|
Records |
Links |
|
Author |
Bugani, S.; Modugno, F.; Lucejko, J.J.; Giachi, G.; Cagno, S.; Cloetens, P.; Janssens, K.; Morselli, L. |
|
|
Title |
Study on the impregnation of archaeological waterlogged wood with consolidation treatments using synchrotron radiation microtomography |
Type |
A1 Journal article |
|
Year |
2009 |
Publication |
Analytical and bioanalytical chemistry |
Abbreviated Journal |
Anal Bioanal Chem |
|
|
Volume |
395 |
Issue |
7 |
Pages |
1977-1985 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
In favourable conditions of low temperature and low oxygen concentration, archaeological waterlogged wooden artefacts, such as shipwrecks, can survive with a good state of preservation. Nevertheless, anaerobic bacteria can considerably degrade waterlogged wooden objects with a significant loss in polysaccharidic components. Due to these decay processes, wood porosity and water content increase under ageing. In such conditions, the conservation treatments of archaeological wooden artefacts often involve the replacement of water with substances which fill the cavities and help to prevent collapse and stress during drying. The treatments are very often expensive and technically difficult, and their effectiveness very much depends on the chemical and physical characteristics of the substances used for impregnation. Also important are the degree of cavity-filling, penetration depth and distribution in the structure of the wood. In this study, the distribution in wood cavities of some mixtures based on polyethylene glycols and colophony, used for the conservation of waterlogged archaeological wood, was investigated using synchrotron radiation X-ray computed microtomography (SR-A mu CT). This non-destructive imaging technique was useful for the study of the degraded waterlogged wood and enabled us to visualise the morphology of the wood and the distribution of the materials used in the wood treatments. The study has shown how deposition is strictly related to the dimension of the wooden cavities. The work is currently proceeding with the comparison of synchrotron observations with the data of the solutions viscosity and with those of the properties imparted to the wood by the treatments. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000272017000005 |
Publication Date |
2009-09-16 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1618-2642 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
3.431 |
Times cited |
30 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 3.431; 2009 IF: 3.480 |
|
|
Call Number |
UA @ admin @ c:irua:94493 |
Serial |
5853 |
|
Permanent link to this record |
|
|
|
|
Author |
Moro, G.; Barich, H.; Driesen, K.; Montiel, N.F.; Neven, L.; Mendonca, C.D.; Thiruvottriyur Shanmugam, S.; Daems, E.; De Wael, K. |
|
|
Title |
Unlocking the full power of electrochemical fingerprinting for on-site sensing applications |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Analytical And Bioanalytical Chemistry |
Abbreviated Journal |
Anal Bioanal Chem |
|
|
Volume |
|
Issue |
|
Pages |
1-14 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Electrochemical sensing for the semi-quantitative detection of biomarkers, drugs, environmental contaminants, food additives, etc. shows promising results in point-of-care diagnostics and on-site monitoring. More specifically, electrochemical fingerprint (EF)-based sensing strategies are considered an inviting approach for the on-site detection of low molecular weight molecules. The fast growth of electrochemical sensors requires defining the concept of direct electrochemical fingerprinting in sensing. The EF can be defined as the unique electrochemical signal or pattern, mostly recorded by voltammetric techniques, specific for a certain molecule that can be used for its quantitative or semi-quantitative identification in a given analytical context with specified circumstances. The performance of EF-based sensors can be enhanced by considering multiple features of the signal (i.e., oxidation or reduction patterns), in combination with statistical data analysis or sample pretreatments or by including electrode surface modifiers to enrich the EF. In this manuscript, some examples of EF-based sensors, strategies to improve their performances, and open challenges are discussed to unlock the full power of electrochemical fingerprinting for on-site sensing applications. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000523396300002 |
Publication Date |
2020-04-04 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1618-2642 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
4.3 |
Times cited |
3 |
Open Access |
|
|
|
Notes |
; The presented review is the result of a concerted effort and fruitful discussions among enthusiastic, young, and (for the occasion) female researchers of the AXES research group, each of them with specific expertise and background, under the guidance of the corresponding author. The authors acknowledge FWO-Flanders, BOF-UA, IOF-UA, FAPESP and EU for funding. ; |
Approved |
Most recent IF: 4.3; 2020 IF: 3.431 |
|
|
Call Number |
UA @ admin @ c:irua:168563 |
Serial |
6647 |
|
Permanent link to this record |
|
|
|
|
Author |
Swaenen, M.; Stefaniak, E.A.; Frost, R.; Worobiec, A.; Van Grieken, R. |
|
|
Title |
Investigation of inclusions trapped inside Libyan desert glass by Raman microscopy |
Type |
A1 Journal article |
|
Year |
2010 |
Publication |
Analytical and bioanalytical chemistry |
Abbreviated Journal |
|
|
|
Volume |
397 |
Issue |
7 |
Pages |
2659-2665 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP) |
|
|
Abstract |
Several specimens of Libyan desert glass (LDG), an enigmatic natural glass from Egypt, were subjected to investigation by micro-Raman spectroscopy. The spectra of inclusions inside the LDG samples were successfully measured through the layers of glass and the mineral species were identified on this basis. The presence of cristobalite as typical for high-temperature melt products was confirmed, together with co-existing quartz. TiO2 was determined in two polymorphic species rutile and anatase. Micro-Raman spectroscopy proved also the presence of minerals unusual for high-temperature glasses such as anhydrite and aragonite. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000280122100004 |
Publication Date |
2010-01-26 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1618-2642; 1618-2650 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:83276 |
Serial |
8125 |
|
Permanent link to this record |
|
|
|
|
Author |
Avigo, D.; Godoi, A.F.L.; Janissek, P.R.; Makarovska, Y.; Krata, A.; Potgieter-Vermaak, S.; Alfoldy, B.; Van Grieken, R.; Godoi, R.H.M. |
|
|
Title |
Particulate matter analysis at elementary schools in Curitiba, Brazil |
Type |
A1 Journal article |
|
Year |
2008 |
Publication |
Analytical and bioanalytical chemistry |
Abbreviated Journal |
|
|
|
Volume |
391 |
Issue |
4 |
Pages |
1459-1468 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000256088700043 |
Publication Date |
2008-03-24 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1618-2642; 1618-2650 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:68797 |
Serial |
8360 |
|
Permanent link to this record |
|
|
|
|
Author |
Cabal Rodríguez, A.E.; Leyva Pernia, D.; Schalm, O.; van Espen, P.J.M. |
|
|
Title |
Possibilities of energy-resolved X-ray radiography for the investigation of paintings |
Type |
A1 Journal article |
|
Year |
2012 |
Publication |
Analytical and bioanalytical chemistry |
Abbreviated Journal |
|
|
|
Volume |
402 |
Issue |
4 |
Pages |
1471-1480 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
X-ray radiographic images of paintings often show little or no contrast. In order to increase the contrast in radiographic images we measured the X-ray spectrum of a low power X-ray tube, after passing through the painting, with a high energy-resolution SDD detector. To obtain images, the detector is collimated with a 400 mu m diameter pinhole and the painting was moved through the beam in the x and y-direction using a dwell time of a few seconds per pixel. The data obtained consists of a data cube of, typically, 200 x 200 pixels and a 512-channel X-ray spectrum for each pixel, spanning the energy range from 0 to 40 keV. Having the absorbance spectrum available for each pixel, we are able, a posteriori, to produce images by edge subtraction for any given element. In this way high contrast, element-specific, images can be obtained. Because of the high energy-resolution a much simpler edge subtraction algorithm can be applied. We also used principal-component imaging to obtain, in a more automated way, images with high contrast. Some of these images can easily be attributed to specific elements. It turns out that preprocessing of the spectral data is crucial for the success of the multivariate image processing. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000299842000008 |
Publication Date |
2011-07-14 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1618-2642; 1618-2650 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:96200 |
Serial |
8394 |
|
Permanent link to this record |
|
|
|
|
Author |
Dillen, A.; Vandezande, W.; Daems, D.; Lammertyn, J. |
|
|
Title |
Unraveling the effect of the aptamer complementary element on the performance of duplexed aptamers : a thermodynamic study |
Type |
A1 Journal article |
|
Year |
2021 |
Publication |
Analytical And Bioanalytical Chemistry |
Abbreviated Journal |
Anal Bioanal Chem |
|
|
Volume |
413 |
Issue |
19 |
Pages |
4739-4750 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Duplexed aptamers (DAs) are widespread aptasensor formats that simultaneously recognize and signal the concentration of target molecules. They are composed of an aptamer and aptamer complementary element (ACE) which consists of a short oligonucleotide that partially inhibits the aptamer sequence. Although the design principles to engineer DAs are straightforward, the tailored development of DAs for a particular target is currently based on trial and error due to limited knowledge of how the ACE sequence affects the final performance of DA biosensors. Therefore, we have established a thermodynamic model describing the influence of the ACE on the performance of DAs applied in equilibrium assays and demonstrated that this relationship can be described by the binding strength between the aptamer and ACE. To validate our theoretical findings, the model was applied to the 29-mer anti-thrombin aptamer as a case study, and an experimental relation between the aptamer-ACE binding strength and performance of DAs was established. The obtained results indicated that our proposed model could accurately describe the effect of the ACE sequence on the performance of the established DAs for thrombin detection, applied for equilibrium assays. Furthermore, to characterize the binding strength between the aptamer and ACEs evaluated in this work, a set of fitting equations was derived which enables thermodynamic characterization of DNA-based interactions through thermal denaturation experiments, thereby overcoming the limitations of current predictive software and chemical denaturation experiments. Altogether, this work encourages the development, characterization, and use of DAs in the field of biosensing. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000659366300001 |
Publication Date |
2021-06-10 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1618-2642; 1618-2650 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
3.431 |
Times cited |
|
Open Access |
Not_Open_Access |
|
|
Notes |
|
Approved |
Most recent IF: 3.431 |
|
|
Call Number |
UA @ admin @ c:irua:179163 |
Serial |
8713 |
|
Permanent link to this record |
|
|
|
|
Author |
van Grieken, R.; Gijbels, R.; Speecke, A.; Hoste, J. |
|
|
Title |
The determination of silicon in steel by 14-mev neutron activation analysis |
Type |
A1 Journal article |
|
Year |
1968 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
Anal Chim Acta |
|
|
Volume |
43 |
Issue |
|
Pages |
199-209 |
|
|
Keywords |
A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
A fast (25 min) non-destructive determination of silicon in steel by 14-MeV neutron activation is described. The 1.78-MeV 28Al activity, induced by the reaction 28Si(n,p)28Al, is counted on a NaI(Tl) detector. An oxygen flux monitor is used to normalise to the same neutron flux. Two methods are described to correct for the 56Mn activity (2.58 h), induced into the iron matrix via 56Fe(n,p)56Mn. Nuclear interferences of phosphorus and aluminium have been examined. Special attention has been paid to stainless steels. A sensitivity of 0.02 to 0.05% of silicon is obtained. The precision is 2 to 3% for steels containing above 1% silicon, and 7% for 0.1% of silicon. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
|
|
Language |
|
Wos |
A1968C007600004 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
4.513 |
Times cited |
19 |
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ lucian @ c:irua:116357 |
Serial |
673 |
|
Permanent link to this record |
|
|
|
|
Author |
van Grieken, R.; Gijbels, R.; Speecke, A.; Hoste, J. |
|
|
Title |
Internal standard activation analysis of silicon in steel |
Type |
A1 Journal article |
|
Year |
1968 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
Anal Chim Acta |
|
|
Volume |
43 |
Issue |
|
Pages |
381-395 |
|
|
Keywords |
A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Non-destructive 14-MeV neutron activation analysis for silicon in steel has been applied with 56Mn as internal standard.56Mn is formed from the iron matrix via the 56Fe(n,p)56Mn reaction. Several methods of internal standardisation via56Mn are discussed. The 0.84-MeV photopeak of 56Mn is recommended if steel samples of about the same composition are to be analysed. Chemically analysed steel samples are used as silicon standards. A precision of 0.7% was obtained for an analysis plus standardisation time of 13 min. Special attention was paid to interferences produced by concentration changes of impurity elements. Several possible sources of errors were investigated. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
|
|
Language |
|
Wos |
A1968C185100003 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
4.513 |
Times cited |
14 |
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ lucian @ c:irua:116358 |
Serial |
1701 |
|
Permanent link to this record |
|
|
|
|
Author |
Struyf, H.; van Roy, W.; van Vaeck, L.; van Grieken, R.; Gijbels, R.; Caravatti, P. |
|
|
Title |
Laser microprobe Fourier transform mass spectrometer with external ion source for organic and inorganic microanalysis |
Type |
A1 Journal article |
|
Year |
1993 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
Anal Chim Acta |
|
|
Volume |
283 |
Issue |
|
Pages |
139-151 |
|
|
Keywords |
A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
|
|
Language |
|
Wos |
A1993MK02800013 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
4.513 |
Times cited |
17 |
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ lucian @ c:irua:6141 |
Serial |
1793 |
|
Permanent link to this record |
|
|
|
|
Author |
Vandecasteele, C.; van Grieken, R.; Gijbels, R.; Speecke, A. |
|
|
Title |
Systematic errors in 14-MeV neutron activation analysis for oxygen : part 1 : neutron and γ-ray attenuation effects |
Type |
A1 Journal article |
|
Year |
1973 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
Anal Chim Acta |
|
|
Volume |
64 |
Issue |
2 |
Pages |
187-196 |
|
|
Keywords |
A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
A detailed account is given of neutron and γ-ray attenuation effects in 14-MeV neutron activation analysis of oxygen. Appropriate neutron cross-section values have been determined in two different ways and compared with literature values. It appears that the attenuation process is best described in terms of nonelastic scattering cross-sections. It is also shown that the narrow beam total γ-ray attenuation coefficients at 6 MeV, given in the literature are suitable for correction purposes if 16N γ-rays are counted with a window of 4.56.5 MeV. Attention was paid to the contribution of β-rays when the 16N activity is counted in this energy interval with a NaI(Tl) detector. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
|
|
Language |
|
Wos |
A1973P353000003 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
4.513 |
Times cited |
11 |
Open Access |
|
|
|
Notes |
|
Approved |
CHEMISTRY, PHYSICAL 54/144 Q2 # PHYSICS, ATOMIC, MOLECULAR & CHEMICAL 9/35 Q2 # |
|
|
Call Number |
UA @ lucian @ c:irua:116363 |
Serial |
3464 |
|
Permanent link to this record |
|
|
|
|
Author |
Vandecasteele, C.; van Grieken, R.; Gijbels, R.; Speecke, A. |
|
|
Title |
Systematic errors in 14-MeV neutron activation analysis for oxygen : part 2 : a general standardization method for the determination of oxygen |
Type |
A1 Journal article |
|
Year |
1973 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
Anal Chim Acta |
|
|
Volume |
65 |
Issue |
1 |
Pages |
1-17 |
|
|
Keywords |
A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
A general standardization method is described for the determination of oxygen in solid samples via the 16O(n,p)16N reaction. Two systems of flux monitoring are considered: the sample versus standard comparator method and BF3 monitoring. The average flux in sample and standard, fast neutron shielding, fast neutron scattering, absorption of fast neutrons, absorption of 16N γ-rays and counting efficiency of sample and standard are considered. The influence of the target diameter on the obtained correction factors has also been studied. Total achievable accuracy is believed to be about 1%. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
|
|
Language |
|
Wos |
A1973Q019300001 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
4.513 |
Times cited |
12 |
Open Access |
|
|
|
Notes |
|
Approved |
|
|
|
Call Number |
UA @ lucian @ c:irua:116364 |
Serial |
3465 |
|
Permanent link to this record |
|
|
|
|
Author |
Janssens, K.; van Espen, P. |
|
|
Title |
Evaluation of energy-dispersive x-ray-spectra with the aid of expert systems |
Type |
A1 Journal article |
|
Year |
1986 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
|
|
|
Volume |
191 |
Issue |
|
Pages |
169-180 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1986H681700015 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:149780 |
Serial |
5612 |
|
Permanent link to this record |
|
|
|
|
Author |
Janssens, K.; van Espen, P. |
|
|
Title |
Implementation of an expert system for the qualitative interpretation of x-ray-fluorescence spectra |
Type |
A1 Journal article |
|
Year |
1986 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
|
|
|
Volume |
184 |
Issue |
|
Pages |
117-132 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1986D964700010 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:149782 |
Serial |
5655 |
|
Permanent link to this record |
|
|
|
|
Author |
Padilla, R.; Schalm, O.; Janssens, K.; Arrazcaeta, R.; van Espen, P. |
|
|
Title |
Microanalytical characterization of surface decoration in Majolica pottery |
Type |
A1 Journal article |
|
Year |
2005 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
Anal Chim Acta |
|
|
Volume |
535 |
Issue |
1-2 |
Pages |
201-211 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000228194200025 |
Publication Date |
2005-01-15 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
4.95 |
Times cited |
20 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 4.95; 2005 IF: 2.760 |
|
|
Call Number |
UA @ admin @ c:irua:52143 |
Serial |
5722 |
|
Permanent link to this record |
|
|
|
|
Author |
Adams, F.; Adriaens, A.; Berghmans, P.; Janssens, K. |
|
|
Title |
Surface microanalysis |
Type |
A1 Journal article |
|
Year |
1993 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
|
|
|
Volume |
283 |
Issue |
|
Pages |
19-34 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1993MK02800003 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:6106 |
Serial |
5856 |
|
Permanent link to this record |
|
|
|
|
Author |
Janssens, K.; Vincze, L.; Adams, F.; Jones, K.W. |
|
|
Title |
Synchrotron radiation-induced X-ray microanalysis |
Type |
A1 Journal article |
|
Year |
1993 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
|
|
|
Volume |
283 |
Issue |
|
Pages |
98-119 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1993MK02800009 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:6107 |
Serial |
5865 |
|
Permanent link to this record |
|
|
|
|
Author |
Komy, Z.; Roekens, E.; Van Grieken, R. |
|
|
Title |
Analysis of rain water by differential-pulse stripping voltammetry in nitric acid medium |
Type |
A1 Journal article |
|
Year |
1988 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
|
|
|
Volume |
204 |
Issue |
|
Pages |
179-187 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Differential-pulse anodic stripping voltammetry is applied to determine cadmium, lead and copper in rain water acidified with nitric acid to pH 1.5, and zinc after partial neutralization to pH 4.5. Subsequently, cobalt and nickel are measured in the adsorptive mode after formation of their dimethylglyoximates. The effects of pH on the stripping peaks for Zn, Cd, Pb and Cu and of chloride on the stripping peak of copper are reported. Good agreement is found with d.p.s.v. determinations in hydrochloric acid medium and with a.a.s. measurements in most cases. Excellent accuracy is demonstrated; the average relative standard deviation per measurement appears to be between 12 and 22% for the overall analytical procedure for concentrations of 0.1550 μgl−1 of the various metals in the samples. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1988M945900016 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670; 1873-4324 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116449 |
Serial |
7450 |
|
Permanent link to this record |
|
|
|
|
Author |
Osán, J.; de Hoog, J.; Worobiec, A.; Ro, C.-U.; Oh, K.-Y.; Szalóki, I.; Van Grieken, R. |
|
|
Title |
Application of chemometric methods for classification of atmospheric particles based on thin-window electron probe microanalysis data |
Type |
A1 Journal article |
|
Year |
2001 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
|
|
|
Volume |
446 |
Issue |
|
Pages |
211-222 |
|
|
Keywords |
A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000172309400020 |
Publication Date |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670; 1873-4324 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:36385 |
Serial |
7468 |
|
Permanent link to this record |
|
|
|
|
Author |
Ro, C.-U.; Hoornaert, S.; Van Grieken, R. |
|
|
Title |
Assessment of homogeneity of candidate reference material at the nanogram level and investigation on representativeness of single particle analysis using electron probe X-ray microanalysis |
Type |
A1 Journal article |
|
Year |
1999 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
|
|
|
Volume |
389 |
Issue |
|
Pages |
151-160 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000080527900016 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670; 1873-4324 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:27587 |
Serial |
7506 |
|
Permanent link to this record |
|
|
|
|
Author |
Vanderborght, B.; Van Grieken, R. |
|
|
Title |
Automated evaluation of photographically recorded spark-source mass spectra |
Type |
A1 Journal article |
|
Year |
1978 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
|
|
|
Volume |
103 |
Issue |
3 |
Pages |
223-235 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
A computer routine was developed for qualitative and quantitative analysis of photographically recorded spark-source mass spectra. Particular attention is given to the case of a graphite matrix. The program starts from the line intensities (expressed as Seidel values) and isotope masses calculated from the densitometer readings by a commercially available routine. From the intensities in the different exposures (typically 15 stages), it computes the parameters for the linear parts of the density curves for each ion. Taking into account mutual interferences of multivalent ions, isotope or C-clusters, oxide, carbide and dicarbide ions, the program automatically identifies and then quantifies the elements present. The precision of the results is around 5%. Reading and complete processing of one photoplate is achieved within 23 h. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1978GD90900003 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670; 1873-4324 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:113631 |
Serial |
7538 |
|
Permanent link to this record |
|
|
|
|
Author |
Buydens, L.; van Espen, P.; Rutan, S. |
|
|
Title |
CAC-2010 : Twelfth international conference on chemometrics in analytical chemistry |
Type |
Editorial |
|
Year |
2011 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
|
|
|
Volume |
705 |
Issue |
1/2 |
Pages |
1 |
|
|
Keywords |
Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000295993900001 |
Publication Date |
2011-08-14 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670; 1873-4324 |
ISBN |
|
Additional Links |
UA library record; WoS full record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:93573 |
Serial |
7570 |
|
Permanent link to this record |
|
|
|
|
Author |
Bernard, P.C.; Van Grieken, R.E. |
|
|
Title |
Comparison and evaluation of hierarchical cluster techniques applied to automated electron probe X-ray microanalysis data |
Type |
A1 Journal article |
|
Year |
1992 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
|
|
|
Volume |
267 |
Issue |
|
Pages |
81-92 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1992JM65200009 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670; 1873-4324 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:2838 |
Serial |
7688 |
|
Permanent link to this record |
|
|
|
|
Author |
Smits, J.; Nelissen, J.; Van Grieken, R. |
|
|
Title |
Comparison of preconcentration procedures for trace metals in natural waters |
Type |
A1 Journal article |
|
Year |
1979 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
|
|
|
Volume |
111 |
Issue |
|
Pages |
215-226 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The relative merits of eight procedures for preconcentrations of trace metal ions from natural water samples and synthetic solutions are evaluated. Spikes (100 μg l−1 ) of Mn, Co, Zn, Eu, Cs and Ba and the corresponding radioactive tracers were added to batches of drinking water, estuarine water, sea water, ground water, twice-distilled water and ahumic material solution. After equilibration for 25 months, the following techniques were applied: passage through columns of Dowex Al chelating resin and ofsilylated silica gel, filtration through laminate membrane filters and chelating diethylenetriamine cellulose filters, precipitation with sodium diethyldithiocarbamate and l-(2-pyridylazo)-2-naphthol, extraction with ammonium pyrrolidinedithiocarbamate, and chelation by 8-quinolinol (oxine) followed by adsorption on activated carbon. The quantitative characteristics of these techniques and the influence of the water matrix effects are discussed, as well as the applicability for x-ray fluorescence analysis. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1979HX09300018 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670; 1873-4324 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116369 |
Serial |
7695 |
|
Permanent link to this record |
|
|
|
|
Author |
Baez, J.F.; Compton, M.; Chahrati, S.; Cánovas, R.; Blondeau, P.; Andrade, F.J. |
|
|
Title |
Controlling the mixed potential of polyelectrolyte-coated platinum electrodes for the potentiometric detection of hydrogen peroxide |
Type |
A1 Journal article |
|
Year |
2020 |
Publication |
Analytica Chimica Acta |
Abbreviated Journal |
Anal Chim Acta |
|
|
Volume |
1097 |
Issue |
|
Pages |
204-213 |
|
|
Keywords |
A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The use of a Pt electrode coated with a layer of Nafion has been described in previous works as an attractive way to perform the potentiometric detection of hydrogen peroxide. Despite of the attractive features of this approach, the nature of the non-Nernstian response of this system was not properly addressed. In this work, using a mixed potential model, the open circuit potential of the Pt electrode is shown to be under kinetic control of the oxygen reduction reaction (ORR). It is proposed that hydrogen peroxide acts as an oxygenated species that blocks free sites on the Pt surface, interfering with the ORR. Therefore, the effect of the polyelectrolyte coating can be understood in terms of the modulation of the factors that affects the kinetics of the ORR, such as an increase of the H+ concentration, minimization of the effect of the spectator species, etc. Because of the complexity and the lack of models that accurately describe systems with practical applications, this work is not intended to provide a mechanistic but rather a phenomenological view on problem. A general framework to understand the factors that affect the potentiometric response is provided. Experimental evidence showing that the use of polyelectrolyte coatings are a powerful way to control the mixed potential open new ways for the development of robust and simple potentiometric sensors. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2019-11-13 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670; 1873-4324 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
6.2 |
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 6.2; 2020 IF: 4.95 |
|
|
Call Number |
UA @ admin @ c:irua:184381 |
Serial |
7731 |
|
Permanent link to this record |
|
|
|
|
Author |
Eltayeb, M.A.H.; Van Grieken, R.E. |
|
|
Title |
Coprecipitation with aluminium hydroxide and x-ray fluorescence determination of trace metals in water |
Type |
A1 Journal article |
|
Year |
1992 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
|
|
|
Volume |
268 |
Issue |
|
Pages |
177-183 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1992JQ23300020 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670; 1873-4324 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:2840 |
Serial |
7733 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Grieken, R.; Speecke, A.; Hoste, J. |
|
|
Title |
The determination of copper in iron and steel by 14-Mev neutron activation analysis |
Type |
A1 Journal article |
|
Year |
1970 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
|
|
|
Volume |
51 |
Issue |
2 |
Pages |
151-162 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
A fast (10 min) non-destructive determination of copper in. steel and cast iron by 14-MeV neutron activation analysis is described. The 0.511-MeV annihilation radiation of62Cu (T1/2=9.8 min), induced by the reaction63Cu(n,2n)62Cu, is counted by two opposing NaI(Tl) detectors operating in coincidence. An oxygen flux monitor is used to normalise the irradiations. For high phosphorus contents, two measurements are made and the 9-min activity contribution is calculated. As the iron content of the samples is known, the use of pure iron samples allows correction for53Fe activity from the reaction54Fe(n,2n)53Fe(T1/2= 8.9 min). When the phosphorus and silicon activities are low, the procedure of counting and computing can be greatly simplified. Nuclear interferences of most common alloying and impurity elements were investigated.The precision is 23% for steels containing above 1% Cu, andCa. 10% for 0.1%Cu. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1970H034700002 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670; 1873-4324 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116360 |
Serial |
7778 |
|
Permanent link to this record |
|
|
|
|
Author |
Muia, L.M.; Van Grieken, R. |
|
|
Title |
Determination of rare earth elements in geological materials by total reflection X-ray fluorescence |
Type |
A1 Journal article |
|
Year |
1991 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
|
|
|
Volume |
251 |
Issue |
|
Pages |
177-181 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670; 1873-4324 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:663 |
Serial |
7786 |
|
Permanent link to this record |
|
|
|
|
Author |
Spolnik, Z.M.; Claes, M.; Van Grieken, R. |
|
|
Title |
Determination of trace elements in organic matrices by grazing-emission X-ray fluorescence spectrometry |
Type |
A1 Journal article |
|
Year |
1999 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
|
|
|
Volume |
401 |
Issue |
|
Pages |
293-298 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000083981600037 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670; 1873-4324 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:27586 |
Serial |
7792 |
|
Permanent link to this record |
|
|
|
|
Author |
Vos, L.; Komy, G.; Reggers, G.; Roekens, E.; Van Grieken, R. |
|
|
Title |
Determination of trace metals in rain water by differential-pulse stripping voltammetry |
Type |
A1 Journal article |
|
Year |
1986 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
|
|
|
Volume |
184 |
Issue |
|
Pages |
271-280 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Differential-pulse stripping voltammetry is applied to measure zinc, cadmium, lead and copper by anodic stripping and selenium(IV) by cathodic stripping in rain water at pH 2; subsequently, at pH 9,1, manganese is measured by anodic stripping on the same portion, and cobalt and nickel are measured in the adsorptive mode after formation of their dimethylglyoximates. The instrumental parameters are optimized. The linear ranges, mutual interferences and detection limits are studied. Excellent accuracy is demonstrated; the standard deviation is around 15% at 2.550 μg l−1 levels. The method is shown to be applicable for rain water. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1986D964700026 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670; 1873-4324 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116444 |
Serial |
7793 |
|
Permanent link to this record |
|
|
|
|
Author |
Robberecht, H.; Van Grieken, R. |
|
|
Title |
Determination of trace selenium in biological material by preconcentration and X-ray emission spectrometry |
Type |
A1 Journal article |
|
Year |
1983 |
Publication |
Analytica chimica acta |
Abbreviated Journal |
|
|
|
Volume |
147 |
Issue |
|
Pages |
113-121 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Selenium is determined in the ng g−1 to μg g−1 range in biological and environmental samples. A wet digestion procedure was optimized with respect to volatility losses and recovery yields, by using 75Se metabolically incorporated into rat organs. Selenium is preconcentrated from the digestion liquid by a two-step reduction with 4 M HCl and ascorbic acid. The colloidal selenium formed is adsorbed on activated carbon and filtered on a Nucleopore membrane for measurement by energy-dispersive x-ray fluorescence. Almost complete recovery was obtained, and the detection limit was 20 ng, corresponding to 10 ng g−1 for a 2-g sample. Biological reference materials were analyzed with satisfactory results, and the accuracy of the method was good. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1983QH42100010 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2670; 1873-4324 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116442 |
Serial |
7794 |
|
Permanent link to this record |