Records |
Author |
Leysen, L.; Roekens, E.; Komy, Z.; Van Grieken, R. |
Title |
A study of the weathering of an historic building |
Type |
A1 Journal article |
Year |
1987 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
|
Volume |
195 |
Issue |
|
Pages |
247-255 |
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
Various bulk and surface analytical techniques were used to study the chemical deterioration of the 13th-to-15th century limestone cathedral in Mechelen, Belgium. The weathering crust on the walls was found to be rich in sulfate, regardless of the geographic orientation. Nitrate and chloride were only detected in minor amounts in the crust and run-off samples. Attack by gaseous sulfur compounds seems to play a dominant role in the stone deterioration mechanism. Electron microprobe analysis showed predominantly bar-shaped gypsum crystals in the crust, and laser microprobe mass spectrometry showed that carbon seems to be responsible for the blackness of most crust samples. Automated electron microprobe analysis also indicated significant differences in the analytical composition of suspensions in run-off water and in rain-water. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
A1987K019500022 |
Publication Date |
2002-07-25 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0003-2670; 1873-4324 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
|
Times cited |
|
Open Access |
|
Notes |
|
Approved |
no |
Call Number |
UA @ admin @ c:irua:116446 |
Serial |
8608 |
Permanent link to this record |
|
|
|
Author |
Cholewa, M.; Legge, G.J.F.; Eeckhaoudt, S.; Van Grieken, R. |
Title |
A study of aluminium-exposed fish using a scanning proton microprobe |
Type |
P3 Proceeding |
Year |
1994 |
Publication |
Proceedings of the Australian Conference on Nuclear Techniques of Analysis |
Abbreviated Journal |
|
Volume |
|
Issue |
|
Pages |
|
Keywords |
P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
|
Publication Date |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Additional Links |
UA library record |
Impact Factor |
|
Times cited |
|
Open Access |
|
Notes |
|
Approved |
no |
Call Number |
UA @ admin @ c:irua:9517 |
Serial |
8594 |
Permanent link to this record |
|
|
|
Author |
Hrdlickova Kuckova, S.; Hamidi-Asl, E.; Sofer, Z.; Marvan, P.; De Wael, K.; Sanyova, J.; Janssens, K. |
Title |
A simplified protocol for usage of new immuno-SERS probes for detection of casein, collagens and ovalbumin in cross-sections of artworks |
Type |
A1 Journal article |
Year |
2018 |
Publication |
Analytical methods |
Abbreviated Journal |
Anal Methods-Uk |
Volume |
10 |
Issue |
9 |
Pages |
1054-1062 |
Keywords |
A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
Although it is now relatively straightforward to identify protein binders in works of art, their proper localization within the corresponding layer still represents a significant analytical challenge. Until now, the identification of proteins has mainly been performed by peptide mass fingerprinting using mass spectrometric methods and their localization in polished paint cross-sections have been realized by optical microscopy via the use of fluorescent stain Sypro Ruby (SR). In this work we propose a simplified protocol for immuno-surface enhanced Raman scattering (immuno-SERS) using gold nanoparticles attached to biphenyl-4,4-dithiol (BPDT) as the SERS-nanotag. These nanoparticles are easily obtainable in the lab and have been used to label multilayered mock up samples prepared as cross-sections to estimate the detection limits of the suggested method. The layers contain egg, casein, and different animal glues binders (prepared in various ratios with linseed oil or a carbohydrate component) mixed with the pigments azurite, vermilion and chalk. The sensitivity of staining agent SR is compared to that of the immuno-SERS protocol for the first time. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000426696100017 |
Publication Date |
2018-02-02 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1759-9660 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
1.9 |
Times cited |
3 |
Open Access |
|
Notes |
; The authors wish to acknowledge the Fund for Scientific Research-Flanders (FWO-Vlaanderen) for the support to act as a Postdoctoral Fellow – Pegasus of the Research Foundation – Flanders, and the grant from Specific University research (MSMT No. 20/2017) from the Czech Republic. This work was supported by the project Advanced Functional Nanorobots (reg. No. CZ.02.1.01/0.0/0.0/15_003/ 0000444 financed by the EFRR). Zdenek Sofer and Petr Marvan were supported by specific university research (MSMT No. 20-SVV/2018). ; |
Approved |
Most recent IF: 1.9 |
Call Number |
UA @ admin @ c:irua:148803 |
Serial |
5831 |
Permanent link to this record |
|
|
|
Author |
Markowicz, A.; Storms, H.; Van Grieken, R. |
Title |
A simple absorption correction for electron probe X-ray microanalysis of bulk samples |
Type |
A1 Journal article |
Year |
1986 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
|
Volume |
15 |
Issue |
2 |
Pages |
115-119 |
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
A simple procedure is proposed for the calculation of the absorption correction factor in electron-probe x-ray microanalysis. It is based on the concept of an effective depth of x-ray production, assuming a rectangular depth distribution function for x-ray generation. This effective x-ray production depth is expressed as a fraction of the x-ray excitation depth given by Whelan's expression. Adequate values for this fraction are presented. Two versions are considered. In the first the effective x-ray production is a function of both the characteristic x-ray energy and the atomic numbers of the matrix elements, whereas in the second one, which is indicated for routine use, the energy dependence is neglected. Calculations pointed to satisfactory results, even for low x-ray energies and high overvoltages. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
A1986C017300007 |
Publication Date |
2005-05-28 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
|
Times cited |
|
Open Access |
|
Notes |
|
Approved |
no |
Call Number |
UA @ admin @ c:irua:113872 |
Serial |
8524 |
Permanent link to this record |
|
|
|
Author |
Worobiec, A.; Samek, L.; Karaszkiewicz, P.; Kontozova-Deutsch, V.; Stefaniak, E.A.; van Meel, K.; Krata, A.; Bencs, L.; Van Grieken, R. |
Title |
A seasonal study of atmospheric conditions influenced by the intensive tourist flow in the Royal Museum of Wawel Castle in Cracow, Poland |
Type |
A1 Journal article |
Year |
2008 |
Publication |
Microchemical journal |
Abbreviated Journal |
|
Volume |
90 |
Issue |
2 |
Pages |
99-106 |
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP) |
Abstract |
Increasingmass tourismcan generate importantmicroclimatic perturbations and also elevate indoor pollution by the transport of fine particulatematter. The purpose of this researchwas to study the indoor air conditions in the RoyalMuseum ofWawel Castle in Cracow, Poland, displaying amongst other valuable works of art also a unique collection of Flemish tapestries. The investigation involved in the determination of transport and deposition of particulate matter brought in by visitors. The microclimate inside the exhibition rooms was also monitored. Samples of suspended particulateswere collected inside and outside themuseuminwinterand summer2006.On days with intensive tourist visits the concentration of total suspended particulates was significantly higher (i.e., 130 µg/m3 inwinter and 49 µg/m3 in summer) than on those days without tourists (i.e., 73 µg/m3 and 22 µg/m3 in winter and summer, respectively). The concentrations of all investigated elementswere also considerably higher during the tourist flow. This was especially valid for soil dust associated elements (Si, K, Ca, Al, and Ti), with considerably higher levels in summer than winter. This could be linked with much more frequent tourist activity in the summer period. Also, the concentration of Clwasmuch higher inwinter than summer, due to the use of deicing salts on the roads and pavements. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000261084200003 |
Publication Date |
2008-04-27 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0026-265x; 0026-265x |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
|
Times cited |
|
Open Access |
|
Notes |
|
Approved |
no |
Call Number |
UA @ admin @ c:irua:70988 |
Serial |
8500 |
Permanent link to this record |
|
|
|
Author |
Salvant, J.; Williams, J.; Ganio, M.; Casadio, F.; Daher, C.; Sutherland, K.; Monico, L.; Vanmeert, F.; De Meyer, S.; Janssens, K.; Cartwright, C.; Walton, M. |
Title |
A Roman Egyptian Painting Workshop : technical investigation of the portraits from Tebtunis, Egypt |
Type |
A1 Journal article |
Year |
2018 |
Publication |
Archaeometry |
Abbreviated Journal |
Archaeometry |
Volume |
60 |
Issue |
4 |
Pages |
815-833 |
Keywords |
A1 Journal article; History; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
Roman-period mummy portraits are considered to be ancient antecedents of modern portraiture. However, the techniques and materials used in their manufacture are not thoroughly understood. Analytical study of the pigments as well as the binding materials helps to address questions on what aspects of the painting practices originate from Pharaonic and/or Graeco-Roman traditions, and can aid in determining the provenance of the raw materials from potential locations across the ancient Mediterranean and European worlds. Here, one of the largest assemblages of mummy portraits to remain intact since their excavation from the site of Tebtunis in Egypt was examined using multiple analytical techniques to address how they were made. The archaeological evidence suggests that these portraits were products of a single workshop and, correspondingly, they are found to be made using similar techniques and materials: wax-based and lead white-rich paint combined with a variety of iron-based pigments (including hematite, goethite and jarosite), as well as Egyptian blue, minium, indigo and madder lake to create subtle variations and tones. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000438195100011 |
Publication Date |
2017-11-24 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0003-813x; 1475-4754 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
1.47 |
Times cited |
6 |
Open Access |
|
Notes |
; This collaborative initiative is part of NU-ACCESS's broad portfolio of activities, made possible by generous support of the Andrew W. Mellon Foundation as well as supplemental support provided by the Materials Research Center, the Office of the Vice President for Research, the McCormick School of Engineering and Applied Science and the Department of Materials Science and Engineering at Northwestern University. This work made use of the Keck-II facility of the NUANCE Center at Northwestern University, which has received support from the Soft and Hybrid Nanotechnology Experimental (SHyNE) Resource (NSF NNCI-1542205); the MRSEC program (NSF DMR-1121262) at the Materials Research Center; the International Institute for Nanotechnology (IIN); the Keck Foundation; and the State of Illinois, through the IIN. Part of this research was carried out at the light source PETRA III at DESY, a member of the Helmholtz Association (HGF), and at ESRF (experiment no. HG-79). We are grateful to Marine Cotte and Wout De Nolf for their support during the experiment at beamline ID21. We would like to thank Gerald Falkenberg and Jan Garrevoet for their assistance in using beamline P06. ; |
Approved |
Most recent IF: 1.47 |
Call Number |
UA @ admin @ c:irua:152396 |
Serial |
5455 |
Permanent link to this record |
|
|
|
Author |
De Henau, S.; Tilleman, L.; Vangheel, M.; Luyckx, E.; Trashin, S.; Pauwels, M.; Germani, F.; Vlaeminck, C.; Vanfleteren, J.R.; Bert, W.; Pesce, A.; Nardini, M.; Bolognesi, M.; De Wael, K.; Moens, L.; Dewilde, S.; Braeckman, B.P. |
Title |
A redox signalling globin is essential for reproduction in Caenorhabditis elegans |
Type |
A1 Journal article |
Year |
2015 |
Publication |
Nature communications |
Abbreviated Journal |
Nat Commun |
Volume |
6 |
Issue |
|
Pages |
8782 |
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
Moderate levels of reactive oxygen species (ROS) are now recognized as redox signalling molecules. However, thus far, only mitochondria and NADPH oxidases have been identified as cellular sources of ROS in signalling. Here we identify a globin (GLB-12) that produces superoxide, a type of ROS, which serves as an essential signal for reproduction in C. elegans. We find that GLB-12 has an important role in the regulation of multiple aspects in germline development, including germ cell apoptosis. We further describe how GLB-12 displays specific molecular, biochemical and structural properties that allow this globin to act as a superoxide generator. In addition, both an intra- and extracellular superoxide dismutase act as key partners of GLB-12 to create a transmembrane redox signal. Our results show that a globin can function as a driving factor in redox signalling, and how this signal is regulated at the subcellular level by multiple control layers. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000367577100002 |
Publication Date |
2015-12-01 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
2041-1723 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
12.124 |
Times cited |
20 |
Open Access |
|
Notes |
; We thank Dr K. Matsumoto and Dr T. Mizuno for kindly providing the mek-1(ks54) sek-1(km4) double mutant, the antibody anti-PMK-1 and technical advice on antibody use; Dr D. Kim for kindly providing the pDK177 RNAi strain; Dr M. Ubbink and Dr Q. Bashir for providing CCP; Dr K. Oegema and the OD lab for sharing technical expertise; M. Couvreur for assistance in generating transgenic lines; and Dr T. Dansen for the final support. Some strains were provided by the CGC, which is funded by the NIH Office of Research Infrastructure Programs (P40 OD010440). S.D.H. and F.G. are PhD fellows of the Fund for Scientific Research (FWO). Financial support to S.D. and L.M. was provided by the University of Antwerp (BOF UA TOP 2006), to K.D.W., S.D. and S.T. by the University of Antwerp (BOF-GOA) and to S.D., L.M., B.P.B., by FWO project G.0247.09. ; |
Approved |
Most recent IF: 12.124; 2015 IF: 11.470 |
Call Number |
UA @ admin @ c:irua:129310 |
Serial |
5809 |
Permanent link to this record |
|
|
|
Author |
Wuyts, K.; Hofman, J.; van Wittenberghe, S.; Nuyts, G.; De Wael, K.; Samson, R. |
Title |
A new opportunity for biomagnetic monitoring of particulate pollution in an urban environment using tree branches |
Type |
A1 Journal article |
Year |
2018 |
Publication |
Atmospheric environment : an international journal |
Abbreviated Journal |
Atmos Environ |
Volume |
190 |
Issue |
190 |
Pages |
177-187 |
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
Environmental magnetism, and the magnetic leaf signal in particular, is amply investigated and applied as proxy for atmospheric particulate matter pollution. In this study, we investigated the magnetic signal of annual segments of tree branches, and the composition of particles deposited hereon. Branches are, contrary to leaves of deciduous trees, available during leaf-off seasons and exposed to air pollution year-round. We examined the intra- and inter-tree variation in saturation isothermal remanent magnetization (SIRM) of branch internodes of London plane (Platanus x aeerifolia Willd.) trees in an urban environment. The branch SIRM, normalized by surface area, ranged from 18 to 650 x 10(-6) angstrom; the median amounted to 106 x 10(-6) angstrom. Most of the branch magnetic signal was attributed to the epidermis or bark, and the presence of metal-containing particles on the branch surfaces was confirmed by SEM-EDX. The location of the trees and the height, the depth in the crown and the age of the branches significantly influenced the branch SIRM. The median branch SIRM was up to 135% higher near a busy ring road than in quiet environments (city park and quiet street canyon), and was linked to the presence of Fe-rich particles with co-occurrence of trace metals such as Cr, Cu, Zn and Mn on the branch surface. Within the tree crowns, the branch SIRM generally decreased with increasing height, and was 22% higher in the interior than at the periphery of the crowns. Within the branches, the SIRM increased with each year of exposure, but did not relate to year-to-year variation in particle concentrations due to branch surface changes (epidermis shedding). Our results provide indications that branches can be a valuable alternative for biomagnetic monitoring of particulate pollution, but intra-tree variability in branch SIRM can be substantial due to the branch's location in the tree and branch age. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000444659400017 |
Publication Date |
2018-07-11 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1352-2310 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
3.629 |
Times cited |
3 |
Open Access |
|
Notes |
; We would like to thank the city council services of the city of Antwerp for their logistical support. We are grateful to Ana Castanheiro and Leen Van Ham for laboratory and SEM assistance. JH is supported as postdoctoral fellow of the Research Foundation Flanders (FWO; 12I4816N) and SVW is supported by a Marie Sklodowska-Curie Individual Fellowship under the grant agreement no 701815 FLUOPHOT. ; |
Approved |
Most recent IF: 3.629 |
Call Number |
UA @ admin @ c:irua:153607 |
Serial |
5454 |
Permanent link to this record |
|
|
|
Author |
Pauwels, D.; Pilehvar, S.; Geboes, B.; Hubin, A.; De Wael, K.; Breugelmans, T. |
Title |
A new multisine-based impedimetric aptasensing platform |
Type |
A1 Journal article |
Year |
2016 |
Publication |
Electrochemistry communications |
Abbreviated Journal |
Electrochem Commun |
Volume |
71 |
Issue |
|
Pages |
23-27 |
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Applied Electrochemistry & Catalysis (ELCAT) |
Abstract |
In this work an aptamer-based biosensor is combined with a multisine electrochemical impedance spectroscopy sensing methodology into a novel and promising biosensing strategy. Employing a multisine instead of a traditional single sine measuring method allows the detection and quantification of parameters that provide information about the accuracy and reliability of the results, such as noise and distortions. This does not only lead to a shorter measurement time, but it also enables an easy and fast evaluation of the quality of the data and fitting, leading to more accurate results. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000383445000006 |
Publication Date |
2016-07-23 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1388-2481; 1873-1902 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
4.396 |
Times cited |
1 |
Open Access |
|
Notes |
; ; |
Approved |
Most recent IF: 4.396 |
Call Number |
UA @ admin @ c:irua:134765 |
Serial |
5746 |
Permanent link to this record |
|
|
|
Author |
Karabidak, S.M.; Čevik, U.; Kaya, S. |
Title |
A new method to compensate for counting losses due to system dead time |
Type |
A1 Journal article |
Year |
2009 |
Publication |
Nuclear instruments and methods in physics research : A: accelerators, spectrometers, detectors and associated equipment |
Abbreviated Journal |
|
Volume |
603 |
Issue |
3 |
Pages |
361-364 |
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
Determination of count losses and pile-up pulse effects in quantitative and qualitative analysis became a vital step in various analyses. Therefore, compensating for counting losses is of importance. These counting losses are due to the pulse pile-up, paralyzable and non-paralyzable system dead time or a combination of these mechanisms. In this work, a new method is suggested for the correction of dead time losses resulting from the above mechanisms. For this purpose, a source code was developed. It was found that the peaking time was an important parameter over system dead time. The method suggested seems to be more effective even at high count rate. (C) 2009 Elsevier B.V. All rights reserved. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000266829400021 |
Publication Date |
2009-02-14 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0168-9002 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
|
Times cited |
|
Open Access |
|
Notes |
|
Approved |
no |
Call Number |
UA @ admin @ c:irua:94550 |
Serial |
8304 |
Permanent link to this record |
|
|
|
Author |
Ro, C.-U.; Osán, J.; Szalóki, I.; de Hoog, J.; Worobiec, A.; Van Grieken, R. |
Title |
A Monte Carlo program for quantitative electron-induced x-ray analysis of individual particles |
Type |
A1 Journal article |
Year |
2003 |
Publication |
Analytical chemistry |
Abbreviated Journal |
|
Volume |
75 |
Issue |
4 |
Pages |
851-859 |
Keywords |
A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000181073800021 |
Publication Date |
2003-02-14 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0003-2700; 5206-882x |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
|
Times cited |
|
Open Access |
|
Notes |
|
Approved |
no |
Call Number |
UA @ admin @ c:irua:40613 |
Serial |
8279 |
Permanent link to this record |
|
|
|
Author |
Kempenaers, L.; Janssens, K.; Vincze, L.; Vekemans, B.; Somogyi, A.; Drakopoulos, M.; Simionovici, A.S.; Adams, F. |
Title |
A Monte Carlo model for studying the microheterogeneity of trace elements in reference materials by means of synchrotron microscopic X-ray fluorescence |
Type |
A1 Journal article |
Year |
2002 |
Publication |
Analytical chemistry |
Abbreviated Journal |
Anal Chem |
Volume |
74 |
Issue |
19 |
Pages |
5017-5026 |
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000178418100031 |
Publication Date |
2002-09-30 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0003-2700; 5206-882x |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
6.32 |
Times cited |
21 |
Open Access |
|
Notes |
|
Approved |
Most recent IF: 6.32; 2002 IF: 5.094 |
Call Number |
UA @ admin @ c:irua:39871 |
Serial |
5734 |
Permanent link to this record |
|
|
|
Author |
De Meyer, S.; Vanmeert, F.; Janssens, K.; Storme, P. |
Title |
A mobile scanner for xrpd-imaging of paintings in transmission and reflection geometry |
Type |
P1 Proceeding |
Year |
2017 |
Publication |
ACTA ARTIS ACADEMICA 2017: PAINTING AS A STORY
T2 – 6th Interdisciplinary ALMA Conference, JUN 01-03, 2017, Brno, CZECH REPUBLIC |
Abbreviated Journal |
|
Volume |
|
Issue |
|
Pages |
29-38 |
Keywords |
P1 Proceeding; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES) |
Abstract |
In this paper the possibilities and limitations of a non-invasive prototype of macroscopic X-ray powder diffraction scanning device employed in transmission and reflection mode are demonstrated. Contrarily to e.g. macroscopic X-ray fluorescence scanners, which gather information on the elemental level, the prototype instrument allows to obtain information on the crystallographic structure of the components. When applied to cultural heritage artefacts, it becomes possible to identify and localize crystalline pigments. Furthermore, it became clear that different information can be available depending on the geometry of the scanner components. In transmission mode information over the entire stratigraphy of the painting is gathered, which is useful to e.g. identify background substrates and major pigments. On the other hand, reflection-XRPD is a surface-sensitive technique and allows the identification of pigments and degradation products located on the surface. The data acquired during both experiments can be presented as two-dimensional distribution maps which show the spatial distribution of every identified pigment. The complementary nature of transmission and reflectionmode makes it possible to gain more insight into the stratigraphy of the painting which is valuable information for conservation and restoration scientists. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000430517600002 |
Publication Date |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
978-80-87108-75-8 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
|
Times cited |
|
Open Access |
|
Notes |
|
Approved |
no |
Call Number |
UA @ admin @ c:irua:189869 |
Serial |
7392 |
Permanent link to this record |
|
|
|
Author |
Alfeld, M.; Pedroso, J.V.; van Hommes, M.E.; van der Snickt, G.; Tauber, G.; Blaas, J.; Haschke, M.; Erler, K.; Dik, J.; Janssens, K. |
Title |
A mobile instrument for in situ scanning macro-XRF investigation of historical paintings |
Type |
A1 Journal article |
Year |
2013 |
Publication |
Journal of analytical atomic spectrometry |
Abbreviated Journal |
J Anal Atom Spectrom |
Volume |
28 |
Issue |
5 |
Pages |
760-767 |
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
Scanning macro-X-ray fluorescence analysis (MA-XRF) is rapidly being established as a technique for the investigation of historical paintings. The elemental distribution images acquired by this method allow for the visualization of hidden paint layers and thus provide insight into the artist's creative process and the painting's conservation history. Due to the lack of a dedicated, commercially available instrument the application of the technique was limited to a few groups that constructed their own instruments. We present the first commercially available XRF scanner for paintings, consisting of an X-ray tube mounted with a Silicon-Drift (SD) detector on a motorized stage to be moved in front of a painting. The scanner is capable of imaging the distribution of the main constituents of surface and sub-surface paint layers in an area of 80 by 60 square centimeters with dwell times below 10 ms and a lateral resolution below 100 mu m. The scanner features for a broad range of elements between Ti (Z = 22) and Mo (Z = 42) a count rate of more than 1000 counts per second (cps)?mass percent and detection limits of 100 ppm for measurements of 1 s duration. Next to a presentation of spectrometric figures of merit, the value of the technique is illustrated through a case study of a painting by Rembrandt's student Govert Flinck (1615-1660). |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000317674200019 |
Publication Date |
2013-03-22 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0267-9477 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
3.379 |
Times cited |
106 |
Open Access |
|
Notes |
; This research was supported by the Interuniversity Attraction Poles Programme – Belgian Science Policy (IUAP VI/16). The text also presents the results of GOA “XANES meets ELNES” (Research Fund University of Antwerp, Belgium) and from FWO (Brussels, Belgium) projects no. G.0704.08 and G.01769.09. M. Alfeld receives a Ph. D. fellowship of the Research Foundation-Flanders (FWO). We thank J. Langerock for allowing us to examine the portable altar triptych shown in Fig. 5. ; |
Approved |
Most recent IF: 3.379; 2013 IF: 3.396 |
Call Number |
UA @ admin @ c:irua:108517 |
Serial |
5453 |
Permanent link to this record |
|
|
|
Author |
Goossenaerts, C.; Van Grieken, R.; Jacob, W.; Witters, H.; Vanderborght, O. |
Title |
A microanalytical study of the gills of aluminium-exposed rainbow trout (Salmo gairdneri) |
Type |
A1 Journal article |
Year |
1988 |
Publication |
International journal of environmental analytical chemistry |
Abbreviated Journal |
|
Volume |
34 |
Issue |
3 |
Pages |
227-237 |
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
A1988T017900005 |
Publication Date |
2007-07-07 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0306-7319 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
|
Times cited |
|
Open Access |
|
Notes |
|
Approved |
no |
Call Number |
UA @ admin @ c:irua:116579 |
Serial |
8240 |
Permanent link to this record |
|
|
|
Author |
Eeckhaoudt, S.; Landsberg, J.; Van Grieken, R.; Jacob, W.; Watt, F.; Witters, H. |
Title |
A microanalytical study of the gills of aluminium-exposed catfish |
Type |
P1 Proceeding |
Year |
1993 |
Publication |
Institute of physics conference series
T2 – Proceedings of the 13th International Congress on X-Ray Optics and Microanalysis / Kenway, P.B. [edit.] |
Abbreviated Journal |
|
Volume |
|
Issue |
|
Pages |
251-254 |
Keywords |
P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
Through a combined use of light- and electron microscopy with microanalytical techniques, the aluminium distribution in gills of aluminium-exposed catfish was investigated. This study demonstrates that also with the ''acid-resistant'' catfish, exposed during seven days to acidified water (pH=4.3) with an elevated aluminium concentration (1 mg Al/l), aluminium can be found at, and even in, the gills. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
A1993LW34000051 |
Publication Date |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0951-3248; 2154-6630 |
ISBN |
|
Additional Links |
UA library record; WoS full record |
Impact Factor |
|
Times cited |
|
Open Access |
|
Notes |
|
Approved |
no |
Call Number |
UA @ admin @ c:irua:6264 |
Serial |
8239 |
Permanent link to this record |
|
|
|
Author |
Goossenaerts, C.H.; Verbueken, A.H.; Jacob, W.A.; Van Praag, H.J.; Van Grieken, R.E. |
Title |
A microanalytical study of green and necrotic needle tissue |
Type |
H3 Book chapter |
Year |
1987 |
Publication |
|
Abbreviated Journal |
|
Volume |
|
Issue |
|
Pages |
224-234
T2 - Direct effects of dry and wet deposit |
Keywords |
H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
|
Publication Date |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Additional Links |
UA library record |
Impact Factor |
|
Times cited |
|
Open Access |
|
Notes |
|
Approved |
no |
Call Number |
UA @ admin @ c:irua:117533 |
Serial |
8237 |
Permanent link to this record |
|
|
|
Author |
Janssens, K.; Vekemans, B.; Vincze, L.; Adams, F.; Rindby, A. |
Title |
A micro XRF spectrometer based on rotating anode generator and capillary optics |
Type |
A1 Journal article |
Year |
1996 |
Publication |
Spectrochimica acta: part B : atomic spectroscopy |
Abbreviated Journal |
|
Volume |
51 |
Issue |
13 |
Pages |
1661-1678 |
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
|
Publication Date |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0584-8547; 0038-6987 |
ISBN |
|
Additional Links |
UA library record |
Impact Factor |
|
Times cited |
|
Open Access |
|
Notes |
|
Approved |
no |
Call Number |
UA @ admin @ c:irua:14256 |
Serial |
5720 |
Permanent link to this record |
|
|
|
Author |
Bernardi, A.; Becherini, F.; Bonazza, A.; Van Grieken, R.; et al. |
Title |
A methodology to monitor the pollution impact on historic buildings surfaces : the TeACH project |
Type |
P1 Proceeding |
Year |
2012 |
Publication |
Lecture notes in computer science
T2 – Progress in Cultural Heritage Preservation : proceedings of EUROMED-2012, the 4th International Conference on Cultural Heritage / Ioannides, M. [edit.]; et al. |
Abbreviated Journal |
|
Volume |
|
Issue |
|
Pages |
765-775 |
Keywords |
P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
The available scenarios of pollutant trends in Europe indicate that the effect of industrial, domestic and transport emissions on corrosion and soiling will continue to constitute a serious threat to Cultural Heritage. Such effects require improved methods for a more accurate diagnosis, monitoring and assessment of the damage. Within this framework, the monitoring methodology applied within the European project TeACH (Technologies and tools to prioritize assessment and diagnosis of air pollution impact on immovable and movable cultural heritage) (2008-2012) allows to assess the impact of the main pollutants on historic buildings. As a part of this approach, a new kit able to monitor the environmental parameters critical for the conservation of architectural surfaces and to evaluate the related damage in terms of surface color change was developed. The monitoring methodology described in the present paper has valuable application potential in the definition of preventive conservation strategies for a wide range of heritage assets. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
|
Publication Date |
2012-10-21 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
978-3-642-34233-2 |
ISBN |
|
Additional Links |
UA library record |
Impact Factor |
|
Times cited |
|
Open Access |
|
Notes |
|
Approved |
no |
Call Number |
UA @ admin @ c:irua:126672 |
Serial |
8222 |
Permanent link to this record |
|
|
|
Author |
Schalm, O.; de Raedt, I.; Caen, J.; Janssens, K. |
Title |
A methodology for the identification of glass panes of different origin in a single stained glass window: application on two 13th century windows |
Type |
A1 Journal article |
Year |
2010 |
Publication |
Journal of cultural heritage |
Abbreviated Journal |
J Cult Herit |
Volume |
11 |
Issue |
4 |
Pages |
487-492 |
Keywords |
A1 Journal article; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
The chemical composition of 11 glass panes originating from two 13th century non-figurative windows were analyzed by means of Scanning Electron MicroscopyEnergy Dispersive X-ray system (SEM-EDX). The windows were discovered in the back-wall of the triforium during the restoration of the choir of the cathedral St. Michael and St. Gudule in Brussels (Belgium). In order to determine if these windows were fabricated with glass of different origin or not, the compositional difference between the panes were compared with the variation in composition as a result of the following causes: (1) compositional fluctuation between panes cut from the same sheet of glass, (2) compositional fluctuation caused when panes are cut from different sheets that were made with the same batch, (3) compositional fluctuation caused when the glass is made from different batches at the same production center, and (4) compositional fluctuation as a result of glass produced at different fabrication centers. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000282680500016 |
Publication Date |
2010-07-07 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1296-2074 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
1.838 |
Times cited |
7 |
Open Access |
|
Notes |
; ; |
Approved |
Most recent IF: 1.838; 2010 IF: 1.162 |
Call Number |
UA @ admin @ c:irua:84942 |
Serial |
5707 |
Permanent link to this record |
|
|
|
Author |
Jambers, W.; Van Grieken, R. |
Title |
A message in the dust |
Type |
A3 Journal article |
Year |
1996 |
Publication |
Analysis Europe |
Abbreviated Journal |
|
Volume |
|
Issue |
|
Pages |
25-29 |
Keywords |
A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
|
Publication Date |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Additional Links |
UA library record |
Impact Factor |
|
Times cited |
|
Open Access |
|
Notes |
|
Approved |
no |
Call Number |
UA @ admin @ c:irua:14638 |
Serial |
8216 |
Permanent link to this record |
|
|
|
Author |
Silva, A.L.M.; Carvalho, M.L.; Janssens, K.; Veloso, J.F.C.A. |
Title |
A large area full-field EDXRF imaging system based on a THCOBRA gaseous detector |
Type |
A1 Journal article |
Year |
2015 |
Publication |
Journal of analytical atomic spectrometry |
Abbreviated Journal |
J Anal Atom Spectrom |
Volume |
30 |
Issue |
2 |
Pages |
343-352 |
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
By taking advantage of the attractive features in terms of gain, position and energy resolution of the 2D-THCOBRA detector, a new large area Full-Field X-ray Fluorescence Imaging (FF-XRFI) system for EDXRF imaging applications was developed. The proposed FF-XRFI system has an active area of 10 x 10 cm(2) and can be used to examine macroscopic samples with a moderately good energy resolution (< 1.6 keV FWHM at 8 keV) and a suitable spatial resolution (similar to 500 mu m FWHM). This combination of characteristics allows us to record elemental distribution maps from the surface of different sample types by combining image and energy information. Two different approaches were used for X-ray optics, one based on a single pinhole and another based on a parallel multiple-hole collimator. To illustrate the system capabilities, some sample examples were imaged and studied. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000349145700003 |
Publication Date |
2014-10-24 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0267-9477 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
3.379 |
Times cited |
11 |
Open Access |
|
Notes |
; The authors thank Stijn Legrand for acquisition of the MAXRF maps shown in Fig. 15. This work was partially supported by projects CERN/FP/123604/2011 FEDER, COMPETE and FCT (Lisbon) programs. A. L. M. Silva is supported by the QREN programme Mais Centro – Programa Operacional Regional do Centro, FEDER and COMPETE, through the project Biomaterials for Regenerative Medicine (CENTRO-07-ST24-FEDER-002030). ; |
Approved |
Most recent IF: 3.379; 2015 IF: 3.466 |
Call Number |
UA @ admin @ c:irua:125297 |
Serial |
5452 |
Permanent link to this record |
|
|
|
Author |
Janssens, K.; Vekemans, B.; Rindby, A.; Vincze, L.; Adams, F. |
Title |
A laboratory mu-XRF spectrometer employing capillary optics |
Type |
P1 Proceeding |
Year |
1995 |
Publication |
|
Abbreviated Journal |
|
Volume |
|
Issue |
|
Pages |
159-160 |
Keywords |
P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
A1995BE26U00071 |
Publication Date |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1-56081-919-7 |
ISBN |
|
Additional Links |
UA library record; WoS full record |
Impact Factor |
|
Times cited |
|
Open Access |
|
Notes |
|
Approved |
no |
Call Number |
UA @ admin @ c:irua:104453 |
Serial |
5687 |
Permanent link to this record |
|
|
|
Author |
Pilehvar, S.; Reinemann, C.; Bottari, F.; Vanderleyden, E.; Van Vlierberghe, S.; Blust, R.; Strehlitz, B.; De Wael, K. |
Title |
A joint action of aptamers and gold nanoparticles chemically trapped on a glassy carbon support for the electrochemical sensing of ofloxacin |
Type |
A1 Journal article |
Year |
2017 |
Publication |
Sensors and actuators : B : chemical |
Abbreviated Journal |
Sensor Actuat B-Chem |
Volume |
240 |
Issue |
|
Pages |
1024-1035 |
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
A joint action of ssDNA aptamers and electrochemistry is a key element in developing successful biosensing platforms, since aptamers are capable of binding various targets with high specificity, and electrochemistry is one of the most sensitive techniques for on-site detections. A continuous search for improved immobilization and sensing strategies of aptamers on transducer surfaces resulted in the strategy presented in this article. The strategy is based on the covalent attachment of gold nanoparticles on the surface of glassy carbon electrodes through sulfhydryl-terminated monolayer, acting as a glue to connect AuNPs on the electrode. The covalently attached gold nanoparticles modified glassy carbon electrodes have been applied for the efficient immobilization of thiolated ssDNA probes, with a surface coverage of about 8.54 × 1013 molecules cm−2 which was 7-fold higher than that on the electrochemically deposited gold nanoparticles. Consequently, improved sensitivity, good reproducibility and stability are achieved for electrochemical aptasensor. Combined with the high affinity and specificity of an aptamer, a simple, novel, rapid, sensitive and label-free electrochemical aptasensor was successfully fabricated for ofloxacin (OFL) detection. The linear dynamic range of the sensor varies between 5 × 10−8 to 2 × 10−5 M OFL with a detection limit of 1 × 10−9 M OFL. A potential application in environmental monitoring was demonstrated by using this sensing strategy for the determination of OFL in (experimentally spiked) real samples such as tap water and effluent of sewage treatment plant. The proposed nanoaptasensor combines the advantages of the covalent attachment of neatly arranged AuNPs (enlarged active surface area and strengthened electrochemical signal) and the elimination of labels for the amplified detection of OFL, with the covalent attachment of highly specific aptamers to the surface of the modified electrode. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000390622300123 |
Publication Date |
2016-09-16 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0925-4005 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
5.401 |
Times cited |
21 |
Open Access |
|
Notes |
; This work was financially supported by the University of Antwerp (BOF), The Research Foundation – Flanders (FWO) and The Hercules Foundation. S. P. is thankful to UA for DOCPRO financial support. C.R. and B.S. acknowledge funding by the Federal Ministry of Education and Research (BMBF) under contract no. 03X0094B. ; |
Approved |
Most recent IF: 5.401 |
Call Number |
UA @ admin @ c:irua:135410 |
Serial |
5682 |
Permanent link to this record |
|
|
|
Author |
Meysman, F.J.R.; Cornelissen, R.; Trashin, S.; Bonne, R.; Hidalgo-Martinez, S.; van der Veen, J.; Blom, C.J.; Karman, C.; Hou, J.-L.; Eachambadi, R.T.; Geelhoed, J.S.; De Wael, K.; Beaumont, H.J.E.; Cleuren, B.; Valcke, R.; van der Zant, H.S.J.; Boschker, H.T.S.; Manca, J.V. |
Title |
A highly conductive fibre network enables centimetre-scale electron transport in multicellular cable bacteria |
Type |
A1 Journal article |
Year |
2019 |
Publication |
Nature communications |
Abbreviated Journal |
Nat Commun |
Volume |
10 |
Issue |
10 |
Pages |
4120 |
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
Biological electron transport is classically thought to occur over nanometre distances, yet recent studies suggest that electrical currents can run along centimetre-long cable bacteria. The phenomenon remains elusive, however, as currents have not been directly measured, nor have the conductive structures been identified. Here we demonstrate that cable bacteria conduct electrons over centimetre distances via highly conductive fibres embedded in the cell envelope. Direct electrode measurements reveal nanoampere currents in intact filaments up to 10.1 mm long (>2000 adjacent cells). A network of parallel periplasmic fibres displays a high conductivity (up to 79 S cm(-1)), explaining currents measured through intact filaments. Conductance rapidly declines upon exposure to air, but remains stable under vacuum, demonstrating that charge transfer is electronic rather than ionic. Our finding of a biological structure that efficiently guides electrical currents over long distances greatly expands the paradigm of biological charge transport and could enable new bio-electronic applications. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000485216900006 |
Publication Date |
2019-09-11 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
2041-1723 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
12.124 |
Times cited |
10 |
Open Access |
|
Notes |
; This research was financially supported by the European Research Council under the European Union's Seventh Framework Programme (FP/2007-2013) through ERC Grant 306933 (F.J.R.M.), the Research Foundation Flanders (FWO project grant G031416N), and the Netherlands Organisation for Scientific Research (VICI grant 016.VICI.170.072 to F.J.R.M.). H.J.E.B., C.J.B. and H.S.J.Z. were supported by the Netherlands Organisation for Scientific Research (NWO/OCW), as part of the Frontiers of Nanoscience program. R.B. is supported by an 'aspirant' grant from Research Foundation Flanders (FWO). We thank Laurine Burdorf (UAntwerpen) for help with Thiothrix cultivation, Marlies Nijemeisland (Faculty of Aerospace, TU Delft) for assistance with Raman microscopy, and Jan D'Haen (UHasselt) and Renaat Dasseville (UGent) for help with EM imaging. ; |
Approved |
Most recent IF: 12.124 |
Call Number |
UA @ admin @ c:irua:162795 |
Serial |
5451 |
Permanent link to this record |
|
|
|
Author |
De Jong, M. |
Title |
A highly accurate portable electrochemical sensor for cocaine : from methodology to testing in the field |
Type |
Doctoral thesis |
Year |
2020 |
Publication |
|
Abbreviated Journal |
|
Volume |
|
Issue |
|
Pages |
263 p. |
Keywords |
Doctoral thesis; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
|
Publication Date |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Additional Links |
UA library record |
Impact Factor |
|
Times cited |
|
Open Access |
|
Notes |
|
Approved |
Most recent IF: NA |
Call Number |
UA @ admin @ c:irua:170912 |
Serial |
6538 |
Permanent link to this record |
|
|
|
Author |
Thirumalraj, alamurugan; Palanisamy, S.; Chen, S.-M.; De Wael, K. |
Title |
A graphene/gelatin composite material for the entrapment of hemoglobin for bioelectrochemical sensing applications |
Type |
A1 Journal article |
Year |
2016 |
Publication |
Journal of the electrochemical society |
Abbreviated Journal |
J Electrochem Soc |
Volume |
163 |
Issue |
7 |
Pages |
265-271 |
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
In the present work, a novel graphene (GN) and gelatin (GTN) composite was prepared and used as an immobilization matrix for hemoglobin (Hb). Compared with Hb immobilized on a bare, GN or GTN modified glassy carbon electrode (GCE), a stable and pair of well-defined quasi redox couple was observed at an Hb modified GN/GTN composite GCE at a formal potential of −0.306 V versus Ag|AgCl. The direct electrochemical behavior of Hb was greatly enhanced by the presence of both GTN and GN. A heterogeneous electron transfer rate constant (Ks) was calculated as 3.82 s−1 for Hb immobilized at GN/GTN modified GCE, which indicates the fast direct electron transfer of Hb toward the electrode surface. The biosensor shows a stable and wide linear response for H2O2 in the linear response range from 0.1 μM to 786.6 μM with an analytical sensitivity and limit of detection of 0.48 μAμM−1 cm−2 and 0.04 μM, respectively. The fabricated biosensor holds its high selectivity in the presence of potentially active interfering species and metal ions. The biosensor shows its satisfactory practical ability in the commercial contact lens solution and human serum samples. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000377412900047 |
Publication Date |
2016-04-08 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0013-4651 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
3.259 |
Times cited |
9 |
Open Access |
|
Notes |
; This project was supported by the Ministry of Science and Technology (project no. NSC1012113M027001MY3), Taiwan (Republic of China). The authors express their sincere thanks to Prof. Bih-Show Lou, Chemistry Division, Center for General Education, Chang Gung University, Tao-Yuan, Taiwan for providing the human serum samples. ; |
Approved |
Most recent IF: 3.259 |
Call Number |
UA @ admin @ c:irua:132627 |
Serial |
5635 |
Permanent link to this record |
|
|
|
Author |
Rather, J.A.; Pilehvar, S.; De Wael, K. |
Title |
A graphene oxide amplification platform tagged with tyrosinase-zinc oxide quantum dot hybrids for the electrochemical sensing of hydroxylated polychlorobiphenyls |
Type |
A1 Journal article |
Year |
2014 |
Publication |
Sensors and actuators : B : chemical |
Abbreviated Journal |
Sensor Actuat B-Chem |
Volume |
190 |
Issue |
|
Pages |
612-620 |
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
Graphene oxide can act as an amplification platform for the immobilization of a hybrid structure composed of tyrosinase (Tyr) and zinc oxide quantum dots (ZnO QDs). This article describes how this platform increases the sensitivity for the detection of hydroxylated polychlorobiphenyls (OH-PCBs). The adsorption of Tyr (with low isoelectric point) on the positively charged surface of ZnO QDs is based on electrostatic interactions. The scanning electron microscopic images and UVvis spectroscopic analysis demonstrated the adsorption of Tyr on ZnO QDs. The stepwise assembly process of the fabricated biosensor was characterized by cyclic voltammetry and electrochemical impedance spectroscopy. The synthesized ZnO QDs and graphene oxide were characterized by Raman spectroscopy, infrared spectroscopy, X-ray diffraction and scanning electron microscopic techniques. The determination of OH-PCBs was carried out by using square wave voltammetry over the concentration range of 2.827.65 μM with a detection limit of 0.15 μM with good reproducibility, selectivity and acceptable stability. The high value of surface coverage of ZnO QDs and small value of MichaelisMenten constant (View the MathML source) confirmed an excellent loading of the Tyr and a high affinity of the biosensor toward the detection of OH-PCBs. This biosensor and the described sensing platform offer a great potential for rapid, cost-effective and on-field analysis of OH-PCBs. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000326687700082 |
Publication Date |
2013-09-14 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0925-4005 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
5.401 |
Times cited |
26 |
Open Access |
|
Notes |
; The authors are highly thankful for the mobility grant (Non-Europe Postdoc Fellowship) for one of the author (Jahangir Ahmad Rather) supported by the Belgian Federal Science Policy (Belspo) co-funded by the Marie Curie Actions from the European Commission. Sanaz Pilehvar is funded by BOF-DOCPRO UA. We are also thankful to the EMAT (Electron Microscopy for Materials Science) group and Laboratory of adsorption and catalysis group of the University of Antwerp for the XRD, Raman and FTIR characterization of samples (GO and ZnO QDs). ; |
Approved |
Most recent IF: 5.401; 2014 IF: 4.097 |
Call Number |
UA @ admin @ c:irua:110566 |
Serial |
5636 |
Permanent link to this record |
|
|
|
Author |
Janssens, K.; van Espen, P. |
Title |
A general-purpose interface between fortran and the low-level functions of the ibm-pc |
Type |
A1 Journal article |
Year |
1988 |
Publication |
Trends in analytical chemistry |
Abbreviated Journal |
|
Volume |
7 |
Issue |
4 |
Pages |
128-130 |
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
A1988M999800003 |
Publication Date |
2002-07-25 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0165-9936 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
|
Times cited |
|
Open Access |
|
Notes |
|
Approved |
no |
Call Number |
UA @ admin @ c:irua:149778 |
Serial |
5450 |
Permanent link to this record |
|
|
|
Author |
Vincze, L.; Janssens, K.; Adams, F. |
Title |
A general Monte-Carlo simulation of energy-dispersive X-ray fluorescence spectrometers : 1 : unpolarized radiation, homogenious samples |
Type |
A1 Journal article |
Year |
1993 |
Publication |
Spectrochimica acta: part B : atomic spectroscopy |
Abbreviated Journal |
|
Volume |
48 |
Issue |
4 |
Pages |
553-573 |
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
A general Monte Carlo program for the simulation of X-ray fluorescence (XRF) spectrometers is presented. The global layout of the program is discussed and the way in which variance reduction techniques have been employed to improve the efficiency of the code is described. For the case of polychromatic excitation in a direct excitation energy-dispersive (ED) XRF instrument, experimentally collected ED-XRF spectra are compared with simulated spectral distributions. Applications of the software in the field of quantitative analysis and thickness estimation of samples of intermediate thickness illustrate the potential of the method. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
A1993KY21500006 |
Publication Date |
2002-07-25 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0584-8547; 0038-6987 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
|
Times cited |
|
Open Access |
|
Notes |
|
Approved |
no |
Call Number |
UA @ admin @ c:irua:6118 |
Serial |
5632 |
Permanent link to this record |