|   | 
Details
   web
Records
Author (up) Treiger, B.; van Malderen, H.; Bondarenko, I.; van Espen, P.; Van Grieken, R.
Title Studying aerosol samples by non-linear mapping of electron probe microanalysis data Type A1 Journal article
Year 1993 Publication Analytica chimica acta Abbreviated Journal
Volume 284 Issue Pages 119-124
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos A1993MR27600014 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; 1873-4324 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:6224 Serial 8610
Permanent link to this record
 

 
Author (up) Van Grieken, R.
Title Preconcentration methods for the analysis of water by X-ray spectrometric techniques Type A1 Journal article
Year 1982 Publication Analytica chimica acta Abbreviated Journal
Volume 143 Issue Pages 3-34
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract All published procedures for multi-element preconcentration of trace elements, prior to x-ray fluorescence analysis of water, are reviewed and critically evaluated. Most preconcentration methods applied to the determination of single elements in water are also listed.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos A1982PT27300002 Publication Date 2002-10-14
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; 1873-4324 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116441 Serial 8401
Permanent link to this record
 

 
Author (up) van Grieken, R.; Gijbels, R.; Speecke, A.; Hoste, J.
Title The determination of silicon in steel by 14-mev neutron activation analysis Type A1 Journal article
Year 1968 Publication Analytica chimica acta Abbreviated Journal Anal Chim Acta
Volume 43 Issue Pages 199-209
Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract A fast (25 min) non-destructive determination of silicon in steel by 14-MeV neutron activation is described. The 1.78-MeV 28Al activity, induced by the reaction 28Si(n,p)28Al, is counted on a NaI(Tl) detector. An oxygen flux monitor is used to normalise to the same neutron flux. Two methods are described to correct for the 56Mn activity (2.58 h), induced into the iron matrix via 56Fe(n,p)56Mn. Nuclear interferences of phosphorus and aluminium have been examined. Special attention has been paid to stainless steels. A sensitivity of 0.02 to 0.05% of silicon is obtained. The precision is 2 to 3% for steels containing above 1% silicon, and 7% for 0.1% of silicon.
Address
Corporate Author Thesis
Publisher Place of Publication Amsterdam Editor
Language Wos A1968C007600004 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 4.513 Times cited 19 Open Access
Notes Approved no
Call Number UA @ lucian @ c:irua:116357 Serial 673
Permanent link to this record
 

 
Author (up) van Grieken, R.; Gijbels, R.; Speecke, A.; Hoste, J.
Title Internal standard activation analysis of silicon in steel Type A1 Journal article
Year 1968 Publication Analytica chimica acta Abbreviated Journal Anal Chim Acta
Volume 43 Issue Pages 381-395
Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Non-destructive 14-MeV neutron activation analysis for silicon in steel has been applied with 56Mn as internal standard.56Mn is formed from the iron matrix via the 56Fe(n,p)56Mn reaction. Several methods of internal standardisation via56Mn are discussed. The 0.84-MeV photopeak of 56Mn is recommended if steel samples of about the same composition are to be analysed. Chemically analysed steel samples are used as silicon standards. A precision of 0.7% was obtained for an analysis plus standardisation time of 13 min. Special attention was paid to interferences produced by concentration changes of impurity elements. Several possible sources of errors were investigated.
Address
Corporate Author Thesis
Publisher Place of Publication Amsterdam Editor
Language Wos A1968C185100003 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 4.513 Times cited 14 Open Access
Notes Approved no
Call Number UA @ lucian @ c:irua:116358 Serial 1701
Permanent link to this record
 

 
Author (up) Van Grieken, R.; Speecke, A.; Hoste, J.
Title The determination of copper in iron and steel by 14-Mev neutron activation analysis Type A1 Journal article
Year 1970 Publication Analytica chimica acta Abbreviated Journal
Volume 51 Issue 2 Pages 151-162
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract A fast (10 min) non-destructive determination of copper in. steel and cast iron by 14-MeV neutron activation analysis is described. The 0.511-MeV annihilation radiation of62Cu (T1/2=9.8 min), induced by the reaction63Cu(n,2n)62Cu, is counted by two opposing NaI(Tl) detectors operating in coincidence. An oxygen flux monitor is used to normalise the irradiations. For high phosphorus contents, two measurements are made and the 9-min activity contribution is calculated. As the iron content of the samples is known, the use of pure iron samples allows correction for53Fe activity from the reaction54Fe(n,2n)53Fe(T1/2= 8.9 min). When the phosphorus and silicon activities are low, the procedure of counting and computing can be greatly simplified. Nuclear interferences of most common alloying and impurity elements were investigated.The precision is 23% for steels containing above 1% Cu, andCa. 10% for 0.1%Cu.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos A1970H034700002 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; 1873-4324 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116360 Serial 7778
Permanent link to this record
 

 
Author (up) Van Grieken, R.; Speecke, A.; Hoste, J.
Title On the precision of oxygen determinations in steel by 14-MeVv neutron activation Type A1 Journal article
Year 1970 Publication Analytica chimica acta Abbreviated Journal
Volume 52 Issue 2 Pages 275-280
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract The precision of the 14-MeV neutron activation determination of oxygen in steel has been examined as a function of the oxygen content for a large number of steel and cast iron samples. The experimental and the statistically expected standard deviations have been compared. In the conditions used, 2.5 counts from 16N were registered for each p.p.m. of oxygen in the samples. The neutron flux was monitored by a simultaneously irradiated oxygen standard.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; 1873-4324 ISBN Additional Links UA library record
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116362 Serial 8332
Permanent link to this record
 

 
Author (up) Van Grieken, R.; Van 't dack, L.; Costa Dantas, C.; Da Silveira Dantas, H.
Title Soil analysis by thin-film energy-dispersive X-ray fluorescence Type A1 Journal article
Year 1979 Publication Analytica chimica acta Abbreviated Journal
Volume 108 Issue Pages 93-101
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Energy-dispersive x-ray fluorescence is advantageous for trace analysis of soils present as thin films. A target thickness of about 2 mg cm-2 provides a compromise between optimal sensitivity and minimal absorption effect or optimal accuracy. Sample preparation involves only suspending the finely ground soil in water and drying this suspension on a thin mylar foil glued on a ring that fits into the x.r.f. spectrometer. The effective sample weight present in the exciting beam area is computed from the scatter peaks, a method that cancels out target heterogeneity problems. High accuracy is demonstrated for many elements in reference soil and rock materials; a precision around 5% and a detection limit around 10 ppm can be achieved. As an illustration, results for 16 trace elements and preliminary interpretation are given for a series of pedologically important soil samples from Brasil.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos A1979HL44100012 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; 1873-4324 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:111402 Serial 8549
Permanent link to this record
 

 
Author (up) Van Grieken, R.; Van de Velde, R.; Robberecht, H.
Title Sample contamination from a commercial grinding unit Type A1 Journal article
Year 1980 Publication Analytica chimica acta Abbreviated Journal
Volume 118 Issue 1 Pages 137-143
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract The contamination of ground samples by a commercially available Lovibond McCrone Micronizing Mill is discussed. Tracer and weighing experiments showed that abrasion of corundum grinding elements was important, introducing 620 mg of abrasion products per minute of wet grinding. Agate grinding elements were abraded at ⩽6 mg min-1. The abrasion products and grinding elements were analyzed by x-ray fluorescence, spark-source mass spectrometry and neutron activation analysis. Contamination in trace element analysis of geological materials is likely to be negligible for agate grinding elements and, except for a few transition metals, also for corundum grinding elements. Contamination of typical biological samples is significant for a few elements even when agate elements are used, and is absolutely prohibitive for trace analysis when corundum elements are used.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos A1980JZ95100016 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; 1873-4324 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116436 Serial 8492
Permanent link to this record
 

 
Author (up) Vandecasteele, C.; van Grieken, R.; Gijbels, R.; Speecke, A.
Title Systematic errors in 14-MeV neutron activation analysis for oxygen : part 1 : neutron and γ-ray attenuation effects Type A1 Journal article
Year 1973 Publication Analytica chimica acta Abbreviated Journal Anal Chim Acta
Volume 64 Issue 2 Pages 187-196
Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract A detailed account is given of neutron and γ-ray attenuation effects in 14-MeV neutron activation analysis of oxygen. Appropriate neutron cross-section values have been determined in two different ways and compared with literature values. It appears that the attenuation process is best described in terms of nonelastic scattering cross-sections. It is also shown that the narrow beam total γ-ray attenuation coefficients at 6 MeV, given in the literature are suitable for correction purposes if 16N γ-rays are counted with a window of 4.56.5 MeV. Attention was paid to the contribution of β-rays when the 16N activity is counted in this energy interval with a NaI(Tl) detector.
Address
Corporate Author Thesis
Publisher Place of Publication Amsterdam Editor
Language Wos A1973P353000003 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 4.513 Times cited 11 Open Access
Notes Approved CHEMISTRY, PHYSICAL 54/144 Q2 # PHYSICS, ATOMIC, MOLECULAR & CHEMICAL 9/35 Q2 #
Call Number UA @ lucian @ c:irua:116363 Serial 3464
Permanent link to this record
 

 
Author (up) Vandecasteele, C.; van Grieken, R.; Gijbels, R.; Speecke, A.
Title Systematic errors in 14-MeV neutron activation analysis for oxygen : part 2 : a general standardization method for the determination of oxygen Type A1 Journal article
Year 1973 Publication Analytica chimica acta Abbreviated Journal Anal Chim Acta
Volume 65 Issue 1 Pages 1-17
Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract A general standardization method is described for the determination of oxygen in solid samples via the 16O(n,p)16N reaction. Two systems of flux monitoring are considered: the sample versus standard comparator method and BF3 monitoring. The average flux in sample and standard, fast neutron shielding, fast neutron scattering, absorption of fast neutrons, absorption of 16N γ-rays and counting efficiency of sample and standard are considered. The influence of the target diameter on the obtained correction factors has also been studied. Total achievable accuracy is believed to be about 1%.
Address
Corporate Author Thesis
Publisher Place of Publication Amsterdam Editor
Language Wos A1973Q019300001 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor 4.513 Times cited 12 Open Access
Notes Approved
Call Number UA @ lucian @ c:irua:116364 Serial 3465
Permanent link to this record
 

 
Author (up) Vandecasteele, C.; Van Grieken, R.; Hoste, J.
Title Simultaneous determination of chromium and silicon in steel by 14-mev neutron activation analysis Type A1 Journal article
Year 1974 Publication Analytica chimica acta Abbreviated Journal
Volume 72 Issue 1 Pages 31-36
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Chromium and silicon are determined simultaneously in steel by 14-MeV neutron activation analysis. The activities of 52V(Eγ=1.43 MeV,TView the MathML source=3.76 min) from 52Cr(n,p)52V and 28Al (Eγ=1.78 MeV; TView the MathML source=2.24 min) from 28Si(n,p)28Al are evaluated by mixed γ-ray spectrometry. The influence of manganese and phosphorus, the main interfering elements, is negligible for most stainless steels. The count rate should be limited, to avoid 52V pulse pile-up effects interfering in the 28Al energy region. Precisions in the 2-10% range are reached, depending on the concentrations, for a 10-min analysis time. Results for a series of steel samples are compared with industrial analyses.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos A1974U036600002 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; 1873-4324 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116366 Serial 8527
Permanent link to this record
 

 
Author (up) Vanderborght, B.; Van Grieken, R.
Title Automated evaluation of photographically recorded spark-source mass spectra Type A1 Journal article
Year 1978 Publication Analytica chimica acta Abbreviated Journal
Volume 103 Issue 3 Pages 223-235
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract A computer routine was developed for qualitative and quantitative analysis of photographically recorded spark-source mass spectra. Particular attention is given to the case of a graphite matrix. The program starts from the line intensities (expressed as Seidel values) and isotope masses calculated from the densitometer readings by a commercially available routine. From the intensities in the different exposures (typically 15 stages), it computes the parameters for the linear parts of the density curves for each ion. Taking into account mutual interferences of multivalent ions, isotope or C-clusters, oxide, carbide and dicarbide ions, the program automatically identifies and then quantifies the elements present. The precision of the results is around 5%. Reading and complete processing of one photoplate is achieved within 23 h.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos A1978GD90900003 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; 1873-4324 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:113631 Serial 7538
Permanent link to this record
 

 
Author (up) Vanderborght, B.; Van Grieken, R.
Title Reduction of trace metal levels in analytical-grade activated carbon Type A1 Journal article
Year 1977 Publication Analytica chimica acta Abbreviated Journal
Volume 89 Issue 2 Pages 399-402
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos A1977DB52500022 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; 1873-4324 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116368 Serial 8466
Permanent link to this record
 

 
Author (up) Verbueken, A.H.; Van Grieken, R.E.; de Broe, M.E.; Wedeen, R.P.
Title Identification of inorganic and organic microliths in kidney sections by laser microprobe mass spectrometry Type A1 Journal article
Year 1987 Publication Analytica chimica acta Abbreviated Journal
Volume 195 Issue Pages 97-115
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
Abstract Laser microprobe mass spectrometry is used to identify intrarenal microliths; they appear to consist of either oxalate, urate or phosphate. Crystalline and amorphous deposits in rat and human kidney are pin-pointed by the laser beam and their chemical composition determined by mass spectrometry. The method has the potential for wide application in the identification of single organic, inorganic or combination crystals in histological sections.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos A1987K019500009 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; 1873-4324 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116448 Serial 8055
Permanent link to this record
 

 
Author (up) Vos, L.; Komy, G.; Reggers, G.; Roekens, E.; Van Grieken, R.
Title Determination of trace metals in rain water by differential-pulse stripping voltammetry Type A1 Journal article
Year 1986 Publication Analytica chimica acta Abbreviated Journal
Volume 184 Issue Pages 271-280
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Differential-pulse stripping voltammetry is applied to measure zinc, cadmium, lead and copper by anodic stripping and selenium(IV) by cathodic stripping in rain water at pH 2; subsequently, at pH 9,1, manganese is measured by anodic stripping on the same portion, and cobalt and nickel are measured in the adsorptive mode after formation of their dimethylglyoximates. The instrumental parameters are optimized. The linear ranges, mutual interferences and detection limits are studied. Excellent accuracy is demonstrated; the standard deviation is around 15% at 2.550 μg l−1 levels. The method is shown to be applicable for rain water.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos A1986D964700026 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; 1873-4324 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116444 Serial 7793
Permanent link to this record
 

 
Author (up) Vos, L.; Robberecht, H.; Van Dyck, P.; Van Grieken, R.
Title Multi-element analysis of urine by energy-dispersive x-ray fluorescence spectrometry Type A1 Journal article
Year 1981 Publication Analytica chimica acta Abbreviated Journal
Volume 130 Issue 1 Pages 167-175
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract For multi-element analysis of human urine, 25-ml samples doped with yttrium as internal standard are evaporated gently and then ashed up to 460°C overnight. The residue is pelletized and analysed by energy-dispersive x-ray fluorescence. Acid addition to facilitate the digestion is not mandatory. Recoveries are nearly quantitative for traces of Fe, Ni, Cu, Zn and Sr, to a lesser extent for lead, but not for arsenic or selenium. The standard deviation per measurement is typically around 6%. The detection limits are such that some 10 elements can be determined simultaneously in normal urine, and possibly more in cases of importance to toxicology or industrial hygiene.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos A1981ME98900017 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; 1873-4324 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116439 Serial 8285
Permanent link to this record
 

 
Author (up) Vos, L.; Van Grieken, R.
Title Preparation of conducting electrodes from biological samples for multi-element trace analysis by spark-source mass spectrometry or emission spectrometry Type A1 Journal article
Year 1984 Publication Analytica chimica acta Abbreviated Journal
Volume 164 Issue Pages 83-90
Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract Four decomposition procedures frequently used for biological material (dry ashing, open wet digestion, wet digestion in a teflon bomb and low-temperature ashing) are optimized for the conversion of biological samples to conducting electrodes suitable for multi-element trace determinations by spark-source mass spectrometry or emission spectrometry. The optimized procedures are evaluated with respect to contamination, retention and preconcentration of the trace elements, homogeneity of the electrodes and precision of the final results. Both dry-ashing methods are prone to losses by volatilization; simple dry ashing suffers from contamination problems during electrode preparation. Wet digestion gives better precision; digestion with nitric/sulfuric acids in an open flask is the method of choice for most elements being simpler and giving lower blanks than the bomb method.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos A1984ABC2700007 Publication Date 2002-07-25
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0003-2670; 1873-4324 ISBN Additional Links UA library record; WoS full record; WoS citing articles
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116443 Serial 8411
Permanent link to this record