|
“Magnetic- and particle-based techniques to investigate metal deposition on urban green”. Castanheiro A, Samson R, De Wael K, The science of the total environment 571, 594 (2016). http://doi.org/10.1016/J.SCITOTENV.2016.07.026
Abstract: Urban green works as a recorder of atmospheric PM. This paper reports on the utility of combining magnetic- and particle-based techniques to investigate PM leaf deposition as a bio-indicator of metal pollution. Ivy (Hedera helix) leaves were collected from five different land use classes, i.e. forest, rural, roadside, industrial, train. Leaf magnetic measurements were done in terms of saturation isothermal remanent magnetization (leaf SIRM), while ca. 40,000 leaf-deposited particles were analyzed through SEM/EDX to estimate the elemental composition. The influence of the different land use classes was registered both magnetically and in terms of metal content. Leaf area-normalized SIRM values ranged from 19.9 to 444.0 μA, in the following order forest < rural < roadside < industrial < train. Leaf SIRM showed to be significantly correlated (p < 0.01) with the content in Fe, Zn, and Pb, followed by Mn and Cd (p < 0.05), while no significant correlation was found with the metals Cr and Cu. Although presenting a similar metal content, roadside and train were magnetically very distinct. By exhibiting a very high content in Pb, and with an Fe content being comparable to the one observed at the forest and rural land uses, the industrial leaf-deposited particles showed to be mainly due to industrial activity. While SEM/EDX is a suitable approach for detailed particle analysis, leaf SIRM of ivy can be used as a rapid discriminatory tool for metal pollution. Their complementary use delivers further knowledge on land use classes reflecting different PM conditions and/or sources.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.9
Times cited: 17
DOI: 10.1016/J.SCITOTENV.2016.07.026
|
|
|
“Leaching of two fungicides in spent mushroom substrate amended soil : I influence of amendment rate, fungicide ageing and flow condition”. Álvarez-Martín A, Sanchez-Martin MJ, Ordax JM, Marin-Benito JM, Sonia Rodriguez-Cruz M, The science of the total environment 584, 828 (2017). http://doi.org/10.1016/J.SCITOTENV.2017.01.126
Abstract: A study has been conducted on the leaching of two fungicides, tebuconazole and cymoxanil, in a soil amended with spent mushroom substrate (SMS), with an evaluation of how different factors influence this process.The objective was based on the potential use of SMS as a biosorbent for immobilizing pesticides in vulnerable soils, and the need to know how it could affect the subsequent transport of these retained compounds. Breakthrough curves (BTCs) for C-14-fungicides, non-incubated and incubated over 30 days, were obtained in columns packed with an unamended soil (S), and this soil amended with SMS at rates of 5% (S + SMS5) and 50% (S + SMS50) under saturated and saturated-unsaturated flows. The highest leaching of tebuconazole (> 50% of the total C-14 added) was found in S when a saturated water flow was applied to the column, but the percentage of leached fungidde decreased when a saturated-unsaturated flow was applied in both SMS-amended soils. Also a significant decrease in teaching was observed for tebuconazole after incubation in the column, especially in S + SMS50 when both flows were applied. Furthermore, cymoxanil leaching was complete in S and S + SMS when a saturated flow was applied, and maximum peak concentrations were reached at 1 pore volume (PV), although BTCs showed peaks with lower concentrations in S + SMS. The amounts of cymoxanil retained only increased in S + SMS when a saturated-unsaturated flow was applied. A more relevant effect of SMS for reducing the leaching of fungidde was observed when cymoxanil was previously incubated in the column, although mineralization was enhanced in this case. These results are of interest for extending SMS application on the control of the leaching of fungicides with different physicochemical characteristics after different ageing times in the soil and water flow conditions applied. (C) 2017 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SCITOTENV.2017.01.126
|
|
|
“A new method to compensate for counting losses due to system dead time”. Karabidak SM, Čevik U, Kaya S, Nuclear instruments and methods in physics research : A: accelerators, spectrometers, detectors and associated equipment 603, 361 (2009). http://doi.org/10.1016/J.NIMA.2009.02.005
Abstract: Determination of count losses and pile-up pulse effects in quantitative and qualitative analysis became a vital step in various analyses. Therefore, compensating for counting losses is of importance. These counting losses are due to the pulse pile-up, paralyzable and non-paralyzable system dead time or a combination of these mechanisms. In this work, a new method is suggested for the correction of dead time losses resulting from the above mechanisms. For this purpose, a source code was developed. It was found that the peaking time was an important parameter over system dead time. The method suggested seems to be more effective even at high count rate. (C) 2009 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.NIMA.2009.02.005
|
|
|
“CAC-2010 : Twelfth international conference on chemometrics in analytical chemistry”. Buydens L, van Espen P, Rutan S, Analytica chimica acta 705, 1 (2011). http://doi.org/10.1016/J.ACA.2011.08.001
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.ACA.2011.08.001
|
|
|
“Characterization of radioactive particles from the Dounreay nuclear reprocessing facility”. Byrnes I, Lind OC, Hansen EL, Janssens K, Salbu B, Science Of The Total Environment 727, 138488 (2020). http://doi.org/10.1016/J.SCITOTENV.2020.138488
Abstract: Radioactive particles originating from nuclear fuel reprocessing at the United Kingdom Atomic Energy Authority's Dounreay Facility were inadvertently released to the environment in the late 1950s to 1970s and have subsequently been found on site grounds and local beaches. Previous assessments of risk associated with encountering a particle have been based on conservative assumptions related to particle composition and speciation. To reduce uncertainties associated with environmental impact assessments from Dounreay particles, further characterization is relevant. Results of particles available for this study showed variation between Dounreay Fast Reactor (DFR) and Materials Test Reactor (MTR) particles, reflecting differences in fuel design, release scenarios, and subsequent environmental influence. Analyses of DFR particles showed they are small (100-300 mu m) and contain spatially correlated U and Nb. Molybdenum, part of the DFR fuel, was identified at atomic concentrations below 1%. Based on SR-based micrometer-scale X-ray Absorption Near Edge Structure spectroscopy (mu-XANES), U may be present as U (IV), and, based on a measured Nb/U atom ratio of similar to 2, stoichiometric considerations are commensurable with the presence of UNb2O7. The MTR particles were larger (740-2000 mu m) and contained U and Al inhomogeneously distributed. Neodymium (Nd) was identified in atomic concentrations of around 1-2%, suggesting it was part of the fuel design. The presence of U(IV) in MTR particles, as indicated by mu-XANES analysis, may be related to oxidation of particle surfaces, as could be expected due to corrosion of UAlx fuel particles in air. High U-235/U-238 atom ratios in individual DFR (3.2 +/- 0.8) and MTR (2.6 +/- 0.4) particles reflected the presence of highly enriched uranium. The DFR particles featured lower Cs-137 activity levels (2.00-9.58 kBq/particle) than the MTR (43.2-641 kBq Cs-137/particle) particles. The activities of the dose contributing radionuclides Sr-90/Y-90 were proportional to Cs-137 (Sr-90/Cs-137 activity ratio approximate to 0.8) and particle activities were roughly proportional to the size. Based on direct beta measurements, gamma spectrometry, and the VARSKIN6 model, contact dose rates were calculated to be approximately 74 mGy/h for the highest activity MTR particle, in agreement with previously published estimates. (C) 2020 The Authors. Published by Elsevier B.V.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 9.8
Times cited: 1
DOI: 10.1016/J.SCITOTENV.2020.138488
|
|
|
“Electrodeposition of gold nanoparticles on boron doped diamond electrodes for the enhanced reduction of small organic molecules”. Bottari F, De Wael K, Journal of electroanalytical chemistry : an international journal devoted to all aspects of electrode kynetics, interfacial structure, properties of electrolytes, colloid and biological electrochemistry. 801, 521 (2017). http://doi.org/10.1016/J.JELECHEM.2017.07.053
Abstract: The performance of gold nanoparticles electrodeposited on boron doped diamond (BDD) electrodes was investigated in respect to the reduction of chloramphenicol (CAP), an antibiotic of the phenicols family. The chosen deposition protocol, three nucleation-growing pulses, shows a remarkable surface coverage, with an even distribution of average-sized gold particles (~ 50 nm), and it was proven capable of generating a three-fold increase in the CAP reduction current. A calibration plot for CAP detection was obtained in the micromolar range (535 μM) with good correlation coefficient (0.9959) and an improved sensitivity of 0.053 μA μM− 1 mm− 2 compared to the electrochemistry of CAP at a bare BDD electrode.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.012
Times cited: 4
DOI: 10.1016/J.JELECHEM.2017.07.053
|
|
|
“Confocal mu-XRF, mu-XAFS, and mu-XRD studies of sediment from a nuclear waste disposal natural analogue site and fractured granite following a radiotracer migration experiment”. Denecke MA, Janssens K, Brendebach B, de Nolf W, Falkenberg G, Rothe J, Simon R, Somogyi A, Vekemans B, Noseck U, AIP conference proceedings 882, 187 (2007)
Abstract: Combined mu-XRF, mu-XAFS, and mu-XRD investigations of a uranium-rich tertiary sediment, from a nuclear repository natural analogue site, and a fractured granite bore core section after a column tracer experiment using a Np(V) containing cocktail have been performed. Most mu-XRF/mu-XAFS measurements are recorded in a confocal geometry to provide added depth information. The U-rich sediment results show uranium to be present as a tetravalent phosphate and that U(IV) is associated with As(V). Arsenic present is either As(V) or As(0). The As(0) form thin coatings on the surface of pyrite nodules. A hypothesis for the mechanism of uranium immobilization is proposed, where arsenopyrite acted as reductant of ground water dissolved U(VI) leading to precipitation of less soluble U(IV) and thereby forming As(V). Results for the granite sample show the immobilized Np to be tetravalent and associated with facture material.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Voltammetric sensing using an array of modified SPCE coupled with machine learning strategies for the improved identification of opioids in presence of cutting agents”. Ortiz-Aguayo D, De Wael K, del Valle M, Journal Of Electroanalytical Chemistry 902, 115770 (2021). http://doi.org/10.1016/J.JELECHEM.2021.115770
Abstract: This work reports the use of modified screen-printed carbon electrodes (SPCEs) for the identification of three drugs of abuse and two habitual cutting agents, caffeine and paracetamol, combining voltammetric sensing and chemometrics. In order to achieve this goal, codeine, heroin and morphine were subjected to Square Wave Voltammetry (SWV) at pH 7, in order to elucidate their electrochemical fingerprints. The optimized SPCEs electrode array, which have a differentiated response for the three oxidizable compounds, was derived from Carbon, Prussian blue, Cobalt (II) phthalocyanine, Copper (II) oxide, Polypyrrole and Palladium nanoparticles ink-modified carbon electrodes. Finally, Principal Component Analysis (PCA) coupled with Silhouette parameter assessment was used to select the most suitable combination of sensors for identification of drugs of abuse in presence of cutting agents.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 3.012
DOI: 10.1016/J.JELECHEM.2021.115770
|
|
|
“Electrochemical identification of hazardous phenols and their complex mixtures in real samples using unmodified screen-printed electrodes”. Barich H, Cánovas R, De Wael K, Journal of electroanalytical chemistry : an international journal devoted to all aspects of electrode kynetics, interfacial structure, properties of electrolytes, colloid and biological electrochemistry. 904, 115878 (2022). http://doi.org/10.1016/J.JELECHEM.2021.115878
Abstract: The electrochemical behavior of some of the most relevant endocrine-disrupting phenols using unmodified carbon screen-printed electrodes (SPEs) is described for the first time. Experiments were made to assess the electrochemical behavior of phenol (PHOH), pentachlorophenol (PCP), 4-tert octylphenol (OP) and bisphenol A (BPA) and their determination in the most favorable conditions, using voltammetric methods such as cyclic voltammetry (CV), linear sweep voltammetry (LSV) and square wave voltammetry (SWV) in Britton Robinson (BR) buffer. Further, the usefulness of the electrochemical approach was validated with real samples from a local river and was compared to commercial phenols test kit, which is commonly used for on-site screening in industrial streams and wastewaters. Finally, the approach was compared with a lab-bench standard method using real samples, i.e., high-performance liquid chromatography with a photodiode array detector (HPLC-DAD).
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 4.5
DOI: 10.1016/J.JELECHEM.2021.115878
|
|
|
“Trace analysis of benzene, toluene, ethylbenzene and xylene isomers in environmental samples by low-pressure gas chromatography-ion trap mass spectrometry”. Joos PE, Godoi AFL, de Jong R, de Zeeuw J, Van Grieken R, Journal of chromatography: A: bibliography section 985, 191 (2003). http://doi.org/10.1016/S0021-9673(02)01843-5
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0021-9673(02)01843-5
|
|
|
“Application of low-pressure gas chromatography-io-trap mass spectrometry to the analysis of the eseential oil of Turnera diffusa (Ward.) Urb”. Godoi AFL, Vilegas W, Godoi RHM, Van Vaeck L, Van Grieken R, Journal of chromatography: A: bibliography section 1027, 127 (2004). http://doi.org/10.1016/J.CHROMA.2003.08.079
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.CHROMA.2003.08.079
|
|
|
“Fast chromatographic determination of polycyclic aromatic hydrocarbons in aerosol samples from sugar cane burning”. Godoi AFL, Ravindra K, Godoi RHM, Andrade SJ, Santiago-Silva M, Van Vaeck L, Van Grieken R, Journal of chromatography: A: bibliography section 1027, 49 (2004). http://doi.org/10.1016/J.CHROMA.2003.10.048
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.CHROMA.2003.10.048
|
|
|
“New insight into UO2F2 particulate structure by micro-Raman spectroscopy”. Stefaniak EA, Darchuk L, Sapundjiev D, Kips R, Aregbe Y, Van Grieken R, Journal of molecular structure 1040, 206 (2013). http://doi.org/10.1016/J.MOLSTRUC.2013.02.012
Abstract: Uranyl fluoride particles produced via hydrolysis of uranium hexafluoride have been deposited on different substrates: polished graphite disks, silver foil, stainless steel and gold-coated silicon wafer, and measured with micro-Raman spectroscopy (MRS). All three metallic substrates enhanced the Raman signal delivered by UO2F2 in comparison to graphite. The fundamental stretching of the UO band appeared at 867 cm−1 in case of the graphite substrate, while in case of the others it was shifted to lower frequencies (down to 839 cm−1). All applied metallic substrates showed the expected effect of Raman signal enhancement; however the gold layer appeared to be most effective. Application of new substrates provides more information on the molecular structure of uranyl fluoride precipitation, which is interesting for nuclear safeguards and nuclear environmental analysis.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.MOLSTRUC.2013.02.012
|
|
|
“Use of solid-phase microextraction for the detection of acetic acid by ion-trap gas chromatography-mass spectrometry and application to indoor levels in museums”. Godoi AFL, Van Vaeck L, Van Grieken R, Journal of chromatography: A: bibliography section 1067, 331 (2005). http://doi.org/10.1016/J.CHROMA.2004.12.054
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.CHROMA.2004.12.054
|
|
|
“Controlling the mixed potential of polyelectrolyte-coated platinum electrodes for the potentiometric detection of hydrogen peroxide”. Baez JF, Compton M, Chahrati S, Cánovas R, Blondeau P, Andrade FJ, Analytica Chimica Acta 1097, 204 (2020). http://doi.org/10.1016/J.ACA.2019.11.018
Abstract: The use of a Pt electrode coated with a layer of Nafion has been described in previous works as an attractive way to perform the potentiometric detection of hydrogen peroxide. Despite of the attractive features of this approach, the nature of the non-Nernstian response of this system was not properly addressed. In this work, using a mixed potential model, the open circuit potential of the Pt electrode is shown to be under kinetic control of the oxygen reduction reaction (ORR). It is proposed that hydrogen peroxide acts as an oxygenated species that blocks free sites on the Pt surface, interfering with the ORR. Therefore, the effect of the polyelectrolyte coating can be understood in terms of the modulation of the factors that affects the kinetics of the ORR, such as an increase of the H+ concentration, minimization of the effect of the spectator species, etc. Because of the complexity and the lack of models that accurately describe systems with practical applications, this work is not intended to provide a mechanistic but rather a phenomenological view on problem. A general framework to understand the factors that affect the potentiometric response is provided. Experimental evidence showing that the use of polyelectrolyte coatings are a powerful way to control the mixed potential open new ways for the development of robust and simple potentiometric sensors.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.2
DOI: 10.1016/J.ACA.2019.11.018
|
|
|
“Low-pressure gas chromatography-ion trap mass spectrometry for the fast determination of polycyclic aromatic hydrocarbons in air samples”. Ravindra K, Godoi AFL, Bencs L, Van Grieken R, Journal of chromatography: A: bibliography section 1114, 278 (2006). http://doi.org/10.1016/J.CHROMA.2006.03.025
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.CHROMA.2006.03.025
|
|
|
“Fast analysis of decabrominated diphenyl ether using low-pressure gas chromatography.electron-capture negative ionization mass spectrometry”. Dirtu AC, Ravindra K, Roosens L, Van Grieken R, Neels H, Blust R, Covaci A, Journal of chromatography : A 1186, 295 (2008). http://doi.org/10.1016/J.CHROMA.2007.07.034
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre
DOI: 10.1016/J.CHROMA.2007.07.034
|
|
|
“Behavior of semi-volatile particles under a laser and electron beam: influence on the quality of analytical results”. Worobiec A, Potgieter-Vermaak S, Darchuk L, Vishnyakov V, Potgieter H, Van Grieken R, AIP conference proceedings 1267, 523 (2010). http://doi.org/10.1063/1.3482653
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1063/1.3482653
|
|
|
“Composition of aerosols from the shelter of the Chernobyl power plant”. Darchuk L, Worobiec A, Khan V, Krasnov V, Van Grieken R, AIP conference proceedings 1267, 512 (2010). http://doi.org/10.1063/1.3482646
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1063/1.3482646
|
|
|
“Kinetic properties and heme pocket structure of two domains of the polymeric hemoglobin of Artemia in comparison with the native molecule”. Borhani AH, Berghmans H, Trashin S, De Wael K, Fago A, Moens L, Habibi-Rezaei M, Dewilde S, Biochimica et biophysica acta : proteins and proteomics 1854, 1307 (2015). http://doi.org/10.1016/J.BBAPAP.2015.05.007
Abstract: In this project, we studied some physicochemical properties of two different globin domains of the polymeric hemoglobin of the brine shrimp Artemia salina and compared them with those of the native molecule. Two domains (AsHbC1D1 and AsHbC1D5) were cloned and expressed in BL21(DE3)pLysS strain of Escherichiacoli. The recombinant proteins as well as the native hemoglobin (AfHb) were purified from bacteria and frozen Artemia, respectively by standard chromatographic methods and assessed by SDS-PAGE. The heme environment of these proteins was studied by optical spectroscopy and ligand-binding kinetics (e.g. CO association and O2 binding affinity) were measured for the two recombinant proteins and the native hemoglobin. This indicates that the CO association rate for AsHbC1D1 is higher than that of AsHbC1D5 and AfHb, while the calculated P50 value for AsHbC1D1 is lower than that of AsHbC1D5 and AfHb. The geminate and bimolecular rebinding parameters indicate a significant difference between both domains. Moreover, EPR results showed that the heme pocket in AfHb is in a more closed conformation than the heme pocket in myoglobin. Finally, the reduction potential of − 0.13 V versus the standard hydrogen electrode was determined for AfHb by direct electrochemical measurements. It is about 0.06 V higher than the potential of the single domain AsHbC1D5. This work shows that each domain in the hemoglobin of Artemia has different characteristics of ligand binding.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.773
DOI: 10.1016/J.BBAPAP.2015.05.007
|
|
|
“The identification of chromophores in ancient glass by the use of UV-VIS-NIR spectroscopy”. Meulebroeck W, Baert K, Wouters H, Cosyns P, Ceglia A, Cagno S, Janssens K, Nys K, Terryn H, Thienpont H, Proceedings of the Society of Photo-optical Instrumentation Engineers 7726, 77260d (2010). http://doi.org/10.1117/12.853666
Abstract: In this publication optical spectroscopy is considered to be a supplementary technique to study ancient colored glass. It results from a systematic study of the UV-VIS-NIR transmission spectra of intentionally colored glass fragments from various archaeological and historical sites and dated from the Roman period to the 21th century AD. The main goal consists of defining optical sensing parameters for this type of material. The considered colorants are iron, cobalt, manganese, copper and chromium. It is proved that many cases exist where optical spectroscopy can be seen as a straightforward, non-destructive, low-cost and in-situ applicable technique in identifying authentic material or to obtain information about the origin of the material. Possible sensing parameters are defined as the absence/presence of absorption bands characteristic for a specific coloring metal oxide and the spectral position of these bands. These parameters could reveal information about the applied furnace conditions and/or to the composition of the glass matrix. It is shown that the cobalt absorption band situated around 535 nm for soda rich glasses (Roman and industrial times) is shifted towards 526 nm for potash rich glasses (medieval and post-medieval times).
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 10
DOI: 10.1117/12.853666
|
|
|
“Tangible versus intangible in e-learning on cultural heritage : from online learning to on-site study of historic sites”. Lobovikov-Katz A, Moropoulou A, Konstanti A, Ortiz Calderon P, Van Grieken R, Worth S, Cassar JA, De Angelis R, Biscontin G, Izzo FC, Lecture notes in computer science
T2 –, 5th EuroMed International Conference, NOV 03-08, 2014, Amathus, CYPRUS 8740, 819 (2014). http://doi.org/10.1007/978-3-319-13695-0_84
Abstract: The revolutionary development in digital theory and technology calls for non-trivial decisions in bridging between the virtual and real worlds. The field of conservation of cultural heritage thus provides various challenges, especially with regards to learning, study and investigation of tangible heritage through applications of intangible ICT technologies. This paper examines the interaction between e-learning, and the actual on-site learning and study of historic buildings and sites, with an emphasis on their visual characteristics. In this context, the paper presents some aspects of application of a methodology which allows basic documentation, monitoring and primary analysis of data on cultural (built) heritage sites by general public through educational process enabled by an e-learning platform.
Keywords: P1 Proceeding; Documentation and information; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/978-3-319-13695-0_84
|
|