|
“A general-purpose interface between fortran and the low-level functions of the ibm-pc”. Janssens K, van Espen P, Trends in analytical chemistry 7, 128 (1988). http://doi.org/10.1016/0165-9936(88)87009-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0165-9936(88)87009-2
|
|
|
“A microanalytical study of the gills of aluminium-exposed rainbow trout (Salmo gairdneri)”. Goossenaerts C, Van Grieken R, Jacob W, Witters H, Vanderborght O, International journal of environmental analytical chemistry 34, 227 (1988). http://doi.org/10.1080/03067319808026840
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067319808026840
|
|
|
“A Monte Carlo model for studying the microheterogeneity of trace elements in reference materials by means of synchrotron microscopic X-ray fluorescence”. Kempenaers L, Janssens K, Vincze L, Vekemans B, Somogyi A, Drakopoulos M, Simionovici AS, Adams F, Analytical chemistry 74, 5017 (2002). http://doi.org/10.1021/AC025662G
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 21
DOI: 10.1021/AC025662G
|
|
|
“A Monte Carlo program for quantitative electron-induced x-ray analysis of individual particles”. Ro C-U, Osán J, Szalóki I, de Hoog J, Worobiec A, Van Grieken R, Analytical chemistry 75, 851 (2003). http://doi.org/10.1021/AC025973R
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC025973R
|
|
|
“Absorption correction for X-ray-fluorescence analysis of aerosol loaded filters”. Adams FC, Van Grieken RE, Analytical chemistry 47, 1767 (1975). http://doi.org/10.1021/AC60361A040
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC60361A040
|
|
|
“Absorption correction in electron probe x-ray microanalysis of thin samples”. Markowicz AA, Storms HM, Van Grieken RE, Analytical chemistry 58, 1282 (1986). http://doi.org/10.1021/AC00298A003
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00298A003
|
|
|
“Absorption correction via scattered radiation in energy-dispersive X-ray fluorescence analysis for samples of variable composition and thickness”. Van Dyck PM, Van Grieken RE, Analytical chemistry 52, 1859 (1980). http://doi.org/10.1021/AC50062A020
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50062A020
|
|
|
“Advantages of combined mu-XRF and mu-XRD for phase characterization of Ti-B-C ceramics compared with conventional X-ray diffraction”. Jaroszewicz J, de Nolf W, Janssens K, Michalski A, Falkenberg G, Analytical and bioanalytical chemistry 391, 1129 (2008). http://doi.org/10.1007/S00216-008-2097-6
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.431
Times cited: 7
DOI: 10.1007/S00216-008-2097-6
|
|
|
“Airborne particles in the Miyagi Museum of Art in Sendai, Japan, studied by electron probe X-ray microanalysis and energy dispersive X-ray fluorescence analysis”. Injuk J, Osán J, Van Grieken R, Tsuji K, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 18, 561 (2002). http://doi.org/10.2116/ANALSCI.18.561
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.2116/ANALSCI.18.561
|
|
|
“Amperometric flow-injection analysis of phenols induced by reactive oxygen species generated under daylight irradiation of titania impregnated with horseradish peroxidase”. Rahemi V, Trashin S, Hafideddine Z, Van Doorslaer S, Meynen V, Gorton L, De Wael K, Analytical Chemistry 92, 3643 (2020). http://doi.org/10.1021/acs.analchem.9b04617
Abstract: Titanium dioxide (TiO2) is a unique material for biosensing applications due to its capability of hosting enzymes. For the first time, we show that TiO2 can accumulate reactive oxygen species (ROS) under daylight irradiation and can support the catalytic cycle of horseradish peroxidase (HRP) without the need of H2O2 to be present in the solution. Phenolic compounds, such as hydroquinone (HQ) and 4-aminophenol (4-AP), were detected amperometrically in flow-injection analysis (FIA) mode via the use of an electrode modified with TiO2 impregnated with HRP. In contrast to the conventional detection scheme, no H2O2 was added to the analyte solution. Basically, the inherited ability of TiO2 to generate reactive oxygen species is used as a strategy to avoid adding H2O2 in the solution during the detection of phenolic compounds. Electron paramagnetic resonance (EPR) spectroscopy indicates the presence of ROS on titania which, in interaction with HRP, initiate the electrocatalysis toward phenolic compounds. The amperometric response to 4-AP was linear in the concentration range between 0.05 and 2 μM. The sensitivity was 0.51 A M–1 cm–2, and the limit of detection (LOD) 26 nM. The proposed sensor design opens new opportunities for the detection of phenolic traces by HRP-based electrochemical biosensors, yet in a more straightforward and sensitive way following green chemistry principles of avoiding the use of reactive and harmful chemical, such as H2O2.
Keywords: A1 Journal article; Laboratory of adsorption and catalysis (LADCA); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 7.4
Times cited: 3
DOI: 10.1021/acs.analchem.9b04617
|
|
|
“An adhesive conducting electrode material based on commercial mesoporous titanium dioxide as a support for Horseradish peroxidase for bioelectrochemical applications”. Rahemi V, Trashin S, Meynen V, De Wael K, Talanta : the international journal of pure and applied analytical chemistry 146, 689 (2016). http://doi.org/10.1016/J.TALANTA.2015.06.041
Abstract: An adhesive conducting electrode material containing of graphite, biocompatible ion exchange polymer nafion® and commercial mesoporous TiO2 impregnated with horseradish peroxidase (HRP) is prepared and characterized by amperometric, UVvis and N2 sorption methods. The factors influencing the performance of the resulting biosensor are studied in detail. The optimal electrode material consists of 45% graphite, 50% impregnated HRPTiO2 and 5% nafion®. The optimum conditions for H2O2 reduction are an applied potential of 0.3 V and 0.1 mM hydroquinone. Sensitivity and limit of detection in the optimum conditions are 1 A M−1 cm−2 and 1 µM correspondingly. The N2 sorption results show that the pore volume of TiO2 decreases sharply upon adsorption of HRP. The preparation process of the proposed enzyme electrode is straightforward and potentially can be used for preparation of carbon paste electrodes for bioelectrochemical detections.
Keywords: A1 Journal article; Laboratory of adsorption and catalysis (LADCA); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.162
Times cited: 7
DOI: 10.1016/J.TALANTA.2015.06.041
|
|
|
“An expert system for chemical speciation of individual particles using low-Z particle electron probe X-ray microanalysis data”. Ro C-U, Kim HK, Van Grieken R, Analytical chemistry 76, 1322 (2004). http://doi.org/10.1021/AC035149I
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC035149I
|
|
|
“Analysis of Short-Lived Reactive Species in Plasma–Air–Water Systems: The Dos and the Do Nots”. Gorbanev Y, Privat-Maldonado A, Bogaerts A, Analytical Chemistry 90, 13151 (2018). http://doi.org/10.1021/acs.analchem.8b03336
Abstract: This Feature addresses the analysis of the reactive species generated by nonthermal atmospheric
pressure plasmas, which are widely employed in industrial and biomedical research, as well as first
clinical applications. We summarize the progress in detection of plasma-generated short-lived
reactive oxygen and nitrogen species in aqueous solutions, discuss the potential and limitations of
various analytical methods in plasma−liquid systems, and provide an outlook on the possible future
research goals in development of short-lived reactive species analysis methods for a general
nonspecialist audience.
Keywords: A1 Journal Article; Plasma, laser ablation and surface modeling Antwerp (PLASMANT) ;
Impact Factor: 6.32
Times cited: 17
DOI: 10.1021/acs.analchem.8b03336
|
|
|
“Analytical techniques for the detection of amphetamine-type substances in different matrices : a comprehensive review”. Drăgan A-M, Parrilla M, Feier B, Oprean R, Cristea C, De Wael K, Trac-Trends In Analytical Chemistry 145, 116447 (2021). http://doi.org/10.1016/J.TRAC.2021.116447
Abstract: This current review focuses on contributions to amphetamine-type substances (ATS) analysis. This type of synthetic illicit drugs has been increasingly present worldwide reaching 5% of the market on illicit drugs in 2019. The increment of their production in many clandestine laboratories and easy distribution among society are two of the main concerns towards the battle against synthetic drugs. Therefore, the first part of this review details the classification and mechanism of action of ATS in the human body. Second, the pharmacological and toxicological effects of ATS on human health are described to motivate the need of early detection of ATS. Subsequently, the most used laboratory-based and portable methods are presented and critically discussed along the review. Finally, a careful discussion on the advantages and disadvantages of portable techniques employed on the field are addressed as potential tools for on-site ATS detection by law enforcement officers.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 8.442
DOI: 10.1016/J.TRAC.2021.116447
|
|
|
“Applications of micro-analysis to individual environmental particles”. Jambers W, de Bock L, Van Grieken R, Fresenius' journal of analytical chemistry 355, 521 (1996). http://doi.org/10.1007/S0021663550521
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S0021663550521
|
|
|
“Aptasensing of chloramphenicol in the presence of its analogues : reaching the maximum residue limit”. Pilehvar S, Mehta J, Dardenne F, Robbens J, Blust R, De Wael K, Analytical chemistry 84, 6753 (2012). http://doi.org/10.1021/AC3012522
Abstract: A novel label-free folding induced aptamer-based electrochemical biosensor for the detection of chloramphenicol (CAP) in the presence of its analogues has been developed. CAP is a broad-spectrum antibiotic which has lost its favor due to its serious adverse toxic effects on human health. Aptamers are artificial nucleic acid ligands (ssDNA or RNA) able to specifically recognize a target such as CAP. In this article, the aptamers are fixed onto a gold electrode surface by a self-assembly approach. In the presence of CAP, the unfolded ssDNA on the electrode surface changes to a hairpin structure bringing the target molecules close to the surface and trigger electron transfer. Detection limits were determined to be 1.6×10-9 mol L-1. In addition, thiamphenicol (TAP) and florfenicol (FF), antibiotics with a similar structure to CAP, did not influence the performance of the aptasensor, suggesting a good selectivity of the CAP-aptasensor. Simplicity and lower detection limit (because of the home-selected aptamers) make that the electrochemical aptasensor is suitable for practical use in the detection of CAP in milk samples.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 68
DOI: 10.1021/AC3012522
|
|
|
“Assessing the molecular weight of a conducting polymer by grazing emission XRF”. Blockhuys F, Claes M, Van Grieken R, Geise HJ, Analytical chemistry 72, 3366 (2000). http://doi.org/10.1021/AC990877K
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC990877K
|
|
|
“Atomic number correction in electron probe X-ray microanalysis of curved samples and particles”. Markowicz AA, Van Grieken RE, Analytical chemistry 56, 2798 (1984). http://doi.org/10.1021/AC00278A036
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00278A036
|
|
|
“Atomic spectroscopy”. Bings NH, Bogaerts A, Broekaert JAC, Analytical chemistry 85, 670 (2013). http://doi.org/10.1021/ac3031459
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 29
DOI: 10.1021/ac3031459
|
|
|
“Atomic spectroscopy”. Bings NH, Bogaerts A, Broekaert JAC, Analytical chemistry 80, 4317 (2008). http://doi.org/10.1021/ac8006297
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 53
DOI: 10.1021/ac8006297
|
|
|
“Atomic spectroscopy”. Bings NH, Bogaerts A, Broekaert JAC, Analytical chemistry 78, 3917 (2006). http://doi.org/10.1021/ac060597m
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 112
DOI: 10.1021/ac060597m
|
|
|
“Atomic spectroscopy”. Bings NH, Bogaerts A, Broekaert JAC, Analytical chemistry 76, 3313 (2004). http://doi.org/10.1021/ac040052x
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 32
DOI: 10.1021/ac040052x
|
|
|
“Atomic spectroscopy”. Bings NH, Bogaerts A, Broekaert JAC, Analytical chemistry 74, 2691 (2002). http://doi.org/10.1021/ac020190r
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 18
DOI: 10.1021/ac020190r
|
|
|
“Atomic spectroscopy: a review”. Bings NH, Bogaerts A, Broekaert JAC, Analytical chemistry 82, 4653 (2010). http://doi.org/10.1021/ac1010469
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 65
DOI: 10.1021/ac1010469
|
|
|
“Automated particle analysis of populations of silver halide microcrystals by electron probe microanalysis under cryogenic conditions”. Gregory CL, Nullens HA, Gijbels RH, van Espen PJ, Geuens I, de Keyzer R, Analytical chemistry 70, 2551 (1998). http://doi.org/10.1021/ac9710644
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Chemometrics (Mitac 3)
Impact Factor: 6.32
Times cited: 12
DOI: 10.1021/ac9710644
|
|
|
“Bremsstrahlung background in electron-probe X-ray-microanalysis of thin films”. Markowicz AA, Storms HM, Van Grieken RE, Analytical chemistry 57, 2885 (1985). http://doi.org/10.1021/AC00291A032
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00291A032
|
|
|
“Cephalosporin antibiotics : electrochemical fingerprints and core structure reactions investigated by LC-MSMS”. Sleegers N, van Nuijs ALN, van den Berg M, De Wael K, Analytical chemistry 91, 2035 (2019). http://doi.org/10.1021/ACS.ANALCHEM.8B04487
Abstract: Electrochemistry and exploiting electrochemical fingerprints is a potent approach to address newly emerging surveillance needs, for instance for antibiotics. However, a comprehensive insight in the electrochemical oxidation behaviour and mechanism is re-quired for this sensing strategy. To address the lack in knowledge of the voltammetric behaviour of the cephalosporins antibiotics, a selection of cephalosporin antibiotics and two main intermediates were subjected to an electrochemical study of their redox behaviour by means of pulsed voltammetric techniques and small-scale electrolysis combined with HPLC-MS/MS analyses. Sur-prisingly, the detected oxidation products did not fit the earlier suggested oxidation of the sulfur group to the corresponding sul-foxide. The influence of different side chains, both at the three and the seven position of the β-lactam core structure on the elec-trochemical fingerprint were investigated. Additional oxidation signals at lower potentials were elucidated and linked to different side chains. These signals were further exploited to allow simultaneous detection of different cephalosporins in one voltammetric sweep. These fundamental insights can become the building blocks for an new on-site screening method.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre
Impact Factor: 6.32
Times cited: 6
DOI: 10.1021/ACS.ANALCHEM.8B04487
|
|
|
“Characterization of a 2,2'-diaminodiethylamine-cellulose filter toward metal cation extraction”. Smits JA, Van Grieken RE, Analytical chemistry 52, 1479 (1980). http://doi.org/10.1021/AC50059A022
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50059A022
|
|
|
“Characterization of a degraded cadmium yellow (CdS) pigment in an oil painting by means of synchrotron radiation based X-ray techniques”. van der Snickt G, Dik J, Cotte M, Janssens K, Jaroszewicz J, de Nolf W, Groenewegen J, van der Loeff L, Analytical chemistry 81, 2600 (2009). http://doi.org/10.1021/AC802518Z
Abstract: On several paintings of James Ensor (1860−1949), a gradual fading of originally bright yellow areas, painted with the pigment cadmium yellow (CdS), is observed. Additionally, in some areas exposed to light, the formation of small white-colored globules on top of the original paint surface is observed. In this paper the chemical transformation leading to the color change and to the formation of the globules is elucidated. Microscopic X-ray absorption near-edge spectroscopy (ì-XANES) experiments show that sulfur, originally present in sulfidic form (S2−), is oxidized during the transformation to the sulfate form (S6+). Upon formation (at or immediately below the surface), the highly soluble cadmium sulfate is assumed to be transported to the surface in solution and reprecipitates there, forming the whitish globules. The presence of cadmium sulfate (CdSO4·2H2O) and ammonium cadmium sulfate [(NH4)2Cd(SO4)2] at the surface is confirmed by microscopic X-ray diffraction measurements, where the latter salt is suspected to result from a secondary reaction of cadmium sulfate with ammonia. Measurements performed on cross sections reveal that the oxidation front has penetrated into the yellow paint down to ca. 1−2 ìm. The morphology and elemental distribution of the paint and degradation product were examined by means of scanning electron microscopy equipped with an energy-dispersive spectrometer (SEM-EDS) and synchrotron radiation based micro-X-ray fluorescence spectrometry (SR ì-XRF). In addition, ultraviolet-induced visible fluorescence photography (UIVFP) revealed itself to be a straightforward technique for documenting the occurrence of this specific kind of degradation on a macroscale by painting conservators.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 91
DOI: 10.1021/AC802518Z
|
|
|
“Characterization of aerosol-associated lead by DPASV and LAMMA”. Wonders JHAM, Houweling S, de Bont FAJ, van Leeuwen HP, Eeckhaoudt SM, Van Grieken R, International journal of environmental analytical chemistry 56, 193 (1994). http://doi.org/10.1080/03067319408034100
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067319408034100
|
|