|
“Elemental abundance variation with particle-size in north florida aerosols”. Johansson TB, Van Grieken RE, Winchester JW, Journal of geophysical research 81, 1039 (1976). http://doi.org/10.1029/JC081I006P01039
Abstract: A nonurban base line has been established for nine trace element constituents of aerosol particles as a function of particle size at ground level sampling stations in north Florida up to 50 km from the Gulf of Mexico. The particle size range 0.25- to >4-μm aerodynamic diameter was investigated by cascade impactor sampling and elemental analysis by proton-induced X ray emission. By using a strategy of sampling at urban, forest, and coastal locations and by choosing approximately 48-hour sample averaging intervals the potential dependence of the base line levels both on local pollution and natural sources and on local particle size specific aerosol removal processes could be evaluated. It is found that elements contained in the largest particles, especially those of >4 μm, display the greatest degree of average concentration difference between sites, a result suggesting short atmospheric residence times and the importance of local dispersion sources and atmospheric cleansing processes in regulating the particle concentrations in air. Elements contained in particles of <2-μm diameter show little average concentration difference between sites unless they are influenced by local pollution sources, a finding suggesting that their concentrations in air are regulated by large-scale sources and transport processes. Sulfur in the smallest particles shows a marked constancy of concentration, but it may be modified in the largest particle size ranges in relation to proximity to the seacoast. No evidence is found for dependence of particulate sulfur concentrations on local pollution sources. K, Ca, Ti, Fe, and Zn appear to be regulated in the main by terrestrial source processes, and Cl by marine source processes, but Br and Pb appear to be accounted for adequately by assuming automotive fuel combustion as their major source. Limited data obtained for V indicate that it may vary considerably with fluctuations in aerosol transport from oil-fired electric power plant sources in the region. Limited additional data also suggest that Mn is derived from sources of natural terrestrial composition. In view of these findings, certain criteria may be set for the design of a meaningful nonurban aerosol monitoring network.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1029/JC081I006P01039
|
|
|
Rahemi V (2018) Electrosensing applications by using titania as a support for bio(inspired) molecules. 133 p
Keywords: Doctoral thesis; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Electropolymerized o-phenylenediamine on graphite promoting the electrochemical detection of nafcillin”. Bottari F, Moro G, Sleegers N, Florea A, Cowen T, Piletsky S, van Nuijs ALN, De Wael K, Electroanalysis 32, 135 (2019). http://doi.org/10.1002/ELAN.201900397
Abstract: By combining molecular modelling and electrochemistry we envision the creation of modified electrodes tailored for a more sensitive and selective detection of a single analyte. In this study we report on a graphite screen printed electrode modified with electropolymerized o-phenylenediamine, selected by rational design, which promotes the detection of nafcillin (NAF), an antibiotic. Parameters such as monomer concentration, pH and number of electropolymerization cycles were optimized to obtain the highest current signal for the target upon amperometric detection. NAF identification was based on the redox process at +1.1 V (vs pseudo Ag), ascribed to the oxidation of the C-7 side chain. With the optimized modification protocol, a two-fold increase in nafcillin signal could be obtained: the calibration plot in 0.1 M Britton-Robinson buffer pH 4 showed a limit of detection of 80 nM with improved sensitivity and reproducibility (RSD<5 %) compared to the detection at non-modified electrodes.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre
Impact Factor: 2.851
Times cited: 1
DOI: 10.1002/ELAN.201900397
|
|
|
“Electron probe X-ray microanalysis for the assessment of homogeneity of candidate reference materials at the nanogram level”. Hoornaert S, Treiger B, Valkovic V, Van Grieken R, Microchimica acta 128, 207 (1998). http://doi.org/10.1007/BF01243051
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF01243051
|
|
|
“Electron probe X-ray microanalysis for the assessment of homogeneity of candidate reference materials at the nanogram level”. Hoornaert S, Treiger B, Van Grieken R, Valkovic V page 29 (1996).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Electron probe micro-analysis and laser microprobe mass analysis of material, leached from a limestone cathedral”. Leysen LA, De Waele JK, Roekens EJ, Van Grieken RE, Scanning microscopy 1, 1617 (1987)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Electron microprobe observations of recrystallization affecting PIXE-analysis of marine aerosol deposits”. Storms H, Van Dyck P, Van Grieken R, Maenhaut W, Journal of trace and microprobe techniques 2, 103 (1985)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Electron microprobe characterization of individual aerosol particles collected by aircraft above the Southern Bight of the North Sea”. Rojas CM, Van Grieken RE, Atmospheric environment : an international journal 26a, 1231 (1992). http://doi.org/10.1016/0960-1686(92)90384-W
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0960-1686(92)90384-W
|
|
|
“Electron microprobe analysis of suspended matter in the Angola Basin”. Bernard P, Eisma D, Van Grieken R, Journal of sea research 41, 19 (1999). http://doi.org/10.1016/S1385-1101(98)00043-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S1385-1101(98)00043-4
|
|
|
“Electron energy-loss spectroscopy and its application to individual particle analysis”. Xhoffer C, Jacob W, Van Grieken R, Broekaert JAC, Buseck P, (1992)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Electrodeposition of gold nanoparticles on boron doped diamond electrodes for the enhanced reduction of small organic molecules”. Bottari F, De Wael K, Journal of electroanalytical chemistry : an international journal devoted to all aspects of electrode kynetics, interfacial structure, properties of electrolytes, colloid and biological electrochemistry. 801, 521 (2017). http://doi.org/10.1016/J.JELECHEM.2017.07.053
Abstract: The performance of gold nanoparticles electrodeposited on boron doped diamond (BDD) electrodes was investigated in respect to the reduction of chloramphenicol (CAP), an antibiotic of the phenicols family. The chosen deposition protocol, three nucleation-growing pulses, shows a remarkable surface coverage, with an even distribution of average-sized gold particles (~ 50 nm), and it was proven capable of generating a three-fold increase in the CAP reduction current. A calibration plot for CAP detection was obtained in the micromolar range (535 μM) with good correlation coefficient (0.9959) and an improved sensitivity of 0.053 μA μM− 1 mm− 2 compared to the electrochemistry of CAP at a bare BDD electrode.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.012
Times cited: 4
DOI: 10.1016/J.JELECHEM.2017.07.053
|
|
|
“Electrochemistry of intact versus degraded cephalosporin antibiotics facilitated by LC–MS analysis”. Sleegers N, van Nuijs ALN, van den Berg M, De Wael K, Analytical Chemistry 93, 2394 (2021). http://doi.org/10.1021/ACS.ANALCHEM.0C04286
Abstract: The electrochemical detection of cephalosporins is a promising approach for the monitoring of cephalosporin levels in process waters. However, this class of antibiotics, like penicillins, is composed of chemically active molecules and susceptible to hydrolysis and aminolysis of the four membered β-lactam ring present. In order to develop a smart monitoring strategy for cephalosporins, the influence of degradation (hydrolysis and aminolysis) on the electrochemical fingerprint has to be taken into account. Therefore, an investigation was carried out to understand the changes of the voltammetric fingerprints upon acidic and alkaline degradation. Changes in fingerprints were correlated to the degradation pathways through the combination of square wave voltammetry and liquid chromatography quadrupole time-of-flight analysis. The characteristic electrochemical signals of the β-lactam ring disappeared upon hydrolysis. Additional oxidation signals that appeared after degradation were elucidated and linked to different degradation products, and therefore, enrich the voltammetric fingerprints with information of the state of the cephalosporins. The applicability of the electrochemical monitoring system was explored by the analysis of the intact and degraded industrial process waters containing the key intermediate 7-aminodeacetoxycephalosporanic acid (7-ADCA). Clearly, the intact process samples exhibited the expected core signals of 7-ADCA and could be quantified, while the degraded samples only showed the newly formed degradation products.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre
Impact Factor: 6.32
DOI: 10.1021/ACS.ANALCHEM.0C04286
|
|
|
“Electrochemical strategies for the detection of forensic drugs”. Florea A, De Jong M, De Wael K, Current opinion in electrochemistry 11, 34 (2018). http://doi.org/10.1016/J.COELEC.2018.06.014
Abstract: Illicit drugs consumption and trafficking is spread worldwide and remains an increasing challenge for local authorities. Forensic drugs and their metabolites are released into wastewaters due to human excretion after illegal consumption of drugs and occasionally due to disposal of clandestine laboratory wastes into sewage systems, being recently classified as the latest group of emerging pollutants. Hence, it is essential to have efficient and accurate methods to detect these type of compounds in seized street samples, biological fluids and wastewaters in order to reduce and prevent trafficking and consumption and negative effects on aquatic systems. Electrochemical strategies offer a fast, portable, low-cost and accurate alternative to chromatographic and spectrometric methods, for the analysis of forensic drugs and metabolites in different matrices. Recent electrochemical strategies applied to the detection of illicit drugs in wastewaters, biological fluids and street samples are presented in this review, together with the impact of drug consumption on the environment.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 7
DOI: 10.1016/J.COELEC.2018.06.014
|
|
|
“Electrochemical strategies for adulterated heroin samples”. Florea A, Schram J, De Jong M, Eliaerts J, Van Durme F, Kaur B, Samyn N, De Wael K, Analytical chemistry 91, 7920 (2019). http://doi.org/10.1021/ACS.ANALCHEM.9B01796
Abstract: Electrochemical strategies to selectively detect heroin in street samples without the use of complicated electrode modifications were developed for the first time. For this purpose, heroin, mixing agents (adulterants, cutting agent, and impurities), and their binary mixtures were subjected to square wave voltammetry measurements at bare graphite electrodes at pH 7.0 and pH 12.0, in order to elucidate the unique electrochemical fingerprint of heroin and mixing agents as well as possible interferences or reciprocal influences. Adjusting the pH from pH 7.0 to pH 12.0 allowed a more accurate detection of heroin in the presence of most common mixing agents. Furthermore, the benefit of introducing a preconditioning step prior to running square wave voltammetry on the electrochemical fingerprint enrichment was explored. Mixtures of heroin with other drugs (cocaine, 3,4-methylenedioxymethamphetamine, and morphine) were also tested to explore the possibility of their discrimination and simultaneous detection. The feasibility of the proposed electrochemical strategies was tested on realistic heroin street samples from forensic cases, showing promising results for fast, on-site detection tools of drugs of abuse.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 2
DOI: 10.1021/ACS.ANALCHEM.9B01796
|
|
|
“Electrochemical sensing of phenicol antibiotics at gold”. Pilehvar S, Dardenne F, Blust R, De Wael K, International journal of electrochemical science 7, 5000 (2012)
Abstract: Phenicols are an effective and a broad spectrum class of antibiotics which has lost favour due to their side effects on human health. A rapid and sensitive electrochemical detection system is developed for the simultaneous detection of chloramphenicol (CAP), thiamphenicol (TAP) and florfenicol (FF). The electrochemical behaviour of CAP in the presence of its derivatives was investigated by cyclic voltammetry (CV) and square wave voltammetry (SWV). At a gold electrode, CAP gives rise to a sensitive cathodic peak at −0.68V (versus SCE) in a tris buffer solution (pH 7.6). This behavior gives us the opportunity to introduce a method for sensing CAP electrochemically in the presence of its derivatives. Calibration graphs were linear in the 2.5-7.4 μmol L-1 concentration range. Deviations from linearity were observed for higher concentrations and this was interpreted to be due to kinetic limitation caused by the saturation of CAP and its reduction products onto the gold electrode surface. A limit of detection of 1 μmol L-1 was found.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.469
|
|
|
“Electrochemical reduction of nalidixic acid at glassy carbon electrodemodified with multi-walled carbon nanotubes”. Patiño Y, Pilehvar S, Díaz E, Ordóñez S, De Wael K, Journal of hazardous materials 323, 621 (2017). http://doi.org/10.1016/J.JHAZMAT.2016.10.023
Abstract: The aqueous phase electrochemical degradation of nalidixic acid (NAL) is studied in this work, using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) as instrumental techniques. The promotional effect of multi-walled carbon nanotubes (MWCNT) on the the performance of glassy carbon electrodes is demonstrated, being observed that these materials catalyze the NAL reduction. The effect of surface functional groups on MWCNT −MWCNT-COOH and MWCNT-NH2was also studied. The modification of glassy carbon electrode (GCE) with MWCNT leads to an improved performance for NAL reduction following the order of MWCNT > MWCNT-NH2 > MWCNT-COOH. The best behavior at MWCNT-GCE is mainly due to both the increased electrode active area and the enhanced MWCNT adsorption properties. The NAL degradation was carried out under optimal conditions (pH = 5.0, deposition time = 20 s and volume of MWCNT = 10 μL) using MWCNT-GCE obtaining an irreversible reduction of NAL to less toxic products. Paramaters as the number of DPV cycles and the volume/area (V/A) ratio were optimized for maximize pollutant degradation. It was observed that after 15 DPV scans and V/A = 8, a complete reduction was obtained, obtaining two sub-products identified by liquid chromatography-mass spectrometry (LCMS).
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.065
Times cited: 4
DOI: 10.1016/J.JHAZMAT.2016.10.023
|
|
|
“Electrochemical profiling and liquid chromatography–mass spectrometry characterization of synthetic cathinones : from methodology to detection in forensic samples”. Schram J, Parrilla M, Sleegers N, Van Durme F, van den Berg J, van Nuijs ALN, De Wael K, Drug Testing And Analysis 13, 1282 (2021). http://doi.org/10.1002/DTA.3018
Abstract: The emergence of new psychoactive drugs in the market demands rapid and accurate tools for the on‐site classification of illegal and legal compounds with similar structures. Herein, a novel method for the classification of synthetic cathinones (SC) is presented based on their electrochemical profile. First, the electrochemical profile of five common SC (i.e., mephedrone, ethcathinone, methylone, butylone and 4‐chloro‐alpha‐pyrrolidinovalerophenone) is collected to build calibration curves using square wave voltammetry on graphite screen‐printed electrodes (SPE). Second, the elucidation of the oxidation pathways, obtained by liquid chromatography‐high resolution mass spectrometry, allows the pairing of the oxidation products to the SC electrochemical profile, providing a selective and robust classification. Additionally, the effect of common adulterants and illicit drugs on the electrochemical profile of the SC is explored. Interestingly, a cathodic pretreatment of the SPE allows the selective detection of each SC in presence of electroactive adulterants. Finally, the electrochemical approach is validated with gas‐chromatography‐mass spectrometry by analyzing 26 confiscated samples from seizures and illegal webshops. Overall, the electrochemical method exhibits a successful classification of SC including structural derivatives, a crucial attribute in an ever‐diversifying drug market.
Keywords: A1 Journal article; Pharmacology. Therapy; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre
Impact Factor: 3.469
DOI: 10.1002/DTA.3018
|
|
|
“Electrochemical photodegradation study of semiconductor pigments : influence of environmental parameters”. Anaf W, Trashin S, Schalm O, van Dorp D, Janssens K, De Wael K, Analytical chemistry 86, 9742 (2014). http://doi.org/10.1021/AC502303Z
Abstract: Chemical transformations in paintings often induce discolorations, disturbing the appearance of the image. For an appropriate conservation of such valuable and irreplaceable heritage objects, it is important to have a good know-how on the degradation processes of the (historical) materials: which pigments have been discolored, what are the responsible processes, and which (environmental) conditions have the highest impact on the pigment degradation and should be mitigated. Pigment degradation is already widely studied, either by analyzing historical samples or by accelerated weathering experiments on dummies. However, in historic samples several processes may have taken place, increasing the complexity of the current state, while aging experiments are time-consuming due to the often extended aging period. An alternative method is proposed for a fast monitoring of degradation processes of semiconductor pigments, using an electrochemical setup mimicking the real environment and allowing the identification of harmful environmental parameters for each pigment. Examples are given for the pigments cadmium yellow (CdS) and vermilion (α-HgS).
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
Impact Factor: 6.32
Times cited: 18
DOI: 10.1021/AC502303Z
|
|
|
“Electrochemical identification of hazardous phenols and their complex mixtures in real samples using unmodified screen-printed electrodes”. Barich H, Cánovas R, De Wael K, Journal of electroanalytical chemistry : an international journal devoted to all aspects of electrode kynetics, interfacial structure, properties of electrolytes, colloid and biological electrochemistry. 904, 115878 (2022). http://doi.org/10.1016/J.JELECHEM.2021.115878
Abstract: The electrochemical behavior of some of the most relevant endocrine-disrupting phenols using unmodified carbon screen-printed electrodes (SPEs) is described for the first time. Experiments were made to assess the electrochemical behavior of phenol (PHOH), pentachlorophenol (PCP), 4-tert octylphenol (OP) and bisphenol A (BPA) and their determination in the most favorable conditions, using voltammetric methods such as cyclic voltammetry (CV), linear sweep voltammetry (LSV) and square wave voltammetry (SWV) in Britton Robinson (BR) buffer. Further, the usefulness of the electrochemical approach was validated with real samples from a local river and was compared to commercial phenols test kit, which is commonly used for on-site screening in industrial streams and wastewaters. Finally, the approach was compared with a lab-bench standard method using real samples, i.e., high-performance liquid chromatography with a photodiode array detector (HPLC-DAD).
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 4.5
DOI: 10.1016/J.JELECHEM.2021.115878
|
|
|
“Electrochemical fingerprints of illicit drugs on graphene and multi-walled carbon nanotubes”. Dragan A-M, Truta FM, Tertis M, Florea A, Schram J, Cernat A, Feier B, De Wael K, Cristea C, Oprean R, Frontiers In Chemistry 9, 641147 (2021). http://doi.org/10.3389/FCHEM.2021.641147
Abstract: Illicit drugs use and abuse remains an increasing challenge for worldwide authorities and, therefore, it is important to have accurate methods to detect them in seized samples, biological fluids and wastewaters. They are recently classified as the latest group of emerging pollutants as their consumption increased tremendously in recent years. Nanomaterials have gained much attention over the last decade in the development of sensors for a myriad of applications. The applicability of these nanomaterials, functionalized or not, significantly increases and it is therefore highly suitable for use in the detection of illicit drugs. We have assessed the suitability of various nanoplatforms, such as graphene (GPH), multi-walled carbon nanotubes (MWCNTs), gold nanoparticles (AuNPs) and platinum nanoparticles (PtNPs) for the electrochemical detection of illicit drugs. GPH and MWCNTs were chosen as the most suitable platforms and cocaine, 3,4-methylendioxymethamfetamine (MDMA), 3-methylmethcathinone (MMC) and alpha-pyrrolidinovalerophenone (PVP) were tested. Due to the hydrophobicity of the nanomaterials-based platforms which led to low signals, two strategies were followed namely, pretreatment of the electrodes in sulfuric acid by cyclic voltammetry and addition of Tween 20 to the detection buffer. Both strategies led to an increase in the oxidation signal of illicit drugs. Binary mixtures of illicit drugs with common adulterants found in street samples were also investigated. The proposed strategies allowed the sensitive detection of illicit drugs in the presence of most adulterants. The suitability of the proposed sensors for the detection of illicit drugs in spiked wastewaters was finally assessed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.994
DOI: 10.3389/FCHEM.2021.641147
|
|
|
“Electrochemical fingerprint of street samples for fast on-site screening of cocaine in seized drug powders”. De Jong M, Sleegers N, Kim J, Van Durme F, Samyn N, Wang J, De Wael K, Chemical science , 1 (2016). http://doi.org/10.1039/C5SC04309C
Abstract: We report on a wearable fingertip sensor for on-the-spot identification of cocaine and its cutting agents in street samples. Traditionally, on-site screening is performed by means of colour tests which are difficult to interpret and lack selectivity. By presenting the distinct voltammetric response of cocaine, cutting agents, binary mixtures of cocaine and street samples in solution and powder street samples, we were able to elucidate the electrochemical fingerprint of all these compounds. The new electrochemical concept holds considerable promise as an on-site screening method.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 8.668
Times cited: 37
DOI: 10.1039/C5SC04309C
|
|
|
“Electrochemical evidence for neuroglobin activity on NO at physiological concentrations”. Trashin S, De Jong M, Luyckx E, Dewilde S, De Wael K, Journal of biological chemistry 291, 18959 (2016). http://doi.org/10.1074/JBC.M116.730176
Abstract: The true function of neuroglobin (Ngb) and, particularly, human Ngb (NGB) has been under debate since its discovery 15 years ago. It has been expected to play a role in oxygen binding/supply, but a variety of other functions have been put forward, including NO dioxygenase activity. However, in vitro studies that could unravel these potential roles have been hampered by the lack of an Ngb-specific reductase. In this work, we used electrochemical measurements to investigate the role of an intermittent internal disulfide bridge in determining NO oxidation kinetics at physiological NO concentrations. The use of a polarized electrode to efficiently interconvert the ferric (Fe3+) and ferrous (Fe2+) forms of an immobilized NGB showed that the disulfide bridge both defines the kinetics of NO dioxygenase activity and regulates appearance of the free ferrous deoxy-NGB, which is the redox active form of the protein in contrast to oxy-NGB. Our studies further identified a role for the distal histidine, interacting with the hexacoordinated iron atom of the heme, in oxidation kinetics. These findings may be relevant in vivo, for example in blocking apoptosis by reduction of ferric cytochrome c, and gentle tuning of NO concentration in the tissues.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.125
Times cited: 11
DOI: 10.1074/JBC.M116.730176
|
|
|
“Electrochemical determination of hydrogen peroxide with cytochrome c peroxidase and horse heart cytochrome c entrapped in a gelatin hydrogel”. De Wael K, Bashir Q, van Vlierberghe S, Dubruel P, Heering HA, Adriaens A, Bioelectrochemistry: an international journal devoted to electrochemical aspects of biology and biological aspects of electrochemistry 83, 15 (2012). http://doi.org/10.1016/J.BIOELECHEM.2011.07.001
Abstract: A novel and versatile method, based on a membrane-free enzyme electrode in which both the enzyme and a mediator protein are entrapped in a gelatine hydrogel was developed for the fabrication of biosensors. As a proof of principle, we prepared a hydrogen peroxide biosensor by successfully entrapping both horse heart cytochrome c (HHC) and Saccharomyces cerevisae cytochrome c peroxidase (CCP) in a gelatin matrix which is immobilized on a gold electrode. This electrode was first pretreated with 6-mercaptohexanol. The biosensor displayed a rapid response and an expanded linear response range from 0 to 0.3 mM (R = 0.987) with a detection limit of 1 × 10− 5 M in a HEPES buffer solution (pH 7.0). This method of encapsulation is now further investigated for industrial biosensor applications.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.346
Times cited: 31
DOI: 10.1016/J.BIOELECHEM.2011.07.001
|
|
|
“Electrochemical detection of Toxocara canis excretory-secretory antigens in children from rural communities in Esmeraldas Province, Ecuador : association between active infection and high eosinophilia”. Morales-Yánez F, Trashin S, Sariego I, Roucher C, Paredis L, Chico M, De Wael K, Muyldermans S, Cooper P, Polman K, Parasites &, Vectors 13, 245 (2020). http://doi.org/10.1186/S13071-020-04113-2
Abstract: Background The diagnosis of active Toxocara canis infections in humans is challenging. Larval stages of T. canis do not replicate in human tissues and disease may result from infection with a single T. canis larva. Recently, we developed a nanobody-based electrochemical magnetosensor assay with superior sensitivity to detect T. canis excretory-secretory (TES) antigens. Here, we evaluate the performance of the assay in children from an Ecuadorian birth cohort that followed children to five years of age. Methods Samples were selected based on the presence of peripheral blood eosinophilia and relative eosinophil counts. The samples were analyzed by the nanobody-based electrochemical magnetosensor assay, which utilizes a bivalent biotinylated nanobody as capturing agent on the surface of streptavidin pre-coated paramagnetic beads. Detection was performed by a different nanobody chemically labelled with horseradish peroxidase. Results Of 87 samples tested, 33 (38%) scored positive for TES antigen recognition by the electrochemical magnetosensor assay. The average concentration of TES antigen in serum was 2.1 ng/ml (SD = 1.1). The positive result in the electrochemical assay was associated with eosinophilia > 19% (P = 0.001). Parasitological data were available for 57 samples. There was no significant association between positivity by the electrochemical assay and the presence of other soil-transmitted helminth infections. Conclusions Our nanobody-based electrochemical assay provides highly sensitive quantification of TES antigens in serum and has potential as a valuable tool for the diagnosis of active human toxocariasis.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.2
DOI: 10.1186/S13071-020-04113-2
|
|
|
“Electrochemical detection of MDMA and 2C-B in ecstasy tablets using a selectivity enhancement strategy by in-situ derivatization”. Van Echelpoel R, Kranenburg R, van Asten A, De Wael K, Forensic chemistry 27, 100383 (2022). http://doi.org/10.1016/J.FORC.2021.100383
Abstract: Forensic drug laboratories are confronted with increasing amounts of drugs and a demand for faster results that are directly available on-site. In addition, the drug market is getting more complex with hundreds of new psychoactive substances (NPS) entering the market in recent years. Rapid and on-scene presumptive drug testing therefore faces a shift from manual colorimetric tests towards approaches that can detect a wider range of components and process results automatically. Electrochemical detection offers these desired characteristics, making it a suitable candidate for on-site drug detection. In this study, a two-step electrochemical sensor is introduced for the detection of MDMA and 2C-B. Firstly, a direct electrochemical analysis was performed to detect MDMA. Validation experiments on over 70 substances revealed that 2C-B was the only frequently encountered drug that gave a false positive result for MDMA in this first analysis. A second step using in-situ derivatization was subsequently introduced. To this end, formaldehyde was used for N-methylation of 2C-B thereby enhancing its electrochemical profile. The enriched electrochemical fingerprint in the second step allowed for clear differentiation between MDMA and 2C-B. The applicability of this approach was demonstrated with 71 ecstasy tablets seized by the Amsterdam Police. The MDMA/2C-B sensor correctly identified all 39 MDMA-containing tablets and 10 out of 11 tablets containing 2C-B. Most notably, correct results were also obtained for dark colored tablets in which both spectroscopic analysis and colorimetric tests failed due to obscured signals.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 2.7
DOI: 10.1016/J.FORC.2021.100383
|
|
|
“Electrochemical deposition of a copper carboxylate layer on copper as potential corrosion inhibitor”. Elia A, De Wael K, Dowsett M, Adriaens A, Journal of solid state electrochemistry 16, 143 (2011). http://doi.org/10.1007/S10008-010-1283-6
Abstract: Carboxylic acids and sodium carboxylates are used to protect metals against aqueous and atmospheric corrosion. In this paper, we describe the application of a layer of copper carboxylate on the surface of a copper electrode by means of cyclic voltammetry technique and tests which measure the corresponding resistance to aqueous corrosion. Unlike the soaking process, which also forms a film on the surface, the use of cyclic voltammetry allows one to follow the deposition process of the copper carboxylates onto the electrode. The modified electrodes have been characterised with infrared spectroscopy. In addition, the corrosion resistance of the film has been investigated using polarisation resistance and Tafel plot measurements.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.316
Times cited: 8
DOI: 10.1007/S10008-010-1283-6
|
|
|
Blust RJP, Dardenne F, De Wael K, Nagels L, Van Camp G (2013) Electrochemical aptasensors with a gelatin B matrix : EP13175128
Abstract: An aptamer-based electrochemical sensor, wherein said aptamer is covalently bonded to or chemisorbed on an electrode, said aptamer forming a robust complex with a target molecule and is encapsulated by a gelatin B matrix; a method of manufacturing an aptamer-based electrochemical sensor for determining a concentration of a target molecule comprising the steps of: selecting an aptamer to form a robust complex with a target molecule using the SELEX procedure; synthesizing said aptamer; adsorbing said aptamer on or covalently coupling said aptamer with an electrode; and providing a gelatin B matrix for said aptamer on said electrode thereby realising said aptamer-based potentiometric or amperometric sensor; and the use of the aptamer-based electrochemical sensor produced according to the above method for the electrochemical determination of a concentration of 15 the target molecule.
Keywords: Patent; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Electrochemical and spectroelectrochemical studies of tert-butyl-substituted aluminum phthalocyanine”. Moiseeva EO, Trashin S, Korostei YS, Khan SU, Kosov AD, De Wael K, Dubinina TV, Tomilova LG, Polyhedron 200, 115136 (2021). http://doi.org/10.1016/J.POLY.2021.115136
Abstract: Tetra-tert-butylphthalocyanine aluminum (III) chloride was studied by voltammetric and potential-resolved spectroelectrochemical methods in a non-coordinating solvent o-dichlorobenzene. Five redox transitions were found including two oxidation waves at 0.18 and 0.90 V and three reduction waves at −1.28, −1.65, and −2.63 V vs. Fc+/Fc. Electrochemical reversibility of the first oxidation and reduction processes was assessed by using the diagnostic criteria of cyclic voltammetry. First comprehensive spectroelectrochemical characterization of oxidation of the aluminum phthalocyanine is reported. Moreover, potential-resolved spectroelectrochemical titration revealed strong influence of aggregation on the UV–vis spectra and the half-wave potentials of the first oxidation transition and disclosed the presence of the partially oxidized complex in the initial solution, which noticeably affected the spectrum of the neutral form.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.926
DOI: 10.1016/J.POLY.2021.115136
|
|
|
“Electrochemical Analysis of Speedball-like Polydrug Samples”. de Jong M, Florea A, Daems D, Van Loon J, Samyn N, De Wael K, Analyst (2020). http://doi.org/10.1039/D0AN01097A
Abstract: Increasing global production, trafficking and consumption of drugs of abuse cause an emerging threat to people’s health and safety. Electrochemical approaches have proven to be useful for on-site analysis of drugs of abuse. However, few attention has been focused on the analysis of polydrug samples, despite these samples causing severe health concerns, certainly when stimulants and depressants are combined, as is the case for Speedball, a mixture of cocaine and heroin. In this work, we provide solutions for the selective detection of cocaine (stimulant) in polydrug samples adulterated with heroin and codeine (depressants). The presence of either one of these compounds in cocaine street samples leads to an overlap with the cocaine signal in square-wave voltammetry measurements at unmodified carbon screen-printed electrodes, leading to inconclusive screening results in the field. The provided solutions to this problem consist of two parallel approaches: (i) cathodic pretreatment of the carbon screen-printed electrode surface prior to measurement in both alkaline and neutral conditions; (ii) electropolymerization of orthophenylenediamine on graphene modified carbon screen-printed electrodes prior to measurement in neutral conditions. Both strategies allow simultaneous detection of cocaine and heroin in speedball samples as well as simultaneous detection of cocaine and codeine. Implementing these strategies in portable devices holds great potential for significantly improved accuracy of on-site cocaine screening in polydrug samples.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Product development
Impact Factor: 4.2
DOI: 10.1039/D0AN01097A
|
|
|
“Electrochemical analysis of cocaine in real samples based on electrodeposited biomimetic affinity ligands”. Florea A, Cowen T, Piletsky S, De Wael K, The analyst 144, 4639 (2019). http://doi.org/10.1039/C9AN00618D
Abstract: A selective electrochemical sensor for direct detection of cocaine was developed based on molecularly imprinted polymers electropolymerized onto graphene-modified electrodes. Palladium nanoparticles were integrated in the sensing layer for the benefit of enhancing the communication between imprinted sites and electrode and improving their homogenous distribution. The molecularly imprinted polymer was synthesized by cyclic voltammetry using p-aminobenzoic acid as high affinity monomer selected by computational modeling, and cocaine as template molecule. Experimental parameters related to the electrochemical deposition of palladium nanoparticles, pH, composition of electropolymerization mixture, extraction and rebinding condition were studied and optimized. Under optimized conditions the oxidation peak current varied linearly with cocaine concentration in the range of 100-500 µM, with a detection limit of 50 µM (RSD 0.71%, n=3). The molecularly imprinted sensor was able to detect cocaine in saliva and river water with good recoveries after sample pretreatment and was successfully applied for screening real street samples for cocaine.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.885
Times cited: 3
DOI: 10.1039/C9AN00618D
|
|