|
“Pixe analysis of aerosol samples collected over the atlantic-ocean from a sailboat”. Maenhaut W, Selen A, van Espen P, Van Grieken R, Winchester WJ, Nuclear instruments and methods 181, 399 (1981). http://doi.org/10.1016/0029-554X(81)90640-6
Abstract: Size-fractionated aerosol samples, collected over the Atlantic Ocean, were analyzed for up to 20 elements by PIXE. Using a sailboat as sampling platform, duplicate samples were taken for two-day periods by means of battery operated 6-stage cascade impactors, positioned about 8 m above the sea surface. In the PIXE analysis of the fine particle stages (stages 3 to 5) a 5 times smaller beam size was used than for stages 1 and 2. This led to significant improvement in the detection limits for the former stages. The results from the duplicate impactor samples were normally in good agreement, indicating that the combined uncertainty of sampling and PIXE analysis was of the order of 20%. The precision of the PIXE analysis alone was investigated by rebombarding some samples six months after the first analysis. The trends with time of the fine particle sulfur and the coarse particle iron concentrations are discussed in some detail.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0029-554X(81)90640-6
|
|
|
“Platinum : environmental pollution and health effects”. Bencs L, Ravindra K, Van Grieken R page 580 (2011).
Keywords: H2 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Platinum group elements in the environment and their health risk”. Ravindra K, Bencs L, Van Grieken R, The science of the total environment 318, 1 (2004). http://doi.org/10.1016/S0048-9697(03)00372-3
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0048-9697(03)00372-3
|
|
|
“Polarized-beam high-energy EDXRF in geological samples”. Čevik U, Akbulut S, Makarovska Y, Van Grieken R, Spectroscopy letters 46, 36 (2013). http://doi.org/10.1080/00387010.2012.661015
Abstract: Certified reference materials (NIST 1645, BCR 143, IAEA 7, BCR 141, NIESCRM02, and IAEA 375) were used for determining the performance of a secondary target energy-dispersive X-ray fluorescence (EDXRF) spectrometer, Epsilon 5 (PANalytical, Almelo, the Netherlands). For the evaluation of the EDXRF spectra with polarized-beam high-energy excitation, the WinAxil software package has been applied. The results showed that Epsilon 5, EDXRF spectrometry is favorable for the determination of elemental concentrations in geological samples, but the sample preparation has the largest influence on the precision. However, they presented good agreement with certified values for most of the elements.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/00387010.2012.661015
|
|
|
“Polydopamine-gelatin as universal cell-interactive coating for methacrylate-based medical device packaging materials : when surface chemistry overrules substrate bulk properties”. Van de Walle E, Van Nieuwenhove I, Vanderleyden E, Declercq H, Gellynck K, Schaubroeck D, Ottevaere H, Thienpont H, De Vos WH, Cornelissen M, Van Vlierberghe S, Dubruel P, Biomacromolecules 17, 56 (2016). http://doi.org/10.1021/ACS.BIOMAC.5B01094
Abstract: Despite its widespread application in the fields of ophthalmology, orthopedics and dentistry and the stringent need for polymer packagings that induce in vivo tissue integration, the full potential of poly(methyl methacrylate) (PMMA) and its derivatives as medical device packaging material has not been explored yet. We therefore elaborated on the development of a universal coating for methacrylate-based materials which ideally should reveal cell-interactivity irrespective of the polymer substrate bulk properties. Within this perspective, the present work reports on the UV-induced synthesis of PMMA and its more flexible poly(ethyleneglycol) (PEG)-based derivative (PMMAPEG) and its subsequent surface decoration using polydopamine (PDA) as well as PDA combined with gelatin B (Gel B). Successful application of both layers was confirmed by multiple surface characterization techniques. The cell interactivity of the materials was studied by performing live-dead assays and immunostainings of the cytoskeletal components of fibroblasts. It can be concluded that only the combination of PDA and Gel B yields materials posessing similar cell interactivities, irrespective of the physicochemical properties of the underlying substrate. The proposed coating outperforms both the PDA functionalized and the pristine polymer surfaces. A universal cell-interactive coating for methacrylate-based medical device packaging materials has thus been realized.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/ACS.BIOMAC.5B01094
|
|
|
“Possibilities of energy-resolved X-ray radiography for the investigation of paintings”. Cabal Rodríguez AE, Leyva Pernia D, Schalm O, van Espen PJM, Analytical and bioanalytical chemistry 402, 1471 (2012). http://doi.org/10.1007/S00216-011-5230-X
Abstract: X-ray radiographic images of paintings often show little or no contrast. In order to increase the contrast in radiographic images we measured the X-ray spectrum of a low power X-ray tube, after passing through the painting, with a high energy-resolution SDD detector. To obtain images, the detector is collimated with a 400 mu m diameter pinhole and the painting was moved through the beam in the x and y-direction using a dwell time of a few seconds per pixel. The data obtained consists of a data cube of, typically, 200 x 200 pixels and a 512-channel X-ray spectrum for each pixel, spanning the energy range from 0 to 40 keV. Having the absorbance spectrum available for each pixel, we are able, a posteriori, to produce images by edge subtraction for any given element. In this way high contrast, element-specific, images can be obtained. Because of the high energy-resolution a much simpler edge subtraction algorithm can be applied. We also used principal-component imaging to obtain, in a more automated way, images with high contrast. Some of these images can easily be attributed to specific elements. It turns out that preprocessing of the spectral data is crucial for the success of the multivariate image processing.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00216-011-5230-X
|
|
|
“Potentiometric detection in UPLC as an easy alternative to determine cocaine in biological samples”. Daems D, van Nuijs ALN, Covaci A, Hamidi-Asl E, Van Camp G, Nagels LJ, Biomedical chromatography 29, 1124 (2015). http://doi.org/10.1002/BMC.3400
Abstract: The analytical methods which are often used for the determination of cocaine in complex biological matrices are a prescreening immunoassay and confirmation by chromatography combined with mass spectrometry. We suggest an ultra-high-pressure liquid chromatography combined with a potentiometric detector, as a fast and practical method to detect and quantify cocaine in biological samples. An adsorption/desorption model was used to investigate the usefulness of the potentiometric detector to determine cocaine in complex matrices. Detection limits of 6.3ngmL(-1) were obtained in plasma and urine, which is below the maximum residue limit (MRL) of 25ngmL(-1). A set of seven plasma samples and 10 urine samples were classified identically by both methods as exceeding the MRL or being inferior to it. The results obtained with the UPLC/potentiometric detection method were compared with the results obtained with the UPLC/MS method for samples spiked with varying cocaine concentrations. The intraclass correlation coefficient was 0.997 for serum (n =7) and 0.977 for urine (n =8). As liquid chromatography is an established technique, and as potentiometry is very simple and cost-effective in terms of equipment, we believe that this method is potentially easy, inexpensive, fast and reliable. Copyright (c) 2014 John Wiley & Sons, Ltd.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre
DOI: 10.1002/BMC.3400
|
|
|
“Precise gamma ray measurement of the radial distribution of a cracking catalyst at diluted concentrations in a glass riser”. Dantas CC, Dos Santos VA, Melo ACBA, Van Grieken R, Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms 251, 201 (2006). http://doi.org/10.1016/J.NIMB.2006.05.009
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.NIMB.2006.05.009
|
|
|
“Preconcentration and XRF-determination of heavy metals in hair from Sudanese populations”. Eltayeb MAH, Van Grieken RE, Journal of radioanalytical and nuclear chemistry 131, 331 (1989). http://doi.org/10.1007/BF02060598
Abstract: Energy-dispersive X-ray fluorescence analysis was applied for the analysis of hair. The hair samples were digested in a mixture of nitric and perchloric acid and the heavy metals were precipitated with ammonium pyrrolidine dithiocarbamate. The accuracy, precision and recovery of the method for the elements Fe, Ni, Cu, Zn and Pb were evaluated through the analysis of a standard hair sample. The procedure was applied to the analysis of hair from an occupationally exposed group of Sudanese workers and a control group. The hair of the exposed group showed a range of 80550 ppm Fe, 612 ppm Cu, 57190 ppm Zn and 703700 ppm Pb, while that of the control group had a range of 60310 ppm Fe, 722 ppm Cu, 89170 ppm Zn and 317 ppm Pb.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02060598
|
|
|
“Preconcentration methods for the analysis of liquid samples by X-ray fluorescence techniques”. Marguí, E, Van Grieken R, Fontàs C, Hidalgo M, Queralt I, Applied spectroscopy reviews 45, 179 (2010). http://doi.org/10.1080/05704920903584198
Abstract: This article gives an overview of the state-of-the-art of multi-element and single-element preconcentration procedures prior to X-ray fluorescence (XRF) analysis of liquid samples. Many of these preconcentration methods were developed long ago and the purpose of this review is to present some new efficient variations of these methods and new techniques extending the possibilities of XRF for liquid solutions analysis. In addition, trends and future perspectives in this domain are also commented on and discussed in the last section of the review.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/05704920903584198
|
|
|
“Preconcentration methods for the analysis of water by X-ray spectrometric techniques”. Van Grieken R, Analytica chimica acta 143, 3 (1982). http://doi.org/10.1016/S0003-2670(01)95486-8
Abstract: All published procedures for multi-element preconcentration of trace elements, prior to x-ray fluorescence analysis of water, are reviewed and critically evaluated. Most preconcentration methods applied to the determination of single elements in water are also listed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)95486-8
|
|
|
“Prediction of Mα/L&alpha, intensity ratios and the use in the spectra evaluation”. Trincavelli J, Montoro S, Van Grieken R, van Espen P, (1992)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
|
|
“Preliminary evaluation of micro-Raman spectrometry for the characterization of individual aerosol particles”. Potgieter-Vermaak SS, Van Grieken R, Applied spectroscopy 60, 39 (2006). http://doi.org/10.1366/000370206775382848
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1366/000370206775382848
|
|
|
“Preliminary experiment of total reflection x-ray fluorescence using two glancing x-ray beams excitation”. Tsuji K, Sato T, Wagatsuma K, Claes M, Van Grieken R, The review of scientific instruments 70, 1621 (1999). http://doi.org/10.1063/1.1149687
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1063/1.1149687
|
|
|
“Preliminary experiments on grazing-exit electron probe microanalysis (GE-EPMA)”. Tsuji K, Spolnik Z, Wagatsuma K, Nullens R, Van Grieken RE, , 119 (1999)
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Preliminary LAMMA investigations on healthy and acid rain affected spruce needles”. Goossenaerts C, Verbueken A, Van Grieken R, (1986)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Preliminary studies on the geochemistry of the Cauvery river basin”. Subramanian V, Van 't dack L, Van Grieken R, Proceedings of the Indian Academy of Sciences: earth and planetary sciences 94, 99 (1985). http://doi.org/10.1007/BF02871942
Abstract: Samples of water and sediments were collected over a three year period from the entire region of Cauvery river basin excluding the estuary. On the basis of our observations, we have calculated the average composition of the Cauvery river at several locations from the catchment to the river mouth, the downstream profile of sediment load, annual erosion rates, solute and sediment fluxes and have predicted on long term changes. The sediment chemistry was determined by x-ray fluorescence (xrf) technique, and calculated mean compositions of the Cauvery and its tributary bed and the suspended sediment were compared to those of world average river sediments. Downstream profiles of some of the elements appear to be controlled by size and mineralogical characteristics besides local factors specific to the location of the samples. Interelemental relationships indicated good correlation among the transition elements indicating their co-genetic behaviour within the drainage basin.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02871942
|
|
|
“Preparation of conducting electrodes from biological samples for multi-element trace analysis by spark-source mass spectrometry or emission spectrometry”. Vos L, Van Grieken R, Analytica chimica acta 164, 83 (1984). http://doi.org/10.1016/S0003-2670(00)85619-6
Abstract: Four decomposition procedures frequently used for biological material (dry ashing, open wet digestion, wet digestion in a teflon bomb and low-temperature ashing) are optimized for the conversion of biological samples to conducting electrodes suitable for multi-element trace determinations by spark-source mass spectrometry or emission spectrometry. The optimized procedures are evaluated with respect to contamination, retention and preconcentration of the trace elements, homogeneity of the electrodes and precision of the final results. Both dry-ashing methods are prone to losses by volatilization; simple dry ashing suffers from contamination problems during electrode preparation. Wet digestion gives better precision; digestion with nitric/sulfuric acids in an open flask is the method of choice for most elements being simpler and giving lower blanks than the bomb method.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(00)85619-6
|
|
|
“Present and future applications of beam techniques in environmental microanalysis”. Jambers W, Van Grieken R, Trends in analytical chemistry 15, 114 (1996). http://doi.org/10.1016/0165-9936(95)00098-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0165-9936(95)00098-4
|
|
|
“The processes dominating Ca dissolution of limestone when exposed to ambient atmospheric conditions as determined by comparing dissolution models”. Cardell Fernandez C, Cardell-Fernandez C, Vleugels G, Torfs K, Van Grieken R, Environmental geology 43, 160 (2002). http://doi.org/10.1007/S00254-002-0640-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00254-002-0640-X
|
|
|
“Processing of three-dimensional microscopic X-ray fluorescence data”. Vekemans B, Vincze L, Brenker FE, Adams F, Journal of analytical atomic spectrometry 19, 1302 (2004). http://doi.org/10.1039/B404300F
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/B404300F
|
|
|
“Progress in Belgian oceanographic research : proceedings of symposium, Brussels, 3-5 March 1985”. Van Grieken R, Wollast R page 479 p. (1985).
Keywords: ME3 Book as editor; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Progress in laboratory grazing emission X-ray fluorescence spectrometry”. Claes M, de Bokx P, Van Grieken R, X-ray spectrometry 28, 224 (1999). http://doi.org/10.1002/(SICI)1097-4539(199907/08)28:4<224::AID-XRS337>3.3.CO;2-W
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/(SICI)1097-4539(199907/08)28:4<224::AID-XRS337>3.3.CO;2-W
|
|
|
“Progress toward catalytic micro- and nanomotors for biomedical and environmental applications”. Safdar M, Khan SU, Jänis J, Advanced Materials 30, 1703660 (2018). http://doi.org/10.1002/ADMA.201703660
Abstract: Synthetic micro‐ and nanomotors (MNMs) are tiny objects that can autonomously move under the influence of an appropriate source of energy, such as a chemical fuel, magnetic field, ultrasound, or light. Chemically driven MNMs are composed of or contain certain reactive material(s) that convert chemical energy of a fuel into kinetic energy (motion) of the particles. Several different materials have been explored over the last decade for the preparation of a wide variety of MNMs. Here, the discovery of materials and approaches to enhance the efficiency of chemically driven MNMs are reviewed. Several prominent applications of the MNMs, especially in the fields of biomedicine and environmental science, are also discussed, as well as the limitations of existing materials and future research directions.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/ADMA.201703660
|
|
|
“Protection of stone monuments using a brushing treatment with ammonium oxalate”. Mudronja D, Vanmeert F, Fazinic S, Janssens K, Tibljas D, Desnica V, Coatings 11, 379 (2021). http://doi.org/10.3390/COATINGS11040379
Abstract: Stone monuments and buildings are susceptible to weathering. Carbonate-based stones are especially vulnerable in acidic environments, whereas magmatic acidic stones are more susceptible to chemical weathering in basic environments. To slow down surface corrosion of limestone and marble artworks/buildings, protective coatings which inhibit calcite dissolution have been proposed. In this work, samples from two stone types with different porosity were treated with ammonium oxalate (AmOx) to create a protective layer of calcium oxalate (CaOx) using the previously developed brushing method. Two different synchrotron microscopy experiments were performed to determine its protective capability. X-ray powder diffraction (SR-mu-XRPD) in transmission geometry allowed visualization of the distributions of calcium carbonate and oxalates along the sample depths. In a second step, X-ray fluorescence (SR-mu-XRF) was used to check the efficiency/integrity of the protective surface coating layer. This was done by measuring the sulfur distribution on the stone surface after exposing the protected stones to sulfuric acid. XRPD showed the formation of a protective oxalate layer with a thickness of 5-15 mu m on the less porous stone, while a 20-30 mu m thick layer formed on the more porous stone. The XRF study showed that the optimal treatment time depends on the stone porosity. Increasing the treatment time from 1 to 3 h resulted in a decreased efficiency of the protective layer for the low porosity stone. We assume that this is due to the formation of vertical channels (cracks) in the protective layer.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.175
DOI: 10.3390/COATINGS11040379
|
|
|
“Quantification in grazing-emission X-ray fluorescence spectrometry”. Spolnik ZM, Claes M, Van Grieken RE, de Bokx PK, Urbach HP, Spectrochimica acta: part B : atomic spectroscopy 54, 1525 (1999). http://doi.org/10.1016/S0584-8547(99)00051-8
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(99)00051-8
|
|
|
“Quantification in XRF analysis of intermediate-thickness samples”. Markowicz AA, Van Grieken RE page 407 (2002).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Quantification in XRF analysis of intermediate-thickness samples”. Markowicz AM, Van Grieken RE page 339 (1992).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Quantification of boron in cells for evaluation of drug agents used in boron neutron capture therapy”. Verlinden B, Van Hoecke K, Aerts A, Daems N, Dobney A, Janssens K, Cardinaels T, Journal Of Analytical Atomic Spectrometry 36, 598 (2021). http://doi.org/10.1039/D0JA00456A
Abstract: Boron neutron capture therapy (BNCT) is an extensively studied radiotherapeutic strategy for cancer treatment. BNCT is based on irradiation of malignant tumour cells with neutrons after uptake of a B-10 containing molecule. Alpha particles, locally produced by neutron irradiation kill the cancer cells. Important for ongoing research regarding cellular uptake and cytotoxicity of a large variety of B-10 containing molecules is the accurate determination of boron concentrations in cell cultures. In this work, the sample preparation for quantitative inductively coupled plasma mass spectrometry (ICP-MS) analysis on cell cultures was optimized. By making use of acid digestion combined with UV digestion, low detection limits (0.4 mu g L-1) and full recoveries of boron could be achieved while measurements were free of spectral and non-spectral interferences. Finally, cell-associated boron in the form of 4-borono-l-phenylalanine (l-BPA) in vascular endothelial cell cultures could be determined with ICP-MS as (1.26 +/- 0.10) x 10(9) boron atoms per cell. The developed method can prove its importance for further BNCT research and elemental analysis of cell cultures.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
DOI: 10.1039/D0JA00456A
|
|
|
“Quantification problems in light element determination by grazing emission X-ray fluorescence”. Kuczumow A, Claes M, Schmeling M, Van Grieken R, de Gendt S, Journal of analytical atomic spectrometry 15, 415 (2000). http://doi.org/10.1039/A908724I
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/A908724I
|
|