|
“Comparison of four mobile, non‐invasive diagnostic techniques for differentiating glass types in historical leaded windows : MA‐XRF , UV–Vis–NIR, Raman spectroscopy and IRT”. Cagno S, van der Snickt G, Legrand S, Caen J, Patin M, Meulebroeck W, Dirkx Y, Hillen M, Steenackers G, Rousaki A, Vandenabeele P, Janssens K, X-Ray Spectrometry , xrs.3185 (2020). http://doi.org/10.1002/XRS.3185
Abstract: This paper critically compares the performance of four non-invasive techniques that match the accuracy, flexibility, time-efficiency, and transportability required for in situ characterization of leaded glass windows: macroscopic X-ray fluorescence imaging (MA-XRF), UV-Vis-NIR, Raman spectroscopy, and infrared thermography (IRT). In order to compare the techniques on equal grounds, all techniques were tested independently of each other by separate research groups on the same historical leaded window tentatively dated to the 17th century, without prior knowledge. The aim was to assess the ability of these techniques to document the conservation history of the window by classifying and grouping the colorless glass panes, based on differences in composition. IRT, MA-XRF and UV-Vis-NIR spectroscopy positively distinguished at least two glass groups, with MA-XRF providing the most detailed chemical information. In particular, based on the ratio between the network modifier (K) and network stabilizer (Ca) and on the level of colorants and decolorizers (Fe, Mn, As), the number of plausible glass families could be strongly reduced. In addition, UV-Vis-NIR detected cobalt at ppm level and gave more specific information on the chromophore Fe2+/Fe(3+)ratio. Raman spectroscopy was hampered by fluorescence caused by the metal ions of the decolorizer in most of the panes, but nevertheless identified one group as HLLA.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
Impact Factor: 1.2
DOI: 10.1002/XRS.3185
|
|
|
“Editorial: Award for best XRS referee during 2007-2008”. Van Grieken R, X-ray spectrometry 37, 571 (2008). http://doi.org/10.1002/XRS.1107
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1107
|
|
|
“Study of the uniformity of aerosol filters by scanning MA-XRF”. Cabal A, Legrand S, Van den Bril B, Tote K, Janssens K, van Espen P, X-ray spectrometry
T2 –, 17th European Conference on X-Ray Spectrometry (EXRS), JUN 19-24, 2016, Univ Gothenburg, Univ Gothenburg, Gothenburg, SWEDEN 46, 461 (2017). http://doi.org/10.1002/XRS.2767
Abstract: Energy-dispersive X-ray fluorescence (XRF) is an attractive analytical method to determine the level of air pollution by heavy metals. The concentration of the filter in ng/cm(2) is obtained by direct comparison of the net characteristic line intensity of an element with that of a thin film standard. As the sampled area on the filter and the area of the standard are larger than the area analysed by the instrument, the distribution of the elements on the surface of both samples and standards have to be sufficiently uniform. If this is not the case, biased concentration estimates are obtained. Two scanning macro-XRF setups with a beam diameter of similar to 0.5 mm were used to investigate the distribution of elements in (1) commercially available (Micromatter) standards, (2) in-house quartz filter standards obtained with an aerosol generator and (3) particulatematter (PM10) collected on quartz filters by a Leckel SEQ 47/50 sampler. The uniformity of the Micromatter standards was better than 2%. At least some in-house standards showed a concave distribution with less material at the edges. The maximum bias introduced by this is less than 5%. Because of the limited sensitivity of scanning XRF compared with conventional XRF, the distribution of only a few common elements like Ca and Fe could be determined reliably in aerosol filters. The distribution of some heavy elements could only be measured in filters sampled in polluted regions. In general, the loading of particulate matter over the filters was uniform. Copyright (C) 2017 John Wiley & Sons, Ltd.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 4
DOI: 10.1002/XRS.2767
|
|
|
“New insights in technology characterization of medieval Valencia glazes”. Romero-Pastor J, Garcia-Porras A, Van Grieken R, Potgieter-Vermaak S, Coll-Conesa J, Cardell C, X-ray spectrometry 44, 426 (2015). http://doi.org/10.1002/XRS.2613
Abstract: This study shows the first Raman microscopy (RM) and scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDX) characterization of two 14th and 15th century lead-glazed and luster ceramics from the Manises and Paterna workshops (Valencia, Spain) produced after the Aragon Christian conquest of the Iberian Peninsula (14th century). According to experts, these coetaneous ceramics were most probably involved in a process of technological transfer from the Islamic area of Southeast Spain to the Christian area of Valencia (East Spain) at the beginning of the 14th century; later on, the celebrated Manises and Paterna workshops were formed. Although these ceramics have been studied widely in terms of production technology (ceramic body, glazes and luster) using an array of diverse analytical techniques, until now, an RM study has not been carried out. This paper presents results regarding the complex chemical composition of the glaze and luster coloring agents, and the quality of color manufacturing processes, elucidating firing conditions via spectral components analysis (i.e., Q(n) for stretching/bending components) and polymerization index (Ip), emphasizing chronology and pigment technology changes between both Valencian workshops. Coloring agents identified in glazes and lusters were cobalt present in blue glazes, copper in greenish glazes, copper and cobalt in the turquoise glaze, and pyrolusite in black glazes. Tin oxyde was used as an opacifier in white glazes. Two luster manufacture recipes were recognized mainly based on copper and silver compounds. Calculated firing temperatures were up to 1000 degrees C for white glazes and up to 600 degrees C for luster and color glazes. Copyright (c) 2015 John Wiley & Sons, Ltd.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2613
|
|
|
“Evaluation of energy-dispersive x-ray spectra of low-Z elements from electron-probe microanalysis of individual particles”. Osán J, de Hoog J, van Espen P, Szalóki I, Ro C-U, Van Grieken R, X-ray spectrometry 30, 419 (2001). http://doi.org/10.1002/XRS.523
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.523
|
|
|
“M\alpha/L\alpha intensity ratios for Ta, W, Pt, Au, Pb and Bi for electron energies in the 11-40 keV range”. Trincavelli J, Montoro S, van Espen P, Van Grieken R, X-ray spectrometry 22, 372 (1993). http://doi.org/10.1002/XRS.1300220510
Abstract: Both energy- and wavelength-dispersive systems were used to obtain Malpha/Lalpha intensity ratios for Ta, W, Pt, Au, Pb and Bi at various overvoltages. A table of these ratios corrected for matrix absorption and detector efficiency is presented, in addition to an interpolatory function of Malpha/Lalpha generated ratios vs. overvoltage, for each element. In addition, three different ZAF correction models were used to predict both detected and generated ratios. Finally, experimental Mbeta/Malpha ratios measured at different overvoltages are presented for the six elements considered.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300220510
|
|
|
“Automated segmentation of μ-XRF image sets”. Vekemans B, Janssens K, Vincze L, Aerts A, Adams F, Hertogen J, X-ray spectrometry 26, 333 (1997)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
|
|
|
“Comprehensive microanalytical study of welding aerosols with x-ray and Raman based methods”. Worobiec A, Stefaniak EA, Kiro S, Oprya M, Bekshaev A, Spolnik Z, Potgieter-Vermaak SS, Ennan A, Van Grieken R, X-ray spectrometry 36, 328 (2007). http://doi.org/10.1002/XRS.979
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.979
|
|
|
“EPMA and µ-SRXRF analysis and TEM-based microstructure characterization of a set of Roman glass fragments”. Fredrickx P, de Ryck I, Janssens K, Schryvers D, Petit J-P, Döcking H, X-ray spectrometry 33, 326 (2004). http://doi.org/10.1002/xrs.734
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 13
DOI: 10.1002/xrs.734
|
|
|
“Individual particle characterization of Siberian aerosols by micro-PIXE and backscattering spectrometry”. van Malderen H, Hoornaert S, Injuk J, Przybylowicz WJ, Pineda CA, Prozesky VM, Van Grieken R, X-ray spectrometry 30, 320 (2001). http://doi.org/10.1002/XRS.505
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.505
|
|
|
“Investigation on porosity changes of Lecce stone due to conservation treatments by means of x-ray nano- and improved micro-computed tomography: preliminary results”. Bugani S, Camaiti M, Morselli L, Van de Casteele E, Janssens K, X-ray spectrometry 36, 316 (2007). http://doi.org/10.1002/XRS.976
Keywords: A1 Journal article; Vision lab; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 28
DOI: 10.1002/XRS.976
|
|
|
“2014 Award for best referee of X-Ray Spectrometry”. Van Grieken R, X-ray spectrometry 43, 311 (2014). http://doi.org/10.1002/XRS.2564
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2564
|
|
|
“Assessment of aerosol particles within the Rubens' House Museum in Antwerp, Belgium”. Godoi RHM, Potgieter-Vermaak S, Godoi AFL, Stranger M, Van Grieken R, X-ray spectrometry 37, 298 (2008). http://doi.org/10.1002/XRS.1049
Abstract: The majority of researchers, conservators and curators recognise that atmospheric pollution is one of the major threats to works of art. In principle, all atmospheric particles, when deposited onto art objects can be considered harmful because of their potential in causing deterioration. Moreover, under certain conditions, particulate matter can induce and intensify surface damage, particularly because of its potential to serve as centre for moisture condensation and adsorbent of gaseous pollutants. To investigate the potential harm that these particles can cause, comprehensive characterisation of the particulate matter is necessary. Particulate matter was collected at the Rubens' House Museum in Antwerp, Belgium, where a unique exhibit of the paintings and living quarters of Peter Paul Rubens (1577-1640) are seen. Size segregated aerosol samples were collected for analyses of bulk and single particle elemental and molecular compositions. They were analysed by electron probe micro-analysis, utilising facilities for low-Z element determination, and by energy-dispersive x-ray fluorescence, to investigate the elemental composition of individual particles and bulk samples, and by micro Raman spectrometry, to elucidate the molecular composition. Results are interpreted separately and as a whole with the specific aim of identifying compounds that could contribute to the chemical reactions taking place on the surfaces of artefacts and which could potentially cause degradation of the objects.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1049
|
|
|
“Interpreting technical evidence from spectral imaging of paintings by Edouard Manet in the Courtauld Gallery”. Amato SR, Burnstock A, Cross M, Janssens K, Rosi F, Cartechini L, Fontana R, Dal Fovo A, Paolantoni M, Grazia C, Romani A, Michelin A, Andraud C, Tournie A, Dik J, X-ray spectrometry
T2 –, MA-XRF Workshop on Developments and Applications of Macro-XRF in, Conservation, Art, and Archeology, SEP 24-25, 2017, Trieste, ITALY 48, 282 (2019). http://doi.org/10.1002/XRS.2828
Abstract: The paintings by edouard Manet in The Courtauld Gallery Dejeuner sur l'herbe (1863-68), Marguerite de Conflans en Toilette de Bal (1870-1880), Banks of the Seine at Argenteuil (1874), and A Bar at the Folies-Bergere (1882) were investigated for the first time using a range of non-invasive in situ analyses. The aims of the study were to investigate the painting techniques and materials used for this group of works and to critically evaluate the technical evidence derived from the integrated use of imaging techniques and portable spectroscopic methods in this context. The paintings were investigated by means of macro X-ray fluorescence (MA-XRF), reflection spectral imaging, portable UV-Vis-NIR spectroscopy, portable Raman spectroscopy, and reflection FTIR. MA-XRF and reflection spectral imaging allowed visualising elements in the compositions that were not visible using traditional methods of technical study. For example, MA-XRF analysis of Dejeuner sur l'herbe revealed elements of the development of the composition that provided new evidence to consider its relationship to other versions of the composition. The study also highlighted questions about the interpretation of elemental distribution maps and spectral images that did not correspond to the reworking visible in X-radiographs. For example, in A Bar at the Folies-Bergere Manet made numerous changes during painting, which were not clearly visualised with any of the techniques used. The research has wider implications for the study of Impressionist paintings, as the results will support technical studies of works by other artists of the period who used similar materials and painting methods.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
DOI: 10.1002/XRS.2828
|
|
|
“Application of auxiliary signals in X-ray fluorescence and electron microprobe analysis for density evaluation”. Kuczumov A, Vekemans B, Schalm O, Vincze L, Dorriné, W, Gysels K, Van Grieken R, X-ray spectrometry 28, 282 (1999). http://doi.org/10.1002/(SICI)1097-4539(199907/08)28:4<282::AID-XRS352>3.0.CO;2-H
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/(SICI)1097-4539(199907/08)28:4<282::AID-XRS352>3.0.CO;2-H
|
|
|
“Analysis of X-ray spectra by iterative least squares (AXIL): new developments”. Vekemans B, Janssens K, Vincze L, Adams F, van Espen P, X-ray spectrometry 23, 278 (1994). http://doi.org/10.1002/XRS.1300230609
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300230609
|
|
|
“EXRS2022 : the 2022 edition of the European X-ray Spectrometry conference, held in Bruges, Belgium”. Janssens K, X-ray spectrometry 52, 276 (2023). http://doi.org/10.1002/XRS.3386
Keywords: Editorial; Antwerp X-ray Imaging and Spectroscopy (AXIS)
Impact Factor: 1.2
DOI: 10.1002/XRS.3386
|
|
|
“Current trends in the literature on X-ray emission spectrometry”. Van Grieken R, Markowicz A, Veny P, X-ray spectrometry 20, 271 (1991). http://doi.org/10.1002/XRS.1300200605
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300200605
|
|
|
“Theoretical evaluation of the effective alpha and De Jongh approaches in X-ray fluorescence analysis of geological materials in borax glass beads”. Muia LM, Van Grieken R, X-ray spectrometry 18, 259 (1989). http://doi.org/10.1002/XRS.1300180604
Abstract: An evaluation of the accuracy and suitability of the LachanceTraill algorithm using effective α-coefficients, and the De Jongh α approach for x-ray fluorescence analysis of borax glass beads prepared from geological material was performed. By using theoretical α-coefficients obtained from the same standard and calculated elemental intensities, the two algorithms were compared under identical conditions. When only the monitor standard is used, the LachanceTrail1 approach is found to be inferior to the De Jongh basic α method. If multi-standard calibration is performed for both approaches, the accuracies are almost identical and no significant difference is found in the results. The LachanceTraill algorithm has the advantage of being easier to implement on a minicomputer and, when used without standards, it is found to give results within a few percent of the true values, which is a useful indicator in the choice of appropriate standards for more accurate analytical work.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300180604
|
|
|
“Semi-quantitative analysis of the formation of a calcium oxalate protective layer for monumental limestone using combined micro-XRF and micro-XRPD”. Vanmeert F, Mudronja D, Fazinic S, Janssens K, Tibljas D, X-ray spectrometry 42, 256 (2013). http://doi.org/10.1002/XRS.2486
Abstract: A current method for the protection of cretaceous limestone present in various monuments consists of performing a passivating treatment with ammonium oxalate (AmOx). A calcium oxalate protective layer is formed on the surface and enhances the acid resistance of the stone. The in-depth formation of the calcium oxalate layer was investigated on cross sections by using combined micro X-ray fluorescence and micro X-ray powder diffraction (mu XRF/mu XRPD). XRPD showed the presence of both whewellite and weddellite in the calcite stone matrix. A correction was made for sample misalignment, which was visible in both the fluorescence and the diffraction line measurements. A semi-quantitative analysis was performed on the basis of Klug's equation for a two-phase mixture (the presence of weddellite was neglected) without the need for a known reference sample. By assuming two extreme compositions for a reference weight fraction (1 and 99wt%), it was possible to obtain whewellite concentration profiles, which can be used for comparing the effectiveness of different methods for the application of AmOx to the stone surface and the effect of treatment time and AmOx concentration used. It is shown that for the relative amounts of whewellite formed, the differences due to the assumed weight fractions are smaller than the errors due to sample heterogeneity and preferred orientation. Copyright (c) 2013 John Wiley & Sons, Ltd.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 5
DOI: 10.1002/XRS.2486
|
|
|
“Preface to the special issue on: MA-XRF “developments and applications of macro-XRF in conservation, art, and archeology&rdquo, (Trieste, Italy, 24 and 25 September 2017)”. Romano FP, Janssens K, X-ray spectrometry 48, 249 (2019). http://doi.org/10.1002/XRS.3047
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
DOI: 10.1002/XRS.3047
|
|
|
“Reconstruction of the three-dimensional distribution of elements in fly-ash particles by micro-XRF spectroscopy”. Rindby A, Janssens K, Osán J, X-ray spectrometry 32, 248 (2003). http://doi.org/10.1002/XRS.647
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 8
DOI: 10.1002/XRS.647
|
|
|
“Ruthenium staining as an alternative preparation method for automated EPMA of individual biogenic and organic particles”. Worobiec A, Kaplinski A, Van Grieken R, X-ray spectrometry 34, 245 (2005). http://doi.org/10.1002/XRS.807
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.807
|
|
|
“ID18F: a new micro-X-ray fluorescence end-station at the European Synchrotron Radiation Facility (ESRF): preliminary results”. Somogyi A, Drakopoulos M, Vincze L, Vekemans B, Camerani C, Janssens K, Snigirev A, Adams F, X-ray spectrometry 30, 242 (2001). http://doi.org/10.1002/XRS.494.ABS
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 76
DOI: 10.1002/XRS.494.ABS
|
|
|
“Monte Carlo simulation of conventional and synchrotron energy-dispersive X-ray spectrometers”. Janssens K, Vincze L, van Espen P, Adams F, X-ray spectrometry 22, 234 (1993). http://doi.org/10.1002/XRS.1300220412
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300220412
|
|
|
“Investigation of heavy metal distributions along 15m soil profiles using EDXRF, XRD, SEM-EDX, and ICP-MS techniques”. Ozen SA, Ozkalayci F, Cevik U, Van Grieken R, X-ray spectrometry 47, 231 (2018). http://doi.org/10.1002/XRS.2832
Abstract: The research of soil contamination by heavy metal is an important field due to its environmental and health implications. The goal was to study the elemental mobility as a function of depth. For this reason, the distribution of heavy metals (V, Cr, Co, Ni, Cu, Zn, As, Sn, and Pb) was investigated along soil profiles up to a depth of 15m at 9 sampling sites in the Nilufer industrial district (Bursa, Turkey). Elemental analyses were done with the Epsilon 5 energy dispersive X-ray fluorescence and inductively coupled plasma mass spectrometry equipment. Particle analysis was performed with a JEOL scanning electron microscope equipped with a Si(Li) X-ray detector. The crystallographic compositions of oxide compounds in soil samples were identified by a Rigaku X-ray diffraction instrument. Different parameters such as the soil's chemical (mineralogical structure, pH, and electrical conductivity) and physical properties (the number of blows, the stiffness index, the liquidity index, the plasticity index, and the water content) were analyzed. To assess the mobility of the heavy metals, diffusion (D) and convection coefficients (?) were calculated with the finite difference method. Convection was determined to dominate the studied region. In addition, the mobility coefficient was determined for each metal. High mobilities were determined for Zn and V, moderate mobilities for Cr, Ni, Cu, and As, and low mobilities were determined for Co and Pb. The results revealed that elements had reached depths of up to 15m, causing irreversible soil contamination that may lead to environmental health issues.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2832
|
|
|
“Monte Carlo simulation of backscattered peaks in secondary target energy-dispersive X-ray spectra”. Van Dyck P, Török S, Van Grieken R, X-ray spectrometry 15, 231 (1986). http://doi.org/10.1002/XRS.1300150403
Abstract: A Monte Carlo simulation has been developed to describe the incoherent and coherent scatter processes for the complex geometry of a secondary target energy-dispersive x-ray fluorescence system. Photons are followed from the x-ray tube anode until the detection of scattered secondary target photons in the active Si layer of the detector. The program quantitatively shows the broadening of the incoherent scatter peak with increasing atomic number, and it models the incoherent peak shape adequately. The incoherent-to-coherent scatter intensity ratios obtained differ by 1030% from the theoretical values, while their dependence on the sample atomic number corresponds to that expected from theory.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150403
|
|
|
“Optimized energy dispersive X-ray fluorescence analysis of atmospheric aerosols collected at pristine and perturbed Amazon Basin sites”. Arana A, Loureiro AL, Barbosa HMJ, Van Grieken R, Artaxo P, X-ray spectrometry 43, 228 (2014). http://doi.org/10.1002/XRS.2544
Abstract: Elemental composition of aerosols is important to source apportionment studies and to understand atmospheric processes that influence aerosol composition. Energy dispersive X-ray fluorescence spectroscopy was applied for measuring the elemental composition of Amazonian atmospheric aerosols. The instrument used was a spectrometer Epsilon 5, PANalytical B. V., with tridimensional geometry that reduces the background signal with a polarized X-ray detection. The measurement conditions were optimized for low-Z elements, e. g. Mg, Al, Si, that are present at very low concentrations in the Amazon. From Na to K, our detection limits are about 50% to 75% lower than previously published results for similar instrument. Calibration was performed using Micromatter standards, except for P whose standard was produced by nebulization of an aqueous solution of KH2PO4 at our laboratory. The multi-element reference material National Institute of Standards and Technology-2783 (air particulate filter) was used for evaluating the accuracy of the calibration procedure of the 22 elements in our standard analysis routine, and the uncertainty associated with calibration procedures was evaluated. The overall performance of the instrument and validation of our measurements were assessed by comparison with results obtained from parallel analysis using particle-induced X-ray emission and another Epsilon 5 spectrometer. The elemental composition in 660 samples collected at a pristine site in the Amazon Basin and of 1416 samples collected at a site perturbed by land use change was determined. Our measurements show trace elements associated with biogenic aerosols, soil dust, biomass burning, and sea-salt, even for the very low concentrations as observed in Amazonia. Copyright (C) 2014 John Wiley & Sons, Ltd.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2544
|
|
|
“Speciation of selected metals in aerosol samples by TXRF after sequential leaching”. Samek L, Ostachowicz B, Worobiec A, Spolnik Z, Van Grieken R, X-ray spectrometry 35, 226 (2006). http://doi.org/10.1002/XRS.905
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.905
|
|
|
“Progress in laboratory grazing emission X-ray fluorescence spectrometry”. Claes M, de Bokx P, Van Grieken R, X-ray spectrometry 28, 224 (1999). http://doi.org/10.1002/(SICI)1097-4539(199907/08)28:4<224::AID-XRS337>3.3.CO;2-W
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/(SICI)1097-4539(199907/08)28:4<224::AID-XRS337>3.3.CO;2-W
|
|