|
“Inelastic scattering of high-energy electrons in a crystal in thermal equilibrium with the environment: 1: theoretical framework”. Fanidis C, van Dyck D, van Landuyt J, Ultramicroscopy 41, 55 (1992). http://doi.org/10.1016/0304-3991(92)90094-Z
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.436
Times cited: 17
DOI: 10.1016/0304-3991(92)90094-Z
|
|
|
“Inelastic scattering of high-energy electrons in a crystal in thermal equilibrium with the environment: part 2: solution of the equations and applications to concrete cases”. Fanidis C, van Dyck D, van Landuyt J, Ultramicroscopy 48, 133 (1993)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.436
Times cited: 6
|
|
|
“Does a monochromator improve the precision in quantitative HRTEM?”.den Dekker AJ, Van Aert S, van Dyck D, van den Bos A, Geuens P, Ultramicroscopy 89, 275 (2001). http://doi.org/10.1016/S0304-3991(01)00089-4
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 22
DOI: 10.1016/S0304-3991(01)00089-4
|
|
|
“Maximum likelihood estimation of structure parameters from high resolution electron microscopy images: part 1: a theoretical framework”. den Dekker AJ, Van Aert S, van den Bos A, van Dyck D, Ultramicroscopy 104, 83 (2005). http://doi.org/10.1016/j.ultramic.2005.03.001
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 70
DOI: 10.1016/j.ultramic.2005.03.001
|
|
|
“On the interpretation of HREM images of partially ordered alloys”. De Meulenaere P, Van Tendeloo G, van Landuyt J, van Dyck D, Ultramicroscopy 60, 265 (1995). http://doi.org/10.1016/0304-3991(95)00065-9
Abstract: The ordering for 11/20 alloys has been studied by high-resolution electron microscopy (HREM). The distribution of the intensity maxima in the HREM image have been statistically examined, which provides a profound basis for the image interpretation. Processing of the HREM images allows ''dark-field'' images to be obtained, exhibiting a two-dimensional distribution of those columns which contain the most information in order to interpret the short-range order correlations. Pair correlations and higher cluster correlations between projected columns can be visualised, providing unique information about the ordering as retrieved from an experimental result without any other assumption. The method has been applied to Au4Cr and to Au4Mn to interpret the quenched short-range order state and the transition to long-range order.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.436
Times cited: 20
DOI: 10.1016/0304-3991(95)00065-9
|
|
|
“Dynamical electron diffraction in substitutionally disordered column structures”. De Meulenaere P, van Dyck D, Van Tendeloo G, van Landuyt J, Ultramicroscopy 60, 171 (1995). http://doi.org/10.1016/0304-3991(95)00040-8
Abstract: For column structures, such as fee-based alloys viewed along the cube direction, the concept of electron channelling through the atom columns is more and more used to interpret the corresponding HREM images. In the case of(partially) disordered columns, the projected potential approach which is used in the channelling description must be questioned since the arrangement of the atoms along the beam direction might affect the exit wave of the electrons. In this paper, we critically inspect this top-bottom effect using multi-slice calculations. A modified channelling theory is introduced which turns out to be very appropriate for the interpretation of these results. For substitutionally disordered column structures, it is also discussed how to link the chemical composition of the material to statistical data of the HREM image. This results in a convenient tool to discern images taken at different thicknesses and focus values.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.436
Times cited: 14
DOI: 10.1016/0304-3991(95)00040-8
|
|
|
“High precision measurements of atom column positions using model-based exit wave reconstruction”. de Backer A, Van Aert S, van Dyck D, Ultramicroscopy 111, 1475 (2011). http://doi.org/10.1016/j.ultramic.2011.07.002
Abstract: In this paper, it has been investigated how to measure atom column positions as accurately and precisely as possible using a focal series of images. In theory, it is expected that the precision would considerably improve using a maximum likelihood estimator based on the full series of focal images. As such, the theoretical lower bound on the variances of the unknown atom column positions can be attained. However, this approach is numerically demanding. Therefore, maximum likelihood estimation has been compared with the results obtained by fitting a model to a reconstructed exit wave rather than to the full series of focal images. Hence, a real space model-based exit wave reconstruction technique based on the channelling theory is introduced. Simulations show that the reconstructed complex exit wave contains the same amount of information concerning the atom column positions as the full series of focal images. Only for thin samples, which act as weak phase objects, this information can be retrieved from the phase of the reconstructed complex exit wave.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 8
DOI: 10.1016/j.ultramic.2011.07.002
|
|
|
“An efficient way of including thermal diffuse scattering in simulation of scanning transmission electron microscopic images”. Croitoru MD, van Dyck D, Van Aert S, Bals S, Verbeeck J, Ultramicroscopy 106, 933 (2006). http://doi.org/10.1016/j.ultramic.2006.04.006
Abstract: We propose an improved image simulation procedure for atomic-resolution annular dark-field scanning transmission electron microscopy (STEM) based on the multislice formulation, which takes thermal diffuse scattering fully into account. The improvement with regard to the classical frozen phonon approach is realized by separating the lattice configuration statistics from the dynamical scattering so as to avoid repetitive calculations. As an example, the influence of phonon scattering on the image contrast is calculated and investigated. STEM image simulation of crystals can be applied with reasonable computing times to problems involving a large number of atoms and thick or large supercells.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Condensed Matter Theory (CMT); Vision lab
Impact Factor: 2.843
Times cited: 18
DOI: 10.1016/j.ultramic.2006.04.006
|
|
|
“Measurement of specimen thickness by phase change determination in TEM”. Croitoru MD, van Dyck D, Liu YZ, Zhang Z, Ultramicroscopy 108, 1616 (2008). http://doi.org/10.1016/j.ultramic.2008.06.002
Abstract: A non-destructive method for measuring the thickness of thin amorphous films composed of light elements has been developed. The method employs the statistics of the phase of the electron exit wave function. The accuracy of this method has been checked numerically by the multislice method and compared with that based on the mean inner potential.
Keywords: A1 Journal article; Condensed Matter Theory (CMT); Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 2
DOI: 10.1016/j.ultramic.2008.06.002
|
|
|
“Holotomography: quantitative phase tomography with micrometer resolution using hard synchrotron radiation X-rays”. Cloetens P, Ludwig W, Baruchel J, van Dyck D, van Landuyt J, Guigay JP, Schlenker M, Applied physics letters 75, 2912 (1999). http://doi.org/10.1063/1.125225
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 3.411
Times cited: 481
DOI: 10.1063/1.125225
|
|
|
“Computational comparisons between the conventional multislice method and the third-order multislice method for calculating high-energy electron diffraction and imaging”. Chen JH, van Dyck D, op de Beeck M, van Landuyt J, Ultramicroscopy 69, 219 (1997)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 11
|
|
|
“Modification of the multislice method for calculating coherent STEM images”. Chen JH, van Dyck D, op de Beeck M, Broeckx J, van Landuyt J, Physica status solidi: A: applied research 150, 13 (1995). http://doi.org/10.1002/pssa.2211500103
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Times cited: 5
DOI: 10.1002/pssa.2211500103
|
|
|
“Enamels in stained-glass windows : preparation, chemical composition, microstructure and causes of deterioration”. Caen J, Schalm O, van der Snickt G, van der Linden V, Frederickx P, Schryvers D, Janssens K, Cornelis E, van Dyck D, Schreiner M, , 121 (2005)
Keywords: P3 Proceeding; Art; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Vision lab
|
|
|
“Statistical estimation of oxygen atomic positions eith sub Ångstrom precision from exit wave reconstruction”. Bals S, Van Aert S, Van Tendeloo G, van Dyck D, Avila-Brande D, Microscopy and microanalysis 11, 556 (2005)
Keywords: A3 Journal article; Electron microscopy for materials research (EMAT); Vision lab
|
|
|
“A peculiar diffraction effect in FCC crystals of C60”. Amelinckx S, van Heurck C, van Dyck D, Van Tendeloo G, Physica status solidi: A: applied research 131, 589 (1992). http://doi.org/10.1002/pssa.2211310231
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Times cited: 13
DOI: 10.1002/pssa.2211310231
|
|
|
Amelinckx S, van Dyck D, van Landuyt J, Van Tendeloo G (1997) Electron microscopy: principles and fundamentals. Vch, Weinheim
Keywords: ME1 Book as editor or co-editor; Electron microscopy for materials research (EMAT); Vision lab
|
|
|
Amelinckx S, van Dyck D, van Landuyt J, Van Tendeloo G (1997) Handbook of microscopy: applications in materials science, solid-state physics and chemistry. Vch, Weinheim
Keywords: ME1 Book as editor or co-editor; Electron microscopy for materials research (EMAT); Vision lab
|
|
|
“How precise can atoms of a nanocluster be located in 3D using a tilt series of scanning transmission electron microscopy images?”.Alania M, De Backer A, Lobato I, Krause FF, Van Dyck D, Rosenauer A, Van Aert S, Ultramicroscopy 181, 134 (2017). http://doi.org/10.1016/j.ultramic.2016.12.013
Abstract: In this paper, we investigate how precise atoms of a small nanocluster can ultimately be located in three dimensions (3D) from a tilt series of images acquired using annular dark field (ADF) scanning transmission electron microscopy (STEM). Therefore, we derive an expression for the statistical precision with which the 3D atomic position coordinates can be estimated in a quantitative analysis. Evaluating this statistical precision as a function of the microscope settings also allows us to derive the optimal experimental design. In this manner, the optimal angular tilt range, required electron dose, optimal detector angles, and number of projection images can be determined.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 3
DOI: 10.1016/j.ultramic.2016.12.013
|
|