“Investigation of the electrosynthetic pathway of the aldol condensation of acetone”. Pauwels D, Hereijgers J, Verhulst K, De Wael K, Breugelmans T, Chemical engineering journal 289, 554 (2016). http://doi.org/10.1016/J.CEJ.2016.01.018
Abstract: The potential-controlled electrochemical aldol condensation of acetone to diacetone alcohol in a standard batch electrolysis set-up was studied in this work. It is confirmed that the reaction proceeds at the cathode and that, contrary to what is mentioned in earlier literature, water in the electrolyte has a disadvantageous effect on the reaction. Similar to the chemical reaction, the electrochemical reaction reaches a maximum yield when the equilibrium is reached. Separating the anode and cathode prevents cross-over and degradation of products, leading to a higher yield. Starting with pure acetone and support electrolyte, it was possible to obtain a diacetone alcohol concentration of 15 m% after two hours electrolysis in a divided set-up with a platinum electrode at -2.5 V. The concentration gradient throughout the electrolysis follows an exponential curve up to its equilibrium concentration.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Applied Electrochemistry & Catalysis (ELCAT)
Impact Factor: 6.216
Times cited: 6
DOI: 10.1016/J.CEJ.2016.01.018
|
|
|
“A new multisine-based impedimetric aptasensing platform”. Pauwels D, Pilehvar S, Geboes B, Hubin A, De Wael K, Breugelmans T, Electrochemistry communications 71, 23 (2016). http://doi.org/10.1016/J.ELECOM.2016.07.010
Abstract: In this work an aptamer-based biosensor is combined with a multisine electrochemical impedance spectroscopy sensing methodology into a novel and promising biosensing strategy. Employing a multisine instead of a traditional single sine measuring method allows the detection and quantification of parameters that provide information about the accuracy and reliability of the results, such as noise and distortions. This does not only lead to a shorter measurement time, but it also enables an easy and fast evaluation of the quality of the data and fitting, leading to more accurate results.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Applied Electrochemistry & Catalysis (ELCAT)
Impact Factor: 4.396
Times cited: 1
DOI: 10.1016/J.ELECOM.2016.07.010
|
|
|
“Integration of a photoelectrochemical cell in a flow system for quantification of 4-aminophenol with titanium dioxide”. Mendonça CD, Rahemi V, Hereijgers J, Breugelmans T, Machado SAS, De Wael K, Electrochemistry Communications 117, 106767 (2020). http://doi.org/10.1016/J.ELECOM.2020.106767
Abstract: The photoelectrochemical quantification of phenolic compounds such as hydroquinone (HQ) and 4-aminophenol (4-AP) is accomplished by integrating a photoelectrochemical cell into a flow injection analysis (FIA) setup. It is a well-known fact that during the electroanalysis of phenolic compounds, the electrode surface is susceptible to poisoning. However, electrode fouling can be reduced significantly by using the FIA system with periodic washing of the electrode. Reactive oxygen species (ROS), which are generated on the surface of TiO2 under UV light, can oxidize phenolic compounds such as 4-AP. The oxidized form of 4-AP is reduced back at the electrode surface, generating a measurable signal proportional to its concentration. The factors influencing the perfor-mance of the sensor, such as flow rate, applied potential for back reduction and pH, are investigated in detail. In the concentration range 0.0125-1.0 mu M, a linear correlation between the photocurrent and the concentration of 4-AP was observed with a sensitivity of 0.6 A M-1 cm(-2) and a limit of detection of 18 nM. A straightforward analytical methodology for the on-site, highly sensitive and low-cost quantification of phenolic compounds is presented, based on the use of TiO2 in a photoelectrochemical flow cell.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Applied Electrochemistry & Catalysis (ELCAT)
Impact Factor: 5.4
Times cited: 1
DOI: 10.1016/J.ELECOM.2020.106767
|
|
|
“Bio-nanohybrid gelatin/quantum dots for cellular imaging and biosensing applications”. Samal SK, Soenen S, Puppi D, De Wael K, Pati S, De Smedt S, Braeckmans K, Dubruel P, International journal of molecular sciences 23, 11867 (2022). http://doi.org/10.3390/IJMS231911867
Abstract: The bio-nanohybrid gelatin protein/cadmium sulfide (Gel/CdS) quantum dots (QDs) have been designed via a facile one-pot strategy. The amino acids group of gelatin chelate Cd2+ and grow CdS QDs without any agglomeration. The H-1 NMR spectra indicate that during the above process there are no alterations of the gelatin protein structure conformation and chemical functionalities. The prepared Gel/CdS QDs were characterized and their potential as a system for cellular imaging and the electrochemical sensor for hydrogen peroxide (H2O2) detection applications were investigated. The obtained results demonstrate that the developed Gel/CdS QDs system could offer a simple and convenient operating strategy both for the class of contrast agents for cell labeling and electrochemical sensors purposes.
Keywords: A1 Journal article; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
DOI: 10.3390/IJMS231911867
|
|
|
“An improved electrochemical aptasensor for chloramphenicol detection based on aptamer incorporated gelatine”. Hamidi-Asl E, Dardenne F, Blust R, De Wael K, Sensors 15, 7605 (2015). http://doi.org/10.3390/S150407605
Abstract: Because of the biocompatible properties of gelatine and the good affinity of aptamers for their targets, the combination of aptamer and gelatine type B is reported as promising for the development of biosensing devices. Here, an aptamer for chloramphenicol (CAP) is mixed with different types of gelatine and dropped on the surface of disposable gold screen printed electrodes. The signal of the CAP reduction is investigated using differential pulse voltammetry. The diagnostic performance of the sensor is described and a detection limit of 1.83 x 10(-10) M is found. The selectivity and the stability of the aptasensor are studied and compared to those of other CAP sensors described in literature.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.677
Times cited: 21
DOI: 10.3390/S150407605
|
|
|
“An electrochemical impedimetric aptasensing platform for sensitive and selective detection of small molecules such as chloramphenicol”. Pilehvar S, Dierckx T, Blust R, Breugelmans T, De Wael K, Sensors 14, 12059 (2014). http://doi.org/10.3390/S140712059
Abstract: We report on the aptadetection of chloramphenicol (CAP) using electrochemical impedance spectroscopy. The detection principle is based on the changes of the interfacial properties of the electrode after the interaction of the ssDNA aptamers with the target molecules. The electrode surface is partially blocked due to the formation of the aptamer-CAP complex, resulting in an increase of the interfacial electron-transfer resistance of the redox probe detected by electrochemical impedance spectroscopy or cyclic voltammetry. We observed that the ratio of polarization resistance had a linear relationship with the concentrations of CAP in the range of 1.76127 nM, and a detection limit of 1.76 nM was obtained. The covalent binding of CAP-aptamer on the electrode surface combined with the unique properties of aptamers and impedimetric transduction leads to the development of a stable and sensitive electrochemical aptasensor for CAP.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Applied Electrochemistry & Catalysis (ELCAT)
Impact Factor: 2.677
Times cited: 34
DOI: 10.3390/S140712059
|
|
|
“Redesigning an electrochemical MIP sensor for PFOS : practicalities and pitfalls”. Moro G, Cristofori D, Bottari F, Cattaruzza E, De Wael K, Moretto LM, Sensors 19, 4433 (2019). http://doi.org/10.3390/S19204433
Abstract: There is a growing interest in the technological transfer of highly performing electrochemical sensors within portable analytical devices for the in situ monitoring of environmental contaminants, such as perfluorooctanesulfonic acid (PFOS). In the redesign of biomimetic sensors, many parameters should be taken into account from the working conditions to the electrode surface roughness. A complete characterization of the surface modifiers can help to avoid time-consuming optimizations and better interpret the sensor responses. In the present study, a molecularly imprinted polymer electrochemical sensor (MIP) for PFOS optimized on gold disk electrodes was redesigned on commercial gold screen-printed electrodes. However, its performance investigated by differential pulse voltammetry was found to be poor. Before proceeding with further optimization, a morphological study of the bare and modified electrode surfaces was carried out by scanning electron microscopy-energy-dispersive X-ray spectrometry (SEM-EDS), atomic force microscopy (AFM) and profilometry revealing an heterogeneous distribution of the polymer strongly influenced by the electrode roughness. The high content of fluorine of the target-template molecule allowed to map the distribution of the molecularly imprinted polymer before the template removal and to define a characterization protocol. This case study shows the importance of a multi-analytical characterization approach and identify significant parameters to be considered in similar redesigning studies.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.677
DOI: 10.3390/S19204433
|
|
|
“Electrochemical rapid detection of methamphetamine from confiscated samples using a graphene-based printed platform”. Truta F, Drăgan A-M, Tertis M, Parrilla M, Slosse A, Van Durme F, De Wael K, Cristea C, Sensors 23, 6193 (2023). http://doi.org/10.3390/S23136193
Abstract: Methamphetamine (MAP) is a highly addictive and illegal stimulant drug that has a significant impact on the central nervous system. Its detection in biological and street samples is crucial for various organizations involved in forensic medicine, anti-drug efforts, and clinical diagnosis. In recent years, nanotechnology and nanomaterials have played a significant role in the development of analytical sensors for MAP detection. In this study, a fast, simple, and cost-effective electrochemical sensor is presented that is used for the sensitive detection of MAP in confiscated street samples with a complex matrix. The optimized screen-printed sensor based on a carbon working electrode modified with graphene demonstrated an excellent limit of detection, good sensitivity, and a wide dynamic range (1–500 μM) for the target illicit drug both for standard solutions and real samples (seized samples, tap water, and wastewater samples). It can detect MAP at concentrations as low as 300 nM in real samples. This limit of detection is suitable for the rapid preliminary screening of suspicious samples in customs, ports, airports, and on the street. Furthermore, the sensor exhibits a good recovery rate, indicating its reliability and repeatability. This quality is crucial for ensuring consistent and accurate results during screening processes.
Keywords: A1 Journal article; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
DOI: 10.3390/S23136193
|
|
|
“Electrochemical deposition of a copper carboxylate layer on copper as potential corrosion inhibitor”. Elia A, De Wael K, Dowsett M, Adriaens A, Journal of solid state electrochemistry 16, 143 (2011). http://doi.org/10.1007/S10008-010-1283-6
Abstract: Carboxylic acids and sodium carboxylates are used to protect metals against aqueous and atmospheric corrosion. In this paper, we describe the application of a layer of copper carboxylate on the surface of a copper electrode by means of cyclic voltammetry technique and tests which measure the corresponding resistance to aqueous corrosion. Unlike the soaking process, which also forms a film on the surface, the use of cyclic voltammetry allows one to follow the deposition process of the copper carboxylates onto the electrode. The modified electrodes have been characterised with infrared spectroscopy. In addition, the corrosion resistance of the film has been investigated using polarisation resistance and Tafel plot measurements.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.316
Times cited: 8
DOI: 10.1007/S10008-010-1283-6
|
|
|
“Influence of the deposition method, temperature and deposition time on the corrosion inhibition of lead dodecanoate coatings deposited on lead surfaces”. De Keersmaecker M, De Wael K, Adriaens A, Journal of solid state electrochemistry 17, 1259 (2013). http://doi.org/10.1007/S10008-012-1964-4
Abstract: Electrochemical impedance measurements have been used to investigate the influence of the deposition method, including time and temperature, upon the corrosion inhibition characteristics of lead dodecanoate coatings on lead electrodes. The results were analysed using multivariate statistics and show that, in general, these easily prepared coatings are very protective against corrosion. The temperature proves to be an important parameter for the quality and the corrosion inhibition efficiency of the coating. A comparison between two different electrochemically assisted deposition methods, immersion using a reduction pretreatment and cyclic voltammetry, does not show significant differences. Using the immersion technique at room temperature, the deposition time was tested as the third influencing parameter for the corrosion inhibition efficiency of the deposited lead dodecanoate coatings. A longer deposition time of the lead into the sodium dodecanoate solution provides a layer with a somewhat higher corrosion resistance.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.316
Times cited: 4
DOI: 10.1007/S10008-012-1964-4
|
|
|
“Formation of metallic mercury during photodegradation/photodarkening of \alpha-HgS : electrochemical evidence”. Anaf W, Janssens K, De Wael K, Angewandte Chemie: international edition in English 52, 12568 (2013). http://doi.org/10.1002/ANIE.201303977
Abstract: Das rote Pigment α-HgS neigt in Gegenwart von Licht und Chloridionen zur Schwärzung. Als Grund für die Zersetzung und Entfärbung werden die Bildung von (schwarzem) β-HgS oder Quecksilbermetall vermutet, doch diese Substanzen wurden noch nicht auf natürlich oder künstlich zersetzter HgS-Farbe nachgewiesen. Elektrochemische Experimente belegen nun die Bildung von Quecksilbermetall in Gegenwart von Licht und Chloridionen.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 11.994
Times cited: 19
DOI: 10.1002/ANIE.201303977
|
|
|
“Nanoscale analysis of historical paintings by means of O‐PTIR spectroscopy : the identification of the organic particles in L’Arlésienne (portrait of Madame Ginoux) by Van Gogh”. Beltran V, Marchetti A, Nuyts G, Leeuwestein M, Sandt C, Borondics F, De Wael K, Angewandte Chemie-International Edition 60, 22753 (2021). http://doi.org/10.1002/ANIE.202106058
Abstract: Optical-photothermal infrared (O-PTIR) spectroscopy is a recently developed technique that provides spectra comparable to traditional transmission FTIR spectroscopy with nanometric spatial resolution. Hence, O-PTIR is a promising candidate for the analysis of historical paintings, as well as other cultural heritage objects, but its potential has not yet been evaluated.
Keywords: A1 Journal article; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 11.994
DOI: 10.1002/ANIE.202106058
|
|
|
“Electrochemical sensing of phenicol antibiotics at gold”. Pilehvar S, Dardenne F, Blust R, De Wael K, International journal of electrochemical science 7, 5000 (2012)
Abstract: Phenicols are an effective and a broad spectrum class of antibiotics which has lost favour due to their side effects on human health. A rapid and sensitive electrochemical detection system is developed for the simultaneous detection of chloramphenicol (CAP), thiamphenicol (TAP) and florfenicol (FF). The electrochemical behaviour of CAP in the presence of its derivatives was investigated by cyclic voltammetry (CV) and square wave voltammetry (SWV). At a gold electrode, CAP gives rise to a sensitive cathodic peak at −0.68V (versus SCE) in a tris buffer solution (pH 7.6). This behavior gives us the opportunity to introduce a method for sensing CAP electrochemically in the presence of its derivatives. Calibration graphs were linear in the 2.5-7.4 μmol L-1 concentration range. Deviations from linearity were observed for higher concentrations and this was interpreted to be due to kinetic limitation caused by the saturation of CAP and its reduction products onto the gold electrode surface. A limit of detection of 1 μmol L-1 was found.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.469
|
|
|
“The electrochemistry of a gelatin modified gold electrode”. De Wael K, Verstraete A, van Vlierberghe S, Dejonghe W, Dubruel P, Adriaens A, International journal of electrochemical science 6, 1810 (2011)
Abstract: This paper discusses the electrochemical behaviour of gelatin coated gold electrodes in physiological pH conditions in a potential window −1.5 till 1.0 V vs SCE by performing cyclic voltammetry. A comparison is made between gelatin A and gelatin B, which have respectively a positive and a negative net charge at physiological pH. The deposition of gelatin onto the gold surface is confirmed by means of attenuated total reflection-infrared (ATR-IR) spectroscopic analyses.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.469
|
|
|
“The effect of the buffer solution on the adsorption and stability of horse heart myoglobin on commercial mesoporous titanium dioxide : a matter of the right choice”. Loreto S, Cuypers B, Brokken J, Van Doorslaer S, De Wael K, Meynen V, Physical chemistry, chemical physics 19, 13503 (2017). http://doi.org/10.1039/C6CP08585G
Abstract: Despite the numerous studies on the adsorption of different proteins onto mesoporous titanium dioxide and indications on the important role of buffer solutions in bioactivity, a systematic study on the impact of the buffer on the protein incorporation into porous substrates is still lacking. We here studied the interaction between a commercial mesoporous TiO2 and three of the most used buffers for protein incorporation, i.e. HEPES, Tris and phosphate buffer. In addition, this paper analyzes the adsorption of horse heart myoglobin (hhMb) onto commercial mesoporous TiO2 as a model system to test the influence of buffers on the protein incorporation behavior in mesoporous TiO2. N2 sorption analysis, FT-IR and TGA/DTG measurements were used to evaluate the interaction between the buffers and the TiO2 surface, and the effect of such an interaction on hhMb adsorption. Cyclic voltammetry (CV) and electron paramagnetic resonance (EPR) were used to detect changes in the microenvironment surrounding the heme. The three buffers show a completely different interaction with the TiO2 surface, which drastically affects the adsorption of myoglobin as well as its structure and electrochemical activity. Therefore, special attention is required while choosing the buffer medium to avoid misguided evaluation of protein adsorption on mesoporous TiO2.
Keywords: A1 Journal article; Laboratory of adsorption and catalysis (LADCA); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.123
Times cited: 2
DOI: 10.1039/C6CP08585G
|
|
|
“Transdermal on-demand drug delivery based on an iontophoretic hollow microneedle array system”. Detamornrat U, Parrilla M, Domínguez-Robles J, Anjani QK, Larrañeta E, De Wael K, Donnelly RF, Lab on a chip 23, 2304 (2023). http://doi.org/10.1039/D3LC00160A
Abstract: Transdermal drug delivery has emerged as an alternative administration route for therapeutic drugs, overcoming current issues in oral and parenteral administration. However, this technology is hindered by the low permeability of the stratum corneum of the skin. In this work, we develop a synergic combination of two enhancing technologies to contribute to an improved and on-demand drug delivery through an iontophoretic system coupled with hollow microneedles (HMNs). For the first time, a polymeric HMN array coupled with integrated iontophoresis for the delivery of charged molecules and macromolecules (e.g. proteins) is devised. To prove the concept, methylene blue, fluorescein sodium, lidocaine hydrochloride, and bovine serum albumin-fluorescein isothiocyanate conjugate (BSA-FITC) were first tested in an in vitro setup using 1.5% agarose gel model. Subsequently, the ex vivo drug permeation study using a Franz diffusion cell was conducted, exhibiting a 61-fold, 43-fold, 54-fold, and 17-fold increment of the permeation of methylene blue, fluorescein sodium, lidocaine hydrochloride, and BSA-FITC, respectively, during the application of 1 mA cm(-2) current for 6 h. Moreover, the total amount of drug delivered (i.e. in the skin and receptor compartment) was analysed to untangle the different delivery profiles according to the types of molecule. Finally, the integration of the anode and cathode into an iontophoretic hollow microneedle array system (IHMAS) offers the full miniaturisation of the concept. Overall, the IHMAS device provides a versatile wearable technology for transdermal on-demand drug delivery that can improve the administration of personalised doses, and potentially enhance precision medicine.
Keywords: A1 Journal article; Engineering sciences. Technology; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 6.1
DOI: 10.1039/D3LC00160A
|
|
|
“Synthesis and characterization of heteroleptic rare earth double-decker complexes involving tetradiazepinoporphyrazine and phthalocyanine macrocycles”. Tarakanova EN, Tarakanov PA, Simakov AO, Furuyama T, Kobayashi N, Konev DV, Goncharova OA, Trashin SA, De Wael K, Sulimenkov IV, Filatov VV, Kozlovskiy VI, Tomilova LG, Stuzhin PA, Pushkarev VE, Dalton Transactions 50, 6245 (2021). http://doi.org/10.1039/D1DT00088H
Abstract: Reaction of (2,3,9,10,16,17,23,24-octabutylphthalocyaninato)lanthanide(iii) acetylacetonates ((Bu)PcLn(acac), 1a-c, Ln = Lu (a), Eu (b), La (c)) with a tetrakis(5,7-bis(4-tert-butylphenyl)-6H-1,4-diazepino)[2,3-b,g,l,q]porphyrazine ligand ((tBuPh)DzPzH(2), 2) produced sandwich compounds ((tBuPh)DzPz)Ln(Pc-Bu) (3a-c), which represent the first heteroleptic double-deckers incorporating both Pc and DzPz decks. A combination of high-resolution mass spectrometry, UV-Vis/NIR, MCD, and H-1 NMR spectroscopy, and square-wave voltammetry provided unambiguous characterization of target complexes 3 indicating that their spectral and electrochemical properties are generally intermediate with respect to their homoleptic relatives. Based on the data of solution-state H-1-H-1 NMR (COSY, NOESY) correlation spectroscopy supported by DFT calculations, a dimerization tendency of compounds 3 proportional to the Ln(iii) ion size was found. The spectroelectrochemical study of 3 and the corresponding homoleptic double-deckers revealed a pronounced tendency to aggregation of the one-electron oxidized forms of DzPz-containing double-decker complexes compared to homoleptic Pc(2)Ln compounds.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.029
DOI: 10.1039/D1DT00088H
|
|
|
“Polycyclodextrin and carbon nanotubes as composite for tyrosinase immobilization and its superior electrocatalytic activity towards butylparaben an endocrine disruptor”. Rather JA, Pilehvar S, De Wael K, Journal of nanoscience and nanotechnology 15, 3365 (2015). http://doi.org/10.1166/JNN.2015.10210
Abstract: We developed a protocol for the immobilization of tyrosinase (Tyr) on the composite of polycyclodextrin polymer (CDP) and carbon nanotubes for the detection of an endocrine disruptor, i.e., butylparaben (BP). The formation of the CDP polymer was characterized by UV-Vis spectrophotometry. The conducting film of cross-linked CDP and carbon nanotubes, displays excellent matrix capabilities for Tyr immobilization. The host-guest chemical reaction ability of CD and the ππ stacking interaction assure the bioactivity of Tyr towards butylparaben. The developed biosensor was characterized electrochemically by electrochemical impedance spectroscopy. The enzyme-substrate kinetic parameters such as the apparent Michaelis-Menten constant (K M app) was measured under saturated substrate concentration. The determination of butylparaben was carried out by using square wave voltammetry over the concentration range of 2.1 to 35.4 μM with a detection limit of 0.1 μM. The fabricated biosensor was successfully applied in real-life cosmetic samples with good recovery ranging from 98.5 to 102.8%.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 3
DOI: 10.1166/JNN.2015.10210
|
|
|
“Electrochemical determination of hydrogen peroxide with cytochrome c peroxidase and horse heart cytochrome c entrapped in a gelatin hydrogel”. De Wael K, Bashir Q, van Vlierberghe S, Dubruel P, Heering HA, Adriaens A, Bioelectrochemistry: an international journal devoted to electrochemical aspects of biology and biological aspects of electrochemistry 83, 15 (2012). http://doi.org/10.1016/J.BIOELECHEM.2011.07.001
Abstract: A novel and versatile method, based on a membrane-free enzyme electrode in which both the enzyme and a mediator protein are entrapped in a gelatine hydrogel was developed for the fabrication of biosensors. As a proof of principle, we prepared a hydrogen peroxide biosensor by successfully entrapping both horse heart cytochrome c (HHC) and Saccharomyces cerevisae cytochrome c peroxidase (CCP) in a gelatin matrix which is immobilized on a gold electrode. This electrode was first pretreated with 6-mercaptohexanol. The biosensor displayed a rapid response and an expanded linear response range from 0 to 0.3 mM (R = 0.987) with a detection limit of 1 × 10− 5 M in a HEPES buffer solution (pH 7.0). This method of encapsulation is now further investigated for industrial biosensor applications.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.346
Times cited: 31
DOI: 10.1016/J.BIOELECHEM.2011.07.001
|
|
|
“Covalent immobilization of delipidated human serum albumin on poly(pyrrole-2-carboxylic) acid film for the impedimetric detection of perfluorooctanoic acid”. Moro G, Bottari F, Liberi S, Covaceuszach S, Cassetta A, Angelini A, De Wael K, Moretto LM, Bioelectrochemistry 134, 107540 (2020). http://doi.org/10.1016/J.BIOELECHEM.2020.107540
Abstract: The immobilization of biomolecules at screen printed electrodes for biosensing applications is still an open challenge. To enrich the toolbox of bioelectrochemists, graphite screen printed electrodes (G-SPE) were modified with an electropolymerized film of pyrrole-2-carboxilic acid (Py-2-COOH), a pyrrole derivative rich in carboxylic acid functional groups. These functionalities are suitable for the covalent immobilization of biomolecular recognition layers. The electropolymerization was first optimized to obtain stable and conductive polymeric films, comparing two different electrolytes: sodium dodecyl sulphate (SDS) and sodium perchlorate. The G-SPE modified with Py-2-COOH in 0.1 M SDS solution showed the required properties and were further tested. A proof-of-concept study for the development of an impedimetric sensor for perfluorooctanoic acid (PFOA) was carried out using the delipidated human serum albumin (hSA) as bioreceptor. The data interpretation was supported by size exclusion chromatography and small-angle X-ray scattering (SEC-SAXS) analysis of the bioreceptor-target complex and the preliminary results suggest the possibility to further develop this biosensing strategy for toxicological and analytical studies.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 5
DOI: 10.1016/J.BIOELECHEM.2020.107540
|
|
|
“Development of an electrochemiluminescent oligonucleotide-based assay for the quantification of prostate cancer associated miR-141-3p in human serum”. Campos R, Thiruvottriyur Shanmugam S, Daems E, Ribeiro R, De Wael K, Bioelectrochemistry: an international journal devoted to electrochemical aspects of biology and biological aspects of electrochemistry 153, 108495 (2023). http://doi.org/10.1016/J.BIOELECHEM.2023.108495
Abstract: MicroRNAs (miRNAs) are small oligonucleotides (18–25 bases), biologically relevant for epigenetic regulation of key processes, particularly in association with cancer. Research effort has therefore been directed towards the monitoring and detection of miRNAs to progress (early) cancer diagnoses. Traditional detection strategies for miRNAs are expensive, with a lengthy time-to-result. In this study we develop an oligonucleotide-based assay using electrochemistry for the specific, selective and sensitive detection of a circulating miRNA (miR-141) associated with prostate cancer. In the assay, the excitation and readout of the signal are independent: an electrochemical stimulation followed by an optical readout. A ‘sandwich’ approach is incorporated, consisting of a biotinylated capture probe immobilised on streptavidin-functionalised surfaces and a detection probe labelled with digoxigenin. We show that the assay allows the detection of miR-141 in human serum, even in the presence of other miRNAs, with a LOD of 0.25 pM. The developed electrochemiluminescent assay has, therefore, the potential for efficient universal oligonucleotide target detection via the redesign of capture and detection probes.
Keywords: A1 Journal article; Engineering sciences. Technology; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 5
DOI: 10.1016/J.BIOELECHEM.2023.108495
|
|
|
“Haem-mediated albumin biosensing : towards voltammetric detection of PFOA”. Moro G, Campos R, Daems E, Moretto LM, De Wael K, Bioelectrochemistry: an international journal devoted to electrochemical aspects of biology and biological aspects of electrochemistry 152, 108428 (2023). http://doi.org/10.1016/J.BIOELECHEM.2023.108428
Abstract: The haem group is a promising redox probe for the design of albumin-based voltammetric sensors. Among the endogenous ligands carried by human serum albumin (hSA), haem is characterised by a reversible redox behaviour and its binding kinetics strongly depend on hSA’s conformation, which, in turn, depends on the presence of other ligands. In this work, the potential applicability of haem, especially hemin, as a redox probe was first tested in a proof-of-concept study using perfluorooctanoic acid (PFOA) as model analyte. PFOA is known to bind hSA by occupying Sudlow’s I site (FA7) which is spatially related to the haem-binding site (FA1). The latter undergoes a conformational change, which is expected to affect hemin’s binding kinetics. To verify this hypothesis, hemin:albumin complexes in the presence/absence of PFOA were first screened by UV–Vis spectroscopy. Once the complex formation was verified, haem was further characterised via electrochemical methods to estimate its electron transfer kinetics. The hemin:albumin:PFOA system was studied in solution, with the aim of describing the multiple equilibria at stake and designing an electrochemical assay for PFOA monitoring. This latter could be integrated with protein-based bioremediation approaches for the treatment of per- and polyfluoroalkyl substances polluted waters. Overall, our preliminary results show how hemin can be applied as a redox probe in albumin-based voltammetric sensing strategies.
Keywords: A1 Journal article; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 5
DOI: 10.1016/J.BIOELECHEM.2023.108428
|
|
|
“The organo-metal-like nature of long-range conduction in cable bacteria”. Pankratov D, Hidalgo Martinez S, Karman C, Gerzhik A, Gomila G, Trashin S, Boschker HTS, Geelhoed JS, Mayer D, De Wael K, Meysman FJR, Bioelectrochemistry: an international journal devoted to electrochemical aspects of biology and biological aspects of electrochemistry 157, 108675 (2024). http://doi.org/10.1016/J.BIOELECHEM.2024.108675
Abstract: Cable bacteria are filamentous, multicellular microorganisms that display an exceptional form of biological electron transport across centimeter-scale distances. Currents are guided through a network of nickel-containing protein fibers within the cell envelope. Still, the mechanism of long-range conduction remains unresolved. Here, we characterize the conductance of the fiber network under dry and wet, physiologically relevant, conditions. Our data reveal that the fiber conductivity is high (median value: 27 S cm−1; range: 2 to 564 S cm−1), does not show any redox signature, has a low thermal activation energy (Ea = 69 ± 23 meV), and is not affected by humidity or the presence of ions. These features set the nickel-based conduction mechanism in cable bacteria apart from other known forms of biological electron transport. As such, conduction resembles that of an organic semi-metal with a high charge carrier density. Our observation that biochemistry can synthesize an organo-metal-like structure opens the way for novel bio-based electronic technologies.
Keywords: A1 Journal article
Impact Factor: 5
DOI: 10.1016/J.BIOELECHEM.2024.108675
|
|
|
“Singlet oxygen-based photoelectrochemical detection of miRNAs in prostate cancer patients&rsquo, plasma : a novel diagnostic tool for liquid biopsy”. Thiruvottriyur Shanmugam S, Campos R, Trashin S, Daems E, Carneiro D, Fraga A, Ribeiro R, De Wael K, Bioelectrochemistry: an international journal devoted to electrochemical aspects of biology and biological aspects of electrochemistry 158, 108698 (2024). http://doi.org/10.1016/J.BIOELECHEM.2024.108698
Abstract: Dysregulation of miRNA expression occurs in many cancers, making miRNAs useful in cancer diagnosis and therapeutic guidance. In a clinical context using methods such as polymerase chain reaction (PCR), the limited amount of miRNAs in circulation often limits their quantification. Here, we present a PCR-free and sensitive singlet oxygen (1O2)-based strategy for the detection and quantification of miRNAs in untreated human plasma from patients diagnosed with prostate cancer. A target miRNA is specifically captured by functionalised magnetic beads and a detection oligonucleotide probe in a sandwich-like format. The formed complex is concentrated at the sensor surface via magnetic beads, providing an interface for the photoinduced redox signal amplification. The detection oligonucleotide probe bears a molecular photosensitiser, which produces 1O2 upon illumination, oxidising a redox reporter and creating a redox cycling loop, allowing quantification of pM level miRNA in diluted human plasma within minutes after hybridisation and without target amplification.
Keywords: A1 Journal article; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 5
DOI: 10.1016/J.BIOELECHEM.2024.108698
|
|
|
“Kinetic properties and heme pocket structure of two domains of the polymeric hemoglobin of Artemia in comparison with the native molecule”. Borhani AH, Berghmans H, Trashin S, De Wael K, Fago A, Moens L, Habibi-Rezaei M, Dewilde S, Biochimica et biophysica acta : proteins and proteomics 1854, 1307 (2015). http://doi.org/10.1016/J.BBAPAP.2015.05.007
Abstract: In this project, we studied some physicochemical properties of two different globin domains of the polymeric hemoglobin of the brine shrimp Artemia salina and compared them with those of the native molecule. Two domains (AsHbC1D1 and AsHbC1D5) were cloned and expressed in BL21(DE3)pLysS strain of Escherichiacoli. The recombinant proteins as well as the native hemoglobin (AfHb) were purified from bacteria and frozen Artemia, respectively by standard chromatographic methods and assessed by SDS-PAGE. The heme environment of these proteins was studied by optical spectroscopy and ligand-binding kinetics (e.g. CO association and O2 binding affinity) were measured for the two recombinant proteins and the native hemoglobin. This indicates that the CO association rate for AsHbC1D1 is higher than that of AsHbC1D5 and AfHb, while the calculated P50 value for AsHbC1D1 is lower than that of AsHbC1D5 and AfHb. The geminate and bimolecular rebinding parameters indicate a significant difference between both domains. Moreover, EPR results showed that the heme pocket in AfHb is in a more closed conformation than the heme pocket in myoglobin. Finally, the reduction potential of − 0.13 V versus the standard hydrogen electrode was determined for AfHb by direct electrochemical measurements. It is about 0.06 V higher than the potential of the single domain AsHbC1D5. This work shows that each domain in the hemoglobin of Artemia has different characteristics of ligand binding.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.773
DOI: 10.1016/J.BBAPAP.2015.05.007
|
|
|
“Water quality assessment in Pangani river basin, Tanzania : natural and anthropogenic influences on concentrations of nutrients and inorganic ions”. Hellar-Kihampa H, De Wael K, Lugwisha E, Van Grieken R, International journal of river basin management 11, 55 (2013). http://doi.org/10.1080/15715124.2012.759119
Abstract: The ongoing rapid expansions of human activities and population dynamics have potential impact on the environmental quality of the Pangani river basin, one of the largest water resources in Tanzania, including possible loadings of different kinds of micro-contaminants. However, specific extents of the impacts are rather not well investigated. In this work, we assessed the environmental quality of the basin, based on seasonal characterisation of physicochemical water and sediments parameters, dissolved inorganic ions and nutrient loads. The contributions of geochemical processes and land-use practices were evaluated by multivariate correlations and principal component analysis (PCA). Hierarchical cluster analysis was used to classify similar water quality stations and identify the most and least enriched ones. Surface waters were slightly alkaline, characterised by low total dissolved solids (48652 mg/L). Extremely low oxygen concentration (2.0 mg/L) was also a cause of concern at one station. The Na+ and HCO3 − ions provided the dominant cation and anion, respectively. PCA identified weathering of carbonate and Na+ bearing rocks, gypsum dissolution and atmospheric deposition of sea-salt as the major factors controlling the ionic composition, contributing more than 60% of the spatial variance. Concentration profiles of the chemical species showed a generally low level of anthropogenic inputs, except at a few locations where nitrate and nitrite were significantly enriched above the limits of safe exposure, with patterns indicating influences of farming and livestock keeping. A seasonal difference was observed, with lower ion concentrations during the rainy season, likely due to the dilution effect of increased water discharge. The study provides new insights into the environmental quality of the basin, and indicates the need for continuous monitoring and assessment of the chemical species in the area.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/15715124.2012.759119
|
|
|
“Electrodeposition of gold nanoparticles on boron doped diamond electrodes for the enhanced reduction of small organic molecules”. Bottari F, De Wael K, Journal of electroanalytical chemistry : an international journal devoted to all aspects of electrode kynetics, interfacial structure, properties of electrolytes, colloid and biological electrochemistry. 801, 521 (2017). http://doi.org/10.1016/J.JELECHEM.2017.07.053
Abstract: The performance of gold nanoparticles electrodeposited on boron doped diamond (BDD) electrodes was investigated in respect to the reduction of chloramphenicol (CAP), an antibiotic of the phenicols family. The chosen deposition protocol, three nucleation-growing pulses, shows a remarkable surface coverage, with an even distribution of average-sized gold particles (~ 50 nm), and it was proven capable of generating a three-fold increase in the CAP reduction current. A calibration plot for CAP detection was obtained in the micromolar range (535 μM) with good correlation coefficient (0.9959) and an improved sensitivity of 0.053 μA μM− 1 mm− 2 compared to the electrochemistry of CAP at a bare BDD electrode.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.012
Times cited: 4
DOI: 10.1016/J.JELECHEM.2017.07.053
|
|
|
“Electrochemical identification of hazardous phenols and their complex mixtures in real samples using unmodified screen-printed electrodes”. Barich H, Cánovas R, De Wael K, Journal of electroanalytical chemistry : an international journal devoted to all aspects of electrode kynetics, interfacial structure, properties of electrolytes, colloid and biological electrochemistry. 904, 115878 (2022). http://doi.org/10.1016/J.JELECHEM.2021.115878
Abstract: The electrochemical behavior of some of the most relevant endocrine-disrupting phenols using unmodified carbon screen-printed electrodes (SPEs) is described for the first time. Experiments were made to assess the electrochemical behavior of phenol (PHOH), pentachlorophenol (PCP), 4-tert octylphenol (OP) and bisphenol A (BPA) and their determination in the most favorable conditions, using voltammetric methods such as cyclic voltammetry (CV), linear sweep voltammetry (LSV) and square wave voltammetry (SWV) in Britton Robinson (BR) buffer. Further, the usefulness of the electrochemical approach was validated with real samples from a local river and was compared to commercial phenols test kit, which is commonly used for on-site screening in industrial streams and wastewaters. Finally, the approach was compared with a lab-bench standard method using real samples, i.e., high-performance liquid chromatography with a photodiode array detector (HPLC-DAD).
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 4.5
DOI: 10.1016/J.JELECHEM.2021.115878
|
|
|
“Voltammetric sensing using an array of modified SPCE coupled with machine learning strategies for the improved identification of opioids in presence of cutting agents”. Ortiz-Aguayo D, De Wael K, del Valle M, Journal Of Electroanalytical Chemistry 902, 115770 (2021). http://doi.org/10.1016/J.JELECHEM.2021.115770
Abstract: This work reports the use of modified screen-printed carbon electrodes (SPCEs) for the identification of three drugs of abuse and two habitual cutting agents, caffeine and paracetamol, combining voltammetric sensing and chemometrics. In order to achieve this goal, codeine, heroin and morphine were subjected to Square Wave Voltammetry (SWV) at pH 7, in order to elucidate their electrochemical fingerprints. The optimized SPCEs electrode array, which have a differentiated response for the three oxidizable compounds, was derived from Carbon, Prussian blue, Cobalt (II) phthalocyanine, Copper (II) oxide, Polypyrrole and Palladium nanoparticles ink-modified carbon electrodes. Finally, Principal Component Analysis (PCA) coupled with Silhouette parameter assessment was used to select the most suitable combination of sensors for identification of drugs of abuse in presence of cutting agents.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 3.012
DOI: 10.1016/J.JELECHEM.2021.115770
|
|
|
“Selecting optimal carbon inks for fabricating high-performance screen-printed electrodes for diverse electroanalytical applications”. Barich H, Voet O, Sleegers N, Schram J, Montiel FN, Beltran V, Nuyts G, De Wael K, Journal of electroanalytical chemistry : an international journal devoted to all aspects of electrode kynetics, interfacial structure, properties of electrolytes, colloid and biological electrochemistry. 971, 118585 (2024). http://doi.org/10.1016/J.JELECHEM.2024.118585
Abstract: Carbon-based screen-printed electrodes (SPEs) are extensively employed in electrochemistry due to their reproducibility, low-cost production, disposability and versatility. It is commonly accepted that batch to batch variations may occur due to variations in the ink formulation or the use of a different ink to print the electrodes. In this paper, three different commercial carbon-based inks (DuPont, Loctite and SunChemical) were used to manufacture SPEs, referred to respectively as Dup-SPE, Loc-SPE and Sun-SPE, using a semi-automated screen-printing technology. This study focuses on evaluating the quality, characteristics and electrochemical performance of the fabricated SPEs. Furthermore, the study aimed to investigate potential correlations between the ink composition and the nature of different target molecules, as well as their electroanalytical responses. Specifically, phenolic compounds and cocaine cutting agents are tested in alkaline conditions, while benzodiazepines and cephalosporine antibiotics are investigated in acidic media using square wave voltammetry (SWV). This aims to extract insights for the proper selection of inks and SPEs in both conditions. Additionally, a scan rate study of cephalosporine antibiotics using linear sweep voltammetry (LSV) is performed confirming the ion-exchange polymer layer on the electrode surface of Loc-SPE, which impact surface and electrochemical properties, leading to drawbacks in alkaline SWV sensing, but strategic benefits in reductive sensing resulting in an enhanced selective detection of specific targets. The insights on ink-specific influences on the surface and electrochemical properties of the SPEs obtained, may be useful for facilitating the electrode selection in diverse electrochemical applications, emphasizing the critical role of ink composition in achieving desired sensing capabilities.
Keywords: A1 Journal article; Engineering sciences. Technology; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab); Antwerp engineering, PhotoElectroChemistry & Sensing (A-PECS)
Impact Factor: 4.5
DOI: 10.1016/J.JELECHEM.2024.118585
|
|