|
“Accurate measurements of atomic displacements in La0.9Sr0.1MnO3 thin films grown on a SrTiO3 substrate”. Geuens P, Lebedev OI, van Dyck D, Van Tendeloo G s.l., page 1133 (2000).
Keywords: H3 Book chapter; Electron microscopy for materials research (EMAT); Vision lab
|
|
|
Amelinckx S, van Dyck D, van Landuyt J, Van Tendeloo G (1997) Electron microscopy: principles and fundamentals. Vch, Weinheim
Keywords: ME1 Book as editor or co-editor; Electron microscopy for materials research (EMAT); Vision lab
|
|
|
“Enamels in stained-glass windows : preparation, chemical composition, microstructure and causes of deterioration”. Caen J, Schalm O, van der Snickt G, van der Linden V, Frederickx P, Schryvers D, Janssens K, Cornelis E, van Dyck D, Schreiner M, , 121 (2005)
Keywords: P3 Proceeding; Art; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Vision lab
|
|
|
Amelinckx S, van Dyck D, van Landuyt J, Van Tendeloo G (1997) Handbook of microscopy: applications in materials science, solid-state physics and chemistry. Vch, Weinheim
Keywords: ME1 Book as editor or co-editor; Electron microscopy for materials research (EMAT); Vision lab
|
|
|
“The notion of resolution”. Van Aert S, den Dekker AJ, van Dyck D, van den Bos A Springer, Berlin, page 1228 (2008).
Keywords: H3 Book chapter; Electron microscopy for materials research (EMAT); Vision lab
|
|
|
“The notion of resolution”. Van Aert S, den Dekker AJ, van Dyck D, van den Bos A Springer, Berlin, page 1228 (2007).
Keywords: H3 Book chapter; Electron microscopy for materials research (EMAT); Vision lab
|
|
|
“Statistical experimental design for quantitative atomic resolution transmission electron microscopy”. Van Aert S, den Dekker AJ, van den Bos A, van Dyck D Academic Press, San Diego, Calif., page 1 (2004).
Keywords: H1 Book chapter; Electron microscopy for materials research (EMAT); Vision lab
Times cited: 13
DOI: 10.1016/S1076-5670(04)30001-7
|
|
|
“The benefits of statistical parameter estimation theory for quantitative interpretation of electron microscopy data”. Van Aert S, Bals S, Chang LY, den Dekker AJ, Kirkland AI, Van Dyck D, Van Tendeloo G Springer, Berlin, page 97 (2008).
Keywords: H1 Book chapter; Electron microscopy for materials research (EMAT); Vision lab
DOI: 10.1007/978-3-540-85156-1_49
|
|
|
“Investigation of the chemical state and 3D distribution of Mn in corroded glass fragments”. Proost K, Schalm O, Janssens K, Van Dyck D (2005).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Vision lab
|
|
|
“High resolution electron microscopy from imaging towards measuring”. Van Aert S, den Dekker AJ, van den Bos A, Van Dyck D ... IEEE International Instrumentation and Measurement Technology Conference
T2 – Rediscovering measurement in the age of informatics : proceedings of the 18th IEEE Instrumentation and Measurement Technology Conference (IMTC), 2001: vol 3. Ieee, page 2081 (2001).
Keywords: H2 Book chapter; Electron microscopy for materials research (EMAT); Vision lab
DOI: 10.1109/IMTC.2001.929564
|
|
|
“An accurate parameterization for scattering factors, electron densities and electrostatic potentials for neutral atoms that obey all physical constraints”. Lobato Hoyos IP, van Dyck D, Acta crystallographica: section A: foundations of crystallography 70, 636 (2014). http://doi.org/10.1107/S205327331401643X
Abstract: An efficient procedure and computer program are outlined for fitting numerical X-ray and electron scattering factors with the correct inclusion of all physical constraints. The numerical electron scattering factors have been parameterized using five analytic non-relativistic hydrogen electron scattering factors as basis functions for 103 neutral atoms of the periodic table. The inclusion of the correct physical constraints in the electron scattering factor and its derived quantities allows the use of the new parameterization in different fields. In terms of quality of the fit, the proposed parameterization of the electron scattering factor is one order of magnitude better than the previous analytic fittings.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 5.725
Times cited: 19
DOI: 10.1107/S205327331401643X
|
|
|
“Advanced electron microscopy for advanced materials”. Van Tendeloo G, Bals S, Van Aert S, Verbeeck J, van Dyck D, Advanced materials 24, 5655 (2012). http://doi.org/10.1002/adma.201202107
Abstract: The idea of this Review is to introduce newly developed possibilities of advanced electron microscopy to the materials science community. Over the last decade, electron microscopy has evolved into a full analytical tool, able to provide atomic scale information on the position, nature, and even the valency atoms. This information is classically obtained in two dimensions (2D), but can now also be obtained in 3D. We show examples of applications in the field of nanoparticles and interfaces.
Keywords: A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 19.791
Times cited: 107
DOI: 10.1002/adma.201202107
|
|
|
“Holotomography: quantitative phase tomography with micrometer resolution using hard synchrotron radiation X-rays”. Cloetens P, Ludwig W, Baruchel J, van Dyck D, van Landuyt J, Guigay JP, Schlenker M, Applied physics letters 75, 2912 (1999). http://doi.org/10.1063/1.125225
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 3.411
Times cited: 481
DOI: 10.1063/1.125225
|
|
|
“Statistical method for thickness measurement of amorphous objects”. van Dyck D, Croitoru MD, Applied physics letters 90, 241911 (2007). http://doi.org/10.1063/1.2749184
Abstract: The authors propose a nondestructive method for the determination of the thickness of an amorphous sample. This method is based on the statistics of the phase of the electron exit wave function, which depend on the number of atoms traversed by the incident electron which itself is a function of the thickness of the object. The accuracy of this method has been checked numerically by the multislice method and compared with that based on the mean inner potential. (c) 2007 American Institute of Physics.
Keywords: A1 Journal article; Condensed Matter Theory (CMT); Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 3.411
Times cited: 4
DOI: 10.1063/1.2749184
|
|
|
“Ni cluster formation in low temperature annealed Ni50.6Ti49.4”. Pourbabak S, Wang X, Van Dyck D, Verlinden B, Schryvers D, Functional materials letters 10, 1740005 (2017). http://doi.org/10.1142/S1793604717400057
Abstract: Various low temperature treatments of Ni50.6Ti49.4 have shown an unexpected effect on the martensitic start temperature. Periodic diffuse intensity distributions in reciprocal space indicate the formation of short pure Ni strings along the <111> directions in the B2 ordered lattice, precursing the formation of Ni4Ti3 precipitates formed at higher annealing temperatures.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 1.234
Times cited: 4
DOI: 10.1142/S1793604717400057
|
|
|
“Electron diffraction evidence for ordering of interstitial silver ions in silver bromide microcrystals”. Goessens C, Schryvers D, van Dyck D, van Landuyt J, de Keyzer R, Icem 13 (1994)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
|
|
|
“High-resolution electron microscopy : from imaging toward measuring”. Van Aert S, den Dekker AJ, van den Bos A, van Dyck D, IEEE transactions on instrumentation and measurement 51, 611 (2002). http://doi.org/10.1109/TIM.2002.802250
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.456
Times cited: 13
DOI: 10.1109/TIM.2002.802250
|
|
|
“Present state of the composition evaluation of ternary semiconductor nanostructures by lattice fringe analysis”. Rosenauer A, Gerthsen D, Van Aert S, van Dyck D, den Dekker AJ, Institute of physics conference series , 19 (2003)
Abstract: Semiconductor heterostructures are used for the fabrication of optoelectronic devices. Performance of such devices is governed by their chemical morphology. The composition distribution of quantum wells and dots is influenced by kinetic growth processes which are not understood completely at present. To obtain more information about these effects, methods for composition determination with a spatial resolution at a near atomic scale are necessary. In this paper we focus on the present state of the composition evaluation by the lattice fringe analysis (CELFA) technique and explain the basic ideas, optimum imaging conditions, precision and accuracy.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
|
|
|
“Towards quantitative high resolution electron microscopy?”.Van Tendeloo G, op de Beeck M, De Meulenaere P, van Dyck D, Institute of physics conference series 147, 67 (1995)
Abstract: The basics of the interpretation of high resolution images showing detail of the order of 0.1 nm are shortly explained here. The use of a field emission source, a CCD camera and an adapted reconstruction method for restoring the projected crystal potential (focus variation method) allows a quantitative interpretation of HREM images. Examples of partially disordered alloys and carbonate ordering in high Tc superconductors are presented.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
|
|
|
“Atomic resolution electron tomography: a dream?”.van Dyck D, Van Aert S, Croitoru M, International journal of materials research 97, 872 (2006). http://doi.org/10.3139/146.101314
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Condensed Matter Theory (CMT); Vision lab
Impact Factor: 0.681
Times cited: 6
DOI: 10.3139/146.101314
|
|
|
“Advanced electron crystallography through model-based imaging”. Van Aert S, De Backer A, Martinez GT, den Dekker AJ, Van Dyck D, Bals S, Van Tendeloo G, IUCrJ 3, 71 (2016). http://doi.org/10.1107/S2052252515019727
Abstract: The increasing need for precise determination of the atomic arrangement of non-periodic structures in materials design and the control of nanostructures explains the growing interest in quantitative transmission electron microscopy. The aim is to extract precise and accurate numbers for unknown structure parameters including atomic positions, chemical concentrations and atomic numbers. For this purpose, statistical parameter estimation theory has been shown to provide reliable results. In this theory, observations are considered purely as data planes, from which structure parameters have to be determined using a parametric model describing the images. As such, the positions of atom columns can be measured with a precision of the order of a few picometres, even though the resolution of the electron microscope is still one or two orders of magnitude larger. Moreover, small differences in average atomic number, which cannot be distinguished visually, can be quantified using high-angle annular dark-field scanning transmission electron microscopy images. In addition, this theory allows one to measure compositional changes at interfaces, to count atoms with single-atom sensitivity, and to reconstruct atomic structures in three dimensions. This feature article brings the reader up to date, summarizing the underlying theory and highlighting some of the recent applications of quantitative model-based transmisson electron microscopy.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab; Engineering Management (ENM)
Impact Factor: 5.793
Times cited: 30
DOI: 10.1107/S2052252515019727
|
|
|
“High-resolution electron microscopy and electron tomography: resolution versus precision”. Van Aert S, den Dekker AJ, van Dyck D, van den Bos A, Journal of structural biology 138, 21 (2002). http://doi.org/10.1016/S1047-8477(02)00016-3
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.767
Times cited: 33
DOI: 10.1016/S1047-8477(02)00016-3
|
|
|
“An electron microscopic study of highly oriented undoped and FeCl3-doped poly (p-phenylenevinylene)”. Zhang XB, Van Tendeloo G, van Landuyt J, van Dyck D, Briers J, Bao Y, Geise HJ, Macromolecules 29, 1554 (1996). http://doi.org/10.1021/ma9513067
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 5.8
Times cited: 10
DOI: 10.1021/ma9513067
|
|
|
“Do you believe that atoms stay in place when you observe them in HREM?”.van Dyck D, Lobato I, Chen F-R, Kisielowski C, Micron 68, 158 (2015). http://doi.org/10.1016/j.micron.2014.09.003
Abstract: Recent advancements in aberration-corrected electron microscopy allow for an evaluation of unexpectedly large atom displacements beyond a resolution limit of similar to 0.5 angstrom, which are found to be dose-rate dependent in high resolution images. In this paper we outline a consistent description of the electron scattering process, which explains these unexpected phenomena. Our approach links thermal diffuse scattering to electron beam-induced object excitation and relaxation processes, which strongly contribute to the image formation process. The effect can provide an explanation for the well-known contrast mismatch (“Stobbs factor”) between image calculations and experiments. (C) 2014 Elsevier Ltd. All rights reserved.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 1.98
Times cited: 11
DOI: 10.1016/j.micron.2014.09.003
|
|
|
“How to optimize the experimental design of quantitative atomic resolution TEM experiments?”.Van Aert S, den Dekker AJ, van Dyck D, Micron 35, 425 (2004). http://doi.org/10.1016/j.micron.2004.01.007
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 1.98
Times cited: 14
DOI: 10.1016/j.micron.2004.01.007
|
|
|
“Imaging from atomic structure to electronic structure”. Xu Q, Zandbergen HW, van Dyck D, Micron 43, 524 (2012). http://doi.org/10.1016/j.micron.2011.10.024
Abstract: This paper discusses the possibility of retrieving the electron distribution (with highlighted valence electron distribution information) of materials from recorded HREM images. This process can be achieved by solving two inverse problems: reconstruction of the exit wave and reconstruction of the electron distribution from exit waves. The first inverse problem can be solved using a focal series reconstruction method. We show that the second inverse problem can be solved by combining a series of exit waves recorded at different thickness conditions. This process is designed based on an improved understanding of the dynamical scattering process. It also explains the fundamental difficulty of obtaining the valence electron distribution information and the basis of our solution.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 1.98
DOI: 10.1016/j.micron.2011.10.024
|
|
|
“Model-based electron microscopy : from images toward precise numbers for unknown structure parameters”. Van Aert S, van den Broek W, Goos P, van Dyck D, Micron 43, 509 (2012). http://doi.org/10.1016/j.micron.2011.10.019
Abstract: Statistical parameter estimation theory is proposed as a method to quantify electron microscopy images. It aims at obtaining precise and accurate values for the unknown structure parameters including, for example, atomic column positions and types. In this theory, observations are purely considered as data planes, from which structure parameters have to be determined using a parametric model describing the images. The method enables us to measure positions of atomic columns with a precision of the order of a few picometers even though the resolution of the electron microscope is one or two orders of magnitude larger. Moreover, small differences in averaged atomic number, which cannot be distinguished visually, can be quantified using high-angle annular dark field scanning transmission electron microscopy images. Finally, it is shown how to optimize the experimental design so as to attain the highest precision. As an example, the optimization of the probe size for nanoparticle radius measurements is considered. It is also shown how to quantitatively balance signal-to-noise ratio and resolution by adjusting the probe size.
Keywords: A1 Journal article; Engineering Management (ENM); Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 1.98
Times cited: 7
DOI: 10.1016/j.micron.2011.10.019
|
|
|
“Atomic resolution mapping using quantitative high-angle annular dark field scanning transmission electron microscopy”. Van Aert S, Verbeeck J, Bals S, Erni R, van Dyck D, Van Tendeloo G, Microscopy and microanalysis 15, 464 (2009). http://doi.org/10.1017/S1431927609093957
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 1.891
Times cited: 1
DOI: 10.1017/S1431927609093957
|
|
|
“Fully automated measurement of the modulation transfer function of charge-coupled devices above the Nyquist frequency”. van den Broek W, Van Aert S, van Dyck D, Microscopy and microanalysis 18, 336 (2012). http://doi.org/10.1017/S1431927611012633
Abstract: The charge-coupled devices used in electron microscopy are coated with a scintillating crystal that gives rise to a severe modulation transfer function (MTF). Exact knowledge of the MTF is imperative for a good correspondence between image simulation and experiment. We present a practical method to measure the MTF above the Nyquist frequency from the beam blocker's shadow image. The image processing has been fully automated and the program is made public. The method is successfully tested on three cameras with various beam blocker shapes.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 1.891
Times cited: 15
DOI: 10.1017/S1431927611012633
|
|
|
“Physical limits on atomic resolution”. van Dyck D, Van Aert S, den Dekker AJ, Microscopy and microanalysis 10, 153 (2004). http://doi.org/10.1017/S143192760404036X
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 1.891
Times cited: 14
DOI: 10.1017/S143192760404036X
|
|