“Fluid modeling of the conversion of methane into higher hydrocarbons in an atmospheric pressure dielectric barrier discharge”. De Bie C, Verheyde B, Martens T, van Dijk J, Paulussen S, Bogaerts A, Plasma processes and polymers 8, 1033 (2011). http://doi.org/10.1002/ppap.201100027
Abstract: A one-dimensional fluid model for a dielectric barrier discharge in methane, used as a chemical reactor for gas conversion, is developed. The model describes the gas phase chemistry governing the conversion process of methane to higher hydrocarbons. The spatially averaged densities of the various plasma species as a function of time are discussed. Besides, the conversion of methane and the yields of the reaction products as a function of the residence time in the reactor are shown and compared with experimental data. Higher hydrocarbons (C2Hy and C3Hy) and hydrogen gas are typically found to be important reaction products. Furthermore, the main underlying reaction pathways are determined.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.846
Times cited: 70
DOI: 10.1002/ppap.201100027
|
|
|
“Fluid modelling of an atmospheric pressure dielectric barrier discharge in cylindrical geometry”. Petrović, D, Martens T, van Dijk J, Brok WJM, Bogaerts A, Journal of physics: D: applied physics 42, 205206 (2009). http://doi.org/10.1088/0022-3727/42/20/205206
Abstract: A numerical parameter study has been performed for a cylindrical atmospheric pressure dielectric barrier discharge (DBD) in helium with nitrogen impurities using a two-dimensional time-dependent fluid model. The calculated electric currents and gap voltages as a function of time for a given applied potential are presented, as well as the number densities of the various plasma species. This study shows that for the geometry under consideration the applied voltage parameters have a large impact on the electric current profiles and that the discharge current is always determined by the electron and ion conduction currents while the displacement current is nearly negligible. A relative broadening of the current profiles (compared with the duration of the half cycle of the applied voltage) with an increase in the applied frequency is obtained. Nearly sinusoidal current wave forms, usually typical for radio frequency DBDs, are observed while still operating at the frequencies of tens of kilohertz. For the setup under investigation, the Townsend mode of the DBD is observed in the entire range of applied voltage amplitudes and frequencies. It is shown that the average power density dissipated in the discharge increases with rising applied voltage and frequency. An increase in applied voltage frequency leads to an increase in the electron density and a decrease in electron energy, while increasing the voltage amplitude has the opposite effect.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.588
Times cited: 29
DOI: 10.1088/0022-3727/42/20/205206
|
|
|
“Fluid simulation of the bias effect in inductive/capacitive discharges”. Zhang Y-R, Gao F, Li X-C, Bogaerts A, Wang Y-N, Journal of vacuum science and technology: A: vacuum surfaces and films 33, 061303 (2015). http://doi.org/10.1116/1.4928033
Abstract: Computer simulations are performed for an argon inductively coupled plasma (ICP) with a capacitive radio-frequency bias power, to investigate the bias effect on the discharge mode transition and on the plasma characteristics at various ICP currents, bias voltages, and bias frequencies. When the bias frequency is fixed at 13.56 MHz and the ICP current is low, e.g., 6A, the spatiotemporal averaged plasma density increases monotonically with bias voltage, and the bias effect is already prominent at a bias voltage of 90 V. The maximum of the ionization rate moves toward the bottom electrode, which indicates clearly the discharge mode transition in inductive/capacitive discharges. At higher ICP currents, i.e., 11 and 13 A, the plasma density decreases first and then increases with bias voltage, due to the competing mechanisms between the ion acceleration power dissipation and the capacitive power deposition. At 11 A, the bias effect is still important, but it is noticeable only at higher bias voltages. At 13 A, the ionization rate is characterized by a maximum at the reactor center near the dielectric window at all selected bias voltages, which indicates that the ICP power, instead of the bias power, plays a dominant role under this condition, and no mode transition is observed. Indeed, the ratio of the bias power to the total power is lower than 0.4 over a wide range of bias voltages, i.e., 0300V. Besides the effect of ICP current, also the effect of various bias frequencies is investigated. It is found that the modulation of the bias power to the spatiotemporal distributions of the ionization rate at 2MHz is strikingly different from the behavior observed at higher bias frequencies. Furthermore, the minimum of the plasma density appears at different bias voltages, i.e., 120V at 2MHz and 90V at 27.12 MHz.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.374
Times cited: 9
DOI: 10.1116/1.4928033
|
|
|
“Fluid simulation of the phase-shift effect in hydrogen capacitively coupled plasmas: 1 : transient behaviour of electrodynamics and power deposition”. Zhang Y-R, Xu X, Bogaerts A, Wang Y-N, Journal of physics: D: applied physics 45, 015202 (2012). http://doi.org/10.1088/0022-3727/45/1/015202
Abstract: A two-dimensional self-consistent fluid model coupled with the full set of Maxwell equations is established to investigate the phase-shift effect on the transient behaviour of electrodynamics and power deposition in a hydrogen capacitively coupled plasma. The effect has been examined at 13.56 MHz and 100 MHz, respectively, because of the different phase-shift modulation when the electromagnetic effects are dominant. The results indicate that the spatiotemporal distributions of the plasma characteristics obtained for various phase-shift cases are obviously different both in shape and especially in absolute values. Indeed, when the phase difference varies from 0 to π, there is an increase in the electron flux, thus the power deposition becomes more pronounced. At the frequency of 13.56 MHz, the axial electron flux in the bulk plasma becomes uniform along the z-axis, and the radial electron flux exhibits two peaks within one period at the reverse-phase case, whereas the oscillation is less pronounced at the in-phase case. Furthermore, in the very high frequency discharge, the radial electron flux is alternately positive and negative with four peaks during one period, and the ionization mainly occurs in the sheath region, due to the prominent power deposition there at a phase difference equal to π.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.588
Times cited: 57
DOI: 10.1088/0022-3727/45/1/015202
|
|
|
“Fluid simulation of the phase-shift effect in hydrogen capacitively coupled plasmas: 2 : radial uniformity of the plasma characteristics”. Zhang Y-R, Xu X, Bogaerts A, Wang Y-N, Journal of physics: D: applied physics 45, 015203 (2012). http://doi.org/10.1088/0022-3727/45/1/015203
Abstract: A two-dimensional fluid model, including the full set of Maxwell equations, has been developed and applied to investigate the effect of a phase shift between two power sources on the radial uniformity of several plasma characteristics in a hydrogen capacitively coupled plasma. This study was carried out at various frequencies in the range 13.56200 MHz. When the frequency is low, at 13.56 MHz, the plasma density is characterized by an off-axis peak when both power sources are in-phase (phgr = 0), and the best radial uniformity is obtained at phgr = π. This trend can be explained because the radial nonuniformity caused by the electrostatic edge effect can be effectively suppressed by the phase-shift effect at a phase difference equal to π. When the frequency rises to 60 MHz, the plasma density profiles shift smoothly from edge-peaked over uniform to centre-peaked as the phase difference increases, due to the pronounced standing-wave effect, and the best radial uniformity is reached at phgr = 0.3π. At a frequency of 100 MHz, a similar behaviour is observed, except that the maximum of the plasma density moves again towards the radial edge at the reverse-phase case (phgr = π), because of the dominant skin effect. When the frequency is 200 MHz, the bulk plasma density increases significantly with increasing phase-shift values, and a better uniformity is obtained at phgr = 0.4π. This is because the density in the centre increases faster than at the radial edge as the phase difference rises, due to the increasing power deposition Pz in the centre and the decreasing power density Pr at the radial edge. As the phase difference increases to π, the maximum near the radial edge becomes obvious again. This is because the skin effect has a predominant influence on the plasma density under this condition, resulting in a high density at the radial edge. Moreover, the axial ion flux increases monotonically with phase difference, and exhibits similar profiles to the plasma density. The calculation results illustrate that the radial uniformity of the various plasma characteristics is strongly dependent on the applied frequency and the phase shift between both power sources, which is important to realize, for controlling the uniformity of the plasma etch and deposition processes.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.588
Times cited: 15
DOI: 10.1088/0022-3727/45/1/015203
|
|
|
“Fluid simulation of the phase-shift effect in Ar/CF4 capacitively coupled plasmas”. Zhang Y-R, Bogaerts A, Wang Y-N, Journal of physics: D: applied physics 45, 485204 (2012). http://doi.org/10.1088/0022-3727/45/48/485204
Abstract: A two-dimensional self-consistent fluid model combined with the full set of Maxwell equations is employed to investigate an Ar/CF4 capacitively coupled plasma, focusing on the phase-shift effect on the plasma characteristics at various frequencies and gas mixture ratios. When the discharge is sustained by a single frequency at 13.56 MHz in an Ar/CF4 mixture with a ratio of 0.9/0.1, no obvious difference is detected between the electron densities obtained in the so-called electrostatic model (with only the static electric fields taken into account) and the electromagnetic model (which includes the electromagnetic effects). However, as the frequency increases to 60 and 100 MHz, the difference becomes distinct, due to the significant influence of the electromagnetic effects. The phase-shift effect on the plasma radial uniformity has also been investigated in a dual frequency discharge, i.e. when the top driven source is switched on with a phase difference phiv ranging from 0 to π, in the frequency range 13.56100 MHz. At low concentration of CF4 (10%), Ar+ ions are the major positive ions in the entire range of frequencies. When the frequency is low, i.e. 13.56 MHz, the Ar+ density exhibits an off-axis peak at phiv = 0 due to the edge effect, and a better uniformity caused by the phase-shift modulation is obtained at phiv = π. At 60 MHz, the Ar+ density varies from edge-peaked at phiv = 0 to uniform (i.e. at phiv = 0.53π), and finally at phiv = π, a broad maximum is observed at the centre due to the standing-wave effect. As the frequency increases to 100 MHz, the best radial uniformity is reached at 0.25π, and the maximum moves again towards the radial wall in the reverse-phase case (phiv = π) due to the dominant skin effect. When the frequency is fixed at 100 MHz, the phase-shift control shows a different behaviour at a high concentration of CF4. For instance, the ${\rm CF}_3
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.588
Times cited: 8
DOI: 10.1088/0022-3727/45/48/485204
|
|
|
“Fluid simulations of frequency effects on nonlinear harmonics in inductively coupled plasma”. Si X-J, Zhao S-X, Xu X, Bogaerts A, Wang Y-N, Physics of plasmas 18, 033504 (2011). http://doi.org/10.1063/1.3566007
Abstract: A fluid model is self-consistently established to investigate the harmonic effects in an inductively coupled plasma, where the electromagnetic field is solved by the finite difference time domain technique. The spatiotemporal distribution of harmonic current density, harmonic potential, and other plasma quantities, such as radio frequency power deposition, plasma density, and electron temperature, have been investigated. Distinct differences in current density have been observed when calculated with and without Lorentz force, which indicates that the nonlinear Lorentz force plays an important role in the harmonic effects, especially at low frequencies. Moreover, the even harmonics are larger than the odd harmonics both in the current density and the potential. Finally, the dependence of various plasma quantities with and without the Lorentz force on various driving frequencies is also examined. It is shown that the deposited power density decreases and the depth of penetration increases slightly because of the Lorentz force. The electron density increases distinctly while the electron temperature remains almost the same when the Lorentz force is taken into account.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.115
Times cited: 7
DOI: 10.1063/1.3566007
|
|
|
“Fluorinesilicon surface reactions during cryogenic and near room temperature etching”. Tinck S, Neyts EC, Bogaerts A, The journal of physical chemistry: C : nanomaterials and interfaces 118, 30315 (2014). http://doi.org/10.1021/jp5108872
Abstract: Cyrogenic etching of silicon is envisaged to enable better control over plasma processing in the microelectronics industry, albeit little is known about the fundamental differences compared to the room temperature process. We here present molecular dynamics simulations carried out to obtain sticking probabilities, thermal desorption rates, surface diffusion speeds, and sputter yields of F, F2, Si, SiF, SiF2, SiF3, SiF4, and the corresponding ions on Si(100) and on SiF13 surfaces, both at cryogenic and near room temperature. The different surface behavior during conventional etching and cryoetching is discussed. F2 is found to be relatively reactive compared to other species like SiF03. Thermal desorption occurs at a significantly lower rate under cryogenic conditions, which results in an accumulation of physisorbed species. Moreover, ion incorporation is often observed for ions with energies of 30400 eV, which results in a relatively low net sputter yield. The obtained results suggest that the actual etching of Si, under both cryogenic and near room temperature conditions, is based on the complete conversion of the Si surface to physisorbed SiF4, followed by subsequent sputtering of these molecules, instead of direct sputtering of the SiF03 surface.
Keywords: A1 Journal article; Engineering sciences. Technology; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.536
Times cited: 11
DOI: 10.1021/jp5108872
|
|
|
“Formation of a nanoscale SiO2 capping layer on photoresist lines with an Ar/SiCl4/O2 inductively coupled plasma : a modeling investigation”. Tinck S, Altamirano-Sánchez E, De Schepper P, Bogaerts A, Plasma processes and polymers 11, 52 (2014). http://doi.org/10.1002/ppap.201300062
Abstract: PECVD of a nanoscale SiO2 capping layer using low pressure SiCl4/O-2/Ar plasmas is numerically investigated. The purpose of this capping layer is to restore photoresist profiles with improved line edge roughness. A 2D plasma and Monte Carlo feature profile model are applied for this purpose. The deposited films are calculated for various operating conditions to obtain a layer with desired shape. An increase in pressure results in more isotropic deposition with a higher deposition rate, while a higher power creates a more anisotropic process. Dilution of the gas mixture with Ar does not result in an identical capping layer shape with a thickness linearly correlated to the dilution. Finally, a substrate bias seems to allow proper control of the vertical deposition rate versus sidewall deposition as desired.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.846
Times cited: 1
DOI: 10.1002/ppap.201300062
|
|
|
“Formation of endohedral Ni@C60 and exohedral NiC60 metallofullerene complexes by simulated ion implantation”. Neyts EC, Bogaerts A, Carbon 47, 1028 (2009). http://doi.org/10.1016/j.carbon.2008.12.023
Abstract: The interaction of thermal and hyperthermal Ni ions with gas-phase C60 fullerene was investigated at two temperatures with classical molecular dynamics simulations using a recently developed interatomic many-body potential. The interaction between Ni and C60 is characterized in terms of the NiC60 binding sites, complex formation, and the collision and temperature induced deformation of the C60 cage structure. The simulations show how ion implantation theoretically allows the synthesis of both endohedral Ni@C60 and exohedral NiC60 metallofullerene complexes.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.337
Times cited: 15
DOI: 10.1016/j.carbon.2008.12.023
|
|
|
“Formation of single layer graphene on nickel under far-from-equilibrium high flux conditions”. Neyts EC, van Duin ACT, Bogaerts A, Nanoscale 5, 7250 (2013). http://doi.org/10.1039/c3nr00153a
Abstract: We investigate the theoretical possibility of single layer graphene formation on a nickel surface at different substrate temperatures under far-from-equilibrium high precursor flux conditions, employing state-of-the-art hybrid reactive molecular dynamics/uniform acceptance force bias Monte Carlo simulations. It is predicted that under these conditions, the formation of a single layer graphene-like film may proceed through a combined depositionsegregation mechanism on a nickel substrate, rather than by pure surface segregation as is typically observed for metals with high carbon solubility. At 900 K and above, nearly continuous graphene layers are obtained. These simulations suggest that single layer graphene deposition is theoretically possible on Ni under high flux conditions.
Keywords: A1 Journal article; Engineering sciences. Technology; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 7.367
Times cited: 25
DOI: 10.1039/c3nr00153a
|
|
|
“A Fourier transform laser microprobe mass spectrometer with external ion source for organic and inorganic surface and micro-analysis”. van Roy W, Struyf H, van Vaeck L, Gijbels R, Caravatti P Wiley, Chichester, page 463 (1994).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“From anisole to 1,2,4,5-tetramethoxybenzene: theoretical study of the factors that determine the conformation of methoxy groups on a benzene ring”. Vande Velde C, Bultinck E, Tersago K, van Alsenoy C, Blockhuys F, International journal of quantum chemistry 107, 670 (2007). http://doi.org/10.1002/qua.21183
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.92
Times cited: 14
DOI: 10.1002/qua.21183
|
|
|
“Functioning of thiocyanate ions during sulphur and sulphur-plus-gold Sensitization”. Charlier E, Gijbels R, Van Doorselaer M, De Keyzer R, , 172 (2000)
Abstract: Not much about the effect of thiocyanate addition on the sulphur ripening is known, although it is used for many applications in photographic practice. Via a combination of tracer analysis and diffuse reflectance spectroscopy the effect of thiocyanate addition on the sulphur and sulphur-plus-gold ripening could be unveiled. When thiocyanate is added prior to the sulphur addition, it appears to rearrange the silver halide surface in such way that the sulphur deposition rate is enhanced, but the supply of interstitials is limited. Addition of thiocyanate after the sulphur reaction results in the formation of thiocyanate complexes with silver, from which a silver ion is more easily deposited in a surface cell of the silver sulphide clusters thus enhancing the sensitization rate. For sulphur-plus-gold sensitized emulsions it was observed that part of the gold ions could be removed out of the Ag2-xAuxS clusters by addition of thiocyanate ions and subsequent washing. Hence, it was concluded that two different types of gold ions are present in the silver sulphide clusters; 1. gold ions which are substitutional for silver (bound between sulphur and bromide ions) 2. gold ions which bridge two or three sulphur atoms. Incorporation of gold ions into silver sulphide clusters suppresses their optical absorption in diffuse reflectance spectroscopy. Since the optical absorption at 505 nm can completely be restored by addition of thiocyanate, it is assumed that the entity absorbing at this wavelength is a monomer of silver sulphide.
Keywords: P1 Proceeding; Engineering sciences. Technology; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Fundamental aspects and applications of glow discharge spectrometric techniques”. Bogaerts A, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 53, 1 (1998). http://doi.org/10.1016/S0584-8547(97)00122-5
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 49
DOI: 10.1016/S0584-8547(97)00122-5
|
|
|
“Fundamental aspects of an analytical glow discharge”. van Straaten M, Gijbels R Royal Society of Chemistry, Cambridge, page 130 (1993).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Fundamental studies on a planar-cathode direct current glow discharge: part 1: characterization via laser scattering techniques”. Gamez G, Bogaerts A, Andrade F, Hieftje GM, Spectrochimica acta: part B : atomic spectroscopy 59, 435 (2004). http://doi.org/10.1016/j.sab.2003.12.002
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 24
DOI: 10.1016/j.sab.2003.12.002
|
|
|
“Fundamental studies on a planar-cathode direct current glow discharge: part 2: numerical modeling and comparison with laser scattering experiments”. Bogaerts A, Gijbels R, Gamez G, Hieftje GM, Spectrochimica acta: part B : atomic spectroscopy 59, 449 (2004). http://doi.org/10.1016/j.sab.2003.12.001
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 26
DOI: 10.1016/j.sab.2003.12.001
|
|
|
“Gas discharge plasmas and their applications”. Bogaerts A, Neyts E, Gijbels R, van der Mullen J, Spectrochimica acta: part B : atomic spectroscopy 57, 609 (2002). http://doi.org/10.1016/S0584-8547(01)00406-2
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 462
DOI: 10.1016/S0584-8547(01)00406-2
|
|
|
“Gas purification by nonthermal plasma : a case study of ethylene”. Aerts R, Tu X, Van Gaens W, Whitehead JC, Bogaerts A, Environmental science and technology 47, 6478 (2013). http://doi.org/10.1021/es400405c
Abstract: The destruction of ethylene in a dielectric barrier discharge plasma is investigated by the combination of kinetic modeling and experiments, as a case study for plasma-based gas purification. The influence of the specific energy deposition on the removal efficiency and the selectivity toward CO and CO2 is studied for different concentrations of ethylene. The model allows the identication of the destruction pathway in dry and humid air. The latter is found to be mainly initiated by metastable N2 molecules, but the further destruction steps are dominated by O atoms and OH radicals. Upon increasing air humidity, the removal efficiency drops by ±15% (from 85% to 70%), but the selectivity toward CO and CO2 stays more or less constant at 60% and 22%, respectively. Beside CO and CO2, we also identified acetylene, formaldehyde, and water as byproducts of the destruction process, with concentrations of 1606 ppm, 15033 ppm, and 185 ppm in humid air (with 20% RH), respectively. Finally, we investigated the byproducts generated by the humid air discharge itself, which are the greenhouse gases O3, N2O, and the toxic gas NO2.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.198
Times cited: 56
DOI: 10.1021/es400405c
|
|
|
“Gas ratio effects on the Si etch rate and profile uniformity in an inductively coupled Ar/CF4 plasma”. Zhao S-X, Gao F, Wang Y-N, Bogaerts A, Plasma sources science and technology 22, 015017 (2013). http://doi.org/10.1088/0963-0252/22/1/015017
Abstract: In this work, a hybrid model is used to investigate the effect of different gas ratios on the Si etching and polymer film deposition characteristics in an Ar/CF4 inductively coupled plasma. The influence of the surface processes on the bulk plasma properties is studied, and also the spatial characteristics of important gas phase and etched species. The densities of F and CF2 decrease when the surface module is included in the simulations, due to the species consumption caused by etching and polymer deposition. The influence of the surface processes on the bulk plasma depends on the Ar/CF4 gas ratio. The deposited polymer becomes thicker at high CF4 content because of more abundant CFx radicals. As a result of the competition between the polymer thickness and the F flux, the etch rate first increases and then decreases upon increasing the CF4 content. The electron properties, more specifically the electron density profile, affect the Si etch characteristics substantially by determining the radical density and flux profiles. In fact, the radial profile of the etch rate is more uniform at low CF4 content since the electron density has a smooth distribution. At high CF4 content, the etch rate is less uniform with a minimum halfway along the wafer radius, because the electron density distribution is more localized. Therefore, our calculations predict that it is better to work at relatively high Ar/CF4 gas ratios, in order to obtain high etch rate and good profile uniformity for etch applications. This, in fact, corresponds to the typical experimental etch conditions in Ar/CF4 gas mixtures as found in the literature, where Ar is typically present at a much higher concentration than CF4.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.302
Times cited: 11
DOI: 10.1088/0963-0252/22/1/015017
|
|
|
“Geothermal water analysis by X-ray fluorescence and neutron activation”. van Grieken R, Gijbels R, Blommaert W, Vandelannoote R, Van 't dack L US Energy Research and Development Administration, S.l., page 368 (1978).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“The glow discharge: an exciting plasma”. Bogaerts A, Journal of analytical atomic spectrometry 14, 1375 (1999). http://doi.org/10.1039/a900772e
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 29
DOI: 10.1039/a900772e
|
|
|
“Glow discharge mass spectrometry, methods”. Bogaerts A Academic Press, San Diego, Calif., page 669 (2000).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Glow discharge modelling: from basic understanding towards applications”. Bogaerts A, Chen Z, Gijbels R, Surface and interface analysis 35, 593 (2003). http://doi.org/10.1002/sia.1578
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.132
Times cited: 14
DOI: 10.1002/sia.1578
|
|
|
“Glow discharge optical emission spectrometry: moving towards reliable thin film analysis: a short review”. Angeli J, Bengtson A, Bogaerts A, Hoffmann V, Hodoroaba V-D, Steers E, Journal of analytical atomic spectrometry 18, 670 (2003). http://doi.org/10.1039/b301293j
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 75
DOI: 10.1039/b301293j
|
|
|
“Glow discharge optical spectroscopy and mass spectrometry”. Steiner RE, Barshick CM, Bogaerts A Wiley, Chichester, page 1 (2009).
Abstract: Optical (atomic absorption spectroscopy, AAS; atomic emission spectroscopy, AES; atomic fluorescence spectroscopy, AFS; and optogalvanic spectroscopy) and mass spectrometric (magnetic sector, quadrupolemass analyzer, QMA; quadrupole ion trap, QIT; Fourier transform ion cyclotron resonance, FTICR; and time-of-flight, TOF) instrumentation are well suited for coupling to the glow discharge (GD). The GD is a relatively simple device. A potential gradient (5001500 V) is applied between an anode and a cathode. In most cases, the sample is also the cathode. A noble gas (e.g. Ar, Ne, and Xe) is introduced into the discharge region before power initiation. When a potential is applied, electrons are accelerated toward the anode. As these electrons accelerate, they collide with gas atoms. A fraction of these collisions are of sufficient energy to remove an electron from a support gas atom, forming an ion. These ions are, in turn, accelerated toward the cathode. These ions impinge on the surface of the cathode, sputtering sample atoms from the surface. Sputtered atoms that do not redeposit on the surface diffuse into the excitation/ionization regions of the plasma where they can undergo excitation and/or ionization via a number of collisional processes. GD sources offer a number of distinct advantages that make them well suited for specific types of analyses. These sources afford direct analysis of solid samples, thus minimizing the sample preparation required for analysis. The nature of the plasma also provides mutually exclusive atomization and excitation processes that help to minimize the matrix effects that plague so many other elemental techniques. Unfortunately, the GD source functions optimally in a dry environment, making analysis of solutions more difficult. These sources also suffer from difficulties associated with analyzing nonconductingsamples. In this article, first, the principles of operation of the GD plasma are reviewed, with an emphasis on how those principles relate to optical spectroscopy and mass spectrometry. Basic applications of the GD techniques are considered next. These include bulk analysis, surface analysis, and the analysis of solution samples. The requirements necessary to obtain optical information are addressed following the analytical applications. This section focuses on the instrumentation needed to make optical measurements using the GD as an atomization/excitation source. Finally, mass spectrometric instrumentation and interfaces are addressed as they pertain to the use of a GD plasma as an ion source. GDsources provide analytically useful gas-phase species from solid samples. These sources can be interfaced with avariety of spectroscopic and spectrometric instruments for both quantitative and qualitative analysis.
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Glow discharges in emission and mass spectrometry”. Jakubowski N, Bogaerts A, Hoffmann V Blackwell, Sheffield (2003).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Gold mobility in waters from temperate regions”. Cidu R, Fanfani L, Shand P, Edmunds WM, Van 't dack L, Gijbels R, (1995)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Grain size tuning of nanocrystalline chemical vapor deposited diamond by continuous electrical bias growth : experimental and theoretical study”. Mortet V, Zhang L, Eckert M, D'Haen J, Soltani A, Moreau M, Troadec D, Neyts E, De Jaeger JC, Verbeeck J, Bogaerts A, Van Tendeloo G, Haenen K, Wagner P, Physica status solidi : A : applications and materials science 209, 1675 (2012). http://doi.org/10.1002/pssa.201200581
Abstract: In this work, a detailed structural and spectroscopic study of nanocrystalline diamond (NCD) thin films grown by a continuous bias assisted CVD growth technique is reported. This technique allows the tuning of grain size and phase purity in the deposited material. The crystalline properties of the films are characterized by SEM, TEM, EELS, and Raman spectroscopy. A clear improvement of the crystalline structure of the nanograined diamond film is observed for low negative bias voltages, while high bias voltages lead to thin films consisting of diamond grains of only ∼10 nm nanometer in size, showing remarkable similarities with so-called ultrananocrystalline diamond. These layers arecharacterized by an increasing amount of sp2-bonded carbon content of the matrix in which the diamond grains are embedded. Classical molecular dynamics simulations support the observed experimental data, giving insight in the underlying mechanism for the observed increase in deposition rate with bias voltage. Furthermore, a high atomic concentration of hydrogen has been determined in these films. Finally, Raman scattering analyses confirm that the Raman line observed at ∼1150 cm−1 cannot be attributed to trans-poly-acetylene, which continues to be reported in literature, reassigning it to a deformation mode of CHx bonds in NCD.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.775
Times cited: 31
DOI: 10.1002/pssa.201200581
|
|