toggle visibility
Search within Results:
Display Options:

Select All    Deselect All
 |   | 
Details
   print
  Record Links
Author Parrilla, M.; Claes, N.; Toyos-Rodríguez, C.; Dricot, C.E.M.K.; Steijlen, A.; Lebeer, S.; Bals, S.; De Wael, K. pdf  doi
openurl 
  Title Wearable 3D-printed solid microneedle voltammetric sensors based on nanostructured gold for uric acid monitoring Type A1 Journal article
  Year (down) 2025 Publication Biosensors and bioelectronics Abbreviated Journal  
  Volume 289 Issue Pages 117934-12  
  Keywords A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT); Antwerp engineering, PhotoElectroChemistry & Sensing (A-PECS)  
  Abstract Microneedle-based electrochemical sensors (MES) are developed as interface systems between the sensor and interstitial fluid (ISF), allowing the transdermal monitoring of analytes with clinical value. However, the widespread adoption of MES platforms to enable advances in devices for health monitoring is still a challenge. Herein, we propose an affordable and versatile wearable patch based on 3D-printed microneedle arrays to facilitate the development of electrochemical sensors. A plug-in design with a three-electrode setup allows a rapid configuration as a voltammetric sensor. Sputtering is employed to fabricate microneedle array electrodes based on nanostructured gold. The material highlights the excellent electrochemical performance due to the nanostructured surface and provides antibiofouling capability against protein. The ability of the MES to penetrate porcine skin without damage is successfully demonstrated, showing a decrease in the signal of only 8.4 % after four insertions. Thereafter, the analytical characterization for uric acid (UA) is completed in buffer solution, protein-enriched solution, emulated ISF, and in an ex vivo setup (slope 9.2 nA mu M-1), showing remarkable performance within the physiological range of UA (150-500 mu M) and excellent reversibility while pierced in porcine skin (<3.3 % difference between upwards and downwards calibrations). Finally, a preliminary on-body test shows the capability of the MES to pierce the skin, proving the robustness of the wearable patch for on-body analysis and exhibiting a 5.8 % difference in the signal before and after the test. The results demonstrated a versatile microneedle-based electrochemical cell utilizing nanostructured gold, enabling the rapid development of innovative electrochemical sensors for ISF monitoring.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos WOS:001567935400001 Publication Date 2025-08-29  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0956-5663 ISBN Additional Links UA library record; WoS full record  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:217263 Serial 9471  