|
“Bio(inspired) strategies for the electro-sensing of β-lactam antibiotics”. Bottari F, Blust R, De Wael K, Current opinion in electrochemistry 10, 143 (2018). http://doi.org/10.1016/J.COELEC.2018.05.016
Abstract: The dire previsions of the WHO on the so-called “post-antibiotic era” and the continuous and global rise of anti-microbial resistance, spurs our research community to find better ways to fight these threats. In light of this severe threat to human health many attempts have been made to develop efficient methods to detect antibiotic residues in different streams. The use of electrochemistry seems an inviting approach for on-site and fast monitoring. In this critical review, recent developments in the field of (bio) electro-sensing of 19-lactam antibiotics will be presented, with a focus on aptamers and molecularly imprinted polymers, the two main promises of a new generation of biosensors, yet to be fulfilled.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 15
DOI: 10.1016/J.COELEC.2018.05.016
|
|
|
“Challenges in the electrochemical (bio)sensing of non-electroactive food and environmental contaminants”. Moro G, De Wael K, Moretto LM, Current opinion in electrochemistry 16, 57 (2019). http://doi.org/10.1016/J.COELEC.2019.04.019
Abstract: The electrochemical detection of non-electroactive contaminants can be successfully faced via the use of indirect detection strategies. These strategies can provide sensitive and selective responses often coupled with portable and user-friendly analytical tools. Indirect detection strategies are usually based on the change in the signal of an electroactive probe, induced by the presence of the target molecule at a modified electrode. This critical review aims at addressing the developments in indirect electro-sensing strategies for non-electroactive contaminants in food and environmental analysis in the last years (2017-2019). Emphasis is given to the strategy design, the electrode modifiers used and the feasibility of technological transfer.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 4
DOI: 10.1016/J.COELEC.2019.04.019
|
|
|
“Electrochemical strategies for the detection of forensic drugs”. Florea A, De Jong M, De Wael K, Current opinion in electrochemistry 11, 34 (2018). http://doi.org/10.1016/J.COELEC.2018.06.014
Abstract: Illicit drugs consumption and trafficking is spread worldwide and remains an increasing challenge for local authorities. Forensic drugs and their metabolites are released into wastewaters due to human excretion after illegal consumption of drugs and occasionally due to disposal of clandestine laboratory wastes into sewage systems, being recently classified as the latest group of emerging pollutants. Hence, it is essential to have efficient and accurate methods to detect these type of compounds in seized street samples, biological fluids and wastewaters in order to reduce and prevent trafficking and consumption and negative effects on aquatic systems. Electrochemical strategies offer a fast, portable, low-cost and accurate alternative to chromatographic and spectrometric methods, for the analysis of forensic drugs and metabolites in different matrices. Recent electrochemical strategies applied to the detection of illicit drugs in wastewaters, biological fluids and street samples are presented in this review, together with the impact of drug consumption on the environment.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 7
DOI: 10.1016/J.COELEC.2018.06.014
|
|
|
“Synthesis and characterization of heteroleptic rare earth double-decker complexes involving tetradiazepinoporphyrazine and phthalocyanine macrocycles”. Tarakanova EN, Tarakanov PA, Simakov AO, Furuyama T, Kobayashi N, Konev DV, Goncharova OA, Trashin SA, De Wael K, Sulimenkov IV, Filatov VV, Kozlovskiy VI, Tomilova LG, Stuzhin PA, Pushkarev VE, Dalton Transactions 50, 6245 (2021). http://doi.org/10.1039/D1DT00088H
Abstract: Reaction of (2,3,9,10,16,17,23,24-octabutylphthalocyaninato)lanthanide(iii) acetylacetonates ((Bu)PcLn(acac), 1a-c, Ln = Lu (a), Eu (b), La (c)) with a tetrakis(5,7-bis(4-tert-butylphenyl)-6H-1,4-diazepino)[2,3-b,g,l,q]porphyrazine ligand ((tBuPh)DzPzH(2), 2) produced sandwich compounds ((tBuPh)DzPz)Ln(Pc-Bu) (3a-c), which represent the first heteroleptic double-deckers incorporating both Pc and DzPz decks. A combination of high-resolution mass spectrometry, UV-Vis/NIR, MCD, and H-1 NMR spectroscopy, and square-wave voltammetry provided unambiguous characterization of target complexes 3 indicating that their spectral and electrochemical properties are generally intermediate with respect to their homoleptic relatives. Based on the data of solution-state H-1-H-1 NMR (COSY, NOESY) correlation spectroscopy supported by DFT calculations, a dimerization tendency of compounds 3 proportional to the Ln(iii) ion size was found. The spectroelectrochemical study of 3 and the corresponding homoleptic double-deckers revealed a pronounced tendency to aggregation of the one-electron oxidized forms of DzPz-containing double-decker complexes compared to homoleptic Pc(2)Ln compounds.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.029
DOI: 10.1039/D1DT00088H
|
|
|
“X-Ray Fluorescence as an analytical tool for studying the copper matrices in the collection of the Museum Plantin-Moretus”. Storme P, Fransen E, De Wael K, Caen J, De gulden passer 95, 7 (2017)
Keywords: A1 Journal article; Engineering sciences. Technology; History; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
|
|
|
“Atmosferische fluxen van zware metalen naar de Noordzee”. Otten P, Injuk J, Rojas C, Van Grieken R, De ingenieur 5, 32 (1992)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Echt of namaak? Venetiaans glas uit het oude Antwerpen”. de Raedt I, Janssens K, Veeckman J, De wetenschappelijke bibliotheek 67, 58 (1999)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Microscopic X-ray fluorescence analysis at second and third generation synchrotron sources”. Janssens K, Adams F, Debye Institute synchrotron chronicle , 9 (1997)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“NO2 verkeersmetingen in Vlaanderen door passieve bemonstering”. Potgieter-Vermaak S, Stranger M, Verlinden L, Roekens E, Van Grieken R, Die Suid-Afrikaanse tydskrif vir natuurwetenskap en tegnologie 27, 266 (2008)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Composition of individual aerosol particles in the marine boundary layer over seas of the Western Russian Arctic”. Shevchenko VP, Van Grieken RE, van Malderen H, Lisitzin AP, Kuptsov VM, Serova VV, Doklady earth sciences 366, 546 (1999)
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Practical tool for sampling and fast analysis of large cocaine seizures”. Eliaerts J, Meert N, Van Durme F, Samyn N, De Wael K, Dardenne P, Drug testing and analysis 10, 1039 (2018). http://doi.org/10.1002/DTA.2364
Abstract: Large quantities of illicit drugs are frequently seized by law enforcement. In such cases, a representative number of samples needs to be quickly examined prior to destruction. No procedure has yet been set up which rapidly provides information regarding the homogeneity of the samples, the presence of controlled substances and the degree of purity. This study establishes a protocol for fast analysis of cocaine and its most common cutting agent, levamisole, in large seizures. The protocol is based on a hypergeometric sampling approach combined with FTIR spectrometry and Support Vector Machines (SVM) algorithms as analysis methods. To demonstrate the practical use of this approach, five large cocaine seizures (consisting between 45 and 85 units) were analysed simultaneously with GC-MS, GC-FID and a portable FTIR spectrometer using Attenuated Total Reflectance (ATR) sampling combined with SVM models. According to the hypergeometric sampling plan of the Drugs Working Group ENFSI guidelines, the required number of subsamples ranged between 19 and 23. Considering the identification analyses, the SVM models detected cocaine and levamisole in all subsamples of cases 1 to 5 (100% correct classification), which was confirmed by GC-MS analysis. Considering the quantification analyses, the SVM models were able to estimate the cocaine and levamisole content in each subsample, compared to GC-FID data. The developed strategy is easy, cost effective and provides immediate information about both the presence and concentration of cocaine and levamisole. By using this new strategy, the number of confirmation analyses with laborious and expensive chromatographic techniques could be significantly reduced.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.469
Times cited: 1
DOI: 10.1002/DTA.2364
|
|
|
“Rapid classification and quantification of cocaine in seized powders with ATR-FTIR and chemometrics”. Eliaerts J, Dardenne P, Meert N, Van Durme F, Samyn N, Janssens K, De Wael K, Drug testing and analysis 9, 1480 (2017). http://doi.org/10.1002/DTA.2149
Abstract: Traditionally, fast screening for the presence of cocaine in unknown powders is performed by means of colour tests. The major drawbacks of these tests are subjective colour evaluation depending on the operator (50 shades of blue) and a lack of selectivity. An alternative fast screening technique is Fourier Transform InfraRed (FTIR) spectrometry. This technique provides spectra that are difficult to interpret without specialized expertise and showing a lack of sensitivity for the detection of cocaine in mixtures. To overcome these limitations, a portable FTIR spectrometer using Attenuated Total Reflectance (ATR) sampling was combined with a multivariate technique, called Support Vector Machines (SVM). Representative street drug powders (n = 482), seized during the period January 2013 to July 2015, and reference powders (n = 33) were used to build and validate a classification model (n = 515) and a quantification model (n = 378). Both models were compared with the conventional chromatographic techniques. The SVM classification model showed a high sensitivity, specificity and efficiency (99%). The SVM quantification model determined cocaine content with a root mean squared error of prediction (RMSEP) of 6% calculated over a wide working range from 4 to 99 w%. In conclusion, the developed models resulted in a clear output (cocaine detected or cocaine not detected) and a reliable estimation of the cocaine content in a wide variety of mixtures. The ATR-FTIR technique combined with SVM is a straightforward, user-friendly and fast approach for routine classification and quantification of cocaine in seized powders.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.469
Times cited: 9
DOI: 10.1002/DTA.2149
|
|
|
“Electrochemical profiling and liquid chromatography–mass spectrometry characterization of synthetic cathinones : from methodology to detection in forensic samples”. Schram J, Parrilla M, Sleegers N, Van Durme F, van den Berg J, van Nuijs ALN, De Wael K, Drug Testing And Analysis 13, 1282 (2021). http://doi.org/10.1002/DTA.3018
Abstract: The emergence of new psychoactive drugs in the market demands rapid and accurate tools for the on‐site classification of illegal and legal compounds with similar structures. Herein, a novel method for the classification of synthetic cathinones (SC) is presented based on their electrochemical profile. First, the electrochemical profile of five common SC (i.e., mephedrone, ethcathinone, methylone, butylone and 4‐chloro‐alpha‐pyrrolidinovalerophenone) is collected to build calibration curves using square wave voltammetry on graphite screen‐printed electrodes (SPE). Second, the elucidation of the oxidation pathways, obtained by liquid chromatography‐high resolution mass spectrometry, allows the pairing of the oxidation products to the SC electrochemical profile, providing a selective and robust classification. Additionally, the effect of common adulterants and illicit drugs on the electrochemical profile of the SC is explored. Interestingly, a cathodic pretreatment of the SPE allows the selective detection of each SC in presence of electroactive adulterants. Finally, the electrochemical approach is validated with gas‐chromatography‐mass spectrometry by analyzing 26 confiscated samples from seizures and illegal webshops. Overall, the electrochemical method exhibits a successful classification of SC including structural derivatives, a crucial attribute in an ever‐diversifying drug market.
Keywords: A1 Journal article; Pharmacology. Therapy; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre
Impact Factor: 3.469
DOI: 10.1002/DTA.3018
|
|
|
“Identification by Raman spectroscopy of pararealgar as a starting material in the synthesis of amorphous arsenic sulfide pigments”. Vermeulen M, Saverwyns S, Coudray A, Janssens K, Sanyova J, Dyes and pigments 149, 290 (2018). http://doi.org/10.1016/J.DYEPIG.2017.10.009
Abstract: In this study, a combination of elemental analytical techniques (MA-XRF and SEM-EDX) were used to localize arsenic sulfide pigments within a 17th-century Dutch painting and in the stratigraphy of an 18th-century Flemish polychrome sculpture. Once located, Raman spectroscopy was used to obtain the vibrational signature of the arsenic sulfide pigments employed. By means of the latter analytical technique and due to the very distinctive Raman scattering signal of the various arsenic sulfide compounds, it was possible to identify the arsenic-based pigments as natural orpiment and amorphous arsenic sulfide. In the latter case, based on the minor bands observed and the good condition of the paint layers, it was possible to identify pararealgar, the orangey-yellow to yellow degradation product of realgar, as the initial arsenic sulfide material used for the synthesis of the amorphous pigment. To the best of our knowledge, this is the first time that combined pararealgar/amorphous arsenic sulfide Raman spectra are reported in historical samples. Therefore, this would be the first identification of pararealgar as the starting material to produce amorphous, arsenic sulfide pigments used in artworks.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.473
Times cited: 7
DOI: 10.1016/J.DYEPIG.2017.10.009
|
|
|
“Photodegradation mechanisms and kinetics of Eosin-Y in oxic and anoxic conditions”. Alvarez-Martin A, Trashin S, Cuykx M, Covaci A, De Wael K, Janssens K, Dyes and pigments 145, 376 (2017). http://doi.org/10.1016/J.DYEPIG.2017.06.031
Abstract: Lakes based on Eosin-Y are extensively used by 19th century artists. Unfortunately, the identification of these pigments in paintings is a difficult task because Eosin-Y degrades very fast under the influence of light. The characterization of the (photo)degradation products of Eosin-Y can be very useful for the identification of these pigments in historic works of art and related cultural heritage artifacts. Furthermore, knowledge on how different factors influence the discoloration process (e.g. different types of irradiation sources and presence/absence of oxygen) is a valuable tool for preventive conservation. To this aim we performed a study on the photodegradation of Eosin-Y in solution under different illumination and in both oxic and anoxic conditions. The photodegradation of Eosin-Y was monitored by UV-VIS spectrophotometry, LC-QTOFMS and electrochemistry techniques. Results indicated higher degradation rates, by a factor of 20 or higher, under illumination with wavelengths near to the main absorbance band of the red pigment. Two different degradation pathways are observed under the conditions studied. LC-QTOFMS and electrochemistry suggested that in the presence of oxygen the degradation mechanism is an oxidative process where the breakdown of the structure causes the total discoloration. Meanwhile under anoxic conditions, a debromination process takes place while the chromophore, and consequently the color of the molecule in solution, remains essentially intact.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre
Impact Factor: 3.473
Times cited: 18
DOI: 10.1016/J.DYEPIG.2017.06.031
|
|
|
“Understanding the (in)stability of semiconductor pigments by a thermodynamic approach”. Anaf W, Schalm O, Janssens K, De Wael K, Dyes and pigments 113, 409 (2015). http://doi.org/10.1016/J.DYEPIG.2014.09.015
Abstract: Several artists pigments are semiconductors. Some of these materials appear stable over time, whereas others already show remarkable signs of degradation after limited time periods. The (in)stability of these pigments can be understood using a thermodynamic approach. For several pigment-related materials, the thermodynamic oxidation and reduction potential (ϕox and ϕred) were determined and evaluated considering the absolute energy positions of the valence and conduction band edges and the water redox potentials. The positions of ϕox and ϕred can be used in a fast screening of the stability of semiconductor pigments towards photoinduced corrosion in an aqueous/humid environment. This theoretical approach corresponds well with experimental data on pigment permanence and degradation phenomena found in literature.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
Impact Factor: 3.473
Times cited: 14
DOI: 10.1016/J.DYEPIG.2014.09.015
|
|
|
“Geranium lake pigments : the role of the synthesis on the structure and composition”. Beltran V, Marchetti A, De Meyer S, Nuyts G, De Wael K, Dyes And Pigments 189, 109260 (2021). http://doi.org/10.1016/J.DYEPIG.2021.109260
Abstract: Eosin Y has an extraordinary capacity to form complexes with metallic elements, that have applications in many different fields, from photovoltaics and photocatalysis to historical artists? pigments. To unravel the complexes reactivity, it is essential to have a precise knowledge of their structure and composition, as well as how these can be affected by the synthesis protocol, an often underestimated factor. This manuscript presents a thorough investigation of the structure and composition of eosin Y complexes based on Al and Pb, by FTIR, XRPD and Raman spectroscopy, with a particular focus on the effect of the synthesis conditions. Results clearly show the change of the coordination mode in Pb complexes depending on the protocol, while the structure of Al complexes remains stable. In both cases, the formation of by-products was observed. Additionally, a detailed band assignment of the FTIR and Raman spectra of eosin Y and Pb and Al complexes is described, providing interesting details such as the interaction between the metallic ion and the xanthene moiety (chromophore). This is extremely important for the analysis of historical paintings where eosin Y is bonded to metallic ions, as well as for other materials in dye-sensitized solar cells, wastewater treatment or photocatalysis.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.473
DOI: 10.1016/J.DYEPIG.2021.109260
|
|
|
“Characterisation of individual atmospheric particles within the Royal Museum of the Wawel Castle in Cracow, Poland”. Worobiec A, Stefaniak EA, Kontozova V, Samek L, Karaszkiewicz P, van Meel K, Van Grieken R, e-Preservation Science 3, 63 (2006)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“Composition of pigments on human bones found in excavations in Argentina studied with micro-Raman spectrometry and scanning electron microscopy”. Darchuk L, Stefaniak EA, Vázquez C, Palacios OM, Worobiec A, Van Grieken R, e-Preservation Science 6, 112 (2009)
Abstract: Results on analysis of prehistoric pigments from excavations and pigments on coloured child bones from North Patagonia, Argentina, are reported. To analyze their composition we used two micro-analytical techniques: micro- Raman spectrometry (MRS) and scanning electron microscopy coupled with X-ray micro-analysis (SEM/EDX). Most investigated excavated pigments show red or yellow ochres consistent with reddish or yellow minerals, such as á- and ã-goethite, haematite, erdite, haapalaite and jarosite. Raman spectra show also evidence of calcium oxalate monohydrate and calcite indicating lichen activity. Pigments covering human bones were identified as hematite and magnetite. This study allows us to infer that pigments found in excavation were employed for burial ceremonies, even though distances between excavated pigment archaeological site and buried remains are quite far, more than 50 km in a straight line.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“Carbonates from the lower part of transition zone or even the lower mantle”. Brenker FE, Vollmer C, Vincze L, Vekemans B, Szymanski A, Janssens K, Szaloki I, Nasdala L, Joswig W, Kaminsky F, Earth and planetary science letters 260, 1 (2007). http://doi.org/10.1016/J.EPSL.2007.02.038
Abstract: Effective CO2-storage in the shallow solid Earth mainly occurs by the formation of carbonates. Although the possibility of transport and storage of carbonates to great depth is demonstrated experimentally, ultra-deep mantle carbonates have not been found before. Applying several in situ analytical techniques on inclusions in diamonds from Juina (Brazil) originating from the lower part of the transition zone (> 580 km) or even the lower mantle (> 670 km), reveal the existence of deep Earth carbonates. These finding unquestionably show that at least locally carbonates exist within the deep Earth and may indicate that the Earth's global CO2-cycle has an ultra-deep extension.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.409
Times cited: 156
DOI: 10.1016/J.EPSL.2007.02.038
|
|
|
“Detection of a Ca-rich lithology in the Earth's deep (>, 300 km) convecting mantle”. Brenker FE, Vincze L, Vekemans B, Nasdala L, Stachel T, Vollmer C, Kersten M, Somogyi A, Adams F, Joswig W, Harris JW, Earth and planetary science letters 236, 579 (2005). http://doi.org/10.1016/J.EPSL.2005.05.021
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.EPSL.2005.05.021
|
|
|
“Patterns of damage in igneous and sedimentary rocks under conditions simulating sea-salt weathering”. Cardell C, Rivas T, Mosquera MJ, Birginie JM, Moropoulou A, Prieto B, Silva B, Van Grieken R, Earth surface processes and landforms 28, 1 (2003). http://doi.org/10.1002/ESP.408
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/ESP.408
|
|
|
“Modelling concentrations of airborne primary and secondary PM10 and PM2.5 with the BelEUROS-model in Belgium”. Deutsch F, Vankerkom J, Janssen L, Janssen S, Bencs L, Van Grieken R, Fierens F, Dumont G, Mensink C, Ecological modelling 217, 230 (2008). http://doi.org/10.1016/J.ECOLMODEL.2008.06.003
Abstract: The Eulerian Chemistry-Transport Model BelEUROS was used to calculate the concentrations of airborne PM10 and PM2.5 over Europe. Both primary as well as secondary particulate matter in the respirable size-range was taken into account. Especially PM2.5 aerosols are often formed in the atmosphere from gaseous precursor compounds. Comprehensive computer codes for the calculation of gas phase chemical reactions and thermodynamic equilibria between compounds in the gas-phase and the particulate phase had been implemented into the BelEUROS-model. Calculated concentrations of PM10 and PM2.5 are compared to observations, including both the spatial and daily, temporal distribution of particulate matter in Belgium for certain monitoring locations and periods. The concentrations of the secondary compounds ammonium, nitrate and sulfate have also been compared to observed values. BeIEUROS was found to reproduce the observed concentrations rather well. The model was applied to assess the contribution of emissions derived from the sector agriculture in Flanders, the northern part of Belgium, to PM10- and PM2.5-concentrations. The results demonstrate the importance of ammonia emissions in the formation of secondary particulate matter. Hence, future European emission abatement policy should consider more the role of ammonia in the formation of secondary particles
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.ECOLMODEL.2008.06.003
|
|
|
“Electropolymerized o-phenylenediamine on graphite promoting the electrochemical detection of nafcillin”. Bottari F, Moro G, Sleegers N, Florea A, Cowen T, Piletsky S, van Nuijs ALN, De Wael K, Electroanalysis 32, 135 (2019). http://doi.org/10.1002/ELAN.201900397
Abstract: By combining molecular modelling and electrochemistry we envision the creation of modified electrodes tailored for a more sensitive and selective detection of a single analyte. In this study we report on a graphite screen printed electrode modified with electropolymerized o-phenylenediamine, selected by rational design, which promotes the detection of nafcillin (NAF), an antibiotic. Parameters such as monomer concentration, pH and number of electropolymerization cycles were optimized to obtain the highest current signal for the target upon amperometric detection. NAF identification was based on the redox process at +1.1 V (vs pseudo Ag), ascribed to the oxidation of the C-7 side chain. With the optimized modification protocol, a two-fold increase in nafcillin signal could be obtained: the calibration plot in 0.1 M Britton-Robinson buffer pH 4 showed a limit of detection of 80 nM with improved sensitivity and reproducibility (RSD<5 %) compared to the detection at non-modified electrodes.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre
Impact Factor: 2.851
Times cited: 1
DOI: 10.1002/ELAN.201900397
|
|
|
“Fullerene-\beta-cyclodextrin conjugate based electrochemical sensing device for ultrasensitive detection of p-nitrophenol”. Rather JA, Debnath P, De Wael K, Electroanalysis 25, 2145 (2013). http://doi.org/10.1002/ELAN.201300304
Abstract: The article describes the use of a fullerene (C60)-β-cyclodextrin conjugate, synthesized via 1,3-dipolar cycloaddition, for the ultrasensitive electrochemical detection of p-nitrophenol. This conjugate was successfully immobilized on the surface of a glassy carbon electrode and the developed device showed high activity towards p-nitrophenol due to the synergetic effect of C60, the latter becoming highly conductive upon reduction. The determination of p-nitrophenol was performed by using square wave voltammetry over a concentration range from 2.8×10−9 mol L−1 to 4.2×10−7 mol L−1 and the detection limit was calculated to be 1.2×10−9 mol L−1.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.851
Times cited: 13
DOI: 10.1002/ELAN.201300304
|
|
|
“Intercalation of proflavine in ssDNA aptamers : effect on binding of the specific target chloramphenicol”. Pilehvar S, Jambrec D, Gebala M, Schuhmann W, De Wael K, Electroanalysis 27, 1836 (2015). http://doi.org/10.1002/ELAN.201500192
Abstract: The structural modification of ssDNA-based aptamers upon specific binding of its target molecule leads to changes of the charge-transfer resistance (Rct) of a negatively-charged free-diffusing redox probe. The aptamer adopts a structure due to self-hybridization which is stabilized using profalvine as intercalator. The pre-organized aptamer structure is used to detect chloramphenicol (CAP) requiring a substantial change of the aptamer structure indicated by a CAP concentration dependent increase in the Rct values. Pre-incubation of the aptamer-modified electrode with an intercalator allows for the modulation of the aptamer/target interaction and hence for a modulation of the CAP-dependent variation of the Rct values.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.851
Times cited: 5
DOI: 10.1002/ELAN.201500192
|
|
|
“Label-free impedance aptasensor for major peanut allergen Ara h 1”. Trashin S, De Jong M, Breugelmans T, Pilehvar S, De Wael K, Electroanalysis 27, 32 (2015). http://doi.org/10.1002/ELAN.201400365
Abstract: The peanut allergen Ara h 1 belonging to the vicilin family of seed storage proteins is known to be a suitable marker for peanut detection in foods. In the present work, we suggest an electrochemical detection of Ara h 1 using a recently selected 80-base DNA aptamer. The detection strategy relies on insulation effect of a bulky protein captured by an immobilized aptamer. The electrodes were modified by the aptamer and characterized using electrochemical impedance spectroscopy (EIS). The aptamer surface density and analytical parameters of the calibration curves for Ara h 1 were compared with the system prepared with thrombin binding aptamer (TBA) and operated in the same conditions.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Applied Electrochemistry & Catalysis (ELCAT)
Times cited: 10
DOI: 10.1002/ELAN.201400365
|
|
|
“Highly sensitive and selective voltammetric sensor fullerene modified glassy carbon electrode for determination of cefitizoxime in solubilized system”. Jain R, Rather JA, Dwivedi A, Vikas, Electroanalysis 22, 2600 (2010). http://doi.org/10.1002/ELAN.201000243
Abstract: The usefulness of fullerene modified glassy carbon electrode in mediating the reduction of cefitizoxime in solubilized system has been demonstrated. Due to the unique structure and extraordinary properties, fullerene shows higher catalytic efficiency towards cefitizoxime reduction. The kinetic parameters, electron transfer coefficient (α) and rate constant (K0) across the modified electrode are 0.37 and 0.1081/s respectively. The proposed square-wave voltammetric method is linear over the concentration range 1.210.3 µg/mL. The limit of detection (LOD) is found 0.27 ng/mL. High sensitivity and selectivity together with low detection limit of the electrode response make it suitable for the determination of cefitizoxime.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/ELAN.201000243
|
|
|
“A new multisine-based impedimetric aptasensing platform”. Pauwels D, Pilehvar S, Geboes B, Hubin A, De Wael K, Breugelmans T, Electrochemistry communications 71, 23 (2016). http://doi.org/10.1016/J.ELECOM.2016.07.010
Abstract: In this work an aptamer-based biosensor is combined with a multisine electrochemical impedance spectroscopy sensing methodology into a novel and promising biosensing strategy. Employing a multisine instead of a traditional single sine measuring method allows the detection and quantification of parameters that provide information about the accuracy and reliability of the results, such as noise and distortions. This does not only lead to a shorter measurement time, but it also enables an easy and fast evaluation of the quality of the data and fitting, leading to more accurate results.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Applied Electrochemistry & Catalysis (ELCAT)
Impact Factor: 4.396
Times cited: 1
DOI: 10.1016/J.ELECOM.2016.07.010
|
|
|
“Integration of a photoelectrochemical cell in a flow system for quantification of 4-aminophenol with titanium dioxide”. Mendonça CD, Rahemi V, Hereijgers J, Breugelmans T, Machado SAS, De Wael K, Electrochemistry Communications 117, 106767 (2020). http://doi.org/10.1016/J.ELECOM.2020.106767
Abstract: The photoelectrochemical quantification of phenolic compounds such as hydroquinone (HQ) and 4-aminophenol (4-AP) is accomplished by integrating a photoelectrochemical cell into a flow injection analysis (FIA) setup. It is a well-known fact that during the electroanalysis of phenolic compounds, the electrode surface is susceptible to poisoning. However, electrode fouling can be reduced significantly by using the FIA system with periodic washing of the electrode. Reactive oxygen species (ROS), which are generated on the surface of TiO2 under UV light, can oxidize phenolic compounds such as 4-AP. The oxidized form of 4-AP is reduced back at the electrode surface, generating a measurable signal proportional to its concentration. The factors influencing the perfor-mance of the sensor, such as flow rate, applied potential for back reduction and pH, are investigated in detail. In the concentration range 0.0125-1.0 mu M, a linear correlation between the photocurrent and the concentration of 4-AP was observed with a sensitivity of 0.6 A M-1 cm(-2) and a limit of detection of 18 nM. A straightforward analytical methodology for the on-site, highly sensitive and low-cost quantification of phenolic compounds is presented, based on the use of TiO2 in a photoelectrochemical flow cell.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Applied Electrochemistry & Catalysis (ELCAT)
Impact Factor: 5.4
Times cited: 1
DOI: 10.1016/J.ELECOM.2020.106767
|
|