Kara De Maeijer, P.; Craeye, B.; Snellings, R.; Kazemi-Kamyab, H.; Loots, M.; Janssens, K.; Nuyts, G. |
|
|
Title |
Effect of ultra-fine fly ash on concrete performance and durability |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Construction And Building Materials |
Abbreviated Journal |
Constr Build Mater |
|
|
Volume |
263 |
Issue |
|
Pages |
120493-13 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Energy and Materials in Infrastructure and Buildings (EMIB) |
|
|
Abstract |
In the present study ultra-fine fly ash as a novel by-product obtained by a dry and closed separation process was investigated as cement replacement in concrete. The impact of ultra-fine fly ash on material properties was investigated following an upscaling as an approach considering paste, mortar and concrete properties. Two types of cement, Portland cement (CEMI) and slag cement (CEMIII), two types of ultra-fly ashes, one with particle size d90< 9.3lm (FA1) and second with d90< 4.6lm (FA2) were used.At paste- and mortar- level, cement was replaced at 0%, 15%, 25%, 35% and 50% with FA1 and FA2. At concrete- level, cement was replaced at 0%, 15% and 25% with different ratios of FA1 and FA2. The results at paste- and mortar- level showed that an increased fineness of the fly ash (FA2) contributes to better workability of the mix. For CEMI, the compressive strength of concrete with FA2 at 25% cement replacement was already equal to the reference 0% replacement concrete at the age of 28 days. For CEMIII, the compressive strength of concrete mix with FA1 with 15% and FA2 with 25% cement replacements reached the reference concrete value at the age of 91 days. Regarding the durability, replacing cement with ultra-fine fly ash (FA2) had a positive influence on the resistivity, chloride migration coefficient and alkali-silica reaction (ASR), and a negative influence on the carbonation resistance. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000582567100093 |
Publication Date |
2020-10-13 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0950-0618 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
7.4 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 7.4; 2020 IF: 3.169 |
|
|
Call Number |
UA @ admin @ c:irua:171815 |
Serial |
6498 |
|
Permanent link to this record |
|
|
|
|
Author |
Čevik, U.; Damla, N.; Van Grieken, R.; Vefa Akpinar, M. |
|
|
Title |
Chemical composition of building materials used in Turkey |
Type |
A1 Journal article |
|
Year |
2011 |
Publication |
Construction and building materials |
Abbreviated Journal |
|
|
|
Volume |
25 |
Issue |
4 |
Pages |
1546-1552 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The main goal of this work was to determine the chemical composition of building materials used in Turkey by utilizing energy dispersive X-ray fluorescence (EDXRF) spectrometry. Gas concrete, cement, sand, bricks, roofing tiles, marble, lime and gypsum materials were selected as building materials for this research. The chemical contents and their trace concentrations of the selected samples were determined. The most abundant oxides measured were generally SiO2, Al2O3, CaO, MgO, Fe2O3, K2O and SO3 for all samples. While the main chemical component of gas concrete, cement, sand and marble samples were SiO2 and CaO, brick and roofing tile mainly consisted of SiO2 and Al2O3. CaO and SO3 were major component of lime and gypsum samples, respectively. For U and Th concentrations in the samples, activities of 226Ra and 232Th were measured by utilizing gamma spectrometry. ANOVA and Pearson correlation analyses were performed on the studied data for statistical analysis. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000287379300007 |
Publication Date |
2010-09-22 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0950-0618 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:86448 |
Serial |
7653 |
|
Permanent link to this record |
|
|
|
|
Author |
Jain, R.; Rather, J.A. |
|
|
Title |
Voltammetric determination of antibacterial drug gemifloxacin in solubilized systems at multi-walled carbon nanotubes modified glassy carbon electrode |
Type |
A1 Journal article |
|
Year |
2011 |
Publication |
Colloids and surfaces: B : biointerfaces |
Abbreviated Journal |
|
|
|
Volume |
83 |
Issue |
2 |
Pages |
340-346 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
A sensitive electroanalytical method for determination of gemifloxacin in pharmaceutical formulation has been investigated on the basis of the enhanced electrochemical response at multi-walled carbon nanotubes modified glassy carbon electrode in the presence of CTAB. Solubilized system of different surfactants including SDS, Tween-20 and CTAB were taken for the study of electrochemical behaviour of gemifloxacin at modified electrode. The reduction peak current increases in the presence of CTAB while other surfactants show opposite effect. The modified electrode exhibits catalytic activity, high sensitivity, stability and is applicable over wide range of concentration for the determination of gemifloxacin. The mechanism of electrochemical reduction of gemifloxacin has been proposed on the basis of CV, SWV, DPV and coulometeric techniques. The proposed squarewave voltammetric method shows linearity over the concentration range 2.4715.5 μg/mL. The achieved limits of detection (LOD) and quantification (LOQ) are 0.90 ng/mL and 3.0 ng/mL respectively. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000287268000020 |
Publication Date |
2010-12-08 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0927-7765 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:98687 |
Serial |
8744 |
|
Permanent link to this record |
|
|
|
|
Author |
Jain, R.; Vikas; Rather, J.A. |
|
|
Title |
Voltammetric behaviour of drotaverine hydrochloride in surfactant media and its enhancement determination in Tween-20 |
Type |
A1 Journal article |
|
Year |
2011 |
Publication |
Colloids and surfaces: B : biointerfaces |
Abbreviated Journal |
|
|
|
Volume |
82 |
Issue |
2 |
Pages |
333-339 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Simple, sensitive and rapid adsorptive voltammetric behaviour of drotaverine hydrochloride onto the HMDE has been explored and validated in surfactant media by using cyclic, differential pulse and square-wave voltammetry. Addition of Tween-20 to the drotaverine hydrochloride containing electrolyte enhances the reduction current signal. The voltammograms of the drug with Tween-20 in phosphate buffers of pH 2.511.0 exhibit a single well defined reduction peak which may be due to the reduction of Cdouble bond; length as m-dashC group. The cyclic voltammetric studies indicated the reduction of drotaverine hydrochloride at the electrode surface through two electron irreversible step and diffusion-controlled. The peak current showed a linear dependence with the drug concentration over the range 0.87.2 μg mL−1. The calculated LOD and LOQ are 1.8 and 6.0 ng mL−1 by SWCAdSV and 8.1 and 27.2 ng mL−1 by DPCAdSV, respectively. The procedure was applied to the assay of the drug in tablet form with mean percentage recoveries of 100.2% with SWCAdSV and 99.7% with DPCAdSV. The validity of the proposed methods was further assessed by applying a standard addition technique. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000285858200010 |
Publication Date |
2010-09-16 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0927-7765 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:98686 |
Serial |
8742 |
|
Permanent link to this record |
|
|
|
|
Author |
Jain, R.; Rather, J.A. |
|
|
Title |
Stripping voltammetry of tinidazole in solubilized system and biological fluids |
Type |
A1 Journal article |
|
Year |
2011 |
Publication |
Colloids and surfaces: A: physicochemical and engineering aspects |
Abbreviated Journal |
|
|
|
Volume |
378 |
Issue |
|
Pages |
27-33 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The adsorptive voltammetric behaviour of tinidazole onto the HMDE was investigated and validated in solubilized system and biological fluids by CV, SWCAdSV and DPCAdSV. Addition of CTAB to the solution containing drug enhanced the peak current while anionic and non-ionic surfactants showed an opposite effect. The electrode process is irreversible and adsorption controlled. Various chemical and instrumental parameters affecting the monitored electroanalytical response were investigated and optimized for tinidazole determination. Under optimized conditions; the adsorptive stripping peak current is linear over the concentration range 7.0 × 10−9 to 6.2 × 10−7 mol/L with detection limit of 4.5 × 10−10 mol/L. The precision of the proposed method in terms of RSD is 1.2% and mean recovery of 100.01%. The applicability of proposed method is further extended to in vitro determination of the drug in biological fluids. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000289544600004 |
Publication Date |
2011-02-02 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0927-7757 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:98688 |
Serial |
8584 |
|
Permanent link to this record |
|
|
|
|
Author |
Jain, R.; Yadav, R.K.; Rather, J.A. |
|
|
Title |
Voltammetric assay of anti-vertigo drug betahistine hydrochloride in sodium lauryl sulphate |
Type |
A1 Journal article |
|
Year |
2010 |
Publication |
Colloids and surfaces: A: physicochemical and engineering aspects |
Abbreviated Journal |
|
|
|
Volume |
366 |
Issue |
|
Pages |
63-67 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Assay and electrochemical behaviour of betahistine hydrochloride in BrittonRobinsons (BR) buffer of pH range 2.512.0 at a glassy carbon electrode have been investigated. Addition of anionic surfactant (sodium lauryl sulphate) to the betahistine hydrochloride solution containing electrolyte enhanced the reduction current signal while neutral surfactant (Tween-20) and cationic surfactant cetyl trimethylammonium bromide (CTAB) showed an opposite effect. Voltammograms of betahistine hydrochloride exhibited a single wave. Based on reduction behaviour of betahistine hydrochloride, a direct square-wave voltammetric method has been developed for the assay of betahistine hydrochloride in pharmaceutical formulation. The proposed method has been validated as per ICH guideline. System and method precision in terms of RSD were 1.88% and 1.60% respectively, whereas the method accuracy was indicated by the recovery of 97.6101.9%. Reduction peak current was linear over the target concentration with correlation coefficient 0.998. The proposed method was successfully applied to the determination of betahistine hydrochloride in pharmaceutical formulation. The results were compared with those obtained by the reference high performance liquid chromatographic method. No significant differences were found between results of proposed and reference methods. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000280501800010 |
Publication Date |
2010-05-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0927-7757 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:98689 |
Serial |
8741 |
|
Permanent link to this record |
|
|
|
|
Author |
Bottari, F.; Blust, R.; De Wael, K. |
|
|
Title |
Bio(inspired) strategies for the electro-sensing of β-lactam antibiotics |
Type |
A1 Journal article |
|
Year |
2018 |
Publication |
Current opinion in electrochemistry |
Abbreviated Journal |
|
|
|
Volume |
10 |
Issue |
10 |
Pages |
143-148 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The dire previsions of the WHO on the so-called “post-antibiotic era” and the continuous and global rise of anti-microbial resistance, spurs our research community to find better ways to fight these threats. In light of this severe threat to human health many attempts have been made to develop efficient methods to detect antibiotic residues in different streams. The use of electrochemistry seems an inviting approach for on-site and fast monitoring. In this critical review, recent developments in the field of (bio) electro-sensing of 19-lactam antibiotics will be presented, with a focus on aptamers and molecularly imprinted polymers, the two main promises of a new generation of biosensors, yet to be fulfilled. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000442800000022 |
Publication Date |
2018-05-24 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2451-9103; 2451-9111 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
15 |
Open Access |
|
|
|
Notes |
; This work was financially supported by the University of Antwerp (BOF) and the Research Foundation – Flanders (FWO). ; |
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ admin @ c:irua:153744 |
Serial |
5488 |
|
Permanent link to this record |
|
|
|
|
Author |
Terzano, R.; Spagnuolo, M.; Medici, L.; Dorriné, W.; Janssens, K.; Ruggiero, P. |
|
|
Title |
Microscopic single particle characterization of zeolites synthesized in a soil polluted by copper or cadmium and treated with coal fly ash |
Type |
A1 Journal article |
|
Year |
2007 |
Publication |
Applied clay science |
Abbreviated Journal |
Appl Clay Sci |
|
|
Volume |
35 |
Issue |
1-2 |
Pages |
128-138 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000243825800016 |
Publication Date |
2006-09-12 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0169-1317 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
3.101 |
Times cited |
17 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 3.101; 2007 IF: 1.861 |
|
|
Call Number |
UA @ admin @ c:irua:62999 |
Serial |
5723 |
|
Permanent link to this record |
|
|
|
|
Author |
Dirtu, A.C.; Ravindra, K.; Roosens, L.; Van Grieken, R.; Neels, H.; Blust, R.; Covaci, A. |
|
|
Title |
Fast analysis of decabrominated diphenyl ether using low-pressure gas chromatography.electron-capture negative ionization mass spectrometry |
Type |
A1 Journal article |
|
Year |
2008 |
Publication |
Journal of chromatography : A |
Abbreviated Journal |
|
|
|
Volume |
1186 |
Issue |
|
Pages |
295-301 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000254884700024 |
Publication Date |
2007-07-23 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0021-9673 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:67546 |
Serial |
7957 |
|
Permanent link to this record |
|
|
|
|
Author |
Ravindra, K.; Godoi, A.F.L.; Bencs, L.; Van Grieken, R. |
|
|
Title |
Low-pressure gas chromatography-ion trap mass spectrometry for the fast determination of polycyclic aromatic hydrocarbons in air samples |
Type |
A1 Journal article |
|
Year |
2006 |
Publication |
Journal of chromatography: A: bibliography section |
Abbreviated Journal |
|
|
|
Volume |
1114 |
Issue |
2 |
Pages |
278-281 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000237542500016 |
Publication Date |
2006-04-05 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:57705 |
Serial |
8188 |
|
Permanent link to this record |
|
|
|
|
Author |
Godoi, A.F.L.; Van Vaeck, L.; Van Grieken, R. |
|
|
Title |
Use of solid-phase microextraction for the detection of acetic acid by ion-trap gas chromatography-mass spectrometry and application to indoor levels in museums |
Type |
A1 Journal article |
|
Year |
2005 |
Publication |
Journal of chromatography: A: bibliography section |
Abbreviated Journal |
|
|
|
Volume |
1067 |
Issue |
|
Pages |
331-336 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000227925800032 |
Publication Date |
2005-01-26 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:51590 |
Serial |
8723 |
|
Permanent link to this record |
|
|
|
|
Author |
Godoi, A.F.L.; Ravindra, K.; Godoi, R.H.M.; Andrade, S.J.; Santiago-Silva, M.; Van Vaeck, L.; Van Grieken, R. |
|
|
Title |
Fast chromatographic determination of polycyclic aromatic hydrocarbons in aerosol samples from sugar cane burning |
Type |
A1 Journal article |
|
Year |
2004 |
Publication |
Journal of chromatography: A: bibliography section |
Abbreviated Journal |
|
|
|
Volume |
1027 |
Issue |
|
Pages |
49-53 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000188498900008 |
Publication Date |
2003-11-15 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:43528 |
Serial |
7959 |
|
Permanent link to this record |
|
|
|
|
Author |
Godoi, A.F.L.; Vilegas, W.; Godoi, R.H.M.; Van Vaeck, L.; Van Grieken, R. |
|
|
Title |
Application of low-pressure gas chromatography-io-trap mass spectrometry to the analysis of the eseential oil of Turnera diffusa (Ward.) Urb |
Type |
A1 Journal article |
|
Year |
2004 |
Publication |
Journal of chromatography: A: bibliography section |
Abbreviated Journal |
|
|
|
Volume |
1027 |
Issue |
|
Pages |
127-130 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000188498900018 |
Publication Date |
2003-10-14 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:43529 |
Serial |
7480 |
|
Permanent link to this record |
|
|
|
|
Author |
Akbulut, S.; Cevik, U.; Van, A.A.; De Wael, K.; Van Grieken, R. |
|
|
Title |
Precision and accuracy of ST-EDXRF performance for As determination comparing with ICP-MS and evaluation of As deviation in the soil media |
Type |
A1 Journal article |
|
Year |
2014 |
Publication |
Chemosphere |
Abbreviated Journal |
Chemosphere |
|
|
Volume |
96 |
Issue |
|
Pages |
16-22 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The present study was conducted to (i) determine the precision and accuracy of arsenic measurement in soil samples using ST-EDXRF by comparison with the results of ICP-MS analyses and (ii) identify the relationship of As concentration with soil characteristics. For the analysis of samples, inductively coupled plasma mass spectrometry (ICP-MS) and energy dispersive X-ray fluorescence spectrometry (EDXRF) were performed. According to the results found in the soil samples, the addition of HCl to HNO3, used for the digestion gave significant variations in the recovery of As. However, spectral interferences between peaks for As and Pb can affect detection limits and accuracy for XRF analysis. When comparing the XRF and ICP-MS results a correlation was observed with R2 = 0.8414. This means that using a ST-EDXRF spectrometer, it is possible to achieve accurate and precise analysis by the calibration of certified reference materials and choosing an appropriate secondary target. On the other hand, with regard to soil characteristics analyses, the study highlighted that As is mostly anthropogenically enriched in the studied area. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000328182200002 |
Publication Date |
2013-08-14 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0045-6535; 1879-1298 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
4.208 |
Times cited |
5 |
Open Access |
|
|
|
Notes |
; ; |
Approved |
Most recent IF: 4.208; 2014 IF: 3.340 |
|
|
Call Number |
UA @ admin @ c:irua:109437 |
Serial |
5782 |
|
Permanent link to this record |
|
|
|
|
Author |
Serneels, S.; Faber, K.; Verdonck, T.; van Espen, P.J. |
|
|
Title |
Case specific prediction intervals for tri-PLS1 : the full local linearisation |
Type |
A1 Journal article |
|
Year |
2011 |
Publication |
Chemometrics and intelligent laboratory systems |
Abbreviated Journal |
|
|
|
Volume |
108 |
Issue |
2 |
Pages |
93-99 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
A new method to estimate case specific prediction uncertainty for univariate trilinear partial least squares (tri-PLS1) regression is introduced. This method is, from a theoretical point of view, the most exact finite sample approximation to true prediction uncertainty that has been reported up till now. Using the new method, different error sources can be propagated, which is an advantage that cannot be offered by data driven approaches such as the bootstrap. In a concise example, it is illustrated how the method can be applied. In the Appendix, efficient algorithms are presented to compute the estimates required. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000295310000002 |
Publication Date |
2011-05-12 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0169-7439; 1873-3239 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:92788 |
Serial |
7580 |
|
Permanent link to this record |
|
|
|
|
Author |
Dekov, V.M.; Vanlierde, E.; Billström, K.; Gatto Rotondo, G.; van Meel, K.; Darchuk, L.; Van Grieken, R.; et al. |
|
|
Title |
Ferrihydrite precipitation in groundwater-fed river systems (Nete and Demer river basins, Belgium) : insights from a combined Fe-Zn-Sr-Nd-Pb-isotope study |
Type |
A1 Journal article |
|
Year |
2014 |
Publication |
Chemical geology |
Abbreviated Journal |
|
|
|
Volume |
386 |
Issue |
|
Pages |
1-15 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Two groundwater-fed river systems (Nete and Demer, Belgium) carry red suspended material that settles on the river bed forming red sediments. The local aquifer that feeds these river systems is a glauconite-rich sand, which provides most of the dissolved Fe to the rivers. The solid component of these systems, i.e., the red suspended material and sediments, has a simple mineralogy (predominantly ferrihydrite), but shows a complex geochemistry pointing out the different processes contributing to the river chemistry: (1) the red sediments have higher transition metal (excluding Cu) and detrital element (e.g., Si, Al, K, Rb, etc.) concentrations than the red suspended matter because of their longer residence time in the river and higher contribution of the background (aquifer) component, respectively; (2) the red suspended material and sediments have inherited their rare earth element (REE) patterns from the aquifer; (3) the origin of Sr present in the red suspended matter and red sediments is predominantly marine (i.e., Quaternary calcareous rocks), but a small amount is geogenic (i.e., from detrital rocks); (4) Pb in both solids originates mostly from anthropogenic and geogenic sources; (5) all of the anthropogenic Pb in the red suspended material and sediments is hosted by the ferrihydrite; (6) Nd budget of the red riverine samples is controlled by the geogenic source and shows little anthropogenic component; (7) the significant Fe- and Zn-isotope fractionations are in line with the previous studies. Their fractionation patterns do not correlate, suggesting that the processes controlling the isotope geochemistry of Fe and Zn are different: oxidation/reduction most likely governs the Fe-isotope fractionation, whereas adsorption/desorption or admixing of anthropogenic sources controls the isotope fractionation of Zn. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000345441000001 |
Publication Date |
2014-08-08 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0009-2541 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:118323 |
Serial |
7962 |
|
Permanent link to this record |
|
|
|
|
Author |
Potgieter-Vermaak, S.S.; Potgieter, J.H.; Worobiec, A.; Van Grieken, R.; Marjanovic, L.; Moeketsi, S. |
|
|
Title |
Fingerprinting of South African ordinary Portland cements, cement blends and mortars for identification purposes: discrimination with starplots and PCA |
Type |
A1 Journal article |
|
Year |
2007 |
Publication |
Cement and concrete research |
Abbreviated Journal |
|
|
|
Volume |
37 |
Issue |
6 |
Pages |
834-843 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000247613800003 |
Publication Date |
2007-02-26 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0008-8846 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:63909 |
Serial |
7970 |
|
Permanent link to this record |
|
|
|
|
Author |
Potgieter-Vermaak, S.S.; Potgieter, J.H.; Belleil, M.; DeWeerdt, F.; Van Grieken, R. |
|
|
Title |
The application of Raman spectrometry to the investigation of cement: part 2: a micro-Raman study of OPC, slag and fly ash |
Type |
A1 Journal article |
|
Year |
2006 |
Publication |
Cement and concrete research |
Abbreviated Journal |
|
|
|
Volume |
36 |
Issue |
4 |
Pages |
663-670 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000236781200007 |
Publication Date |
2005-11-03 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0008-8846 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:57471 |
Serial |
7483 |
|
Permanent link to this record |
|
|
|
|
Author |
Potgieter-Vermaak, S.S.; Potgieter, J.H.; Van Grieken, R. |
|
|
Title |
The application of Raman spectrometry to investigate and characterize cement: part I: a review |
Type |
A1 Journal article |
|
Year |
2006 |
Publication |
Cement and concrete research |
Abbreviated Journal |
|
|
|
Volume |
36 |
Issue |
4 |
Pages |
656-662 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000236781200006 |
Publication Date |
2005-11-03 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0008-8846 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:57470 |
Serial |
7482 |
|
Permanent link to this record |
|
|
|
|
Author |
Benito, P.; Monti, M.; de Nolf, W.; Nuyts, G.; Janssens, K.; et al. |
|
|
Title |
Improvement in the coating homogeneity in electrosynthesized Rh structured catalysts for the partial oxidation of methane |
Type |
A1 Journal article |
|
Year |
2015 |
Publication |
Catalysis today |
Abbreviated Journal |
Catal Today |
|
|
Volume |
246 |
Issue |
|
Pages |
154-164 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The precipitation of Rh/Mg/Al and Rh/Al hydroxides on the surface of FeCrAlloy foams by a base electrogeneration method was investigated to improve the properties of the deposited film (homogeneity and composition) and therefore the performances of the structured catalysts, obtained by calcination, in the Catalytic Partial Oxidation of CH4 to syngas. The work focussed on decreasing current gradients within open-cell foam cylinders by increasing the number of electrical contacts from 1 to 3 points to promote a more homogeneous precipitation of the hydroxides. Electrochemical and catalytic tests as well as SEM/EDS and mu-XRFIXRD analyses allowed to correlate the effect of the number of electrical contact points with materials properties. Lastly, syntheses were performed on Pt plates to study the effect of the electrical behaviour and shape of the support on the composition of the film. A more homogeneous coating of the foam surface was achieved by adopting a configuration with 3 contact points since the reduction of nitrates and water molecules that generates the basic media in the vicinity of the support was enhanced. Layer thicknesses up to 5-15 mu m were deposited; however, the sequential precipitation of a film with composition closer to the expected one and a layer enriched in Al and Rh (outer layer) was not avoided. The improvement in the coating gave rise to enhanced performances for a sample prepared at -1.1 V for 3000 s. Contrarily, the low adherence of the outer layer in a sample prepared at -1.2 V for 2000 s during both calcination and catalytic tests may be responsible of the unexpected decrease in catalytic performances. The same sequential precipitation was observed by performing the syntheses on Pt plates, showing that the electrical nature the support did not play a key role on this phenomenon. (C) 2014 Elsevier B.V. All rights reserved. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000349998300020 |
Publication Date |
2014-10-31 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0920-5861 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
4.636 |
Times cited |
14 |
Open Access |
|
|
|
Notes |
; The financial support from the Ministero per l'Istruzione, l'Universita e la Ricerca (MIUR, Roma, I) is gratefully acknowledged. The authors thank D. Grolimund and C.N. Borca for assisting the mu XRF/XRD conducted experiments at MicroXAS Beamline of SLS Thanks are due to Porvair for supplying FeCrAlloy foams. ; |
Approved |
Most recent IF: 4.636; 2015 IF: 3.893 |
|
|
Call Number |
UA @ admin @ c:irua:124616 |
Serial |
5656 |
|
Permanent link to this record |
|
|
|
|
Author |
Zwozdziak, A.; Sowka, I.; Krupińska, B.; Zwozdziak, J.; Nych, A. |
|
|
Title |
Infiltration or indoor sources as determinants of the elemental composition of particulate matter inside a school in Wroclaw, Poland? |
Type |
A1 Journal article |
|
Year |
2013 |
Publication |
Building and environment |
Abbreviated Journal |
|
|
|
Volume |
66 |
Issue |
|
Pages |
173-180 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Children's exposure to air pollution requires a focus on air quality in places where they spend most time, e.g. in schools. Therefore, understanding how indoor elemental concentrations relate the outdoor ones is necessary to create healthy indoor school environment. The aims of this study were to examine the elemental composition of particulate matter (PM1, PM2.5, PM10) in the school and also to investigate to what degree indoor elemental concentrations are affected by outdoor air or generated inside the school. The measurements were performed inside and outside the public school building in the centre of the city. It was observed that concentrations of most elements were higher at school than outside. The dominant elements in PM1 both indoors and outdoors were S, Cl, K, and Zn. PM2.5 and PM10 fractions inside the school were clearly enriched in elements of mineral origin, additionally S, Zn, K and Cl were also present in high concentrations both indoors and outdoors. Results suggested that a significant contribution to indoor Zn, Pb and S concentrations in the PM2.5 fraction was from penetration of outdoor air. 88%, 80% and 90% of the observed total variations in indoor concentrations of Zn, Pb, and S were explained by the linear relationship between indoor and outdoor concentrations. The lack of correlation between indoor and outdoor concentrations obtained for Si, Ca, Ti, Sr indicated that these metals were more likely to originate from indoor sources. (C) 2013 Elsevier Ltd. All rights reserved. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000321423500017 |
Publication Date |
2013-05-09 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0360-1323 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:109788 |
Serial |
8087 |
|
Permanent link to this record |
|
|
|
|
Author |
Cánovas, R.; Blondeau, P.; Andrade, F.J. |
|
|
Title |
Modulating the mixed potential for developing biosensors: Direct potentiometric determination of glucose in whole, undiluted blood |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Biosensors & Bioelectronics |
Abbreviated Journal |
Biosens Bioelectron |
|
|
Volume |
163 |
Issue |
|
Pages |
112302-112306 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The growing demand for tools to generate chemical information in decentralized settings is creating a vast range of opportunities for potentiometric sensors, since their combination of robustness, simplicity of operation and cost can hardly be rivalled by any other technique. In previous works, we have shown that the mixed potential of a Pt electrode can be controlled with analytical purposes using a coating of Nafion, thus providing a way to develop a potentiometric biosensor for glucose. Unfortunately, the linear range of this device did not match the relevant clinical range for glucose in blood. This work presents a novel strategy to control the mixed potential that allows the development of a potentiometric biosensor for the direct detection of glucose in whole, undiluted blood without any sample pretreatment. By changing the ionomer, the analytical response can be tuned, shifting the linear range while keeping the sensitivity. Aquivion, a polyelectrolyte from the same family as Nafion, is used to stabilize the mixed potential of a platinized paper-based electrode, to entrap the enzyme and to reduce the interference from negatively charged species. Factors affecting the generation of the signal and the principle of detection are discussed. Optimization of the biosensor composition was achieved with particular focus on the characterization of the linear range and sensitivity. The accurate measurement of blood sugar levels in a single drop of whole blood with excellent recovery is presented. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2020-05-18 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0956-5663 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
12.6 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 12.6; 2020 IF: 7.78 |
|
|
Call Number |
UA @ admin @ c:irua:184382 |
Serial |
8271 |
|
Permanent link to this record |
|
|
|
|
Author |
Ciftci, S.; Cánovas, R.; Neumann, F.; Paulraj, T.; Nilsson, M.; Crespo, G.A.; Madaboosi, N. |
|
|
Title |
The sweet detection of rolling circle amplification : glucose-based electrochemical genosensor for the detection of viral nucleic acid |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Biosensors & Bioelectronics |
Abbreviated Journal |
Biosens Bioelectron |
|
|
Volume |
151 |
Issue |
|
Pages |
112002-112008 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Herein, an isothermal padlock probe-based assay for the simple and portable detection of pathogens coupled with a glucose oxidase (GOx)-based electrochemical readout is reported. Infectious diseases remain a constant threat on a global scale, as in recurring pandemics. Rapid and portable diagnostics hold the promise to tackle the spreading of diseases and decentralising healthcare to point-of-care needs. Ebola, a hypervariable RNA virus causing fatalities of up to 90% for recent outbreaks in Africa, demands immediate attention for bedside diagnostics. The design of the demonstrated assay consists of a rolling circle amplification (RCA) technique, responsible for the generation of nucleic acid amplicons as RCA products (RCPs). The RCPs are generated on magnetic beads (MB) and subsequently, connected via streptavidin-biotin bonds to GOx. The enzymatic catalysis of glucose by the bound GOx allows for an indirect electrochemical measurement of the DNA target. The RCPs generated on the surface of the MB were confirmed by scanning electron microscopy, and among other experimental conditions such as the type of buffer, temperature, concentration of GOx, sampling and measurement time were evaluated for the optimum electrochemical detection. Accordingly, 125 μg mL−1 of GOx with 5 mM glucose using phosphate buffer saline (PBS), monitored for 1 min were selected as the ideal conditions. Finally, we assessed the analytical performance of the biosensing strategy by using clinical samples of Ebola virus from patients. Overall, this work provides a proof-of-concept bioassay for simple and portable molecular diagnostics of emerging pathogens using electrochemical detection, especially in resource-limited settings. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2019-12-30 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0956-5663 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
12.6 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 12.6; 2020 IF: 7.78 |
|
|
Call Number |
UA @ admin @ c:irua:184379 |
Serial |
8630 |
|
Permanent link to this record |
|
|
|
|
Author |
Moro, G.; Bottari, F.; Van Loon, J.; Du Bois, E.; De Wael, K.; Moretto, L.M. |
|
|
Title |
Disposable electrodes from waste materials and renewable sources for (bio) electroanalytical applications |
Type |
A1 Journal article |
|
Year |
2019 |
Publication |
Biosensors and bioelectronics |
Abbreviated Journal |
Biosens Bioelectron |
|
|
Volume |
146 |
Issue |
146 |
Pages |
111758 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Product development |
|
|
Abstract |
The numerous advantages of disposable and screen-printed electrodes (SPEs) particularly in terms of portability, sensibility, sensitivity and low-cost led to the massive application of these electroanalytical devices. To limit the electronic waste and recover precious materials, new recycling processes were developed together with alternative SPEs fabrication procedures based on renewable, biocompatible sources or waste materials, such as paper, agricultural byproducts or spent batteries. The increased interest in the use of eco-friendly materials for electronics has given rise to a new generation of highly performing green modifiers. From paper based electrodes to disposable electrodes obtained from CD/DVD, in the last decades considerable efforts were devoted to reuse and recycle in the field of electrochemistry. Here an overview of recycled and recyclable disposable electrodes, sustainable electrode modifiers and alternative fabrication processes is proposed aiming to provide meaningful examples to redesign the world of disposable electrodes. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000497250600003 |
Publication Date |
2019-10-07 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0956-5663 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
7.78 |
Times cited |
2 |
Open Access |
|
|
|
Notes |
; This research received funding from FWO and IOF (UAntwerpen). ; |
Approved |
Most recent IF: 7.78 |
|
|
Call Number |
UA @ admin @ c:irua:164563 |
Serial |
5578 |
|
Permanent link to this record |
|
|
|
|
Author |
Amiri-Aref, M.; Raoof, J.B.; Kiekens, F.; De Wael, K. |
|
|
Title |
Mixed hemi/ad-micelles coated magnetic nanoparticles for the entrapment of hemoglobin at the surface of a screen-printed carbon electrode and its direct electrochemistry and electrocatalysis |
Type |
A1 Journal article |
|
Year |
2015 |
Publication |
Biosensors and bioelectronics |
Abbreviated Journal |
Biosens Bioelectron |
|
|
Volume |
74 |
Issue |
|
Pages |
518-525 |
|
|
Keywords |
A1 Journal article; Pharmacology. Therapy; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
An efficient procedure for the physical entrapment of proteins within a biocompatible matrix and their immobilization on electrode surfaces is of utmost importance in the fabrication of biosensors. In this work, the magnetic entrapment of hemoglobin (Hb) at the surface of a screen-printed carbon electrode (SPCE), through mixed hemi/ad-micelles (MHAM) array of positively charged surfactant supported iron oxide magnetic nanoparticles (Mag-NPs), is reported. The Hb/MHAM@Mag-NPs biocomposite is captured at SPCE by a super magnet (Hb/MHAM@Mag-NPs/SPCE). To gain insight in the configuration of the mixed hemi/ad-micelles of CTAB at Mag-NPs, zeta-potential measurements were performed. The entrapment of Hb at MHAM@Mag-NPs was confirmed by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and Fourier transform infrared spectroscopy (FT-IR). Direct electron transfer of the Hb intercalated into the composite film showed a pair of well-defined quasi-reversible redox peak at formal potential of −0.255 V vs. Ag/AgCl corresponding to heme Fe(III)/Fe(II) redox couple. It shows that the MHAM@Mag-NPs composite could increase the adsorption ability for Hb, thus provides a facile direct electron transfer between the Hb and the substrate. The proposed biosensor showed excellent electrocatalytic activity to the H2O2 reduction in the wide concentration range from 5.0 to 300.0 µM obtained by amperometric measurement. The MichaelisMenten constant (Km) value of Hb at the modified electrode is 55.4 µM, showing its high affinity. Magnetic entrapment offers a promising design for fast, convenient and effective immobilization of protein within a few minutes for determination of the target molecule in low sample volume at disposable cost-effective SPCE. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000360772800071 |
Publication Date |
2015-07-05 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0956-5663 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
7.78 |
Times cited |
14 |
Open Access |
|
|
|
Notes |
; We are thankful for the BOF financial support from the University of Antwerp and Hercules financial support (SEM). ; |
Approved |
Most recent IF: 7.78; 2015 IF: 6.409 |
|
|
Call Number |
UA @ admin @ c:irua:126535 |
Serial |
5731 |
|
Permanent link to this record |
|
|
|
|
Author |
Daems, D.; De Wael, K.; Vissenberg, K.; Van Camp, G.; Nagels, L. |
|
|
Title |
Potentiometric sensors doped with biomolecules as a new approach to small molecule/biomolecule binding kinetics analysis |
Type |
A1 Journal article |
|
Year |
2014 |
Publication |
Biosensors and bioelectronics |
Abbreviated Journal |
Biosens Bioelectron |
|
|
Volume |
54 |
Issue |
|
Pages |
515-520 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; Integrated Molecular Plant Physiology Research (IMPRES); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The most successful binding kinetics analysis systems at this moment include surface plasmon resonance (SPR), quartz microcrystal balance (QMB) and surface acoustic wave (SAW). Although these are powerful methods, they generally are complex, expensive and require the use of monolayers. Here, we report on potentiometric sensors as an inexpensive and simple alternative to do binding kinetics analysis between small molecules in solution and biomolecules (covalently) attached in a biopolymer sensor coating layer. As an example, dopamine and an anti-dopamine aptamer were used as the small molecule and the biomolecule respectively. Binding between both follows a Langmuir adsorption type model and creates a surface potential. The system operates in Flow Injection Analysis mode (FIA). Besides being an interesting new binding kinetics tool, the approach allows systematic design of potentiometric biosensors (in the present study a dopamine sensor), and gives new insights into the functioning of ion-selective electrodes (ISEs). |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000333071500077 |
Publication Date |
2013-11-24 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0956-5663 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
7.78 |
Times cited |
10 |
Open Access |
|
|
|
Notes |
; Financial support for this work was provided by the University of Antwerp by granting L.N. and G.V.C. a BOF interdisciplinary research project. ; |
Approved |
Most recent IF: 7.78; 2014 IF: 6.409 |
|
|
Call Number |
UA @ admin @ c:irua:111678 |
Serial |
5780 |
|
Permanent link to this record |
|
|
|
|
Author |
Pilehvar, S.; Rather, J.A.; Dardenne, F.; Robbens, J.; Blust, R.; De Wael, K. |
|
|
Title |
Carbon nanotubes based electrochemical aptasensing platform for the detection of hydroxylated polychlorinated biphenyl in human blood serum |
Type |
A1 Journal article |
|
Year |
2014 |
Publication |
Biosensors and bioelectronics |
Abbreviated Journal |
Biosens Bioelectron |
|
|
Volume |
54 |
Issue |
|
Pages |
78-84 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
A novel strategy to sense target molecules in human blood serum is achieved by immobilizing aptamers (APTs) on multiwalled carbon nanotubes (MWCNT) modified electrodes. In this work, the aminated aptamer selected for hydroxylated polychlorinated biphenyl (OHPCB) was covalently immobilized on the surface of the MWCNTCOOH modified glassy carbon electrode through amide linkage. The aptamers function as recognition probes for OHPCB by the binding induced folding of the aptamer. The developed aptasensing device was characterized by Electrochemical Impedance Spectroscopy (EIS), Atomic Force Microscopy (AFM) and Fourier Transform Infrared Spectroscopy (FTIR). The aptasensor displayed excellent performance for OHPCB detection with a linear range from 0.16 to 7.5 μM. The sensitivity of the developed aptasensing platform is improved (1×10−8 M) compared to the published report (1×10−6 M) for the determination of OH-PCB (Turner et al., 2007). The better performance of the sensor is due to the unique platform, i.e. the presence of APTs onto electrodes and the combination with nanomaterials. The aptamer density on the electrode surface was estimated by chronocoulometry and was found to be 1.4×1013 molecules cm−2. The validity of the method and applicability of the aptasensor was successfully evaluated by the detection of OHPCB in a blood serum sample. The described approach for aptasensing opens up new perspectives in the field of biomonitoring providing a device with acceptable stability, high sensitivity, good accuracy and precision. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000333071500012 |
Publication Date |
2013-11-01 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0956-5663 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
7.78 |
Times cited |
40 |
Open Access |
|
|
|
Notes |
; We are thankful to UA-DOCPRO and BELSPO for financial support (respectively S. Pilehvar and J. Ahmad Rather). We also thank Prof. A. Covaci (UA) for the kind gift of human blood serum samples. Special thanks to Prof. L Van Vaeck and Y. Vercammen (UA) for AFM imaging and Prof. V. Meynen and M. Kus (LADCA, UA) for performing IR measurements. ; |
Approved |
Most recent IF: 7.78; 2014 IF: 6.409 |
|
|
Call Number |
UA @ admin @ c:irua:111262 |
Serial |
5495 |
|
Permanent link to this record |
|
|
|
|
Author |
Moro, G.; Bottari, F.; Liberi, S.; Covaceuszach, S.; Cassetta, A.; Angelini, A.; De Wael, K.; Moretto, L.M. |
|
|
Title |
Covalent immobilization of delipidated human serum albumin on poly(pyrrole-2-carboxylic) acid film for the impedimetric detection of perfluorooctanoic acid |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Bioelectrochemistry |
Abbreviated Journal |
Bioelectrochemistry |
|
|
Volume |
134 |
Issue |
|
Pages |
107540 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The immobilization of biomolecules at screen printed electrodes for biosensing applications is still an open challenge. To enrich the toolbox of bioelectrochemists, graphite screen printed electrodes (G-SPE) were modified with an electropolymerized film of pyrrole-2-carboxilic acid (Py-2-COOH), a pyrrole derivative rich in carboxylic acid functional groups. These functionalities are suitable for the covalent immobilization of biomolecular recognition layers. The electropolymerization was first optimized to obtain stable and conductive polymeric films, comparing two different electrolytes: sodium dodecyl sulphate (SDS) and sodium perchlorate. The G-SPE modified with Py-2-COOH in 0.1 M SDS solution showed the required properties and were further tested. A proof-of-concept study for the development of an impedimetric sensor for perfluorooctanoic acid (PFOA) was carried out using the delipidated human serum albumin (hSA) as bioreceptor. The data interpretation was supported by size exclusion chromatography and small-angle X-ray scattering (SEC-SAXS) analysis of the bioreceptor-target complex and the preliminary results suggest the possibility to further develop this biosensing strategy for toxicological and analytical studies. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000579727300004 |
Publication Date |
2020-04-27 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1567-5394 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
5 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 5; 2020 IF: 3.346 |
|
|
Call Number |
UA @ admin @ c:irua:172494 |
Serial |
6477 |
|
Permanent link to this record |
|
|
|
|
Author |
De Wael, K.; Bashir, Q.; van Vlierberghe, S.; Dubruel, P.; Heering, H.A.; Adriaens, A. |
|
|
Title |
Electrochemical determination of hydrogen peroxide with cytochrome c peroxidase and horse heart cytochrome c entrapped in a gelatin hydrogel |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
Bioelectrochemistry: an international journal devoted to electrochemical aspects of biology and biological aspects of electrochemistry |
Abbreviated Journal |
Bioelectrochemistry |
|
|
Volume |
83 |
Issue |
|
Pages |
15-18 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
A novel and versatile method, based on a membrane-free enzyme electrode in which both the enzyme and a mediator protein are entrapped in a gelatine hydrogel was developed for the fabrication of biosensors. As a proof of principle, we prepared a hydrogen peroxide biosensor by successfully entrapping both horse heart cytochrome c (HHC) and Saccharomyces cerevisae cytochrome c peroxidase (CCP) in a gelatin matrix which is immobilized on a gold electrode. This electrode was first pretreated with 6-mercaptohexanol. The biosensor displayed a rapid response and an expanded linear response range from 0 to 0.3 mM (R = 0.987) with a detection limit of 1 × 10− 5 M in a HEPES buffer solution (pH 7.0). This method of encapsulation is now further investigated for industrial biosensor applications. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000297962500003 |
Publication Date |
2011-08-03 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1567-5394 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
3.346 |
Times cited |
31 |
Open Access |
|
|
|
Notes |
; Karolien De Wael is grateful to the Research Foundation-Flanders (FWO, Belgium) for her postdoctoral fellowship. ; |
Approved |
Most recent IF: 3.346; 2012 IF: 3.947 |
|
|
Call Number |
UA @ admin @ c:irua:92067 |
Serial |
5589 |
|
Permanent link to this record |
|
|
|
|
Author |
Mmari, A.G.; Potgieter-Vermaak, S.S.; Bencs, L.; McCrindle, R.I.; Van Grieken, R. |
|
|
Title |
Elemental and ionic components of atmospheric aerosols and associated gaseous pollutants in and near Dar es Salaam, Tanzania |
Type |
A1 Journal article |
|
Year |
2013 |
Publication |
Atmospheric environment : an international journal |
Abbreviated Journal |
|
|
|
Volume |
77 |
Issue |
|
Pages |
51-61 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Elemental and water-soluble ionic compounds (WSICs) of atmospheric aerosols (total suspended particulate TSP) and some gaseous pollutants (SO2, NO2 and O3) from a coastal, semi-urban and rural site in and near Dar es Salaam, Tanzania were investigated during dry and wet seasons of January 2005November 2007. Na+, Ca2+, SO42−, NO3− and Cl− made up the dominant fraction of WSICs during the dry season with average concentrations ranging from non-detectable (n.d.)5.4, 0.262.6, 0.7414.7, 0.41.5 and 1.13.4 μg m−3, respectively, while in the wet season, from n.d. up to 1.7, 1.2, 4.4, 2.1 and 3.0 μg m−3, respectively. The total air concentrations of the detected elements (Al, Si, S, Cl, K, Ca, Fe and Zn) showed seasonal and site-specific variation in the range of 7.526.6 with an average of 14.5 μg m−3. Most of the air concentrations of pollutants were observed to decrease with increasing distance from the coastal site, which is under urban and industrial pollutant emissions. Sulphur and nitrogen oxidation ratios during the dry season ranged from 0.08 to 0.91 and 0.013 to 0.049, respectively, while they were between 0.090.65 and 0.0020.095, respectively, in the wet season. These values indicate the photochemical oxidation of SO2 and a high extent of NO3−formation in the atmosphere. Neutralization ratios revealed the presence of acidic SO42− and NO3− aerosols. Principal component analysis identified sea spray, local combustion, vehicular traffic, biomass burning and re-suspended road dust as dominant sources of aerosols at the studied coastal and semi-urban sites. However, at the rural site, besides sea spray, crustal sources, soil dust re-suspension and long-range transport are the possible origins of suspended particulates. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000324848500006 |
Publication Date |
2013-05-01 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1352-2310 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:108096 |
Serial |
7882 |
|
Permanent link to this record |