|
Records |
Links |
|
Author |
Hrdlickova Kuckova, S.; Hamidi-Asl, E.; Sofer, Z.; Marvan, P.; De Wael, K.; Sanyova, J.; Janssens, K. |
|
|
Title |
A simplified protocol for usage of new immuno-SERS probes for detection of casein, collagens and ovalbumin in cross-sections of artworks |
Type |
A1 Journal article |
|
Year |
2018 |
Publication |
Analytical methods |
Abbreviated Journal |
Anal Methods-Uk |
|
|
Volume |
10 |
Issue |
9 |
Pages |
1054-1062 |
|
|
Keywords |
A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Although it is now relatively straightforward to identify protein binders in works of art, their proper localization within the corresponding layer still represents a significant analytical challenge. Until now, the identification of proteins has mainly been performed by peptide mass fingerprinting using mass spectrometric methods and their localization in polished paint cross-sections have been realized by optical microscopy via the use of fluorescent stain Sypro Ruby (SR). In this work we propose a simplified protocol for immuno-surface enhanced Raman scattering (immuno-SERS) using gold nanoparticles attached to biphenyl-4,4-dithiol (BPDT) as the SERS-nanotag. These nanoparticles are easily obtainable in the lab and have been used to label multilayered mock up samples prepared as cross-sections to estimate the detection limits of the suggested method. The layers contain egg, casein, and different animal glues binders (prepared in various ratios with linseed oil or a carbohydrate component) mixed with the pigments azurite, vermilion and chalk. The sensitivity of staining agent SR is compared to that of the immuno-SERS protocol for the first time. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000426696100017 |
Publication Date |
2018-02-02 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1759-9660 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.9 |
Times cited |
3 |
Open Access |
|
|
|
Notes |
; The authors wish to acknowledge the Fund for Scientific Research-Flanders (FWO-Vlaanderen) for the support to act as a Postdoctoral Fellow – Pegasus of the Research Foundation – Flanders, and the grant from Specific University research (MSMT No. 20/2017) from the Czech Republic. This work was supported by the project Advanced Functional Nanorobots (reg. No. CZ.02.1.01/0.0/0.0/15_003/ 0000444 financed by the EFRR). Zdenek Sofer and Petr Marvan were supported by specific university research (MSMT No. 20-SVV/2018). ; |
Approved |
Most recent IF: 1.9 |
|
|
Call Number |
UA @ admin @ c:irua:148803 |
Serial |
5831 |
|
Permanent link to this record |
|
|
|
|
Author |
Kuckova, S.; Hamidi-Asl, E.; Matulkova, I.; Hynek, R.; De Wael, K.; Sanyova, J.; Janssens, K. |
|
|
Title |
Technoques and applications of Surface-Enhanced Raman Scattering Spectroscopy (SERSS) focused on cultural heritage |
Type |
A1 Journal article |
|
Year |
2018 |
Publication |
Chemické listy |
Abbreviated Journal |
Chem Listy |
|
|
Volume |
112 |
Issue |
5 |
Pages |
312-316 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The review is devoted to a modern method of vibrational spectroscopy – surface enhanced Raman spectroscopy Its principle and some of its special variants (imunnoSERS and TERS (Tip-Enhanced Raman Spectroscopy)) are described m a simpinified manner Wide application possibilities are demonstrated on selected examples from its application m culturinl heritage. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0009-2770; 1213-7103 |
ISBN |
|
Additional Links |
UA library record; WoS full record |
|
|
Impact Factor |
0.387 |
Times cited |
|
Open Access |
|
|
|
Notes |
; ; |
Approved |
Most recent IF: 0.387 |
|
|
Call Number |
UA @ admin @ c:irua:151616 |
Serial |
5869 |
|
Permanent link to this record |
|
|
|
|
Author |
Hamidi-Asl, E.; Dardenne, F.; Pilehvar, S.; Blust, R.; De Wael, K. |
|
|
Title |
Unique properties of core shell Ag@Au nanoparticles for the aptasensing of bacterial cells |
Type |
A1 Journal article |
|
Year |
2016 |
Publication |
Chemosensors |
Abbreviated Journal |
|
|
|
Volume |
4 |
Issue |
3 |
Pages |
16 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
In this article, it is shown that the efficiency of an electrochemical aptasensing device is influenced by the use of different nanoparticles (NPs) such as gold nanoparticles (Au), silver nanoparticles (Ag), hollow gold nanospheres (HGN), hollow silver nanospheres (HSN), silvergold core shell (Ag@Au), goldsilver core shell (Au@Ag), and silvergold alloy nanoparticles (Ag/Au). Among these nanomaterials, Ag@Au core shell NPs are advantageous for aptasensing applications because the core improves the physical properties and the shell provides chemical stability and biocompatibility for the immobilization of aptamers. Self-assembly of the NPs on a cysteamine film at the surface of a carbon paste electrode is followed by the immobilization of thiolated aptamers at these nanoframes. The nanostructured (Ag@Au) aptadevice for Escherichia coli as a target shows four times better performance in comparison to the response obtained at an aptamer modified planar gold electrode. A comparison with other (core shell) NPs is performed by cyclic voltammetry and differential pulse voltammetry. Also, the selectivity of the aptasensor is investigated using other kinds of bacteria. The synthesized NPs and the morphology of the modified electrode are characterized by UV-Vis absorption spectroscopy, scanning electron microscopy, energy dispersive X-ray analysis, and electrochemical impedance spectroscopy. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000382480000006 |
Publication Date |
2016-08-29 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2227-9040 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
9 |
Open Access |
|
|
|
Notes |
; Ezat Hamidi-Asl was financially supported by Belspo (University of Antwerp). The authors are thankful to Femke De Croock for her technical support and to Stanislav Trashin for his worthwhile comments on the manuscript. ; |
Approved |
Most recent IF: NA |
|
|
Call Number |
UA @ admin @ c:irua:135411 |
Serial |
5886 |
|
Permanent link to this record |
|
|
|
|
Author |
Hamidi-Asl, E.; Dardenne, F.; Blust, R.; De Wael, K. |
|
|
Title |
An improved electrochemical aptasensor for chloramphenicol detection based on aptamer incorporated gelatine |
Type |
A1 Journal article |
|
Year |
2015 |
Publication |
Sensors |
Abbreviated Journal |
Sensors-Basel |
|
|
Volume |
15 |
Issue |
4 |
Pages |
7605-7618 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Because of the biocompatible properties of gelatine and the good affinity of aptamers for their targets, the combination of aptamer and gelatine type B is reported as promising for the development of biosensing devices. Here, an aptamer for chloramphenicol (CAP) is mixed with different types of gelatine and dropped on the surface of disposable gold screen printed electrodes. The signal of the CAP reduction is investigated using differential pulse voltammetry. The diagnostic performance of the sensor is described and a detection limit of 1.83 x 10(-10) M is found. The selectivity and the stability of the aptasensor are studied and compared to those of other CAP sensors described in literature. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000354236100025 |
Publication Date |
2015-03-27 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1424-8220 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
2.677 |
Times cited |
21 |
Open Access |
|
|
|
Notes |
; Ezat Hamidi-Asl was financially supported by IOF-POC (University of Antwerp). ; |
Approved |
Most recent IF: 2.677; 2015 IF: 2.245 |
|
|
Call Number |
UA @ admin @ c:irua:126071 |
Serial |
5464 |
|
Permanent link to this record |
|
|
|
|
Author |
Daems, D.; van Nuijs, A.L.N.; Covaci, A.; Hamidi-Asl, E.; Van Camp, G.; Nagels, L.J. |
|
|
Title |
Potentiometric detection in UPLC as an easy alternative to determine cocaine in biological samples |
Type |
A1 Journal article |
|
Year |
2015 |
Publication |
Biomedical chromatography |
Abbreviated Journal |
|
|
|
Volume |
29 |
Issue |
7 |
Pages |
1124-1129 |
|
|
Keywords |
A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre |
|
|
Abstract |
The analytical methods which are often used for the determination of cocaine in complex biological matrices are a prescreening immunoassay and confirmation by chromatography combined with mass spectrometry. We suggest an ultra-high-pressure liquid chromatography combined with a potentiometric detector, as a fast and practical method to detect and quantify cocaine in biological samples. An adsorption/desorption model was used to investigate the usefulness of the potentiometric detector to determine cocaine in complex matrices. Detection limits of 6.3ngmL(-1) were obtained in plasma and urine, which is below the maximum residue limit (MRL) of 25ngmL(-1). A set of seven plasma samples and 10 urine samples were classified identically by both methods as exceeding the MRL or being inferior to it. The results obtained with the UPLC/potentiometric detection method were compared with the results obtained with the UPLC/MS method for samples spiked with varying cocaine concentrations. The intraclass correlation coefficient was 0.997 for serum (n =7) and 0.977 for urine (n =8). As liquid chromatography is an established technique, and as potentiometry is very simple and cost-effective in terms of equipment, we believe that this method is potentially easy, inexpensive, fast and reliable. Copyright (c) 2014 John Wiley & Sons, Ltd. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000356694000020 |
Publication Date |
2014-12-16 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0269-3879 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:127069 |
Serial |
8396 |
|
Permanent link to this record |
|
|
|
|
Author |
Hamidi-Asl, E.; Daems, D.; De Wael, K.; Van Camp, G.; Nagels, L.J. |
|
|
Title |
Concentration related response potentiometric titrations to study the interaction of small molecules with large biomolecules |
Type |
A1 Journal article |
|
Year |
2014 |
Publication |
Analytical chemistry |
Abbreviated Journal |
Anal Chem |
|
|
Volume |
86 |
Issue |
24 |
Pages |
12243-12249 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
In the present article, the utility of a special potentiometric titration approach for recognition and calculation of biomolecule/small molecule interactions is reported. This approach is fast, sensitive, reproducible and inexpensive in comparison to the other methods for the determination of the association constant values (Ka) and the interaction energies (ΔG). The potentiometric titration measurement is based on the use of a classical polymeric membrane indicator electrode in a solution of the small molecule ligand. The biomolecule is used as a titrant. The potential is measured versus a reference electrode and transformed to a concentration related signal over the entire concentration interval, also at low concentrations, where the mV (y-axis) versus logcanalyte (x-axis) potentiometric calibration curve is not linear. In the procedure, the Ka is calculated for the interaction of cocaine with a cocaine binding aptamer and with an anti-cocaine antibody. To study the selectivity and cross-reactivity, other oligonucleotides and aptamers are tested, as well as other small ligand molecules such as tetrakis (4-chlorophenyl)borate, metergoline, lidocaine, and bromhexine. The calculated Ka compared favorably to the value reported in the literature using SPR. The potentiometric titration approach called Concentration related Response Potentiometry, is used to study molecular interaction for 7 macromolecular target molecules and 4 small molecule ligands. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000346683900048 |
Publication Date |
2014-11-13 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2700; 5206-882x |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
6.32 |
Times cited |
10 |
Open Access |
|
|
|
Notes |
; Financial support for this work was provided by the University of Antwerp by granting L.J.N., K.D.W, G.V.C., and Ronny Blust a POC interdisciplinary research project. ; |
Approved |
Most recent IF: 6.32; 2014 IF: 5.636 |
|
|
Call Number |
UA @ admin @ c:irua:120164 |
Serial |
5548 |
|
Permanent link to this record |