralysis.
Keywords: A1 Journal article; Condensed Matter Theory (CMT); Antwerp Surgical Training, Anatomy and Research Centre (ASTARC); Laboratory Experimental Medicine and Pediatrics (LEMP)
Impact Factor: 1.733
Times cited: 5
DOI: 10.4187/respcare.02756
|
|
|
“High precision measurements of atom column positions using model-based exit wave reconstruction”. de Backer A, Van Aert S, van Dyck D, Ultramicroscopy 111, 1475 (2011). http://doi.org/10.1016/j.ultramic.2011.07.002
Abstract: In this paper, it has been investigated how to measure atom column positions as accurately and precisely as possible using a focal series of images. In theory, it is expected that the precision would considerably improve using a maximum likelihood estimator based on the full series of focal images. As such, the theoretical lower bound on the variances of the unknown atom column positions can be attained. However, this approach is numerically demanding. Therefore, maximum likelihood estimation has been compared with the results obtained by fitting a model to a reconstructed exit wave rather than to the full series of focal images. Hence, a real space model-based exit wave reconstruction technique based on the channelling theory is introduced. Simulations show that the reconstructed complex exit wave contains the same amount of information concerning the atom column positions as the full series of focal images. Only for thin samples, which act as weak phase objects, this information can be retrieved from the phase of the reconstructed complex exit wave.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 8
DOI: 10.1016/j.ultramic.2011.07.002
|
|
|
“Klinische semiologie en radiologie”. Parizel PM, Corthouts B, Snoeckx A, de Backer J, de Backer W Acco, Leuven, page 133 (2007).
Keywords: H3 Book chapter; Condensed Matter Theory (CMT); Antwerp Surgical Training, Anatomy and Research Centre (ASTARC); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“Advanced electron crystallography through model-based imaging”. Van Aert S, De Backer A, Martinez GT, den Dekker AJ, Van Dyck D, Bals S, Van Tendeloo G, IUCrJ 3, 71 (2016). http://doi.org/10.1107/S2052252515019727
Abstract: The increasing need for precise determination of the atomic arrangement of non-periodic structures in materials design and the control of nanostructures explains the growing interest in quantitative transmission electron microscopy. The aim is to extract precise and accurate numbers for unknown structure parameters including atomic positions, chemical concentrations and atomic numbers. For this purpose, statistical parameter estimation theory has been shown to provide reliable results. In this theory, observations are considered purely as data planes, from which structure parameters have to be determined using a parametric model describing the images. As such, the positions of atom columns can be measured with a precision of the order of a few picometres, even though the resolution of the electron microscope is still one or two orders of magnitude larger. Moreover, small differences in average atomic number, which cannot be distinguished visually, can be quantified using high-angle annular dark-field scanning transmission electron microscopy images. In addition, this theory allows one to measure compositional changes at interfaces, to count atoms with single-atom sensitivity, and to reconstruct atomic structures in three dimensions. This feature article brings the reader up to date, summarizing the underlying theory and highlighting some of the recent applications of quantitative model-based transmisson electron microscopy.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab; Engineering Management (ENM)
Impact Factor: 5.793
Times cited: 30
DOI: 10.1107/S2052252515019727
|
|