|
“The use of lead-glass capillaries for microfocusing of highly energetic (0-60 KeV) synchrotron radiation”. Janssens K, Vincze L, Vekemans B, Adams F, Haller M, Knöchel A, Journal of analytical atomic spectrometry 13, 339 (1998). http://doi.org/10.1039/A707700I
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
DOI: 10.1039/A707700I
|
|
|
“Use of microscopic XRF for non-destructive analysis in art an archaeometry”. Janssens K, Vittiglio G, Deraedt I, Aerts A, Vekemans B, Vincze L, Wei F, de Ryck I, Schalm O, Adams F, Rindby A, Knöchel A, Simionovici AS, Snigirev A, X-ray spectrometry 29, 73 (2000). http://doi.org/10.1002/(SICI)1097-4539(200001/02)29:1<73::AID-XRS416>3.3.CO;2-D
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
DOI: 10.1002/(SICI)1097-4539(200001/02)29:1<73::AID-XRS416>3.3.CO;2-D
|
|
|
“The use of scanning X-ray microprobe for simultaneous XRF/XRD studies of fly-ash particles”. Rindby A, Engström P, Janssens K, Journal of synchotron radiation 4, 228 (1997)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“The use of synchrotron micro-XRF for characterisation of the micro-heterogeneity of low-Z reference materials”. Kempenaers L, Vincze L, Janssens K, Spectrochimica acta: part B : atomic spectroscopy 55, 651 (2000). http://doi.org/10.1016/S0584-8547(00)00207-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(00)00207-X
|
|
|
“The use of synchrotron micro-XRF for characterisation of the micro-heterogeneity of low-Z reference materials containing heavy metals”. Kempenaers L, Vincze L, Janssens K (1999).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Virtual underpainting reconstruction from X-ray fluorescence imaging data”. Anitha A, Brasoveanu A, Duarte MF, Hughes SM, Daubechies I, Dik J, Janssens K, Alfeld M, , 1239 (2011)
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“X-ray based methods of analysis”. Janssens K page 129 (2004).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“X-ray fluorescence analysis”. Janssens K (2003).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“X-ray fluorescence microtomography”. Chukalina M, Simionovici AS, Snigirev A, Drakopoulos M, Snigireva I, Adams F, Janssens K, Poverhnost 3, 40 (2001)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“X-ray fluorescence microtomography: experiment and reconstruction”. Simionovici AS, Chukalina M, Drakopoulos M, Snigireva I, Snigirev A, Schroer C, Lengeler B, Janssens K, Adams F page 304 (1999).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“X-ray microanalysis: a new tool for environmental analysis”. Adams F, Janssens K page 183 (1996).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“μ-XANES speciation of Zn in rhizospheric soil and in edible plants grown on a polluted soil amended with compost”. Terzano R, al Chami Z, Vekemans B, Janssens K, Miano T, Ruggiero P (2007).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“XRS activities at the Micro &, Trace Analysis Centre (MiTAC), University of Antwerp, Belgium”. Padilla R, Janssens K, van Espen P, Van Grieken R, IAEA XRF newsletter 12, 13 (2006)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
|
|
“Zinc distribution and speciation within rocket plants (Eruca vesicaria L. Cavalieri) grown on a polluted soil amended with compost as determined by XRF microtomography and Micro-Xanes”. Terzano R, al Chami Z, Vekemans B, Janssens K, Miano T, Ruggiero P, Journal of agricultural and food chemistry 56, 3222 (2008). http://doi.org/10.1021/JF073304E
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.154
Times cited: 68
DOI: 10.1021/JF073304E
|
|
|
“Caractérisation historique et chimique des peintures en grisaille et du verre de vitrail dans l'oeuvre de J.-B. Capronnier (1814 –, 1891) et J.-B. Bethune (1821 –, 1894)”. Caen J, Schalm O, Janssens K, (2000)
Keywords: P3 Proceeding; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“EXRS2022 : the 2022 edition of the European X-ray Spectrometry conference, held in Bruges, Belgium”. Janssens K, X-ray spectrometry 52, 276 (2023). http://doi.org/10.1002/XRS.3386
Keywords: Editorial; Antwerp X-ray Imaging and Spectroscopy (AXIS)
Impact Factor: 1.2
DOI: 10.1002/XRS.3386
|
|
|
“Reconstructing Sweerts : practical insights into the historical dark halo technique based on paint reconstructions”. Derks K, Youchaeva M, Van der Snickt G, Van der Stighelen K, Janssens K, , 259 (2024)
Keywords: P1 Proceeding; Engineering sciences. Technology; Art; Antwerp Cultural Heritage Sciences (ARCHES); Antwerp X-ray Imaging and Spectroscopy (AXIS)
|
|
|
“Magnetic field dependence of the properties of excitons confined in a quantum disk”. Janssens KL, Peeters FM, Schweigert VA, Physica status solidi: B: basic research 224, 763 (2001). http://doi.org/10.1002/(SICI)1521-3951(200104)224:3<763::AID-PSSB763>3.0.CO;2-9
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 1.674
Times cited: 1
DOI: 10.1002/(SICI)1521-3951(200104)224:3<763::AID-PSSB763>3.0.CO;2-9
|
|
|
“Large-area elemental imaging reveals Van Eyck's original paint layers on the Ghent altarpiece (1432), rescoping its conservation treatment”. van der Snickt G, Dubois H, Sanyova J, Legrand S, Coudray A, Glaude C, Postec M, van Espen P, Janssens K, Angewandte Chemie: international edition in English 56, 4797 (2017). http://doi.org/10.1002/ANIE.201700707
Abstract: A combination of large-scale and micro-scale elemental imaging, yielding elemental distribution maps obtained by, respectively non-invasive macroscopic X-ray fluorescence (MA-XRF) and by secondary electron microscopy/energy dispersive X-ray analysis (SEM-EDX) and synchrotron radiation-based micro-XRF (SR m-XRF) imaging was employed to reorient and optimize the conservation strategy of van Eyck's renowned Ghent Altarpiece. By exploiting the penetrative properties of X-rays together with the elemental specificity offered by XRF, it was possible to visualize the original paint layers by van Eyck hidden below the overpainted surface and to simultaneously assess their condition. The distribution of the high-energy Pb-L and Hg-L emission lines revealed the exact location of hidden paint losses, while Fe-K maps demonstrated how and where these lacunae were filled-up using an iron-containing material. The chemical maps nourished the scholarly debate on the overpaint removal with objective, chemical arguments, leading to the decision to remove all skillfully applied overpaints, hitherto interpreted as work by van Eyck. MA-XRF was also employed for monitoring the removal of the overpaint during the treatment phase. To gather complementary information on the in-depth layer build-up, SEM-EDX and SR mu-XRF imaging was used on paint cross sections to record microscale elemental maps.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 11.994
Times cited: 11
DOI: 10.1002/ANIE.201700707
|
|
|
“Full spectral XANES imaging using the Maia detector array as a new tool for the study of the alteration process of chrome yellow pigments in paintings by Vincent van Gogh”. Monico L, Janssens K, Alfeld M, Cotte M, Vanmeert F, Ryan CG, Falkenberg G, Howard DL, Brunetti BG, Miliani C, Journal of analytical atomic spectrometry 30, 613 (2015). http://doi.org/10.1039/C4JA00419A
Abstract: A combination of synchrotron radiation (SR) micro X-ray fluorescence (m-XRF) and XRF mode X-ray absorption near edge structure (XANES) measurements at the Cr K-edge already allowed us to establish that the photo-reduction of chromates to Cr(III) compounds is the cause of darkening of chrome yellow pigments (PbCr1-xSxO4, 0 <= x <= 0.8) in a number of paintings by Vincent van Gogh and in corresponding artificially aged paint models. A silicon drift detector (SDD) was employed to record the Cr-K XRF radiation in these X-ray micro beam-based measurements. However, in view of the limited count rate capabilities and collection solid angle of a single device, m-XRF and m-XANES employing single element SDDs (or similar) are primarily suited for collection of spectral data from individual points. Additionally, collection of XRF maps via point-by-point scanning with relatively long dwell times per point is possible but is usually confined to small areas. The development of the 384 silicon-diode array Maia XRF detector has provided valuable solutions in terms of data acquisition rate, allowing for full spectral (FS) XANES imaging in XRF mode, i.e., where spectroscopic information is available at each pixel in the scanned map. In this paper, the possibilities of SR Cr K-edge FS-XANES imaging in XRF mode using the Maia detector are examined as a new data collection strategy to study the speciation and distribution of alteration products of lead chromate-based pigments in painting materials. The results collected from two micro-samples taken from two Van Gogh paintings and an aged paint model show the possibility to perform FS-XANES imaging in practical time frames (from several minutes to a few hours) by scanning regions of sample sizes of the same order (more than 500 mm). The sensitivity and capabilities of FS-XANES imaging in providing representative chemical speciation information at the microscale (spatial resolution from similar to 2 to 0.6 mm) over the entire scanned area are demonstrated by the identification of Cr(OH) 3, Cr(III) sulfates and/or Cr(III) organometallic compounds in the corresponding phase maps, as alteration products. Comparable Cr-speciation results were obtained by performing equivalent higher spatial resolution SR m-XRF/single-point m-XANES analysis using a more conventional SDD from smaller regions of interest of each sample. Thus, large-area XRF mode FS-XANES imaging (Maia detector) is here proposed as a valuable and complementary data collection strategy in relation to “ zoomed-in” high-resolution m-XRF mapping and single-point m-XANES analysis (SDD).
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 28
DOI: 10.1039/C4JA00419A
|
|
|
“Solid state speciation and potential bioavailability of depleted uranium particles from Kosovo and Kuwait”. Lind OC, Salbu B, Skipperud L, Janssens K, Jaroszewicz J, de Nolf W, Journal of environmental radioactivity 100, 301 (2009). http://doi.org/10.1016/J.JENVRAD.2008.12.018
Abstract: A combination of synchrotron radiation based X-ray microscopic techniques (ì-XRF, ì-XANES, ì-XRD) applied on single depleted uranium (DU) particles and semi-bulk leaching experiments has been employed to link the potential bioavailability of DU particles to site-specific particle characteristics. The oxidation states and crystallographic forms of U in DU particles have been determined for individual particles isolated from selected samples collected at different sites in Kosovo and Kuwait that were contaminated by DU ammunition during the 1999 Balkan conflict and the 1991 Gulf war. Furthermore, small soil or sand samples heavily contaminated with DU particles were subjected to simulated gastrointestinal fluid (0.16 M HCl) extractions. Characteristics of DU particles in Kosovo soils collected in 2000 and in Kuwait soils collected in 2002 varied significantly depending on the release scenario and to some extent on weathering conditions. Oxidized U (+6) was determined in large, fragile and bright yellow DU particles released during fire at a DU ammunition storage facility and crystalline phases such as schoepite (UO3·2.25H2O), dehydrated schoepite (UO3·0.75H2O) and metaschoepite (UO3·2.0H2O) were identified. As expected, these DU particles were rapidly dissolved in 0.16 M HCl (84 ± 3% extracted after 2 h) indicating a high degree of potential mobility and bioavailability. In contrast, the 2 h extraction of samples contaminated with DU particles originating either from corrosion of unspent DU penetrators or from impacted DU ammunition appeared to be much slower (2030%) as uranium was less oxidized (+4 to +6). Crystalline phases such as UO2, UC and metallic U or UTi alloy were determined in impacted DU particles from Kosovo and Kuwait, while the UO2,34 phase, only determined in particles from Kosovo, could reflect a more corrosive environment. Although the results are based on a limited number of DU particles, they indicate that the structure and extractability of DU particles released from similar sources (metallic U penetrators) will depend on the release scenarios (fire, impact) and to some extent environmental conditions. However, most of the DU particles (7396%) in all investigated samples were dissolved in 0.16 M HCl after one week indicating that a majority of the DU material is bioaccessible.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.31
Times cited: 49
DOI: 10.1016/J.JENVRAD.2008.12.018
|
|
|
“Synchrotron XRF analysis identifies cerium accumulation colocalized with pharyngeal deformities in CeO₂, NP-exposed caenorhabditis elegans”. Rossbach LM, Brede DA, Nuyts G, Cagno S, Olsson RMS, Oughton DH, Falkenberg G, Janssens K, Lind OC, Environmental science and technology 56, 5081 (2022). http://doi.org/10.1021/ACS.EST.1C08509
Abstract: A combination of synchrotron radiation-based elementalimaging, in vivo redox status analysis, histology, and toxic responses was usedto investigate the uptake, biodistribution, and adverse effects of Cenanoparticles (CeO2NP; 10 nm; 0.5-34.96 mg Ce L-1) or Ce(NO3)3(2.3-26 mg Ce L-1)inCaenorhabditis elegans. Elemental mapping of theexposed nematodes revealed Ce uptake in the alimentary canal prior todepuration. Retention of CeO2NPs was low compared to that of Ce(NO3)3in depurated individuals. X-rayfluorescence (XRF) mapping showed that Cetranslocation was confined to the pharyngeal valve and foregut. Ce(NO3)3exposure significantly decreased growth, fertility, and reproduction, causedslightly reduced fecundity. XRF mapping and histological analysis revealedsevere tissue deformities colocalized with retained Ce surrounding thepharyngeal valve. Both forms of Ce activated the sod-1 antioxidant defense,particularly in the pharynx, whereas no significant effects on the cellular redox balance were identified. The CeO2NP-induceddeformities did not appear to impair the pharyngeal function or feeding ability as growth effects were restricted to Ce(NO3)3exposure. The results demonstrate the utility of integrated submicron-resolution SR-based XRF elemental mapping of tissue-specificdistribution and adverse effect analysis to obtain robust toxicological evaluations of metal-containing contaminants.
Keywords: A1 Journal article; Antwerp X-ray Imaging and Spectroscopy (AXIS)
Impact Factor: 11.4
DOI: 10.1021/ACS.EST.1C08509
|
|
|
“Synchrotron-based X-ray fluorescence imaging elucidates uranium toxicokinetics in Daphnia magna”. Byrnes I, Rossbach LM, Brede DA, Grolimund D, Sanchez DF, Nuyts G, Cuba V, Reinoso-Maset E, Salbu B, Janssens K, Oughton D, Scheibener S, Teien H-C, Lind OC, ACS nano 17, 5296 (2023). http://doi.org/10.1021/ACSNANO.2C06111
Abstract: A combination of synchrotron-based elemental anal-ysis and acute toxicity tests was used to investigate the biodistribution and adverse effects in Daphnia magna exposed to uranium nanoparticle (UNP, 3-5 nm) suspensions or to uranium reference (Uref) solutions. Speciation analysis revealed similar size distributions between exposures, and toxicity tests showed com-parable acute effects (UNP LC50: 402 mu g L-1 [336-484], Uref LC50: 268 mu g L-1 [229-315]). However, the uranium body burden was 3 -to 5-fold greater in UNP-exposed daphnids, and analysis of survival as a function of body burden revealed a similar to 5-fold higher specific toxicity from the Uref exposure. High-resolution X-ray fluorescence elemental maps of intact, whole daphnids from sublethal, acute exposures of both treatments revealed high uranium accumulation onto the gills (epipodites) as well as within the hepatic ceca and the intestinal lumen. Uranium uptake into the hemolymph circulatory system was inferred from signals observed in organs such as the heart and the maxillary gland. The substantial uptake in the maxillary gland and the associated nephridium suggests that these organs play a role in uranium removal from the hemolymph and subsequent excretion. Uranium was also observed associated with the embryos and the remnants of the chorion, suggesting uptake in the offspring. The identification of target organs and tissues is of major importance to the understanding of uranium and UNP toxicity and exposure characterization that should ultimately contribute to reducing uncertainties in related environmental impact and risk assessments.
Keywords: A1 Journal article; Engineering sciences. Technology; Antwerp X-ray Imaging and Spectroscopy (AXIS)
Impact Factor: 17.1
DOI: 10.1021/ACSNANO.2C06111
|
|
|
“The darkening of copper- or lead-based pigments explained by a structural modification of natural orpiment : a spectroscopic and electrochemical study”. Vermeulen M, Sanyova J, Janssens K, Nuyts G, De Meyer S, De Wael K, Journal of analytical atomic spectrometry 32, 1331 (2017). http://doi.org/10.1039/C7JA00047B
Abstract: A combined Raman and electrochemical study of natural orpiment (As2S3), an arsenic sulfide pigment, was used to assess the quick formation of oxidized species such as arsenic oxide (As2O3) upon exposing the pigment to 405 nm or 532 nm monochromatic light while simultaneously recording the Raman spectra of the exposed sample. During this process, a distortion of the main band at 355 cm−1, associated with the stretching of the AsS3/2 pyramids of natural orpiment, was observed as well as an increased intensity of the 359 cm−1 band, corresponding to covalent AsAs bonds in natural orpiment. The distortion was accompanied by an overall decrease of the global Raman signal for natural orpiment, which could be explained by a loss in the crystal structure. The same phenomena were recorded in reference natural orpiment model paint samples stored for a long time together with verdigris (Cu(OH)2·(CH3COO)2·5H2O) and minium (Pb3O4) paints, the latter two appearing darkened on their sides closest to the orpiment sample as well as in several historical samples containing natural orpiment mixed with various blue pigments. By SEM-EDX and XRPD analysis, respectively on loose material and cast thin-sections of model paint samples, the darkening was identified as dark sulfide species such as chalcocite (Cu2S) and galena (PbS), suggesting the release of volatile sulfide or related species by the natural orpiment paint. XANES analyses of paint samples presenting AsAs bond increase indicated the presence of sulfur species most likely identified as organosulfur compounds formed upon the AsAs bond formation and explained the darkening of the Cu- and Pb-based pigments. To the best of our knowledge, this article reports for the first time the light-induced formation of AsAs bonds in natural orpiment used as an artists' pigment and objectively demonstrates the incompatibility between orpiment and (arsenic) sulfide-sensitive pigments.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 10
DOI: 10.1039/C7JA00047B
|
|
|
“Strain and band edges in single and coupled cylindrical InAs/GaAs and InP/InGaP self-assembled quantum dots”. Tadić, M, Peeters FM, Janssens KL, Korkusinski M, Hawrylak P, Journal of applied physics 92, 5819 (2002). http://doi.org/10.1063/1.1510167
Abstract: A comparative study is made of the strain distribution in cylindrical InAs/GaAs and InP/InGaP self-assembled quantum dots as obtained from isotropic elasticity theory, the anisotropic continuum mechanical model, and from atomistic calculations. For the isotropic case, the recently proposed approach [J. H. Davies, J. Appl. Phys. 84, 1358 (1998)] is used, while the finite-element method, the valence force field method, and Stillinger-Weber potentials are employed to calculate the strain in anisotropic structures. We found that all four methods result in strain distributions of similar shapes, but with notable quantitative differences inside the dot and near the disk-matrix boundary. The variations of the diagonal strains with the height of the quantum dot, with fixed radius, as calculated from all models, are almost linear. Furthermore, the energies of the band edges in the two types of quantum dots are extracted from the multiband effective-mass theory by inserting the strain distributions as obtained by the four models. We demonstrated that all strain models produce effective potentials for the heavy and light holes which agree very well inside the dot. A negligible anisotropy of all normal strains in the (x,y) plane is found, which, providing the axial symmetry of the kinetic part of the multiband effective-mass Hamiltonian, justifies the use of the axial approximation. Strain propagation along the vertical direction is also considered with the aim to study the influence of strain on the electron coupling in stacks of quantum dots. We found that the interaction between the strain fields of the individual quantum dots makes the effective quantum wells for the electrons in the conduction band shallower, thereby counteracting the quantum mechanical coupling. (C) 2002 American Institute of Physics.
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 2.068
Times cited: 73
DOI: 10.1063/1.1510167
|
|
|
“Semi-quantitative analysis of the formation of a calcium oxalate protective layer for monumental limestone using combined micro-XRF and micro-XRPD”. Vanmeert F, Mudronja D, Fazinic S, Janssens K, Tibljas D, X-ray spectrometry 42, 256 (2013). http://doi.org/10.1002/XRS.2486
Abstract: A current method for the protection of cretaceous limestone present in various monuments consists of performing a passivating treatment with ammonium oxalate (AmOx). A calcium oxalate protective layer is formed on the surface and enhances the acid resistance of the stone. The in-depth formation of the calcium oxalate layer was investigated on cross sections by using combined micro X-ray fluorescence and micro X-ray powder diffraction (mu XRF/mu XRPD). XRPD showed the presence of both whewellite and weddellite in the calcite stone matrix. A correction was made for sample misalignment, which was visible in both the fluorescence and the diffraction line measurements. A semi-quantitative analysis was performed on the basis of Klug's equation for a two-phase mixture (the presence of weddellite was neglected) without the need for a known reference sample. By assuming two extreme compositions for a reference weight fraction (1 and 99wt%), it was possible to obtain whewellite concentration profiles, which can be used for comparing the effectiveness of different methods for the application of AmOx to the stone surface and the effect of treatment time and AmOx concentration used. It is shown that for the relative amounts of whewellite formed, the differences due to the assumed weight fractions are smaller than the errors due to sample heterogeneity and preferred orientation. Copyright (c) 2013 John Wiley & Sons, Ltd.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 5
DOI: 10.1002/XRS.2486
|
|
|
“A general Monte-Carlo simulation of energy-dispersive X-ray fluorescence spectrometers : 1 : unpolarized radiation, homogenious samples”. Vincze L, Janssens K, Adams F, Spectrochimica acta: part B : atomic spectroscopy 48, 553 (1993). http://doi.org/10.1016/0584-8547(93)80060-8
Abstract: A general Monte Carlo program for the simulation of X-ray fluorescence (XRF) spectrometers is presented. The global layout of the program is discussed and the way in which variance reduction techniques have been employed to improve the efficiency of the code is described. For the case of polychromatic excitation in a direct excitation energy-dispersive (ED) XRF instrument, experimentally collected ED-XRF spectra are compared with simulated spectral distributions. Applications of the software in the field of quantitative analysis and thickness estimation of samples of intermediate thickness illustrate the potential of the method.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0584-8547(93)80060-8
|
|
|
“Insights into the composition of ancient Egyptian red and black inks on papyri achieved by synchrotron-based microanalyses”. Christiansen T, Cotte M, de Nolf W, Mouro E, Reyes-Herrera J, De Meyer S, Vanmeert F, Salvado N, Gonzalez V, Lindelof PE, Mortensen K, Ryholt K, Janssens K, Larsen S, Proceedings Of The National Academy Of Sciences Of The United States Of America 117, 27825 (2020). http://doi.org/10.1073/PNAS.2004534117
Abstract: A hitherto unknown composition is highlighted in the red and black inks preserved on ancient Egyptian papyri from the Roman period (circa 100 to 200 CE). Synchrotron-based macro-X-ray fluo-rescence (XRF) mapping brings to light the presence of iron (Fe) and lead (Pb) compounds in the majority of the red inks inscribed on 12 papyrus fragments from the Tebtunis temple library. The iron-based compounds in the inks can be assigned to ocher, notably due to the colocalization of Fe with aluminum, and the detection of hematite (Fe2O3) by micro-X-ray diffraction. Using the same techniques together with micro-Fourier transform infrared spectroscopy, Pb is shown to be associated with fatty acid phosphate, sulfate, chloride, and carboxylate ions. Moreover, microXRF maps reveal a peculiar distribution and colocalization of Pb, phosphorus (P), and sulfur (S), which are present at the micrometric scale resembling diffused “coffee rings” surrounding the ocher particles imbedded in the red letters, and at the submicrometric scale concentrated in the papyrus cell walls. A similar Pb, P, and S composition was found in three black inks, suggesting that the same lead components were employed in the manufacture of carbon-based inks. Bearing in mind that pigments such as red lead (Pb3O4) and lead white (hydrocerussite [Pb-3(CO3)(2)(OH)(2)] and/or cerussite [PbCO3]) were not detected, the results presented here suggest that the lead compound in the ink was used as a drier rather than as a pigment. Accordingly, the study calls for a reassessment of the composition of lead-based components in ancient Mediterranean pigments.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 11.1
DOI: 10.1073/PNAS.2004534117
|
|
|
“Composition and state of alteration of 18th-century glass finds found at the Cistercian nunnery of Clairefontaine, Belgium”. Hellemans K, Vincke A, Cagno S, Herremans D, De Clercq W, Janssens K, Journal of archaeological science 47, 121 (2014). http://doi.org/10.1016/J.JAS.2014.03.039
Abstract: A hundred 18th-century glass fragments were recovered at the Clairefontaine monastery in the Belgian province of Luxembourg. They were analysed by a combination of SEM-EDX and LA-ICP-MS in order to determine their major composition as well as their trace element signature. Multivariate statistical methods such as hierarchical clustering and principal component analysis were used to divide the glass fragments into four main groups: potassium-rich glass, sodium-rich glass, potassium/lime-rich glass and high-lime-low-alkali glass. Within every group, not only a similarity in composition is observed, but also in colour, morphology and deterioration patterns. Potash glass fragments are the most abundant and show extensive deterioration; two classes of potash glass were identified: one similar to certain Central European glass compositions, while the other one, characterised by large variations in potash: lime ratio, may be attributed to local (regional) glass production. (C) 2014 Elsevier Ltd. All rights reserved.
Keywords: A1 Journal article; Philosophy; History; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.602
Times cited: 12
DOI: 10.1016/J.JAS.2014.03.039
|
|
|
“Development of a new portable X-ray powder diffractometer and its demonstration to on-site analysis of two selected old master paintings from the Rijksmuseum”. Hirayama A, Abe Y, van Loon A, De Keyser N, Noble P, Vanmeert F, Janssens K, Tantrakarn K, Taniguchi K, Nakai I, Microchemical journal 138, 266 (2018). http://doi.org/10.1016/J.MICROC.2018.01.003
Abstract: A portable X-ray powder diffractometer (p-XRD) PT-APXRD III has been developed for onsite analysis of paintings and archaeological samples. By using a Cu anode X-ray tube and a silicon drift diode (SDD) detector, diffraction patterns with a high signalnoise (S/N) ratio can be recorded. The X-ray tube can be operated at a maximum voltage of 60 kV, which makes it possible to simultaneously record X-ray fluorescence spectra up to the high-energy region. The total weight of this instrument is 16 kg, which can be carried anywhere and the goniometer unit (5.6 kg) can be placed on a tripod for analysis of mural paintings. We brought the instrument to the Rijksmuseum in the Netherlands to examine its applicability for the analysis of oil paintings. We successfully analyzed two seventeenthcentury oil paintings by Johannes Vermeer and Jan Davidsz de Heem (copy after). Ultramarine blue, leadtin yellow type I, and Naples yellow were identified from the diffraction patterns, demonstrating the high practicality of this instrument. Furthermore, it was found from the SEM-EDX analysis of a paint cross section that the yellow pigment was applied in separate layers rather than being mixed. This diffractometer will be commercially available in the near future and will have many applications in the field of material analysis. (C) 2018 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.034
Times cited: 2
DOI: 10.1016/J.MICROC.2018.01.003
|
|