|
“Influence of sample thickness, excitation energy and geometry on particle size effects in XRF”. Van Dyck P, Markowicz A, Van Grieken R, X-ray spectrometry 14, 183 (1985). http://doi.org/10.1002/XRS.1300140409
Abstract: Expressions are presented for calculating the matrix effect and the pure particle size effect in the XRF analysis of particulate samples with a discrete particle size. The equations are based on the absorption-weighted radiometric diameter concept. Two excitationdetection geometries are considered, with the angles between the sample plane and both the incident and emerging radiation being either 90° (π geometry) or 45° (π/2 geometry). Calculations were made for different sample loadings and exciting radiation energies. The influence of these parameters on the matrix and pure particle size effects is shown. From the results, it is possible to predict the performances of alternative experimental correction procedures for the particle size effect, involving dual measurements at different excitation energies or in different excitationdetection geometries.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300140409
|
|
|
“Individual particle characterization of Siberian aerosols by micro-PIXE and backscattering spectrometry”. van Malderen H, Hoornaert S, Injuk J, Przybylowicz WJ, Pineda CA, Prozesky VM, Van Grieken R, X-ray spectrometry 30, 320 (2001). http://doi.org/10.1002/XRS.505
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.505
|
|
|
“ID18F: a new micro-X-ray fluorescence end-station at the European Synchrotron Radiation Facility (ESRF): preliminary results”. Somogyi A, Drakopoulos M, Vincze L, Vekemans B, Camerani C, Janssens K, Snigirev A, Adams F, X-ray spectrometry 30, 242 (2001). http://doi.org/10.1002/XRS.494.ABS
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 76
DOI: 10.1002/XRS.494.ABS
|
|
|
“High-energy polarized-beam EDXRF for trace metal analysis of vegetation samples in environmental studies”. Marguí, E, Padilla R, Hidalgo M, Queralt I, Van Grieken R, X-ray spectrometry 35, 169 (2006). http://doi.org/10.1002/XRS.890
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.890
|
|
|
“Heterogeneity effects in direct XRF analysis of traces of heavy metals preconcentrated on polyurethane foam sorbents”. Török S, Braun T, Van Dyck P, Van Grieken R, X-ray spectrometry 15, 7 (1986). http://doi.org/10.1002/XRS.1300150104
Abstract: Trace amounts of heavy metals were preconcentrated on discs of polyurethane (PU) foam loaded with ammonium diethyldithiocarbamate (DDTC), to increase the sensitivity of XRF. Since the diameter of the cavities in the open-cell PU foams reaches 30300 μm, considerable heterogeneity effects might occur, which could reduce the accuracy of the method. The possible systematic error introduced by considering the sample to be homogeneous is calculated using the Berry et al. model. The calculations show that the underestimation of the absorption correction factor when considering the sample as being homogeneous is less than 2% for high-Z elements when the sample thickness is at least 2 mm. The detection limits are also around the minima for this thickness.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150104
|
|
|
“Heterogeneity effects in direct X-ray fluorescence analysis of hair”. Török S, Van Dyck P, Van Grieken R, X-ray spectrometry 13, 27 (1984). http://doi.org/10.1002/XRS.1300130106
Abstract: The methodology of direct hair analysis by energy-dispersive x-ray fluorescence was studied. The effect on the XRF result of having a non-homogeneous radial distribution of the analyte in a single hair strand and the macroscopic effects in a bundle of hairs were calculated to evaluate possible systematic errors. The detection limits were mapped as a function of the target thickness and surface fraction. It appeared that a 10 mg cm−2 sample thickness, i. e. a target with about four layers of hair strands, is recommended. The standard deviation of this simple direct analytical method is 619% for some important elements. Discrepancies with neutron activation analysis had a mean value of around 15%. About twelve elements can be determined simultaneously on a routine basis.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300130106
|
|
|
“Heavy metal analysis around Iskenderun Bay in Turkey”. Čevik U, Koz B, Makarovska Y, X-ray spectrometry 39, 202 (2010). http://doi.org/10.1002/XRS.1250
Abstract: The heavy metal analysis around Iskenderun Bay in Turkey was carried out using mosses, soils, mussels, and sediments. This region is one of the most industrial areas of Turkey, including iron-steel plants, beverage, liquefied petroleum gas (LPG) plants, and oil transfer docks. Energy dispersive X-ray fluorescence spectrometry (Epsilon 5, PANalytical, Almelo, The Netherlands) was used to analyze all samples. V, Cr, Mn, Fe, Ni, Cu, Zn, As, and Pb elements were observed in all samples studied. Although Ce was detected in some mosses and soils, Sn was detected only in some moss samples. Pb concentrations in the moss samples are higher than the soil, the mussel, and the sediment samples. This can be attributed to the mosses that absorb heavy metals such as Pb easily from the air. As the aim of this study was to analyze heavy metals, the evaluation of these elements with their potential hazards for ecology and humans is briefly discussed
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1250
|
|
|
“Grazing-exit electron probe x-ray microanalysis of light elements in particles”. Spolnik Z, Tsuji K, Van Grieken R, X-ray spectrometry 33, 16 (2004). http://doi.org/10.1002/XRS.656
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.656
|
|
|
“Folding of aerosol loaded filters during X-ray fluorescence analysis”. Van Grieken RE, Adams FC, X-ray spectrometry 5, 61 (1976). http://doi.org/10.1002/XRS.1300050204
Abstract: Folding aerosol loaded filters in two with the loaded side inwards during the X-ray analysis not only reduces possible filter heterogeneity effects and improves sample protection, but also increases the sensitivity and renders filter paper absorption corrections simple and more accurate in many instances. It is shown that folding an aerosol loaded Whatman filter paper during Kα X-rays counting leads to an increased sensitivity for all elements up from calcium, scandium or titanium (depending on the sensitivity definition and on the aerosol load) and for all elements up from phosphorus, sulphur or chlorine in the case of the Nuclepore filter. Although the absorption by the filter, into which the aerosol penetrates to some extent, is always more important in the sandwich than in the usual geometry, the dependence of the absorption correction on the usually unknown average deposition depth is less pronounced. Assuming all the aerosol material to be collected at the very surface of the filter and hence being present in the centre of the sandwich to be analysed, leads to an extremely simple filter paper absorption correction which is less prone to uncertainties than more sophisticated corrections in the usual geometry requiring additional measurements. This is the case for all elements up from potassium on Whatman filters and up from phosphorus on Nuclepore filters.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300050204
|
|
|
“EXRS2022 : the 2022 edition of the European X-ray Spectrometry conference, held in Bruges, Belgium”. Janssens K, X-ray spectrometry 52, 276 (2023). http://doi.org/10.1002/XRS.3386
Keywords: Editorial; Antwerp X-ray Imaging and Spectroscopy (AXIS)
Impact Factor: 1.2
DOI: 10.1002/XRS.3386
|
|
|
“Evaluation of the ArmstrongBuseck correction for automated electron probe X-ray microanalysis of particles”. Storms HM, Janssens KH, Török SB, Van Grieken RE, X-ray spectrometry 18, 45 (1989). http://doi.org/10.1002/XRS.1300180203
Abstract: The ArmstrongBuseck correction for absorption effects in electron probe x-ray microanalysis of particles considers seven specific particle shapes, and for these geometries exact correction equations are used. This procedure implies that the analyst has to associate the particle to be analysed with a certain particle type; an arbitrary relative thickness is sometimes assumed. A theoretical study was made of this absorption correction as a function of the particle composition, type and thickness for micrometre-sized particles. It appears that a correct choice of the particle type is critical. However, when the analytical results are normalized to 100%, the differences between the models are much less pronounced, and it is justified to assume a spherical model in all cases.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300180203
|
|
|
“Evaluation of energy-dispersive x-ray spectra of low-Z elements from electron-probe microanalysis of individual particles”. Osán J, de Hoog J, van Espen P, Szalóki I, Ro C-U, Van Grieken R, X-ray spectrometry 30, 419 (2001). http://doi.org/10.1002/XRS.523
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.523
|
|
|
“Evaluation of an equation for bremsstrahlung background in electron-probe X-ray microanalysis of composite samples”. Markowicz A, Storms H, Van Grieken R, X-ray spectrometry 15, 131 (1986). http://doi.org/10.1002/XRS.1300150211
Abstract: A new equation for predicting the generated bremsstrahlung background intensity in electron-probe x-ray microanalysis has been verified experimentally. This equation is applicable to all bulk composite specimens and reduces to Kramers' equation for pure elements only. The experimental verification has been carried out for Al2O3, Fe2O3 and ZrO2 with radiation energies from 4.2 to 14.8 keV. The predicted bremsstrahlung intensities are in good agreement with the experimental data.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150211
|
|
|
“EPMA and µ-SRXRF analysis and TEM-based microstructure characterization of a set of Roman glass fragments”. Fredrickx P, de Ryck I, Janssens K, Schryvers D, Petit J-P, Döcking H, X-ray spectrometry 33, 326 (2004). http://doi.org/10.1002/xrs.734
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 13
DOI: 10.1002/xrs.734
|
|
|
“Energy-dispersive X-ray fluorescence in geochemical mapping”. Civici N, Van Grieken R, X-ray spectrometry 26, 147 (1997). http://doi.org/10.1002/(SICI)1097-4539(199707)26:4<147::AID-XRS193>3.0.CO;2-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/(SICI)1097-4539(199707)26:4<147::AID-XRS193>3.0.CO;2-X
|
|
|
“Energy-dispersive X-ray fluorescence analysis of geological materials in borax beads using Tertian's binary coefficient approach combined with internal standard addition”. Muia LM, Van Grieken R, X-ray spectrometry 20, 179 (1991)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Efficiency calibartion of energy-dispersive detectors for application in quantitative x- and γ-ray spectrometry”. Szalóki I, Szegedi S, Varga K, Braun M, Osán J, Van Grieken R, X-ray spectrometry 30, 49 (2001). http://doi.org/10.1002/XRS.467
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.467
|
|
|
“EDXRS study of aerosol composition variations in air masses crossing the North Sea”. Injuk J, van Malderen H, Van Grieken R, Swietlicki E, Knox JM, Schofield R, X-ray spectrometry 22, 220 (1993). http://doi.org/10.1002/XRS.1300220410
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300220410
|
|
|
“EDXRF determination of impurities in potassium dihydrogenphosphate single crystals and raw materials”. Belikov KN, Mikhailova LI, Spolnik ZM, Van Grieken R, X-ray spectrometry 35, 112 (2006). http://doi.org/10.1002/XRS.874
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.874
|
|
|
“Editorial: Award for best XRS referee during 2007-2008”. Van Grieken R, X-ray spectrometry 37, 571 (2008). http://doi.org/10.1002/XRS.1107
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1107
|
|
|
“Editorial : introducing Dr Markowicz as X-Ray Spectrometry's new associate editor for Europe”. Van Grieken R, X-ray spectrometry 42, 175 (2013). http://doi.org/10.1002/XRS.2447
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2447
|
|
|
“Editorial : award for best X-Ray Spectrometry referee during 2011-2012”. Van Grieken R, X-ray spectrometry 42, 3 (2013). http://doi.org/10.1002/XRS.2428
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2428
|
|
|
“Determination of sample thickness via scattered radiation in X-ray fluorescence spectrometry with filtered continuum excitation”. Araujo MF, van Espen P, Van Grieken R, X-ray spectrometry 19, 29 (1990). http://doi.org/10.1002/XRS.1300190107
Abstract: A semi-empirical approach is described for determining the mass per unit area of a sample being analysed. The method can be used to estimate the concentration of minor and trace elements in matrices containing a substantial amount of light elements. The procedure utilizes the coherently and incoherently scattered radiation induced in the sample by the filtered continuum radiation of a rhodium x-ray tube. The relationship between the intensity of the scattered radiation per unit mass and the average atomic number of the sample is established via calibration graphs, which can be applied for different x-ray tube voltages and for different primary beam filters. The overall procedure was validated by the analysis of several geological standards, deposited as thin slurries of unknown thickness either on Mylar foil or on Nuclepore filters.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300190107
|
|
|
“Determination of barium, lanthanum, cerium and neodymium in lateritic materials by various energy-dispersive X-ray fluorescence techniques and neutron activation analysis”. Labrecque JJ, Beusen JM, Van Grieken RE, X-ray spectrometry 15, 13 (1986). http://doi.org/10.1002/XRS.1300150105
Abstract: A comparison of four methods for the determination of barium, lanthanum, cerium and neodymium in lateritic materials from Brazil is presented. Three of the methods were based on x-ray fluorescence (XRF) spectroscopy: two by radioisotope excitation (Co-57 and Am-241) and one by secondary target XRF (a molybdenum target with a tungsten anode). The other method was based on neutron activation analysis employing both a Ge(Li) coaxial detector and a high-purity germanium detector. The results from these four methods were similar for lanthanum, cerium and neodymium, but for barium at low concentrations (<500 ppm) the neutron activation and the secondary target XRF methods were not suitable. Data on the precision and accuracy of these methods using a series of standard reference rocks are given. The advantages and limitations of each of these methods with respect to the analysis of lateritic materials are discussed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150105
|
|
|
“Current trends in the literature on X-ray emission spectrometry”. Van Grieken R, Markowicz A, Veny P, X-ray spectrometry 20, 271 (1991). http://doi.org/10.1002/XRS.1300200605
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300200605
|
|
|
“Comprehensive microanalytical study of welding aerosols with x-ray and Raman based methods”. Worobiec A, Stefaniak EA, Kiro S, Oprya M, Bekshaev A, Spolnik Z, Potgieter-Vermaak SS, Ennan A, Van Grieken R, X-ray spectrometry 36, 328 (2007). http://doi.org/10.1002/XRS.979
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.979
|
|
|
“Component selection for a compact micro-XRF spectrometer”. Bichlmeier S, Janssens K, Heckel J, Gibson D, Hoffmann P, Ortner HM, X-ray spectrometry 30, 8 (2001). http://doi.org/10.1002/XRS.457
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 33
DOI: 10.1002/XRS.457
|
|
|
“Comparison of x-ray absorption and emission techniques for the investigation of paintings”. Cabal A, Schalm O, Eyskens P, Willems P, Harth A, van Espen P, X-ray spectrometry 44, 141 (2015). http://doi.org/10.1002/XRS.2591
Abstract: Four x-ray techniques: computed radiography, emission radiography, energy-resolved radiography and imaging x-ray fluorescence were compared using four mock-up panel paintings. The paintings have different stratigraphy and pigments and are representative for different historical periods. One of the paintings has a hidden underlying painting. The type of pigments used mainly influences the information obtained by both the emission and absorption measurements; high-Z white pigment and high-Z color pigments giving the best contrast. Each of the techniques revealed interesting aspects of the paintings, but none of them could reveal the hidden painting to a satisfactory level. Due to the statistical quality of the spectral data, x-ray fluorescence gives elemental images with high contrast. The radiographic images are better to reveal the internal structure. Imaging x-ray fluorescence and energy-resolved radiography measurements can be done simultaneously, and the combination has the highest potential for the study of complex multilayer paintings. Copyright (c) 2015 John Wiley & Sons, Ltd.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
DOI: 10.1002/XRS.2591
|
|
|
“Comparison of four mobile, non‐invasive diagnostic techniques for differentiating glass types in historical leaded windows : MA‐XRF , UV–Vis–NIR, Raman spectroscopy and IRT”. Cagno S, van der Snickt G, Legrand S, Caen J, Patin M, Meulebroeck W, Dirkx Y, Hillen M, Steenackers G, Rousaki A, Vandenabeele P, Janssens K, X-Ray Spectrometry , xrs.3185 (2020). http://doi.org/10.1002/XRS.3185
Abstract: This paper critically compares the performance of four non-invasive techniques that match the accuracy, flexibility, time-efficiency, and transportability required for in situ characterization of leaded glass windows: macroscopic X-ray fluorescence imaging (MA-XRF), UV-Vis-NIR, Raman spectroscopy, and infrared thermography (IRT). In order to compare the techniques on equal grounds, all techniques were tested independently of each other by separate research groups on the same historical leaded window tentatively dated to the 17th century, without prior knowledge. The aim was to assess the ability of these techniques to document the conservation history of the window by classifying and grouping the colorless glass panes, based on differences in composition. IRT, MA-XRF and UV-Vis-NIR spectroscopy positively distinguished at least two glass groups, with MA-XRF providing the most detailed chemical information. In particular, based on the ratio between the network modifier (K) and network stabilizer (Ca) and on the level of colorants and decolorizers (Fe, Mn, As), the number of plausible glass families could be strongly reduced. In addition, UV-Vis-NIR detected cobalt at ppm level and gave more specific information on the chromophore Fe2+/Fe(3+)ratio. Raman spectroscopy was hampered by fluorescence caused by the metal ions of the decolorizer in most of the panes, but nevertheless identified one group as HLLA.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
Impact Factor: 1.2
DOI: 10.1002/XRS.3185
|
|
|
“Comparative material characterization of historical and industrial samples by using a compact micro-XRF spectrometer”. Bichlmeier S, Janssens K, Heckel J, Hoffmann P, Ortner HM, X-ray spectrometry 31, 87 (2002). http://doi.org/10.1002/XRS.563
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 12
DOI: 10.1002/XRS.563
|
|