|
“Comparison of four mobile, non‐invasive diagnostic techniques for differentiating glass types in historical leaded windows : MA‐XRF , UV–Vis–NIR, Raman spectroscopy and IRT”. Cagno S, van der Snickt G, Legrand S, Caen J, Patin M, Meulebroeck W, Dirkx Y, Hillen M, Steenackers G, Rousaki A, Vandenabeele P, Janssens K, X-Ray Spectrometry , xrs.3185 (2020). http://doi.org/10.1002/XRS.3185
Abstract: This paper critically compares the performance of four non-invasive techniques that match the accuracy, flexibility, time-efficiency, and transportability required for in situ characterization of leaded glass windows: macroscopic X-ray fluorescence imaging (MA-XRF), UV-Vis-NIR, Raman spectroscopy, and infrared thermography (IRT). In order to compare the techniques on equal grounds, all techniques were tested independently of each other by separate research groups on the same historical leaded window tentatively dated to the 17th century, without prior knowledge. The aim was to assess the ability of these techniques to document the conservation history of the window by classifying and grouping the colorless glass panes, based on differences in composition. IRT, MA-XRF and UV-Vis-NIR spectroscopy positively distinguished at least two glass groups, with MA-XRF providing the most detailed chemical information. In particular, based on the ratio between the network modifier (K) and network stabilizer (Ca) and on the level of colorants and decolorizers (Fe, Mn, As), the number of plausible glass families could be strongly reduced. In addition, UV-Vis-NIR detected cobalt at ppm level and gave more specific information on the chromophore Fe2+/Fe(3+)ratio. Raman spectroscopy was hampered by fluorescence caused by the metal ions of the decolorizer in most of the panes, but nevertheless identified one group as HLLA.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
Impact Factor: 1.2
DOI: 10.1002/XRS.3185
|
|
|
“X-ray spectrometry applied for characterization of bricks of Brazilian historical sites”. Asfora VK, Bueno CC, de Barros VM, Khoury H, Van Grieken R, X-Ray Spectrometry , 1 (2020). http://doi.org/10.1002/XRS.3194
Abstract: This paper presents the results of X-ray fluorescence (XRF) analysis of bricks sampled from historical places in Pernambuco, a state in the northeastern region of Brazil. In this study, twenty bricks found in historical sites were analyzed. Two bricks made in the 17th century, presumably used as ballast in ships coming from Holland, five locally manufactured bricks: one from 18th century, three from 19th century, and one from 20th century, and thirteen bricks collected from a recent Archeological investigation of Alto da Se, in the town of Olinda. Qualitative determination of the chemical elements present in the samples was undertaken using a self-assembled portable XRF system based on a compact X-ray tube and a thermoelectrically cooled Si-PIN photodiode system, both commercially available. X-ray diffraction analysis was also carried out to assess the crystalline mineral phases present in the bricks. The results showed that quartz (SiO2) is the major mineral content in all bricks. Although less expressive in the XRD patterns, mineral phases of illite, kaolinite, anorthite, and rutile are also identified. The trace element distribution patterns of the bricks, determined by the XRF technique, is dominated by Fe and, in decreasing order, by K, Ti, Ca, Mn, Zr, Rb, Sr, Cr, and Y with slight differences among them. Analyses of the chemical compositional features of the bricks, evaluated by principal component analysis of the XRF datasets, allowed the samples to be grouped into five clusters with similar chemical composition. These cluster groups were able to identify both age and manufacturing sites. Dutch bricks prepared with different geological clays compositions were defined.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.2
DOI: 10.1002/XRS.3194
|
|
|
“Folding of aerosol loaded filters during X-ray fluorescence analysis”. Van Grieken RE, Adams FC, X-ray spectrometry 5, 61 (1976). http://doi.org/10.1002/XRS.1300050204
Abstract: Folding aerosol loaded filters in two with the loaded side inwards during the X-ray analysis not only reduces possible filter heterogeneity effects and improves sample protection, but also increases the sensitivity and renders filter paper absorption corrections simple and more accurate in many instances. It is shown that folding an aerosol loaded Whatman filter paper during Kα X-rays counting leads to an increased sensitivity for all elements up from calcium, scandium or titanium (depending on the sensitivity definition and on the aerosol load) and for all elements up from phosphorus, sulphur or chlorine in the case of the Nuclepore filter. Although the absorption by the filter, into which the aerosol penetrates to some extent, is always more important in the sandwich than in the usual geometry, the dependence of the absorption correction on the usually unknown average deposition depth is less pronounced. Assuming all the aerosol material to be collected at the very surface of the filter and hence being present in the centre of the sandwich to be analysed, leads to an extremely simple filter paper absorption correction which is less prone to uncertainties than more sophisticated corrections in the usual geometry requiring additional measurements. This is the case for all elements up from potassium on Whatman filters and up from phosphorus on Nuclepore filters.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300050204
|
|
|
“Trace analysis of estuarine brown algae by energy-dispersive X-ray fluorescence”. Sauter L, Van der Ben D, Van Grieken R, X-ray spectrometry 8, 159 (1979). http://doi.org/10.1002/XRS.1300080405
Abstract: Brown algae, which are good indicators for estuarine metal pollution, can advantageously be analysed by energy-dispersive X-ray fluorescence. The use of thin film samples and samples of intermediate thickness has several advantages over the conventional thick pellet procedure. A quite homogeneous thin target is prepared by suspending 15 mg of dried and ground seaweed powder in bi-distilled water and evaporating the slurry on a 10 cm2 Mylar foil held in a Teflon ring. The effective sample weight in the beam is calculated by a procedure based on the scatter peaks in the spectrum. Sensitivities are typically in the 215 ppm range. The coefficient of variation per analysis averaged over ten elements amounts to 10%. The natural concentration variation in seaweed specimens at one location is 13%. Samples from locations in the more polluted western Scheldt estuary yield significantly higher values for several elements, relative to the eastern Scheldt sites. Possible trace element variations between the top and base of plants, and between different seaweed specimens and sampling seasons, are discussed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300080405
|
|
|
“Automatic absorption correction in x-ray fluorescence analysis of intermediate thickness samples using a dual external reference signal”. Van Dyck P, Markowicz A, Van Grieken R, X-ray spectrometry 9, 70 (1980). http://doi.org/10.1002/XRS.1300090209
Abstract: A method has been investigated which allows calculations from the X-ray fluorescence spectra of the absorption coefficients at any energy for any sample, without any additional measurement. Use is made of the ratio of the characteristic X-ray signals from a Zr wire positioned in front of the sample and from a Pd foil placed behind the sample, both in a fixed geometry. From the experimentally measured absorption coefficient at the Pd L energy (2.9 keV), the coefficients for higher energies are calculated. By the use of an iterative computer routine in which corrections for the enhancement of the Pd foil by the sample are also included, an accuracy of 2% or better on the absorption coefficient determination can be reached for homogenous samples in one measurement. Grain-size and heterogeneity effects induce inaccuracies on the absorption coefficient determinations which might well reach 20% for particulate samples like intermediate thickness deposits of geological materials. This approach thus has the same limitations as the classical transmission method for such heterogeneous samples.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300090209
|
|
|
“Radiometric diameter concept and exact intensities for spherical particles in x-ray fluorescence analysis”. Markowicz A, Van Dyck P, Van Grieken R, X-ray spectrometry 9, 52 (1980). http://doi.org/10.1002/XRS.1300090205
Abstract: In X-ray fluorescence analysis the concept of radiometric diameter, d, is often introduced in considerations of the fluorescent intensity from a particulate sample. It represents the mean geometric path of the X-rays through one particle and is usually simply taken to be equal to the volume-to-area ratio of the particle. The effective radiometric path is, however, itself dependent on geometry and absorption effects. Rigorous calculations of the fluorescent intensity from a particle in the π and π/2 geometries were carried out to evaluate the errors involved. It appears that, for π geometry, the discrepancy between these exact results and the intensity calculated via the use of d does not exceed 5.2%. For the π/2 geometry, the errors are much larger and can amount to 50% in realistic cases of X-ray fluorescence analysis. These conclusions are also applicable to monolayers. The effective radiometric diameter approaches d only when absorption effects become negligible, but is smaller in other cases.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300090205
|
|
|
“Automated matrix-correction of line ratios in energy-dispersive x-ray fluorescence spectrum deconvolution”. Van Dyck P, Van Grieken R, X-ray spectrometry 12, 111 (1983). http://doi.org/10.1002/XRS.1300120306
Abstract: Most computer XRF-spectrum deconvolution routines make use of fixed intensity ratios for the lines from one element. The magnitude of the error that fixed ratios imply has been quantitatively evaluated for samples with a varible thickness or matrix. A procedure for routinely adapting the line ratios according to the matrix effect in every sample (by making use of the matrix information present in the scatter peaks) enhances the accuracy of the spectrum evaluation.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300120306
|
|
|
“Heterogeneity effects in direct X-ray fluorescence analysis of hair”. Török S, Van Dyck P, Van Grieken R, X-ray spectrometry 13, 27 (1984). http://doi.org/10.1002/XRS.1300130106
Abstract: The methodology of direct hair analysis by energy-dispersive x-ray fluorescence was studied. The effect on the XRF result of having a non-homogeneous radial distribution of the analyte in a single hair strand and the macroscopic effects in a bundle of hairs were calculated to evaluate possible systematic errors. The detection limits were mapped as a function of the target thickness and surface fraction. It appeared that a 10 mg cm−2 sample thickness, i. e. a target with about four layers of hair strands, is recommended. The standard deviation of this simple direct analytical method is 619% for some important elements. Discrepancies with neutron activation analysis had a mean value of around 15%. About twelve elements can be determined simultaneously on a routine basis.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300130106
|
|
|
“Influence of sample thickness, excitation energy and geometry on particle size effects in XRF”. Van Dyck P, Markowicz A, Van Grieken R, X-ray spectrometry 14, 183 (1985). http://doi.org/10.1002/XRS.1300140409
Abstract: Expressions are presented for calculating the matrix effect and the pure particle size effect in the XRF analysis of particulate samples with a discrete particle size. The equations are based on the absorption-weighted radiometric diameter concept. Two excitationdetection geometries are considered, with the angles between the sample plane and both the incident and emerging radiation being either 90° (π geometry) or 45° (π/2 geometry). Calculations were made for different sample loadings and exciting radiation energies. The influence of these parameters on the matrix and pure particle size effects is shown. From the results, it is possible to predict the performances of alternative experimental correction procedures for the particle size effect, involving dual measurements at different excitation energies or in different excitationdetection geometries.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300140409
|
|
|
“Determination of barium, lanthanum, cerium and neodymium in lateritic materials by various energy-dispersive X-ray fluorescence techniques and neutron activation analysis”. Labrecque JJ, Beusen JM, Van Grieken RE, X-ray spectrometry 15, 13 (1986). http://doi.org/10.1002/XRS.1300150105
Abstract: A comparison of four methods for the determination of barium, lanthanum, cerium and neodymium in lateritic materials from Brazil is presented. Three of the methods were based on x-ray fluorescence (XRF) spectroscopy: two by radioisotope excitation (Co-57 and Am-241) and one by secondary target XRF (a molybdenum target with a tungsten anode). The other method was based on neutron activation analysis employing both a Ge(Li) coaxial detector and a high-purity germanium detector. The results from these four methods were similar for lanthanum, cerium and neodymium, but for barium at low concentrations (<500 ppm) the neutron activation and the secondary target XRF methods were not suitable. Data on the precision and accuracy of these methods using a series of standard reference rocks are given. The advantages and limitations of each of these methods with respect to the analysis of lateritic materials are discussed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150105
|
|
|
“Evaluation of an equation for bremsstrahlung background in electron-probe X-ray microanalysis of composite samples”. Markowicz A, Storms H, Van Grieken R, X-ray spectrometry 15, 131 (1986). http://doi.org/10.1002/XRS.1300150211
Abstract: A new equation for predicting the generated bremsstrahlung background intensity in electron-probe x-ray microanalysis has been verified experimentally. This equation is applicable to all bulk composite specimens and reduces to Kramers' equation for pure elements only. The experimental verification has been carried out for Al2O3, Fe2O3 and ZrO2 with radiation energies from 4.2 to 14.8 keV. The predicted bremsstrahlung intensities are in good agreement with the experimental data.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150211
|
|
|
“Heterogeneity effects in direct XRF analysis of traces of heavy metals preconcentrated on polyurethane foam sorbents”. Török S, Braun T, Van Dyck P, Van Grieken R, X-ray spectrometry 15, 7 (1986). http://doi.org/10.1002/XRS.1300150104
Abstract: Trace amounts of heavy metals were preconcentrated on discs of polyurethane (PU) foam loaded with ammonium diethyldithiocarbamate (DDTC), to increase the sensitivity of XRF. Since the diameter of the cavities in the open-cell PU foams reaches 30300 μm, considerable heterogeneity effects might occur, which could reduce the accuracy of the method. The possible systematic error introduced by considering the sample to be homogeneous is calculated using the Berry et al. model. The calculations show that the underestimation of the absorption correction factor when considering the sample as being homogeneous is less than 2% for high-Z elements when the sample thickness is at least 2 mm. The detection limits are also around the minima for this thickness.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150104
|
|
|
“Monte Carlo simulation of backscattered peaks in secondary target energy-dispersive X-ray spectra”. Van Dyck P, Török S, Van Grieken R, X-ray spectrometry 15, 231 (1986). http://doi.org/10.1002/XRS.1300150403
Abstract: A Monte Carlo simulation has been developed to describe the incoherent and coherent scatter processes for the complex geometry of a secondary target energy-dispersive x-ray fluorescence system. Photons are followed from the x-ray tube anode until the detection of scattered secondary target photons in the active Si layer of the detector. The program quantitatively shows the broadening of the incoherent scatter peak with increasing atomic number, and it models the incoherent peak shape adequately. The incoherent-to-coherent scatter intensity ratios obtained differ by 1030% from the theoretical values, while their dependence on the sample atomic number corresponds to that expected from theory.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150403
|
|
|
“A simple absorption correction for electron probe X-ray microanalysis of bulk samples”. Markowicz A, Storms H, Van Grieken R, X-ray spectrometry 15, 115 (1986). http://doi.org/10.1002/XRS.1300150209
Abstract: A simple procedure is proposed for the calculation of the absorption correction factor in electron-probe x-ray microanalysis. It is based on the concept of an effective depth of x-ray production, assuming a rectangular depth distribution function for x-ray generation. This effective x-ray production depth is expressed as a fraction of the x-ray excitation depth given by Whelan's expression. Adequate values for this fraction are presented. Two versions are considered. In the first the effective x-ray production is a function of both the characteristic x-ray energy and the atomic numbers of the matrix elements, whereas in the second one, which is indicated for routine use, the energy dependence is neglected. Calculations pointed to satisfactory results, even for low x-ray energies and high overvoltages.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150209
|
|
|
“Evaluation of the ArmstrongBuseck correction for automated electron probe X-ray microanalysis of particles”. Storms HM, Janssens KH, Török SB, Van Grieken RE, X-ray spectrometry 18, 45 (1989). http://doi.org/10.1002/XRS.1300180203
Abstract: The ArmstrongBuseck correction for absorption effects in electron probe x-ray microanalysis of particles considers seven specific particle shapes, and for these geometries exact correction equations are used. This procedure implies that the analyst has to associate the particle to be analysed with a certain particle type; an arbitrary relative thickness is sometimes assumed. A theoretical study was made of this absorption correction as a function of the particle composition, type and thickness for micrometre-sized particles. It appears that a correct choice of the particle type is critical. However, when the analytical results are normalized to 100%, the differences between the models are much less pronounced, and it is justified to assume a spherical model in all cases.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300180203
|
|
|
“Theoretical evaluation of the effective alpha and De Jongh approaches in X-ray fluorescence analysis of geological materials in borax glass beads”. Muia LM, Van Grieken R, X-ray spectrometry 18, 259 (1989). http://doi.org/10.1002/XRS.1300180604
Abstract: An evaluation of the accuracy and suitability of the LachanceTraill algorithm using effective α-coefficients, and the De Jongh α approach for x-ray fluorescence analysis of borax glass beads prepared from geological material was performed. By using theoretical α-coefficients obtained from the same standard and calculated elemental intensities, the two algorithms were compared under identical conditions. When only the monitor standard is used, the LachanceTrail1 approach is found to be inferior to the De Jongh basic α method. If multi-standard calibration is performed for both approaches, the accuracies are almost identical and no significant difference is found in the results. The LachanceTraill algorithm has the advantage of being easier to implement on a minicomputer and, when used without standards, it is found to give results within a few percent of the true values, which is a useful indicator in the choice of appropriate standards for more accurate analytical work.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300180604
|
|
|
“Determination of sample thickness via scattered radiation in X-ray fluorescence spectrometry with filtered continuum excitation”. Araujo MF, van Espen P, Van Grieken R, X-ray spectrometry 19, 29 (1990). http://doi.org/10.1002/XRS.1300190107
Abstract: A semi-empirical approach is described for determining the mass per unit area of a sample being analysed. The method can be used to estimate the concentration of minor and trace elements in matrices containing a substantial amount of light elements. The procedure utilizes the coherently and incoherently scattered radiation induced in the sample by the filtered continuum radiation of a rhodium x-ray tube. The relationship between the intensity of the scattered radiation per unit mass and the average atomic number of the sample is established via calibration graphs, which can be applied for different x-ray tube voltages and for different primary beam filters. The overall procedure was validated by the analysis of several geological standards, deposited as thin slurries of unknown thickness either on Mylar foil or on Nuclepore filters.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300190107
|
|
|
“Use of theoretical accurate binary influence coefficients with Tertian's equation in X-ray fluorescence analysis of silicate rocks in borax glass beads”. Muia LM, Van Grieken R, X-ray spectrometry 19, 141 (1990). http://doi.org/10.1002/XRS.1300190311
Abstract: A study of the suitability of the Tertian algorithm using new accurate binary influence coefficients and a comparison standard for x-ray fluorescence analysis of geological materials prepared as borax glass beads was performed. The algorithm was found to give satisfactory results for the analysis of four major components in geological materials. Even in the worst case, when there is a factor of 20 difference in the concentration in the specimen and a comparison standard, the algorithm gives results which differ from the true results by a factor of about 2. This makes the algorithm attractive as a diagnostic tool in analyses of unknown specimens and in the identification of appropriate standards. The binary coefficients are easily calculated so that the algorithm can be implemented on a minicomputer.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300190311
|
|
|
“Current trends in the literature on X-ray emission spectrometry”. Van Grieken R, Markowicz A, Veny P, X-ray spectrometry 20, 271 (1991). http://doi.org/10.1002/XRS.1300200605
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300200605
|
|
|
“Energy-dispersive X-ray fluorescence analysis of geological materials in borax beads using Tertian's binary coefficient approach combined with internal standard addition”. Muia LM, Van Grieken R, X-ray spectrometry 20, 179 (1991)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Monte Carlo simulation of conventional and synchrotron energy-dispersive X-ray spectrometers”. Janssens K, Vincze L, van Espen P, Adams F, X-ray spectrometry 22, 234 (1993). http://doi.org/10.1002/XRS.1300220412
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300220412
|
|
|
“EDXRS study of aerosol composition variations in air masses crossing the North Sea”. Injuk J, van Malderen H, Van Grieken R, Swietlicki E, Knox JM, Schofield R, X-ray spectrometry 22, 220 (1993). http://doi.org/10.1002/XRS.1300220410
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300220410
|
|
|
“M\alpha/L\alpha intensity ratios for Ta, W, Pt, Au, Pb and Bi for electron energies in the 11-40 keV range”. Trincavelli J, Montoro S, van Espen P, Van Grieken R, X-ray spectrometry 22, 372 (1993). http://doi.org/10.1002/XRS.1300220510
Abstract: Both energy- and wavelength-dispersive systems were used to obtain Malpha/Lalpha intensity ratios for Ta, W, Pt, Au, Pb and Bi at various overvoltages. A table of these ratios corrected for matrix absorption and detector efficiency is presented, in addition to an interpolatory function of Malpha/Lalpha generated ratios vs. overvoltage, for each element. In addition, three different ZAF correction models were used to predict both detected and generated ratios. Finally, experimental Mbeta/Malpha ratios measured at different overvoltages are presented for the six elements considered.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300220510
|
|
|
“Analysis of X-ray spectra by iterative least squares (AXIL): new developments”. Vekemans B, Janssens K, Vincze L, Adams F, van Espen P, X-ray spectrometry 23, 278 (1994). http://doi.org/10.1002/XRS.1300230609
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300230609
|
|
|
“Automated segmentation of μ-XRF image sets”. Vekemans B, Janssens K, Vincze L, Aerts A, Adams F, Hertogen J, X-ray spectrometry 26, 333 (1997)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
|
|
|
“Energy-dispersive X-ray fluorescence in geochemical mapping”. Civici N, Van Grieken R, X-ray spectrometry 26, 147 (1997). http://doi.org/10.1002/(SICI)1097-4539(199707)26:4<147::AID-XRS193>3.0.CO;2-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/(SICI)1097-4539(199707)26:4<147::AID-XRS193>3.0.CO;2-X
|
|
|
“Application of auxiliary signals in X-ray fluorescence and electron microprobe analysis for density evaluation”. Kuczumov A, Vekemans B, Schalm O, Vincze L, Dorriné, W, Gysels K, Van Grieken R, X-ray spectrometry 28, 282 (1999). http://doi.org/10.1002/(SICI)1097-4539(199907/08)28:4<282::AID-XRS352>3.0.CO;2-H
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/(SICI)1097-4539(199907/08)28:4<282::AID-XRS352>3.0.CO;2-H
|
|
|
“Progress in laboratory grazing emission X-ray fluorescence spectrometry”. Claes M, de Bokx P, Van Grieken R, X-ray spectrometry 28, 224 (1999). http://doi.org/10.1002/(SICI)1097-4539(199907/08)28:4<224::AID-XRS337>3.3.CO;2-W
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/(SICI)1097-4539(199907/08)28:4<224::AID-XRS337>3.3.CO;2-W
|
|
|
“Use of microscopic XRF for non-destructive analysis in art an archaeometry”. Janssens K, Vittiglio G, Deraedt I, Aerts A, Vekemans B, Vincze L, Wei F, de Ryck I, Schalm O, Adams F, Rindby A, Knöchel A, Simionovici AS, Snigirev A, X-ray spectrometry 29, 73 (2000). http://doi.org/10.1002/(SICI)1097-4539(200001/02)29:1<73::AID-XRS416>3.3.CO;2-D
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
DOI: 10.1002/(SICI)1097-4539(200001/02)29:1<73::AID-XRS416>3.3.CO;2-D
|
|
|
“Component selection for a compact micro-XRF spectrometer”. Bichlmeier S, Janssens K, Heckel J, Gibson D, Hoffmann P, Ortner HM, X-ray spectrometry 30, 8 (2001). http://doi.org/10.1002/XRS.457
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 33
DOI: 10.1002/XRS.457
|
|