|
“A temperature study of mixed AgBr-AgBrI tabular crystals”. Goessens C, Schryvers D, van Landuyt J, Geuens I, Gijbels R, Jacob W, de Keyzer R Hawaii, page 70 (1995).
Keywords: H1 Book chapter; Electron microscopy for materials research (EMAT); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 3
|
|
|
“Classical atomic bilayers”. Peeters FM, Partoens B, Schweigert VA, Schweigert IV Plenum Press, New York, page 523 (1998).
Keywords: H1 Book chapter; Condensed Matter Theory (CMT)
|
|
|
“Terahertz absorption window in bilayer graphene”. Dong HM, Qin H, Zhang J, Peeters FM, Xu W Ieee, New York, N.Y., page 247 (2009).
Abstract: We present a detailed theoretical study of terahertz (THz) optical absorption in bilayer graphene. Considering an air/graphene/dielectric-wafer system, we find that there is an absorption window in the range 3 similar to 30 THz. Such an absorption window is induced by different transition energies required for inter- and intra-band optical absorption in the presence of the Pauli blockade effect. As a result, the position and width of this THz absorption window depend sensitively on temperature and carrier density of the system. These results are pertinent to the applications of recently developed graphene systems as novel optoelectronic devices such as THz photo-detectors.
Keywords: H1 Book chapter; Condensed Matter Theory (CMT)
|
|
|
“Tuning the superconducting properties of nanomaterials”. Croitoru MD, Shanenko AA, Peeters FM Springer, Dordrecht, page 1 (2009).
Abstract: Electron continement and its effect on the superconducting-to-normal phase transition driven by a magentic field and/or a current is studied in nanowires. Our investigation is based on a self-consistent numerical solution of the Bogoliubov-de Gennes equations. We find that in a parallel magneitc field and/or in the presence of a supercurrent the transition from the superconducting to the normal phase occurs as a cascade of discontinuous jumps in the superconducting order parameter for diameters D < 10 divided by 15 nm at T = 0. The critical magentic field exhibits quantum-size oscillations with pronounced resonant enhancements as a function of the wire radius.
Keywords: H1 Book chapter; Condensed Matter Theory (CMT); Electron microscopy for materials research (EMAT)
DOI: 10.1007/978-90-481-3120-4_1
|
|
|
“Glow discharge optical spectroscopy and mass spectrometry”. Bogaerts A John Wiley & Sons, Chichester, page 1 (2016).
Abstract: Atomic Spectroscopy Optical (atomic absorption spectroscopy, AAS; atomic emission spectroscopy, AES; atomic fluorescence spectroscopy, AFS; and optogalvanic spectroscopy) and mass spectrometric (magnetic sector, quadrupole mass analyzer, QMA; quadrupole ion trap, QIT; Fourier transform ion cyclotron resonance, FTICR; and time-of-flight, TOF) instrumentation are well suited for coupling to the glow discharge (GD). The GD is a relatively simple device. A potential gradient (500–1500 V) is applied between an anode and a cathode. In most cases, the sample is also the cathode. A noble gas (mostly Ar) is introduced into the discharge region before power initiation. When a potential is applied, electrons are accelerated toward the anode. As these electrons accelerate, they collide with gas atoms. A fraction of these collisions are of sufficient energy to remove an electron from a support gas atom, forming an ion. These ions are, in turn, accelerated toward the cathode. These ions impinge on the surface of the cathode, sputtering sample atoms from the surface. Sputtered atoms that do not redeposit on the surface diffuse into the excitation/ionization regions of the plasma where they can undergo excitation and/or ionization via a number of collisional processes, and the photons or ions created in this way can be detected with optical emission spectroscopy or mass spectrometry. GD sources offer a number of distinct advantages that make them well suited for specific types of analyses. These sources afford direct analysis of solid samples, thus minimizing the sample preparation required for analysis. The nature of the plasma also provides mutually exclusive atomization and excitation processes that help to minimize the matrix effects that plague so many other elemental techniques. In recent years, there is also increasing interest for using GD sources for liquid and gas analyses. In this article, first, the principles of operation of the GD plasma are reviewed, with an emphasis on how those principles relate to optical spectroscopy and mass spectrometry. Basic applications of the GD techniques are considered next. These include bulk analysis, surface analysis, and the analysis of solution and gaseous samples. The requirements necessary to obtain optical information are addressed following the analytical applications. This article focuses on the instrumentation needed to make optical measurements using the GD as an atomization/excitation source. Finally, mass spectrometric instrumentation and interfaces are addressed as they pertain to the use of a GD plasma as an ion source. GD sources provide analytically useful gas-phase species from solid samples. These sources can be interfaced with a variety of spectroscopic and spectrometric instruments for both quantitative and qualitative analyses.
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Fundamentals of Focal Series Inline Electron Holography”. Lubk A, Vogel K, Wolf D, Krehl J, Röder F, Clark L, Guzzinati G, Verbeeck J Advances in imaging and electron physics
T2 – Advances in imaging and electron physics / Hawkes, P.W. [edit.]. Elsevier BV, page 105 (2016).
Keywords: H1 Book chapter; Electron microscopy for materials research (EMAT)
DOI: 10.1016/bs.aiep.2016.08.003
|
|
|
“Modeling for a Better Understanding of Plasma-Based CO2 Conversion”. Bogaerts A, Snoeckx R, Trenchev G, Wang W In: Britun N, Silva T (eds) Plasma Chemistry and Gas Conversion. IntechOpen, Rijeka (2018).
Abstract: This chapter discusses modeling efforts for plasma-based CO2 conversion, which are needed to obtain better insight in the underlying mechanisms, in order to improve this application. We will discuss two types of (complementary) modeling efforts that are most relevant, that is, (i) modeling of the detailed plasma chemistry by zero-dimensional (0D) chemical kinetic models and (ii) modeling of reactor design, by 2D or 3D fluid dynamics models. By showing some characteristic calculation results of both models, for CO2 splitting and in combination with a H-source, and for packed bed DBD and gliding arc plasma, we can illustrate the type of information they can provide.
Keywords: H1 Book Chapter; Plasma, laser ablation and surface modeling Antwerp (PLASMANT) ;
DOI: 10.5772/intechopen.80436
|
|
|
“Advanced TEM studies of martensite and related phase transformations”. Schryvers D s.l., page 947 (1999).
Keywords: H1 Book chapter; Electron microscopy for materials research (EMAT)
|
|
|
“Anion ordering in fluorinated La2CuO4”. Hadermann J, Abakumov AM, Van Tendeloo G, Shpanchenko RV, Oleinikov PN, Antipov EV s.l., page 133 (1999).
Keywords: H1 Book chapter; Electron microscopy for materials research (EMAT)
|
|
|
“Capabilities of TOF-SIMS to study the influence of different oxidation conditions on metal contamination redistribution”. de Witte H, de Gendt S, Douglas M, Conard T, Kenis K, Mertens PW, Vandervorst W, Gijbels R s.n., Leuven, page 147 (1999).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Computer simulations of laser ablation, plume expansion and plasma formation”. Bogaerts A, Aghaei M, Autrique D, Lindner H, Chen Z, Wendelen W Trans Tech, Aedermannsdorf, page 1 (2011).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 8
DOI: 10.4028/www.scientific.net/AMR.227.1
|
|
|
“Decomposition phenomena in Ni-Mn-Ti austenite”. Schryvers D, Seo JW, Richard O, Vermeulen W, Potapov P s.l., page 887 (1999).
Keywords: H1 Book chapter; Electron microscopy for materials research (EMAT)
|
|
|
“Determination of the silver sulphide cluster size distribution via computer simulations”. Charlier E, Gijbels R, Van Doorselaer M, De Keyzer R page 85 (2000).
Abstract: Addition of a labile sulphur donor to light sensitive silver halide microcrystals results in the formation of a distribution of silver sulphide clusters on the crystal surface. These silver sulphide clusters enhance the efficiency of image formation during the photographic process. Their activity towards the capturing of light photons, however, is very critical to their size (aggregation number) and concentration. By incorporating gold ions into silver sulphide clusters it was possible to monitor the size distribution by measuring the amount of gold reacted. From these experiments, no evidence was found for aggregation of the reacted sulphur entities on the surface. The uptake of gold ions at different sulphur concentrations could well be fitted with a simulated size distribution when a catalyzed deposition of sulphur was assumed, with a reactivity of the surface equal to 1.0 % for the microcrystals studied. From a simulation of the silver sulphide cluster size distribution a correlation could also be found between increasing aggregation numbers and the absorption at increasing wavelengths in diffuse reflectance spectroscopy.
Keywords: H1 Book chapter; Engineering sciences. Technology; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Electron microscopy, nanoscopy, and scanning micro- and nanoanalysis”. Oleshko VP, Gijbels R, Amelinckx S Wiley, Chichester, page 1 (2013).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Enhanced stability against oxidation due to 2D self-organisation of hcp cobalt nanocrystals”. Lisiecki I, Turner S, Bals S, Pileni MP, Van Tendeloo G Springer, Berlin, page 273 (2008).
Keywords: H1 Book chapter; Electron microscopy for materials research (EMAT)
|
|
|
“Excitons in single and vertically coupled type II quantum dots in high magnetic fields”. Peeters FM, Janssens KL, Partoens B s.l., page 117 (2003).
Keywords: H1 Book chapter; Condensed Matter Theory (CMT)
|
|
|
“Glow discharge optical spectroscopy and mass spectrometry”. Steiner RE, Barshick CM, Bogaerts A Wiley, Chichester, page 1 (2009).
Abstract: Optical (atomic absorption spectroscopy, AAS; atomic emission spectroscopy, AES; atomic fluorescence spectroscopy, AFS; and optogalvanic spectroscopy) and mass spectrometric (magnetic sector, quadrupolemass analyzer, QMA; quadrupole ion trap, QIT; Fourier transform ion cyclotron resonance, FTICR; and time-of-flight, TOF) instrumentation are well suited for coupling to the glow discharge (GD). The GD is a relatively simple device. A potential gradient (5001500 V) is applied between an anode and a cathode. In most cases, the sample is also the cathode. A noble gas (e.g. Ar, Ne, and Xe) is introduced into the discharge region before power initiation. When a potential is applied, electrons are accelerated toward the anode. As these electrons accelerate, they collide with gas atoms. A fraction of these collisions are of sufficient energy to remove an electron from a support gas atom, forming an ion. These ions are, in turn, accelerated toward the cathode. These ions impinge on the surface of the cathode, sputtering sample atoms from the surface. Sputtered atoms that do not redeposit on the surface diffuse into the excitation/ionization regions of the plasma where they can undergo excitation and/or ionization via a number of collisional processes. GD sources offer a number of distinct advantages that make them well suited for specific types of analyses. These sources afford direct analysis of solid samples, thus minimizing the sample preparation required for analysis. The nature of the plasma also provides mutually exclusive atomization and excitation processes that help to minimize the matrix effects that plague so many other elemental techniques. Unfortunately, the GD source functions optimally in a dry environment, making analysis of solutions more difficult. These sources also suffer from difficulties associated with analyzing nonconductingsamples. In this article, first, the principles of operation of the GD plasma are reviewed, with an emphasis on how those principles relate to optical spectroscopy and mass spectrometry. Basic applications of the GD techniques are considered next. These include bulk analysis, surface analysis, and the analysis of solution samples. The requirements necessary to obtain optical information are addressed following the analytical applications. This section focuses on the instrumentation needed to make optical measurements using the GD as an atomization/excitation source. Finally, mass spectrometric instrumentation and interfaces are addressed as they pertain to the use of a GD plasma as an ion source. GDsources provide analytically useful gas-phase species from solid samples. These sources can be interfaced with avariety of spectroscopic and spectrometric instruments for both quantitative and qualitative analysis.
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“High-resolution visualization techniques : structural aspects”. Schryvers D, Van Aert S Springer, Berlin, page 135 (2012).
Keywords: H1 Book chapter; Electron microscopy for materials research (EMAT)
|
|
|
“Hole band engineering in self-assembled quantum dots and molecules”. Peeters FM, Tadić M, Janssens KL, Partoens B s.l., page 191 (2004).
Keywords: H1 Book chapter; Condensed Matter Theory (CMT)
|
|
|
“Investigation of the electron distribution functions in low pressure electron cyclotron resonance discharges”. Kaganovich I, Misina M, Bogaerts A, Gijbels R Kluwer Academic, Dordrecht, page 543 (1999).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“The local structure of YBCO based materials by TEM”. Van Tendeloo G, Lebedev OI, Verbist K, Abakumov AM, Shpanchenko RV, Antipov EV, Blank DHA Kluwer Academic, Dordrecht, page 11 (1999).
Keywords: H1 Book chapter; Electron microscopy for materials research (EMAT)
|
|
|
“Magneto-optics of shallow impurities in superlattices”. Peeters FM, Shi JM, Devreese JT Kluwer, Dordrecht, page 221 (1993).
Keywords: H1 Book chapter; Condensed Matter Theory (CMT); Theory of quantum systems and complex systems
Times cited: 3
|
|
|
“Modeling aspects of plasma-enhanced chemical vapor deposition of carbon-based materials”. Neyts E, Mao M, Eckert M, Bogaerts A CRC Press, Boca Raton, Fla, page 245 (2012).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Modeling network for argon glow discharges: the output cannot be better than the input”. Bogaerts A, Gijbels R American Institute of Physics, Melville, N.Y., page 49 (2000).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 1
|
|
|
“Modeling of the magnetron discharge”. Bogaerts A, Kolev I, Buyle G Springer, Berlin, page 61 (2008).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Molecular structure, crystal field and orientational order in solid C60”. Lamoen D, Michel KH s.l., page 183 (1994).
Keywords: H1 Book chapter; Condensed Matter Theory (CMT)
|
|
|
“A new method to calculate leakage current and its applications for sub-45nm MOSFETs”. Lujan GS, Magnus W, Soree B, Pourghaderi MA, Veloso A, van Dal MJH, Lauwers A, Kubicek S, De Gendt S, Heyns M, De Meyer K, Solid-State Device Research (ESSDERC), European Conference
T2 – ESSDERC 2005 : proceedings of 35th European Solid-State Device Research Conference, September 12-16, 2005, Grenoble, France. Ieee, S.l., page 489 (2005).
Abstract: This paper proposes a new quantum mechanical model for the calculation of leakage currents. The model incorporates both variational calculus and the transfer matrix method to compute the subband energies and the life times of the inversion layer states. The use of variational calculus simplifies the subband energy calculation due to the analytical firm of the wave functions, which offers an attractive perspective towards the calculation of the electron mobility in the channel. The model can be extended to high-k dielectrics with several layers. Good agreement between experimental data and simulation results is obtained for metal gate capacitors.
Keywords: H1 Book chapter; Condensed Matter Theory (CMT)
DOI: 10.1109/ESSDER.2005.1546691
|
|
|
“Polarity-dependent vortex pinning and spontaneous vortex-antivortex structures in superconductor/ferromagnet hybrids”. Bending SJ, Milošević MV, Moshchalkov VV Springer, Berlin, page 299 (2010).
Keywords: H1 Book chapter; Condensed Matter Theory (CMT)
|
|
|
“Scanning microanalysis”. Oleshko V, Gijbels R Wiley-VCH, Weinheim, page 427 (1997).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“SIMS/TOF-SIMS study of microparticles: surface analysis, imaging and quantification”. Gijbels R, Verlinden G, Geuens I London Institute of Physics, Bristol, page 331 (2000).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|