|   | 
Details
   web
Records
Author Spolnik, Z.M.; Claes, M.; Van Grieken, R.E.; de Bokx, P.K.; Urbach, H.P.
Title Quantification in grazing-emission X-ray fluorescence spectrometry Type A1 Journal article
Year 1999 Publication (up) Spectrochimica acta: part B : atomic spectroscopy Abbreviated Journal
Volume 54 Issue Pages 1525-1537
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000083433600019 Publication Date 2002-08-30
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0584-8547; 1873-3565 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:27589 Serial 8432
Permanent link to this record
 

 
Author Szalóki, I.; Osán, J.; Ro, C.-U.; Van Grieken, R.
Title Quantitative characterization of individual aerosol particles by thin-window electron probe microanalysis combined with iterative simulation Type A1 Journal article
Year 2000 Publication (up) Spectrochimica acta: part B : atomic spectroscopy Abbreviated Journal
Volume 55 Issue Pages 1017-1030
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000088353100031 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0584-8547; 1873-3565 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:31672 Serial 8441
Permanent link to this record
 

 
Author Godoi, R.H.M.; Potgieter-Vermaak, S.; de Hoog, J.; Kaegi, R.; Van Grieken, R.
Title Substrate selection for optimum qualitative and quantitative single atmospheric particles analysis using nano-manipulation, sequential thin-window electron probe X-ray microanalysis and micro-Raman spectrometry Type A1 Journal article
Year 2006 Publication (up) Spectrochimica acta: part B : atomic spectroscopy Abbreviated Journal
Volume 61 Issue 4 Pages 375-388
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000238887600002 Publication Date 2006-03-21
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0584-8547; 1873-3565 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:58860 Serial 8614
Permanent link to this record
 

 
Author Bekshaev, A.; Van Grieken, R.
Title Substrates with a periodic surface structure in grazing-exit X-ray microanalysis Type A1 Journal article
Year 2002 Publication (up) Spectrochimica acta: part B : atomic spectroscopy Abbreviated Journal
Volume 57 Issue Pages 865-882
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000177033500005 Publication Date 2003-02-28
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0584-8547; 1873-3565 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:39516 Serial 8615
Permanent link to this record
 

 
Author Worobiec, A.; de Hoog, J.; Osán, J.; Szalóki, I.; Ro, C.-U.; Van Grieken, R.
Title Thermal stability of beam sensitive atmospheric aerosol particles in electron probe microanalysis at liquid nitrogen temperature Type A1 Journal article
Year 2003 Publication (up) Spectrochimica acta: part B : atomic spectroscopy Abbreviated Journal
Volume 58 Issue Pages 479-496
Keywords A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000182680400008 Publication Date 2003-04-23
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0584-8547; 1873-3565 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:41220 Serial 8663
Permanent link to this record
 

 
Author Osán, J.; Kurunczi, S.; Török, S.; Van Grieken, R.
Title X-ray analysis of riverbank sediment of the Tisza (Hungary): identification of particles from a mine pollution event Type A1 Journal article
Year 2002 Publication (up) Spectrochimica acta: part B : atomic spectroscopy Abbreviated Journal
Volume 57 Issue Pages 413-422
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000175029300004 Publication Date 2002-10-15
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0584-8547; 1873-3565 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:37625 Serial 8763
Permanent link to this record
 

 
Author Darchuk, L.A.; Zaverbna, L.V.; Bebeshko, V.G.; Worobiec, A.; Stefaniak, E.A.; Van Grieken, R.
Title Infrared investigation of hard human teeth tissues exposed to various doses of ionizing radiation from the 1986 Chernobyl accident Type A1 Journal article
Year 2008 Publication (up) Spectroscopy Abbreviated Journal
Volume 22 Issue 2/3 Pages 105-111
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000256194800004 Publication Date 2012-04-29
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0712-4813 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:68796 Serial 8100
Permanent link to this record
 

 
Author Van Grieken, R.; Roekens, E.; Sweevers, H.; Vleugels, G.
Title Spectroscopy and ion chromatography to study the effects of air pollution on historical buildings Type A1 Journal article
Year 1989 Publication (up) Spectroscopy Abbreviated Journal
Volume 10 Issue Pages 70-81
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos Publication Date
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0712-4813 ISBN Additional Links UA library record
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116826 Serial 8575
Permanent link to this record
 

 
Author Potgieter-Vermaak, S.; Van Grieken, R.; Potgieter, J.H.
Title Integrated analytical techniques for the characterisation of environmental particles Type A1 Journal article
Year 2010 Publication (up) Spectroscopy Europe Abbreviated Journal
Volume 22 Issue 5 Pages 12-15
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos Publication Date
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0966-0941; 2634-2561 ISBN Additional Links UA library record
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:85517 Serial 8109
Permanent link to this record
 

 
Author Čevik, U.; Akbulut, S.; Makarovska, Y.; Van Grieken, R.
Title Polarized-beam high-energy EDXRF in geological samples Type A1 Journal article
Year 2013 Publication (up) Spectroscopy letters Abbreviated Journal
Volume 46 Issue 1 Pages 36-46
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Certified reference materials (NIST 1645, BCR 143, IAEA 7, BCR 141, NIESCRM02, and IAEA 375) were used for determining the performance of a secondary target energy-dispersive X-ray fluorescence (EDXRF) spectrometer, Epsilon 5 (PANalytical, Almelo, the Netherlands). For the evaluation of the EDXRF spectra with polarized-beam high-energy excitation, the WinAxil software package has been applied. The results showed that Epsilon 5, EDXRF spectrometry is favorable for the determination of elemental concentrations in geological samples, but the sample preparation has the largest influence on the precision. However, they presented good agreement with certified values for most of the elements.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000314018900005 Publication Date 2013-01-03
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0038-7010 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:106754 Serial 8392
Permanent link to this record
 

 
Author Verbueken, A.H.; van de Vijver, F.L.; Visser, W.J.; Van Grieken, R.E.; de Broe, M.E.
Title Laser microprobe mass analysis (LAMMA) to verify the aluminon staining of bone Type A1 Journal article
Year 1986 Publication (up) Stain technology Abbreviated Journal
Volume 61 Issue 5 Pages 287-295
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
Abstract Triammonium aurin tricarboxylate (aluminon) has been used to localize aluminum in 2 μm sections of undecalcified, methyl methacrylate embedded bone obtained from patients with terminal chronic renal failure. Aluminum appeared in four cases as bright red lines at the mineralized-bone boundary. In two cases, however, purplish lines were found and one patient showed red as well as purplish lines. Laser microprobe mass analysis (LAMMA) identified aluminum at the location of the red lines and both aluminum and iron at the purplish lines. Furthermore, both iron and aluminum were found in histiocytic bone marrow cells, which showed brownish aluminon staining. It appears that when aluminum and iron occur together, aluminon staining may yield aberrant results. This study shows that LAMMA can be used for the identification of elements sought by histochemical methods and thus permits the evaluation of their staining effects.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos Publication Date 2007-12-07
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0038-9153 ISBN Additional Links UA library record
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116764 Serial 8159
Permanent link to this record
 

 
Author Torfs, K.; Van Grieken, R.; Zezza, F.; Garcia, N.; Macri, F.
Title The cathedral of Bari, Italy: evaluation of environmental effects on stone decay phenomena Type A1 Journal article
Year 1997 Publication (up) Studies in conservation = Études de conservation Abbreviated Journal
Volume 42 Issue Pages 193-206
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000071198200001 Publication Date 2006-04-23
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:18785 Serial 7585
Permanent link to this record
 

 
Author Janssens, K.; Bogaerts, A.; van Grieken, R.
Title Colloquium Spectroscopicum Internationale 34, Antwerp, Belgium, 4-9 September 2005: preface Type Editorial
Year 2006 Publication (up) Talanta : the international journal of pure and applied analytical chemistry Abbreviated Journal Talanta
Volume 70 Issue 5 Pages 907-908
Keywords Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Abstract
Address
Corporate Author Thesis
Publisher Pergamon Place of Publication Oxford Editor
Language Wos 000242871900001 Publication Date 2006-11-01
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0039-9140; ISBN Additional Links UA library record; WoS full record
Impact Factor 4.162 Times cited Open Access
Notes Approved Most recent IF: 4.162; 2006 IF: 2.810
Call Number UA @ lucian @ c:irua:61094 Serial 392
Permanent link to this record
 

 
Author Anaf, W.; Horemans, B.; Van Grieken, R.; De Wael, K.
Title Chemical boundary conditions for the classification of aerosol particles using computer controlled electron probe microanalysis Type A1 Journal article
Year 2012 Publication (up) Talanta : the international journal of pure and applied analytical chemistry Abbreviated Journal Talanta
Volume 101 Issue Pages 420-427
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract A method for the classification of individual aerosol particles using computer controlled electron probe microanalysis is presented. It is based on chemical boundary conditions (CBC) and enables quick and easy processing of a large set of elemental concentration data (mass%), derived from the X-ray spectra of individual particles. The particles are first classified into five major classes (sea salt related, secondary inorganic, minerals, iron-rich and carbonaceous), after which advanced data mining can be performed by examining the elemental composition of particles within each class into more detail (e.g., by ternary diagrams). The CBC method is validated and evaluated by comparing its results with the output obtained with hierarchical cluster analysis (HCA) for well-known standard particles as well as real aerosol particles collected with a cascade impactor. The CBC method gives reliable results and has a major advantage compared to HCA. CBC is based on boundary conditions that are derived from chemical logical thinking and does not require a translation of a mathematical algorithm output as does HCA. Therefore, the CBC method is more objective and enables comparison between samples without intermediate steps.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000313084400061 Publication Date 2012-09-30
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0039-9140; 1873-3573 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 4.162 Times cited 3 Open Access
Notes ; ; Approved Most recent IF: 4.162; 2012 IF: 3.498
Call Number UA @ admin @ c:irua:101336 Serial 5511
Permanent link to this record
 

 
Author Kontozova-Deutsch, V.; Deutsch, F.; Bencs, L.; Krata, A.; Van Grieken, R.; De Wael, K.
Title Optimization of the ion chromatographic quantification of airborne fluoride, acetate and formate in the Metropolitan Museum of Art, New York Type A1 Journal article
Year 2011 Publication (up) Talanta : the international journal of pure and applied analytical chemistry Abbreviated Journal Talanta
Volume 86 Issue Pages 372-376
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Ion chromatographic (IC) methods have been compared in order to achieve an optimal separation of fluoride, acetate and formate under various elution conditions on two formerly introduced analytical columns (i and ii) and a novel one (iii): (i) an IonPac AS14 (250 mm × 4 mm I.D.), (ii) Allsep A-2 (150 mm × 4.6 mm I.D.), and (iii) an IC SI-50 4E (250 mm (length) × 4 mm (internal diameter – I.D.)). The IC conditions for the separation of the anions concerned were optimized on the IC SI-50 4E column. A near baseline separation of these anions was attained on the IonPac AS14, whereas the peaks of fluoride and acetate could not be resolved on the Allsep A-2. A baseline separation for the three anions was achieved on the IC SI-50 4E column, when applying an eluent mixture of 3.2 mmol/L Na2CO3 and 1.0 mmol/L NaHCO3 with a flow rate of 1.0 mL/min. The highest precision of 1.7, 3.0 and 2.8% and the best limits of detection (LODs) of 0.014, 0.22 and 0.17 mg/L for fluoride, acetate and formate, respectively, were obtained with the IC SI-50 4E column. Hence, this column was applied for the determination of the acetic and formic acid contents of air samples taken by means of passive gaseous sampling at the Metropolitan Museum of Art in New York, USA. Atmospheric concentrations of acetic and formic acid up to 1050 and 450 μg/m3, respectively, were found in non-aerated showcases of the museum. In galleries and outdoors, rather low levels of acetic and formic acid were detected with average concentrations of 50 and 10 μg/m3, respectively. The LOD data of acetate and formate on the IC SI-50 4E column correspond to around 0.5 μg/m3 for both acetic and formic acid in air samples.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000298126300048 Publication Date 2011-09-24
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0039-9140; 1873-3573 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 4.162 Times cited 19 Open Access
Notes ; The authors gratefully acknowledge the support of Marco Leona and the staff of the Metropolitan Museum of Art in New York during the sampling campaigns. The technical assistance and advice by Dr. Takashi Kotsuka and Shodex Benelux are acknowledged as well. ; Approved Most recent IF: 4.162; 2011 IF: 3.794
Call Number UA @ admin @ c:irua:92066 Serial 5762
Permanent link to this record
 

 
Author Buczyńska, A.J.; Geypens, B.; Van Grieken, R.; De Wael, K.
Title Stable carbon isotopic ratio measurement of polycyclic aromatic hydrocarbons as a tool for source identification and apportionment : a review of analytical methodologies Type A1 Journal article
Year 2013 Publication (up) Talanta : the international journal of pure and applied analytical chemistry Abbreviated Journal Talanta
Volume 105 Issue Pages 435-450
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract The measurement of the ratio of stable isotopes of carbon (13C/12C expressed as a δ13C) in the individual components of a sample may be used as a means to identify the origin of these components. This article reviews the approaches and reports on the successes and failures of source identification and apportionment of Polycyclic Aromatic Hydrocarbons (PAHs) with the use of compound-specific isotope analysis (CSIA). One of the conditions for a precise and accurate analysis of isotope ratios with the use of GC-C-IRMS is the need for well separated peaks, with no co-elutions, and reduced unresolved complex mixture (UCM). Additionally, special care needs to be taken for an investigation of possible isotope fractionation effects introduced during the analytical treatment of samples. With the above-mentioned problems in mind, this review discusses in detail and compares current laboratory methodologies, mainly in the extraction and subsequent clean-up techniques used for environmental samples (air particulate matter, soil and sediments). Sampling strategies, the use of isotopic internal standards and the ranges for precision and accuracy are also reported and discussed.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000319088500064 Publication Date 2012-10-30
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0039-9140; 1873-3573 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 4.162 Times cited 19 Open Access
Notes ; ; Approved Most recent IF: 4.162; 2013 IF: 3.511
Call Number UA @ admin @ c:irua:102091 Serial 5845
Permanent link to this record
 

 
Author Vanderstappen, M.G.; Van Grieken, R.E.
Title Co-crystallization with 1-(2-pyridylazo)-2-naphthol, and X-ray fluorescence, for trace metal analysis of water Type A1 Journal article
Year 1978 Publication (up) Talanta : the international journal of pure and applied analytical chemistry Abbreviated Journal
Volume 25 Issue 11/12 Pages 653-658
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Adding 20mg of 1-(2-pyridylazo)-2-naphthol (PAN) to a water sample at 70°, and filtering off the precipitate after cooling, gives efficient preconcentration prior to X-ray fluorescence analysis of water. Up to the capacity of about 100 μeq of PAN used, the trace metal recoveries are around 90% or higher for Cr3+, Mn2+, Ni2+, Cu2+, Zn2+, Hg2+ and Eu3+, and above 70% for many other ions. The recovery yields usually do not vary critically with pH in the neutral pH-range, and are practically independent of the sample salinity, sample volume and trace-metal concentration. Enrichment factors as high as 2 × 105 can be achieved. Counting statistics would then allow detection limits of 0.03 ppM. The blank levels in commercial PAN, however, lead to typical detection limits of about 1 ppm. The coefficient of variation is typically in the 510% range at the 10-ppM level. The accuracy and applicability of the procedure are illustrated by comparative analyses on samples of synthetic solutions, river and drinking water.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos A1978GG18200005 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0039-9140; 1873-3573 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116556 Serial 7675
Permanent link to this record
 

 
Author Kontozova-Deutsch, V.; Krata, A.; Deutsch, F.; Bencs, L.; Van Grieken, R.
Title Efficient separation of acetate and formate by ion chromatography: application to air samples in a cultural heritage environment Type A1 Journal article
Year 2008 Publication (up) Talanta : the international journal of pure and applied analytical chemistry Abbreviated Journal
Volume 75 Issue 2 Pages 418-423
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000255270700015 Publication Date 2007-11-26
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0039-9140; 1873-3573 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:67547 Serial 7854
Permanent link to this record
 

 
Author György, K.; Ajtony, Z.; van Meel, K.; Van Grieken, R.; Czitrovszky, A.; Bencs, L.
Title Fast heating induced impulse halogenation of refractory sample components in electrothermal atomic absorption spectrometry by direct injection of a liquid halogenating agent Type A1 Journal article
Year 2011 Publication (up) Talanta : the international journal of pure and applied analytical chemistry Abbreviated Journal
Volume 85 Issue 3 Pages 1253-1259
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract A novel electrothermal atomic absorption spectrometry (ETAAS) method was developed for the halogenation of refractory sample components (Er, Nd and Nb) of lithium niobate (LiNbO3) and bismuth tellurite (Bi2TeO5) optical single crystals to overcome memory effects and carry-over. For this purpose, the cleaning step of a regular graphite furnace heating program was replaced with a halogenation cycle. In this cycle, after the graphite tube cooled to room temperature, a 20 μL aliquot of liquid carbon tetrachloride (CCl4) was dispensed with a conventional autosampler into the graphite tube. The CCl4 was partially dried at 80 °C under the mini-flow (40 cm3 min−1) condition of the Ar internal furnace gas (IFG), then the residue was decomposed (pyrolyzed) by fast furnace heating at 19002100 °C under interrupted flow of the IFG. This step was followed by a clean-out stage at 2100 °C under the maximum flow of the IFG. The advantage of the present method is that it does not require any alteration to the graphite furnace gas supply system in contrast to most of the formerly introduced halogenation techniques. The effectiveness of the halogenation method was verified with the determination of Er and Nd dopants in the optical crystals. In these analyses, a sensitivity decrease was observed, which was likely due to the enhanced deterioration of the graphite tube surface. Therefore, the application of mathematical correction (resloping) of the calibration was also required. The calibration curves were linear up to 1.5 and 10 μmol L−1 for Er and Nd, respectively. Characteristic masses of 18 and 241 pg and the limit of detection (LOD) values of 0.017 and 0.27 μmol L−1 were found for Er and Nd, respectively. These LOD data correspond to 0.68 μmol mol−1 Er and 11 μmol mol−1 Nd in solid bismuth tellurite samples. The analytical results were compared with those obtained by a conventional ETAAS method and validated with X-ray fluorescence spectrometry analysis.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000294092800006 Publication Date 2011-05-27
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0039-9140; 1873-3573 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:91721 Serial 7960
Permanent link to this record
 

 
Author Robberecht, H.J.; Van Grieken, R.E.; Van den Bosch, P.A.; Deelstra, H.; vanden Berghe, D.
Title Losses of metabolically incorporated selenium in common digestion procedures for biological material Type A1 Journal article
Year 1982 Publication (up) Talanta : the international journal of pure and applied analytical chemistry Abbreviated Journal
Volume 29 Issue 11 Pages 1025-1028
Keywords A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Two common procedures for wet destruction of biological materials for subsequent determination of selenium have been investigated. Rat organs and biological fluids were endogenously labelled with 75Se to monitor losses during the procedures. Addition of nitric and perchloric acids with gradual heating up to 210° seemed to be the best method: at this temperature the labelled selenium was still recovered quantitatively, and the destruction was fast and efficient.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos A1982PP35500009 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0039-9140; 1873-3573 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116568 Serial 8186
Permanent link to this record
 

 
Author Robberecht, H.; Van Grieken, R.
Title Selenium in environmental waters : determination, speciation and concentration levels Type A1 Journal article
Year 1982 Publication (up) Talanta : the international journal of pure and applied analytical chemistry Abbreviated Journal
Volume 29 Issue 10 Pages 823-844
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract This article reviews the different methods used for the determination of selenium species in all types of environmental waters. Basic difficulties are discussed and the efficiency of the methods is explained in view of the sub-μg/1. concentration levels. Special attention is paid to preconcentration steps. Published data on speciation and concentration levels in various water samples are critically reviewed.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos A1982PK22900004 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0039-9140; 1873-3573 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:113627 Serial 8509
Permanent link to this record
 

 
Author Krata, A.; Kontozova-Deutsch, V.; Bencs, L.; Deutsch, F.; Van Grieken, R.
Title Single-run ion chromatographic separation of inorganic and low-molecular-mass organic anions under isocratic elution: application to environmental samples Type A1 Journal article
Year 2009 Publication (up) Talanta : the international journal of pure and applied analytical chemistry Abbreviated Journal
Volume 79 Issue 1 Pages 16-21
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract For the isocratic ion chromatography (IC) separation of low-molecular-mass organic acids and inorganic anions three different anion-exchange columns were studied: IonPac AS14 (9 ìm particle size), Allsep A-2 (7 ìm particle size), and IC SI-50 4E (5 ìm particle size). A complete baseline separation for all analyzed anions (i.e., F−, acetate, formate, Cl−, NO2−, Br−, NO3−, HPO42− and SO42−) in one analytical cycle of shorter than 17 min was achieved on the IC SI-50 4E column, using an eluent mixture of 3.2 mM Na2CO3 and 1.0 mM NaHCO3 with a flow rate of 1.0 mL min−1. On the IonPac AS14 column, it was possible to separate acetate from inorganic anions in one run (i.e., less than 9 min), but not formate, under the following conditions: 3.5 mM Na2CO3 plus 1.0 mM NaHCO3 with a flow rate of 1.2 mL min−1. Therefore, it was necessary to adapt a second run with a 2.0 mM Na2B4O7 solution as an eluent under a flow rate of 0.8 mL min−1 for the separation of organic ions, which considerably enlarged the analysis time. For the Allsep A-2 column, using an eluent mixture of 1.2 mM Na2CO3 plus 1.5 mM NaHCO3 with a flow rate of 1.6 mL min−1, it was possible to separate almost all anions in one run within 25 min, except the fluoride-acetate critical pair. A Certified Multianion Standard Solution PRIMUS for IC was used for the validation of the analytical methods. The lowest RSDs (less than 1%) and the best LODs (0.02, 0.2, 0.16, 0.11, 0.06, 0.05, 0.04, 0.14 and 0.09 mg L−1 for F−, Ac−, For−, Cl−, NO2−, Br−, NO3−, HPO42− and SO42−, respectively) were achieved using the IC SI-50 4E column. This column was applied for the separation of concerned ions in environmental precipitation samples such as snow, hail and rainwater.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos 000266187600004 Publication Date 2009-03-06
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0039-9140; 1873-3573 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:75475 Serial 8542
Permanent link to this record
 

 
Author Vanderborght, B.; Van Grieken, R.
Title Spark-source mass-spectrometric sensitivity factors for elements in a graphite matrix Type A1 Journal article
Year 1979 Publication (up) Talanta : the international journal of pure and applied analytical chemistry Abbreviated Journal
Volume 26 Issue 6 Pages 461-465
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Relative sensitivity factors for determination of 41 elements by spark-source mass-spectrometry have been measured. The samples were pressed into graphite electrodes and ionized with a radiofrequency spark. The mass spectra were recorded on a photoplate and the resulting data processed by a computer. Indium was used as standard and the relative sensitivity factors for both singly- and doubly-charged ions were determined with reference to the singly-charged indium ion, with an overall error of 30%. The mean analysis precision was 16%.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos A1979GX58000005 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0039-9140; 1873-3573 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:113630 Serial 8563
Permanent link to this record
 

 
Author Vanderborght, B.M.; Van Grieken, R.E.
Title Water analysis by spark-source mass-spectrometry after preconcentration on activated carbon Type A1 Journal article
Year 1980 Publication (up) Talanta : the international journal of pure and applied analytical chemistry Abbreviated Journal
Volume 27 Issue 5 Pages 417-422
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract For trace analyses of environmental waters, spark-source mass-spectrometry has been combined with a preconcentration procedure involving chelation of the dissolved trace elements with oxine and subsequent adsorption of the oxinates and naturally occurring organic and colloidal metal species onto activated carbon. The activated carbon is filtered off and ashed at low temperature. The residue is dissolved, an internal standard and pure graphite are added and, after drying, the electrodes are prepared. The photographically recorded mass spectrum is evaluated by a suitable computer routine. The error of the procedure is around 30%. While this preconcentration and analysis procedure is capable of measuring about 40 elements quantitatively, in practice 1025 trace elements are determined simultaneously above the 0.1-μg/l. detection limit, as is illustrated by analyses of drinking water, surface and ground water samples. Although a sophisticated technique, SSMS can be considered for regular panoramic survey analyses.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos A1980JR07800006 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0039-9140; 1873-3573 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116557 Serial 8746
Permanent link to this record
 

 
Author Koleleni, Y.I.A.; Van Grieken, R.
Title Analysis of biological materials from Tanzania by total reflection X-ray fluorescence (TXRF) analysis Type A3 Journal article
Year 1990 Publication (up) Tanzania journal of science Abbreviated Journal
Volume 16 Issue Pages 143-157
Keywords A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos Publication Date
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Additional Links UA library record
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116934 Serial 7442
Permanent link to this record
 

 
Author Koleleni, Y.I.A.; Van Grieken, R.
Title Aerosol composition as a function of particle size Type A3 Journal article
Year 1993 Publication (up) Tanzanian journal of science Abbreviated Journal
Volume 19 Issue Pages 49-61
Keywords A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos Publication Date
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Additional Links UA library record
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:55572 Serial 7423
Permanent link to this record
 

 
Author Artaxo, P.; Rabello, M.L.C.; Maenhaut, W.; Van Grieken, R.
Title Trace elements and individual particle analysis of atmospheric aerosols from the Antarctic peninsula Type A3 Journal article
Year 1992 Publication (up) Tellus Abbreviated Journal
Volume 44b Issue Pages 318-334
Keywords A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos Publication Date
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Additional Links UA library record
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:2845 Serial 8689
Permanent link to this record
 

 
Author Treiger, B.; Bondarenko, I.; van Espen, P.; Van Grieken, R.; Adams, F.
Title Classification of mineral particles by nonlinear mapping of electron microprobe energy-dispersive X-ray spectra Type A1 Journal article
Year 1994 Publication (up) The analyst Abbreviated Journal
Volume 119 Issue Pages 971-974
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos A1994NR76500037 Publication Date 2004-03-24
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:8918 Serial 7669
Permanent link to this record
 

 
Author Jambers, W.; de Bock, L.; Van Grieken, R.
Title Recent advances in the analysis of individual environmental particles: a review Type A1 Journal article
Year 1995 Publication (up) The analyst Abbreviated Journal
Volume 120 Issue Pages 681-692
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos A1995QP46100016 Publication Date 2004-03-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:12343 Serial 8458
Permanent link to this record
 

 
Author Vandeputte, D.F.; Jacob, W.A.; Van Grieken, R.E.
Title Influence of fixation procedures on the microanalysis of lead-induced intranuclear inclusions in rat kidney Type A1 Journal article
Year 1990 Publication (up) The journal of histochemistry and cytochemistry Abbreviated Journal
Volume 38 Issue 3 Pages 331-337
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Using Laser Microprobe Mass Analysis (LAMMA), we studied the chemical composition of lead-induced intranuclear inclusions in rat kidney tissue prepared by three different wet chemical fixation procedures for transmission electron microscopy. Fixation with glutaraldehyde-Na2S gave the same results as fixation with glutaraldehyde only: a high lead concentration could be detected. Therefore, for lead strongly bound to proteins, precipitation procedures are not essential. Post-fixation with osmium tetroxide drastically changed the composition of the inclusions: the lead concentration decreased substantially, while sodium, calcium, and barium were introduced. The osmium tetroxide fixative was found to be the source of the contamination. It also contained aluminum, and we suggest that other proteins (e.g., in neurofibrillary tangles) might be able to take up Al out of solution and that care must be exercised in interpreting the microanalytical results of osmium-fixed material. For the microanalysis of the lead inclusions, fixation with glutaraldehyde only provides a good compromise between preservation of the ultrastructure and maintenance of the element distribution.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos Publication Date 2011-04-01
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0022-1554 ISBN Additional Links UA library record
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116831 Serial 8091
Permanent link to this record