|
“Three-dimensional chemical characterization of complex silver halide microcrystals by scanning ion microprobe mass analysis”. Verlinden G, Janssens G, Gijbels R, van Espen P, Geuens I, Analytical chemistry 69, 3773 (1997). http://doi.org/10.1021/ac970010r
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Chemometrics (Mitac 3)
Impact Factor: 6.32
Times cited: 6
DOI: 10.1021/ac970010r
|
|
|
“Direct current glow discharge mass spectrometry for elemental characterization of polymers”. Schelles W, Van Grieken R, Analytical chemistry 69, 2931 (1997). http://doi.org/10.1021/AC970186T
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC970186T
|
|
|
“Direct current glow discharge mass spectrometric analysis of Macor ceramic using a secondary cathode”. Schelles W, Van Grieken R, Analytical chemistry 68, 3570 (1996). http://doi.org/10.1021/AC960441U
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC960441U
|
|
|
“Two-dimensional model of a direct current glow discharge : description of the argon metastable atoms, sputtered atoms and ions”. Bogaerts A, Gijbels R, Analytical chemistry 68, 2676 (1996). http://doi.org/10.1021/ac951206z
Abstract: A two-dimensional model is presented that describes the behavior of argon metastable atoms, copper atoms, and copper ions in an argon direct. current glow discharge, in the standard cell of the VG9000 glow discharge mass spectrometer for analyzing flat samples. The model is combined with a previously developed model for the electrons, argon ions, and atoms in the same cell to obtain an overall picture of the glow discharge, The results of the present model comprise the number densities of the described plasma species, the relative contributions of different production and loss processes for the argon metastable atoms, the thermalization profile of the sputtered copper atoms, the relative importance of the different ionization mechanisms for the copper atoms, the ionization degree of copper, the copper ion-to-argon ion density ratio, and the relative roles of copper ions, argon ions, and atoms in the sputtering process. All these quantities are calculated for a range of voltages and pressures, Moreover, since the sticking coefficient of copper atoms on solid surfaces is not well-known in the literature, the influence of this parameter on the results is briefly discussed.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 5.636
Times cited: 57
DOI: 10.1021/ac951206z
|
|
|
“Two-dimensional model of a direct current glow discharge: description of the electrons, argon ions and fast argon atoms”. Bogaerts A, Gijbels R, Goedheer WJ, Analytical chemistry 68, 2296 (1996). http://doi.org/10.1021/ac9510651
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 5.636
Times cited: 70
DOI: 10.1021/ac9510651
|
|
|
“Parameter evaluation for the analysis of oxide-based samples with radio ferquency glow discharge mass spectrometry”. de Gendt S, Van Grieken RE, Ohorodnik SK, Harrison WW, Analytical chemistry 67, 1026 (1995). http://doi.org/10.1021/AC00102A002
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00102A002
|
|
|
“Hydrodynamic model of matrix-assisted laser desorption mass spectrometry”. Vertes A, Irinyi G, Gijbels R, Analytical chemistry 65, 2389 (1993). http://doi.org/10.1021/ac00065a036
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 5.636
Times cited: 100
DOI: 10.1021/ac00065a036
|
|
|
“Influence of axial and radial diffusion processes on the analytical performance of a glow discharge cell”. van Straaten M, Gijbels R, Vertes A, Analytical chemistry 64, 1855 (1992). http://doi.org/10.1021/ac00041a021
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 5.636
Times cited: 43
DOI: 10.1021/ac00041a021
|
|
|
“X-ray spectrometry”. Török SB, Van Grieken RE, Analytical chemistry 64r, 180 (1992)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Expansion of laser-generated plumes near the plasma ignition threshold”. Balazs L, Gijbels R, Vertes A, Analytical chemistry 63, 314 (1991)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 5.636
Times cited: 71
|
|
|
“Discrimination between coprecipitated and adsorbed lead on individual calcite particles using laser microprobe mass analysis”. Wouters LC, Van Grieken RE, Linton RW, Bauer CF, Analytical chemistry 60, 2218 (1988). http://doi.org/10.1021/AC00171A011
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00171A011
|
|
|
“Enhancement effect in X-ray fluorescence analysis of environmental samples of medium thickness”. Van Dyck PM, Török SB, Van Grieken RE, Analytical chemistry 58, 1761 (1986). http://doi.org/10.1021/AC00121A036
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00121A036
|
|
|
“Absorption correction in electron probe x-ray microanalysis of thin samples”. Markowicz AA, Storms HM, Van Grieken RE, Analytical chemistry 58, 1282 (1986). http://doi.org/10.1021/AC00298A003
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00298A003
|
|
|
“Bremsstrahlung background in electron-probe X-ray-microanalysis of thin films”. Markowicz AA, Storms HM, Van Grieken RE, Analytical chemistry 57, 2885 (1985). http://doi.org/10.1021/AC00291A032
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00291A032
|
|
|
“Atomic number correction in electron probe X-ray microanalysis of curved samples and particles”. Markowicz AA, Van Grieken RE, Analytical chemistry 56, 2798 (1984). http://doi.org/10.1021/AC00278A036
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00278A036
|
|
|
“Composition dependence of Bremsstrahlung background in electron-probe x-ray microanalysis”. Markowicz AA, Van Grieken RE, Analytical chemistry 56, 2049 (1984). http://doi.org/10.1021/AC00276A016
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00276A016
|
|
|
“Embedded ion exchange beads as standards for laser microprobe mass analysis of biological specimens”. Verbueken AH, Van Grieken RE, Paulus GJ, De Bruijn WC, Analytical chemistry 56, 1362 (1984). http://doi.org/10.1021/AC00272A036
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00272A036
|
|
|
“Laser microprobe mass spectrometric identification of sulfur species in single micrometer-size particles”. Bruynseels FJ, Van Grieken RE, Analytical chemistry 56, 871 (1984). http://doi.org/10.1021/AC00270A004
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00270A004
|
|
|
“Absorption correction via scattered radiation in energy-dispersive X-ray fluorescence analysis for samples of variable composition and thickness”. Van Dyck PM, Van Grieken RE, Analytical chemistry 52, 1859 (1980). http://doi.org/10.1021/AC50062A020
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50062A020
|
|
|
“Characterization of a 2,2'-diaminodiethylamine-cellulose filter toward metal cation extraction”. Smits JA, Van Grieken RE, Analytical chemistry 52, 1479 (1980). http://doi.org/10.1021/AC50059A022
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50059A022
|
|
|
“Sub-part-per-billion determination of total dissolved selenium and selenite in environmental waters by X-ray fluorescence spectrometry”. Robberecht HJ, Van Grieken RE, Analytical chemistry 52, 449 (1980). http://doi.org/10.1021/AC50053A017
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50053A017
|
|
|
“Effective sample weight from scatter peaks in energy-dispersive x-ray fluorescence”. van Espen P, Van 't dack L, Adams F, Van Grieken R, Analytical chemistry 51, 961 (1979). http://doi.org/10.1021/AC50043A042
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1021/AC50043A042
|
|
|
“Chelex-100 ion-exchange filter membranes for preconcentration in x-ray-fluorescence analysis of water”. Van Grieken RE, Bresseleers CM, Vanderborght BM, Analytical chemistry 49, 1326 (1977). http://doi.org/10.1021/AC50017A011
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50017A011
|
|
|
“Absorption correction for X-ray-fluorescence analysis of aerosol loaded filters”. Adams FC, Van Grieken RE, Analytical chemistry 47, 1767 (1975). http://doi.org/10.1021/AC60361A040
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC60361A040
|
|
|
“Elemental trace analysis of small samples by proton-induced X-ray-emission”. Johansson TB, Van Grieken RE, Nelson JW, Winchester JW, Analytical chemistry 47, 855 (1975). http://doi.org/10.1021/AC60356A035
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC60356A035
|
|
|
“Chemical mapping of the degradation of geranium lake in paint cross sections by MALDI-MSI”. Alvarez-Martin A, Quanico J, Scovacricchi T, Avranovich Clerici E, Baggerman G, Janssens K, Analytical chemistry 95, 18215 (2023). http://doi.org/10.1021/ACS.ANALCHEM.3C03992
Abstract: Matrix assisted laser desorption ionization-mass spectrometry imaging (MALDI-MSI) has become a powerful method to extract spatially resolved chemical information in complex materials. This study provides the first use of MALDI-MSI to define spatial–temporal changes in oil paints. Due to the highly heterogeneous nature of oil paints, the sample preparation had to be optimized to prevent molecules from delocalizing. Here, we present a new protocol for the layer-specific analysis of oil paint cross sections achieving a lateral resolution of 10 μm and without losing ionization efficiency due to topographic effects. The efficacy of this method was investigated in oil paint samples containing a mixture of two historic organic pigments, geranium lake and lead white, a mixture often employed in the work of painter Vincent Van Gogh. This methodology not only allows for spatial visualization of the molecules responsible for the pink hue of the paint but also helps to elucidate the chemical changes behind the discoloration of paintings with this composition. The results demonstrate that this approach provides valuable molecular compositional information about the degradation pathways of pigments in specific paint layers and their interaction with the binding medium and other paint components and with light over time. Since a spatial correlation between molecular species and the visual pattern of the discoloration pattern can be made, we expect that mass spectrometry imaging will become highly relevant in future degradation studies of many more historical pigments and paints.
Keywords: A1 Journal article; Antwerp X-ray Imaging and Spectroscopy (AXIS); Ecosphere
Impact Factor: 7.4
DOI: 10.1021/ACS.ANALCHEM.3C03992
|
|
|
“Dual microfluidic sensor system for enriched electrochemical profiling and identification of illicit drugs on-site”. Steijlen ASM, Parrilla M, Van Echelpoel R, De Wael K, Analytical chemistry 96, 590 (2024). http://doi.org/10.1021/ACS.ANALCHEM.3C05039
Abstract: Electrochemical sensors have emerged as a new analytical tool for illicit drug detection to facilitate ultrafast and accurate identification of suspicious compounds on-site. Drugs of abuse can be identified using their unique voltammetric fingerprint at a given pH. Today, the right buffer solution is manually selected based on drug appearance, and in some cases, a consecutive analysis in two different pH solutions is required. In this work, we present a disposable microfluidic multichannel sensor system that automatically records fingerprints in two pH solutions (e.g., pH 5 and pH 12). This system has two advantages. It will overcome the manual selection of a buffer solution at the right pH, decrease analysis time, and minimize the risk of human errors. Second, the combination of two fingerprints, the superfingerprint, contains more detailed information about the samples, which enhances the selectivity of the analytical technique. First, real-time pH measurements proved that the sample can be brought to the desired pH within a minute. Subsequently, an electrochemical study on the microfluidic platform with 1 mM illicit drug standards of MDMA, cocaine, heroin, and methamphetamine showed that the characteristic voltammetric fingerprints and peak potentials are reproducible, also in the presence of common cutting agents. Finally, the microfluidic concept was validated with real confiscated samples, showing promising results for the user-friendly identification of drugs of abuse. In short, this paper presents a successful proof-of-concept study of a multichannel microfluidic sensor system to enrich the fingerprints of illicit drugs at pH 5 and pH 12, thus providing a low-cost, portable, and rapid identification system of illicit drugs with minimal user intervention.
Keywords: A1 Journal article; Engineering sciences. Technology; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 7.4
DOI: 10.1021/ACS.ANALCHEM.3C05039
|
|
|
“Photoelectrochemical behavior of phthalocyanine-sensitized TiO₂, in the presence of electron-shuttling mediators”. Khan SU, Trashin S, Beltran V, Korostei YS, Pelmus M, Gorun SM, Dubinina T V, Verbruggen SW, De Wael K, Analytical chemistry 94, 12723 (2022). http://doi.org/10.1021/ACS.ANALCHEM.2C02210
Abstract: Dye-sensitized TiO(2 )has found many applications for dye sensitized solar cells (DSSC), solar-to-chemical energy conversion, water/air purification systems, and (electro)chemical sensors. We report an electrochemical system for testing dye-sensitized materials that can be utilized in photoelectrochemical (PEC) sensors and energy conversion. Unlike related systems, the reported system does not require a direct electron transfer from semiconductors to electrodes. Rather, it relies on electron shuttling by redox mediators. A range of model photocatalytic materials were prepared using three different TiO2 materials (P25, P90, and PC500) and three sterically hindered phthalocyanines (Pcs) with electron-rich tert-butyl substituents (t-Bu4PcZn, t-Bu4PcAlCl, and t-Bu4PcH2). The materials were compared with previously developed TiO(2 )modified by electron-deficient, also sterically hindered fluorinated phthalocyanine F64PcZn, a singlet oxygen (O-1(2)) producer, as well as its metal-free derivative, F64PcH2. The PEC activity depended on the redox mediator, as well as the type of TiO2 and Pc. By comparing the responses of one-electron shuttles, such as K4Fe(CN)(4), and O-1(2)-reactive electron shuttles, such as phenol, it is possible to reveal the action mechanism of the supported photosensitizers, while the overall activity can be assessed using hydroquinone. t-Bu4PcAlCl showed significantly lower blank responses and higher specific responses toward chlorophenols compared to t-Bu4PcZn due to the electron-withdrawing effect of the Al3+ metal center. The combination of reactivity insights and the need for only microgram amounts of sensing materials renders the reported system advantageous for practical applications.
Keywords: A1 Journal article; Sustainable Energy, Air and Water Technology (DuEL); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 7.4
DOI: 10.1021/ACS.ANALCHEM.2C02210
|
|
|
“Direct sensing of superoxide and its relatives reactive oxygen and nitrogen species in phosphate buffers during cold atmospheric plasmas exposures”. Girard-Sahun F, Lefrancois P, Badets V, Arbault S, Clement F, Analytical Chemistry 94, 5555 (2022). http://doi.org/10.1021/ACS.ANALCHEM.1C04998
Abstract: This study aims at sensing in situ reactive oxygen and nitrogen species (RONS) and specifically superoxide anion (O-2(center dot-)) in aqueous buffer solutions exposed to cold atmospheric plasmas (CAPs). CAPs were generated by ionizing He gas shielded with variable N-2/O-2 mixtures. Thanks to ultramicroelectrodes protected against the high electric fields transported by the ionization waves of CAPs, the production of superoxide and several RONS was electrochemically directly detected in liquids during their plasma exposure. Complementarily, optical emissive spectroscopy (OES) was used to study the plasma phase composition and its correlation with the chemistry in the exposed liquid. The specific production of O-2(center dot-), a biologically reactive redox species, was analyzed by cyclic voltammetry (CV), in both alkaline (pH 11), where the species is fairly stable, and physiological (pH 7.4) conditions, where it is unstable. To understand its generation with respect to the plasma chemistry, we varied the shielding gas composition of CAPs to directly impact on the RONS composition at the plasma-liquid interface. We observed that the production and accumulation of RONS in liquids, including O(2)(center dot-)depends on the plasma composition, with N-2-based shieldings providing the highest superoxide concentrations (few 10s of micromolar at most) and of its derivatives (hundreds of micromolar). In situ spectroscopic and electrochemical analyses provide a high resolution kinetic and quantitative understanding of the interactions between CAPs and physiological solutions for biomedical applications.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 7.4
DOI: 10.1021/ACS.ANALCHEM.1C04998
|
|
|
“Correlation between the fluorination degree of perfluorinated zinc phthalocyanines, their singlet oxygen generation ability, and their photoelectrochemical response for phenol sensing”. Neven L, Barich H, Ching HYV, Khan SU, Colomier C, Patel HH, Gorun SM, Verbruggen S, Van Doorslaer S, De Wael K, Analytical chemistry 94, 5221 (2022). http://doi.org/10.1021/ACS.ANALCHEM.1C04357
Abstract: Electron-withdrawing perfluoroalkyl peripheral groups grafted on phthalocyanine (Pc) macrocycles improve their single-site isolation, solubility, and resistance to self-oxidation, all beneficial features for catalytic applications. A high degree of fluorination also enhances the reducibility of Pcs and could alter their singlet oxygen (1O2) photoproduction. The ethanol/toluene 20:80 vol % solvent mixture was found to dissolve perfluorinated FnPcZn complexes, n = 16, 52, and 64, and minimize the aggregation of the sterically unencumbered F16PcZn. The 1O2 production ability of FnPcZn complexes was examined using 9,10-dimethylanthracene (DMA) and 2,2,6,6-tetramethylpiperidine (TEMP) in combination with UV–vis and electron paramagnetic resonance (EPR) spectroscopy, respectively. While the photoreduction of F52PcZn and F64PcZn in the presence of redox-active TEMP lowered 1O2 production, DMA was a suitable 1O2 trap for ranking the complexes. The solution reactivity was complemented by solid-state studies via the construction of photoelectrochemical sensors based on TiO2-supported FnPcZn, FnPcZn|TiO2. Phenol photo-oxidation by 1O2, followed by its electrochemical reduction, defines a redox cycle, the 1O2 production having been found to depend on the value of n and structural features of the supported complexes. Consistent with solution studies, F52PcZn was found to be the most efficient 1O2 generator. The insights on reactivity testing and structural–activity relationships obtained may be useful for designing efficient and robust sensors and for other 1O2-related applications of FnPcZn.
Keywords: A1 Journal article; Organic synthesis (ORSY); Sustainable Energy, Air and Water Technology (DuEL); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 7.4
DOI: 10.1021/ACS.ANALCHEM.1C04357
|
|