|
“Evaluation of energy-dispersive x-ray-spectra with the aid of expert systems”. Janssens K, van Espen P, Analytica chimica acta 191, 169 (1986). http://doi.org/10.1016/S0003-2670(00)86306-0
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/S0003-2670(00)86306-0
|
|
|
“Evaluation of the ArmstrongBuseck correction for automated electron probe X-ray microanalysis of particles”. Storms HM, Janssens KH, Török SB, Van Grieken RE, X-ray spectrometry 18, 45 (1989). http://doi.org/10.1002/XRS.1300180203
Abstract: The ArmstrongBuseck correction for absorption effects in electron probe x-ray microanalysis of particles considers seven specific particle shapes, and for these geometries exact correction equations are used. This procedure implies that the analyst has to associate the particle to be analysed with a certain particle type; an arbitrary relative thickness is sometimes assumed. A theoretical study was made of this absorption correction as a function of the particle composition, type and thickness for micrometre-sized particles. It appears that a correct choice of the particle type is critical. However, when the analytical results are normalized to 100%, the differences between the models are much less pronounced, and it is justified to assume a spherical model in all cases.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300180203
|
|
|
“Examination of historical paintings by state-of-the-art hyperspectral imaging methods : from scanning infra-red spectroscopy to computed X-ray laminography”. Legrand S, Vanmeert F, van der Snickt G, Alfeld M, de Nolf W, Dik J, Janssens K, Heritage science 2, 13 (2014). http://doi.org/10.1186/2050-7445-2-13
Abstract: The development of advanced methods for non-destructive selective imaging of painted works of art at the macroscopic level based on radiation in the X-ray and infrared range of the electromagnetic spectrum are concisely reviewed. Such methods allow to either record depth-selective, element-selective or species-selective images of entire paintings. Camera-based full field methods (that record the image data in parallel) can be discerned next to scanning methods (that build up distributions in a sequential manner by scanning a beam of radiation over the surface of an artefact). Six methods are discussed: on the one hand, macroscopic X-ray fluorescence and X-ray diffraction imaging and X-ray laminography and on the other hand macroscopic Mid and Near Infrared hyper- and full spectral imaging and Optical Coherence Tomography. These methods can be considered to be improved versions of the well-established imaging methods employed worldwide for examination of paintings, i.e., X-ray radiography and Infrared reflectography. Possibilities and limitations of these new imaging techniques are outlined.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1186/2050-7445-2-13
|
|
|
“A flexible and accurate quantification algorithm for EPXMA based on thin-film element yields”. Schalm O, Janssens K, Spectrochimica acta: part B : atomic spectroscopy 58, 669 (2003). http://doi.org/10.1016/S0584-8547(02)00290-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(02)00290-2
|
|
|
“A general Monte-Carlo simulation of energy-dispersive X-ray fluorescence spectrometers : 1 : unpolarized radiation, homogenious samples”. Vincze L, Janssens K, Adams F, Spectrochimica acta: part B : atomic spectroscopy 48, 553 (1993). http://doi.org/10.1016/0584-8547(93)80060-8
Abstract: A general Monte Carlo program for the simulation of X-ray fluorescence (XRF) spectrometers is presented. The global layout of the program is discussed and the way in which variance reduction techniques have been employed to improve the efficiency of the code is described. For the case of polychromatic excitation in a direct excitation energy-dispersive (ED) XRF instrument, experimentally collected ED-XRF spectra are compared with simulated spectral distributions. Applications of the software in the field of quantitative analysis and thickness estimation of samples of intermediate thickness illustrate the potential of the method.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0584-8547(93)80060-8
|
|
|
“High energy X-ray microscopy for characterisation of fuel particles”. Salbu B, Krekling T, Lind OC, Oughton DH, Drakopoulos M, Simionovici AS, Snigireva I, Snigirev A, Weitkamp T, Adams F, Janssens K, Kashparov VA, Nuclear instruments and methods in physics research : A: accelerators, spectrometers, detectors and associated equipment 467, 1249 (2001). http://doi.org/10.1016/S0168-9002(01)00641-6
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.362
DOI: 10.1016/S0168-9002(01)00641-6
|
|
|
“High-resolution X-ray fluorescence microtomography of homogeneous samples”. Simionovici AS, Chukalina M, Schroer C, Drakopoulos M, Snigirev A, Snigireva I, Lengeler B, Janssens K, Adams F, IEEE transactions on nuclear science 47, 2736 (2000). http://doi.org/10.1109/23.901180
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.171
DOI: 10.1109/23.901180
|
|
|
“Impact of urban street canyon architecture on local atmospheric pollutant levels and magneto-chemical PM10 composition : an experimental study in Antwerp, Belgium”. Hofman J, Castanheiro A, Nuyts G, Joosen S, Spassov S, Blust R, De Wael K, Lenaerts S, Samson R, The science of the total environment 712, 135534 (2019). http://doi.org/10.1016/J.SCITOTENV.2019.135534
Abstract: As real-life experimental data on natural ventilation of atmospheric pollution levels in urban street canyons is still scarce and has proven to be complex, this study, experimentally evaluated the impact of an urban street canyon opening on local atmospheric pollution levels, during a 2-week field campaign in a typical urban street canyon in Antwerp, Belgium. Besides following up on atmospheric particulate matter (PM), ultrafine particles (UFPs) and black carbon (BC) levels, the magneto-chemical PM10 composition was quantified to identify contributions of specific elements in enclosed versus open street canyon sections. Results indicated no higher overall PM, UFP and BC concentrations at the enclosed site compared to the open site, but significant day-to-day variability between both monitoring locations, depending on the experienced wind conditions. On days with oblique wind regimes (4 out of 14), natural ventilation was observed at the open location while higher element contributions of Ca, Fe, Co, Ni, Cu, Zn and Sr were exhibited at the enclosed location. Magnetic properties correlated with the PM10 filter loading, and elemental content of Fe, Cr, Mn and Ti. Magnetic bivariate ratios identified finel-grained magnetite carriers with grain sizes below 0.1 μm, indicating similar magnetic source contributions at both monitoring locations. Our holistic approach, combining atmospheric monitoring with magneto-chemical PM characterization has shown the complex impact of real-life wind flow regimes, different source contributions and local traffic dynamics on the resulting pollutant concentrations and contribute to a better understanding on the urban ventilation processes of atmospheric pollution.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Sustainable Energy, Air and Water Technology (DuEL)
Impact Factor: 4.9
DOI: 10.1016/J.SCITOTENV.2019.135534
|
|
|
“Implementation of an expert system for the qualitative interpretation of x-ray-fluorescence spectra”. Janssens K, van Espen P, Analytica chimica acta 184, 117 (1986). http://doi.org/10.1016/S0003-2670(00)86475-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/S0003-2670(00)86475-2
|
|
|
“Increased accuracy in the automated interpretation of large epma data sets by the use of an expert system”. Janssens K, Vanborm W, van Espen P, Journal of research of the National Bureau of Standards (1934) 93, 260 (1988). http://doi.org/10.6028/JRES.093.037
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.6028/JRES.093.037
|
|
|
“Interpretation and use of inter-element correlation graphs obtained by scanning X-ray fluorescence micro-beam spectrometry from individual particles: part 1: theory”. Somogyi A, Janssens K, Vincze L, Vekemans B, Rindby A, Adams F, Spectrochimica acta: part B : atomic spectroscopy 55, 75 (2000). http://doi.org/10.1016/S0584-8547(99)00172-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(99)00172-X
|
|
|
“Interpretation and use of inter-element correlation graphs obtained by scanning X-ray fluorescence micro-beam spectrometry from individual particles: part 2: application”. Somogyi A, Janssens K, Vincze L, Vekemans B, Rindby A, Adams F, Spectrochimica acta: part B : atomic spectroscopy 55, 1039 (2000). http://doi.org/10.1016/S0584-8547(00)00220-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(00)00220-2
|
|
|
“Interpretation of cappilary generated spatial and angular distribution of X-rays: theoretical modeling and experimental verification using the European Synchrotron Radiation Facility Optical Beamline”. Vincze L, Janssens K, Adams F, Engström P, Rindby A, The review of scientific instruments 69, 3494 (1998). http://doi.org/10.1063/1.1149127
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.515
DOI: 10.1063/1.1149127
|
|
|
“Localised and non-destructive analysis of metallic artefacts from ancient Egypt by means of a compact μ-XRF instrument”. Vittiglio G, Janssens K, Adams F, Oost A, Spectrochimica acta: part B : atomic spectroscopy 54, 1697 (1999). http://doi.org/10.1016/S0584-8547(99)00100-7
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(99)00100-7
|
|
|
“Micro and surface analysis in archaeology”. Adams F, Adriaens A, Aerts A, de Raedt I, Janssens K, Schalm O, Journal of analytical atomic spectrometry 12, 257 (1997). http://doi.org/10.1039/A606091I
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
DOI: 10.1039/A606091I
|
|
|
“Micro-distribution of heavy elements in highly inhomogeneous particles generated from μ-beam XRF/XRD analysis”. Rindby A, Engström P, Janssens K, Osán J, Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms 124, 591 (1997)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.109
|
|
|
“Micro-XANES determination of ferric iron and its application in thermobarometry”. Schmid R, Wilke M, Ober R, Dong S, Janssens K, Falkenberg G, Franz L, Gaab A, Lithos 70, 381 (2003). http://doi.org/10.1016/S0024-4937(03)00107-5
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0024-4937(03)00107-5
|
|
|
“A micro XRF spectrometer based on rotating anode generator and capillary optics”. Janssens K, Vekemans B, Vincze L, Adams F, Rindby A, Spectrochimica acta: part B : atomic spectroscopy 51, 1661 (1996)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Microscopic X-ray fluorescence analysis”. Janssens K, Vincze L, Rubio J, Bernasconi G, Adams F, Journal of analytical atomic spectrometry 9, 151 (1994). http://doi.org/10.1039/JA9940900151
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/JA9940900151
|
|
|
“Microscopical X-ray fluorescence analysis and related methods with laboratory and synchrotron radiation sources”. Adams F, Janssens K, Snigirev A, Journal of analytical atomic spectrometry 13, 319 (1998). http://doi.org/10.1039/A707100K
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
DOI: 10.1039/A707100K
|
|
|
“Modeling of photon scattering at high X-ray energies : experiment versus simulation”. Vincze L, Vekemans B, Janssens K, Adams F, Journal of analytical atomic spectrometry
T2 –, 15th International Congress on X-Ray Optics and Microanalysis (ICXOM), AUG 24-27, 1998, ANTWERP, BELGIUM 14, 529 (1999). http://doi.org/10.1039/A808040B
Abstract: The use of a detailed Monte Carlo simulation code for X-ray fluorescence spectrometers is demonstrated for calculating the outcome of X-ray scattering experiments in the incident energy range 40-80 keV. The code was validated by comparisons of experimental and simulated spectral distributions in the case of thick, homogeneous samples in which multiple photon scattering occurs with high probability. The experimental spectral distributions were collected at beamline BW5 of HASYLAB, Germany, where a highly energetic, monochromatic synchrotron beam is available. With respect to heterogeneous samples, the code was employed to evaluate the use of Rayleigh and Compton scatter signals for obtaining three dimensional information on the sample dark matrix composition.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
DOI: 10.1039/A808040B
|
|
|
“Monte Carlo simulation of conventional and synchrotron energy-dispersive X-ray spectrometers”. Janssens K, Vincze L, van Espen P, Adams F, X-ray spectrometry 22, 234 (1993). http://doi.org/10.1002/XRS.1300220412
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300220412
|
|
|
“Monte Carlo simulation of X-ray fluorescence spectra: part 4: photon scattering at high X-ray energies”. Vincze L, Janssens K, Vekemans B, Adams F, Spectrochimica acta: part B : atomic spectroscopy , 1711 (1999). http://doi.org/10.1016/S0584-8547(99)00094-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(99)00094-4
|
|
|
“Multianalytical study of patina formed on archaeological metal objects from Bliesbruck-Reinheim”. Wadsak M, Constantinides I, Vittiglio G, Adriaens A, Janssens K, Schreiner M, Adams FC, Brunella P, Wuttmann M, Microchimica acta 133, 159 (2000). http://doi.org/10.1007/S006040070086
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.58
DOI: 10.1007/S006040070086
|
|
|
“The non-destructive determination of REE in fossilized bone using synchrotron radiation induced K-line X-ray microfluorescence analysis”. Janssens K, Vincze L, Vekemans B, Williams CT, Radtke M, Haller M, Knöchel A, Fresenius' journal of analytical chemistry 363, 413 (1999). http://doi.org/10.1007/S002160051212
Abstract: The sensitivity and applicability of the synchrotron radiation induced X-ray microfluorescence (mu-SRXRF) spectrometer at the Hamburg synchrotron laboratory Hasylab for the determination of the distribution of trace concentrations of rare-earth elements (REE) in fossilized bone are discussed and critically compared to those of other trace analytical methods such as instrumental neutron activation analysis (INAA) and LAMP-ICPMS (laser ablation microprobe inductively-coupled plasma mass spectrometry). Measurements were carried out on two bone samples from contrasting terrestrial depositional environments at Olduvai Gorge (Tanzania). Results indicate that the microdistribution of the REE in these biological materials is not homogeneous and that the relative abundance of these elements can provide information on the palaeoenvironment during the fossilization process. The heterogeneous distribution of the REE can be determined in a quantitative and completely non-destructive manner provided the concentrations of individual REE are above 10 mu g/g.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S002160051212
|
|
|
“Optics for X-ray microfluorescence to be used at the European synchrotron radiation facility”. Vincze L, Janssens K, Adams F, Advances in X-ray analysis 37, 553 (1994)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Oxidation states of uranium in DU particles from Kosovo”. Salbu B, Janssens K, Lind OC, Proost K, Danesi PR, Journal of environmental radioactivity 64, 167 (2003). http://doi.org/10.1016/S0265-931X(02)00047-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.31
DOI: 10.1016/S0265-931X(02)00047-4
|
|
|
“PC-MCA : a software package for the acquisition and processing of spectral data”. Janssens K, Nobels J, van Espen P, Chemometrics and intelligent laboratory systems 3, 335 (1988). http://doi.org/10.1016/0169-7439(88)80033-9
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0169-7439(88)80033-9
|
|
|
“Prediction of the optical characteristics and analytical qualities of an X-ray fluorescence microprobe at the European Synchrotron Radiation Facility (Grenoble)”. van Langevelde F, Janssens KH, Adams FC, Vis RD, Nuclear instruments and methods in physics research : A: accelerators, spectrometers, detectors and associated equipment 317, 383 (1992). http://doi.org/10.1016/0168-9002(92)90632-E
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0168-9002(92)90632-E
|
|
|
“The preparation and preliminary characterisation of eight geological MPI-DING reference glasses for in-site microanalysis”. Jochum KP, Dingwell DB, Rocholl A, Janssens K, Vincze L, et al, Geostandards newsletter 24, 87 (2000). http://doi.org/10.1111/J.1751-908X.2000.TB00590.X
Abstract: Eight silicate glasses were prepared by directly fusing and stirring 50-100 g each of basalt, andesite, komatiite, peridotite, rhyolite, and quartz-diorite. These are referred to as MPI-DING glasses and were made for the purpose of providing reference materials for geochemical, in-situ microanalytical work. Results from various analytical techniques indicate that individual glass fragments are well homogenised with respect to major and trace elements at the mu m to mm scale. Heterogeneities due to quench crystallisation of olivine have been observed in small and limited areas of the two komatiitic glasses. In order to obtain concentration values for as many elements as possible, the glasses were analysed by a variety of bulk and microanalytical methods in a number of laboratories. From the analytical data, preliminary reference values for more than sixty elements were calculated. The analytical uncertainties of most elements are estimated to be between 1% and 10%.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1111/J.1751-908X.2000.TB00590.X
|
|