toggle visibility
Search within Results:
Display Options:

Select All    Deselect All
 |   | 
Details
   print
  Record Links
Author Bencs, L.; Spolnik, Z.; Worobiec, A.; Samek, L.; Jutte, B.A.H.G.; Van Grieken, R. pdf  doi
openurl 
  Title Effects of IR heating on distribution and transport of gaseous air pollutants in urban and mountain churches in Poland Type A1 Journal article
  Year (down) 2019 Publication Journal of cultural heritage Abbreviated Journal  
  Volume 36 Issue Pages 200-209  
  Keywords A1 Journal article; Art; History; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)  
  Abstract The spatial distribution and temporal concentration variation of a set of gaseous air components (e.g., CO2, CO, H2CO, H2O) have been monitored with a multi-channel photoacoustic gas-analyzer in an urban church ( Saint Catherine's, Cracow) and a mountain church ( Saint Michaels Archangel, Szalowa) of Poland, in order to assess the likely effects of air pollution indoors under the influence of provisory electrical infrared (IR) heaters and without heating. Likewise, the ventilation characteristic and the leakage of these buildings with different constructions (i.e., plastered stone and wooden structures) with the assistance of decay curves of SF6 tracer gas was evaluated and compared. The wooden building in Szalowa, due to its more open structure, developed about one order higher ventilation rates (e.g., 0.9-1.3 h(-1)) than the stone church in Cracow (e.g., 0.1 h(-1)). The IR-heating affected only modestly the ventilation rate of the wooden church (e.g., 1.2-1.6 h(-1)), but it increased significantly that of the plastered stone church (e.g., 0.27 h(-1)). The ventilation rates were also assessed with the use of the CO2 curve decay method, and satisfactory agreement was found with those observed by the use of SF6 tracer. The spatial distribution of the studied gaseous pollutants (CO2, H2O) was found to be in some occasions nonhomogeneous in both buildings, due to the active usage of the IR-heating, especially, during a couple of consecutive liturgical services. Besides the pollution events due to ingress of gaseous air pollutants, present at enhanced levels outdoors, increased CO, CO2 and H2CO peaks were observed indoors too, which, in most cases, could be associated with incense burning. (C) 2018 Elsevier Masson SAS. All rights reserved.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000460311800021 Publication Date 2018-10-06  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1296-2074 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:158579 Serial 7847  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: