Details
   web
Records
Author Van Grieken, R.; Van de Velde, R.; Robberecht, H.
Title Sample contamination from a commercial grinding unit Type A1 Journal article
Year 1980 Publication Analytica chimica acta Abbreviated Journal
Volume 118 Issue 1 Pages 137-143
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract The contamination of ground samples by a commercially available Lovibond McCrone Micronizing Mill is discussed. Tracer and weighing experiments showed that abrasion of corundum grinding elements was important, introducing 620 mg of abrasion products per minute of wet grinding. Agate grinding elements were abraded at ⩽6 mg min-1. The abrasion products and grinding elements were analyzed by x-ray fluorescence, spark-source mass spectrometry and neutron activation analysis. Contamination in trace element analysis of geological materials is likely to be negligible for agate grinding elements and, except for a few transition metals, also for corundum grinding elements. Contamination of typical biological samples is significant for a few elements even when agate elements are used, and is absolutely prohibitive for trace analysis when corundum elements are used.
Address
Corporate Author Thesis
Publisher Place of Publication (up) Editor
Language Wos A1980JZ95100016 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; 1873-4324 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116436 Serial 8492
Permanent link to this record
 

 
Author Vandecasteele, C.; Van Grieken, R.; Hoste, J.
Title Simultaneous determination of chromium and silicon in steel by 14-mev neutron activation analysis Type A1 Journal article
Year 1974 Publication Analytica chimica acta Abbreviated Journal
Volume 72 Issue 1 Pages 31-36
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Chromium and silicon are determined simultaneously in steel by 14-MeV neutron activation analysis. The activities of 52V(Eγ=1.43 MeV,TView the MathML source=3.76 min) from 52Cr(n,p)52V and 28Al (Eγ=1.78 MeV; TView the MathML source=2.24 min) from 28Si(n,p)28Al are evaluated by mixed γ-ray spectrometry. The influence of manganese and phosphorus, the main interfering elements, is negligible for most stainless steels. The count rate should be limited, to avoid 52V pulse pile-up effects interfering in the 28Al energy region. Precisions in the 2-10% range are reached, depending on the concentrations, for a 10-min analysis time. Results for a series of steel samples are compared with industrial analyses.
Address
Corporate Author Thesis
Publisher Place of Publication (up) Editor
Language Wos A1974U036600002 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; 1873-4324 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116366 Serial 8527
Permanent link to this record
 

 
Author Van Grieken, R.; Van 't dack, L.; Costa Dantas, C.; Da Silveira Dantas, H.
Title Soil analysis by thin-film energy-dispersive X-ray fluorescence Type A1 Journal article
Year 1979 Publication Analytica chimica acta Abbreviated Journal
Volume 108 Issue Pages 93-101
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Energy-dispersive x-ray fluorescence is advantageous for trace analysis of soils present as thin films. A target thickness of about 2 mg cm-2 provides a compromise between optimal sensitivity and minimal absorption effect or optimal accuracy. Sample preparation involves only suspending the finely ground soil in water and drying this suspension on a thin mylar foil glued on a ring that fits into the x.r.f. spectrometer. The effective sample weight present in the exciting beam area is computed from the scatter peaks, a method that cancels out target heterogeneity problems. High accuracy is demonstrated for many elements in reference soil and rock materials; a precision around 5% and a detection limit around 10 ppm can be achieved. As an illustration, results for 16 trace elements and preliminary interpretation are given for a series of pedologically important soil samples from Brasil.
Address
Corporate Author Thesis
Publisher Place of Publication (up) Editor
Language Wos A1979HL44100012 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; 1873-4324 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:111402 Serial 8549
Permanent link to this record
 

 
Author Otten, P.; Bruynseels, F.; Van Grieken, R.
Title Study of inorganic ammonium compounds in individual marine aerosol particles by laser microprobe mass spectrometry Type A1 Journal article
Year 1987 Publication Analytica chimica acta Abbreviated Journal
Volume 195 Issue Pages 117-124
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Ammonia is important in the atmosphere because it neutralizes acidic species. The relative importance of different inorganic ammonium compounds (chloride, nitrate and sulfate) in marine air chemistry was studied by single-particle characterization with the laser microprobe mass analyser. Standard aerosols were generated as a reference for compound identification, based on the fingerprint spectra obtained, and calculation of the relative sensitivity achieved for different ions in a marine aerosol matrix. The relative sensitivity for ammonium was low. Aerosol samples were collected in the Southern Bight of the North Sea under different meteorological conditions and examined for their ammonium compounds. Samples collected during an inversion period with continental influences showed a much higher content in all particles than samples collected under different meteorological conditions, where ammonium was mostly detected in the submicrometer particle-size range.
Address
Corporate Author Thesis
Publisher Place of Publication (up) Editor
Language Wos A1987K019500010 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; 1873-4324 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116447 Serial 8601
Permanent link to this record
 

 
Author Leysen, L.; Roekens, E.; Komy, Z.; Van Grieken, R.
Title A study of the weathering of an historic building Type A1 Journal article
Year 1987 Publication Analytica chimica acta Abbreviated Journal
Volume 195 Issue Pages 247-255
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Various bulk and surface analytical techniques were used to study the chemical deterioration of the 13th-to-15th century limestone cathedral in Mechelen, Belgium. The weathering crust on the walls was found to be rich in sulfate, regardless of the geographic orientation. Nitrate and chloride were only detected in minor amounts in the crust and run-off samples. Attack by gaseous sulfur compounds seems to play a dominant role in the stone deterioration mechanism. Electron microprobe analysis showed predominantly bar-shaped gypsum crystals in the crust, and laser microprobe mass spectrometry showed that carbon seems to be responsible for the blackness of most crust samples. Automated electron microprobe analysis also indicated significant differences in the analytical composition of suspensions in run-off water and in rain-water.
Address
Corporate Author Thesis
Publisher Place of Publication (up) Editor
Language Wos A1987K019500022 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; 1873-4324 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116446 Serial 8608
Permanent link to this record
 

 
Author Treiger, B.; van Malderen, H.; Bondarenko, I.; van Espen, P.; Van Grieken, R.
Title Studying aerosol samples by non-linear mapping of electron probe microanalysis data Type A1 Journal article
Year 1993 Publication Analytica chimica acta Abbreviated Journal
Volume 284 Issue Pages 119-124
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication (up) Editor
Language Wos A1993MR27600014 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; 1873-4324 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:6224 Serial 8610
Permanent link to this record
 

 
Author Neven, L.; Barich, H.; Sleegers, N.; Cánovas, R.; Debruyne, G.; De Wael, K.
Title Development of a combi-electrosensor for the detection of phenol by combining photoelectrochemistry and square wave voltammetry Type A1 Journal article
Year 2022 Publication Analytica chimica acta Abbreviated Journal
Volume 1206 Issue Pages 339732
Keywords A1 Journal article; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Abstract The high toxicity, endocrine-disrupting effects and low (bio)degradability commonly attributed to phenolic compounds have promoted their recognition as priority toxic pollutants. For this reason, the monitoring of these compounds in industrial, domestic and agricultural streams is crucial to prevent and decrease their toxicity in our daily life. To confront this relevant environmental issue, we propose the use of a combi-electrosensor which combines singlet oxygen (1O2)-based photoelectrochemistry (PEC) with square wave voltammetry (SWV). The high sensitivity of the PEC sensor (being a faster alternative for traditional COD measurements) ensures the detection of nmol L−1 levels of phenolic compounds while the SWV measurements (being faster than the color test kits) allow the differentiation between phenolic compounds. Herein, we report on the development of such a combi-electrosensor for the sensitive and selective detection of phenol (PHOH) in the presence of related phenolic compounds such as hydroquinone (HQ), bisphenol A (BPA), resorcinol (RC) and catechol (CC). The PEC sensor was able to determine the concentration of PHOH in spiked river samples containing only PHOH with a recovery between 96% and 111%. The SWV measurements elucidated the presence of PHOH, HQ and CC in the spiked samples containing multiple phenol compounds. Finally, the practicality of the combi-electrosensor set-up with a dual SPE containing two working electrodes and shared reference and counter electrodes was demonstrated. As a result, the combination of the two techniques is a powerful and valuable tool in the analysis of phenolic samples, since each technique improves the general performance by overcoming the inherent drawbacks that they display independently.
Address
Corporate Author Thesis
Publisher Place of Publication (up) Editor
Language Wos 000793070200016 Publication Date 2022-03-16
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; 1873-4324 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access OpenAccess
Notes Approved no
Call Number UA @ admin @ c:irua:187499 Serial 8848
Permanent link to this record
 

 
Author Moro, G.; Foumthuim, C.J.D.; Spinaci, M.; Martini, E.; Cimino, D.; Balliana, E.; Lieberzeit, P.; Romano, F.; Giacometti, A.; Campos, R.; De Wael, K.; Moretto, L.M.
Title How perfluoroalkyl substances modify fluorinated self-assembled monolayer architectures : an electrochemical and computational study Type A1 Journal article
Year 2022 Publication Analytica chimica acta Abbreviated Journal
Volume 1204 Issue Pages 339740-12
Keywords A1 Journal article; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Abstract There is an urgent need for sensing strategies to screen perfluoroalkyl substances (PFAS) in aqueous matrices. These strategies must be applicable in large-scale monitoring plans to face the ubiquitous use of PFAS, their wide global spread, and their fast evolution towards short-chain, branched molecules. To this aim, the changes in fluorinated self-assembled monolayers (SAM) with different architectures (pinholes/defects-free and with randomized pinholes/defects) were studied upon exposure to both long and short-chain PFAS. The applicability of fluorinated SAM in PFAS sensing was evaluated. Changes in the SAM structures were characterised combining electrochemical impedance spectroscopy and voltam-metric techniques. The experimental data interpretation was supported by molecular dynamics simu-lations to gain a more in-depth understanding of the interaction mechanisms involved. Pinhole/defect-free fluorinated SAM were found to be applicable to long-chain PFAS screening within switch-on sensing strategy, while a switch-off sensing strategy was reported for screening of both short/long-chain PFAS. These strategies confirmed the possibility to play on fluorophilic interactions when designing PFAS screening methods.(c) 2022 Elsevier B.V. All rights reserved.
Address
Corporate Author Thesis
Publisher Place of Publication (up) Editor
Language Wos 000789493000010 Publication Date 2022-03-17
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; 1873-4324 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access Not_Open_Access
Notes Approved no
Call Number UA @ admin @ c:irua:188658 Serial 8880
Permanent link to this record
 

 
Author Adams, F.; Adriaens, A.; Bogaerts, A.
Title Can plasma spectrochemistry assist in improving the accuracy of chemical analysis? Type A1 Journal article
Year 2002 Publication Analytica chimica acta Abbreviated Journal Anal Chim Acta
Volume 456 Issue Pages 63-75
Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication (up) Amsterdam Editor
Language Wos 000174676000007 Publication Date 2002-10-14
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 4.95 Times cited 6 Open Access
Notes Approved Most recent IF: 4.95; 2002 IF: 2.114
Call Number UA @ lucian @ c:irua:38375 Serial 272
Permanent link to this record
 

 
Author Cidu, R.; Fanfani, L.; Shaud, P.; Edmunds, W.M.; Van 't dack, L.; Gijbels, R.
Title Determination of gold at the ultratrace level in natural waters Type A1 Journal article
Year 1994 Publication Analytica chimica acta Abbreviated Journal Anal Chim Acta
Volume 296 Issue Pages 295-304
Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication (up) Amsterdam Editor
Language Wos A1994PM14000010 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 4.513 Times cited 20 Open Access
Notes Approved no
Call Number UA @ lucian @ c:irua:10252 Serial 668
Permanent link to this record
 

 
Author Shazali, I.; Van 't dack, L.; Gijbels, R.
Title Determination of precious metals in ores and rocks by thermal neutron activation/\gamma-spectrometry after preconcentration by nickel sulphide fire assay and coprecipitation with tellurium Type A1 Journal article
Year 1987 Publication Analytica chimica acta Abbreviated Journal Anal Chim Acta
Volume 196 Issue Pages 49-58
Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Abstract The six platinum group elements (Ru, Rh, Pd, Os, Ir and Pt) can be determined in geological samples down to the μg kg−1 level, by using nickel sulphide fire assay and neutron activation of the residue ramaining after dissolution of the nickel sulphide button in concentrated hydrochloric acid. Losses for the platinum group elements during this dissolution step are usually insignificant, except when the elements are present at ultra-trace levels. The can be recovered from the filtrate by coprecipitation with tellerium. The latter approach also permits determination of silver, which is significantly lost in the hydrochloric acid treatment (recovery <98% instead of typically ≈ 10%). The coprecipitation with tellurium considerably improves the results for gold (recovery ≈ 95% instead of typically 75%).
Address
Corporate Author Thesis
Publisher Place of Publication (up) Amsterdam Editor
Language Wos A1987K058900006 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 4.513 Times cited 49 Open Access
Notes Approved no
Call Number UA @ lucian @ c:irua:111403 Serial 670
Permanent link to this record
 

 
Author Gijbels, R.; Dams, R.
Title Determination of silicon in natural and pollution aerosols by 14-MeV neutron activation analysis Type A1 Journal article
Year 1973 Publication Analytica chimica acta Abbreviated Journal Anal Chim Acta
Volume 63 Issue 2 Pages 369-381
Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Abstract The determination of silicon via the 28Si(n,p)28 Al reaction by means of 14-MeV neutrons is applied to the analysis of pollution and natural aerosols. A Whatman 41 filter (40 cm2) on which airborne particulate material has been collected is compressed into a 3 × 12.7 mm pellet. Standards are prepared in the same way from clean filters spiked with a silicate solution. After a 50-s irradiation and a 75-s decay time, the sample is counted for 2 min with 5 × 5 NaI(Tl) well detector. The 1.779-MeV photopeak of 28Al is measured with a single channel sealer chain or with a multichannel analyser. The reproducibility, sensitivity and liability to interference from other elements were investigated for both counting systems. The homogeneity of the pellets and the filters was checked. The overall precision of one single-channel determination was estimated to be 3.5% after a 24-h high-volume sampling time. Samples collected in urban, industrial and remote areas with concentrations ranging from 0.05 to 15 μg Si m-3 air were analysed and the results are discussed.
Address
Corporate Author Thesis
Publisher Place of Publication (up) Amsterdam Editor
Language Wos A1973O944700013 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 4.513 Times cited 16 Open Access
Notes Approved no
Call Number UA @ lucian @ c:irua:116365 Serial 672
Permanent link to this record
 

 
Author van Grieken, R.; Gijbels, R.; Speecke, A.; Hoste, J.
Title The determination of silicon in steel by 14-mev neutron activation analysis Type A1 Journal article
Year 1968 Publication Analytica chimica acta Abbreviated Journal Anal Chim Acta
Volume 43 Issue Pages 199-209
Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract A fast (25 min) non-destructive determination of silicon in steel by 14-MeV neutron activation is described. The 1.78-MeV 28Al activity, induced by the reaction 28Si(n,p)28Al, is counted on a NaI(Tl) detector. An oxygen flux monitor is used to normalise to the same neutron flux. Two methods are described to correct for the 56Mn activity (2.58 h), induced into the iron matrix via 56Fe(n,p)56Mn. Nuclear interferences of phosphorus and aluminium have been examined. Special attention has been paid to stainless steels. A sensitivity of 0.02 to 0.05% of silicon is obtained. The precision is 2 to 3% for steels containing above 1% silicon, and 7% for 0.1% of silicon.
Address
Corporate Author Thesis
Publisher Place of Publication (up) Amsterdam Editor
Language Wos A1968C007600004 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 4.513 Times cited 19 Open Access
Notes Approved no
Call Number UA @ lucian @ c:irua:116357 Serial 673
Permanent link to this record
 

 
Author van Grieken, R.; Gijbels, R.; Speecke, A.; Hoste, J.
Title Internal standard activation analysis of silicon in steel Type A1 Journal article
Year 1968 Publication Analytica chimica acta Abbreviated Journal Anal Chim Acta
Volume 43 Issue Pages 381-395
Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Non-destructive 14-MeV neutron activation analysis for silicon in steel has been applied with 56Mn as internal standard.56Mn is formed from the iron matrix via the 56Fe(n,p)56Mn reaction. Several methods of internal standardisation via56Mn are discussed. The 0.84-MeV photopeak of 56Mn is recommended if steel samples of about the same composition are to be analysed. Chemically analysed steel samples are used as silicon standards. A precision of 0.7% was obtained for an analysis plus standardisation time of 13 min. Special attention was paid to interferences produced by concentration changes of impurity elements. Several possible sources of errors were investigated.
Address
Corporate Author Thesis
Publisher Place of Publication (up) Amsterdam Editor
Language Wos A1968C185100003 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 4.513 Times cited 14 Open Access
Notes Approved no
Call Number UA @ lucian @ c:irua:116358 Serial 1701
Permanent link to this record
 

 
Author Struyf, H.; van Roy, W.; van Vaeck, L.; van Grieken, R.; Gijbels, R.; Caravatti, P.
Title Laser microprobe Fourier transform mass spectrometer with external ion source for organic and inorganic microanalysis Type A1 Journal article
Year 1993 Publication Analytica chimica acta Abbreviated Journal Anal Chim Acta
Volume 283 Issue Pages 139-151
Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication (up) Amsterdam Editor
Language Wos A1993MK02800013 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 4.513 Times cited 17 Open Access
Notes Approved no
Call Number UA @ lucian @ c:irua:6141 Serial 1793
Permanent link to this record
 

 
Author Vandecasteele, C.; van Grieken, R.; Gijbels, R.; Speecke, A.
Title Systematic errors in 14-MeV neutron activation analysis for oxygen : part 1 : neutron and γ-ray attenuation effects Type A1 Journal article
Year 1973 Publication Analytica chimica acta Abbreviated Journal Anal Chim Acta
Volume 64 Issue 2 Pages 187-196
Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract A detailed account is given of neutron and γ-ray attenuation effects in 14-MeV neutron activation analysis of oxygen. Appropriate neutron cross-section values have been determined in two different ways and compared with literature values. It appears that the attenuation process is best described in terms of nonelastic scattering cross-sections. It is also shown that the narrow beam total γ-ray attenuation coefficients at 6 MeV, given in the literature are suitable for correction purposes if 16N γ-rays are counted with a window of 4.56.5 MeV. Attention was paid to the contribution of β-rays when the 16N activity is counted in this energy interval with a NaI(Tl) detector.
Address
Corporate Author Thesis
Publisher Place of Publication (up) Amsterdam Editor
Language Wos A1973P353000003 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 4.513 Times cited 11 Open Access
Notes Approved CHEMISTRY, PHYSICAL 54/144 Q2 # PHYSICS, ATOMIC, MOLECULAR & CHEMICAL 9/35 Q2 #
Call Number UA @ lucian @ c:irua:116363 Serial 3464
Permanent link to this record
 

 
Author Vandecasteele, C.; van Grieken, R.; Gijbels, R.; Speecke, A.
Title Systematic errors in 14-MeV neutron activation analysis for oxygen : part 2 : a general standardization method for the determination of oxygen Type A1 Journal article
Year 1973 Publication Analytica chimica acta Abbreviated Journal Anal Chim Acta
Volume 65 Issue 1 Pages 1-17
Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract A general standardization method is described for the determination of oxygen in solid samples via the 16O(n,p)16N reaction. Two systems of flux monitoring are considered: the sample versus standard comparator method and BF3 monitoring. The average flux in sample and standard, fast neutron shielding, fast neutron scattering, absorption of fast neutrons, absorption of 16N γ-rays and counting efficiency of sample and standard are considered. The influence of the target diameter on the obtained correction factors has also been studied. Total achievable accuracy is believed to be about 1%.
Address
Corporate Author Thesis
Publisher Place of Publication (up) Amsterdam Editor
Language Wos A1973Q019300001 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 4.513 Times cited 12 Open Access
Notes Approved
Call Number UA @ lucian @ c:irua:116364 Serial 3465
Permanent link to this record