“Trace analysis of estuarine brown algae by energy-dispersive X-ray fluorescence”. Sauter L, Van der Ben D, Van Grieken R, X-ray spectrometry 8, 159 (1979). http://doi.org/10.1002/XRS.1300080405
Abstract: Brown algae, which are good indicators for estuarine metal pollution, can advantageously be analysed by energy-dispersive X-ray fluorescence. The use of thin film samples and samples of intermediate thickness has several advantages over the conventional thick pellet procedure. A quite homogeneous thin target is prepared by suspending 15 mg of dried and ground seaweed powder in bi-distilled water and evaporating the slurry on a 10 cm2 Mylar foil held in a Teflon ring. The effective sample weight in the beam is calculated by a procedure based on the scatter peaks in the spectrum. Sensitivities are typically in the 215 ppm range. The coefficient of variation per analysis averaged over ten elements amounts to 10%. The natural concentration variation in seaweed specimens at one location is 13%. Samples from locations in the more polluted western Scheldt estuary yield significantly higher values for several elements, relative to the eastern Scheldt sites. Possible trace element variations between the top and base of plants, and between different seaweed specimens and sampling seasons, are discussed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300080405
|
|
|
“Use of theoretical accurate binary influence coefficients with Tertian's equation in X-ray fluorescence analysis of silicate rocks in borax glass beads”. Muia LM, Van Grieken R, X-ray spectrometry 19, 141 (1990). http://doi.org/10.1002/XRS.1300190311
Abstract: A study of the suitability of the Tertian algorithm using new accurate binary influence coefficients and a comparison standard for x-ray fluorescence analysis of geological materials prepared as borax glass beads was performed. The algorithm was found to give satisfactory results for the analysis of four major components in geological materials. Even in the worst case, when there is a factor of 20 difference in the concentration in the specimen and a comparison standard, the algorithm gives results which differ from the true results by a factor of about 2. This makes the algorithm attractive as a diagnostic tool in analyses of unknown specimens and in the identification of appropriate standards. The binary coefficients are easily calculated so that the algorithm can be implemented on a minicomputer.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300190311
|
|
|
“EXRS2022 : the 2022 edition of the European X-ray Spectrometry conference, held in Bruges, Belgium”. Janssens K, X-ray spectrometry 52, 276 (2023). http://doi.org/10.1002/XRS.3386
Keywords: Editorial; Antwerp X-ray Imaging and Spectroscopy (AXIS)
Impact Factor: 1.2
DOI: 10.1002/XRS.3386
|
|
|
“Comparison of four mobile, non‐invasive diagnostic techniques for differentiating glass types in historical leaded windows : MA‐XRF , UV–Vis–NIR, Raman spectroscopy and IRT”. Cagno S, van der Snickt G, Legrand S, Caen J, Patin M, Meulebroeck W, Dirkx Y, Hillen M, Steenackers G, Rousaki A, Vandenabeele P, Janssens K, X-Ray Spectrometry , xrs.3185 (2020). http://doi.org/10.1002/XRS.3185
Abstract: This paper critically compares the performance of four non-invasive techniques that match the accuracy, flexibility, time-efficiency, and transportability required for in situ characterization of leaded glass windows: macroscopic X-ray fluorescence imaging (MA-XRF), UV-Vis-NIR, Raman spectroscopy, and infrared thermography (IRT). In order to compare the techniques on equal grounds, all techniques were tested independently of each other by separate research groups on the same historical leaded window tentatively dated to the 17th century, without prior knowledge. The aim was to assess the ability of these techniques to document the conservation history of the window by classifying and grouping the colorless glass panes, based on differences in composition. IRT, MA-XRF and UV-Vis-NIR spectroscopy positively distinguished at least two glass groups, with MA-XRF providing the most detailed chemical information. In particular, based on the ratio between the network modifier (K) and network stabilizer (Ca) and on the level of colorants and decolorizers (Fe, Mn, As), the number of plausible glass families could be strongly reduced. In addition, UV-Vis-NIR detected cobalt at ppm level and gave more specific information on the chromophore Fe2+/Fe(3+)ratio. Raman spectroscopy was hampered by fluorescence caused by the metal ions of the decolorizer in most of the panes, but nevertheless identified one group as HLLA.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
Impact Factor: 1.2
DOI: 10.1002/XRS.3185
|
|
|
“Interpreting technical evidence from spectral imaging of paintings by Edouard Manet in the Courtauld Gallery”. Amato SR, Burnstock A, Cross M, Janssens K, Rosi F, Cartechini L, Fontana R, Dal Fovo A, Paolantoni M, Grazia C, Romani A, Michelin A, Andraud C, Tournie A, Dik J, X-ray spectrometry
T2 –, MA-XRF Workshop on Developments and Applications of Macro-XRF in, Conservation, Art, and Archeology, SEP 24-25, 2017, Trieste, ITALY 48, 282 (2019). http://doi.org/10.1002/XRS.2828
Abstract: The paintings by edouard Manet in The Courtauld Gallery Dejeuner sur l'herbe (1863-68), Marguerite de Conflans en Toilette de Bal (1870-1880), Banks of the Seine at Argenteuil (1874), and A Bar at the Folies-Bergere (1882) were investigated for the first time using a range of non-invasive in situ analyses. The aims of the study were to investigate the painting techniques and materials used for this group of works and to critically evaluate the technical evidence derived from the integrated use of imaging techniques and portable spectroscopic methods in this context. The paintings were investigated by means of macro X-ray fluorescence (MA-XRF), reflection spectral imaging, portable UV-Vis-NIR spectroscopy, portable Raman spectroscopy, and reflection FTIR. MA-XRF and reflection spectral imaging allowed visualising elements in the compositions that were not visible using traditional methods of technical study. For example, MA-XRF analysis of Dejeuner sur l'herbe revealed elements of the development of the composition that provided new evidence to consider its relationship to other versions of the composition. The study also highlighted questions about the interpretation of elemental distribution maps and spectral images that did not correspond to the reworking visible in X-radiographs. For example, in A Bar at the Folies-Bergere Manet made numerous changes during painting, which were not clearly visualised with any of the techniques used. The research has wider implications for the study of Impressionist paintings, as the results will support technical studies of works by other artists of the period who used similar materials and painting methods.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
DOI: 10.1002/XRS.2828
|
|
|
“X-ray spectrometry applied for characterization of bricks of Brazilian historical sites”. Asfora VK, Bueno CC, de Barros VM, Khoury H, Van Grieken R, X-Ray Spectrometry , 1 (2020). http://doi.org/10.1002/XRS.3194
Abstract: This paper presents the results of X-ray fluorescence (XRF) analysis of bricks sampled from historical places in Pernambuco, a state in the northeastern region of Brazil. In this study, twenty bricks found in historical sites were analyzed. Two bricks made in the 17th century, presumably used as ballast in ships coming from Holland, five locally manufactured bricks: one from 18th century, three from 19th century, and one from 20th century, and thirteen bricks collected from a recent Archeological investigation of Alto da Se, in the town of Olinda. Qualitative determination of the chemical elements present in the samples was undertaken using a self-assembled portable XRF system based on a compact X-ray tube and a thermoelectrically cooled Si-PIN photodiode system, both commercially available. X-ray diffraction analysis was also carried out to assess the crystalline mineral phases present in the bricks. The results showed that quartz (SiO2) is the major mineral content in all bricks. Although less expressive in the XRD patterns, mineral phases of illite, kaolinite, anorthite, and rutile are also identified. The trace element distribution patterns of the bricks, determined by the XRF technique, is dominated by Fe and, in decreasing order, by K, Ti, Ca, Mn, Zr, Rb, Sr, Cr, and Y with slight differences among them. Analyses of the chemical compositional features of the bricks, evaluated by principal component analysis of the XRF datasets, allowed the samples to be grouped into five clusters with similar chemical composition. These cluster groups were able to identify both age and manufacturing sites. Dutch bricks prepared with different geological clays compositions were defined.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.2
DOI: 10.1002/XRS.3194
|
|
|
“Semi-quantitative analysis of the formation of a calcium oxalate protective layer for monumental limestone using combined micro-XRF and micro-XRPD”. Vanmeert F, Mudronja D, Fazinic S, Janssens K, Tibljas D, X-ray spectrometry 42, 256 (2013). http://doi.org/10.1002/XRS.2486
Abstract: A current method for the protection of cretaceous limestone present in various monuments consists of performing a passivating treatment with ammonium oxalate (AmOx). A calcium oxalate protective layer is formed on the surface and enhances the acid resistance of the stone. The in-depth formation of the calcium oxalate layer was investigated on cross sections by using combined micro X-ray fluorescence and micro X-ray powder diffraction (mu XRF/mu XRPD). XRPD showed the presence of both whewellite and weddellite in the calcite stone matrix. A correction was made for sample misalignment, which was visible in both the fluorescence and the diffraction line measurements. A semi-quantitative analysis was performed on the basis of Klug's equation for a two-phase mixture (the presence of weddellite was neglected) without the need for a known reference sample. By assuming two extreme compositions for a reference weight fraction (1 and 99wt%), it was possible to obtain whewellite concentration profiles, which can be used for comparing the effectiveness of different methods for the application of AmOx to the stone surface and the effect of treatment time and AmOx concentration used. It is shown that for the relative amounts of whewellite formed, the differences due to the assumed weight fractions are smaller than the errors due to sample heterogeneity and preferred orientation. Copyright (c) 2013 John Wiley & Sons, Ltd.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 5
DOI: 10.1002/XRS.2486
|
|
|
“James Ensor's pigment use: artistic and material evolution studied by means of portable X-ray fluorescence spectrometry”. van der Snickt G, Janssens K, Schalm O, Aibéo C, Kloust H, Alfeld M, X-ray spectrometry 39, 103 (2010). http://doi.org/10.1002/XRS.1235
Abstract: In this paper, portable X-ray fluorescence spectrometry (PXRF) was employed as a screening tool for determining and comparing the pigment use in a large series of paintings by the Belgian artist James Ensor (1860-1949). Benefits and drawbacks of PXRF as a method, and the instrument employed, are discussed from a practical, conservation and instrumental perspective. Regardless of several restrictions due to the set-up and/or the analytical method, it appeared feasible to document the evolution with time in Ensor's use of inorganic pigments and to correlate this technical evolution with stylistic developments, Nevertheless, it became clear that a full identification of all materials present can only be done by means of the analysis of (cross-sectioned) samples.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 25
DOI: 10.1002/XRS.1235
|
|
|
“Chemical analysis of 16th to 19th century Limoges School painted enamel objects in three museums of the Low Countries”. van der Linden V, Schalm O, Houbraken J, Thomas M, Meesdom E, Devos A, van Dooren R, Nieuwdorp H, Janssen E, Janssens K, X-ray spectrometry 39, 112 (2010). http://doi.org/10.1002/XRS.1207
Abstract: In this study, the results of analysing of a series of 16th-19th century painted enamel objects of the Limoges School currently in collections in three Dutch and Flemish museums by means of portable and micro x-ray fluorescence analysis (PXRF and µ-XRF) and electron probe micro analysis (EPMA) are presented. The aim of the investigation was the authentication of specific pieces. Therefore, the glass compositions as well as the (glass) colouring agents used by the Limoges' artists were studied as a function of the age of the objects. Due to the evolution of these properties, it is possible to approximately date these objects based on their chemical composition. The complete émail peint collection of the Museum Boijmans-Van Beuningen (Rotterdam, The Netherlands), consisting of 20 émail peint plaques, was analysed with µ-XRF. Quantitative information was obtained by EPMA analysis of 15 enamel fragments of objects from museum and private collections in the Low Countries. PXRF analyses were performed on the painted enamel collection of the Antwerp Vleeshuis Museum (13 objects) and the Mayer van den Bergh Museum (4 objects) and on a set of 18 plaques that were donated to the Boijmans-Van Beuningen Museum by a private collector. The results obtained by means of EPMA, µ-XRF and PXRF proved to be useful in the discrimination of 16th century painted enamel objects from those of the19th century. From a total of 70 objects examined, 2 objects (OM964A and OM993) featured a chemical signature that deviated from the published literature composition and pigment use consistent with its presumed period of manufacture.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 8
DOI: 10.1002/XRS.1207
|
|
|
“Preface to the special issue on: MA-XRF “developments and applications of macro-XRF in conservation, art, and archeology&rdquo, (Trieste, Italy, 24 and 25 September 2017)”. Romano FP, Janssens K, X-ray spectrometry 48, 249 (2019). http://doi.org/10.1002/XRS.3047
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
DOI: 10.1002/XRS.3047
|
|
|
“Study of the uniformity of aerosol filters by scanning MA-XRF”. Cabal A, Legrand S, Van den Bril B, Tote K, Janssens K, van Espen P, X-ray spectrometry
T2 –, 17th European Conference on X-Ray Spectrometry (EXRS), JUN 19-24, 2016, Univ Gothenburg, Univ Gothenburg, Gothenburg, SWEDEN 46, 461 (2017). http://doi.org/10.1002/XRS.2767
Abstract: Energy-dispersive X-ray fluorescence (XRF) is an attractive analytical method to determine the level of air pollution by heavy metals. The concentration of the filter in ng/cm(2) is obtained by direct comparison of the net characteristic line intensity of an element with that of a thin film standard. As the sampled area on the filter and the area of the standard are larger than the area analysed by the instrument, the distribution of the elements on the surface of both samples and standards have to be sufficiently uniform. If this is not the case, biased concentration estimates are obtained. Two scanning macro-XRF setups with a beam diameter of similar to 0.5 mm were used to investigate the distribution of elements in (1) commercially available (Micromatter) standards, (2) in-house quartz filter standards obtained with an aerosol generator and (3) particulatematter (PM10) collected on quartz filters by a Leckel SEQ 47/50 sampler. The uniformity of the Micromatter standards was better than 2%. At least some in-house standards showed a concave distribution with less material at the edges. The maximum bias introduced by this is less than 5%. Because of the limited sensitivity of scanning XRF compared with conventional XRF, the distribution of only a few common elements like Ca and Fe could be determined reliably in aerosol filters. The distribution of some heavy elements could only be measured in filters sampled in polluted regions. In general, the loading of particulate matter over the filters was uniform. Copyright (C) 2017 John Wiley & Sons, Ltd.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 4
DOI: 10.1002/XRS.2767
|
|