toggle visibility
Search within Results:
Display Options:

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Vanderborght, B.M.; Van Grieken, R.E. doi  openurl
  Title Trace metal analysis of water containing humic substances by X-ray fluorescence Type A1 Journal article
  Year (down) 1978 Publication International journal of environmental analytical chemistry Abbreviated Journal  
  Volume 5 Issue 3 Pages 221-237  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Chelation by oxine followed by adsorption on activated carbon results in the efficient collection of many trace metal ions, independent of the trace metal concentration and of high alkali and alkaline earth ion abundances. Preconcentration factors around 10000 are often achieved. When this preconcentration procedure is combined with energy-dispersive X-ray fluorescence, accurate and precise analysis can be carried out, as was proven in several experiments. The technique can also be applied for the determination of divalent ions in natural waters containing up to 10 ppm of humic substances. Trivalent ions can quantitatively be collected from natural water provided suKicient activated carbon is added. Omitting the oxine chelation prior to the activated carbon adsorption step still results in collection of a sometimes important fraction of the trace metal ions from natural waters. This is related to organically bound or colloidal forms of the trace metals.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1978FR88000005 Publication Date 2007-07-07  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0306-7319 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116570 Serial 8692  
Permanent link to this record
 

 
Author Van Grieken, R.E.; Bresseleers, C.M.; Vanderborght, B.M. doi  openurl
  Title Chelex-100 ion-exchange filter membranes for preconcentration in x-ray-fluorescence analysis of water Type A1 Journal article
  Year (down) 1977 Publication Analytical chemistry Abbreviated Journal  
  Volume 49 Issue 9 Pages 1326-1331  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1977DP25600011 Publication Date 2005-03-08  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2700; 5206-882x ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:113632 Serial 7639  
Permanent link to this record
 

 
Author Vanderborght, B.M.; Van Grieken, R.E. openurl 
  Title Enrichment of trace metals in water by adsorption on activated carbon Type A1 Journal article
  Year (down) 1977 Publication Analytical chemistry Abbreviated Journal  
  Volume 49 Issue 2 Pages 311-316  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos Publication Date  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2700; 5206-882x ISBN Additional Links UA library record  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116513 Serial 7923  
Permanent link to this record
 

 
Author Adams, F.C.; Van Grieken, R.E. doi  openurl
  Title Absorption correction for X-ray-fluorescence analysis of aerosol loaded filters Type A1 Journal article
  Year (down) 1975 Publication Analytical chemistry Abbreviated Journal  
  Volume 47 Issue 11 Pages 1767-1773  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1975AN45700013 Publication Date 2005-03-08  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2700; 5206-882x ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:113639 Serial 7408  
Permanent link to this record
 

 
Author Johansson, T.B.; Van Grieken, R.E.; Nelson, J.W.; Winchester, J.W. doi  openurl
  Title Elemental trace analysis of small samples by proton-induced X-ray-emission Type A1 Journal article
  Year (down) 1975 Publication Analytical chemistry Abbreviated Journal  
  Volume 47 Issue 6 Pages 855-860  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1975AA02900016 Publication Date 2005-03-08  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2700; 5206-882x ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:113638 Serial 7895  
Permanent link to this record
 

 
Author Van Grieken, R.; Speecke, A.; Hoste, J. doi  openurl
  Title Geometry errors in 14 MeV neutron activation analysis Type A3 Journal article
  Year (down) 1973 Publication Journal of radioanalytical chemistry Abbreviated Journal  
  Volume 13 Issue 1 Pages 225-233  
  Keywords A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract The effects of inaccurate sample sizes and sample positioning on 14 MeV neutron activation analysis results are estimated for 30, 20 and 10 mm diameter targets. It appears that axial positioning is the most critical parameter and that using a larger tritium target will yield an overall improvement of the reproducibility.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos Publication Date 2006-10-11  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0134-0719; 2064-2857 ISBN Additional Links UA library record  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116453 Serial 7999  
Permanent link to this record
 

 
Author Van Grieken, R.; Speecke, A.; Hoste, J. doi  openurl
  Title Spatial neutron flux distributions around A 14 MeV neutron generator Type A3 Journal article
  Year (down) 1972 Publication Journal of radioanalytical chemistry Abbreviated Journal  
  Volume 10 Issue 1 Pages 95-104  
  Keywords A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract The neutron flux distribution in the vicinity of 30, 20 and 10 mm diameter targets is measured by irradiating concentric ring-type iron monitors at different distances from the target and counting the induced56Mn activity. Considering the many uncertainties, satisfactory agreement was found between theory and experiment.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos Publication Date 2006-11-07  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0134-0719; 2064-2857 ISBN Additional Links UA library record  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116452 Serial 8567  
Permanent link to this record
 

 
Author Van Schandevijl, R.; Van Grieken, R.; Hoste, J. doi  openurl
  Title The half-life of 28Al Type A3 Journal article
  Year (down) 1971 Publication Journal of radioanalytical chemistry Abbreviated Journal  
  Volume 9 Issue 1 Pages 55-60  
  Keywords A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract The half-life of28Al was redetermined on aluminium samples of different origin. Three different counting techniques were applied. The availability of highly purified samples (up to 99.9999%), the use of very fast electronic counting equipment and a complete automatisation allowed a good precision to be obtained in the final result of 2.2405 min.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos Publication Date 2006-10-11  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0134-0719; 2064-2857 ISBN Additional Links UA library record  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116451 Serial 8016  
Permanent link to this record
 

 
Author Van Grieken, R.; Speecke, A.; Hoste, J. doi  openurl
  Title Simultaneous determination of silicon and phosphorus in cast iron by 14 MeV neutron activation analysis Type A3 Journal article
  Year (down) 1970 Publication Journal of radioanalytical chemistry Abbreviated Journal  
  Volume 6 Issue 2 Pages 385-398  
  Keywords A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract A fast (10 min), non-destructive simultaneous determination of silicon and phosphorus in cast iron and steel by 14 MeV neutron activation was developed. The 1.78 MeV28Al activity (T=2.24 min) induced by the reaction28Si(n, p)28Al is counted on a NaI(Tl) detector. Two measurements are made to correct for the 1.81 MeV56Mn activity (T=2.58 hr) from the iron matrix. However,28Al is also produced via31P(n, α)28Al. By (n, 2n) reaction, phosphorus yields also30P (T=2.6 min), the 0.511 MeV annihilation radiation of which is counted by two opposite NaI(Tl) detectors in coincidence. Again, two successive coincidence measurements are carried out in order to take into account the53Fe activity (β+; T=8.9 min) from54Fe(n, 2n)53Fe. The28Al measurement is appropriately corrected via the computed phosphorus content. An oxygen flux monitor was used to normalize to the same flux. Nuclear interferences have been examined. Special attention has been paid to the presence of copper. The standard deviation for phosphorus being as high as ca. 0.09% P for a single determination, this technique can only be practical as an independent phosphorus analysis for high phosphorus cast irons. The precision on the28Al measurement is 5% relative for 0.2% Si and 2.5% above 1% Si.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos Publication Date 2006-10-11  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0134-0719; 2064-2857 ISBN Additional Links UA library record  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:116450 Serial 8528  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: