|   | 
Details
   web
Records
Author Van Grieken, R.E.; Johansson, T.B.; Winchester, J.W.; Odom, L.
Title Micro-determination of zirconium-hafnium ratios in zircons by proton induced X-ray emission Type A3 Journal article
Year (down) 1975 Publication Fresenius' Zeitschrift für analytische Chemie Abbreviated Journal
Volume 275 Issue 5 Pages 343-348
Keywords A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract The zirconium/hafnium ratios of zircons are determined using proton induced X-ray emission. Submilligram samples, imbedded in a starch layer and deposited on a 50 μg/cm2 polystyrene carrier, are irradiated for 1020 min with a 5 nA beam of 3.7 MeV protons, while the Hf-Lβ and Zr-Kα X-rays are counted with a Si(Li) detector. The standard deviation per analysis is in the 36 % range. Only few interferences are possible. To eliminate errors due to absorption effects the zircon layer thickness should be above 40 μm or reproducibly thin samples should be employed. Measuring the Hf-Lβ/Hf-Lα ratio for samples and standards might provide a practical check for the absence of absorption errors. The sensitivity is so favourable that, in practice, the minimal sample size is only limited by the minimal amount that can be handled properly.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos Publication Date 2004-11-11
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0016-1152 ISBN Additional Links UA library record
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116636 Serial 8231
Permanent link to this record
 

 
Author Van Grieken, R.; Speecke, A.; Hoste, J.
Title Geometry errors in 14 MeV neutron activation analysis Type A3 Journal article
Year (down) 1973 Publication Journal of radioanalytical chemistry Abbreviated Journal
Volume 13 Issue 1 Pages 225-233
Keywords A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract The effects of inaccurate sample sizes and sample positioning on 14 MeV neutron activation analysis results are estimated for 30, 20 and 10 mm diameter targets. It appears that axial positioning is the most critical parameter and that using a larger tritium target will yield an overall improvement of the reproducibility.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos Publication Date 2006-10-11
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0134-0719; 2064-2857 ISBN Additional Links UA library record
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116453 Serial 7999
Permanent link to this record
 

 
Author Van Grieken, R.; Speecke, A.; Hoste, J.
Title Spatial neutron flux distributions around A 14 MeV neutron generator Type A3 Journal article
Year (down) 1972 Publication Journal of radioanalytical chemistry Abbreviated Journal
Volume 10 Issue 1 Pages 95-104
Keywords A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract The neutron flux distribution in the vicinity of 30, 20 and 10 mm diameter targets is measured by irradiating concentric ring-type iron monitors at different distances from the target and counting the induced56Mn activity. Considering the many uncertainties, satisfactory agreement was found between theory and experiment.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos Publication Date 2006-11-07
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0134-0719; 2064-2857 ISBN Additional Links UA library record
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116452 Serial 8567
Permanent link to this record
 

 
Author Van Schandevijl, R.; Van Grieken, R.; Hoste, J.
Title The half-life of 28Al Type A3 Journal article
Year (down) 1971 Publication Journal of radioanalytical chemistry Abbreviated Journal
Volume 9 Issue 1 Pages 55-60
Keywords A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract The half-life of28Al was redetermined on aluminium samples of different origin. Three different counting techniques were applied. The availability of highly purified samples (up to 99.9999%), the use of very fast electronic counting equipment and a complete automatisation allowed a good precision to be obtained in the final result of 2.2405 min.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos Publication Date 2006-10-11
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0134-0719; 2064-2857 ISBN Additional Links UA library record
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116451 Serial 8016
Permanent link to this record
 

 
Author Van Grieken, R.; Speecke, A.; Hoste, J.
Title Simultaneous determination of silicon and phosphorus in cast iron by 14 MeV neutron activation analysis Type A3 Journal article
Year (down) 1970 Publication Journal of radioanalytical chemistry Abbreviated Journal
Volume 6 Issue 2 Pages 385-398
Keywords A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Abstract A fast (10 min), non-destructive simultaneous determination of silicon and phosphorus in cast iron and steel by 14 MeV neutron activation was developed. The 1.78 MeV28Al activity (T=2.24 min) induced by the reaction28Si(n, p)28Al is counted on a NaI(Tl) detector. Two measurements are made to correct for the 1.81 MeV56Mn activity (T=2.58 hr) from the iron matrix. However,28Al is also produced via31P(n, α)28Al. By (n, 2n) reaction, phosphorus yields also30P (T=2.6 min), the 0.511 MeV annihilation radiation of which is counted by two opposite NaI(Tl) detectors in coincidence. Again, two successive coincidence measurements are carried out in order to take into account the53Fe activity (β+; T=8.9 min) from54Fe(n, 2n)53Fe. The28Al measurement is appropriately corrected via the computed phosphorus content. An oxygen flux monitor was used to normalize to the same flux. Nuclear interferences have been examined. Special attention has been paid to the presence of copper. The standard deviation for phosphorus being as high as ca. 0.09% P for a single determination, this technique can only be practical as an independent phosphorus analysis for high phosphorus cast irons. The precision on the28Al measurement is 5% relative for 0.2% Si and 2.5% above 1% Si.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Wos Publication Date 2006-10-11
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0134-0719; 2064-2857 ISBN Additional Links UA library record
Impact Factor Times cited Open Access
Notes Approved no
Call Number UA @ admin @ c:irua:116450 Serial 8528
Permanent link to this record